Attachment 4 - Drawings 11 Technology.pdf

PDF 1 MB Posted

Attached to
Eglin NICoE Initial Outfitting Project
Solicitation number
W9127S20Q6000
Issued by

About this file

This is a combined synopsis and solicitation for commercial items issued by the Department of the Army Corps of Engineers Engineering District Little Rock. It requests quotes for the Eglin NICoE Initial Outfitting Project to outfit a new facility on Eglin Air Force Base. Quotes are due by January 8, 2020 at 1:00 PM Central Time. A site visit is scheduled for December 4, 2019 at 9:00 AM Central Time at the Eglin AFB West Visitors Center. This is a total Service-Disabled Veteran-Owned Small Business set-aside with a NAICS code of 337127 and size standard of 500 employees. Interested contractors must RSVP for the site visit by November 29, 2019 at 11:00 AM Central Time and provide contact information for base access. More details are available in the combined synopsis and solicitation attachments.

View the file

Other files

File Type Posted
Amendment 2 Attachment 10 - Site Visit Sign-In.pdf PDF
Amendment 2 Attachment 3A - Project Room Contents_25Dec2019.pdf PDF
Amendment 2 Attachment 2A - Cut Sheets (Salient Features_Specs).pdf PDF
W9127S20Q6000 AMENDMENT 0002.pdf PDF
Amendment 2 Attachment 1 - Bid Schedule.xlsx XLSX spreadsheet
Amendment 2 Attachment 8 - ESS_Video_Surveillance_VSS (ProjNet ID 8304557).pdf PDF
Amendment 2 Attachment 9 - Sound_Masking_Systems (ProjNet ID 8304607).pdf PDF
Amendment 2 Attachment 11 - ProjNet Questions_Answers.pdf PDF
Amendment 1 Attachment 2 - Cut Sheets (Salient Features_Specs).pdf PDF
Amendment 1 Attachment 3 - Project Room Contents.pdf PDF
W9127S20Q6000 Amendment 0001.pdf PDF
Amendment 1 Attachment 1 - Bid Schedule (Amendment 01).xlsx XLSX spreadsheet
Amendment 1 Attachment 4 - Eglin Invisible Wounds Clinic (IWC)_As-Built Drawings.pdf PDF
Attachment 1 - Bid Schedule.xlsx XLSX spreadsheet
Attachment 4 - Drawings 06 Mechanical.pdf PDF
Attachment 4 - Drawings 09 Fire Protection.pdf PDF
Attachment 4 - Drawings MEDICAL EQUIPMENT.pdf PDF
Attachment 4 - Drawings 08 Fire Alarm.pdf PDF
Attachment 2 - Cut Sheets.pdf PDF
Attachment 4 - Drawings 10 Electrical.pdf PDF
Attachment 4 - Drawings Specifications Vol 2.pdf PDF
Attachment 4 - Drawings 01 General.pdf PDF
W9127S20Q6000 - Combined Synopsis Solicitation NICoE - Eglin AFB IO Project.pdf PDF
Attachment 5 - Reuse List.xlsx XLSX spreadsheet
Attachment 7 - IO&T Submittal Examples.pdf PDF
Attachment 6 - DMLSS RPIE List.xls XLS spreadsheet
Attachment 4 - Drawings 02 Civil.pdf PDF
Attachment 4 - Drawings 07 Plumbing.pdf PDF
Attachment 4 - Drawings FFE.pdf PDF
Attachment 4 - Drawings 05 Architecture.pdf PDF
Attachment 4 - Drawings FURNITURE.pdf PDF
Attachment 3 - Project Room Contents_15Nov2019.pdf PDF
Attachment 4 - Drawings Specifications Vol 1.pdf PDF
Attachment 4 - Drawings 03 Landscape Arch.pdf PDF
Attachment 4 - Drawings 04 Structure.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TECHNOLOGY SYMBOL LIST

SYMBOL: DESCRIPTION: NOTE:

EQUIPMENT

LIST ABBREV.:

C#

W

C#

C#

1.INFORMATION OUTLET (CEILING)SC-IO-C

1.INFORMATION OUTLET (WALL)SC-IO-W

.WALL PHONESC-IO-W

1., 3.INFORMATION OUTLET (FLOOR)SC-IO-F

RI

.INFORMATION OUTLET ROUGH-IN (WALL)SC-RI-W

CSS

CR1 2.CREDENTIAL READER - TYPE 1AC-CR1-W

2.

CONTROLLED SECURITY SCHEME SCHEDULE

IDENTIFIER

DR SECURITY DURESS/PANIC BUTTON (WALL)AC-DR-W .

DR SECURITY DURESS/PANIC BUTTON (SURFACE)AC-DR-S .

EDR ELECTRONIC DOOR RELEASE (WALL)AC-EDR-W .

N/A

WP1 .AUDIO/VISUAL FACEPLATE (WALL) - TYPE 1AV-WP1-W

ND2

D NURSE CALL - DOME LIGHT (WALL)

STAFF ASSIST BUTTON

ND1 .NURSE CALL - MASTER STATION

NC-D-W

NC-ND2-W

NC-ND1-W

TECHNOLOGY ABBREVIATION KEY

ENTRANCE FACILITYEF-#

MAIN CROSS-CONNECTMC-#

TELECOMMUNICATIONS ROOMTR-#

ABOVE FINISHED FLOORAFF

BELOW FINISHED CEILINGBFC

CONDUITC

SIMILARSIM

TYPICALTYP

MOUNTING HEIGHT ABOVE FINISHED FLOOR+#

JUNCTION BOXJ-BOX

ABBR: DESCRIPTION:

UNLESS NOTED OTHERWISEUNO

TECHNOLOGY GENERAL NOTES:

1. ###-### INDICATES GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ITEM LABELED AS

"EQUIPMENT LIST ABBREVIATION"

2. REFER TO GENERAL TECHNOLOGY EQUIPMENT SCHEDULE AND SPECIFICATIONS FOR FULL

DESCRIPTIONS AND MANUFACTURERS OF ALL DEVICES.

TECHNOLOGY MOUNTING SUBSCRIPT KEY:

A MOUNT AT +6" TO CENTERLINE ABOVE COUNTER OR BACKSPLASH

H MOUNT ORIENTED HORIZONTALLY

L MOUNT IN CASEWORK

M MOUNT IN MODULAR FURNITURE

S MOUNT IN SURFACE RACEWAY

A SLASH IS USED BETWEEN TWO SUBSCRIPTS, E.G., A/H.

1. THE COMPLETE INSTALLATION SHALL BE IN ACCORDANCE WITH THE ADA STANDARDS FOR

ACCESSIBLE DESIGN. REFER TO THE ADA GUIDELINES FOR ALL CONFIGURATION DETAILS

ON THIS PAGE FOR ADDITIONAL INFORMATION.

2. CONCEAL ALL CONDUIT IN WALLS, PARTITIONS, ABOVE CEILING, IN FLOOR SLAB, ETC.

UNLESS OTHERWISE INDICATED ON THE PLANS OR IN THE SPECIFICATIONS. CONDUIT IN

MECHANICAL ROOMS AND STORAGE ROOMS WITHOUT CEILINGS MAY BE EXPOSED ON

BUILDING STRUCTURE.

3. BOXES LOCATED ON OPPOSITE SIDES OF NON-RATED WALLS SHALL BE OFFSET A MINIMUM

OF 6" HORIZONTALLY. BOXES ON OPPOSITE SIDES OF FIRE RATED WALLS SHALL BE

OFFSET A MINIMUM OF 24" HORIZONTALLY. "THRU-THE-WALL" BOXES SHALL NOT BE

ALLOWED WITHOUT PRIOR WRITTEN APPROVAL OF THE ARCHITECT/ENGINEER.

4. VERIFY ALL FURNITURE, MODULAR FURNITURE, AND EQUIPMENT LOCATIONS WITH

ARCHITECTURAL PLANS, ELEVATIONS, AND REVIEWED SHOP DRAWINGS. PRIOR TO MAKING

THE ACTUAL TELECOMMUNICATIONS INSTALLATION, ADJUST OUTLETS OR CONNECTION

LOCATIONS TO ACCOMMODATE FURNITURE AND/OR EQUIPMENT.

