FUNCTIONAL AREA LEGEND

2 SWS

8 SES

11 SWS

460 OG - BID OPTION

BUILDING SUPPORT

BUILDING SUPPORT - OPTION

CANOPY

CIRCULATION

CIRCULATION - OPTION

CLASSROOM

CORE NODE

DEV & TESTING

MEETING

MEETING - OPTION

OGI

OGV

OGX

OSS

OSS INSTRUCTORS

PERSONNEL SUPPORT

SST

WEAPONS & TACTICS

0'

-0

CORE NODE

OGX

11 SWS

OSS8 SES

OSS INSTRUCTORS

SST

OGI OGV

CANOPY

CANOPY

OPEN STORAGE SECURE AREA

ENLARGED AREA PLAN "A" - SEE SHEET A-111 ENLARGED AREA PLAN "B" - SEE SHEET A-1121/ A-

1/ A-

1/ A-

1/ A-

A-201

2 SWS

'-0

'-0

'-0

0'

-0

34'-0" 20'-0" 20'-0"

'-0

N O

T E

SE

E

'-0

0'

-0

A-201 2 A-2013

A-201

6'-0"

460 OG - BID

OPTION

'-6

'-0

'-6

8'-0"

BID OPTION - SEE NOTES

COMMAND SUITE

SE

E

N O

TE

S

C O

M M

AN

D

S U

IT

E

BI

D

O

PT

IO

N

CLASSROOM

MEETING

CLASSROOM

250'-0" 40'-0" 158'-0"

448'-0"

'-0

'-0

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-110

C O

N C

EP

T

FL

O

O R

P

LA

N

C O

M

PO

SI

TE

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

0 10' 20' 40'

PLAN NORTH

3/64" = 1'-0"A-110

1 COMPOSITE FUNCTIONAL ANALYSIS PLAN

DD1391 SCOPE SUMMARY

FUNCTIONAL AREA

CALCULATED GROSS

AREA

2 SWS 3,800 SF

8 SES 5,334 SF

11 SWS 3,716 SF

460 OG - BID OPTION 2,518 SF

BUILDING SUPPORT 5,009 SF

BUILDING SUPPORT - OPTION 105 SF

CANOPY 368 SF

CIRCULATION 6,542 SF

CIRCULATION - OPTION 187 SF

CLASSROOM 3,844 SF

CORE NODE 586 SF

DEV & TESTING 557 SF

MEETING 2,081 SF

MEETING - OPTION 260 SF

OGI 1,977 SF

OGV 2,069 SF

OGX 3,705 SF

OSS 4,557 SF

OSS INSTRUCTORS 3,130 SF

PERSONNEL SUPPORT 3,504 SF

SST 5,404 SF

WEAPONS & TACTICS 1,528 SF

60,780 SF

AREA "A" AREA "B"

KEYPLAN - FIRST FLOOR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

*** CALCULATED PER UFC 3-101-01 AND AFM 32-1084. TOTAL

SOF CALCULATED GROSS AREA SHALL NOT EXCEED 61,515 SF.

GENERAL NOTES:

1. THESE DRAWINGS ARE CONCEPTUAL AND HAVE NOT BEEN FULLY

VETTED FOR CODE COMPLAINCE OR CONSTRUCTABILITY. THEY MAY NOT

COMMUNICATE FULL FACILITY REQUIREMENTS AS DESCRIBED IN THE

RFP, BUT IDENTIFY GENERAL SPACE SIZE, ADJACENCIES, AND CAPACITY

REQUIREMENTS. MINOR DEVIATIONS IN THE PLAN ARE ALLOWED FOR

CONSTRUCTABILITY AND CODE COMPLIANCE. SIGNIFICANT CHANGES IN

FLOOR PLAN LAYOUT SHALL BE APPROVED BY THE GOVERNMENT.

2. GRID LINES ARE FOR REFERENCE PURPOSES ONLY.

3. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING

ACCESSORY REQUIREMENTS PER SPACE. ANNOTATIONS ON PLAN ARE

NOT COMPREHENSIVE, BUT IDENTIFY PREFERRED MOUNTING LOCATIONS

FOR CERTAIN ITEMS. COORDINATE ALL FINAL MOUNTING LOCATIONS WITH

GOVERNMENT.

4. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE

LOCATION IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND

RFP REQUIREMENTS RELATING TO DESIGN AND CONSTRUCTION OF THIS

PORTION OF THE FACILITY. IF ONLY BASE BID IS AWARDED, PROVIDE

WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

5. MINIMUM UMBILICAL WIDTH AS INDICATED. UMBILICAL MAY BE

WIDENED BY CONTRACTOR UP TO 20'-0" TO ACCOMODATE BUILDING

INFRASTRUCTURE, PIPING, DUCTWORK, COMM.

DIESEL PIPELINE

ENTRANCE

GEN #1 INTAKE AIR ABOVE

DOOR - SIZE AS REQ'D

GEN #1 EXHAUST

AIR - SIZE AS REQ'D

GEN #2 EXHAUST

AIR - SIZE AS REQ'D

GEN #2 INTAKE AIR

ABOVE - SIZE AS REQ'D

GENERATOR

BUILDING

1368 SF*** 36

'-0

C

LR

4' -0

8'

-0 " C

LR

C

LR

4' -0

38'-0"

STRUCTURAL STOOP

12'-6" +/-

GENERATOR SET ON

6" HOUSEKEEPING PAD

GENERATOR SET ON

6" HOUSEKEEPING PAD

12' WIDE X 14' TALL

OVERHEAD COILING DOOR

12' WIDE X 14' TALL

OVERHEAD COILING DOOR

6" MIN CONC-FILLED STEEL

PIPE BOLLARDS - +/-4'-0" TALL -

TYP - PAINT SAFETY YELLOW

6" MIN CONC-FILLED STEEL

PIPE BOLLARDS - +/-4'-0" TALL -

TYP - PAINT SAFETY YELLOW

INSULATED PRECAST CONCRETE

WALL PANELS OR SIMILAR

CONSTRUCTION WITH LOW-SLOPE,

SINGLE-PLY MEMBRANE ROOF

DEVELOP ELEVATIONS OF

EMERGENCY POWER FACILITY TO

COMPLEMENT ADJACENT TOWER

STRUCTURE

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-110EPF

C O

N C

EP

T

EM

ER

G

EN

C Y

PO

W

E R F

A C

IL

IT

Y

FL

O

O R

P L A

N

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

1/8" = 1'-0"A-110EPF

1 CONCEPT EPF FLOOR PLAN

8'0 4' 16'32'8'0 16'

PLAN NORTH

*** AREA CALCULATED PER UFC 3-101-01 AND AFM 32-1084. DD1391 LIMIT FOR

THIS FACILITY IS 1,399 SF. FINAL FLOOR PLAN SHALL NOT EXCEED 1,399 SF.

GENERAL NOTES:

1. THESE DRAWINGS ARE CONCEPTUAL AND HAVE NOT BEEN FULLY VETTED

FOR CODE COMPLAINCE OR CONSTRUCTABILITY. THEY MAY NOT

COMMUNICATE FULL FACILITY REQUIREMENTS AS DESCRIBED IN THE RFP, BUT

IDENTIFY GENERAL SPACE SIZE, ADJACENCIES, AND CAPACITY

REQUIREMENTS. MINOR DEVIATIONS IN THE PLAN ARE ALLOWED FOR

CONSTRUCTABILITY AND CODE COMPLIANCE. SIGNIFICANT CHANGES IN

FLOOR PLAN LAYOUT SHALL BE APPROVED BY THE GOVERNMENT.

2. ANNOTATIONS ON PLAN ARE NOT COMPREHENSIVE, BUT IDENTIFY

PREFERRED MOUNTING LOCATIONS FOR CERTAIN ITEMS. COORDINATE ALL

FINAL MOUNTING LOCATIONS WITH GOVERNMENT.

