ATCH 7. Attachment to 02 82 00 Hazardous Materials Survey Technical Memo 212 South Douglas.pdf
PDF 7 MB Posted
- Solicitation number
- W9128F21B0012
About this file
This hazardous materials survey technical memorandum documents the findings of an asbestos and hazardous materials survey conducted at a residential property located at 212 South Douglas Street in Randolph, Nebraska in support of the Middle Logan Creek Flood Risk Management Project. The survey identified asbestos-containing wall and ceiling plaster throughout the main house, and asbestos-containing floor tiles and associated black mastic in some areas. Other hazardous materials identified include lead-based paint throughout the structures. The memorandum provides details on the sampling methodology and locations of identified hazardous materials.
The federal contract opportunity is for phase two of the Middle Logan Creek Flood Risk Management Project in Randolph, Nebraska. Services required include earthwork and grading for a widened and realigned Middle Logan Creek channel, bridge removals and replacements, roadway realignments, installation of storm drainage structures and utilities, erosion control measures, and construction of access roads and fences. The pre-bid site visit will be held on July 27, 2021. The solicitation number is W9128F21B0012 and was issued by the U.S. Army Corps of Engineers Omaha District.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Hazardous Materials Report Residential Property
HAZMAT Building Surveys Middle Logan Creek Contract: W9128F-18-D-0054 Flood Risk Management Project Task Order No. W9128F2F0124 Randolph, NE
Date: 09 August, 2021
To: United States Army Corps of Engineers – Omaha District
CENWO USACE
1616 Capital Avenue Omaha Nebraska 68102-4901
Attention: Sarah Miller and Brandon Sellers
From: Troy Pfertsh
Subject: HAZMAT Building Surveys Middle Logan Creek Flood Risk Management Project, Randolph Nebraska.
Sustainment and Restoration Services LLC (SRS), and our contractor, Atlas Technical, has prepared this Hazardous Materials (HAZMAT) Survey Technical Memorandum detailing the findings and conclusions from the survey which was conducted for the property located at 212 South Douglas Street, Randolph Nebraska.
INTRODUCTION
SRS and our contractor ATC performed the survey of the Residential property located at 212 S Douglas Street, Randolph, Nebraska. The survey evaluated for the type, location and quantity of asbestos containing materials (ACM), lead base paint (LBP), polychlorinated biphenyl (PCB) building materials, and other hazardous materials that may be present on the property.
The property inspected contained a single-story structure with basement constructed in the early to mid-1900’s. The structure is constructed with a brick and concrete foundation and wood framed interior with asphalt shingled roof and wood siding. Interior finishes include plaster on wood lathe and updated gypsum wall panels (drywall). Flooring materials include wood flooring covered with carpet and vinyl floor tile with associated mastic. Asbestos pipe insulation is located in the basement for the HVAC system. The basement is unfinished. There are multiple outbuildings on the property including a garage, multiple sheds and a pole barn with a metal roof. There is a significant quantity of yard waste including old tires, mechanical parts, wood scraps, general trash, and salvaged vehicles.
Asbestos Testing
A total of eighty-three bulk samples (83) of suspect ACMs were collected from the building. Based on the PLM results, the following building materials analyzed were found to contain asbestos concentrations greater than one percent (>1%).
• Samples 016, 017, 018, 019, and 020. Wall and Ceiling Plaster, 2-3% Chrysotile, located throughout the main house (~3,200 SF).
• Samples 027, 028, and 029. 9” x 9” Floor Tile with Black Adhesive, 2%-3% Chrysotile in the Floor Tile only (associated adhesive is <1% Chrysotile). Floor Tile is located in the main bathroom (40 SF).
• Samples 030, 031, and 032. Window Glazing, 2% Chrysotile, located on the main porch windows (20 LF).
• Samples 033, 034, and 035. Door Window Glazing, 2% Chrysotile, located on the window of main porch door (10 FL).
• Samples 036, 037, and 038. Pipe Insulation (Air Cell), 30% Chrysotile, located in the basement (20 LF).
• Samples 038, 040, and 041. Pipe Insulation Wrap (on joints), 40% Chrysotile, located in the basement (50 LF).
• Samples 057, 058, and 059. Roof Flashing, 0-2% Chrysotile, located on around roof penetrations (20 SF).
The following list of building materials analyzed were found to contain asbestos concentrations less than one percent (<1%):
Building Materials Less than 1%
• Samples 045, 046, and 046. Door Window Glazing, located on the breezeway door exterior.
• Samples 027, 028, and 029. Adhesive for floor tile, located in the main bathroom.
Lead Testing A total of seven (7) paint chip samples were collected for analysis of lead in representative painted surface coatings. Lead was detected in all seven samples submitted with five (5) samples reported to be above 0.5% lead by weight. Laboratory analysis was completed using Flame AAS, method SW 846 3050B/7000B. A complete list of results is included in section 3.0.
PCB Testing A total of two (2) paint chip samples were collected for analysis for PCBs. Interior paint was found to contain 3 parts per million (ppm) total PCBs and the exterior paint was found non-detect for PCBs. A complete description of the results is included in Section 4.0.
Hazardous Waste & Universal Waste Survey An inventory of the household hazardous waste identified on the property was developed during the assessment. Based on the inventory generated during the inspection of the property, multiple household hazardous wastes are present and must be removed and disposed of properly according to all local, state, and federal guidelines.
The materials identified included chemicals, compounds and gases (both organic and inorganic) that may exist in the interior and exterior of the structure. Examples identified at the property include, but are not limited to: cleaning supplies, paints, solvents, hydrocarbon-based materials, chlorofluorocarbon (CFC) refrigerants, and propane. The inventory also included fluorescent, mercury capsule thermostats; and polychlorinated biphenyls (PCB)–containing ballasts. A complete inventory is provided in Section 5.0.
Technical Memorandum
ATTACHEMENT 1
ATC Assessment results 212 South Douglas Street
11117 Mockingbird Drive
Omaha, NE 68137
July 27, 2021
HAZARDOUS MATERIALS REPORT
Residential Building 212 South Douglas Street
Randolph, Nebraska 68771
ATC PROJECT NO. 204BS04057
Prepared for:
Sustainment & Restoration Services, LLC
1033 North Mayfair Road, Suite 201
Milwaukee, WI 53226
Prepared by:
ATLAS TECHNICAL
July 27, 2021
James R. Griffin Sustainment & Restoration Services, LLC 1033 North Mayfair Road, Suite 201 Milwaukee, WI 53226
Re: Hazardous Materials Survey Report
212 South Douglas Street
ATC Project Number 204BS04057
Dear Mr. Griffin:
ATC Group Services LLC (ATC) has completed the hazardous materials survey of the referenced building. Our findings and conclusions are included herein.
We appreciate the opportunity to be of service to you on this project. If you have questions or comments regarding the information presented in this report, please contact us at (402) 697-9747.