5. TELECOMMUNICATIONS EQUIPMENT SHALL BE MOUNTED TO ALLOW ACCESS TO

ELECTRICAL AND MECHANICAL EQUIPMENT. ALL MOUNTING OF TELECOMMUNICATION

DEVICES ON EQUIPMENT SUPPLIED BY ANOTHER CONTRACTOR SHALL BE APPROVED IN

ADVANCE BY THE OTHER CONTRACTOR.

6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL OPENINGS REQUIRED IN WALLS. ALL

OPENINGS SHALL BE REPAIRED TO MATCH EXISTING BY A QUALIFIED CONTRACTOR AT THE

EXPENSE OF THIS CONTRACTOR. ALL CONDUITS THROUGH WALLS SHALL BE GROUTED OR

SEALED INTO OPENINGS.

7. ALL MATERIALS USED TO SEAL PENETRATIONS OF FIRE RATED WALLS AND FLOORS SHALL

BE TESTED AND CERTIFIED AS A SYSTEM PER ASTM E814 STANDARDS FOR FIRE TESTS OF

THROUGH-PENETRATION FIRESTOPS. REFER TO DIVISION 7 FOR ADDITIONAL INFORMATION

AND REQUIREMENTS SPECIFIC TO FIRESTOPPING.

8. REMOVE AND REINSTALL ALL CEILING TILES AS REQUIRED FOR THE EXECUTION OF

TELECOMMUNICATIONS WORK THAT IS OUTSIDE THE CONTRACT LIMITS OF CONSTRUCTION.

REPLACE CEILING TILES WITH IDENTICAL MATERIAL WHERE DAMAGED BY THIS

CONTRACTOR.

9. FLUSH MOUNT ALL TELECOMMUNICATION OUTLETS AT +18" FROM FLOOR (CENTERLINE

DIMENSION), EXCEPT WHERE OTHERWISE NOTED. OUTLETS MAY BE SURFACE MOUNTED

WHEN CONDUIT IS SPECIFIED EXPOSED.

TECHNOLOGY INSTALLATION NOTES:

GENERAL NOTES:

1. ALL SYMBOLS AND ABBREVIATIONS LISTED MAY NOT BE APPLICABLE TO THIS PROJECT.

REFER TO THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE FOR MORE COMPLETE

DESCRIPTION AND ITEMS.

2. ALL SYMBOLS AND ABBREVIATIONS REFER TO TECHNOLOGY SHEETS ONLY AS DEFINED ON

THE SHEET INDEX. REFER TO THE GENERAL TECHNOLOGY NOTES FOR ADDITIONAL

INFORMATION.

3. ALL SYMBOLS LISTED ABOVE ARE FOR REFERENCE ONLY. REFER TO PLANS AND LINE TYPE

KEY FOR NEW, EXISTING TO REMAIN AND TO BE REMOVED ITEMS FOR ADDITIONAL

INFORMATION.

TECHNOLOGY SYMBOL NOTES:

1. "C#" INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO

INFORMATION OUTLET SCHEDULE ON T7.1 AND RISER ON 1/T5.1 FOR ADDITIONAL

INFORMATION.

2. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T7.1 AND DOOR

ROUGH-IN DETAIL AT 5/T6.1 FOR ADDITIONAL INFORMATION.

3. INFORMATION OUTLET INSTALLED IN E.C. PROVIDED FLOOR BOX. "C#" INDICATES

INFORMATION OUTLET FACEPLATE CONFIGURATION. REFER TO INFORMATION OUTLET

SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION. REFER TO THE ELECTRICAL FLOOR

PLANS AND ELECTRICAL EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.

CABLE TRAY, CHANNEL TRAY, BASKET

TRAY

LADDER RACK

WIDTH X HEIGHT

WIDTH X HEIGHT

DIAMETERø C CONDUIT

CONDUIT DOWN

CONDUIT UP OR UP/DOWN

CONDUIT SLEEVE

CONTINUATION

PLAN OR DETAIL NUMBER

PLAN OR DETAIL NAME

PLAN OR DETAIL SCALE

NAME

VIEW NAME

1/8" = 1'-0"

T4.1

SIM

DETAIL REFERRED TO BY ELEVATION

SHEET DETAIL IS LOCATED ON

INDICATES SIMILAR DETAIL

REFERENCED IN MULTIPLE LOCATIONS

LEVEL NAME

10' - 0" HEIGHT ABOVE

PROJECT 0' - 0"

1 INDICATES NOTE USED TO DESCRIBE

ADDITIONAL INFORMATION ABOUT

WORK REQUIRED, SPECIFIC TO THE

SHEET AND/OR DETAIL

N

O R HT

INDICATES DIRECTION OF TRUE NORTH

VIEW KEY

NEW WORK BY THIS CONTRACTOR

(DARK SOLID LINE)

NEW WORK UNDERFLOOR OR UNDERGROUND BY THIS CONTRACTOR

(DARK LONG DASHED LINE)

NEW WORK BY OTHERS AND/OR EXISTING TO REMAIN

(LIGHT SOLID LINE)

EXISTING TO BE REMOVED BY THIS CONTRACTOR

(DARK SHORT DASHED LINE)

LINE TYPE KEY:

SECURITY CONTRACTORS.C.

NURSE CALL CONTRACTORN.C.C.

CIVIL CONTRACTORC.C.

GENERAL CONTRACTORG.C.

MECHANICAL CONTRACTORM.C.

ELECTRICAL CONTRACTORE.C.

CONTRACTOR ABBREVIATION KEY

ABBR: DESCRIPTION:

TECHNOLOGY CONTRACTORT.C.

CONSTRUCTION MANAGERC.M.

M

A X

20" MAX.

M

A X

20"-25" MAX.

M

A X

M

IN

. 4

M

A X

M

A X

10" MAX. 10"-24" MAX.

ADA GUIDELINES - FRONT ACCESS

ADA STANDARDS FOR ACCESSIBLE DESIGN

INSTALL ABOVE COUNTER

DEVICE AT 44" ABOVE

FINISHED FLOOR.

INSTALL ABOVE COUNTER

DEVICE AT 40" ABOVE

FINISHED FLOOR.

INSTALL DEVICE AT 18"

ABOVE FINISHED FLOOR.

ADA GUIDELINES - SIDE ACCESS

INSTALL DEVICE AT 44"

ABOVE FINISHED FLOOR.

INSTALL DEVICE AT 42"

ABOVE FINISHED FLOOR.

SUGGESTED MATRIX OF RESPONSIBILITY

ITEM: SHOWN ON:

FURNISHED

BY:

INSTALLED

BY: NOTES:

TECHNOLOGY ROUGH-IN, REFER TO

GENERAL TECHNOLOGY EQUIPMENT

SCHEDULE AND SPECIFICATIONS FOR

DEFINITION

T-SERIES E.C. E.C. 3. 4.

INFORMATION OUTLET FACEPLATES,

JACKS, AND TERMINATIONS

T-SERIES T.C. T.C.

CONDUIT SLEEVES (WHEN SHOWN ON

DRAWINGS)

T-SERIES E.C. E.C.

CONDUIT SLEEVES (NOT SHOWN BUT

REQUIRED FOR PROPER INSTALLATION

OF SYSTEM)

N/A T.C. T.C. 2. 4.

TELECOMMUNICATION SYSTEMS

ROUGH-IN

T-SERIES E.C. E.C. 1.

TELECOMMUNICATION EQUIPMENT,

CABLING, AND TERMINATIONS

T-SERIES T.C. T.C.

NURSE CALL ROUGH-IN T-SERIES N.C.C. E.C.

NURSE CALL EQUIPMENT, CABLING,

AND TERMINATIONS

T-SERIES N.C.C.

CABLE TRAY (INCLUDING WIRE BASKET

TRAY) REFER TO SPECIFICATION

SECTION 27 05 28 FOR DEFINITION

T-SERIES E.C. E.C.

LADDER RACK T-SERIES T.C. T.C. 5.

GROUNDING LUGS ON TECHNOLOGY

EQUIPMENT

T-SERIES T.C. E.C. 6.