MECHANICAL

UMBILICAL

S100

ELECTRICAL

HALL

COMMAND

CONFERENCE

ROOM (25 PN)

- BID OPTION

460 OSS

OPEN OFFICE

UPS

NIPR/SIPR

OGX OPEN

OFFICE

WELLNESS

11 SWS OPEN

OFFICE

11 SWS CMDR

OFFICE

135A

11 SWS

OFFICE

135B

OGX OFFICE

110B

460 OSS

OFFICE

116A

460 OSS

OFFICE

116B

460 OSS

OFFICE

116C

8 SES OPEN

OFFICE

2 SWS OPEN

OFFICE

216'-0" 34'-0" 20'-0"

0'

-0

NIPR/SIPR

TOILET

JANITORIAL

PAPER

RECYCLING

115A

OGX OFFICE

110A

PA

OGX

TRAINING

LAB

DEV &

TESTING

'-0

'-0

SE

E

N O

TE

'-0

'-0

11 SWS

OFFICE

HERITAGE

WALL

111A

250'-0" 20'-0"

ELECTRICAL

VESTIBULE

126A

ELECTRICAL

SECURE AREA BOUNDARY - SEE RFP

BOUNDARY LEGEND

CANOPY

CANOPY

1/ A-

1/ A-

25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 27'-0" 23'-0" 25'-0"

'-7

'-1 0"

'-7

CLASSROOM

SNOW

REMOVAL

EQUIP

STORAGE

101B

8 SES OFFICE

124D

8 SES OFFICE

124C

8 SES OFFICE

124B

8 SES OFFICE

124A

460 OSS

OFFICE

116D

460 OSS

CMDR

OFFICE

116E

LOBBY

HALL

11 SWS

OFFICE

135C

11 SWS

OFFICE

135D

SEE SITE PLAN FOR

SIDEWALK/ENTRY

PLAZA CONFIGURATION

30'-0" 140'-0" 46'-0" 34'-0"

WOM

INTERIOR

STOREFRONT -

SIMILAR TO

EXTERIOR

WOM

BD

BD

BB

VESTIBULE

STOREFRONT

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT

GLAZING @

CONFERENCE ROOM

BB/

EWC

PSPS

MBW MBW

TVM TVM

BB/

EWC

BB/

EWC

BB/

EWC

TVM

MBW

TVM

PS

TVM

TVM

SS

SS

SSSSSS

SS

TVM

PSTVM

BB

BB

BB

BB

TVM

BB

SEE SITE PLAN FOR

SIDEWALK/ENTRY PLAZA

CONFIGURATION

6" RECESSED SLAB

VESTIBULE

STOREFRONT

EXIT ONLY

EXIT ONLY

M

BW

TV

M

PS

OPEN STORAGE BOUNDARY - SEE RFP

FUTURE SAP BOUNDARY - SEE RFP

2 SWS CMDR

OFFICE

133E

2 SWS

OFFICE

133D

2 SWS

OFFICE

133C

2 SWS

OFFICE

133B

460 OG CMDR

OFFICE - BID

OPTION

129C

460 OG

OFFICE - BID

OPTION

129B

460 OG

OFFICE - BID

OPTION

129D

460 OG

OFFICE - BID

OPTION

129E

460 OG OPEN

OFFICE - BID

OPTION

BREAK AREA

W/ SINK

TVM

8 SES OFFICE

124E

8'-0"

2 SWS

OFFICE

133A

DUTY

OFFICER -

BID OPTION

126B

BREAK ROOM

CONF. RM.

(10 PN)

WOMEN'S

MEN'S

122 VM

VM

460 OG

OFFICE - BID

OPTION

129A

BUSINESS

CENTER

BUSINESS

CENTER

HERITAGE

WALL

132A

25'-0" 27'-0" 23'-0" 25'-0"

CLASSROOM

CORE NODE

25'-0" 25'-0" 25'-0" 25'-0" 25'-0" 25'-0"

SPARE

OFFICE

HERITAGE

WALL

101C

TS COMM

TOILET

TVM

BB

BUSINESS

CENTER

CONF. RM.

(10 PN) - BID

OPTION

'-0

'-6

VESTIBULE

DUTY

OFFICER

101A

COMMAND SUITE - BID OPTION - SEE NOTES

C O

M M

AN

D

S U

IT

E

- B

ID

O

PT

IO

N

SE

E N

O

TE

S

CORRIDOR

LOBBY

CORRIDOR

HALL - BID

OPTION

CORRIDOR

TRANSLUCENT GLAZING

@ MECH/ELEC YARD

WING/SCREEN WALL TO

MATCH ADJACENT BUILDING

WALL CONSTRUCTION/FINISH

SS

SS

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

TRANSLUCENT GLAZING @

INTERIOR WINDOWS - TYP

VM

ACCESS FLOORING SYSTEM BOUNDARY

BREAK AREA W/

SINK - SEE ROOM

DATA SHEETS

CASEWORK -

SEE RFP

CASEWORK -

SEE RFP

CASEWORK -

SEE RFP

CASEWORK -

SEE ROOM DATA

SHEETS CLEAR GLAZING @

INTERIOR WINDOWS -

DUTY OFFICER ONLY

CLEAR GLAZING @ INTERIOR

WINDOWS - DUTY OFFICER ONLY

BB

CASEWORK -

SEE ROOM DATA

SHEETS

RAMP AND RAILING AS

REQUIRED BY FINAL GRADING

SOLUTION - TYP

RAMP AND RAILING AS

REQUIRED BY FINAL GRADING

SOLUTION - TYP

MECHANICAL AND

ELECTRICAL EQUIPMENT

BEHIND SCREEN WALL - TYP

CUSTOM ARCHITECTURAL

SUNSHADES @ VISION

GLAZING - TYP

CUSTOM ARCHITECTURAL

SUNSHADES @ VISION

GLAZING - TYP

CUSTOM ARCHITECTURAL

SUNSHADES @ VISION

GLAZING - TYP

CUSTOM ARCHITECTURAL

SUNSHADES @ VISION

GLAZING - TYP

CUSTOM ARCHITECTURAL

SUNSHADES @ CURTAINWALL

CUSTOM ARCHITECTURAL

SUNSHADES @ VISION

GLAZING - TYP

CLAD DOOR WITH METAL PANELS

TO MATCH ADJACENT WALL US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-111

C O

N C

EP

T

FL

O

O R

P

LA

N

AR

EA

A

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

3/32" = 1'-0"A-111

1 CONCEPT FIRST FLOOR PLAN - AREA "A"

0 20'10'5'

PLAN NORTH

AREA "A"

KEYPLAN - FIRST FLOOR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

GENERAL NOTES:

1. THESE DRAWINGS ARE CONCEPTUAL AND HAVE NOT BEEN FULLY VETTED FOR CODE

COMPLAINCE OR CONSTRUCTABILITY. THEY MAY NOT COMMUNICATE FULL FACILITY

REQUIREMENTS AS DESCRIBED IN THE RFP, BUT IDENTIFY GENERAL SPACE SIZE,

ADJACENCIES, AND CAPACITY REQUIREMENTS. MINOR DEVIATIONS IN THE PLAN ARE ALLOWED

FOR CONSTRUCTABILITY AND CODE COMPLIANCE. SIGNIFICANT CHANGES IN FLOOR PLAN

LAYOUT SHALL BE APPROVED BY THE GOVERNMENT.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT, PERFORMANCE, AND BUILDING ACCESSORY

REQUIREMENTS PER SPACE. ANNOTATIONS ON PLAN ARE NOT COMPREHENSIVE, BUT

IDENTIFY PREFERRED MOUNTING LOCATIONS FOR CERTAIN ITEMS. COORDINATE ALL FINAL

MOUNTING LOCATIONS WITH GOVERNMENT.

3. RAMPS, WHERE REQUIRED, SHALL BE FULLY ABA ACCESSIBLE.

4. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE LOCATION

IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND RFP REQUIREMENTS RELATING

TO DESIGN AND CONSTRUCTION OF THIS PORTION OF THE FACILITY. IF ONLY BASE BID IS

AWARDED, PROVIDE WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

6. MINIMUM UMBILICAL WIDTH AS INDICATED. UMBILICAL MAY BE WIDENED BY CONTRACTOR UP

TO 20'-0" TO ACCOMODATE BUILDING INFRASTRUCTURE, PIPING, DUCTWORK, COMM. TOTAL

BUILDING SCOPE MAY NOT EXCEED DD1391 ALLOWABLE.

7. SEE A-112 FOR ROOM LEGEND.

BUILDING ACCESSORY NOTES:

BB BULLETIN (TACK) BOARD

BD BUILDING DIRECTORY

EWC ELECTRIC WATER COOLER(S)

PS PROJECTOR SCREEN(S)

RR REMOVEABLE RAILING PANEL

SS STRUCTURAL STOOP

TVM TELEVISION WALL MOUNT

VM VENDING MACHINE (N.I.C.)

WOM WALK OFF MAT

460 OG OGI

OPEN OFFICE

S124

WEAPONS/TACTICS

S108

CLASSROOM

S113

460 OSS

INSTRUCTORS

S109

MECHANICAL

S010

LARGE

CONFERENCE

S119

CLASSROOM

S115

CLASSROOM

S117

S/TS COMM

S118

SST SERVER

S122

TRAINING

CAB

S110-1

TRAINING

CAB

S110A-1

STANDARDIZED

SPACE

TRAINER

(SST)

S110

STANDARDIZED

SPACE

TRAINER

(SST)

S110A

AV

S119A

SMALL CONF

S121

W&T OFFICE

S108B

533 TS

OFFICE

S109B

533 TS

OFFICE

S109A

BATTLE LAB

S108C

ELECTRICAL

S106

OGI OFFICE

S124C

OGI OFFICE

S124B

OGI OFFICE

S124A

OGV OFFICE

S125C

OGV OFFICE

S125B

ELECTRICAL

S020

IST COMM

S123

W&T OFFICE

S108A

460 OG OGV

OPEN OFFICE

S125

OGV OFFICE

S125A

NIPR

S116

CLASSROOM/MISSION

PLANNING

S112

CLASSROOM/MISSION

PLANNING

S114

WOMEN

S103

BREAK/LOUNGE

S102

CORRIDOR

S107

CORRIDOR

S111

CORRIDOR

S120

STORAGE

S111A

STORAGE

S111B

MEN

S104

STORAGE/

JANITORIAL

S105

20'-0" 158'-0"

