22x34_FCBQ_Advertisement.pdf

PDF 9 MB Posted

Attached to
SOF Human Performance Training Center Federal contract opportunity
Solicitation number
W9128F19R0004
Issued by
Department of the Army Corps of Engineers Engineering District Omaha

About this file

Drawings

View the file

Other files for this federal contract opportunity

Other files attached to SOF Human Performance Training Center, newest first.
File Type Posted
Am-0005_W9128F-19-R-0004.pdf PDF
Am-0004_W9128F-19-R-0004.pdf PDF
Am-0003_W9128F-19-R-0004.pdf PDF
Am-0002_W9128F-19-R-0004.pdf PDF
Am-0001_W9128F-19-R-0004.pdf PDF
CAD-BIM-Files_Instructions.txt TXT text file
FCBQ.zip ZIP file
SPECS_W9128F-19-R-0004.pdf PDF
SID_Color_Board_RTA_SOF_HPTF_FCN.pdf PDF
SOF_HPTF_FFE_RTA_for_Binder.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SLAB

CANOPY

PUMP

MAIN GATE (GATE 1)

(GATE 4)

"B" STREET GATE

SECURITY CHECKPOINT

GATE 3 - CONTRACTOR'S

GATE 20

GATE 19

GATE 6

LAYDOWN AREA

AND CONTRACTOR

PROJECT SITE

ACCESS ROUTE

CONTRACTOR'S

ACCESS ROUTE

CONTRACTOR'S

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:16:47 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\LOCATION PLAN

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

O M

A H

A

N E

F

IL

E N

A M

E

A N

S I

D A

N S I

D

O M

A H

A

N E

F

IL

E N

A M

E

G-006

C

A P

IT

O L A

V E

F

IL

E N

U M

B E

R

C

A P

IT

O L A

V E

F

IL

E N

U M

B E

R

G-006

F C

B Q

G -0

.d g n

F C

B Q

G -0

.d g n

O M

A H

A D

IS

T R

IC

T O

M A

H A D

IS

T R

IC

T

F O

R T C

A R

S O

N

C O

L O

R A

D O

F O

R T C

A R

S O

N

C O

L O

R A

D O

/2

/2

/2

/2

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:16:47 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\LOCATION PLAN

A N

S I

D

ACADEMY BLVD

IN

T E R S T A T E

C H

IL

E S A

V E

P R

U S S

M A N B

LV

D

B U

T T S R

O A

D

TITUS BLVD

S P E C

K E R A

V E

W E T Z E L A

V E

WILDERNESS ROAD

0 4000'2000'

SCALE: 1" = 2000'

N

G-006

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O

T

L

C A

T

IO

N P

L A

N F

IL

E N

U M

B E

R

W .C

D A

V E

N P

O R

T

F

IL

E N

A M

E

L O

C A

T

IO

N P

L A

N L

O C

A T

IO

N P

L A

N

2. SEE SPECIFICATION 01 30 00.24 FOR FURTHER DETAILS ON ACCESS REQUIREMENTS/GUIDELINES..

1. COMMERCIAL VEHICLES ARE REQUIRED TO ENTER AND EXIT THROUGH GATE 3.

NOTES:

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R S

O F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

P N

F

Y

P N

F

Y

W F -1

-R -0

W F -1

-R -0

W F -1

-R -0

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

E L E

V A

T

IO

N F

E E

T N

A V

D

E L E

V A

T

IO

N F

E E

T N

A V

D

M LL PIN

16.523

50 13.7

13.7

74 12.1

13.3

11.7

60+

60+

C.I. 8/15

CL

CH 2851

29CH50

M LL PIN

CH

13.523

51 13.0

13.2

78 13.6

14.5

C.I. 8/14

SC

CH

CH

16.2

13.860+

13.560+

SC

CH

CH

ELEV. 5870.9 FEET

AUG 15, 2018

FC18-73

ELEV. 5863.4 FEET

AUG 14, 2018

FC18-74

Groundwater table not encountered.

Split-spoon refusal encountered at 19.2 feet.

Groundwater table not encountered.

Split-spoon refusal encountered at 29.4 feet.

medium sand, 10% coarse sand,1% fine gravel, 8% coarse gravel, damp

SANDY FAT CLAY, olive brown, very stiff, 50% fines, 11% fine sand, 20%

18% medium sand, 10% coarse sand, damp

SANDY FAT CLAY, dark yellowish brown, hard, 60% fines, 12% fine sand, 17% medium sand, 7% coarse sand, damp

FAT CLAY WITH SAND, very dark gray, hard, 70% fines, 6% fine sand, 25% medium sand, 17% coarse sand, 1% fine gravel, damp

CLAYEY SAND, very dark gray, very dense, 47% fines, 10% fine sand, GP

POORLY GRADED GRAVEL (FILL)

sand, some coarse sand, some coarse gravel, trace fine gravel, damp

SANDY FAT CLAY, greenish gray, very stiff, fines, medium sand, some fine sand, trace fine gravel, damp, pH=7.9, resistivity=700 ohm-cm, SO =695mg/kg

SANDY LEAN CLAY, olive gray, hard, fines, coarse sand, medium sand, some fine sand, some coarse sand, damp

SANDY FAT CLAY, light gray, hard, fines, medium sand, some fine sand, some coarse sand, damp, cobble/boulder at 8.7 to 9.2 feet

SANDY FAT CLAY, light gray, hard, fines, medium sand, some fine some coarse sand, some fine sand, damp

FAT CLAY WITH SAND, olive gray, hard, fines, medium sand, coarse sand, some fine sand, trace fine gravel, damp

CLAYEY SAND, light gray, very dense, fines, medium sand, BORING LEGEND

FC18-73 DRILL HOLE NUMBER

AUG 15, 2018 DATE BORING COMPLETED

M

LL

PI

N

NATURAL MOISTURE CONTENT (%)

LIQUID LIMIT

PLASTICITY INDEX

STANDARD PENETRATION BLOW COUNT.

OUTSIDE DIAMETER SAMPLER 1 FOOT.

NUMBER OF BLOWS FOR A 140-POUND WEIGHT

DROPPING 30 INCHES TO DRIVE A 2-INCH

BORING NOTES

BORING LOGS FOR LABORATORY DETERMINATION OF MOISTURE CONTENTS FOR THE SOIL.

BY THE INSPECTOR IN THE FIELD AT THE TIME OF DRILLING. SEE "M" ON THE CONDENSED

LABORATORY DATA. THE TERMS "DRY, MOIST, WET, ETC." ARE FIELD DESCRIPTIONS MADE

1. THE DESCRIPTIONS AT THE RIGHT OF THE LOGS ARE THE RESULTS OF FIELD AND

ELEV.

C.I. 8/15 CAVE IN DEPTH AND DATE MEASURED

SULFATE ION CONTENT IN SOIL (mg/kg)

SURVEYED TOP OF BORING ELEVATION (NAVD88 DATUM)

SO

LOCATIONS AND ARE CONSIDERED REPRESENTATIVE OF THE SOILS AT THAT LOCATION.

2. THE LOGS FURNISHED REPRESENT THE TYPES OF SOIL ENCOUNTERED AT THEIR RESPECTIVE

SHOULD IDENTIFY GROUNDWATER CONDITIONS PRIOR TO THE TIME OF CONSTRUCTION

OR FROM YEAR TO YEAR DEPENDING LARGELY ON CLIMACTIC CONDITIONS. THE CONTRACTOR

GROUNDWATER TABLE CAN FLUCTUATE APPRECIABLY AT DIFFERENT SEASONS OF THE YEAR

3. GROUNDWATER WAS NOT ENCOUNTERED IN ANY OF THESE BORINGS. HOWEVER, THE

TWO CONSECUTIVE INTERVALS, THE SPT IS DISCONTINUED.

INTERVAL OF THE STANDARD PENETRATION TEST (SPT). ONCE REFUSAL IS ENCOUNTERED IN

4. REFUSAL (N=60+) IS DEFINED AS A CUMULATIVE BLOW COUNT EXCEEDING 60 IN ANY SIX-INCH

CAN BE ANTICIPATED AT ANY DEPTH AT THE SITE.

EXCEEDING 60 WERE ENCOUNTERED. COBBLES AND BOULDERS WERE ENCOUNTERED AND

5. NOTE THAT BORING LOGS INDICATE THAT HARD AND VERY DENSE SOILS AND SPT VALUES

6. FOR SOIL BORING LOCATIONS, SEE SHEETS VF100 AND VF101.

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:10:02 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Soil Boring Logs FC18-73 to FC18-74

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

F

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

B -3

.d g n

F C

B Q

B -3

.d g n

B-301

A N

S I

D

C F

R

IT

Z S

C H

J P

O R

T E

R

J P

O R

T E

R

S O

IL

B

O R

IN

G L

O G

S

F C

-7

T

O F

C -7

B F

L E

R E

/2

/2

W F -1

-R -0

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

M LL PIN

CH

14.815

27 8.6

14.3

67 12.9

16.0

CL

CH

12.8

71 CH

C.I. 8/15 11.960+

60+

CH

49 28

54 34

M LL PIN

CH

22.312

15 18.5

17.0

71 17.8

13.8

SC

CH

SC

C.I. 8/14

14.4

60+

60+

CH

E L E

V A

T

IO

N F

E E

T N

A V

D

E L E

V A

T

IO

N F

E E

T N

A V

D

ELEV. 5882.2 FEET

AUG 15, 2018

FC18-75

ELEV. 5876.5 FEET

AUG 14, 2018

FC18-76

Groundwater table not encountered.

Split-spoon refusal encountered at 24.4 feet.