BONDING SYSTEM FOR TECHNOLOGY

SYSTEM, REFER TO SPECIFICATION

SECTION 27 05 26 FOR DEFINITION

T-SERIES E.C. E.C. 7. 8.

CONNECTION OF TECHNOLOGY

BONDING SYSTEM TO THE ELECTRICAL

GROUND SYSTEM

T-SERIES E.C. E.C.

LINE VOLTAGE POWER (+120V OR

GREATER)

E-SERIES E.C. E.C.

LINE VOLTAGE POWER (NOT SHOWN

BUT REQUIRED FOR PROPER

INSTALLATION OF SYSTEM)

N/A T.C. E.C. 2. 4.

LINE VOLTAGE POWER FOR DOOR

HARDWARE POWER SUPPLIES

ARCH SPEC E.C. E.C.

LOW VOLTAGE CABLING FOR

TECHNOLOGY SYSTEMS

T-SERIES T.C. T.C.

CABLE HANGERS AND SUPPORTS OR

OTHER CABLE ROUTING METHODS

(OTHER THAN CONDUIT AND CABLE

TRAY)

T-SERIES T.C. T.C. 5.

TECHNOLOGY SERVICE ENTRANCE

CONDUITS, HANDHOLES, AND

MANHOLES

T-SERIES E.C. E.C.

FLOOR BOX (ROUGH-IN) T & E SERIES E.C. E.C.

SUGGESTED MATRIX OF RESPONSIBILITY NOTES

1. LOCATIONS OF TELECOMMUNICATIONS ROUGH-INS SHALL BE INDICATED BY THE INFORMATION

OUTLET SYMBOLS ON THE DRAWINGS. REFER TO THE TECHNOLOGY SYMBOL LIST FOR

ADDITIONAL INFORMATION.

2. BASED ON THE INHERENT DIFFERENCES IN PRODUCTS FROM VARIOUS MANUFACTURERS, ALL

REQUIRED EQUIPMENT MAY NOT BE SHOWN ON THE DRAWINGS FOR ALL ACCEPTABLE

MANUFACTURERS.

3. INCLUDES BACKBOXES AND CONDUIT REQUIRED FOR THE TECHNOLOGY SYSTEMS

INSTALLATION. THE E.C. SHALL BASE THE BID ON THE BASIS OF DESIGN SHOWN ON THE

CONTRACT DOCUMENTS.

4. ALL CHANGES TO THE SLEEVES, BACKBOXES, CONDUITS, AND POWER REQUIRED BECAUSE OF

THE T.C.'S SELECTION OF AN ALTERNATE ACCEPTABLE MANUFACTURER OR FROM SYSTEM

CONFIGURATIONS THAT ARE LEFT TO THE CHOICE OF THE CONTRACTOR SHALL BE INCLUDED

IN THE T.C.'S BID. THIS BID SHALL INCLUDE INSTALLATION BY A LICENSED ELECTRICIAN.

5. UNLESS TRADE RULES DICTATE OTHERWISE.

6. FURNISHED AS PART OF THE EQUIPMENT WHEN POSSIBLE, OR FURNISHED TO THE E.C. FOR

INSTALLATION IN THE FIELD.

7. INCLUDES ALL CONDUCTORS, GROUND BARS, AND TERMINATIONS FOR THE COMPLETE

BONDING SYSTEM REQUIRED BY THE SPECIFICATIONS.

8. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF PANELS AND SWITCHBOARDS SHOWN

IN THE TECHNOLOGY BONDING RISER DIAGRAM AND TYPICAL TELECOM ROOM BONDING FLOW

DIAGRAM.

TELECOM ROOM REFERENCES

TELECOM ROOM

DETAIL / SHEET

REFERENCE

FLOOR PLAN

REFERENCE ARCH ROOM NUMBER

TR-1 1/T4.1 T2.1 324

TR-2 4/T4.1 T2.1 211

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

As indicated

/1

/2

:5 :0

P

M TECHNOLOGY

ABBREVIATIONS AND

SYMBOLS

T0.1

10822.000

TECHNOLOGY SHEET INDEX

T0.1 TECHNOLOGY ABBREVIATIONS AND SYMBOLS

T2.1 GROUND FLOOR PLAN - TECHNOLOGY

T4.1 ENLARGED PLANS - TECHNOLOGY

T5.1 RISER DIAGRAMS - TECHNOLOGY

T6.1 DETAILS - TECHNOLOGY

T7.1 SCHEDULES - TECHNOLOGY

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2018 IMEG CORP.

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com

18003094.00

Contract Documents 01.04.2019

C

C

C2-WAP

W

W

C 2C

C

W

C2-WAP

C2

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAP

C2-WAPC2-WAP

C

C

C 2C

RI

C2

C

C

C

C

C2

C2

C2

C

C 2C

C

C

C

C2C2

C2 C2

C2

C2

C2-WAP

C2-WAP

C

C

C

C

C

C 2 C

C

C 2 C

C2

C

C2

C

C

C

C

C

C

C2

C

C

C2

C

C

C

C2 C

C2 C2

C2

W

C4

C2

C2C2

C2 C2 C2

C2 C2 C2

RI

C -T

V

C -T

V

C

C

C -T

V

RI

C -T

V

C -T

V

RI

CR1

CSS

C

C

CSS

CR1

CR1

C S

S

C R

CR1

C R

CR1

C R

C R

CR1

CR1

C S

S

C S

S

CSS

CSS

CSS

C S

S

CSS

C S

S

CSS

C S

S

CSS CSS

CSS

W P

W P

W P

W P

W P

E D

R

D D

DD

D D

D

D

D

D

D D

D

D

D

D D

D

DD

D

ND2 ND2

ND2

N D

N D

N

D

ND2

ND2

N D

ND2

ND2ND2ND2

ND2

ND2

N D

N D

ND2

ND2

ND2

N D

N

D

N D

ND2ND2ND2

ND2 ND2 ND2

ND2

ND2

N D

D

D D

N D

D

N D

N D

D

DR

DRDR

DR

DR

DR

DR

DR

D

C

C

C

C2 C2

C

C2

C2

C2C2

C

DR

DR

DR

DR

DR

DR DR DR

DR

C2 DR

DR

DR

DR

DR

DR

DR

DR

DR

DR

DR

DR

DRDRDR

DR DR DR

DR

DR

W P

C -T

V

DR

DR

DR

DR

DR

DR

C

W P

C -T

V

DR

DRDR

DR

DR DR

DR

W P

WP1W

P

C -T

V

C1-TV

C -T

V

C2

C2DR

C2

W P

C

- T

V

C2

C

C

DR

W P

W

P

C -T

V C

-T

V

C

C

C2

C2

C

W P

W

P

C

C1

C

C

C

C

C1

C -T

V

W P

C

CR1 CR1

CR1

C

W P

W P

C

W P

W P

W P

W P

W P

C -T

V

W P

W

P

W P

W

P

W P

N D

ND2

ND2

D

DR

C R

C2

C1

C1

C

C

W P

1 W P

WP1

W P

W P

W P

C

W P

C2

W

123456789

B

C

D

E

F

A

A.7

A.2

6.97.1 6.26.5 5.4 4.5 3.6 2.8

D.7

5.2 4.88.6 8.3 6.8 6.4

0.9A

0.2A

0.3A

0.4A

0.5A

0.6A

E.8

B2

A.9

0.7A

MECHANICAL

ELEC

TLT/ SHR

218.2

CHANGING / LOCKER (M)

CHANGING / LOCKER (W)

VESTIBULE

COMM

PUBLIC WAITING

C101

SOIL UTIL

WORKSTATION PT

TLT/ SHR

218.1

CORRIDOR

C300

CORR

C301

CORR

C305

CORR

C304

CORR

C302

CORR

C306

CORR

C201

CORR

C200

CORR

C202

MAT / PLATFORM

PT GYM

GAIT OBS LANE

CORR

C303

NEURO REHAB AREA

FAMILY WAITING

CENTRAL PARK

TREATMENT IPMC

DAYROOM

SOIL UTIL

CASE MGMT

CLEAN UTIL

CORR

C102.1

EYE TESTING

EXAM

SCALE

C306.1PAT TLT

STAFF TLT

EXAM

GROUP THERAPY

TEAM ROOM

EXAM

HOUSEKEEPING

PAT TLT

BRAIN LAB

ELEC

TRANS-CRANIAL MAGNETIC STIM

COMM

ACUPUNCTURE

341.1

SPIRITUAL COUNSELLING

NP PSYCH

NEUROPSYCH

ACUPUNCTURE

341.2

BH / SW PROVIDERS

BH / SW PROVIDERS

PSYCHOLOGIST

CHIRO TREATMENT

CASE MGMT

STAFF LOUNGE

EXAM

MUSIC THERAPY

CHIRO TREATMENT

RECEPTION

PTNT INTAKE CUBICLES

300.1

CASE MGMT

ART AND CLAY THERAPY

MALE TOILET

FEMALE TOILET

HOUSEKEEPING

MULTI-STATION TREATMENT RM

PT O/E

PT O/E

DAILY LIVING SKILLS

BREAK ALCOVE

105.1

RESEARCH SHARED OFFICE

NCOIC / ADMIN

NICoE DIR.