20'-0" 158'-0"

SCIF BOUNDARY - SEE RFP

OPEN STORAGE BOUNDARY - SEE RFP

BOUNDARY LEGEND

UMBILICAL

S100

1/ A-

1/ A-

0'

-0

131 SF

BUSINESS

CENTER

S125D

VERTICAL-DROP

PARTITION

26'-0" 25'-0" 26'-0" 22'-0" 27'-0" 26'-0" 6'-0"

'-0

'-0

'-0

6'-0"

WOM

EXIT ONLY

4'-0" X 7'-0" DOOR - EXIT ONLY

SS

SS

SS

SSSS SS

BB

BB

BB

BB

BB

BB

BB

BD BB

MOVEABLE

PARTITION WALL

MOVEABLE

PARTITION WALL

O N

E- W

AY

G

LA

SS

VI

SI

O N

G

LA

ZI

N

G W

O N

E - W

AY

G

LA

SS

VI

SI

O N

G

LA

ZI

N

G W

TVM

MBW MBW

TVM

MBW

TVM TVM

MBW

MBW

TVM

TVM

TVM

PS

PS

PS

PS

PS

PS

PS

TVM

TVM

TVM

TVM

TVM

TVM

MBW

MBW

MBW

MBW

MBW

BUSINESS

CENTER

139D

FUTURE SAP BOUNDARY - SEE RFP

'-0

'-0

'-0

HALL

S101

ONE-WAY GLASS

VISION GLAZIN W/

ONE-WAY GLASS

VISION GLAZING W/

ACCESS FLOORING SYSTEM BOUNDARY - SEE NOTE

BB

ACCESS FLOORING

SYSTEM ON DEPRESSED

SLAB - SEE RFP

REQUIREMNETS

ACCESS FLOORING SYSTEM

ON DEPRESSED SLAB - SEE

RFP REQUIREMNETS

SEE SITE PLAN FOR

SIDEWALK

CONFIGURATION

BREAK AREA W/

SINK - SEE ROOM

DATA SHEETS

BUILT-IN HIGH

COUNTER

RAMP AND RAILING AS

REQUIRED BY FINAL GRADING

SOLUTION - TYP

RAMP AND RAILING AS

REQUIRED BY FINAL

GRADING SOLUTION - TYP

26'-0" 25'-0" 26'-0" 22'-0" 27'-0" 26'-0" 6'-0"

BB/

EWC

BUSINESS CENTER

CASEWORK - SEE

RFP

BUSINESS CENTER

CASEWORK - SEE

RFP

ACCESS FLOORING SYSTEM

ON DEPRESSED SLAB - SEE

RFP REQUIREMNETS

SE

E

N O

TE

'-0

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-112

C O

N C

EP

T

FL

O

O R

P

LA

N

AR

EA

B

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

3/32" = 1'-0"A-112

1 CONCEPT FIRST FLOOR PLAN - AREA "B"

ROOM LEGEND

MARK ROOM NAME NET AREA

133A 2 SWS OFFICE 111 SF

133B 2 SWS OFFICE 111 SF

133C 2 SWS OFFICE 111 SF

133D 2 SWS OFFICE 111 SF

133E 2 SWS CMDR OFFICE 144 SF

134 BUSINESS CENTER 128 SF

135 11 SWS OPEN OFFICE 2,947 SF

135A 11 SWS CMDR OFFICE 147 SF

135B 11 SWS OFFICE 111 SF

135C 11 SWS OFFICE 111 SF

135D 11 SWS OFFICE 111 SF

136 CONF. RM. (10 PN) 242 SF

137 11 SWS OFFICE 111 SF

138 BUSINESS CENTER 74 SF

139 SPARE OFFICE 113 SF

139D BUSINESS CENTER 54 SF

S010 MECHANICAL 442 SF

S020 ELECTRICAL 267 SF

S100 UMBILICAL 519 SF

S101 HALL 87 SF

S102 BREAK/LOUNGE 577 SF

S103 WOMEN 258 SF

S104 MEN 258 SF

S105 STORAGE/ JANITORIAL 118 SF

S106 ELECTRICAL 86 SF

S107 CORRIDOR 348 SF

S108 WEAPONS/TACTICS 825 SF

S108A W&T OFFICE 111 SF

S108B W&T OFFICE 111 SF

S108C BATTLE LAB 337 SF

S109 460 OSS INSTRUCTORS 2,679 SF

S109A 533 TS OFFICE 111 SF

S109B 533 TS OFFICE 111 SF

S110 STANDARDIZED SPACE

TRAINER (SST)

2,012 SF

S110-1 TRAINING CAB 274 SF

S110A STANDARDIZED SPACE

TRAINER (SST)

2,102 SF

S110A-1 TRAINING CAB 276 SF

S111 CORRIDOR 485 SF

S111A STORAGE 13 SF

S111B STORAGE 17 SF

S112 CLASSROOM/MISSION

PLANNING

401 SF

S113 CLASSROOM 419 SF

S114 CLASSROOM/MISSION

PLANNING

401 SF

S115 CLASSROOM 419 SF

S116 NIPR 143 SF

S117 CLASSROOM 738 SF

S118 S/TS COMM 235 SF

S119 LARGE CONFERENCE 1,224 SF

S119A AV 96 SF

S120 CORRIDOR 784 SF

S121 SMALL CONF 312 SF

S122 SST SERVER 386 SF

S123 IST COMM 85 SF

S124 460 OG OGI OPEN OFFICE 1,435 SF

S124A OGI OFFICE 111 SF

S124B OGI OFFICE 111 SF

S124C OGI OFFICE 111 SF

S125 460 OG OGV OPEN OFFICE 1,391 SF

S125A OGV OFFICE 111 SF

S125B OGV OFFICE 111 SF

S125C OGV OFFICE 111 SF

S125D BUSINESS CENTER 131 SF

ROOM LEGEND

MARK ROOM NAME NET AREA

010 SNOW REMOVAL EQUIP 75 SF

020 ELECTRICAL 288 SF

030 CORE NODE 294 SF

040 UPS 200 SF

050 MECHANICAL 1,548 SF

100 VESTIBULE 137 SF

101 LOBBY 786 SF

101A DUTY OFFICER 109 SF

101B STORAGE 74 SF

101C HERITAGE WALL 21 SF

102 TOILET 43 SF

103 CLASSROOM 462 SF

104 TOILET 43 SF

105 CLASSROOM 463 SF

106 HALL 248 SF

107 TS COMM 97 SF

108 NIPR/SIPR 266 SF

109 PA 80 SF

110 OGX OPEN OFFICE 2,925 SF

110A OGX OFFICE 111 SF

110B OGX OFFICE 111 SF

111 CORRIDOR 946 SF

111A HERITAGE WALL 19 SF

112 OGX TRAINING LAB 302 SF

113 DEV & TESTING 522 SF

114 ELECTRICAL 100 SF

115 BREAK ROOM 674 SF

115A PAPER RECYCLING 129 SF

116 460 OSS OPEN OFFICE 3,751 SF

116A 460 OSS OFFICE 111 SF

116B 460 OSS OFFICE 111 SF

116C 460 OSS OFFICE 111 SF

116D 460 OSS OFFICE 111 SF

116E 460 OSS CMDR OFFICE 144 SF

117 BUSINESS CENTER 128 SF

118 HALL 221 SF

119 WOMEN'S 405 SF

120 WELLNESS 77 SF

121 JANITORIAL 57 SF

122 MEN'S 524 SF

123 ELECTRICAL 76 SF

124 8 SES OPEN OFFICE 4,502 SF

124A 8 SES OFFICE 111 SF

124B 8 SES OFFICE 111 SF

124C 8 SES OFFICE 111 SF

124D 8 SES OFFICE 111 SF

124E 8 SES OFFICE 111 SF

125 NIPR/SIPR 260 SF

126 LOBBY 315 SF

126A VESTIBULE 216 SF

126B DUTY OFFICER - BID OPTION 108 SF

127 HALL - BID OPTION 231 SF

128 CONF. RM. (10 PN) - BID OPTION 242 SF

129 460 OG OPEN OFFICE - BID

OPTION

1,024 SF

129A 460 OG OFFICE - BID OPTION 145 SF

129B 460 OG OFFICE - BID OPTION 145 SF

129C 460 OG CMDR OFFICE - BID

OPTION

226 SF

129D 460 OG OFFICE - BID OPTION 145 SF

129E 460 OG OFFICE - BID OPTION 145 SF

130 COMMAND CONFERENCE ROOM

(25 PN) - BID OPTION

509 SF

131 CORRIDOR 156 SF

132 CORRIDOR 787 SF

132A HERITAGE WALL 19 SF

133 2 SWS OPEN OFFICE 2,949 SF

0 20'10'5'

PLAN NORTH

AREA "B"

KEYPLAN - FIRST FLOOR

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

BUILDING ACCESSORY NOTES:

BB BULLETIN (TACK) BOARD

BD BUILDING DIRECTORY

EWC ELECTRIC WATER COOLER(S)

PS PROJECTOR SCREEN(S)

RR REMOVEABLE RAILING PANEL

SS STRUCTURAL STOOP

TVM TELEVISION WALL MOUNT

VM VENDING MACHINE (N.I.C.)