Groundwater table not encountered.

Split-spoon refusal encountered at 19.8 feet.

sand, 15% medium sand, 17% coarse sand, 3% fine gravel, damp

SANDY LEAN CLAY, dark gray, very stiff, 57% fines, 8% fine

5% coarse sand, 11% fine gravel, damp hard, 60% fines, 13% fine sand, 11% medium sand, SANDY FAT CLAY (WEATHERED SHALE), olive gray, 21% medium sand, 6% coarse sand, 9% fine gravel, damp

SANDY FAT CLAY, dark grayish brown, stiff, 52% fines, 12% fine sand, fine sand, 18% medium sand, 10% coarse sand, damp

SANDY FAT CLAY, dark to light gray, hard, 55% fines, 17%

POORLY GRADED GRAVEL (FILL)

GP

fine sand, some coarse sand, some coarse gravel, trace fine gravel, damp

SANDY FAT CLAY, greenish gray, stiff to very stiff, fines, medium sand, some sand, some coarse sand, damp

SANDY FAT CLAY, olive gray, hard, fines, medium sand, some fine some coarse sand, some fine sand, damp

FAT CLAY WITH SAND, olive gray, hard, fines, medium sand, 4gravel, some coarse sand, damp, pH=7.8, resistivity=1510 ohm-cm, SO =161mg/kg

SANDY FAT CLAY, olive gray, stiff, fines, medium sand, some fine sand, some fine coarse sand, some fine sand, trace fine gravel, damp

CLAYEY SAND, olive gray, dense, fines, medium sand, coarse sand, some fine sand, trace fine gravel, damp

CLAYEY SAND, olive gray, very dense, fines, medium sand, E L E

V A

T

IO

N F

E E

T N

A V

D

E L E

V A

T

IO

N F

E E

T N

A V

D

M LL PIN

CH

19.013

65 14.1

15.0

75 12.2

11.6

CL

CH

10.660+

CH

C.I. 8/15

SC

CL

60+

ELEV. 5875.9 FEET

AUG 15, 2018

FC18-77

Groundwater table not encountered.

Split-spoon refusal encountered at 19.4 feet.

GC

CLAYEY GRAVEL WITH SAND (FILL)

medium sand, some fine sand, trace fine gravel, damp

SANDY LEAN CLAY, greenish gray, hard, fines, coarse sand, medium sand, some fine sand, trace fine gravel, damp

SANDY LEAN CLAY, dark gray, hard, fines, coarse sand, some coarse sand, some fine sand, damp

FAT CLAY WITH SAND, greenish gray, hard, fines, medium sand, some fine sand, some fine gravel, some coarse sand, damp

SANDY FAT CLAY, low plasticity, olive gray, stiff, fines, medium sand, fine sand, some coarse sand, damp

SANDY FAT CLAY, dark gray, hard, fines, medium sand, coarse sand, some fine sand, trace fine gravel, damp

CLAYEY SAND, dark gray, very dense, fines, medium sand, NOTES

2. FOR SOIL BORING LOCATIONS, SEE SHEETS VF100 AND VF101.

1. FOR SOIL BORING NOTES AND LEGEND, SEE SHEET B-301.

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:10:32 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Soil Boring Logs FC18-75 to FC18-77

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

B -3

.d g n

F C

B Q

B -3

.d g n

B-302

A N

S I

D

C F

R

IT

Z S

C H

J P

O R

T E

R

J P

O R

T E

R

S O

IL

B

O R

IN

G L

O G

S

F C

-7

T

O F

C -7

B F

L E

R E

/2

/2

W F -1

-R -0

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T

5880 5880

THE DIRTY NAME

OBSTACLE #1

LOW CRAWL

OBSTACLE #2

ISLAND HOPPER

OBSTACLE #3

PIT JUMPER

OBSTACLE #4

PIPE CROSSING

OBSTACLE #5

EASY BALANCER

OBSTACLE #6

6 VAULTS

OBSTACLE #7

THE TUNNEL

OBSTACLE #8

ONE ROPE BRIDGE

OBSTACLE #9

BALANCING LOGS

OBSTACLE #10

HORIZONTAL LADDER

OBSTACLE #11

WALL CLIMB

OBSTACLE #12

SWING, STOP & JUMP

OBSTACLE #13

CARGO NET CLIMB

ROPE BRIDGE &

ROPE CLIMB,

OBSTACLE #14

WORKOUT AREA

THOR 3

FC18-73

BORE HOLE

FC18-74

BORE HOLE

FC18-77

BORE HOLE

FC18-75

BORE HOLE

FC18-76

BORE HOLE

WORKOUT AREA

INVERT=5851.77

DIAMETER=30"

MATERIAL=RCP

RIM ELEVATION=5857.97

INVERT=5858.58

DIAMETER=30"

MATERIAL=RCP

INVERT=5885.79

DIAMETER=12"

MATERIAL=PVC

INVERT=5884.92

DIAMETER=12"

MATERIAL=PVC

INVERT=5901.53

DIAMETER=12"

MATERIAL=PVC

INVERT=5900.07

DIAMETER=12"

MATERIAL=PVC

INVERT=5886.33

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5893.55

INVERT=5870.20

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.15

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.30

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5844.17

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5852.45

INVERT=5844.35

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5852.45

INVERT=5842.97

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5852.45

INVERT=5856.33

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5866.51

INVERT=5835.96

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5844.91

INVERT=5838.57

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5844.91

INVERT=5835.79

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5844.91

INVERT=5830.01

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5845.91

INVERT=5850.05

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.55

INVERT=5850.72

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.40

INVERT=5850.81

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.40 INVERT=5851.55

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5854.58

INVERT=5851.66

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5854.58

INVERT=5851.73

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5851.69

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5853.46

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5858.11

INVERT=5855.40

DIAMETER=6"

MATERIAL=HDPE

INVERT=5853.26

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5855.11

INVERT=5854.64

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5858.24

INVERT=5850.56

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5845.88

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5820.28

INVERT=5866.66

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.34

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.26

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.35

DIAMETER=24"

MATERIAL=CMP

INVERT=5863.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5863.61

DIAMETER=18"

MATERIAL=CMP

INVERT=5860.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5858.62

DIAMETER=18"

MATERIAL=CMP

THE DIRTY NAME

OBSTACLE #1

LOW CRAWL

OBSTACLE #2

ISLAND HOPPER

OBSTACLE #3

PIT JUMPER

OBSTACLE #4

PIPE CROSSING

OBSTACLE #5

EASY BALANCER

OBSTACLE #6

6 VAULTS

OBSTACLE #7

THE TUNNEL

OBSTACLE #8

ONE ROPE BRIDGE

OBSTACLE #9

BALANCING LOGS

OBSTACLE #10

HORIZONTAL LADDER

OBSTACLE #11

WALL CLIMB

OBSTACLE #12

SWING, STOP & JUMP

OBSTACLE #13

CARGO NET CLIMB

ROPE BRIDGE &

ROPE CLIMB,

OBSTACLE #14

WORKOUT AREA

THOR 3

FC18-73

BORE HOLE

FC18-74

BORE HOLE

FC18-77

BORE HOLE

FC18-75

BORE HOLE

FC18-76

BORE HOLE

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

W O

R K

O U

T A

R

B U

IL

D

IN

G

A R

E A

W O

R K

O U

T

B U

IL

D

IN

G

BUILDING

B A

D T

O E

L Z R

O A

D

CO

CO

TS

S

CB

C

S

GG

CO

C

CB

CB

R

IM

E

L E

V A

T

IO

N

.5

M A

T E

R

IA

L R

C P

D

IA

M E

T E

R iN V

E R

T

.0

G

W

CB

G

CB

W

CB

W

CO

CB

CB

M

G

G

W W

G

E

S

TS

CO

W

T

COCO

T

CO

WT

CC

CPE

E

CP

S

W

CO

CP

CO

CP

W O

R K

O U

T A

R

IL

D

IN

G

A R

E A

W O

R K

O U

T

B U

IL

D

IN

G

BUILDING

B A

D T

O E

L Z R

O A

D

DISC IN CONCRETE5891.1503207357.184 1311677.109FOUNTAIN

DESCRIPTIONELEVATIONEASTINGNORTHINGNAME

CONTROL DATA

UTILITIES WERE LOCATED BY CONTRACTOR7)

ALL UTILITIES WERE LOCATED BY SURFACE INDICATION ONLY.6)

COMBINED GRID FACTOR IS: 0.999680162.5)

CONTOUR INTERVAL IS 1 US SURVEY FOOT.4)

FIELD SURVEY DATE:JUNE 2018.

TOPOGRAPHY IS DERIVED FROM GPS/RTK SURVEY METHODS.3)

VERTICAL DATUM OF 1988 (NAVD 88). THEY ARE BASED ON CONTROL POINT FOUNTAIN.