DIR. OF OPERATIONS

AV SUPPLY

CLASSROOM

103.1

CHAPLAIN

CLASSROOM

EYE LANE

EXAM

PSYCH TECH

PSYCH TECH

STAFF TLT

SPEECH THERAPY - OFFICE

OT O/E

TRAZER / FATS

SPEECH THERAPY - TESTING

OT O/E

NEUROLOGIST

PC MD

CLINICAL PHARMACIST

EXAM

EXAM

PAIN MD

NUTRITIONIST

GROUP THERAPY

335.1

BIO NEUROFEEDBACK

FLEX STORAGE

VENDING ALCOVE

106.1

CORR

C102

STORAGE / KILN

338.1

TLT / SHR

219.1

BH / SW PROVIDER

4A

4B

5.

8.

318 349 34

EQPT STOR

EXAM

EQPT STOR

8.

8.

219.1

C

2A

C102

103 10

7B

C

0A

217A

C100A

C

C100B

STORAGE / ALCOVE

200.1

C100

ALCOVE / STORAGE

C303.1

MAIN CORRIDOR / LOBBY

C100

C102.1

3.

T4.1

T4.1

TR-1

TR-2

SC-CT-1 (TYP)

SC-CT-1 (TYP)

+108"

+108"

+108"

CABLING ON THIS SIDE TO TR-1

CABLING ON THIS SIDE TO TR-2

CABLING ON THIS SIDE TO TR-1

CABLING ON THIS SIDE TO TR-2

PRINTER

PYXIS

MACHINE

PRINTER

AC-DRK-1 1

12"x4"

"x

"x

12"x4"12"x4"

+60"+60"

+60"

+60"

+60"

+60"

+60" +60"

+60" +60"

+60" +60"

+60"

+60"

+60"+60"

+60" +60"

+60" +60"

+60" +60"

+60"

+60"

+60"

+60"

+60"

+60"

+60"

+60"

+108"

AC-DRK-1

+60" +60"

12"x4"

"x

"x

"x

12"x4"

12"x4"

"x

"x

12"x4"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48" +48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48"

+48" +48"

+48" +48"

+48"

+48"+42" +48"

+48"

+48"

+48"

+48" +48"

WALL MOUNTED

WIRELESS

DURESS BUTTON

AV-VPS-1

AV-PRO-MNT-1

AV-PRO-1

HANDHOLE AND CONDUIT DUCTBANK

ROUTED INTO BUILDING. REFER TO

ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION.

BUILDING CONTRACTOR TO ROUTE AND

TERMINATE 24 SM FIBER INTO BUILDING.

FIBER AND SLACK COIL WILL BE PROVIDED

BY BASE CONTRACTOR AND LEFT AT

HANDHOLE FOR INSTALLATION. REFER TO

1/T5.1 FOR ADDITIONAL INFORMATION

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

1/8" = 1'-0"

/1

/2

:5 :0

P

M GROUND FLOOR

PLAN - TECHNOLOGY

T2.1

10822.000

N

O R HT

1/8" = 1'-0"1

GROUND FLOOR PLAN - TECHNOLOGY

GENERAL SHEET NOTES :

1. CONTRACTOR TO PROVIDE A 15' SLACK COIL

AT THE NEAREST SUPPORT ABOVE EVERY

ROOM CONTAINING ONLY ONE INFORMATION

OUTLET LOCATION TO ALLOW FOR CABLING

TO BE RE-ROUTED TO THE OTHER SIDE OF

THE ROOM AT A LATER DATE BY THE OWNER.

KEYNOTES:

1. PROVIDE (2) 1" CONDUITS DOWN COLUMN FOR

ROUTING OF LOW VOLTAGE CABLING FROM

ABOVE CEILING, INTO MILLWORK, AND

THROUGH MILLWORK TO TERMINATION

LOCATION.

2. INSTALL INFORMATION OUTLET IN MILLWORK.

ROUTE CABLING THROUGH MILLWORK AND

THROUGH CONDUIT STUB UP IN FLOOR. REFER

TO ELECTRICAL DRAWINGS FOR ADDITIONAL

PATHWAY INFORMATION.

3. PROVIDE HDMI CABLE FROM WALL PLATE TO

HDMI EQUALIZER MOUNTED AT PROJECTOR.

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2018 IMEG CORP.

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com

W

W

NC-NCP-1 AC-SCP-1

SC-GND-1

SC-TTB

(TYP)

T4.1

SC-ER-1

SC-VWM-1

(TYP)

(TYP)

NOTES:

1. REFER TO 2/T4.1 FOR PATHWAY PLAN.

TV-TVT-4

SC-FDC-1

(PROVIDE WALL

MOUNT BRACKET)

NOTES:

1. PLACE ALL EQUIPMENT IN ITS DESIGNATED RACK AS DEFINED BY THIS LAYOUT UNLESS

OTHERWISE NOTED. ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE

BASIS OF DESIGN MANUFACTURER AND ARE THE MINIMUM REQUIREMENTS.

COORDINATE WITH THE OWNER AND THE ENGINEER FOR ANY CHANGES PRIOR TO

MODIFICATION OF THIS LAYOUT. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE

ON T7.1 AND SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. ALL EMPTY SPACES ARE FOR OWNER SUPPLIED EQUIPMENT (HUBS, SWITCHES, PATCH

PANELS, ETC.) UNLESS OTHERWISE NOTED.

SC-MPP-1

SC-HWM-1

SC-FDC-1

SC-VWM-1

SC-ER-1

(TYP)

(TYP)

(TYP)

(TYP)

SC-LR-1

(TYP)1

"x

"x

"x

12"x2"

12"x2"

(4) 4" CONDUIT SLEEVES

(2) 3" CONDUITS ROUTED TO

TR-2 OVERHEAD IN CEILING

SPACE FOR FIBER AND

COPPER BACKBONE CABLING

SC-GND-1

SC-TTB

T4.1

NOTES:

1. REFER TO 5/T4.1 FOR PATHWAY PLAN.

AC-SCP-1

SC-VWM-1

SC-ER-1

TV-TVT-4

SC-LR-1

(TYP)

"x

"x

"x

12"x2"

12"x2"

(4) 4" CONDUIT

SLEEVES

(2) 3" CONDUITS ROUTED TO TR-1

OVERHEAD IN CEILING SPACE FOR

FIBER AND COPPER BACKBONE

CABLING

NOTES:

1. PLACE ALL EQUIPMENT IN ITS DESIGNATED RACK AS DEFINED BY THIS LAYOUT UNLESS

OTHERWISE NOTED. ALL EQUIPMENT IS SIZED (BY RACK UNITS) ACCORDING TO THE

BASIS OF DESIGN MANUFACTURER AND ARE THE MINIMUM REQUIREMENTS. COORDINATE

WITH THE OWNER AND THE ENGINEER FOR ANY CHANGES PRIOR TO MODIFICATION OF

THIS LAYOUT. REFER TO THE TECHNOLOGY EQUIPMENT SCHEDULE ON T7.1 AND

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. ALL EMPTY SPACES ARE FOR OWNER SUPPLIED EQUIPMENT (HUBS, SWITCHES, PATCH

PANELS, ETC.) UNLESS OTHERWISE NOTED.