WOM WALK OFF MAT

GENERAL NOTES:

1. THESE DRAWINGS ARE CONCEPTUAL AND HAVE NOT BEEN FULLY VETTED FOR CODE

COMPLAINCE OR CONSTRUCTABILITY. THEY MAY NOT COMMUNICATE FULL FACILITY

REQUIREMENTS AS DESCRIBED IN THE RFP, BUT IDENTIFY GENERAL SPACE SIZE,

ADJACENCIES, AND CAPACITY REQUIREMENTS. MINOR DEVIATIONS IN THE PLAN ARE ALLOWED

FOR CONSTRUCTABILITY AND CODE COMPLIANCE. SIGNIFICANT CHANGES IN FLOOR PLAN

LAYOUT SHALL BE APPROVED BY THE GOVERNMENT.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT, PERFORMANCE, AND BUILDING ACCESSORY

REQUIREMENTS PER SPACE. ANNOTATIONS ON PLAN ARE NOT COMPREHENSIVE, BUT IDENTIFY

PREFERRED MOUNTING LOCATIONS FOR CERTAIN ITEMS. COORDINATE ALL FINAL MOUNTING

LOCATIONS WITH GOVERNMENT.

3. RAMPS, WHERE REQUIRED, SHALL BE FULLY ABA ACCESSIBLE.

4. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE LOCATION

IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND RFP REQUIREMENTS RELATING TO

DESIGN AND CONSTRUCTION OF THIS PORTION OF THE FACILITY. IF ONLY BASE BID IS

AWARDED, PROVIDE WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

6. MINIMUM UMBILICAL WIDTH AS INDICATED. UMBILICAL MAY BE WIDENED BY CONTRACTOR UP

TO 20'-0" TO ACCOMODATE BUILDING INFRASTRUCTURE, PIPING, DUCTWORK, COMM. TOTAL

BUILDING SCOPE MAY NOT EXCEED DD1391 ALLOWABLE.

***ACCESS FLOORING SYSTEM BID OPTION - THE BASE BID FOR THIS PROJECT INCLUDES SCOPE FOR INSTALLATION OF A RAISED ACCESS FLOORING SYSTEM WITHIN THE PERIMETER SHOWN ON THESE PLANS. THIS PROJECT CONTAINS A BID OPTION TO DESIGN AND CONSTRUCT RAISED ACCESS FLOORING IN REMAINING AREAS OF THE SECURE AREA AS INDICATED IN THE ROOM DATA SHEETS, TOTALLING APPROXIMATELY 1,400 SM. IF THE BID OPTION IS AWARDED, THE CONTRACTOR SHALL DESIGN AND CONSTRUCT A RAISED ACCESS FLOORING SYSTEM THAT IS IDENTICAL THE THE ONE PROVIDED IN THE BASE BID, SEE RFP FOR REQUIRMENTS. FLOOR

FINISHES IN THOSE SPACES SHALL REMAIN THE SAME AS SPECIFIED IN THE BASE BID.

OPEN STORAGE SECURE AREA

270'-0" 178'-0"

'-0

'-0

'-0

0'

-0

34'-0" 20'-0" 20'-0"

'-0

'-0

'-0

'-0

37'-8" 212'-4" 40'-0" 158'-0"

6'-0"

'-6

'-0

'-6

BID OPTION - SEE NOTES

COMMAND SUITE

SE

E

N O

TE

S

C O

M M

AN

D

S U

IT

E

BI

D

O

PT

IO

N DAYLIGHTING FEATURES TO MEET RFP

DAYLIGHTING REQUIREMENTS - SEE RFP

FOR SPACE DAYLIGHTING REQUIREMENTS

AND ALLOWABLE FEATURES

SEE RFP FOR ROOF DRAINAGE

REQUIREMENTS AND ALLOWABLE

FEATURES AND STRATEGIES - TYP

DAYLIGHTING FEATURES TO MEET RFP

DAYLIGHTING REQUIREMENTS - SEE RFP

FOR SPACE DAYLIGHTING REQUIREMENTS

AND ALLOWABLE FEATURES

SEE RFP FOR ROOF DRAINAGE

REQUIREMENTS AND ALLOWABLE

FEATURES AND STRATEGIES - TYP

SEE RFP FOR ROOF DRAINAGE

REQUIREMENTS AND ALLOWABLE

FEATURES AND STRATEGIES - TYP

SEE RFP FOR ROOF DRAINAGE

REQUIREMENTS AND ALLOWABLE

FEATURES AND STRATEGIES - TYP

DAYLIGHTING FEATURES TO MEET RFP

DAYLIGHTING REQUIREMENTS - SEE RFP

FOR SPACE DAYLIGHTING REQUIREMENTS

AND ALLOWABLE FEATURESROOF ACCESS VIA LADDER

FROM MECHANICAL ROOM

COMM EQUIPMENT

LAYDOWN

ENTRANCE CANOPY

SINGLE-PLY

MEMBRANE

ROOF - TYP

SINGLE-PLY

MEMBRANE

ROOF - TYP

SINGLE-PLY

MEMBRANE

ROOF - TYP

SINGLE-PLY

MEMBRANE

ROOF - TYP

SINGLE-PLY

MEMBRANE

ROOF - TYP

ENTRANCE CANOPY

ROOF-MOUNTED

EQUIPMENT OVER UTILITY

SPACES ONLY - IF REQ'D

ROOF-MOUNTED

EQUIPMENT OVER UTILITY

SPACES ONLY - IF REQ'D

PARAPET WALL TO SCREEN

MECHANICAL EQUIPMENT FROM

ROAD - SEE ELEVATIONS

PARAPET WALL TO SCREEN

MECHANICAL EQUIPMENT FROM

ROAD - SEE ELEVATIONS

N O

TE

SE

E

1"

1' -0

1/ 2"

1'

-0

1/ 2"

1'

-0

1/ 2"

1'

-0

1/ 2"

1'

-0

1/ 2"

1'

-0

1/ 2"

1'

-0

1/ 2"

1'

-0

447'-11"

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-120

C O

N C

EP

T

R O

O F

PL

AN

C

O M

PO

S I

TE

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/64" = 1'-0"A-120

1 CONCEPT ROOF PLAN - COMPOSITE

0 10' 20' 40'

PLAN NORTH

AREA "A" AREA "B"

KEYPLAN - ROOFGENERAL NOTES:

1. SEE ROOM DATA SHEETS, ATTACHED TO THE RFP FOR SPACE-BY-SPACE

FINISH, EQUIPMENT, AND PERFORMANCE REQUIREMENTS.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING ACCESSORY

REQUIREMENTS PER SPACE. ANNOTATIONS ON PLAN ARE NOT COMPREHENSIVE,

BUT IDENTIFY PREFERRED MOUNTING LOCATIONS FOR CERTAIN ITEMS.

COORDINATE ALL FINAL MOUNTING LOCATIONS WITH GOVERNMENT.

3. SEE AREA PLANS FOR ADDITIONAL NOTES AND DIMENSIONS.

4. ROOF LAYOUT IS A CONCEPT LAYOUT, DOR MAY ALTER AS REQUIRED FOR

ENGINEERING PURPOSES, ECONOMY, AND SIMPLICITY AS LONG AS AESTHETIC

CONCEPT IS PRESERVED. ANY SIGNIFICANT DEVIATIONS SHALL BE SUBMITTED

TO THE GOVERNMENT FOR APPROVAL.

5. MINIMUM UMBILICAL WIDTH AS INDICATED. UMBILICAL MAY BE WIDENED BY

CONTRACTOR UP TO 20'-0" TO ACCOMODATE BUILDING INFRASTRUCTURE,

PIPING, DUCTWORK, COMM. TOTAL BUILDING SCOPE MAY NOT EXCEED DD1391

ALLOWABLE.

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3" 1/

A-

1/

A-

BID OPTION

COMMAND SUITE

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

LOOK ANGLE OF CONTROLLING RADAR ARRAY

COMMAND SUITE BID OPTION

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

LOOK ANGLE OF CONTROLLING RADAR ARRAY

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

2/ A-

2/ A-

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-201

C O

N C

EP

T

BU

I L

D

IN

G E

LE

V A

TI

O

N S

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/64" = 1'-0"A-201

1 PLAN NORTH COMPOSITE ELEVATION

3/64" = 1'-0"A-201

2 PLAN WEST COMPOSITE ELEVATION

3/64" = 1'-0"A-201

3 PLAN EAST COMPOSITE ELEVATION

3/64" = 1'-0"A-201

4 PLAN SOUTH COMPOSITE ELEVATION

0 10' 20' 40'

AREA "A" AREA "B"

KEYPLAN -GENERAL NOTES:

1. SEE ROOM DATA SHEETS, ATTACHED TO THE RFP FOR SPACE-BY-

SPACE FINISH, EQUIPMENT, AND PERFORMANCE REQUIREMENTS.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING

ACCESSORY REQUIREMENTS PER SPACE. COORDINATE ALL FINAL

MOUNTING LOCATIONS WITH GOVERNMENT.