Sincerely, ATC Group Services LLC
Tony Colby Johnny Thor Sr. Project Manager Environmental Scientist ATC Group Services LLC ATC Group Services LLC Email: tony.colby@oneatlas.com Email: johnny.thor@oneatlas.com mailto:tony.colby@oneatlas.com mailto:johnny.thor@oneatlas.com
This Page Intentionally Left Blank
TABLE OF CONTENTS
LETTER OF TRANSMITTAL ........................................................................................................... i
1.0 BUILDING DESCRIPTION
2.0 ASBESTOS SAMPLING AND RESULTS
3.0 LEAD PAINT CHIP SAMPLING AND RESULTS
4.0 PCB SAMPLING AND RESULTS
5.0 HAZARDOUS AND UNIVERSAL WASTE INVENTORY
6.0 LIMITATIONS
LIST OF TABLES
Table 2.1 Asbestos Bulk Sample Results Table 3.1 Lead Based Paint Sample Results Table 4.1 PCB Sample Results Table 5.1 Universal and Hazardous Waste Inventory
APPENDICES
Appendix A Certifications and Licenses Appendix B PLM Laboratory Analysis Report & Chain of Custody Appendix C Lead Paint Laboratory Analysis Report & Chain of Custody Appendix D PCB Laboratory Analysis Report & Chain of Custody Appendix E Sample & Material Location Sketches Appendix F Project Photographs
INTRODUCTION
ATC performed a hazardous materials survey of the Residential Property located at 212 S. Douglas Street, Randolph, Nebraska. The purpose of this survey and report is to assist Sustainment & Restoration Services, LLC with regulatory compliance in preparation of demolition of the property.
1.0 BUILDING DESCRIPTION
The property inspected contained a single-story structure with a basement constructed in the early to mid-1900’s. The structure is constructed with a brick and concrete foundation and wood framed interior with asphalt shingled roof and wood siding. Interior finish include plaster on wood lathe and some updated gypsum wall board (drywall). Flooring materials include wood flooring covered with carpet and vinyl floor tile with associated mastic. Asbestos pipe insulation is located in the basement for the HVAC system. The basement is unfinished. There are multiple outbuildings on the property including a garage, multiple sheds and a pole barn with a metal roof. There is a significant quantity of yard waste including old tires, mechanical parts, wood scraps, general trash, and salvaged vehicles.
2.0 ASBESTOS SAMPLING AND RESULTS
Tony Colby and Johnny Thor of ATC conducted the survey on July 8, 2021. Copies of their accreditation certificates and licenses are provided in Appendix A. Bulk sample analysis was performed by EMSL Analytical Inc. located in Cinnaminson, New Jersey. Bulk samples were analyzed by PLM / Dispersion Staining (DS) using the USEPA's Test Method: Method for the Determination of Asbestos in Building Materials (EPA 600/R-93/116). The laboratory is accredited under the National Institute of Standards and Technology's (NIST) National Voluntary Laboratory Accreditation Program (NVLAP Lab Code 101048-0). The laboratory analysis report and chain-of-custody forms are provided in Appendix B. Sample locations sketches are included in Appendix E and photographs are included in Appendix F. A complete list of all samples collected is provided in Table 2.1.
The following building materials analyzed were found to contain asbestos concentrations greater than one percent (>1%).
• Samples 016, 017, 018, 019, and 020. Wall and Ceiling Plaster, 2-3% Chrysotile, located throughout the Residential Property Building (~3,200 SF).
• Samples 027, 028, and 029. 9” x 9” Floor Tile with Black Adhesive, 2%-3% Chrysotile in the Floor Tile only (associated adhesive is <1% Chrysotile). Floor Tile is located in the main bathroom (40 SF).
• Samples 030, 031, and 032. Window Glazing, 2% Chrysotile, located on the main porch windows (20 LF).
• Samples 033, 034, and 035. Door Window Glazing, 2% Chrysotile, located on the window of main porch door (10 FL).
• Samples 036, 037, and 038. Pipe Insulation (Air Cell), 30% Chrysotile, located in the basement (20 LF).
• Samples 038, 040, and 041. Pipe Insulation Wrap (on joints), 40% Chrysotile, located in the basement (50 LF).
• Samples 057, 058, and 059. Roof Flashing, 0-2% Chrysotile, located on around roof penetrations (20 SF).
The following list of building materials analyzed were found to contain asbestos concentrations less than one percent (<1%)
Building Materials Less than 1%
• Samples 045, 046, and 046. Door Window Glazing, located on the breezeway door exterior.
• Samples 027, 028, and 029. Adhesive for floor tile, located in the main bathroom.
A total of eighty-three bulk samples (83) of suspect ACMs were collected from the building. Table
2.1 presents a summary of laboratory analysis and condition assessments of the sampled suspect ACMs.
Table 2.1: SUSPECT ASBESTOS BUILDING MATERIALS
Sample Number
Material Description
Material Location
% ACM Estimated
Quantity
001-003
Drywall & Joint Compound
Throughout House
ND
500 SF
004-006
12” x 12” Floor Tile with Clear Adhesive
Kitchen
ND
200 SF
007-009 Red Sheet Flooring Living Room ND 60 SF
010-012 Tan Sheet Flooring Living Room ND 10 SF
013-015 2’ x 4’ Ceiling Tile Living Room, Laundry Room, Hallway ND 900 SF
016-020 Plaster Throughout House 2%-3% Chrysotile 3,200 sf
021-023 Fiber Board Bathroom ND 160 SF
024-026 Multi-Color Sheet Flooring Hallway ND 100 SF
027-029
9” x 9” Floor Tile with
Black Adhesive
Bathroom
2%-3% Chrysotile (Floor
Tile)
<1% Chrysotile
40 SF
030-032 Window Glazing Porch Windows 2% Chrysotile 20 LF
033-035 Door Window Glazing Front Door Window 2% Chrysotile 10 LF
036-038 TSI - Air Cell Basement 30% Chrysotile 20 LF
Table 2.1: SUSPECT ASBESTOS BUILDING MATERIALS
Sample Number
Material Description
Material Location
% ACM Estimated
Quantity
039-041 TSI - Pipe Wrap Basement 40% Chrysotile 50 LF
042-044 12” x 12” Floor Tile with Brown Adhesive Breezeway ND 180 SF
045-047 Door Window Glazing Breezeway Door <1% Chrysotile 10 LF
048-050 Exterior Window Glazing Breezeway Windows ND 80 LF
051-053 Insulation Basement, Wood Burning Stove ND 10 SF
054-056 Felt Paper (Siding) Beneath Vinyl Siding ND 200 SF
057-059 Flashing Roof Penetrations <1% - 3% Chrysotile 20 SF
060-062 Grey Roof Shingle Roof ND 1,000 SF
063-065 Brown Roof Shingle Roof ND 600 SF
066-068 Felt Paper (Roof) Roof ND 150 SF
069-071 Grey Roof Shingle Roof, Large Shed ND 150 SF
072-074 Silver Roof Shingle (Bottom Layer) Roof, Small Shed ND 100 SF
075-077 Red Roof Shingle (Top Layer) Roof, Small Shed ND 100 SF
078-080 Grey Roof Shingle (Top Layer) Roof, Hay Storage Barn ND 400 SF
081-083 Red Roof Shingle (Bottom
Layer) Roof, Hay Storage Barn ND 400 SF
Notes:
ACM = Asbestos-Containing Material (>1% Chrysotile) NA = Not Applicable ND = None Detected SF = Square Feet LF = Linear Feet
Additional ACM may be present at the site in inaccessible or concealed spaces. These spaces include, but are not limited to, pipe chases, spaces between wall/ceiling/door/floor cavities, interior of mechanical components such as boiler cavities, interior ducts, beneath foundation pads, etc.