SC-MPP-1

SC-HWM-1

SC-FDC-1

SC-VWM-1

SC-ER-1

(TYP)

(TYP)

(TYP)

(TYP)

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

As indicated

/1

/2

:5 :0

P

M ENLARGED PLANS -

TECHNOLOGY

T4.1

10822.000

N

O R HT

1/4" = 1'-0"1

TECHNOLOGY ROOM 324 LAYOUT - TR-1

1" = 1'-0"3

EQUIPMENT RACK ELEVATION - TR-1

N

O R HT

1/4" = 1'-0"2

TECHNOLOGY ROOM 324 PATHWAY - TR-1

N

O R HT

1/4" = 1'-0"4

TECHNOLOGY ROOM 211 LAYOUT - TR-2

N

O R HT

1/4" = 1'-0"5

TECHNOLOGY ROOM 211 PATHWAY - TR-2

1" = 1'-0"6

EQUIPMENT RACK ELEVATION - TR-2

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2018 IMEG CORP.

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com

SC-MPP-1

OWNER

PROVIDED

EQUIPMENT

SC-FDC-1

SC-MPP-1

OWNER

PROVIDED

EQUIPMENT

SC-FDC-1

SC-FDC-1

AC-SCP-1

AC-DRK-1 AC-DRK-1 AC-DR-S

TV-TVT-4

TV-TVT-4

OWNER

PROVIDED PC

OWNER

PROVIDED

TELEVISION

GROUND

FLOOR

TELECOMMUNICATIONS ROOM (TR-1)

TELECOMMUNICATIONS ROOM (TR-2)

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES

OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION(S),

LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE

OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING

INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. REFER TO FLOOR PLANS FOR QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT

EACH INFORMATION OUTLET.

3. ALL CABLING SHALL BE 23 GAUGE, 4-PAIR, CATEGORY 6, UNSHIELDED TWISTED PAIR

CABLE UNLESS OTHERWISE NOTED. REFER TO SPECIFICATIONS SECTION 27 15 00 FOR

ADDITIONAL INFORMATION.

CEILING SPACE

4 4

C#-WAP

C#

C#

W

KEYNOTES:

1. REFER TO PLANS FOR QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT EACH

INFORMATION OUTLET. REFER TO THE INFORMATION OUTLET SCHEDULE ON T7.1 FOR

ADDITIONAL INFORMATION. REFER TO ELECTRICAL FLOOR PLANS AND ELECTRICAL

EQUIPMENT SCHEDULE FOR ADDITIONAL INFORMATION.

2. RACK OR CABINET AS DEFINED ON THE TELECOM ROOM LAYOUT. REFER TO THE

TELECOM ROOM REFERENCES MATRIX ON THE COVERPAGE FOR LOCATION.

3. RJ-45 TO RJ45 CATEGORY 6 UTP PATCH CORDS PROVIDED BY CONTRACTOR AND

INSTALLED BY OWNER. REFER TO SPECIFICATIONS.

4. REFER TO COVER SHEET AND FLOOR PLANS FOR TELECOMMUNICATIONS ROOM

LOCATIONS.

5. 24 STRAND SINGLE MODE FIBER COILED IN HANDHOLE BY OWNER TO BE ROUTED INSIDE

AND TERMINATED BY CONTRACTOR. COORDINATE WITH 96 CS/SCXP PRIOR TO

COMMENCING THIS WORK.

6. 24 STRAND SINGLE MODE FIBER.

7. FIBER PATCH CORDS FURNISHED BY CONTRACTOR AND INSTALLED BY OWNER.

C#-WAP

C#

C#

W

WALL MOUNTED

5 X-BUS

+14 VDC

CAT6

CAT6

CAT6

CONSOLE

CIRCUIT

NC-NCP-1

ND2

D

D

D

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN

FOR CLARIFICATION OF CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN THE AREA SHOWN. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING INFORMATION. REFER TO SPECIFICATIONS FOR

ADDITIONAL REQUIREMENTS. REFER TO FLOOR PLANS FOR QUANTITY OF DEVICES.

2. POWER FOR CONTROL DEVICES AND LOCAL CONSOLES TO BE PROVIDED IN LOCATIONS AS PER MANUFACTURER'S REQUIREMENTS.

ND2

ND2

ND1

(TYP)

(TYP)

(TYP)

(TYP)

DOOR ROUGH-IN DIAGRAM

(SINGLE DOORS)

NOTES:

1. DOOR # DESIGNATES THE ACCESS CONTROL SCHEME AT EACH DOOR LOCATION. REFER TO T7.1 FOR

REQUIREMENTS.

2. THIS RISER IS DIAGRAMMATIC AND NOT INTENDED TO SHOW ACTUAL ROUTING OR QUANTITIES OF MATERIALS

SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND CABLE TYPE. THIS RISER WILL NOT REPLICATE ALL DOOR CONFIGURATIONS. REFER TO SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS.

3. REFER TO ARCHITECTURAL DRAWING FOR DETAILS.

4. POWER FOR THE DOOR HARDWARE WILL COME FROM THE ACCESS CONTROL PANEL.

KEYNOTES:

1. MOUNT AC-SCP-1 ACCORDING TO MANUFACTURER SPECIFICATIONS. REFER TO SPECIFICATION SECTION 28 13 00

FOR ADDITIONAL INFORMATION.

2. ELECTRIC DOOR STRIKE BY OTHERS. CONTRACTOR SHALL PROVIDE 18AWG 2-CONDUCTOR NON-SHIELDED

WIRING AND TERMINATIONS FROM DOOR STRIKE TO SECURITY CONTROLLER.

3. DOOR CONTACT SWITCH AND CABLE. CONTRACTOR SHALL PROVIDE 18AWG 2-CONDUCTOR WIRING FROM

CONTACT SWITCH TO SECURITY CONTROLLER.

4. PROVIDE POWER AS REQUIRED BY MANUFACTURER.

5. TYPICAL WIRELESS DURESS. PROVIDE QUANTITY AS SHOWN ON FLOOR PLANS.

6. PROGRAM EMERGENCY DURESS TO LOCK-DOWN ACCESS CONTROLLED DOORS.

7. CARD READER CABLING. CONTRACTOR SHALL PROVIDE 18AWG 9-CONDUCTOR SHIELDED WIRING AND

TERMINATIONS FROM DOOR STRIKE TO SECURITY CONTROLLER.

8. ELECTRONIC DOOR HARDWARE POWER CABLING. CONTRACTOR SHALL PROVIDE 18AWG 2-CONDUCTOR NON-

SHIELDED WIRING AND TERMINATIONS FROM DOOR STRIKE TO SECURITY CONTROLLER.

9. EMERGENCY DURESS CABLING. CONTRACTOR SHALL PROVIDE 18AWG 2-CONDUCTOR NON-SHIELDED WIRING

AND TERMINATIONS FROM DOOR STRIKE TO SECURITY CONTROLLER.

OWNER

NETWORK

TO HOSPITAL

SERVER

ROOM

CARD READER

AT 48" AFF

A

F F

CONNECT ACCESS CONTROL

PANEL TO FIRE ALARM

CONTROL PANEL VIA AN

ADDRESSABLE RELAY

CR1

EDR 6

PROVIDE CONNECTION TO BUILDING

SERVICE SINGLE MODE FIBER FOR

NOTIFICATIONS TO BE ROUTED TO

CENTRAL SECURITY OFFICE

INTERCONNECT PANELS PER

MANUFACTURER RECOMMENDATION

9 8

REQUEST TO EXIT

CONNECTION (TYP)

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW

ACTUAL ROUTING OR QUANTITIES OF MATERIALS

SHOWN. THIS RISER IS SHOWN FOR CLARIFICATION OF

CONNECTION(S), LOCATIONS AND CABLE TYPE. ALL

INFORMATION OUTLETS ARE TYPICAL OF THE OUTLETS IN

THE AREA SHOWN. REFER TO DRAWINGS FOR ACTUAL

QUANTITIES OF INFORMATION OUTLETS AND MORE

SPECIFIC ROUTING INFORMATION. REFER TO

SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

2. SERVICE PROVIDER TO PROVIDE CATV SYSTEM.

3. ALL CROSS-CONNECTIONS BY SERVICE PROVIDER.

KEYNOTES:

1. RG-6 HORIZONTAL CABLE RUNS FROM

TELECOMMUNICATIONS ROOMS TO OUTLET LOCATIONS

FURNISHED AND INSTALLED BY CONTRACTOR. REFER TO

SPECIFICATIONS FOR CABLE REQUIREMENTS.