ELEVATIONS ARE REFLECTED IN US SURVEY FEET AND REFER TO THE NORTH AMERICAN2)

COLORADO CENTRAL(FIPS 0502). THEY ARE BASED ON CONTROL POINT FOUNTAIN

AMERICAN DATUM of 1983 (NAD 83) STATE PLANE COORDINATE SYSTEM FOR:

GRID COORDINATES ARE REFLECTED IN US SURVEY FEET AND REFER TO THE NORTH1)

SURVEY NOTES

SOIL BORING5875.853 3202629.9111323293.779FC18-77

SOIL BORING5876.491 3202706.8771323394.544FC18-76

SOIL BORING5882.185 3202545.1831323362.172FC18-75

SOIL BORING5863.407 3202788.950 1323234.965FC18-74

SOIL BORING5870.935 3202534.9821323207.119FC18-73

DESCRIPTIONELEVATION EASTINGNORTHINGNAME

BORE HOLES

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:17:25 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Overall Existing Conditions Plan

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

V F .d g n

F C

B Q

V F .d g n

.C

D A

V E

N P

O R

T

O V

E R

A L L E

X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF100

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T

O V

E R

A L L E

X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF100

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

N

NOT TO SCALE

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

R K

O U

T A

R

IL

D

IN

G

B U

IL

D

IN

G

FC18-73

BORE HOLE

FC18-74

BORE HOLEFC18-77

BORE HOLE

FC18-75

BORE HOLE

FC18-76

BORE HOLE

THE DIRTY NAME

OBSTACLE #1

WORKOUT AREA

6 VAULTS

OBSTACLE #7

THE TUNNEL

OBSTACLE #8

ONE ROPE BRIDGE

OBSTACLE #9

EASY BALANCER

OBSTACLE #6

PIPE CROSSING

OBSTACLE #5

CARGO NET CLIMB

ROPE BRIDGE &

ROPE CLIMB,

OBSTACLE #14

SWING, STOP & JUMP

OBSTACLE #13

BALANCING LOGS

OBSTACLE #10

HORIZONTAL LADDER

OBSTACLE #11

WALL CLIMB

OBSTACLE #12

THOR 3

PIT JUMPER

OBSTACLE #4

LOW CRAWL

OBSTACLE #2

ISLAND HOPPER

OBSTACLE #3

IL

D

IN

G

B U

IL

D

IN

G

WORKOUT AREA

W

INVERT=5858.58

DIAMETER=30"

MATERIAL=RCP

INVERT=5870.20

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.15

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.30

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5851.73

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5851.69

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5853.46

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5858.11

INVERT=5855.40

DIAMETER=6"

MATERIAL=HDPE

INVERT=5853.26

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5855.11

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5860.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5858.62

DIAMETER=18"

MATERIAL=CMP

INVERT=5863.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5854.64

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5858.24

INVERT=5863.61

DIAMETER=18"

MATERIAL=CMP

W

W

W

5880 5880

W

WOOD

CB

CBCB

CB

CBCB

CB

G

G

SS

T

SS

CO

CP

CO

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:17:54 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Existing Conditons Plan - Area 101

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

V F .d g n

F C

B Q

V F .d g n

W .C

D A

V E

N P

O R

T A

R E

A

E X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF101

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T A

R E

A

E X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF101

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

V0398

V0383

V0568

V0267

V0266

V0566

V0397

V0567

V0707

V0708

V0709

V0638

BUILDING

B A

D T

O E

L Z R

O A

D

W

INVERT=5851.77

DIAMETER=30"

MATERIAL=RCP

RIM ELEVATION=5857.97

INVERT=5850.56

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5845.88

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5820.28

INVERT=5866.66

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.34

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.26

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.35

DIAMETER=24"

MATERIAL=CMP

NO PRKNG FIRE LANE

MRS3113

544 5882.461

CC

CPE

E

CP

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:18:21 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Existing Conditions Plan - Area 102

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

V F .d g n

F C

B Q

V F .d g n

W .C

D A

V E

N P

O R

T A

R E

A

E X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF102

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T A

R E

A

E X

IS

T

IN

G C

O N

D

IT

IO

N S P

L A

N

VF102

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

R K

O U

T A

R

IL

D

IN

G

B U

IL

D

IN

G

FC18-73

BORE HOLE

FC18-74

BORE HOLEFC18-77

BORE HOLE

FC18-75

BORE HOLE

FC18-76

BORE HOLE

THE DIRTY NAME

OBSTACLE #1

WORKOUT AREA

6 VAULTS

OBSTACLE #7

THE TUNNEL

OBSTACLE #8

ONE ROPE BRIDGE

OBSTACLE #9

EASY BALANCER

OBSTACLE #6

PIPE CROSSING

OBSTACLE #5

CARGO NET CLIMB

ROPE BRIDGE &

ROPE CLIMB,

OBSTACLE #14

SWING, STOP & JUMP

OBSTACLE #13

BALANCING LOGS

OBSTACLE #10

HORIZONTAL LADDER

OBSTACLE #11

WALL CLIMB

OBSTACLE #12

THOR 3

PIT JUMPER

OBSTACLE #4

LOW CRAWL

OBSTACLE #2

ISLAND HOPPER

OBSTACLE #3

WORKOUT AREA

W

INVERT=5858.58

DIAMETER=30"

MATERIAL=RCP

INVERT=5870.20

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.15

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.30

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5851.73

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5851.69

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5853.46

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5858.11

INVERT=5855.40

DIAMETER=6"

MATERIAL=HDPE

INVERT=5853.26

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5855.11

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5860.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5858.62

DIAMETER=18"

MATERIAL=CMP

INVERT=5863.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5854.64

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5858.24

INVERT=5863.61

DIAMETER=18"

MATERIAL=CMP

W W

W

W

WOOD

CB

CBCB

CB

CBCB

CB

G

G

S

T

S

CO

CP

CO

DISTANCES AND GRADES.

MAINTAIN EXISTING OBSTACLE

COURSE TO AVOID NEW SITE PLAN.

RELOCATE EXISTING OBSTACLE

OF OBSTACLES (TYP.).

TO MATCH NEW LOCATIONS

RELOCATE EXISTING SIGNS

DEMO. EXISTING SIDEWALK

DEMO. EXISTING SIDEWALK

CHECK DAMS (TYP.)

DEMO. EXISTING ROCK

CULVERT AND FES

DEMO. EXISTING

CONCRETE CHANNEL

DEMO. EXISTING

WALKWAY

AGGREGATE

DEMO. EXISTING

WHERE APPLICABLE (TYP.)

AGGREGATE AND REUSE

EROSION CONROL

REMOVE EXISTING

WHERE APPLICABLE (TYP.)

AGGREGATE AND REUSE

EROSION CONROL

REMOVE EXISTING

AREA, COORDINATE WITH BASE

RELOCATE EXISTING WORKOUT

F.O. DIRECT BURY)

ABANDON IN PLACE (24 STND.

F.O. DIRECT BURY)

ABANDON IN PLACE (24 STND.

WATER LINE

DEMO. EXISTING

MANAGE STORM RUNOFF.

INLET TO ADEQUATELY

AND INSTALL MANHOLE/AREA

DEMO. EXISTING CATCH BASIN

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:11:08 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\DEMOLITION PLAN - AREA 101

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

C D

.d g n

F C

B Q

C D

.d g n

W .C

D A

V E

N P

O R

T A

R E

A

CD101

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T A

R E

A

CD101

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

D E

M O

L

IT

IO

N P

L A

N D

E M

O L

IT

IO

N P

L A

N

BY THE NEW SITE PLAN.

2. DESIGN SHALL MITIGATE EXISTING STORMWATER RUNOFF THAT WILL BE DISTURBED

FOR EROSION CONTROL.

1. EROSION CONTROL AGGREGATE SHALL BE SALVAGED AND REUSED IN THE DESIGN

NOTES:

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

IL

D

IN

G

B U

IL

D

IN

G

8'

10'

.1

12'

STOOP (TYP.)

STOOP (TYP.)

STOOP (TYP.)

STOOP (TYP.)

TIE INTO EXISTING WALKWAY

5'

5' 8'

10'

SIDEWALK

CONCRETE

VEHICLE ACCESS

WALKWAY / EMERGENCY

CONCRETE PEDESTRIAN

VEHICLE ACCESS

WALKWAY / EMERGENCY

CONCRETE PEDESTRIAN

STANDOFF

60-FT AT/FP

STANDOFF

60-FT AT/FP

EQUIPMENT PAD

ELECTRICAL AND MECHANICAL

PROPOSED LOCATION OF

OF LID FEATURE

PROPOSED LOCATION

30'

42'

6' 6'

'1

SIDEWALK

EXISTING

TIE INTO

CONCRETE SIDEWALK

SIDEWALK

CONCRETE

4,000 SF (SEE 01 81 00 FOR DETAILS)

BID OPTION - CONSTRUCT ADDITIONAL

8,000 SF (SEE 01 81 00 FOR DETAILS)

BID OPTION - CONSTRUCT ADDITIONAL

TURFED SPRINT AREA

BID OPTION - EXTERIOR

5 YARD STRIPING INTERVALS

(TYP.)

BICYCLE RACK

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

R

5'R

R

N 1,323,221.15

E 3,202,723.00

N 1,323,206.66

E 3,202,796.47

N 1,323,235.51

E 3,202,812.47

N 1,323,270.96

E 3,202,721.85

SOF HUMAN PERFORMANCE TRAINING CENTER

R

R

.0

R

28.06'

R

N 1,323,415.89

E 3,202,790.01

N 1,323,403.45

E 3,202,786.35

N 1,323,204.19

E 3,202,559.65

N 1,323,364.23

E 3,202,543.04

N 1,323,381.18

E 3,202,706.39

RELOCATED OBSTACLE COURSE

PROPOSED FOOTPRINT FOR

N 1,323,521.63

E 3,202,568.98N 1,323,518.54

E 3,202,539.14

N 1,323,444.09

E 3,202,509.74

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:11:39 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\Site Plan - Area 101

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

C S .d g n

F C

B Q

C S .d g n

W .C

D A

V E

N P

O R

T A

R E

A

CS101

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T A

R E

A

CS101

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

S

IT

E P

L A

N S

IT

E P

L A

N

NORTH AND MAINTAIN EXISTING GRADES AND DISTANCES.