Unidentified suspect materials should be treated as assumed ACM in accordance with 40 CFR 763.
Quantity provided in Table 2.1 is estimated by the inspector based on visible ACM. Additional pipe insulation may be hidden within call chases or cavities.
3.0 LEAD PAINT CHIP SAMPLING AND RESULTS
EMSL Analytical, Inc. located in Cinnaminson, New Jersey, conducted analysis on the paint chip samples to determine lead concentrations. The American Industrial Hygiene Association (AIHA) Laboratory Accreditation Program accredits EMSL for lead paint analysis. The laboratory report detailing the findings is provided in Appendix B.
Mr. Tony Colby performed the sampling of the Residential Property on July 8, 2021. Seven (7) paint chips were collected from the Residential Property that may be impacted by renovation or demolition work.
A material is considered by the US EPA to be lead-based paint (LBP) if analysis indicates more than 0.5% by weight of lead in paint (or 1.0 mg\cm2 or 5,000 ppm). A material is considered lead-containing paint (LCP) if lead is present in any concentration above the laboratory limit of detection
(LOD).
The complete list of the results of the lead survey are presented in Table 3.1 below:
Table 3.1: Lead Paint Survey Results
Sample # Color Sample Location Structure / Member Substrate Concentration % by Weight
01 White Interior Wall Plaster 0.015% 02 Tan Interior Window Casing Wood 0.32% 03 White Interior Doors Door Wood 0.81% 04 White Interior Doors Door Frame Wood 0.87% 05 Tan Exterior (front) Porch Ceiling Wood 13% 06 White Exterior Siding Wood 17% 07 Brown Exterior (side) Porch Trim Wood 18%
* Sample result below the detectable reporting limit.
Detection limit is <0.0008%
4.0 PCB SAMPLING AND RESULTS
Samples for PCBs were collected using hand tools (i.e. utility knife, screwdriver, hammer, pliers, chisel, etc.) that were decontaminated or discarded after one-time usage (i.e. utility blades) and delivered to Con-Test Analytical Laboratory of East Longmeadow, Massachusetts under standard chain of custody (COC) procedures. Samples were extracted using US EPA Method 3540C (Soxhlet extraction) and analyzed for PCBs using US EPA Method 8082. The laboratory analysis report and chain-of-custody forms are provided in Appendix D. A summary of the data is provided in Table 4.1 below. Sample locations sketches are included in Appendix E. Sample location photographs are included with the asbestos photographs in Appendix F.
Table 4.1: PCB Sealant Survey Summary
Sample ID
Sample Material
Material Location Total PCBs
PPM (RL)
PCB Type
(Concentration)
Paint
Interior
0.74 1.9
(RL = 0.43)
Aroclor-1248 Aroclor-1254
Paint
Exterior Non-Detect
(RL = 0.45)
N/A
Notes N/A = Not Applicable RL = Laboratory Reporting Limit
5.0 HAZARDOUS AND UNIVERSAL WASTE INVENTORY
A summary of the miscellaneous hazardous and universal waste inventory is presented in the table below. The items identified below were accessible; labels were missing and some assumptions were made at the judgment of the inspector. Additional containers are presumed to be hidden or covered over piles of tires, debris and overgrowth. All universal waste and hazardous materials are to be taken from the property prior to demolition for proper recycling (if not re-used by the Owner) and disposal.
Table 5.1 Hazardous & Universal Waste Inventory
Item Approximate Quantity Field Notes
Thermostat ampules (mercury) 1 House: living room wall
Coolers / refrigerants (CFCs) 1 House: kitchen
HVAC unit (CFCs) 1 Exterior: west side of house
Light ballast (PCBs) 16 Garage & 1 loose in shed
4’ Fluorescent lights (mercury) 30 Garage
Roof patch, 5 gallon 1 Shed: exterior
Drywall mud buckets, 5 gallon 3 Shed & house
Latex or Oil-Based Paint, 1 gallon containers 10 Basement, garage/sheds.
Many labels are missing.
Various household cleaners (Windex, Clorox, Armor All, etc.) 10+ Throughout garage & house; partially used/empty, many labels missing.
Lacquer paint thinner, 1 gallon 2 Garage
Motor oil, 1 quart 7 Garage: partially empty
Coolant (auto), 1 gallon 2 Garage: partially empty
Gas container, 5 gallon 2 Garage & shed: empty
Abandoned lawn mowers, oil & gas
2 Abandoned around property (lawn boy push & riding style)
Abandoned snow blower, potential oil & gas 1 Pole barn
Abandoned vehicles, potential fuel, oil, fluids
2 trucks 1 tractor Pole barn, abandoned vehicles
Generator with potential oil/gas fuel 1 Shed, abandoned
Trailer with hydraulic pump 1 Abandoned by shed, may contain hydraulic fluid in pump.
Empty 55 Gallon Drums 4 Unreadable labels, appear empty.
Located sheds & around yard.
Golf Cart Battery (lead-acid style) 1 Abandoned in shed, limited access
Table 5.1 Hazardous & Universal Waste Inventory
Item Approximate Quantity Field Notes
Butane camping fuel (grill style) 4 Garage: Appears empty
Propane tanks (grill style) 3 Garage: Appears empty
Propane tank, large 2 Outside on lawn, disconnected & appears empty
Tires 50+ Scattered around property
6.0 LIMITATIONS
This report is intended for the sole use of Sustainment & Restoration Services, LLC. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or re-use of this document or the findings, conclusions, or recommendations is at the risk of said user. ATC’s selection of sample locations and frequency of sampling was based on ATC’s observations and the assumption that like materials in the same area are homogeneous in content. Unsampled suspect asbestos materials should be treated as assumed ACM in accordance with 40 CFR 763.
For paint and PCB sampling, ATC’s selection of sample locations and frequency of sampling was based on the inspector’s assumption that like materials in the same area are homogeneous in content. Materials that could not be visually identified on the surface were not inspected and would not be noted in this report.