2. REFER TO DRAWINGS FOR QUANTITY OF LOCATIONS AND

QUANTITY OF CABLES AND JACKS TO BE INSTALLED AT

EACH INFORMATION OUTLET LOCATION.

3. CONTRACTOR FURNISHED AND INSTALLED RG-11 COAX

CABLE.

4. INCOMING SERVICE CABLE BY SERVICE PROVIDER.

COORDINATE EXACT LOCATION WITH SERVICE

PROVIDER.

TR-2

C#-TV

C#-TV

TR-1

C#-TV

C#-TV

NOTES:

1. THIS FLOW DIAGRAM IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF

MATERIALS SHOWN. THIS DIAGRAM IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS AND CABLE TYPE. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING AND QUANTITY INFORMATION.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

VGA, HDMI, USB, AUDIO CABLE

(1) 1 1/4" CONDUIT,

POPULATE WITH VGA,

HDMI, USB, AND AUDIO

CABLES

HDMI CABLE

WP1

WP1

REFER TO ARCHITECTURAL DRAWINGS

FOR MOUNTING HEIGHT AND LOCATION

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

12" = 1'-0"

/1

/2

:5 :0

P

M RISER DIAGRAMS -

TECHNOLOGY

T5.1

10822.000

NO SCALE1

FIBER AND COPPER RISER DIAGRAM

NO SCALE2

NURSE CALL CONTROL MODULE WIRING DIAGRAM

NO SCALE3

ACCESS CONTROL/DURESS RISER DIAGRAM

NO SCALE4

CATV RISER DIAGRAM

NO SCALE5

PC TO TV/MONITOR CONNECTION DIAGRAM

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2018 IMEG CORP.

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com

SC-GND-1

NEAREST

ELECTRICAL

PANEL

METALLIC

CONDUITS

AND SLEEVES

EQUIPMENT

RACK(S)

BUILDING

STEEL

CABLE TRAY

(CONTINUOUS

BOND)

LADDER RACK

(CONTINUOUS

BOND)

SC-GND-1 SC-GND-1

MOLDED POLYESTER -

FIBERGLASS INSULATOR

COPPER GROUND CONDUCTOR

FROM BUILDING SERVICE GROUND.

REFER TO SPECIFICATIONS FOR

DETAILS

TWO HOLE COMPRESSION LUG

NOTES:

1. REFER TO TECHNOLOGY EQUIPMENT SCHEDULE SC-GND-1 FOR WIDTH REQUIREMENTS.

2. REFER TO 2/T6.1 FOR TELECOMMUNICATIONS ROOM BONDING CONNECTION DIAGRAM.

COPPER BONDING CONDUCTOR TO

EQUIPMENT RACKS, CABLE TRAYS &

METALLIC SLEEVES. REFER TO

SPECIFICATIONS FOR DETAILS

BARE COPPER GROUND BAR,

INSULATORS, BRACKETS AND

BONDING PROVIDED BY E.C.

REFER TO TECHNOLOGY

EQUIPMENT SCHEDULE SC-GND-1

5/16" Ø

(TYP)

7/16" Ø

(TYP)

TO ELECTRICAL ENTRANCE FACILITY.

REFER TO 3/T6.1 FOR

TELECOMMUNICATIONS BONDING RISER

DIAGRAM FOR CONTINUATION AND

ADDITIONAL INFORMATION. THIS

CONNECTION ONLY HAPPENS IN THE

TR-1. REFER TO THE COVER SHEET AND

THE FLOOR PLANS FOR TR-1 LOCATION

TELECOMMUNICATIONS BONDING

BACKBONE (TBB). REFER TO 3/T6.1 FOR

TELECOMMUNICATIONS BONDING RISER

DIAGRAM

TELECOMMUNICATIONS

BONDING JUMPER (TBJ)

TELECOMMUNICATIONS ROOM (TR-#), (TYP)

NOTES:

1. THIS FLOW DIAGRAM IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR QUANTITIES OF

MATERIALS SHOWN. THIS DIAGRAM IS SHOWN FOR CLARIFICATION OF CONNECTION LOCATIONS

AND CABLE TYPE. REFER TO FLOOR PLANS FOR MORE SPECIFIC ROUTING AND QUANTITY

INFORMATION. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. ALL CONDUCTORS IN THE TELECOMMUNICATIONS SYSTEM SHALL BE 3/0 AWG COPPER (GREEN OR

MARKED WITH A DISTINCTIVE GREEN COLOR) UNLESS CONDUCTOR DISTANCE IS LESS THAN 66

FEET. REFER TO 3/T6.1 BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR

CONDUCTORS LESS THAN 66 FEET IN LENGTH. REFER TO SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS..

3. ALL BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY COMPRESSION

LUGS, EXOTHERMIC WELDING, OR IRREVERSIBLE COMMUNICATIONS BONDING CONDUCTORS TO

EQUIPMENT. WHERE NECESSARY REMOVE PAINT AND/OR USE PAINT-PIERCING WASHERS TO

PROVIDE PROPER ELECTRICAL BOND AT ALL CONNECTIONS.

4. BONDING TO PAINT TREATED SURFACES SHALL UTILIZE PANT PIERCING LUGS.

5. REFER TO THE TELECOMMUNICATIONS BONDING BUS BAR DETAIL ON 1/T6.1 FOR ADDITIONAL

INFORMATION FOR THE SC-GND-1.

KEYNOTES:

1. REFER TO T0.1 FOR TELECOMMUNICATIONS ROOM NUMBERS AND LOCATIONS.

TELECOMMUNICATIONS

BONDING JUMPER (TBJ)

CONDUCTOR

LENGTH IN FEET

BONDING CONDUCTOR SIZING SCHEDULE

MINIMUM ACCEPTABLE

SIZE - AWG

LESS THAN 13' 6

14' - 20' 4

21' - 26' 3

27' - 33' 2

34' - 41' 1

42' - 52' 1/0

53' - 66' 2/0

3/0

NOTES:

1. THIS RISER IS DIAGRAMMATIC AND MAY NOT SHOW ACTUAL ROUTING OR

QUANTITIES OF MATERIALS SHOWN. THIS RISER IS SHOWN FOR

CLARIFICATION OF CONNECTION LOCATIONS AND CABLE TYPE. REFER TO

FLOOR PLANS FOR SPECIFIC ROUTING AND QUANTITY INFORMATION.

REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

2. ALL CONDUCTORS IN THE TELECOMMUNICATIONS BONDING SYSTEM

SHALL BE MINIMUM SIZE OF 3/0 AWG PLENUM RATED COPPER

CONDUCTORS (GREEN OR MARKED WITH A DISTINCTIVE GREEN COLOR)

UNLESS CONDUCTOR LENGTH IS LESS THAN 66 FEET. REFER TO BONDING

CONDUCTOR SIZING SCHEDULE FOR SIZING CRITERIA FOR CONDUCTORS.

3. BONDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED

BY EXOTHERMIC WELDING, LISTED PRESSURE CONNECTORS, LISTED

CLAMPS OR OTHER LISTED MEANS. SOLDER IS NOT AN ACCEPTABLE

MEANS OF CONNECTION. SHEET METAL SCREWS SHALL NOT BE USED TO

CONNECT COMMUNICATIONS BONDING CONDUCTORS TO EQUIPMENT.

4. REFER TO 2/T6.1 FOR TELECOMMUNICATIONS ROOM BONDING

CONNECTION DIAGRAM.