3. EXISTING OBSTACLE COURSE TO THE NORTH OF THE PROJECT IS TO BE RELOCATED

CLEARANCES IN THE EVENT THAT THE BID OPTIONS ARE AWARDED.

2. EXISTING TRAILS AND PROPOSED SIDEWALKS SHALL BE READJUSTED TO CURRENT

REQUIRED BY NFPA 1.

/ EMERGENCY VEHICLE ACCES TO COMPLY WITH THE 20-FT UNOBSTRUCTED PATH

1. MAINTAIN A 4-FT CLEAR ZONE ON BOTH SIDES OF CONCRETE PEDESTRIAN WALKWAY

NOTES:

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

SW0019

SW0329

V0638

120_240V 1-150-3

TR00980

480Y_277V 1-500-3

TR00367

208Y_120V 1-112.5-1

TR00851

120_240V 1-300-3

TR00356

480Y_277V 1-500-3

TR00365

480Y_277V 1-500-3

TR00366

480Y_277V 1-225-3

TR00370

480Y_277V 1-225-3

TR00368

480Y_277V 1-500-3

TR00369

480Y_277V 1-225-3

TR00362

208Y_120V 1-150-3

TR01326

480Y_277V 1-225-3

TR01333

1" (P

E)

" (P

E

2" (CI

2" (C I)

2" (PE)

2" (C I)

(P

E

" (C

I)

(P

E

4" (C I)

2" (

CI)

" (C

I)

4" (C I)

(C I)

2" (CI

" (C

I)

.5 " (P

E

.5 " (P

E

" (P

E

" (C

I)

(C I)

4" C I)

(C I)

4" (PE)

(C I)

00315

00316

00310

00314

02029

02106

02079

02073

02019

02043

01418

01428

01430

GR308A

00092

01450

01487

01444

01396

01488

01472

01457

01452

01491

01445

01489

01378

01377

01496

01479

01459

01494

01415

01418

01421

01880

01879

01878

01877

01469

01417

01495

01442

01458

01493

01416

01426

02470

02447

02417

02421

02401

02400

02528

02515

02492

02493

02452

02443

02482

02480

02530

02534

02442

02439

02521

02495

02513

02505

02539

02394

02441

02423

02414

02525

02462

02467

02448

02427

02464

03021

03171

02469

02451

02399

02471

02460

02404

03020

02487

02536

03170

U-2 0 02 D

U-20 03 D

" (R

C

12" (RC)

12" (R

C)

" (R

C

(P

V C

(P

V C

" (P

O L

Y E

T H

Y L E

N E

12"

(PVC)

1" (POLYETHYLENE)

(P

O L

Y E

T H

Y L E

N E

1" (P

O

LYETHYLE

NE)

" (R

C

24" (R C)

" (R

C

(R

C

(R

C

" (R

C

12" (P V C

" (R

C

RC)

00301

00300

00304

00311

00319

00299

00298

00297

00303

00320

00296

6" P V C

" (P

V C

8" P V C

6" (P V C

3" P V C

6" (PVC)

4" (PVC)

" (P

V C

8" P V C

8" P V C

8" P V C

8" (P V C

8" (P V C

6" P V C

6" P V C

(P

V C

12" (PVC)

(P

V C

8" (PVC)

8" (PVC)

" (P

V C

12" (PVC)

8" (PVC)

(P

V C

(P

V C

6" P V C

8" (PVC)

8" (PVC)

" (P

V C

" (P

V C

8" (P

VC)

" (P

V C

12" (PVC)

8" (PVC)

" (P

V C

" (P

V C

" (P

V C

" (P

V C

" (P

V C

(P

V C

8" P V C

(P

V C

(P

V C

" (P

V C

8" (P V C

8" (P V C

8" (P V C

(P

V C

(P

V C

6" (P V C

" (P

V C

6" P V C

" (P

V C

8" (PVC)

6" P V C

" (P

V C

8" (P V C

6" (PVC)

8" (P

V C

8" P V C

(P

V C

01163

01143

01157

01142

01161

01159

01147

0017800179

05295

05294

05331

05341

05367

05351

05373

05356

05407

05352

05241

05424

05340

05354

05381

05375

05418

05415 05419

05224

05320

05361

05411

05388

05364

00016

8" (R

C

" (R

C

8" (

PVC)

8" (PVC)

8" R C

" (R

C

" (R

C

" (R

C

" (P

V C

" (P

V C

" (P

V C

8" R C

8" (R C

8" (R C)

8" (R C)

8" (R C)

8" (P

V C

8" (P

VC)

" (P

V C

" (S

02117

02162

02175

02179

02191

02203

02143

02114

02098

02195

02193

02182

02163

02157

02151

02144

02185

02160

02165

02199

02128

02154

01492

01483

01489

01493

01533

01549

0153401535

01496

05247

MH0749

V0068

V0398

V0383

V0568

V0267

V0266

V0566

V0397

V0567

V0707

V0708

V0709

V0638

COMM

COMM

COMM

COMM

E

E

E

E

E

E

E

E

E

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G

G R

GR

G R

G R

GR

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S S

S S

S S

S

S

S

S

S

S

S

S

S

SCO

SCO

SCO

SCO

SCO

SCO

SCO

SCO

SCO

SCO

SCO

W

W

W

W

W

W

W

W

W

W

W W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

WW

W

W

W

W

W

GC

ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww ww

SCO

SCO

SCO

SCO

SCO

SCO

SCO

SCOSCO

COMM

CMH

GEN

RESIDUAL PRESSURE = 72 PSI

STATIC PRESSURE = 86 PSI

TEST HYDRANT

FLOW = 1,260 GPM

FLOW HYDRANT NORTH

FLOW = 1,090 GPM

FLOW HYDRANT SOUTH

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

B R

IS

E N

O W

A Y

E. SUTHERLAND CIR.

DEVENS S

T.

JE

D B U R

G H D

R

CMH

CMH

CMH

CMH

CMH

B R

IS

E N

O W

A Y

E . S

U T

H E

R L A

N D C

IR

D E V E N S S

T.

JE

D B U R

G H D

R

Unknown" ()

Unkn ow n" (

W

MT. LA DIFENSA DR.

PRO

VI

DE

CO

M

FO

RT

DR.

PROVIDE COMFORT DR.

" (R

C

BOEBLINGEN RD.

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:12:37 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\FIRE HYDRANT FLOW TEST PLAN

A H

A

N E

F

IL

E N

A M

A H

A

N E

F

IL

E N

A M

R T C

A R

S O

N

C O

L O

R A

D O

O M

A H

A D

IS

T R

IC

T

F O

R T C

A R

S O

N

C O

L O

R A

D O

O M

A H

A D

IS

T R

IC

IL

E N

U M

B E

R

C

A P

IT

O L A

V

IL

E N

U M

B E

R

C

A P

IT

O L A

V

B Q

C U

.d g n

F C

B Q

C U

.d g n1 /2

/2

/2

/2

CU100

R

K E

R Z

M A

N

R

K E

R Z

M A

N

CU100

R

K E

R Z

M A

N

R

K E

R Z

M A

N

F

IR

E H

Y D

R A

N T F

L O

W T

E S

T L

O C

A T

IO

N P

L A

N F

IR

E H

Y D

R A

N T F

L O

W T

E S

T L

O C

A T

IO

N P

L A

N

100' 200'0

SCALE: 1" = 100'

N

KEYPLAN SCALE: 1" = 500'

N

W F -1

-R -0

W F -1

-R -0

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T

IL

D

IN

G

B U

IL

D

IN

G

W

INVERT=5858.58

DIAMETER=30"

MATERIAL=RCP

INVERT=5870.20

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.15

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5870.30

DIAMETER=8"

MATERIAL=PVC

RIM ELEVATION=5884.00

INVERT=5851.73

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5851.69

DIAMETER=6"

MATERIAL=HDPE

RIM ELEVATION=5855.91

INVERT=5853.46

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5858.11

INVERT=5855.40

DIAMETER=6"

MATERIAL=HDPE

INVERT=5853.26

DIAMETER=10"

MATERIAL=HDPE

RIM ELEVATION=5855.11

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5860.85

DIAMETER=18"

MATERIAL=CMP

INVERT=5858.62

DIAMETER=18"

MATERIAL=CMP

W W

W

W

CB

CBCB

CB

CBCB

G

G

S

T

S

CO

CP

CO

SANITARY SEWER LINE

BUILD MANHOLE OVER EXISTING

6" CLEANOUT

FIRE HYDRANT

FIRE HYDRANT

8" POST INDICATOR VALVE

AND GATE VALVE

WITH TAPPING TEE

WATER LINE LINE

CONNECT TO EXISTING

AND GATE VALVE

WITH TAPPING TEE

WATER LINE LINE

CONNECT TO EXISTING

CAP END OF TEE.

AND GATE VALVE.

WITH TAPPING TEE

WATER LINE LINE

CONNECT TO EXISTING

NEW COMM. MANHOLE

NEW COMM. MANHOLE

NEW COMM. MANHOLE

NEW COMM. MANHOLE

STND. F.O. & 100 PR. CU.

DUCT BANK WITH 24

EXISTING 24 STND. F.O. CABLES

SPLICE NEW 24 STND F.O. INTO

24 STND. F.O.

DUCT BANK WITH

EXISTING GAS LINE

CONNECT TO

SEE COMMUNICATIONS NOTE 2

SEE COMMUNICATIONS NOTE 1

SEE COMMUNICATIONS NOTE 4

SEE COMMUNICATIONS NOTE 3 S

O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

P

IV

8"W

6" S

CO

FW

DW

C C

C

C

"W

"W

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:13:36 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\FCBQCU101

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

CU101

F C

B Q

C U

.d g n

F C

B Q

C U

.d g n

CU101

W A

T E

R A

N D S

A N

IT

A R

Y S

E W

E R P

L A

N W

A T

E R A

N D S

A N

IT

A R

Y S

E W

E R P

L

/2

/2

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A N

S I

D

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T

OTHER APPURTENANCES NECESSARY TO CONSTRUCT THE FACTILITY.