This report is not intended to serve as a bidding document or as a project specification document.
Actual site conditions may change over time and quantities are general estimates and should be field verified prior to making cost assumptions. The scope of services performed in execution of this evaluation may not be appropriate to satisfy the needs of other users, and use or reuse of this document or the findings or conclusions herein is at the risk of said user. Although reasonable efforts have been made to identify suspect hazardous materials in the areas identified, the limits of the scope of work and inspection technique used is inherently limited in the sense that only full demolition procedures will reveal all building materials of a structure.
Our professional services have been performed, our findings obtained, and our conclusions and recommendations prepared in accordance with customary principles and practices in the fields of environmental science and engineering. This statement is in lieu of other statements either expressed or implied. This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated. The results, findings and conclusions expressed in this report are based only on conditions that were observed during ATC's inspection of the Site.
APPENDIX A
ATC Certifications and Licenses
State of Nebraska Department of Health and Human Services
Division of Public Health
Tony J Colby
Asbestos Inspector
License #: 740 Status: Active
Expiration: 08/11/2021
Tony J Colby
Lead Abatement Risk Assessor
License #: 219
Expiration: 06/11/2022
Johnny Vong Thor
Asbestos Inspector
License #: 1317
Expiration: 05/22/2023
APPENDIX B
PLM Laboratory Analysis Report & Chain of Custody
EMSL Order: 042117015 EMSL Analytical, Inc.
200 Route 130 North Cinnaminson, NJ 08077
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Attention: Tim Jacobsen Phone: (402) 320-8396 ATC Group Services LLC Fax: (402) 597-8532 11117 Mockingbird Drive Received Date: 07/13/2021 8:40 AM Omaha, NE 68137 Analysis Date: 07/15/2021 - 07/21/2021
Project: 204BS04057 - 212 Douglas St
Collected Date: 07/08/2021
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Non-Asbestos Asbestos Sample Description Appearance % Fibrous % Non-Fibrous % Type
001-Drywall
042117015-0001
1- Joint Compound
042117015-0001A
002-Drywall
042117015-0002
2- Joint Compound
042117015-0002A
003-Drywall
042117015-0003
3- Joint Compound
042117015-0003A
4- Floor Tile
042117015-0004
004-Adhesive
042117015-0004A
5- Floor Tile
042117015-0005
005-Adhesive
042117015-0005A
6- Floor Tile
042117015-0006
006-Adhesive
042117015-0006A
042117015-0007
042117015-0008
042117015-0009
042117015-0010
Kitchen - Drywall
Kitchen - Joint Compound
Kitchen - Drywall
Kitchen - Joint
Laundry Room - Drywall
Laundry Room - Joint
Kitchen - 12x12 Floor Tile
Kitchen - Clear Adhesive
Living Room - Red Sheet Flooring
Living Room - Tan
Brown/White Fibrous Heterogeneous
White Non-Fibrous Homogeneous
Brown/White Fibrous Heterogeneous
White Non-Fibrous Homogeneous
Brown/White Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
Clear Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
Clear Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
Clear Non-Fibrous Homogeneous
Red/Black Fibrous Heterogeneous
Red/Black Non-Fibrous Heterogeneous
Red/Black Fibrous Homogeneous
Tan/Black Fibrous Heterogeneous
10% Cellulose
2% Synthetic
15% Cellulose
30% Cellulose
90% Non-fibrous (Other)
98% Non-fibrous (Other)
100% Non-fibrous (Other)
85% Non-fibrous (Other)
70% Non-fibrous (Other)
None Detected
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 1 of 6
Initial report from: 07/21/2021 21:07:39 http://www.emsl.com/ mailto:cinnasblab@EMSL.com
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Non-Asbestos Asbestos
042117015-0011
042117015-0012
042117015-0013
042117015-0014
042117015-0015
016-Base Coat
042117015-0016
016-Skim Coat
042117015-0016A
042117015-0017
018-Base Coat
042117015-0018
18- Skim Coat
042117015-0018A
19- Base Coat
042117015-0019
19- Skim Coat
042117015-0019A
20- Base Coat
042117015-0020
020-Skim Coat
042117015-0020A
042117015-0021
042117015-0022
042117015-0023
042117015-0024
042117015-0025
Living Room - 2x4 Ceiling Tile
Kitchen - Plaster
Plaster
Bedroom - Plaster
Bedroom - Plaster
Bathroom Wall - Fiber Board
Hallway - Multi-color
Tan/Black Non-Fibrous Homogeneous
Tan/Black Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Brown Fibrous Homogeneous
Brown Fibrous Homogeneous
Brown Fibrous Homogeneous
Brown/Black Fibrous Heterogeneous
Brown/Black Fibrous
80% Min. Wool
90% Cellulose
60% Cellulose
90% Cellulose
20% Non-fibrous (Other)
97% Non-fibrous (Other)
10% Non-fibrous (Other)
40% Non-fibrous (Other)
10% Non-fibrous (Other)
2% Chrysotile
3% Chrysotile
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 2 of 6
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
042117015-0026
27- Floor Tile
042117015-0027
027-Adhesive
042117015-0027A
28- Floor Tile
042117015-0028
028-Adhesive
042117015-0028A
29- Floor Tile
042117015-0029
029-Adhesive
042117015-0029A
042117015-0030
042117015-0031
042117015-0032
042117015-0033
042117015-0034
042117015-0035
042117015-0036
042117015-0037
042117015-0038
042117015-0039
042117015-0040
042117015-0041
Bathroom - 9x9 Floor
Bathroom - Black
Porch Windows - Window Glazing
Front Door Window - Door Window Glazing
Basement - TSI - Air Cell
Basement - Pipe Wrap
Brown/Black Fibrous Homogeneous
Gray Non-Fibrous Homogeneous
Black Non-Fibrous Homogeneous
Gray Non-Fibrous Homogeneous
Black Non-Fibrous Homogeneous
Gray Non-Fibrous Homogeneous
Black Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
White Fibrous Homogeneous
50% Cellulose
40% Cellulose
30% Chrysotile
40% Chrysotile
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 3 of 6
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
42- Floor Tile
042117015-0042
042-Adhesive
042117015-0042A
43- Floor Tile
042117015-0043
043-Adhesive
042117015-0043A
44- Floor Tile
042117015-0044
044-Adhesive
042117015-0044A
042117015-0045
042117015-0046
042117015-0047
042117015-0048
042117015-0049
042117015-0050