5. REFER TO T0.1 FOR TELECOMMUNICATIONS ROOM REFERENCES.

GROUND

FLOOR

EXISTING ELECTRICAL

ENTRANCE FACILITY

EXISTING GROUNDING ELECTRODE

CONDUCTOR. COORDINATE

CONNECTION WITH ELECTRICAL

CONTRACTOR

EXISTING ELECTRICAL

GROUNDING

ELECTRODE SYSTEM

TELECOMMUNICATIONS

BONDING BACKBONE

(TBB) (TYP)

BONDING CONDUCTOR FOR TELECOMMUNICATIONS (BCT). BCT SHALL

BE AT LEAST THE SAME SIZE AS THE TBB OR LARGER. REFER TO

BONDING CONDUCTOR SIZING SCHEDULE FOR SIZING REQUIREMENTS.

THIS CONNECTION OCCURS IN THE TR-1 ROOM ONLY

TR-1 TR-2

67' - 84'

REFER TO

ARCHITECTURAL

PLANS FOR WALL

CONSTRUCTION

SINGLE GANG PLASTER

RING TO COME WITHIN 1/8"

OF FINAL SURFACE

STUD

1 1/4" EMT CONDUIT. REFER

TO DETAIL NOTES FOR

ADDITIONAL REQUIREMENTS

NYLON BUSHING

J-HOOK

NOTES:

1. 1 1/4" EMT CONDUIT SHALL STUB UP TO NEAREST ACCESSIBLE CEILING AND TERMINATE ORIENTED

HORIZONTALLY AT THE HEIGHT OF THE ASSOCIATED CABLE TRAY OR J-HOOK ROUTE. CONDUIT RUN SHALL NOT CONTAIN MORE THAN 180 DEGREES OF BEND BETWEEN ACCESSIBLE JUNCTION BOXES OR

BETWEEN JUNCTION BOX AND END OF CONDUIT.

2. WHERE CONDUIT STUB IS LOCATED IN A ROOM WITH AN ACCESSIBLE CEILING AND IS NOT REQUIRED TO RUN TO CABLE ROUTE LOCATED OUTSIDE THE ROOM, STUB MUST TERMINATE ABOVE THE ACCESSIBLE CEILING WITH A 90-DEGREE BEND AT THE TOP ORIENTED IN TO THE ROOM AT THE HEIGHT OF THE

ASSOCIATED CABLE TRAY OR J-HOOK ROUTE IN THE ROOM.

3. ALL STUBS MUST BE FITTED WITH A NYLON BUSHING ON EACH END OF THE CONDUIT.

4. INSTALLING CONTRACTOR SHALL FURNISH AND INSTALL FIRESTOP MATERIALS FOR TECHNOLOGY

ROUGH-INS PER PROJECT REQUIREMENTS. REFER TO SPECIFICATIONS FOR FIRESTOP REQUIREMENTS.

NOTES:

1. CONFIGURATIONS SHOWN IN THE DETAIL ABOVE ARE DIAGRAMMATIC, INTENDED TO DESCRIBE THE CONTROLLED SECURITY SCHEME ROUGH-IN

REQUIREMENTS OF THE DOORS. DETAILS ABOVE MAY NOT ACCURATELY REPRESENT DOOR SIZE, DOOR SWING, DOOR HARDWARE, OR DOOR FUNCTIONALITY. REFER TO ARCHITECTURAL DOOR HARDWARE SCHEDULE, DOOR HARDWARE GROUPS AND DOOR HARDWARE SPECIFICATIONS

FOR COMPLETE INFORMATION. MIRROR THE DETAIL AS REQUIRED.

2. ROUGH IN SHOWN IN THE DETAIL ABOVE REPRESENTS THE MINIMUM REQUIREMENTS FOR ALL CONTROLLED SECURITY SYSTEM DEVICES AND CABLING UNLESS OTHERWISE NOTED. COORDINATE EXACT REQUIREMENTS WITH SELECTED DOOR MATERIALS, DOOR HARDWARE, AND

CONTROLLED SECURITY DEVICES AND CABLING PRIOR TO INSTALLATION.

3. ALL CABLING IN WALLS AND WHERE EXPOSED ON VERTICAL SURFACES SHALL BE INSTALLED IN EMT CONDUIT OR SURFACE MOUNT RACEWAY.

CABLING ROUTED HORIZONTALLY ABOVE THE ACCESSIBLE CEILING MAY BE INSTALLED FREE-AIR CABLING PROPERLY RATED FOR THE CEILING

ENVIRONMENT.

4. THE ELECTRICAL OR SECURITY CONTRACTOR SHALL NOT MODIFY ANY FIRE RATED DOOR AND/OR DOOR FRAME. REFER TO THE ARCHITECTURAL DOOR SCHEDULE, DOOR HARDWARE SCHEDULE, AND DOOR HARDWARE SPECIFICATION FOR ADDITIONAL INFORMATION. MODIFICATION TO ANY FIRE RATED DOOR AND/OR FRAME WILL REQUIRE A RE-CERTIFICATION OF THE DOOR AND FRAME WITH THE LOCAL AUTHORITY HAVING

JURISDICTION (AHJ).

5. INSTALLING CONTRACTOR SHALL FURNISH AND INSTALL FIRESTOP MATERIALS FOR ALL CONTROLLED SECURITY SCHEME ROUGH-INS PER PROJECT REQUIREMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.

6. REFER TO THE ACCESS CONTROL/DURESS RISER DIAGRAM ON T5.1 FOR CABLING REQUIREMENTS AND THE CONTROLLED SECURITY SCHEME

SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION.

7. INSTALLATION SHALL INCLUDE ALL POWER REQUIRED FOR SYSTEM OPERATION INCLUDING +120VAC ORIGINATING AT ACCESS CONTROL PANEL.

REFER TO THE SUGGESTED MATRIX OF SCOPE RESPONSIBILITY FOR ADDITIONAL INFORMATION.

KEYNOTES:

1. PROVIDE JUNCTION BOXES IN THE DOOR FRAME WHERE SHOWN ON THIS DETAIL. ROUGH-IN SHALL BE PROVIDED WHETHER THE CURRENT

SECURITY SCHEME UTILIZES THEM OR NOT. ALL CONDUITS SHALL BE EMT CONDUIT UNLESS OTHERWISE NOTED. FLEXIBLE CONDUIT OF ANY TYPE WILL NOT BE ACCEPTED. COORDINATE INSTALLATION WITH ON-SITE DOOR FRAME INSTALLATION CONTRACTOR.

2. ALL DOOR POSITION SWITCHES ARE REQUIRED TO BE RECESSED UNLESS OTHERWISE NOTED. ELECTRIC HINGE MONITORS ARE NOT AN

ACCEPTABLE REPLACEMENT FOR THE RECESSED DOOR POSITION SWITCH.

3. DOUBLE GANG BACKBOX WITH SINGLE GANG PLASTER RING. REFER TO FLOOR PLAN(S) FOR ACTUAL CREDENTIAL READER TYPE AND ROUGH-IN

LOCATIONS.

4. CONDUIT SHALL ROUTE FROM THE CREDENTIAL READER TO THE SECURE SIDE OF THE DOOR. CONDUIT SHALL ROUTE A MINIMUM OF 12" FROM THE

JUNCTION BOX. PROVIDE A NYLON BUSHING ON CONDUIT END.

5. MOUNT A MINIMUM 4" SQUARE 2-1/8" DEEP JUNCTION BOX WITH BLANK COVER PLATE ON THE SECURE SIDE OF THE DOOR ABOVE ACCESSIBLE CEILING. INSTALLING CONTRACTOR SHALL SIZE THE JUNCTION BOXES PER SYSTEM INSTALLATION REQUIREMENTS AND APPLICABLE CODES.

MAINTAIN ACCESS TO THE JUNCTION BOX.

6. PROVIDE A HORIZONTALLY MOUNTED SINGLE GANG BACKBOX FOR THE REQUEST TO EXIT SENSOR. REFER TO THE CONTROLLED SECURITY SCHEME

SCHEDULE ON T7.1 FOR DOORS THAT REQUIRE THIS ROUGH-IN.

