Am-0003_W9128F-19-R-0004.pdf

PDF 2 MB Posted

Attached to
SOF Human Performance Training Center Federal contract opportunity
Solicitation number
W9128F19R0004
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

Amendment 0003 Documentation

View the file

Other files for this federal contract opportunity

Other files attached to SOF Human Performance Training Center, newest first.
File Type Posted
Am-0005_W9128F-19-R-0004.pdf PDF
Am-0004_W9128F-19-R-0004.pdf PDF
Am-0002_W9128F-19-R-0004.pdf PDF
Am-0001_W9128F-19-R-0004.pdf PDF
CAD-BIM-Files_Instructions.txt TXT text file
FCBQ.zip ZIP file
SPECS_W9128F-19-R-0004.pdf PDF
SID_Color_Board_RTA_SOF_HPTF_FCN.pdf PDF
SOF_HPTF_FFE_RTA_for_Binder.pdf PDF
22x34_FCBQ_Advertisement.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended, by one of the following methods:

(a) By completing items 8 and 15, and returning or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

E. IMPORTANT: Contractor is not is required to sign this document and return copies to the issuing office.

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE

2. AMENDMENT/MODIFICATION NUMBER 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQUISITION NUMBER 5. PROJECT NUMBER (If applicable)

7. ADMINISTERED BY (If other than Item 6) CODE

STANDARD FORM 30 (REV. 11/2016)

Prescribed by GSA FAR (48 CFR) 53.243

FACILITY CODE

9A. AMENDMENT OF SOLICITATION NUMBER

9B. DATED (SEE ITEM 11)

10A. MODIFICATION OF CONTRACT/ORDER NUMBER

10B. DATED (SEE ITEM 13)

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers is extended. is not extended.

12. ACCOUNTING AND APPROPRIATION DATA (If required) copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NUMBER AS DESCRIBED IN ITEM 14.

CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT ORDER

NUMBER IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15C. DATE SIGNED

15A. NAME AND TITLE OF SIGNER (Type or print)

16C. DATE SIGNED

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

PAGE OF PAGES

6. ISSUED BY CODE

8. NAME AND ADDRESS OF CONTRACTOR (Number, street, county, State and ZIP Code) (X)

CODE

15B. CONTRACTOR/OFFEROR

(Signature of person authorized to sign)

16B. UNITED STATES OF AMERICA

(Signature of Contracting Officer)

Previous edition unusable

Amendment No. 0003 W9128F

SOF HUMAN PERFORMANCE TRAINING CENTER, PN 79447 (FY19), FORT CARSON, COLORADO

See attached documentation for content of the amendment revisions to solicitation

Date for receipt of proposals is 19 FEB 2019 at 1400 hours

Government Point of Contact: Bill Rawe, Contract Specialist (402) 996-3722

U.S.ARMY CORPS OF ENGINEERS, OMAHA

Rocky Mountain Area Office Attn: CONTRACTING DIVISION (CENWO-CT-M) 5475 Tech Center Drive, Suite 205 Colorado Springs, CO 80919

See Item 6

W9128F-19-R-0004

01/31/2019

01/09/2019

01/31/2019

Am #0003 - 1

Am #0003 - 2 (Continuation SF 30)

31 January 2019 Solicitation No. W9128F 19 R 0004

Date of Issue: 09 JAN 2019 Date of Receiving Proposals: 19 FEB 2019

SUBJECT: Amendment No. 0003 to Request for Proposal Solicitation Package for Design and Construction of SOF HUMAN PERFORMANCE TRAINING CENTER.

TO: Prospective Offerors and Others Concerned

1. The specifications and drawings for subject project are hereby modified as follows (revise all specification indices, attachment lists, and drawing indices accordingly).

a. Specifications. (Descriptive Changes.)

NONE

b. Specifications (New and/or Revised and Reissued). Delete and substitute or add specification pages or sections as noted below. The substituted pages or sections are revised and reissued with this amendment. For convenience, on the revised specification pages, changes have been identified with highlighting, all portions of the revised specification pages apply regardless of whether changes are shown with highlighting.

Pages or Sections Deleted Pages or Sections Substituted or Added 01 33 29 Attachment 1 01 33 29 Attachment 1 Appendix B – Room Data Sheets, Appendix B – Room Data Sheets, Page 5 Page 5

2. This amendment is a part of the proposing papers and its receipt shall be acknowledged. All other conditions and requirements of the request for proposal remain unchanged.

3. Electronic Proposals. Provide proposals via the instructions provided in Section 00 22 00 of the Request for Proposal.

4. Offers will be received until 2:00 p.m., local time at place of receiving proposals, 19 FEB 2019.

Attachments:

Site Visit Attendance Roster, For Information Only Specification Pages listed in 1.b., above

U.S. Army Corps of Engineers, Omaha District 1616 Capitol Avenue Omaha, Nebraska 68102-4901

31 JAN 2019

nep/2160

Am #0003 FOR INFORMATION ONLY

This page was intentionally left blank for duplex printing.

