3P- A

SURFACE MOUNTED

PNL "LB" PNL "L1"

PNL "L2" PNL "L3"

PNL "L4" PNL "ELEV"

FACP PNL "C"

SPARE

SPARE

SPACE SPACE

SPACE SPACE

SPACE

SPACE SPACE

CONNECTED LOAD: KVA

DEMAND FACTOR:

DEMAND LOAD: KVA

DEMAND AMPS: A

MAIN DIST PNL

SPACE

31 32

PANEL:

FEEDER:

DP

3.0

MAIN BUS:

22,000

208Y/120V 3PH 4W

BOLT-ON

AIC RATING:400

VOLTAGE:

MAIN BRKR:

BRKR TYPE:

POLE

1.1

4.4

P C

4.4

POLES:

NEMA ENCL:

DESCRIPTION

KVA

A B

3.0

3.0

1.1

1.0

1.0

1.1

1.0

403 8

A

4.4

BRKR

B C

1.1

1.1

2.3

SPACE

15.2

DESCRIPTION

TR

KVA

POLE

COND

201.0

0.8

72.4

96.6

SPACE

4.0

SPACE SPACE36

BRKR

COND

P TR

4.0

4.0

2.3

3 40 8

2.3

200 3/0

15.2

3 50 6

15.2

1.1

3P- A

SURFACE MOUNTED

L-NORTH STAIR AREA L-EAST STAIR AREA

L-UTILITY AREA L-WEST STAIR AREA

L-SOUTH AISLE L-NORTH AISLE, RAMP

L-ENTRY SPARE

SPARE

R-B108 R-B101

R-B109 SP-2

EF-1 R-NORTH (SP-2)

FCU-3 SP-1

PFB PFB

PFB PFB

PFB PFB

PFB PFB

PFB PFB

CONNECTED LOAD: KVA * SWD TYPE BIRCUIT BREAKER

DEMAND FACTOR: ** OPTION 2: ADD PARKING GUIDANCE SYSTEM.

DEMAND LOAD: KVA IF OPTION 4 IS NOT AWARDED, PROVIDE 1P20A SPARE

R-B107 (PARK GUID)

DP-1,3,5

20 11.2

12**17

0.5 1 1018

0.7 115 0.2 1 20 12

20 12

20 12

113 0.2 1 20 0.8

12 12 0.2 1 1 20

11 0.5 1 20

**9 0.4 1 20 1.0

7 1.5 1 20

13.3

13.3

1.00

PFB29 PFB

1.010 8

12 10

12 14

*5 1.2 1 201.2 1 20 10

*3 0.8 11 20 12

1 20 12

20*4 0.6

1 20*1 0.7

B C

0.7

BRKR TYPE: BOLT-ON NEMA ENCL:

BRKR

COND POLE DESCRIPTION

P

A

KVA

COND

TR

10,000

PANEL: VOLTAGE: 208Y/120V 3PH 4WLB POLES: 36

AIC RATING:

CTR B

*6

POLE

*2

100 MAIN BRKR:

FEEDER:

P

DESCRIPTION

MAIN BUS:

KVA BRKR

A

3P- A

SURFACE MOUNTED

SPARE

SPARE

PFB PFB

CONNECTED LOAD: KVA * SWD TYPE BIRCUIT BREAKER

DEMAND FACTOR: ** OPTION 3: ADD TEMPORARY PARKING AREA.

DEMAND LOAD: KVA IF OPTION 3 IS NOT AWARDED, L1-8,10 PFB ONLY

1.0

208Y/120V 3PH 4W POLES: 18

10,000

5 L-ENTRY

11.9

PFB

*3 L-NORTH AISLE, RAMP

11.9

1.0

17 PFB

1.5 2 20 8

1.6 1 20

10 2

20 10 4

*1 L-SOUTH AISLE 1.2 1 0.220 1 20 12

BRKR

CONDPOLE

P TRA B C

DESCRIPTION

KVA BRKR

A B C P

PANEL: L1 VOLTAGE:

FEEDER: DP-2,4,6 BRKR TYPE:

TR

MAIN BUS: 100 AIC RATING:MAIN BRKR:

BOLT-ON NEMA ENCL:

DESCRIPTION

KVA

R-LOBBY 101

1.5

L-NORTH PARKING LOT

PFB

COND POLE

PFB PFB

PFB

1.0

1.0 81.5

1.5

2 20

**10

1 20 L-SOUTH PARKING LOT

**8

3P- A

SURFACE MOUNTED

CONNECTED LOAD: KVA * SWD TYPE BIRCUIT BREAKER

DEMAND FACTOR:

DEMAND LOAD: KVA

PANEL: L2 VOLTAGE: 208Y/120V 3PH 4W POLES: 12

MAIN BUS: 100 MAIN BRKR: 40 AIC RATING: 10,000

FEEDER: DP-7,9,11 BRKR TYPE: BOLT-ON NEMA ENCL: 1

POLE DESCRIPTION

KVA BRKR

COND POLE DESCRIPTION

KVA BRKR

COND

B C P TRA B C P TR A

*1 L-SOUTH AISLE 1.2 1 20 12 2 R-LOBBY 201 0.2 1 20 12

*3 L-NORTH AISLE, RAMP 1.1 1 20 12 4 PFB

5 SPARE 1.0 1 20 6 PFB

7 PFB

9 PFB

8 PFB

10 PFB

12 PFB11 PFB

3.4

1.0

3.4

3P- A

SURFACE MOUNTED

CONNECTED LOAD: KVA * SWD TYPE BIRCUIT BREAKER

DEMAND FACTOR:

DEMAND LOAD: KVA3.4

1.0

3.4

PFB12PFB11

PFB10PFB9

PFB8PFB7

PFB62011.0SPARE5

PFB4122011.1L-NORTH AISLE, RAMP*3

122010.2R-LOBBY 3012122011.2L-SOUTH AISLE*1

COND

TRBA PCBA

DESCRIPTIONPOLEDESCRIPTIONPOLE

BRKRKVABRKRKVA

COND

TRPC

1NEMA ENCL:BOLT-ONBRKR TYPE:DP-8,10,12FEEDER:

10,000AIC RATING:40MAIN BRKR:100MAIN BUS:

12POLES:208Y/120V 3PH 4WVOLTAGE:L3PANEL:

3P- A

SURFACE MOUNTED

CONNECTED LOAD: KVA

DEMAND FACTOR:

DEMAND LOAD: KVA

DEMAND AMPS: A

DESCRIPTION

20 12 2 R-LOBBY 401

PANEL: L4 VOLTAGE: 208Y/120V 3PH 4W POLES: 12

MAIN BUS: 100 MAIN BRKR: 40 AIC RATING: 10,000

FEEDER: DP-13,15,17 BRKR TYPE: BOLT-ON NEMA ENCL: 1

POLE DESCRIPTION

KVA BRKR

COND POLE

KVA BRKR

COND

C P TRA B C P TR A B

1 L-POLES 1.2 2 1.3 1 20 12

3 0.2 4 ACCU-2 2.5 2 40 8

5 L-EMERG 0.2 1 20 12 6 2.5

7 SPARE 1.0 1 20

PFB8

9 PFB

PFB

11 PFB PFB

8.9

1.0

8.9

24.7

3P- A

SURFACE MOUNTED

CONNECTED LOAD: KVA ** OPTION 1: PROVIDE ELECTRICAL SUPPORT FOR ELEVATOR #2

DEMAND FACTOR: IF OPTION 1 IS NOT AWARDED, PROVIDE PFB IN SPACES 2,4,6,8

DEMAND LOAD: KVA

DEMAND AMPS: A

15 ELEV PIT 0.3 1 20 SPARE 1.0

ELEVATOR CAR 0.5

20 12 18

20 12

17 ELEV PIT 0.3 1

R-ELEV MACH RM

1.0 1 20

1 20

19 PFB 20

20 12

PFB

20 12

20 12

SUMP PUMP SP-1 0.8 1

SF-2 0.2

FCU-2 0.5

PFB

121 20

L-ELEV MACH RM 0.2 1

EF-2 0.2 1

0.5 1 20

1.0 1 20 12

**6

ELEVATOR CAR

24PFB

57.1

0.8

45.7

PFB

126.8

15.05 1.8

2/0

15.0

3 **4

1.8

ELEVATOR MOTOR 15.0**230 8

**8

PFB

SPARE

1 ELEVATOR MOTOR 1.9 3

A B C P TR A B C

COND

P TR

POLE DESCRIPTION

KVA BRKR

COND POLE DESCRIPTION

KVA BRKR

DP-14,16,18 BRKR TYPE: BOLT-ON NEMA ENCL: 1

POLES: 18

AIC RATING: 10,000

PANEL: ELEV VOLTAGE: 208Y/120V 3PH 4W

MAIN BUS: 225 MAIN BRKR:

FEEDER:

3P- A

SURFACE MOUNTED

CONNECTED LOAD: KVA ** OPTION 2: INCREASE ELECTRICAL SUPPORT FOR ACCU-1

DEMAND FACTOR: IF OPTION 2 IS NOT AWARDED, PROVIDE 2P-25A CB, #10 COND, SHOW

DEMAND LOAD: KVA LOAD AS 1.7 KVA/PHASE

DEMAND AMPS: A

8.6

0.8

6.9

19.1

17 PFB

PFB

PFB

18 PFB

1615 PFB

13 PFB

12 PFB11 PFB

20 10 PFB

1 20 12

9 SPARE 1.0 1

20 8 SF-1 0.2

2.4

7 SPARE 1.0 1

20 12 6

2 40 8

5 FCU-1 0.5 1

20 12 *4 ACCU-1 2.4

1 20 12

3 R-B107 (PARK GUID) 0.4 1

20 12 2 R-B107 0.41 R-B107 0.4 1

A B C P TR TR

DESCRIPTION

KVA BRKR

COND

A B C P

POLE DESCRIPTION

KVA BRKR

COND POLE

FEEDER: DP-20,22,24 BRKR TYPE: BOLT-ON NEMA ENCL: 1

POLES: 18

AIC RATING: 10,000

PANEL: C VOLTAGE: 208Y/120V 3PH 4W

MAIN BUS: 100 MAIN BRKR: 50

16sb04_SBHC-Parking-Structure_E-001
16sb04_SBHC-Parking-Structure_ED101
16sb04_SBHC-Parking-Structure_ES101
16sb04_SBHC-Parking-Structure_ES102
16sb04_SBHC-Parking-Structure_ES103
16sb04_SBHC-Parking-Structure_ES104
16sb04_SBHC-Parking-Structure_ES501
SHEET ES502 Manhole Details
SHEET ES503 Manhole Details
SHEET ES504 Site Electrical Details
SHEET ES505 Traffic Details
16sb04_SBHC-Parking-Structure_EL101
16sb04_SBHC-Parking-Structure_EL102
16sb04_SBHC-Parking-Structure_EL103
16sb04_SBHC-Parking-Structure_EL501
16sb04_SBHC-Parking -Structure_EL502
16sb04_SBHC-Parking-Structure_EP101
16sb04_SBHC-Parking-Structure_EP601
16sb04_SBHC-Parking-Structure_EP602
16sb04_SBHC-Parking-Structure_EP603
16sb04_SBHC-Parking-Structure_EP604
16sb04_SBHC-Parking-Structure_EY101
16sb04_SBHC-Parking-Structure_EY102
16sb04_SBHC-Parking-Structure_EY103
16sb04_SBHC-Parking-Structure_EY601
16sb04_SBHC-Parking-Structure_TELECOMMUNICATIONS_04 NOV 15_RTA.pdf
16sb04_SBHC-Parking-Structure_TD101
16sb04_SBHC-Parking-Structure_TS101
SHEET T-101 Telecommunications Plan

File details come from the government source that posted it. Updated .