3. SEE AREA PLANS FOR ADDITIONAL NOTES AND DIMENSIONS.

4. ELEVATIONS ARE CONCEPT ELEVATIONS, DOR MAY ALTER AS

REQUIRED FOR ENGINEERING PURPOSES, ECONOMY, AND SIMPLICITY AS

LONG AS AESTHETIC CONCEPT IS PRESERVED. ANY SIGNIFICANT

DEVIATIONS SHALL BE SUBMITTED TO THE GOVERNMENT FOR APPROVAL.

5. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE

LOCATION IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND

RFP REQUIREMENTS RELATING TO DESIGN AND CONSTRUCTION OF THIS

PORTION OF THE FACILITY. IF ONLY BASE BID IS AWARDED, PROVIDE

WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

LOOK ANGLE OF CONTROLLING RADAR ARRAY

PCP

VIZWP

ECB

ZC

R/S

ZC

PCP

ECB

CANOPY -

BEYOND

SD

SD

R/S

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

LOOK ANGLE OF CONTROLLING RADAR ARRAY

VIZWP

ECB WF/

FASH

HCZWPZC ZC

CW

CANOPY -

BEYOND

FASH

CW/GT1 CW/GT2

VIZWP

FASH

CANOPY WF/

FASH

ECB

COMMAND SUITE BID OPTION - SEE NOTES

CW/GT3

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-210

EN

LA

R G

ED

C

O N

C E P

T

BU

IL

D

IN

G

EL

E V

AT

IO

N S

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/32" = 1'-0"A-210

1 PLAN EAST ENLARGED ELEVATION

3/32" = 1'-0"A-210

2 PLAN WEST ENLARGED ELEVATION

0 20'10'5'

AREA "A" AREA "B"

KEYPLAN -

GENERAL NOTES:

1. SEE ROOM DATA SHEETS, ATTACHED TO THE RFP FOR SPACE-BY-

SPACE FINISH, EQUIPMENT, AND PERFORMANCE REQUIREMENTS.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING

ACCESSORY REQUIREMENTS PER SPACE. COORDINATE ALL FINAL

MOUNTING LOCATIONS WITH GOVERNMENT.

3. SEE AREA PLANS FOR ADDITIONAL NOTES AND DIMENSIONS.

4. ELEVATIONS ARE CONCEPT ELEVATIONS, DOR MAY ALTER AS

REQUIRED FOR ENGINEERING PURPOSES, ECONOMY, AND SIMPLICITY AS

LONG AS AESTHETIC CONCEPT IS PRESERVED. ANY SIGNIFICANT

DEVIATIONS SHALL BE SUBMITTED TO THE GOVERNMENT FOR

APPROVAL.

5. EXTERIOR LIGHTING, DOOR HARDWARE, AND OTHER BUILDING

APPURTENANCES SHALL BE INTEGRATED INTO THE FINAL BUILDING

AESTHETIC. SELECT ITEMS THAT REINFORCE THE STYLING DESCRIBED IN

THE RFP AND APPLY THEM IN A MANNER THAT IS CONSISTENT WITH THAT

CONCEPT.

6. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE

LOCATION IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND

RFP REQUIREMENTS RELATING TO DESIGN AND CONSTRUCTION OF THIS

PORTION OF THE FACILITY. IF ONLY BASE BID IS AWARDED, PROVIDE

WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

ELEVATION NOTES:

CW ALUMINUM CURTAINWALL - TYP

ECB EXPOSED CONC BASE - TYP

FASH FIXED ALUMINUM SUNSHADE - TYP - SEE RFP REQ'S

HCZWP HORIZONTAL CORRUGATED ZINC WALL PANEL SYSTEM - TYP

GT1 GLAZING - TINTED/TRANSPARENT - SEE RFP REQ'S

GT2 GLAZING - OPAQUE/TRANSLUSCENT/FRITTED - SEE RFP REQ'S

GT3 GLAZING - OPAQUE/SPANDREL - SEE RFP REQ'S

PCP PRECAST CONCRETE PANEL W/ TEXTURE - SEE RFP REQ'S

R/S RAMP/STAIR W/ GUARD/HANDRAIL - AS REQ'D - SEE RFP REQ'S

SD STEEL DOOR

VIZWP VERTICAL INTERLOCKING ZINC WALL PANEL SYSTEM - TYP

WF WINDOW - FIXED - TYP

ZC ZINC COPING - TYP

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

1/ A-

COMMAND SUITE BID OPTION - SEE NOTES

VIZWP

ECB WF

HCZWP

ZC

R/S

ZC

CW

CANOPY -

BEYOND

CW/GT1 CW/GT2

VIZWP

FASH

CANOPY WF/

FASH

ECB

CW/GT3 ZC

ZINC PANEL

CLAD DOOR

CW/GT1

ZC ZC

HCZWP

CW/GT2CW/GT1

CW/GT3

FASH

CW/GT3

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

2/ A-

VIZWP

ECB

HCZWP

ZC

R/S

ZC

CW

CANOPY -

BEYOND

CW/GT1

CW/GT1

VIZWP

FASH

WF/

FASH

ECB

ZC

CW/GT2

ZCZC

HCZWP

CW/GT2 CW/GT1WF/

FASH SCREEN WALL TO

MATCH BUILDING

CLADDING

FASH FASH

CW/GT3 CW/GT3

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-211

C O

N C

EP

T

B U

IL

D

IN

G E

L E

VA

TI

O

N S

- A R

EA

"A

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/32" = 1'-0"A-211

1 PLAN NORTH ENLARGED ELEVATION - AREA "A"

3/32" = 1'-0"A-211

2 PLAN SOUTH ENLARGED ELEVATION - AREA "A"

0 20'10'5'

AREA "A"

KEYPLAN -

GENERAL NOTES:

1. SEE ROOM DATA SHEETS, ATTACHED TO THE RFP FOR SPACE-BY-

SPACE FINISH, EQUIPMENT, AND PERFORMANCE REQUIREMENTS.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING

ACCESSORY REQUIREMENTS PER SPACE. COORDINATE ALL FINAL

MOUNTING LOCATIONS WITH GOVERNMENT.

3. SEE AREA PLANS FOR ADDITIONAL NOTES AND DIMENSIONS.

4. ELEVATIONS ARE CONCEPT ELEVATIONS, DOR MAY ALTER AS

REQUIRED FOR ENGINEERING PURPOSES, ECONOMY, AND SIMPLICITY AS

LONG AS AESTHETIC CONCEPT IS PRESERVED. ANY SIGNIFICANT

DEVIATIONS SHALL BE SUBMITTED TO THE GOVERNMENT FOR

APPROVAL.

5. EXTERIOR LIGHTING, DOOR HARDWARE, AND OTHER BUILDING

APPURTENANCES SHALL BE INTEGRATED INTO THE FINAL BUILDING

AESTHETIC. SELECT ITEMS THAT REINFORCE THE STYLING DESCRIBED IN

THE RFP AND APPLY THEM IN A MANNER THAT IS CONSISTENT WITH THAT

CONCEPT.

6. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE

LOCATION IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND

RFP REQUIREMENTS RELATING TO DESIGN AND CONSTRUCTION OF THIS

PORTION OF THE FACILITY. IF ONLY BASE BID IS AWARDED, PROVIDE

WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

ELEVATION NOTES:

CW ALUMINUM CURTAINWALL - TYP

ECB EXPOSED CONC BASE - TYP

FASH FIXED ALUMINUM SUNSHADE - TYP - SEE RFP REQ'S

HCZWP HORIZONTAL CORRUGATED ZINC WALL PANEL SYSTEM - TYP

GT1 GLAZING - TINTED/TRANSPARENT - SEE RFP REQ'S

GT2 GLAZING - OPAQUE/TRANSLUSCENT/FRITTED - SEE RFP REQ'S

GT3 GLAZING - OPAQUE/SPANDREL - SEE RFP REQ'S

PCP PRECAST CONCRETE PANEL W/ TEXTURE - SEE RFP REQ'S

R/S RAMP/STAIR W/ GUARD/HANDRAIL - AS REQ'D - SEE RFP REQ'S

SD STEEL DOOR

VIZWP VERTICAL INTERLOCKING ZINC WALL PANEL SYSTEM - TYP

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

1/ A-

HCZWP

CW/GT1

PCP

ECB

HCZWP

ZC

ZC

ECB

FINISH FLOOR

100' - 0"

TO LOW PARAPET

122' - 0"

TO HIGH PARAPET

128' - 3"

2/ A-

HCZWP

CW/GT1

ZC

PCP

ECB

SDZC PCP

ECB

SD

R/S

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-212

C O

N C

EP

T

B U

IL

D

IN

G E

L E

VA

TI

O

N S

- A R

EA

"B

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/32" = 1'-0"A-212

1 PLAN NORTH ENLARGED ELEVATION - AREA "B"

3/32" = 1'-0"A-212

2 PLAN SOUTH ENLARGED ELEVATION - AREA "B"

0 20'10'5'

AREA "B"

KEYPLAN -

GENERAL NOTES:

1. SEE ROOM DATA SHEETS, ATTACHED TO THE RFP FOR SPACE-BY-

SPACE FINISH, EQUIPMENT, AND PERFORMANCE REQUIREMENTS.