042117015-0051
042117015-0052
042117015-0053
042117015-0054
042117015-0055
042117015-0056
042117015-0057
Breezeway - 12x12 Floor Tile
Breezeway - Brown
Breezeway Door -
Breezeway Window - Exterior - Window Glazing
Breezeway Window - Exterior - Window Glazing
Breezeway Window - Exterior - Window Glazing
Basement - Wood Burning Stove - Insulation
Basement - Wood Burning Stove - Insulation
Basement - Wood Burning Stove - Insulation
Beneath Vinyl Siding - Felt Paper - Siding
Roof - Penetrations - Flashing
White Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
White Non-Fibrous Homogeneous
Tan/White Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
Brown Non-Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Non-Fibrous
65% Cellulose
35% Non-fibrous (Other)
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 4 of 6
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
042117015-0058
042117015-0059
042117015-0060
042117015-0061
042117015-0062
042117015-0063
042117015-0064
042117015-0065
042117015-0066
042117015-0067
042117015-0068
042117015-0069
042117015-0070
042117015-0071
042117015-0072
042117015-0073
042117015-0074
042117015-0075
Roof - Grey Roof Shingle
Roof - Brown Roof
Roof - Felt Paper - Roof
Large Shed - Roof - Roof Shingle - Large Shed
Large Shed - Roof - Roof Shingle - Large Shed
Large Shed - Roof - Roof Shingle - Large Shed
Small Shed - Roof - Bottom Layer - Silver Roof Shingle - Small Shed
Small Shed - Roof - Bottom Layer - Silver Roof Shingle - Small Shed
Small Shed - Roof - Bottom Layer - Silver Roof Shingle - Small Shed
Small Shed - Roof - Top Layer - Red Roof Shingle - Small Shed
Black Non-Fibrous Homogeneous
Black Fibrous Homogeneous
Gray Fibrous Homogeneous
Black Fibrous Homogeneous
Gray/Black Fibrous Homogeneous
Brown Fibrous Homogeneous
Brown Fibrous Homogeneous
Brown/Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Black Fibrous Homogeneous
Gray/Black Fibrous Homogeneous
Silver Fibrous
Silver
Black/Silver
Red/Black
7% Cellulose
7% Cellulose
3% Glass
20% Glass
20% Glass
25% Glass
6% Cellulose
10% Glass
93% Non-fibrous (Other)
91% Non-fibrous (Other)
80% Non-fibrous (Other)
82% Non-fibrous (Other)
80% Non-fibrous (Other)
50% Non-fibrous (Other)
50% Non-fibrous (Other)
75% Non-fibrous (Other)
2% Mica 88% Non-fibrous (Other)
2% Mica 92% Non-fibrous (Other)
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 5 of 6
Tel/Fax: (800) 220-3675 / (856) 786-5974 http://www.EMSL.com / cinnasblab@EMSL.com
ATC55 Customer ID:
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
042117015-0076
042117015-0077
042117015-0078
042117015-0079
042117015-0080
042117015-0081
042117015-0082
042117015-0083
Small Shed - Roof - Top Layer - Red Roof Shingle - Small Shed
Small Shed - Roof - Top Layer - Red Roof Shingle - Small Shed
Hay Storage Barn - Roof - Top Layer - Grey Roof Shingle - Barn
Hay Storage Barn - Roof - Top Layer - Grey Roof Shingle - Barn
Hay Storage Barn - Roof - Top Layer - Grey Roof Shingle - Barn
Hay Storage Barn - Roof - Bottom Layer - Red Roof Shingle - Barn
Hay Storage Barn - Roof - Bottom Layer - Red Roof Shingle - Barn
Hay Storage Barn - Roof - Bottom Layer - Red Roof Shingle - Barn
Red/Black Fibrous Homogeneous
Red/Various/Black Fibrous Homogeneous
Gray
Gray
Gray/Black
25% Cellulose
25% Glass
25% Cellulose
Analyst(s)
Brian Kibelstis (64) Nancy Stalter (22) Paige Havener (13)
Samantha Rundstrom, Laboratory Manager or Other Approved Signatory
ASB_PLM_0008_0001 - 1.78 Printed: 7/21/2021 9:07 PM Page 6 of 6
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NVLAP Lab Code 101048-0, AIHA-LAP, LLC-IHLAP Lab 100194, NJ DEP 03036, PA ID# 68-00367, LA #04127
OrderID: 042117015
APPENDIX C
Lead Paint Laboratory Analysis Report & Chain of Custody
EMSL Analytical, Inc.
200 Route 130 North, Cinnaminson, NJ 08077 Phone/Fax: (856) 303-2500 / (856) 786-5974 http://www.EMSL.com cinnaminsonleadlab@emsl.com
EMSL Order:
CustomerID:
CustomerPO:
ProjectID:
202105422
ATC55
Omaha, NE 68137 Collected:
Project: 204BS04057 212 Douglas St.
Attn: Tim Jacobsen Phone: (402) 697-9747 ATC Group Services LLC Fax: (402) 597-8532
11117 Mockingbird Drive Received:
07/12/21 10:00 AM
7/8/2021
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
Client SampleDescription Collected Analyzed Weight RDL Lead Concentration
01 7/8/2021 7/15/2021 0.2495 g 0.0080 % wt 0.015 % wt 202105422-0001 Site: interior walls, plaster - white paint
02 7/8/2021 7/15/2021 0.2574 g 0.0080 % wt 0.32 % wt 202105422-0002 Site: interior window casing wood - tan paint
03 7/8/2021 7/15/2021 0.2512 g 0.040 % wt 0.81 % wt 202105422-0003 Site: interior door - wood - white paint
04 7/8/2021 7/15/2021 0.2556 g 0.040 % wt 0.87 % wt 202105422-0004 Site: interior droor frame - wood - white - paint
05 7/8/2021 7/15/2021 0.2569 g 1.6 % wt 13 % wt 202105422-0005 Site: porch - enclosed ceiling - wood tan paint
06 7/8/2021 7/15/2021 0.2541 g 1.6 % wt 17 % wt 202105422-0006 Site: exterior siding wood white paint
07 7/8/2021 7/15/2021 0.2507 g 1.6 % wt 18 % wt 202105422-0007 Site: exterior side porch wood brown paint
The sample duplicate RPD for samples -0001 through -0007 fell outside control limits. All other QC results met criteria.
Phillip Worby, Lead Laboratory Manager or other approved signatory
Test Report PB w/RDL-2.0.0.0 Printed: 7/19/2021 5:56:23 PM Page 1 of 1
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Cinnaminson, NJ NELAP Certifications: NJ 03036, NY 10872, PA 68-00367, AIHA-LAP, LLC ELLAP 100194, A2LA 2845.01
Initial report from 07/19/2021 17:56:23 mailto:cinnaminsonleadlab@emsl.com
OrderID: 202105422
OrderID: 202105422
APPENDIX D
PCB Laboratory Analysis & Chain of Custody
39 Spruce Street * East Longmeadow, MA 01028 * FAX 413/525-6405 * TEL. 413/525-2332
July 19, 2021
Tim Jacobsen ATC Group Services LLC - Nebraska
Project Location: 212 Douglas St, Randolph, NE Client Job Number:
Project Number: 204BS04057 Laboratory Work Order Number: 21G0555
Enclosed are results of analyses for samples received by the laboratory on July 27, 2021. If you have any questions concerning this report, please feel free to contact me.