REPLACEMENT AND EXACT LOCATIONS OF THE EXISTING UITLITIES AND

2. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFICATION, REMOVAL,

RESPONSIBLE FOR FINAL ROUTING AND COORDINATION OF ALL UTILITIES.

1. ROUTING SHOWN ON PLANS IS CONCEPTUAL ONLY. CONTRACTOR IS

UTILITY NOTES:

A R

E A

A R

E A

COMMUNICATIONS ROOM AS INDICATED. PROVIDE 1-4" CONDUIT WITH 3-1 1/4" INNERDUCT HDPE.

100-PAIR COPPER CABLE CA12-3, PAIR 2201-2300. FROM NEW MAINTENANCE HOLE TO FACILITY

WITH ONE (1) 24-STRANDS FIBER OPTIC CABLES (LABEL ONE FO 12-05, STRAND 25-48) AND A NEW

4. CONTRACTOR SHALL PROVIDE A NEW 4-4" PVC DUCT BANK CONCRETE AND ENCASEMENT

OPTIC CABLE TO EXISTING 24-STRAND FIBER OPTIC CABLE AT NEW MAINTENANCE HOLE.

RE-ROUTE FIBER OPTIC CABLE TO NEW MAINTENANCE HOLE. SPLICE NEW 24-STRAND FIBER

3. CONTRACTOR SHALL LOCATE EXISTING DIRECT-BURIED 24-STRAND FIBER OPTIC CABLE.

INNERDUCT HDPE.

MAINTENANCE HOLE TO NEW MAINTENANCE HOLE. PROVIDE 1-4" CONDUIT WITH 3-1 1/4"

ENCASEMENT WITH 24-STRANDS FIBER OPTIC CABLE FO09T, STRAND 1-24 FROM NEW

2. CONTRACTOR SHALL PROVIDE A NEW 2-4" PVC DUCT BANK CONCRETE AND

INNERDUCT HDPE.

MAINTENANCE HOLE TO NEW MAINTENANCE HOLE. PROVIDE 2-4" CONDUIT WITH 3-1 1/4"

100-PAIR COPPER CABLE CA12-3, PAIR 2201-2300 FROM EXISTING MH0749 THRU NEW

ONE FO 12-05, STRAND 25-48 AND OTHER CABLE FO09T STRAND 1-24) AND A NEW

AND ENCASEMENT WITH TWO (2) 24-STRANDS FIBER OPTIC CABLES (LABEL

1. CONTRACTOR SHALL PROVIDE A NEW 6-4" PVC DUCT BANK CONCRETE

COMMUNICATIONS NOTES:

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

BUILDING

A

D T

O E

L Z R

O A

D

W

INVERT=5851.77

DIAMETER=30"

MATERIAL=RCP

RIM ELEVATION=5857.97

INVERT=5850.56

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5850.57

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5855.37

INVERT=5845.88

DIAMETER=15"

MATERIAL=RCP

RIM ELEVATION=5820.28

INVERT=5866.66

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.34

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.26

DIAMETER=24"

MATERIAL=CMP

INVERT=5866.35

DIAMETER=24"

MATERIAL=CMP

NO PRKNG FIRE LANE

MRS3113

544 5882.461

CC

CPE

E

CP

MH 0749

EXISTING

SEE COMMUNICATIONS NOTE 1

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

101102

SCALE: 1" = 40'

N

40' 80'0

N

KEYPLAN SCALE: 1" = 500'

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:14:04 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\FCBQCU102

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

C U

.d g n

F C

B Q

C U

.d g n

OTHER APPURTENANCES NECESSARY TO CONSTRUCT THE FACTILITY.

REPLACEMENT AND EXACT LOCATIONS OF THE EXISTING UITLITIES AND

2. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFICATION, REMOVAL,

RESPONSIBLE FOR FINAL ROUTING AND COORDINATION OF ALL UTILITIES.

1. ROUTING SHOWN ON PLANS IS CONCEPTUAL ONLY. CONTRACTOR IS

UTILITY NOTES:

A R

E A

A R

E A

CU102CU102

W A

T E

R A

N D S

A N

IT

A R

Y S

E W

E R P

L A

N W

A T

E R A

N D S

A N

IT

A R

Y S

E W

E R P

L A

N

/2

/2

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

A N

S I

D

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T

PROVIDE 2-4" CONDUIT WITH 3-1 1/4" INNERDUCT HDPE.

EXISTING MH0749 THRU NEW MAINTENANCE HOLE TO NEW MAINTENANCE HOLE.

CABLE FO09T STRAND 1-24) AND A NEW 100-PAIR COPPER CABLE CA12-3, PAIR 2201-2300 FROM

WITH TWO (2) 24-STRANDS FIBER OPTIC CABLES (LABEL ONE FO 12-05, STRAND 25-48 AND OTHER

1. CONTRACTOR SHALL PROVIDE A NEW 6-4" PVC DUCT BANK CONCRETE AND ENCASEMENT

COMMUNICATIONS NOTES:

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

NON-METALLIC PIPE

WELD

EXOTHERMIC

NON-METALLIC PIPE METALLIC PIPE

METALLIC PIPE

NEW NON-

METALLIC PIPE

EXISTING NON-

TRACER WIRE

NEW

SPLICE

TRACER WIRE

EXISTING

OF COPPER

CLAMP-TYPE FITTING

WELD OR APPROVED

MOLDED EXOTHERMIC

PIPE

NON-METTALIC

EXISTING

METALLIC PIPE

NEW NON-

STEEL GROUND ROD

LONG COPPER-CLAD

3/8" DIA. 5-FOOT

GRADE

FINISHED

SUBGRADE

PAVEMENT

TAPE

IDENTIFICATION

WARNING AND

UTILITY PIPE

NON-METALLIC

FIRE HYDRANT

VALVE

NON-METALLIC PIPE

STORM MANHOLE

SANITARY OR

PIPE

NON-METALLIC

PIPE

NON-METALLIC

AREA INLET

PIPE

NON-METALLIC

TRACER WIRE

TEST STATION

TEST STATION

WIRE

TRACER

WIRE

TRACER

TEST STATION

TRACER WIRE

WIRE

TRACER

TRACER WIRE TRACER WIRE

TEST STATIONTEST STATIONTEST STATION

TRACER WIRE

TEST STATION

TRACER WIRE

AREA INLET

CURB OR

TRACER WIRE

PIPE

NON-METALLIC

ROOF DRAIN PIPE

NON-METALLIC

STORM DRAIN PIPE

NON-METALLIC

TEST STATION

END OF LINE

CLEANOUT AT

STORM DRAIN

WIRE

TRACER

DRAIN LINE

WIRE ALONG ROOF

DOUBLE BACK TRACER

WIRE

TRACER

STATION

TEST

WIRE

TRACER

PIPE

GAS OR WATER

NON-METALLIC

STATION

TEST

WATER PIPE

GAS OR

METALLIC

WIRE

TRACER

WELD

EXOTHERMIC

PIPE

GAS OR WATER

NON-METALLIC

(EXCEPT GAS LINE)

TRACER WIRE

(GAS LINE)

TRACER WIRE

LOCKING LID

CAST IRON

BLOCK W/SHUNT

2 POINT TERMINAL

INSIDE

TWO FEET OF WIRE

COIL APPROXIMATELY

15-18 INCH LONG

2-1/2 TO 4-INCH I.D.,

PLASTIC BOX APPROX.

WIRE (TYP.)

TRACER

S O

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:14:29 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\TRACER WIRE DETAILS

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

C U

.d g n

F C

B Q

C U

.d g n

W .C

D A

V E

N P

O R

T

IN

S T

A L L

A T

IO

N D

E T

A

IL

S

CU501

I.

K

N U

T S

O N

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T

IN

S T

A L L

A T

IO

N D

E T

A

IL

S

CU501

I.

K

N U

T S

O N

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

U T

IL

IT

Y T

R A

C E

R W

IR

E

U T

IL

IT

Y T

R A

C E

R W

IR

E

W F -1

-R -0

NO SCALE

TRACER WIRE INSTALLATION DETAILS

INTERMEDIATE TEST STATION TEST STATION AT PIPE CONNECTION TEST STATION AT PIPE CONNECTION TEST STATION AT PIPE CONNECTION

TRACER WIRE INSTALLATION DETAIL

TEST STATION AT FIRE HYDRANT TRACER WIRE AT ROOF DRAIN TEST STATION AT TEE TEST STATION AT TEE

TEST STATION AT MANHOLE TEST STATION AT INLET TRACER WIRE AT INLET

"1

NOTE

ALONG NON-METALLIC UTILITY LINES.

INTERVALS NOT TO EXCEED 400 FEET

TEST STATIONS SHALL BE INSTALLED AT

NOTE

PIPE.

NON-METALLIC PIPE IS CONNECTED TO A METALLIC

TEST STATION SHALL BE INSTALLED WHERE NEW

NOTE

NON-METALLIC PIPE WITH TRACER WIRE.

NON-METALLIC PIPE IS CONNECTED TO AN EXISTING

TEST STATION SHALL BE INSTALLED WHERE NEW

NOTE

NON-METALLIC PIPE WITHOUT TRACER WIRE.