2. SEE ROOM DATA SHEETS FOR ALL EQUIPMENT AND BUILDING

ACCESSORY REQUIREMENTS PER SPACE. COORDINATE ALL FINAL

MOUNTING LOCATIONS WITH GOVERNMENT.

3. SEE AREA PLANS FOR ADDITIONAL NOTES AND DIMENSIONS.

4. ELEVATIONS ARE CONCEPT ELEVATIONS, DOR MAY ALTER AS

REQUIRED FOR ENGINEERING PURPOSES, ECONOMY, AND SIMPLICITY AS

LONG AS AESTHETIC CONCEPT IS PRESERVED. ANY SIGNIFICANT

DEVIATIONS SHALL BE SUBMITTED TO THE GOVERNMENT FOR

APPROVAL.

5. EXTERIOR LIGHTING, DOOR HARDWARE, AND OTHER BUILDING

APPURTENANCES SHALL BE INTEGRATED INTO THE FINAL BUILDING

AESTHETIC. SELECT ITEMS THAT REINFORCE THE STYLING DESCRIBED IN

THE RFP AND APPLY THEM IN A MANNER THAT IS CONSISTENT WITH THAT

CONCEPT.

6. THIS PROJECT CONTAINS A BID OPTION FOR A COMMAND SUITE - IN THE

LOCATION IDENTIFIED IN THE DRAWINGS. SEE THE BID SCHEDULE AND

RFP REQUIREMENTS RELATING TO DESIGN AND CONSTRUCTION OF THIS

PORTION OF THE FACILITY. IF ONLY BASE BID IS AWARDED, PROVIDE

WINDOW AND CURTAINWALL ON BASE BID PERIMETER SIMILAR TO THE

CONFIGURATION SHOWN ON THE OPTIONED WALL AND ELEVATIONS.

ELEVATION NOTES:

CW ALUMINUM CURTAINWALL - TYP

ECB EXPOSED CONC BASE - TYP

FASH FIXED ALUMINUM SUNSHADE - TYP - SEE RFP REQ'S

HCZWP HORIZONTAL CORRUGATED ZINC WALL PANEL SYSTEM - TYP

GT1 GLAZING - TINTED/TRANSPARENT - SEE RFP REQ'S

GT2 GLAZING - OPAQUE/TRANSLUSCENT/FRITTED - SEE RFP REQ'S

GT3 GLAZING - OPAQUE/SPANDREL - SEE RFP REQ'S

PCP PRECAST CONCRETE PANEL W/ TEXTURE - SEE RFP REQ'S

R/S RAMP/STAIR W/ GUARD/HANDRAIL - AS REQ'D - SEE RFP REQ'S

SD STEEL DOOR

VIZWP VERTICAL INTERLOCKING ZINC WALL PANEL SYSTEM - TYP

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-900

C O

N C

EP

T

PE

R

S P

EC

T I

VE

S

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A-900

1 NORTHWEST PERSPECTIVE

NOTE:

BUILDING PERSPECTIVES ARE PROVIDED FOR

VISUALIZATION PURPOSES ONLY. IMAGES MAY

INCLUDE BID OPTIONS OR MAY REMOVE SOME

ITEMS FOR CLARITY. SEE ALL DESIGN DRAWINGS

AND RFP FOR THE FULL SCOPE OF WORK.

A-900

5 SOUTHEAST PERSPECTIVE

A-900

2 NORTHEAST ENTRY PERSPECTIVE

A-900

3 NORTHWEST ENTRY PERSPECTIVE

A-900

4 SOUTHWEST SECONDARY ENTRY PERPECTIVE

Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

A-901

C O

N C

EP

T

PE

R

S P

EC

T I

VE

S

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

A.

T

EM

EY

ER

A.

T

EM

EY

ER

B.

G

O R

U P

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

A-901

2 SOUTHWEST BIRDSEYE PERSPECTIVE

NOTE:

BUILDING PERSPECTIVES ARE PROVIDED FOR

VISUALIZATION PURPOSES ONLY. IMAGES MAY

INCLUDE BID OPTIONS OR MAY REMOVE SOME

ITEMS FOR CLARITY. SEE ALL DESIGN DRAWINGS

AND RFP FOR THE FULL SCOPE OF WORK.

A-901

1 NORTHEAST BIRDSEYE PERSPECTIVE

Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

I-110

FI

R

ST

F

L O O

R F

U R

N

IT

U R

E

PL

AN

C O

M

PO

S I

TE

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

K.

R

IE

G

E

K.

R

IE

G

E

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

32'8'0 16'

PLAN NORTH

AREA "A" AREA "B"

KEYPLAN - FIRST FLOOR

3/64" = 1'-0"I-110

1 FIRST FLOOR FURNITURE PLAN - COMPOSITE

LOBBY

MECHANICAL

UMBILICAL

S100

8 SES OFFICE

124E

460 OSS

OFFICE

116A

ELECTRICAL

HALL

MEN'S

BREAK ROOM

CONF. RM.

(10 PN)

CONF. RM.

(10 PN) - BID

OPTION

COMMAND

CONFERENCE

ROOM (25 PN)

- BID OPTION

460 OSS

OFFICE

116C

460 OSS

OFFICE

116B

460 OSS

OPEN OFFICE

UPS

NIPR/SIPR

OGX OPEN

OFFICE

WELLNESS

11 SWS OPEN

OFFICE

11 SWS CMDR

OFFICE

135A

11 SWS

OFFICE

135B

OGX OFFICE

110B

8 SES OPEN

OFFICE

2 SWS OPEN

OFFICE

NIPR/SIPR

TOILET

JANITORIAL

PAPER

RECYCLING

115A

OGX OFFICE

110A

PA

OGX

TRAINING

LAB

DEV &

TESTING

11 SWS

OFFICE

HERITAGE

WALL

111A

ELECTRICAL

VESTIBULE

126A

ELECTRICAL

8 SES OFFICE

124D

8 SES OFFICE

124C

8 SES OFFICE

124B

8 SES OFFICE

124A

460 OSS

OFFICE

116D

460 OSS

CMDR

OFFICE

116E

CLASSROOM

STORAGE

101B

HA

LL

11 SWS

OFFICE

135C

11 SWS

OFFICE

135D

SNOW

REMOVAL

EQUIP

0102 SWS CMDR

OFFICE

133E

2 SWS

OFFICE

133D

2 SWS

OFFICE

133C

2 SWS

OFFICE

133B

460 OG CMDR

OFFICE - BID

OPTION

129C

460 OG

OFFICE - BID

OPTION

129B

460 OG

OFFICE - BID

OPTION

129D

460 OG

OFFICE - BID

OPTION

129E

460 OG OPEN

OFFICE - BID

OPTION

2 SWS

OFFICE

133A

E6 E6 E6 E6 E6 E6 E6 E6 E6

E15

T6 T7

S4 T6

T6

T6

S4S4 T6

S4S4 T6

S4S4 T6

S4S4 T6

S4S4 T6

S4S4 T6

T7

S4 S4 T6

S4 S4 T6

S4 S4 T6

S4 S4 T6

S4 S4 T6

S4 S4 T6

T7

S2

S2

S2

S2

S2

S2

S2

S2

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2

S2 S1

S1

S1

S4 S4

S4S4S4S4

S4

S4

T7 S4 S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S4 S4

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

E8

E5

E5

E5E5

E8

S2

S2 S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1 S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1

S1

T1

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S2

S2

S1

S1

S1

S2

S2

S2

S2

S2

S2 S1

S1

S1

S2

S2

S1

E10 E6

E6

E6

E6

E6

E4

S1S1

S1S1

S1S1

S1S1

S1S1

T8

S7

S7

T8

S7

S7

S2

S2 S1

S2

S2 S1

S1 S2

S2

E5E5

E5E5

E5E5

E5E5

E5E5

E5E5

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2

W2

W2

W2

W2

W2 W2

W2 W2

W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W2 W2

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W4W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W4

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W4W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

W1W1

E9

E7

E7

D2

D2

D2

D2

D2

D2

D1

D2

D2

D2

D2

D2

D1

D2

D2

D2

D1

D2

D2

D2

E1

CLASSROOM

SPARE

OFFICE

DUTY

OFFICER -

BID OPTION

126B

WOMEN'S

460 OG

OFFICE - BID

OPTION

129A

BUSINESS

CENTER

BUSINESS

CENTER

HERITAGE

WALL

132A

CORE NODE

HERITAGE

WALL

101C

TS COMM

107 TOILET

E6

E6

E4A

E2

E3

E4A

E4A

E4A E4A E3E3

E3

E7

E7E7

E7

E14

E1

E1

E1

E1

S2S2

S1D2

S2 S2

S1 D2

E1

E6

E6

E4A

E2

E1

E6 E6

E4A E2

E13

E6E6

E4A E2

E13

S2

S2 S1

D2

S1

S1

S1

S1

S1

S1

W2 W2

W2 W2

W2 W2

M1

M1

S7

T8

S7

S7

T8

S7

CORRIDOR

HALL - BID

OPTION

CORRIDOR

BUSINESS

CENTER

VESTIBULE

DUTY

OFFICER

101A

LOBBY

CORRIDOR

F1 F1

F2 F2

S2 T8 S2

S2T8S2 S2T8S2

S1

S1

T8S8M3

M3

T1

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3 S5 T2

S5

S5 T2 S5

S5 T2 S5

S5 S5

T2 S5

S5

S5 T2 S5

S5 T2 S5

S5 T2 S5

S5 S5

T2 S5

S5

S5 T2 S5

S5 T2 S5

S5 T2 S5

S5 S5

T2 S5

S5

E1

A3

A3

A3

A2 A2

A2

M2

M2

S1S1

S1S1 W1W1

W1 W4 S1S1

S1S1 W1W1

W1W4

FURNITURE LEGEND:

A1 SMALL WASTE RECEPTACLE

A2 LARGE WASTE RECEPTACLE

A3 RECYCLING RECEPTACLE

D1 U-SHAPED DESK, COMMANDER

D2 U-SHAPED DESK

E1 EX DESK, COMMANDER

E2 EX DESK

E3 EX WORKSTATION, RECEPTION

E4 EX DESK CHAIR, COMMANDER

E4A EX DESK CHAIR

E5 EX CONFERENCE CHAIR

E6 EX GUEST CHAIR

E7 EX LOUNGE CHAIR

E8 EX CONFERENCE TABLE

E9 EX SIDE TABLE

E10 EX MEETING TABLE

E11 EX COFFEE TABLE

E12 EX LATERAL FILE

E13 EX WARDROBE

E14 EX CREDENZA

E15 EX LECTERN

F1 STORAGE CABINET

F2 CREDENZA, 48"W

F3 CREDENZA, 60"W

M1 MICROWAVE

M2 REFRIGERATOR, FULL SIZE

M3 REFRIGERATOR, COMPACT

M4 LECTERN

S1 DESK CHAIR

S2 GUEST CHAIR

S3 CONFERENCE CHAIR

S4 TRAINING CHAIR

S5 BREAK CHAIR

S6 STOOL

S7 LOUNGE CHAIR

S8 RECLINER

T1 CONFERENCE TABLE, 120"W

T2 BREAK TABLE, 30"W

T3 CONFERENCE TABLE, 84"W

T4 CONFERENCE TABLE, 144"W

T5 BREAK TABLE, 36"W

T6 CLASSROOM TABLE

T7 CLASSROOM TABLE, SMALL

T8 SIDE TABLE

W1 WORKSTATION

W2 WORKSTATION, HOTELING

W3 WORKSTATION, TRAINING

W4 WORKSTATION, ADMINISTRATIVE

NOTES:

1. FURNITURE LAYOUT IS CONCEPTUAL AND MAY NOT COMMUNICATE

ALL REQUIREMETNS AS DESCRIBED IN THE RFP. SIGNIFICANT

CHANGES IN FURNITURE LAYOUT SHALL BE APPROVED BY THE

GOVERNMENT.

2. PROCUREMENT AND INSTALLATION OF FF&E (EXCLUDING THE

COMMAND SUITE FF&E) IS A BID OPTION. PROCUREMENT AND

INSTALLATION OF COMMAND SUITE FF&E IS A SEPARATE BID OPTION.

SEE 01 81 00 FOR ADDITIONAL INFORMATION ON BID OPTIONS.

3. SEE ROOM DATA SHEETS AND FF&E FOR ADDITIONAL FURNITURE

REQUIREMENTS.

4. SEE APPENDIX L - FURNISHINGS, FIXTURES, & EUIPMENT (FF&E)

PACKAGE FOR LOCATION OF A1 SMALL WASTE RECEPTACLE.

5. PRINTERS AND VENDING MACHINES ARE NOT IN CONTRACT.

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

I-111

FI

R

ST

F

LO

O

R F

U R

N

IT

U R

E

PL

AN

A R

EA

A

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

K.

R

IE

G

E

K.

R

IE

G

E

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

3/32" = 1'-0"I-111

1 FIRST FLOOR FURNITURE PLAN - AREA A

0 20'10'5'

PLAN NORTH

AREA "A"

KEYPLAN - FIRST FLOOR

SMALL CONF

S121

CLASSROOM

S117

LARGE

CONFERENCE

S119

CL

AS

SR

O

O M

S1

460 OG OGI

OPEN OFFICE

S124

WEAPONS/TACTICS

S108

CL

AS

SR

O

O M

S1

460 OSS

INSTRUCTORS

S109

MECHANICAL

S010

STANDARDIZED

SPACE

TRAINER

(SST)

S110A

TRAINING

CAB

S110A-1

TRAINING

CAB

S110-1

STANDARDIZED

SPACE

TRAINER

(SST)

S110

S/TS COMM

S118

SST SERVER

S122

AV

S119A

W&T OFFICE

S108B

533 TS

OFFICE

S109B

533 TS

OFFICE

S109A

BATTLE LAB

S108C

ELECTRICAL

S106

OGV OFFICE

S125A

OGI OFFICE

S124C

OGI OFFICE

S124B

OGI OFFICE

S124A

OGV OFFICE

S125C

OGV OFFICE

S125B

460 OG OGV

OPEN OFFICE

S125

ELECTRICAL

S020

IST COMM

S123

W&T OFFICE

S108A

NIPR

S116

CL

AS

SR

O

O M

/M

IS

SI

O

N

PL

AN

NI

NG

S1

CL

AS

SR

O

O M

/M

IS

SI

O

N

PL

AN

NI

NG

S1

WOMEN

S103

MEN

S104

BREAK/LOUNGE

S102

CORRIDOR

S107

CORRIDOR

S111

CORRIDOR

S120

ST

O

RA

G

E S1

A

ST

O

RA

G

E S1

B

STORAGE/

JANITORIAL

S105

UMBILICAL

S100

BUSINESS

CENTER

S125D

BUSINESS

CENTER

139D

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4 S4 T6

S4 S4 T6

S4 S4 T6

S4 S4 T6

S4 S4

S4 S4 S4 S4

S4 S4

S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2S2

S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2 S2

S2 S2

S2

T4

T1 T1

T1

T1

T1

T1

M4

T1

W3

W3

W3

W3

W3

W3

W3

W3

W3 W3W3

W3 W3W3

F1

F1

F1

F1

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

T7

T5 S5

S5 S5

S5

T5 S5

S5 S5

S5

T3

S4

S4

S4

S4S4S4

S4S4S4

S1S1 S2

S2

S2

S2

S6

S6

S6

S6

S6

S6

S6

S6

S1

S1

S1

S2

S2

S2

S2

S2

S2

S1 S2

S2

S1 S2

S2

S1 S2

S2

T6

T6

T6

T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4

S4 T6

S4 S4 T6

S4 S4 T6

S4 S4

S4 S4 T6

T6

S3S3S3 S3

S3S3S3 S3

S3S3

S3

S4

S4T7

S1 S2

S2

S4

S4

S4

S4

S4 T6

T7 S4

T7 S4

T7 S4

S1

S1

S1

S1

S1

S1

S1

S1

S1 S1 S1

S1 S1 S1

S1

S1

S1

S1

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3

S3S3 S3

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1

S1S1

S1S1

S1

S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1

S1S1 S1S1 W1W1 W1W1

W1W1 W1W1

W1W1 W1W1

W1

W1W1

W1W1 W1

W1W1

W1W1 W1W1

W1W1 W1W1

W1W1

W1W1

W1

W1

W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

W1 W1

D2

D2

D2D2

D2

D2

D2 D2

D2

S1 S2

S2

D2

M1

HALL

S101

S2 S2 S2

F1

F1

F1

F1

S4 S4 T6

S4 S4 S4 S4 T6T6

F1

F3

T6

T6

T6

A3

A2

A2

A2

A2 A2

A2

A2

A2 A2

A2

M2

F2

W3

W3

W3

W3

W3

W3

W3

W3

W3W3 W3

W3W3 W3

S1

S1

S1

S1

S1

S1

S1

S1

S1S1S1

S1S1S1

FURNITURE LEGEND:

A1 SMALL WASTE RECEPTACLE

A2 LARGE WASTE RECEPTACLE

A3 RECYCLING RECEPTACLE

D1 U-SHAPED DESK, COMMANDER

D2 U-SHAPED DESK

E1 EX DESK, COMMANDER

E2 EX DESK

E3 EX WORKSTATION, RECEPTION

E4 EX DESK CHAIR, COMMANDER

E4A EX DESK CHAIR

E5 EX CONFERENCE CHAIR

E6 EX GUEST CHAIR

E7 EX LOUNGE CHAIR

E8 EX CONFERENCE TABLE

E9 EX SIDE TABLE

E10 EX MEETING TABLE

E11 EX COFFEE TABLE

E12 EX LATERAL FILE

E13 EX WARDROBE

E14 EX CREDENZA

E15 EX LECTERN

F1 STORAGE CABINET

F2 CREDENZA, 48"W

F3 CREDENZA, 60"W

M1 MICROWAVE

M2 REFRIGERATOR, FULL SIZE

M3 REFRIGERATOR, COMPACT

M4 LECTERN

S1 DESK CHAIR

S2 GUEST CHAIR

S3 CONFERENCE CHAIR

S4 TRAINING CHAIR

S5 BREAK CHAIR

S6 STOOL

S7 LOUNGE CHAIR

S8 RECLINER

T1 CONFERENCE TABLE, 120"W

T2 BREAK TABLE, 30"W

T3 CONFERENCE TABLE, 84"W

T4 CONFERENCE TABLE, 144"W

T5 BREAK TABLE, 36"W

T6 CLASSROOM TABLE

T7 CLASSROOM TABLE, SMALL

T8 SIDE TABLE

W1 WORKSTATION

W2 WORKSTATION, HOTELING

W3 WORKSTATION, TRAINING

W4 WORKSTATION, ADMINISTRATIVE

NOTES:

1. FURNITURE LAYOUT IS CONCEPTUAL AND MAY NOT COMMUNICATE

ALL REQUIREMETNS AS DESCRIBED IN THE RFP. SIGNIFICANT

CHANGES IN FURNITURE LAYOUT SHALL BE APPROVED BY THE

GOVERNMENT.