Sincerely, Kaitlyn A. Feliciano Project Manager
Table of Contents Sample Summary 3
Case Narrative 4
Sample Results 5
21G0555-01 5
21G0555-02 6
Sample Preparation Information 7
QC Data 8
Polychlorinated Biphenyls with 3540 Soxhlet Extraction 8
B286088 8
Dual Column RPD Report 9
Flag/Qualifier Summary 12
Certifications 13
Chain of Custody/Sample Receipt 14
ATC Group Services LLC - Nebraska
ATTN: Tim Jacobsen
PURCHASE ORDER NUMBER:
REPORT DATE: 7/19/2021
PROJECT NUMBER: 204BS04057
ANALYTICAL SUMMARY
WORK ORDER NUMBER: 21G0555
The results of analyses performed on the following samples submitted to CON-TEST, a Pace Analytical Laboratory, are found in this report.
PROJECT LOCATION: 212 Douglas St, Randolph, NE
FIELD SAMPLE # LAB ID: MATRIX
SAMPLE DESCRIPTION
TEST
SUB LAB
1- Paint Interior, walls, doors 21G0555-01 Paint SW-846 8082A
2- Paint Exterior siding 21G0555-02 Paint SW-846 8082A
CASE NARRATIVE SUMMARY
All reported results are within defined laboratory quality control objectives unless listed below or otherwise qualified in this report.
The results of analyses reported only relate to samples submitted to Con-Test, a Pace Analytical Laboratory, for testing.
I certify that the analyses listed above, unless specifically listed as subcontracted, if any, were performed under my direction according to the approved methodologies listed in this document, and that based upon my inquiry of those individuals immediately responsible for obtaining the information, the material contained in this report is, to the best of my knowledge and belief, accurate and complete.
Lisa A. Worthington Technical Representative
Date Received: 7/13/2021
Sample Description: Work Order: 21G0555
Field Sample #: 01-Paint Interior, walls, doors
Sample ID: 21G0555-01
Sampled: 7/8/2021 00:00
Sample Matrix: Paint Polychlorinated Biphenyls with 3540 Soxhlet Extraction
Analyte
Results
RL
Units
Dilution
Flag/Qual
Method
Date Prepared
Date/Time Analyzed
Analyst
Aroclor-1016 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1221 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1232 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1242 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1248 [2] 0.74 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1254 [1] 1.9 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1260 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1262 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Aroclor-1268 [1] ND 0.43 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:42 JMB
Surrogates % Recovery Recovery Limits Flag/Qual Decachlorobiphenyl [1] 56.4 Decachlorobiphenyl [2] 46.8 Tetrachloro-m-xylene [1] 65.5 Tetrachloro-m-xylene [2] 56.7
30-150 30-150 30-150 30-150
7/18/21 16:42 7/18/21 16:42 7/18/21 16:42 7/18/21 16:42
Date Received: 7/13/2021
Sample Description: Work Order: 21G0555
Field Sample #: 02-Paint Exterior siding
Sample ID: 21G0555-02
Sampled: 7/8/2021 00:00
Sample Matrix: Paint Polychlorinated Biphenyls with 3540 Soxhlet Extraction
Results
RL
Dilution
Flag/Qual
Method
Prepared
Date/Time Analyzed
Analyst
Aroclor-1016 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1221 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1232 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1242 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1248 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1254 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1260 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1262 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Aroclor-1268 [1] ND 0.45 mg/Kg 1 SW-846 8082A 7/15/21 7/18/21 16:59 JMB
Surrogates % Recovery Recovery Limits Flag/Qual Decachlorobiphenyl [1] 95.4 Decachlorobiphenyl [2] 79.1 Tetrachloro-m-xylene [1] 86.1 Tetrachloro-m-xylene [2] 74.0
30-150 30-150 30-150 30-150
7/18/21 16:59 7/18/21 16:59 7/18/21 16:59 7/18/21 16:59
Sample Extraction Data
Prep Method: SW-846 3540C Analytical Method: SW-846 8082A
Lab Number [Field IDJ Batch Initial [gJ Final [mLJ Date
21G0555-01 [01-Paint Interior, walls, doors] 21G0555-02 [02-Paint Exterior siding]
B286088 B286088
0.235 10.0
0.222 10.0
07/15/21 07/15/21
QUALITY CONTROL
Polychlorinated Biphenyls with 3540 Soxhlet Extraction - Quality Control
Result Reporting
Limit
Spike Level
Source Result
%REC
%REC
Limits
RPD
RPD
Limit
Notes
Batch B286088 - SW-846 3540C
Blank (B286088-BLK1) Prepared: 07/15/21 Analyzed: 07/18/21 Aroclor-1016 ND 0.35 mg/Kg Aroclor-1016 [2C] ND 0.35 mg/Kg Aroclor-1221 ND 0.35 mg/Kg Aroclor-1221 [2C] ND 0.35 mg/Kg Aroclor-1232 ND 0.35 mg/Kg Aroclor-1232 [2C] ND 0.35 mg/Kg Aroclor-1242 ND 0.35 mg/Kg Aroclor-1242 [2C] ND 0.35 mg/Kg Aroclor-1248 ND 0.35 mg/Kg Aroclor-1248 [2C] ND 0.35 mg/Kg Aroclor-1254 ND 0.35 mg/Kg Aroclor-1254 [2C] ND 0.35 mg/Kg Aroclor-1260 ND 0.35 mg/Kg Aroclor-1260 [2C] ND 0.35 mg/Kg Aroclor-1262 ND 0.35 mg/Kg Aroclor-1262 [2C] ND 0.35 mg/Kg Aroclor-1268 ND 0.35 mg/Kg Aroclor-1268 [2C] ND 0.35 mg/Kg Surrogate: Decachlorobiphenyl 6.44 mg/Kg 6.91 93.2 30-150 Surrogate: Decachlorobiphenyl [2C] 5.39 mg/Kg 6.91 77.9 30-150 Surrogate: Tetrachloro-m-xylene 6.24 mg/Kg 6.91 90.3 30-150 Surrogate: Tetrachloro-m-xylene [2C] 5.41 mg/Kg 6.91 78.2 30-150
LCS (B286088-BS1) Prepared: 07/15/21 Analyzed: 07/18/21
Aroclor-1016 1.8 0.45 mg/Kg 2.25 79.3 40-140 Aroclor-1016 [2C] 1.6 0.45 mg/Kg 2.25 70.7 40-140 Aroclor-1260 1.6 0.45 mg/Kg 2.25 69.1 40-140 Aroclor-1260 [2C] 1.3 0.45 mg/Kg 2.25 59.2 40-140