NON-METALLIC PIPE IS CONNECTED TO AN EXISTING

TEST STATION SHALL BE INSTALLED WHERE NEW

NOTES:

GENERAL NOTES:

TEST STATION LOCATIONS:

NOTE NOTE

EXCEPT AT THE END OF THELINE.

REQUIRED AT STORM DRAIN LINE CLEANOUTS,

ARE NOT REQUIRED. TEST STATIONS ARE NOT

BE CONTINOUS AROUND INLET AND TEST STATIONS

DRAIN CURB OR AREA INLET, TRACER WIRE SHALL

IF 2 NON-METALLIC PIPES ARE ENTERING A STORM

NOTE

PHONE 800-870-5088

HANDLEY INDUSTRIES

2 INCH CATHODIC TEST STATION

PHONE 610-367-5062

C.P. TEST SERVICES

C.P. MINI BOX OR GLENN 4 TEST STATION

FOLLOWING PRODUCTS OR AN APPROVED EQUAL:

STATION". TEST STATIONS SHALL BE ONE OF THE

2. TEST STATION LID SHALL BE MARKED "TEST" OR TEST

BLOCK W/O SHUNT.

1. TEST STATIONS WITH 3 WIRES SHALL HAVE 4 POINT

TEST STATION DETAIL

4"

MIN.

REQUIREMENTS.

4. SEE SECTION 31 00 00 "EARTHWORK" FOR ADDITIONAL

ABOVE THE UTILITY.

WIRE SHALL BE REPAIRED PRIOR TO COMPLETING BACKFILL

MATERIAL OVER THE WIRE. ANY DISCONTINUITIES IN THE

CONTINUITY AFTER PLACING THE FIRST LIFT OF BACKFILL

3. THE CONTRACTOR SHALL TEST THE TRACER WIRE FOR

MARKING TAPE COLOR FOR EACH TYPE OF UTILITY.

LOCATIONS). WIRE INSULATION COLOR SHALL MATCH

RHW, RHW-2, THHW, THW, XHHW-2 OR HMWPE (WET

FOR ALL OTHER UTILITY LINES. WIRE SHALL BE TYPE TW,

STRAND, SOLID COPPER 6 AWG FOR GAS LINES AND 12 AWG

2. TRACER WIRE SHALL BE INSULATED STRANDED OR SINGLE

OF WIRE.

TRACER WIRES WITH 1 LB ANODE FOR EVERY 400 FEET

OF NEW CULVERTS. PROTECT UNDERGROUND UTILITY

TRACER WIRE DOES NOT HAVE TO BE INSTALLED ON TOP

DUCT TAPE EVERY 3 FEET FOR ALL OTHER UTILITY LINES.

SHALL BE PLACED ON TOP OF PIPE AND SECURED WITH

INSTALLED 6 INCHES ABOVE GAS LINES. TRACER WIRE

NON-METALLIC UTILITY LINES. TRACER WIRE SHALL BE

1. TRACER WIRE SHALL BE INSTALLED ABOVE ALL NEW

400-FOOT MAXIMUM INTERVALS ALONG GAS LINE

ABRUPT CHANGES IN DIRECTION

CONNECTIONS TO EXISTING GAS LINES

5 FEET FROM BUILDING

LOCATIONS ALONG NON-METALLIC GAS LINES:

4. TEST STATIONS SHALL BE INSTALLED AT THE FOLLOWING

INLETS AND CLEANOUTS AT END OF LINE

AREA OR CURB INLETS WITH 3 OR MORE PIPES

FLARED END SECTION OR HEADWALL

MANHOLES

LOCATIONS ALONG NON-METALLIC STORM DRAIN LINES:

3. TEST STATIONS SHALL BE INSTALLED AT THE FOLLOWING

- FIRE HYDRANTS

- 400-FOOT MAXIMUM INTERVALS ALONG WATERLINE

- ABRUPT CHANGES IN DIRECTION

- CONNECTIONS TO EXISTING WATERLINES

- 5 FEET FROM BUILDING

LOCATIONS ALONG NON-METALLIC WATER LINES:

2. TEST STATIONS SHALL BE INSTALLED AT THE FOLLOWING

- AT EVERY 400 LINEAR FEET OF EACH FORCE MAIN

(AT DISCHARGE POINT)

- AT EACH SEWER FORCE MAIN LIFT STATION

- AT EACH SANITARY SEWER MANHOLE

- AT EACH BUILDING SEWER CLEANOUT

FORCE MAINS.

LOCATIONS ALONG NON-METALLIC SANITARY SEWERS OR

1. TEST STATIONS SHALL BE INSTALLED AT THE FOLLOWING

OR STORM DRAIN MANHOLES.

NON-METALLIC PIPE ENTERING SANITARY SEWER

A TEST STATION SHALL BE INSTALLED FOR EACH

NON-METALLIC PIPE ENTERING THE INLET.

A TEST STATION SHALL BE INSTALLED FOR EACH

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T

L

IC

IT

A T

IO

N N

O

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:15:52 AM 12/20/2018

...\FC\FCBQ\40000 Design Products\CAD_BIM\_Sheets\UTILITY CLEARANCE MATRIX

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R T C

A R

S O

N

C O

L O

R A

A H

A

N E

C

A P

IT

O L A

V E

O M

A H

A D

IS

T R

IC

T

F

IL

E N

U M

B E

R

F

IL

E N

A M

E

F C

B Q

C U

.d g n

F C

B Q

C U

.d g n

W .C

D A

V E

N P

O R

T

CU600

I.

K

N U

T S

O N

A F

A N

C

IU

L L

O

W .C

D A

V E

N P

O R

T

W .C

D A

V E

N P

O R

T

CU600

I.

K

N U

T S

O N

W .C

D A

V E

N P

O R

T

A F

A N

C

IU

L L

O

A N

S I

D

/2

/2

U T

IL

IT

Y C

L E

A R

A N

C E M

A T

R

IX

U T

IL

IT

Y C

L E

A R

A N

C E M

A T

R

IX

F O

R T C

A R

S O

N U

N D

E G

R O

U N

D F

O R

T C

A R

S O

N U

N D

E G

R O

U N

D

P N

F

Y

S O

F H

U M

A N P

E R

F O

R M

A N

C E T

R A

IN

IN

G C

E N

T E

R

W F -1

-R -0

REF.DW

E

F

A-200

A-200

A-200

A-200

104B

EXTERIOR

CANOPY

ABOVE

J

F

H

K

C

64' - 4" 57' - 4" 42' - 4" 4' - 0"

104A

102A

102B

102C

102D

116114

121F

121G

121A

121B

121C

121D

121E

LL

A

EE

J

J

J

J

CC

A

EE

II

GG

NN OO PP

G

G

L

BID OPTION - CONSTRUCT ADDITIONAL

4,000 SF MINIMUM TO OPEN ACTIVITY AREA.

M N O

P

106C 106B 106A

108A108B

118A

24' - 0"

BID OPTION - CONSTRUCT ADDITIONAL 4,000 SF

+/- 33' - 4"

BID OPTION - CONSTRUCT ADDITIONAL 8,000 SF

+/- 66' - 8"

BID OPTION - CONSTRUCT ADDITIONAL

8,000 SF MINIMUM TO OPEN ACTIVITY

AREA.

M

IN

B

B

B

B

C

I

D D

E

FF

MM MM

DD

DD

CC

FF

QQ

HH

QQ

JJ

KK

HH

HH

HH

HH HH HH

HH

HH

II

JJ

JJ

JJ

JJ

JJ

RR

QQ

SS

SS

TT

OPEN ACTIVITY AREA SHALL CLEARSPAN

EXCEPT FOR COLUMNS ALONG THIS LINE AS

NEEDED, NOT TO EXCEED TWO COLUMNS

WITHIN OPEN ACTIVITY AREA

IF ADDITIONAL SQUARE FOOTAGE IS

AWARDED, UP TO TWO TOTAL INTERIOR

COLUMN LINES ARE ALLOWED, FOR A

MAXIMUM OF FOUR INTERIOR COLUMNS, TWO

PER LINE.

QQ

DD

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-110

F

IR

S T

F L O

O R

P L A

N

F O

R T

C A

R S

O N

C

O L

O R

A D

O

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

O M

A H

A N

E

A W

A L Z

A W

A L Z

B G

O R

U P

B G

O R

U P

/2 /2

W

F

-1

-R -0

S O

F H

U M

A N

P E

R F

O R

M A

N C

E T

R A

IN

IN

G C

E N

T E

R P

N

F Y

3/32" = 1'-0"A-110

1 1ST FLOOR PLAN

SCOPE:

TOTAL BUILDING SQUARE FOOTAGE - (FULL-SCOPE): 26,622 SF

TOTAL CANOPY SQUARE FOOTAGE - (HALF-SCOPE): 30 SF

TOTAL BID OPTION PLAN SQUARE FOOTAGE - (FULL-SCOPE): 8,072 SF

TOTAL EQUIVALENT FULL-SCOPE SQUARE FOOTAGE: 34,724 SF

DD1391 ALLOWABLE SQUARE FOOTAGE: 34,724 SF

8'0 4' 16'

PLAN NORTH

KEYNOTES - BUILDING ACCESSORIES

MARK DESCRIPTION

AA WALL MOUNTED TV (FF&E)

BB HEAVY DUTY BUILT IN SHELVES

CC COPIER/PRINTER (N.I.C.)

DD SHREDDER (N.I.C.)