2. PROCUREMENT AND INSTALLATION OF FF&E (EXCLUDING THE

COMMAND SUITE FF&E) IS A BID OPTION. PROCUREMENT AND

INSTALLATION OF COMMAND SUITE FF&E IS A SEPARATE BID OPTION.

SEE 01 81 00 FOR ADDITIONAL INFORMATION ON BID OPTIONS.

3. SEE ROOM DATA SHEETS AND FF&E FOR ADDITIONAL FURNITURE

REQUIREMENTS.

4. SEE APPENDIX L - FURNISHINGS, FIXTURES, & EUIPMENT (FF&E)

PACKAGE FOR LOCATION OF A1 SMALL WASTE RECEPTACLE.

5. PRINTERS AND VENDING MACHINES ARE NOT IN CONTRACT.

US Army Corps of Engineers ® Omaha District

SHEET ID

U S

AR

M

Y C

O R

PS

O

F

EN

G

IN

EE

R

S

D R

A W N

B Y:

D

ES

IG

N

ED

B

Y:

SU

B M

IT

TE

D B

Y:

SI

ZE

C H

E C

KE

D B

Y:

AN

S I

'D

FI

LE

N

AM

E:

IS

SU

E D

AT

E :

C O

N

TR

AC

T

N O

SO

L I

C

IT

AT

IO

N N

O

FI

LE

N U

M

BE

R

1 2 3 4 5

D

C

B

A

BU

C

KL

EY

A

FB

, C O

LO

R

AD

O

PN

C

R W

U

0 2

(F Y1

8)

I-112

FI

R

ST

F

LO

O

R F

U R

N

IT

U R

E

PL

AN

A R

EA

B

S B

IR

S, O

PE

R

AT

IO

N

AL

S U

PP

O

R T

FA

C

IL

IT

Y

O M

A H A

D

IS

T R

IC

T O

M

AH

A, N

EB

R

AS

KA

K.

R

IE

G

E

K.

R

IE

G

E

B.

G

O R

U P

-1

0-

W

F-

-R

-0

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

0 20'10'5'

PLAN NORTH

AREA "B"

KEYPLAN - FIRST FLOOR

3/32" = 1'-0"I-112

1 FIRST FLOOR FURNITURE PLAN - AREA B

GENERAL
G-001 COVER
G-002 INDEX
G-003 ABBREVIATIONS
G-004 LEGEND
G-005 ELECTRICAL LEGEND
G-006 LOCATION PLAN
G-007 COMPOSITE FREE ZONE PLAN
G-008 SOF CONSTRUCTION - FREE ZONE
G-009 GENERATOR BUILDING - FREE ZONE
G-010 BUILDING DEMOLITION - FREE ZONE
GEOTECHNICAL
B-100 SOIL BORING LOCATION PLAN
B-301 SOIL BORING LOGS - DRILL HOLES BU16-13 THROUGH BU16-18
SITE/CIVIL
VF100 OVERALL EXISTING CONDITIONS PLAN
VF101 EXISTING CONDITIONS PLAN - AREA 101
VF102 EXISTING CONDITIONS PLAN - AREA 102
VF103 EXISTING CONDITIONS PLAN - AREA 103
VF104 EXISTING CONDITIONS PLAN - AREA 104
VF105 EXISTING CONDITIONS PLAN - AREA 105
VF106 EXISTING CONDITIONS PLAN - AREA 106
VF107 EXISTING CONDITIONS PLAN - AREA 107
VF108 EXISTING CONDITIONS PLAN - AREA 108
CD102 SITE DEMOLITION PLAN - AREA 102
CD103 SITE DEMOLITION PLAN - AREA 103
CD105 SITE DEMOLITION PLAN - AREA 105
CD106 SITE DEMOLITION PLAN - AREA 106
UD102 UTILITY DEMOLITION PLAN - AREA 102
UD103 UTILITY DEMOLITION PLAN - AREA 103
UD105 UTILITY DEMOLITION PLAN - AREA 105
CS100 OVERALL SITE PLAN
CS104 SITE PLAN - AREA 104
CS105 SITE PLAN - AREA 105
CU100 OVERALL UTILITY PLAN
CU104 UTILITY PLAN - AREA 104
CU105 UTILITY PLAN - AREA 105
CU107 UTILITY PLAN - AREA 107
CU108 UTILITY PLAN - AREA 108
MECHANICAL SITE
MS101 MECHANICAL SITE PLAN DIESEL FUEL PIPING AREA 101
MS104 MECHANICAL SITE PLAN DIESEL FUEL PIPING AREA 104
MS105 MECHANICAL SITE PLAN NATURAL GAS PIPING AREA 105
ELECTRICAL SITE
ED100 ELECTRICAL DEMOLITION PLAN - COMPOSITE
ED101 ELECTRICAL DEMOLITION PLAN - AREA 101
ED102 ELECTRICAL DEMOLITION PLAN - AREA 102
ED103 ELECTRICAL DEMOLITION PLAN - AREA 103
ED104 ELECTRICAL DEMOLITION PLAN - AREA 104
ED105 ELECTRICAL DEMOLITION PLAN - AREA 105
ED106 ELECTRICAL DEMOLITION PLAN - AREA 106
ES100 ELECTRICAL SITE PLAN - COMPOSITE
ES101 ELECTRICAL SITE PLAN - AREA 101
ES104 ELECTRICAL SITE PLAN - AREA 104
ES105 ELECTRICAL SITE PLAN - AREA 105
ES106 ELECTRICAL SITE PLAN - AREA 106
ES600 ELECTRICAL UTILITY ONE-LINE DIAGRAM
TO100 TELECOMMUNICATIONS SITE PLAN - COMPOSITE
TO101 TELECOMMUNICATIONS SITE PLAN - AREA 101
TO102 TELECOMMUNICATIONS SITE PLAN - AREA 102
TO103 TELECOMMUNICATIONS SITE PLAN - AREA 103
TO104 TELECOMMUNICATIONS SITE PLAN - AREA 104
TO105 TELECOMMUNICATIONS SITE PLAN - AREA 105
TO106 TELECOMMUNICATIONS SITE PLAN - AREA 106
TO200 TELECOMMUNICATIONS UTILITY EXISTING GIS DIAGRAM - WIDE AREA
TO201 TELECOMMUNICATIONS UTILITY EXISTING GIS DIAGRAM - BUILDING 26 AREA
TO202 TELECOMMUNICATIONS UTILITY EXISTING GIS DIAGRAM - BUILDING 447 AREA
TO203 TELECOMMUNICATIONS UTILITY EXISTING GIS DIAGRAM - BUILDING 850 AREA
TO600 TELECOMMUNICATIONS OUTSIDE PLANT ONE-LINE DIAGRAM
TO601 TELECOMMUNICATIONS OUTSIDE PLANT RISER DIAGRAM
TY100 CCTV ROUTING SITE PLAN - COMPOSITE
TY600 ACS AND IDS DETAILS
ARCHITECTURAL
A-110 CONCEPT FLOOR PLAN - COMPOSITE
A-110EPF CONCEPT EMERGENCY POWER FACILITY FLOOR PLAN
A-111 CONCEPT FLOOR PLAN - AREA A
A-112 CONCEPT FLOOR PLAN - AREA B
A-120 CONCEPT ROOF PLAN - COMPOSITE
A-201 CONCEPT BUILDING ELEVATIONS
A-210 ENLARGED CONCEPT BUILDING ELEVATIONS
A-211 CONCEPT BUILDING ELEVATIONS - AREA "A"
A-212 CONCEPT BUILDING ELEVATIONS - AREA "B"
A-900 CONCEPT BUILDING ELEVATIONS - AREA "A"
A-901 CONCEPT BUILDING ELEVATIONS - AREA "B"
INTERIORS
I-110 FIRST FLOOR FURNITURE PLAN - COMPOSITE
I-111 FIRST FLOOR FURNITURE PLAN - AREA A
I-112 FIRST FLOOR FURNITURE PLAN - AREA B