Surrogate: Decachlorobiphenyl 6.33 mg/Kg 9.02 70.2 30-150 Surrogate: Decachlorobiphenyl [2C] 5.30 mg/Kg 9.02 58.8 30-150 Surrogate: Tetrachloro-m-xylene 6.72 mg/Kg 9.02 74.5 30-150 Surrogate: Tetrachloro-m-xylene [2C] 5.73 mg/Kg 9.02 63.6 30-150
LCS Dup (B286088-BSD1) Prepared: 07/15/21 Analyzed: 07/18/21
Aroclor-1016 2.1 0.44 mg/Kg 2.20 97.3 40-140 17.7 30 Aroclor-1016 [2C] 1.9 0.44 mg/Kg 2.20 85.5 40-140 16.4 30 Aroclor-1260 2.0 0.44 mg/Kg 2.20 89.4 40-140 23.0 30 Aroclor-1260 [2C] 1.7 0.44 mg/Kg 2.20 75.7 40-140 21.9 30
Surrogate: Decachlorobiphenyl 8.34 mg/Kg 8.78 95.0 30-150 Surrogate: Decachlorobiphenyl [2C] 6.96 mg/Kg 8.78 79.2 30-150 Surrogate: Tetrachloro-m-xylene 6.50 mg/Kg 8.78 74.0 30-150 Surrogate: Tetrachloro-m-xylene [2C] 5.62 mg/Kg 8.78 64.0 30-150
IDENTIFICATION SUMMARY
FOR SINGLE COMPONENT ANALYTES
SW-846 8082A
Lab Sample ID:
21G0555-01
Date(s) Analyzed:
07/18/2021 07/18/2021
Instrument ID (1): ECD5 Instrument ID (2): ECD5
GC Column (1): ID: (mm) GC Column (2): ID: (mm)
ANALYTE COL RT RT WINDOW CONCENTRATION %RPD
FROM TO
Aroclor-1248 1 0.000 0.000 0.000 0.64 2 0.000 0.000 0.000 0.74 14.5
Aroclor-1254 1 0.000 0.000 0.000 1.9 2 0.000 0.000 0.000 1.6 17.1
01-Paint Interior, walls, doors
LCS
B286088-BS1
Aroclor-1016 1 0.000 0.000 0.000 1.8 2 0.000 0.000 0.000 1.6 11.8
Aroclor-1260 1 0.000 0.000 0.000 1.6 2 0.000 0.000 0.000 1.3 20.7
B286088-BSD1
Aroclor-1016 1 0.000 0.000 0.000 2.1 2 0.000 0.000 0.000 1.9 10.0
Aroclor-1260 1 0.000 0.000 0.000 2.0 2 0.000 0.000 0.000 1.7 16.2
LCS Dup
FLAG/QUALIFIER SUMMARY
* QC result is outside of established limits.
t Wide recovery limits established for difficult compound.
Wide RPD limits established for difficult compound.
# Data exceeded client recommended or regulatory level
ND Not Detected
RL Reporting Limit is at the level of quantitation (LOQ)
DL Detection Limit is the lower limit of detection determined by the MDL study
MCL Maximum Contaminant Level
Percent recoveries and relative percent differences (RPDs) are determined by the software using values in the calculation which have not been rounded.
No results have been blank subtracted unless specified in the case narrative section.
Certified Analyses included in this Report
No certified Analyses included in this Report
Certifications
CERTIFICATIONS
Con-Test, a Pace Environmental Laboratory, operates under the following certifications and accreditations:
Code Description Number Expires
AIHA AIHA-LAP, LLC - ISO17025:2017 100033 03/1/2022
MA Massachusetts DEP M-MA100 06/30/2022
CT Connecticut Department of Publilc Health PH-0165 12/31/2022
NY New York State Department of Health 10899 NELAP 04/1/2022
NH-S New Hampshire Environmental Lab 2516 NELAP 02/5/2022
RI Rhode Island Department of Health LAO00112 12/30/2021
NC North Carolina Div. of Water Quality 652 12/31/2021
NJ New Jersey DEP MA007 NELAP 06/30/2022
FL Florida Department of Health E871027 NELAP 06/30/2022
VT Vermont Department of Health Lead Laboratory LL720741 07/30/2022
ME State of Maine MA00100 06/9/2023
VA Commonwealth of Virginia 460217 12/14/2021
NH-P New Hampshire Environmental Lab 2557 NELAP 09/6/2021
VT-DW Vermont Department of Health Drinking Water VT-255716 06/12/2022
NC-DW North Carolina Department of Health 25703 07/31/2021
PA Commonwealth of Pennsylvania DEP 68-05812 06/30/2022
MI Dept. of Env, Great Lakes, and Energy 9100 09/6/2021 i ffi 2.!t!!. J" Phooe, 413-525-2'3' JI{; oS-S} http://www.contestlabs.com
CHAIN OF CUSTODY RECORD
Doc# 381RevO58 2015
39 Spruce Street
Page-/- of/--
<:ompany Nam,e:
Fax: 413-525-6405 Email: info@contestlabs.com
ATC Grou1.2 Services LL( (NEBRASKA!
East Longmeadow, MA 01028
# of Containers
2 Preservation Code
Phone: 402-697-9747 I xuJ a:
ANALYS IS 1 REQUESTED won.ftfaiiintieiriiC&od1e
Address: 11117 Mockingbird Drive Omaha, NE 68137 I I I I Project Name: · SRS Randolph - 212 Douglas St ::c.
Project Location: 212 Douglas Street, Randolph, Nebraska
Project Number: 2048S04057
Project Manager: Tim Jacobsen Other:
".s'=
N
Con-Test Bid: Enhanced Data Package Required: LJ Invoice Reclpient: Same Email To: tim.jacobsen@atcgs.com Sampled By: Tim Jacobsen Fax To#:
02- Paint Exterior siding 7/8/2021 I 7/8/2021 ca co
0 Lab to Filter
1 Matrix Codes:
GW = Ground Water WW = Waste Water DW = Drinking Water A= Air S = Soil/Solid SL= Sludge 0 = Other {please define)
Comments:
PCBs via USEPA 8082 with Soxhlet Extraction (3540C) Please use the foUowing codes to indicate possible sample concentration
2 Preservation Codes:
I= Iced
H = HCL
M = Methanol N = Nitric Acid S = Sulfuric Acid B = Sodium Bisulfate X = Sodium Hydroxide T = Sodium Thiosulfate O = Other (please define) within the Cone Code column above:
H - High; M - Medium; L • Low; C • Clean; U - Unknown byns ure)
2£.,,\,, dl-1
Program Information 0 MCP Analytical Certlfication Form Required
0 RCP Analysis Certification Form Required
3 Container Codes:
A = Amber Glass G = Glass P = Plastic ST= Sterile V = Vial S = Summa Canister
Relinquished by: (signature) Date/Time:
Received by: (signature) Date/Time:
0 MA State DW Form Required
PWSID # - - - - - - -
NELAC and AIHA-LAP, LLC Accredited
T = Tedlar Bag 0 = Other (please define)
Relinquished by: (signature) Date/Time: TURNAROUND TIME (BUSINESS DAYS) STARTS AT 9:00 AM THE DAY AFTER SAMPLE RECEIPT UNLESS THERE ARE http://www.contestlabs.com/ http://www.contestlabs.com/ mailto:info@contestlabs.com mailto:tim.jacobsen@atcgs.com
!--------------+---------{QUESTIONS ON THIS CHAIN. IF THIS FORM IS NOT FILLED OUT COMPLETELY OR IS JNCORRECT, TURNAROUND TIME Received by: (signature) Date/Time: CANNOT START UNTIL ALL QUESTIONS HAVE BEEN ANSWERED.