EE FULL SIZE REFRIGERATOR (FF&E)

FF OVEN W/ RANGE TOP

GG UNDERCOUNTER DISHWASHER

HH 6' X 4' MARKERBOARD

II 8' X 4' MARKERBOARD

JJ 4' X 3' MARKERBOARD

KK 4' X 3' TACKBOARD

LL MOP HOLDER W/ SHELF

MM ACCESSIBLE LOCKER BENCH

NN TREADMILL THERAPY POOL (THERAPY POOL BID

OPTION)

OO HOT THERAPY POOL (THERAPY POOL BID OPTION)

PP COLD THERAPY POOL (THERAPY POOL BID

OPTION)

QQ 75" MONITOR (A/V EQUIPMENT BID) AND TV WALL

MOUNT (BASE BID)

RR 36" MONITOR (A/V EQUIPMENT BID) AND TV WALL

MOUNT (BASE BID)

SS DEFIBRILATOR CABINET

TT CEILING MOUNTED PROJECTION SCREEN

KEYNOTES - GENERAL

MARK DESCRIPTION

A UPPER AND LOWER CABINETS W/ SINK

B WATER COOLERS (2) W/ BOTTLE FILLER - ABA

COMPLIANT

C 10' WIDE X 10' HIGH SECTIONAL OVERHEAD DOOR

D ACCESSIBLE SHOWER W/ SHOWER ROD AND CURTAIN

E TWENTY (20) SINGLE TIER LOCKERS

F JANITORS SINK

G STORAGE CUBBIES AND COAT HOOKS

H VERTICALLY RETRACTABLE WALL

I RESTAURANT STYLE DOUBLE BASIN STAINLESS STEEL

SINK

J STRUCTURAL STOOP

K BOULDERING WALL - BID OPTION

L OSHA COMPLIANT ACCESS LADDER AND HATCH

M CARDIO AREA

N FREE WEIGHT AREA

O WEIGHT RACK AREA

P EXERCISE BALL AREA AND BALL WALL

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

ROOM SCHEDULE

ROOM NO ROOM NAME AREA

101 VEST. 90 SF

102A CORR. 254 SF

102B CORR. 142 SF

102C CORR. 619 SF

102D CORR. 142 SF

103 CUBBIES AREA 221 SF

104A MULTIPURPOSE ROOM A 465 SF

104B MULTIPURPOSE ROOM B 454 SF

105 TELECOMM 131 SF

106A UNISEX TOILET 72 SF

106B UNISEX TOILET 72 SF

106C UNISEX TOILET 72 SF

107 STAFF LOCKERS 132 SF

108A STAFF TOILET 98 SF

108B STAFF TOILET 98 SF

109 CONFERENCE ROOM 304 SF

110 COUNSELING 174 SF

111 STAFF BREAK ROOM 95 SF

112 JAN. 56 SF

113 TRAINERS OFFICE 433 SF

114 DIRECTOR'S OFFICE 139 SF

115 DIETICIAN OFFICE 119 SF

116 MENTAL PERFORMANCE OFFICE 119 SF

117 STRETCHING AREA 504 SF

118 HYDRO THERAPY 1052 SF

118A HYDRO THERAPY TOILET 111 SF

119 ELEC 47 SF

120 SPORTS MEDICINE LOBBY 200 SF

121 SPORTS MEDICINE TREATMENT AREA 1549 SF

121A EXAM ROOM 189 SF

121B EXAM ROOM 189 SF

121C EXAM ROOM 189 SF

121D EXAM ROOM 189 SF

121E EXAM ROOM 189 SF

121F STORAGE 280 SF

121G LAUNDRY ROOM 139 SF

122 OPEN ACTIVITY AREA 14485 SF

123 TRAINING EQUIPMENT STOR. 340 SF

124 MECHANICAL 839 SF

125 ELEC 277 SF

FIRST FLOOR PLAN

100' - 0"

SOLDIER COURSE

FACE BRICK

METAL COPING, TYP.

RUNNING BOND

FACE BRICK

CAST STONE TRIM

CAST STONE

SILL, TYP.

STOREFRONT ENTRANCE WITH

FULL LITE GLASS DOORS

SPLIT-FACED CMU

CLR ANODIZED ALUMINUM EXTERIOR SUN CONTROL

DEVICE, EAST, SOUTH AND WEST FACING WINDOWS

METAL CANOPY WITH

METAL SOFFIT

METAL COPING, TYP.

METAL COPING, TYP.

1/2" / 1'-0"

INSULATED METAL

WALL PANELS

MEMBRANE

ROOF

INSULATED METAL

WALL PANELS

FIRST FLOOR PLAN

100' - 0"

SOLDIER COURSE FACE BRICK

METAL COPING, TYP.

RUNNING BOND FACE BRICK

CAST STONE TRIM

SPLIT-FACED CMU

CLR ANODIZED ALUMINUM EXTERIOR SUN CONTROL

DEVICE, EAST, SOUTH AND WEST FACING WINDOWS

MEMBRANE ROOF

BID OPTION - ALTERNATE FLOOR PLAN "B"

BID OPTION - ALTERNATE FLOOR PLAN "A"

FIRST FLOOR PLAN

100' - 0"

SOLDIER COURSE FACE BRICK

METAL COPING

RUNNING BOND FACE BRICK

CAST STONE TRIM

SPLIT-FACED CMU

FULL GLASS HIGH LIFT

SECTIONAL OVERHEAD DOOR

CLR ANODIZED ALUMINUM

EXTERIOR SUN CONTROL

DEVICE, EAST, SOUTH AND

WEST FACING WINDOWS

1/2" / 1'-0"

MEMBRANE

ROOF

METAL COPING

INSULATED METAL

WALL PANELS

CAST STONE

SILL, TYP.

SEMI-OPAQUE

GLAZING, TYP.

CLEAR

GLAZING, TYP.

FULL GLASS HIGH LIFT

SECTIONAL OVERHEAD DOOR

FIRST FLOOR PLAN

100' - 0"

INSULATED METAL

WALL PANELS

HIGH LIFT SECTIONAL

OVERHEAD DOOR

METAL COPING

CLEAR ANODIZED

ALUMINUM CURTAINWALL

BID OPTION - ALTERNATE FLOOR PLAN "A"

BID OPTION - ALTERNATE FLOOR PLAN "B"

INSULATED METAL

WALL PANELS

SOLDIER COURSE FACE BRICK

METAL COPING

RUNNING BOND FACE BRICK

CAST STONE TRIM

SPLIT-FACED CMU

SEMI-OPAQUE

GLAZING, TYP.

CLEAR

GLAZING, TYP.

METAL COPING

METAL CANOPY

WITH METAL SOFFIT

CAST STONE

SILL, TYP.

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-200

E L E

V A

T

IO

N S

F O

R T

C A

R S

O N

C

O L

O R

A D

O

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

O M

A H

A N

E

A W

A L Z

A W

A L Z

B G

O R

U P

B G

O R

U P

/2 /2

W

F

-1

-R -0

S O

F H

U M

A N

P E

R F

O R

M A

N C

E T

R A

IN

IN

G C

E N

T E

R P

N

F Y

3/32" = 1'-0"A-200

1 EAST COMPOSITE ELEVATION

3/32" = 1'-0"A-200

2 SOUTH COMPOSITE ELEVATION

3/32" = 1'-0"A-200

3 WEST COMPOSITE ELEVATION

3/32" = 1'-0"A-200

4 NORTH COMPOSITE ELEVATION

GENERAL NOTES

1. BUILDING ELEVATION HEIGHTS ARE FOR REFERENCE ONLY.

FINAL HEIGHTS MAY NEED TO BE ADJUSTED TO

ACCOMODATE STRUCTURAL, MECHANICAL, AND

ELECTRICAL CONDITIONS.

2. PROVIDE GUTTERS AND OPEN FACED DOWNSPOUTS TO

DRAIN ROOF, OR INTERNAL ROOF DRAINS. ARRANGE

DOWNSPOUTS TO AVOID OPENINGS AND WITH BUILDING

AESTHETICS IN MIND. COORDINATE DOWNSPOUT AND

INTERNAL DRAIN TERMINATION WITH SITE STORMWATER

MANAGEMENT CONCEPT. DOWNSPOUTS TERMINATING

ABOVE GRADE SHALL BE PROVIDED WITH CONCRETE

SPLASHBLOCKS. DOWNSPOUTS TERMINATING BELOW

GRADE SHALL BE PROVIDE WITH BOOTS.

3. PROVIDED ELEVATIONS REPRESENT A BASELINE

AESTHETIC. THE CONTRACTOR SHALL FULLY DEVELOP

EXTERIOR AESTHETICS, MATERIALS AND DETAILING.

4. THE EXTERIOR WALLS OF BID OPTIONS - "CONSTRUCT

ADDITIONAL 4,000 SF" AND "CONSTRUCT ADDITIONAL 8,000

SF" SHALL MATCH THE EXTERIOR FINISHES OF THE BASE

BID WALLS THEY ARE ADJACENT TO.

5. THE WEST WALLS OF BID OPTIONS - "CONSTRUCT

ADDITIONAL 4,000 SF" AND "CONSTRUCT ADDITIONAL 8,000

SF" SHALL HAVE SUN CONTROL DEVICES, DOORS AND

WINDOWS MATCH THE BASE BID WEST WALL ELEVATION IN

CONFIGURATION AND MATERIALS.

6. THE SOUTH AND NORTH WALLS OF BID OPTIONS -

"CONSTRUCT ADDITIONAL 4,000 SF" AND "CONSTRUCT

ADDITIONAL 8,000 SF" SHALL HAVE GLAZING THAT IS SIMILAR

IN CONFIGURATION TO THE GLAZING SHOWN ON THE BASE

BID FLOOR PLANS FOR THE OPEN ACTIVITY AREA.