Silver

% Baseline

100%

100%

0%

0%

POC: Alec Walz, CENWO-EDD-G Phone: 402-995-2162 eMail: Alec.Walz@USACE.Army.Mil

SOF Human Performance Training Center - Ft Carson, CO FCBQ

Am #0003 01 33 29AT1 n/a

0.0% 0.0% #DIV/0!

IPC 2006

Energy & Sustainability Mandates Worksheet

Does not include mandates prior to 2005 or those that are generally met

100%

100% 100%

100%

100% 100% Fleet Vehicle Support

100%

100% 100%

100% 100% Building Management

100% 100%

Overall Rating: 100% 100%

Support for Local Communities

Products and Equipment

Renewable Energy Usage

High Performance Sustainable Buildings

Advanced Metering and Measurement

Energy Efficiency in New Construction and Major Renovations

Renewable Energy Generation

Building Energy Intensity (Gross)

01 33 29 AT1 - HPSB Checklist.xlsx, printed on 12/6/2018 at 2:56 PM

LEED v4 for BD+C: New Construction and Major Renovation Project Checklist

Project Name: HUMAN PERFORMANCE TRAINING CENTER - PN79447 (FY19) Project Address: FORT CARSON, CO

Y ? N

1 Credit 1

2 1 29 16

16 Credit 16 1 Credit 1

2 Credit 2 Historic District 1 Priority Designation 1 Brownfield Remediation 2

5 Credit 5 Surrounding Density 2-3 Diverse Uses 1-2

5 Credit 5 1 Credit 1

1 Credit 1 1 Credit Green Vehicles 1

6 1 4 10

Y Prereq Required 1 Credit 1

2 Credit 2 On-Site Restoration 1-2 Financial Support 1

1 Credit 1 2 1 Credit 3

Percentile of Rainfall Events 1-3 Natural Land Cover Conditions 2-3

2 1 Credit 2 2 Nonroof and Roof 1-2

Parking Under Cover 1 1 Credit 1

6 3 2 11

Y Prereq Required Y Prereq Required Y Prereq Building-Level Water Metering Required 2 Credit 2

2 No Irrigation Required 2 Reduced Irrigation 1-2

3 3 Credit 6 Reduce by 25% 1 Reduce by 30% 2

3 Reduce by 35% 3 Reduce by 40% 4 Reduce by 45% 5 Reduce by 50% 6

2 Credit 2 1 Credit Water Metering 1

Access to Quality Transit

Reduced Parking Footprint

Open Space

Site Assessment

Rainwater Management (Up to 3 points)

Light Pollution Reduction

Cooling Tower Water Use

Construction Activity Pollution Prevention

High Priority Site (Up to 2 points)

Surrounding Density and Diverse Uses (Up to 5 points)

Sustainable Sites

Heat Island Reduction (Up to 2 points)

Outdoor Water Use Reduction (Up to 2 points)

Indoor Water Use Reduction (Up to 6 points)

Outdoor Water Use Reduction Indoor Water Use Reduction

Water Efficiency

Location and Transportation

Sensitive Land Protection LEED for Neighborhood Development Location (Up to 16 Points)

Bicycle Facilities

Integrative Process

Site Development - Protect or Restore Habitat (Up to 2 points)

12 10 11 33

Y Prereq Required Y Prereq Required Y Prereq Required Y Prereq Required 2 4 Credit 6

Enhanced Systems Commissioning 3-4 2 Envelope Commissioning 2

8 10 0 Credit 18 8 Whole-Building Energy Simulation 1-18

Prescriptive Compliance: ASHRAE Advanced Energy Design Guide 1-6 1 Credit 1

2 Credit 2 3 Credit 3

1 Credit 1 1 No Refrigerants or Low-Impact Refrigerants 1

Calculation of Refrigerant Impact 1 2 Credit 2

8 0 5 13

Y Prereq Required Y Prereq Required

5 Credit 5 Historic Building Reuse 5 Renovation of Abandoned or Blighted Building 5 Building and Material Reuse 2-4 Whole-Building Life-Cycle Assessment 3

2 Credit 2 Environmental Product Declaration 1 Multi-Attribute Optimization 1

2 Credit 2 Raw Material Source and Extraction Reporting 1 Leadership Extraction Practices 1

2 Credit Building Product Disclosure and Optimization - Material Ingredients (Up to 2 points) 2 Material Ingredient Reporting 1 Material Ingredient Optimization 1

2 Credit 2 Diversion 1

2 Divert 75% and Four Material Streams 2 Reduction of Total Waste Material 2

8 5 2 Indoor Environmental Quality 16

Y Prereq Required Y Prereq Required 1 1 Credit 2 3 Credit 3 1 Credit Construction Indoor Air Quality Management Plan 1 1 1 Credit 2