PLEASE BE CAREFUL NOT TO CONTAMINATE THIS DOCUMENT
TRACK ANOTHER SHIPMENT
774236914590
ADD NICKNAME
Delivered Tuesday, July 13} 2021 at 10:23 am
DELIVERED
Signed for by: L.RJOS
GET STATUS UPDATES
OBTAIN PROOF OF DELJVERY
FROM
TO
Omaha, NEUS EAST LONGMEADOW, MA US
Travel History
TIME ZONE
Local Scan Time
Tuesday, July 13, 2021
1023AM
EAST LONGMEADOW. MA
Delivered
8:18 AM WINDSOR LOCKS, CT On FedEx vehicle for delivery
804AM WINDSOR LOCKS, CT At local FedEx facility
714AM EAST GRANBY CT Atdestination sort facility
353AM MEMPHIS, TN Departed FedEx location
Monday, July 12, 2021
10:55 PM
MEMPHIS, TN
Arrived at FedEx location
825PM OMAHA.NE Left FedEx origin facility
408PM OMAHA, NE Picked up
306PM Shipment information sent to FedEx
Sulfuric- Perchlorate Ziplock
Login Sample Receipt Checklist - (Rejection Criteria Listing - Using Acceptance Policy) Any False
Statement will bebrought to the attention of the Client - State True or False Client
Received By LL
Time io.2= How were the samples In Cooler No Cooler T On Ice No Ice T received? Direct from Sampling Ambient Melted Ice ----
Were samples within ,.- By Gun# ---- Actual Temp -_:2.._0_', °"------
Temperature? 2-6°C r By Blank# Actual Tem'p -- --------- Was Custody Seal Intact? t:,JA. Were Samples Tampered with?
Was COC Relinquished? T Does Ch in Agree With Samples?
Are there broken/leaking ose caps on any samples? --'----- Is COC in ink/ Legible? I Were samples received within holding time?
Did COC include all Client 1 Analysis T Sampler Name 'T pertinent Information? Project r ID's I Collection Dates/Times j-_ -- Are Sample labels filled out and legible? t
Are there Lab to Filters? r Are there Rushes?
Who was notified?
Who was notified?
Are there Short Holds?
Is there enough Volume?
Is there Headspace where applicable?
Proper Media/Containers Used?
Were trip blanks received?
Do all samples have the proper pH?
r t=
Who was notified?
MS/MSD? r-ls splitting samples required?
OnCOC? -,...
Acid Base
Unp- 1 Liter Amb. 1 Liter Plastic 16 ozAmb.
HCL- 500 ml Amb. 500 ml Plastic 8oz Amb/Clear Meoh- 250 ml Amb. 250 ml Plastic 4oz Amb/Clear Bisulfate- Flashpoint Col./Bacteria 2oz Amb/Clear 01- Other Glass Other Plastic Encore T--hio-su-lf-ate-- ----+---S-O-C -Kit-----------Pl-as-tic-B'a '------- Frozen:
Unp-
HCL-
1 Liter Amb.
500 ml Amb.
1 Liter Plastic 500 ml Plastic
16ozAmb.
8oz Amb/Clear
Meoh- Bisulfate-
DI-
Thiosulfate-
250 mLAmb.
Col./Bacteria Other Plastic
SOC Kit
250 ml Plastic Flashpoint
Other Glass Plastic Ba
4oz Amb/Clear 2oz Amb/Clear
Encore Frozen:
Sulfuric- Perchlorate Ziplock Comments:
}J >.:...,.-p't \- \f"'€
CJ(\ GC. / (r;..J1. ¥--t 1'\tC\
I Have Not Confirmed Sample Container
Numbers With Lab Staff Before Relinquishing Over Samples _
· < t>o.c#21t<t1 vs 2011<<< ·
APPENDIX E
Sample & Material Location Sketches
042, 043
027, 028
048, 049
004, 005
021, 022
045, 046 017 023
010, 011
013 018, 019 024, 025, 007, 008
033, 034
06 020
014, 015 04
Basement Floor Hatch
054, 055
030, 031
02 05
Main Floor
Legend Asbestos Sample Locations
XXX > 1% Asbestos Sample Location
XXX < 1% Asbestos Sample Location
XXX No Asbestos Sample Location
XX Lead Based Paint Sample Location
XX Non-Lead Based Paint Sample Location
N
212 Douglas Avenue Randolph, Nebraska 68771
DWN BY
JVT
SCALE
NONE
Omaha, NE 68137 DATE
7/23/2021
JOB NUMBER
204BS04057
SHEET
1 of 2 Ph. (402) 697-9747
Hay Barn Storage
078, 079
080 081, 082
Car Port
072, 073
075, 076
069, 070
Multiple Sheds
051, 052
063, 064
066, 067
036, 037
038 059 060, 061
039, 040
041 057
Basement
Main House
Property View (Roof)
Legend
Ph. (402) 697-9747
Asbestos Sample Locations Residential Property 212 Douglas Avenue
XXX
XXX
XXX
> 1% Asbestos Sample Location < 1% Asbestos Sample Location No Asbestos Sample Location DWN BY
JVT SCALE
NONE
DATE
7/23/2021
JOB NUMBER
204BS04057
Basement Floor Hatch
Basement Main House
ACM Plaster Located Throughout the House:
Walls and Ceiling
Legend
Ph. (402) 697-9747
Asbestos Sample Locations Residential Property 212 Douglas Avenue Randolph, Nebraska 68771
9 x 9 Floor Tile (ACM) and Black Adhesive (Non-ACM)
Window Glazing (Door and Windows)
TSI - (Air Cell and Pipe Wrap)
DWN BY
JVT
SCALE
NONE
DATE
7/23/2021
JOB NUMBER
204BS04057
APPENDIX F
Photographs
Hazardous Materials Inspection
204BS04057, Randolph, NE 68771 Photos Taken July 7, 2021 ■ ATC Project No. 204BS0405