7. ADDITIONAL DAYLIGHTING FEATURES MAY BE REQUIRED TO

MEET DAYLIGHTING REQUIREMENTS OF 01 82 00. THESE

FEATURES ARE NOT SHOWN AND ARE THE RESPONSIBILITY

OF THE CONTRACTOR FOR DESIGN AND PLACEMENT TO

MEET DAYLIGHTING LEVELS REQUIRED.

0 20'10'5'

M A

R K

D E

S C

R

IP

T

IO

N D

A

ROOM FINISH SCHEDULE LEGEND

AT ARTIFICIAL TURF

ATC ACOUSTICAL TILE CEILING

CT CERAMIC TILE

CW CURTAIN WALL/STOREFRONT

EFM ENTRANCE FLOOR MAT

EXP EXPOSED STRUCTURE

GWB GYPSUM WALL BOARD

PCONC PRECAST CONCRETE

PNT PAINT

PT PORCELAIN TILE

RAF RUBBER ATHLETIC FLOORING

RB RESILIENT BASE

RF RESINOUS FLOORING

SCONC SEALED CONCRETE

SSM SOLID SURFACE MATERIAL

VAF VINYL COATED ATHLETIC FLOORING

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I 'D

F

IL

E

N A

M E

IS

S

U E

D A

T E

C O

N T

R A

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

U M

B E

R

1 2 3 4 5

D

C

B

A

A-600

R O

O M

F

IN

IS

H

S C

H E

D U

L E

F O

R T

C A

R S

O N

C

O L

O R

A D

O

O M

A H

A D

IS

T

R

IC

T C

A P

IT

O

L A

V E

O M

A H

A N

E

A W

A L Z

A W

A L Z

B G

O R

U P

B G

O R

U P

/2 /2

W

F

-1

-R -0

S O

F H

U M

A N

P E

R F

O R

M A

N C

E T

R A

IN

IN

G C

E N

T E

R P

N

F Y

FINISH SCHEDULE - BASE BID

ROOM NO ROOM NAME NET AREA

FLOOR

FINISH

BASE

FINISH WALL FINISH

CEILING

FINISH

CEILING

HEIGHT NOTES

101 VEST. 90 SF EFM RB GWB/PNT GWB 9'-0" 1

102A CORR. 254 SF VAF RB GWB/PNT ATC 9'-0" 1

102B CORR. 142 SF VAF RB GWB/PNT ATC 9'-0" 1

102C CORR. 619 SF VAF RB GWB/PNT ATC 9'-0" 1

102D CORR. 142 SF VAF RB GWB/PNT ATC 9'-0" 1

103 CUBBIES AREA 221 SF VAF RB GWB/PNT ATC 9'-0"

104A MULTIPURPOSE ROOM A 465 SF VAF/PT RB/PT GWB/PNT ATC 10'-0" 10, 15

104B MULTIPURPOSE ROOM B 454 SF VAF RB GWB/PNT ATC 10'-0" 9

105 TELECOMM 131 SF SCONC RB GWB/PNT EXP/PNT - 5

106A UNISEX TOILET 72 SF PT PT GWB/PNT/PT WAINSCOT GWB 9'-0" 2, 6, 7

106B UNISEX TOILET 72 SF PT PT GWB/PNT/PT WAINSCOT GWB 9'-0" 2, 6, 7

106C UNISEX TOILET 72 SF PT PT GWB/PNT/PT WAINSCOT GWB 9'-0" 2, 6, 7

107 STAFF LOCKERS 132 SF PT PT GWB/PNT ATC 9'-0" 1

108A STAFF TOILET 98 SF PT PT GWB/PNT/PT WAINSCOT GWB 9'-0" 2, 6, 7

108B STAFF TOILET 98 SF PT PT GWB/PNT/PT WAINSCOT GWB 9'-0" 2, 6, 7

109 CONFERENCE ROOM 304 SF VAF RB GWB/PNT ATC 9'-0" 11

110 COUNSELING 174 SF VAF RB GWB/PNT ATC 9'-0"

111 STAFF BREAK ROOM 95 SF VAF RB GWB/PNT ATC 9'-0"

112 JAN. 56 SF SCONC RB GWB/PNT EXP/PNT - 3, 4, 6

113 TRAINERS OFFICE 433 SF VAF RB GWB/PNT ATC 9'-0"

114 DIRECTOR'S OFFICE 139 SF VAF RB GWB/PNT ATC 9'-0" 12

115 DIETICIAN OFFICE 119 SF VAF RB GWB/PNT ATC 9'-0" 12

116 MENTAL PERFORMANCE OFFICE 119 SF VAF RB GWB/PNT ATC 9'-0" 13

117 STRETCHING AREA 504 SF RAF RB GWB/PNT ATC 9'-0" 1

118 HYDRO THERAPY 1052 SF PT PT GWB/PNT ATC 10'-0" 14

118A HYDRO THERAPY TOILET 111 SF PT PT GWB/PNT/PT WAINSCOT ATC 9'-0" 2, 6, 7

119 ELEC 47 SF SCONC RB PCONC/GWB/PNT EXP/PNT -

120 SPORTS MEDICINE LOBBY 200 SF VAF RB GWB/PNT ATC 10'-0"

121 SPORTS MEDICINE TREATMENT AREA 1549 SF VAF RB GWB/PNT ATC 10'-0" 1

121A EXAM ROOM 189 SF VAF RB GWB/PNT ATC 10'-0" 1

121B EXAM ROOM 189 SF VAF RB GWB/PNT ATC 10'-0" 1

121C EXAM ROOM 189 SF VAF RB GWB/PNT ATC 10'-0" 1

121D EXAM ROOM 189 SF VAF RB GWB/PNT ATC 10'-0" 1

121E EXAM ROOM 189 SF VAF RB GWB/PNT ATC 10'-0" 1

121F STORAGE 280 SF SCONC RB GWB/PNT EXP/PNT -

121G LAUNDRY ROOM 139 SF PT PT GWB/PNT/PT WAINSCOT ATC 9'-0"

122 OPEN ACTIVITY AREA 14485 SF RAF/AT RB PCONC/GWB/PNT EXP/PNT - 1, 8

123 TRAINING EQUIPMENT STOR. 340 SF SCONC RB PCONC/GWB/PNT ATC 9'-0"

124 MECHANICAL 839 SF SCONC RB PCONC/GWB/PNT EXP/PNT -

125 ELEC 277 SF SCONC RB PCONC/GWB/PNT EXP/PNT - ROOM FINISH NOTES:

1. PROVIDE IMPACT RESISTANT GWB FROM TOP OF CONCRETE FLOOR SLAB TO MIN. 8'-0" ABOVE FINISHED FLOOR.

2. PROVIDE GLASS-MAT GWB ON WALLS OF TOILET AND SHOWER ROOMS.

3. PROVIDE MOISTURE-RESISTANT GWB ON PLUMBING WALLS.

4. PROVIDE 5'-0" HIGH MINIMUM CT WAINSCOT SURROUND AT MOP SINK.

5. PROVIDE 3/4" FIRE RATED TELECOMMUNICATIONS BACKERBOARDS ON ALL WALLS. SEE SPECIFICATIONS.

6. PROVIDE MOISTURE-RESISTANT GWB FOR CEILING.

7. PROVIDE 5'-0" HIGH MINIMUM PT WAINSCOT.

8. PROVIDE MINIMUM 25'-0" CLEAR HEIGHT FROM FINISH FLOOR TO UNDERSIDE OF FIXTURES AND STRUCTURE AT THE TURF

AREA, AND A MINIMUM 16'-0" CLEAR HEIGHT FROM FINISH FLOOR TO UNDERSIDE OF FIXTURES AND STRUCTURE FOR THE

REMAINDER OF THE SPACE.

9. PROVIDE DRY ERASE MAGNETIC WALLCOVERING ON THE SOUTH WALL AND WEST WALL, EXCEPT ON PORTION OF WALL

BETWEEN DOORS.

10. PROVIDE DRY ERASE MAGNETIC WALLCOVERING ON WEST WALL, EXCEPT ON PORTION OF WALL BETWEEN DOORS AND

SHALL STOP 1'-0" AWAY FROM BASE CABINETS.

11. PROVIDE DRY ERASE MAGNETIC WALLCOVERING ON ALL WALLS.

12. PROVIDE DRY ERASE MAGNETIC WALLCOVERING ON EAST WALL.

13. PROVIDE DRY ERASE MAGNETIC WALLCOVERING ON WEST WALL.

14. PROVIDE MOISTURE RESISTANT CEILING TILES.

15. PROVIDE PORCELAIN TILE 7'-0" DEEP IN FRONT OF BASE CABINETS, RUNNING FULL WIDTH OF ROOM.

GENERAL NOTES NOTES:

1. NORTH, SOUTH, EAST & WEST AS NOTED ON SCHEDULE SHALL BE ACCORDANCE WITH PLAN NORTH AS INDICATED ON PLANS.

2. CEILING HEIGHTS/ELEVATIONS IDENTIFIED IN ROOM FINISH SCHEDULE ARE HEIGHTS ABOVE THEIR RESPECTIVE FINISHED FLOORS.

3. ALL PRECAST CONCRETE WALLS SHALL BE LEFT UNPAINTED UNLESS NOTED OTHERWISE IN THE ROOM FINISHE SCHEDULE, DRAWINGS, OR SPECIFICATIONS.

4. PROVIDE STAINLESS STEEL CORNER GUARDS AT ALL GYPSUM WALL BOARD FINISHED CORNERS.

M…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.