1 Flush-Out 1

Air Testing 2 1 Credit 1 1 1 Credit 2

1 Lighting Control 1 Lighting Quality 1

2 Credit 3 Simulation: Spatial Daylight Autonomy 1-3

2 Simulation: Illuminance Calculations 1-2 Measurement 1-3

1 Credit 1 1 Credit 1Acoustic Performance

Quality Views

Enhanced Indoor Air Quality Strategies Low-Emitting Materials

Indoor Air Quality Assessment (Up to 2 points)

Thermal Comfort Interior Lighting

Daylight (Up to 3 points)

Environmental Tobacco Smoke Control

Energy and Atmosphere

Minimum Energy Performance

Fundamental Refrigerant Management

Building Life-Cycle Impact Reduction (Up to 5 points)

Green Power and Carbon Offsets

Enhanced Commissioning (Up to 6 points)

Building-Level Energy Metering

Fundamental Commissioning and Verification

Demand Response

Construction and Demolition Waste Management (Up to 2 points)

Minimum Indoor Air Quality Performance

Building Product Disclosure and Optimization - Environmental Product Declarations (Up to 2 points)

Renewable Energy Production Enhanced Refrigerant Management (Up to 1 point)

Building Product Disclosure and Optimization - Sourcing of Raw Materials (Up to 2 points)

Construction and Demolition Waste Management Planning

Materials and Resources

Storage and Collection of Recyclables

Optimize Energy Performance (Up to 18 points)

Advanced Energy Metering

4 2 0 Innovation 6

3 2 Credit 5 Innovation 1 Pilot 1 Additional Strategies, Innovation 1-3 Additional Strategies, Pilot 1-3 Additional Strategies, Exemplary Performance 1-2

1 Credit 1

3 1 0 Regional Priority 4

1 Credit Regional Priority: Specific Credit Outdoor Water Use Reduction 1 1 Credit Regional Priority: Specific Credit Indoor Water Use Reduction 1

1 Credit Regional Priority: Specific Credit Optimize Energy Performance 1 1 Credit Regional Priority: Specific Credit Rainwater Management 1

50 23 53 TOTALS Possible Points: 110 Certified: 40 to 49 points, Silver: 50 to 59 points, Gold: 60 to 79 points, Platinum: 80 to 110

LEED Accredited Professional

Innovation (Up to 5 points)

This page was intentionally left blank for duplex printing.

APPENDIX B– ROOM DATA SHEETS HUMAN PERFORMANCE TRAINING FACILITY

Am #0003 PAGE 5 OF 33

MULTI-PURPOSE ROOM – A

Summary: Multipurpose Room – A (Teaching Kitchen)

A. Quantity: 1

B. Function: Kitchenette shall accommodate 1 trainer and at least 12 students. The Multipurpose Room shall allow for flexible table arrangement and shall accommodate a refrigerator, double basin sink, microwave, dishwasher, and two ovens with range tops with exhaust hoods at the front of the kitchenette. The room shall be equipped with dimmable lighting, an audio/visual display system, and dry erase magnetic wallcovering. Windows shall have window treatment.

C. Adjacency: As shown

D. Minimum Area: As shown

E. Number of Occupants: 0 FTE (12 students and 1 instructor/dietician)

F. Architectural Design:

● Special Construction ○ Dimmable lighting

○ Dual Roller Window Shade

○ STC 50 wall construction

○ Vertically Retractable Wall

○ Classroom tables shall have power & data

○ Dry erase magnetic wallcovering

○ Utility connections for ranges/ovens (gas), refrigerators, microwave, dishwasher, sink

○ Electrical outlets for each individual counter section

● Communications ○ 2 NIPR Data drop (1 at TV, 1 in floor at demo table)

○ 1 telephone drop

○ 2 NIPR Data drops and one power outlet in floor for each classroom table

○ HDMI source ports and connections to projector in Multipurpose Room

– B and monitor in Multipurpose - A, 1 source port per Multipurpose room. coordinate with users for location of source ports to reduce long cable runs and tripping hazards. Projector and monitor shall be capable of displaying the same media simultaneously from one source port, or each displaying different media from different source ports.

● Built-In Equipment ○ One double basin kitchen sink W/ Garbage disposal

○ Two residential exhaust hoods, finish to match dishwasher and FF&E appliances

○ One Dishwasher –stainless steel or smudgeproof stainless steel finish, 24" wide, ADA Accessible, stainless steel interior, ENERGY STAR or performance equivalent

○ Casework and wall cabinets with counter space for sink, dishwasher refrigerator, and a microwave.

○ One flat panel TV wall mount

G. Furniture, Fixtures, and Equipment:

● CFCI (Furniture Bid Option) ○ See furniture package for types, requirements and quantity, and furniture plans for locations

Standard_Form_30
Am-0003_W9128F-19-R-0004_Narrative
Attachments
Site Visit Attendance Roster HPTC - FIO
01 33 29AT1 - HIGH PERFORMANCE AND SUSTAINABLE BUILDING (HPSB) CHECKLIST
Appendix B - Room Data Sheets - page 5

File details come from the government source that posted it.