7. CONDUIT SHALL ROUTE A MINIMUM OF 12" FROM THE JUNCTION BOX. PROVIDE A NYLON BUSHING ON CONDUIT END.

8. CONDUIT INSTALLED IN PERMANENT MULLIONS ONLY. REFER TO THE ARCHITECTURAL DOOR SCHEDULE AND DOOR HARDWARE GROUPS FOR

LOCATIONS THAT REQUIRE THIS ROUGH-IN. PROVIDE A NYLON BUSHING ON THE CONDUIT END.

DOOR FRAME ROUGH-IN DIAGRAM

(ALL SINGLE DOORS)

DOOR FRAME ROUGH-IN DIAGRAM

(ALL DOUBLE DOORS WITH OR WITHOUT MULLION)

FINISHED ACCESSIBLE

CEILING

MINIMUM 3/4" EMT CONDUIT

TO ABOVE THE

ACCESSIBLE CEILING

FINISHED FLOOR

CREDENTIAL READER

ROUGH-IN 3

DOOR CONTACT

ROUGH-IN

MINIMUM 1" EMT

CONDUIT

REQUEST TO

EXIT DEVICE

ROUGH-IN

1/2" EMT CONDUIT

MINIMUM (TYP.)

MINIMUM 1" EMT

CONDUIT

MINIMUM 3/4" EMT

CONDUIT TO ABOVE THE

ACCESSIBLE CEILING

CREDENTIAL READER

ROUGH-IN 3

REQUEST TO

EXIT DEVICE

ROUGH-IN

DOOR CONTACT

ROUGH-IN

5 5

4" 4" 4"

7 7

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

As indicated

/1

/2

:5 :0

P

M DETAILS -

TECHNOLOGY

T6.1

10822.000

NO SCALE1

TELECOMMUNICATIONS BONDING BUS BAR DETAIL

NO SCALE2

TELECOMMUNICATIONS

ROOM BONDING CONNECTION DIAGRAM

NO SCALE3

TELECOMMUNICATIONS BONDING RISER DIAGRAM

NO SCALE4

TECHNOLOGY ROUGH-IN MOUNTING DETAIL

NO SCALE5

CONTROLLED SECURITY SCHEME DOOR ROUGH-IN DETAIL

REFERENCE SCALE IN INCHES

0 1 2 3

PROJECT #

IMEG CORP RESERVES PROPRIETARY RIGHTS, INCLUDING COPYRIGHTS, TO THIS

DRAWING AND THE DATA SHOWN THEREON. SAID DRAWING AND/OR DATA ARE

THE EXCLUSIVE PROPERTY OF IMEG CORP AND SHALL NOT BE USED OR

REPRODUCED FOR ANY OTHER PROJECT WITHOUT THE EXPRESS WRITTEN

APPROVAL AND PARTICIPATION OF IMEG CORP. © 2018 IMEG CORP.

2882 106TH STREET

DES MOINES, IA 50322

515.334.9906 FAX: 515.334.9908

www.imegcorp.com

PAIR 2

PAIR 3

WG WOG O

ANSI/TIA/EIA T568A

PIN/PAIR ASSIGNMENT

PAIR 1 PAIR 4

BL WBL WBR BR

1 32 4 5 6 7 8

2-Port Faceplate

IDENTIFICATION

IDENTIFICATION

IDENTIFICATION

IDENTIFICATION

1 2

4-Port Faceplate

REFER TO SPECIFICATIONS FOR

IDENTIFICATION REQUIREMENTS (TYP.)

NUMBER INDICATES

FACEPLATE POSITION (TYP.)

I O W A

S E

D

PROFESS IONA

14628

L

IC

E N

L E

N G

I N E

E R

Jeffrey A.

Carpenter

DRAWING NUMBER

PROJECT NUMBER

SCALE

DRAWING TITLE

KEYPLAN

SEALS AND SIGNATURES

ISSUED FOR REV DATE

Cagley & Associates

STRUCTURAL ENGINEERING

6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050

1700 NEW YORK AVE, NW

SUITE 100

WASHINGTON, DC 20006

202.842.2100 www.smithgroup.com

P lo t D at e:

EGLIN AIR FORCE BASE

BUILDING XX

ASH DR, EGLIN AIR FORCE BASE

FLORIDA

32542

IMEG Corporation

ELECTRONIC SECURITY / TELECOMMUNICATIONS

2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906

Baskerville-Donovan, Inc.

CIVIL ENGINEERING

449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340

SmithGroup

MEP-FP ENGINEERING

1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100

12" = 1'-0"

/1

/2

:5 :0

P

M SCHEDULES -

TECHNOLOGY

T7.1

10822.000

THE EQUIPMENT LIST ABBREVIATIONS AND THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING SYSTEM.

CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS.

THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE.

GENERAL TECHNOLOGY EQUIPMENT SCHEDULE

EQUIPMENT LIST

ABBREVIATION EQUIPMENT LIST DESCRIPTION

EQUIPMENT LIST

MANUFACTURER AND MODEL

SC-VWM-1 VERTICAL WIRE MANAGER, REFER TO SC-ER-1 FOR ADDITIONAL INFORMATION. PANDUIT

WMPV45E

ORTRONICS

SYSTIMAX

SC-WP-W WALL MOUNTED INFORMATION OUTLET CONTAINING (1) RJ-45 JACK FOR VOICE AT +54" AFF FOR WALL HUNG PHONE. PROVIDE

WITH STAINLESS STEEL FACEPLATE, MATING LUGS.

INSTALL INFORMATION OUTLET IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. INSTALL A 1 1/4" EMT CONDUIT

ABOVE ACCESSIBLE CEILING.

HUBBELL

P630S1G

BELDEN

SYSTIMAX

SIEMON

HUBBELL/MOHAWK

ORTRONICS

MOLEX

LEVITON

TV-TVT-4 4-PORT DIRECTIONAL COUPLER/TAP. 5-1000 MHZ FREQUENCY RANGE, RF SHIELDING, DIE CAST HOUSING, ISOLATION OUTPUTS

AND THRU-LINE LOSSES WILL VARY. REFER TO 4/T5.1 FOR ADDITIONAL INFORMATION.

VALUES ARE PROVIDED PER CONTRACTOR REQUIREMENTS/DESIGN.

BLONDER TONGUE

SRT-4

RL DRAKE

CHANNEL MASTER

THE EQUIPMENT LIST ABBREVIATIONS AND THE GENERAL TECHNOLOGY EQUIPMENT SCHEDULE ARE FOR THE CONVENIENCE OF THE CONTRACTOR. EACH CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFICATION OF QUANTITIES AND SHALL FURNISH ALL MATERIAL REQUIRED, WHETHER SPECIFIED OR NOT, TO PRODUCE A SATISFACTORY WORKING SYSTEM.

CATALOG NUMBERS ARE NOT TO BE CONSIDERED COMPLETE BUT ARE GIVEN ONLY TO AID THE CONTRACTOR IN THE SEARCH FOR MATERIAL. NO MATERIAL SHALL BE ORDERED BY MANUFACTURER AND CATALOG NUMBER ONLY. EACH CONTRACTOR SHALL FIRST READ THE COMPLETE DESCRIPTION OF THE MATERIAL ON THESE DRAWINGS AND SPECIFICATIONS.

THE FIRST MANUFACTURER LISTED IS THE BASIS OF DESIGN. "STANDARD COLOR" INDICATES FACTORY FINISH AVAILABLE AT NO ADDITIONAL CHARGE.

GENERAL TECHNOLOGY EQUIPMENT SCHEDULE

EQUIPMENT LIST

ABBREVIATION EQUIPMENT LIST DESCRIPTION

EQUIPMENT LIST

MANUFACTURER AND MODEL

AC-CR1-W CARD READER. PROVIDED AS INTEGRAL PART OF SECURITY MANAGEMENT SYSTEM. REFER TO CONTROLLED SECURITY SCHEME (CSS) TYPE SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION. CARD READERS SHOWN ON PLANS TO IDENTIFY INTENDED MOUNTING LOCATION. REFER TO SPECIFICATION SECTION 28 13 00 FOR COMPLETE INFORMATION.

IDENTIV

uTRUST SCRAMBLEPAD

AC-DR-S ACCESS CONTROL DURESS/PANIC BUTTON, SURFACE MOUNT. INVONICS

EN1235D

AC-DRK-1 WIRELESS HIGH POWER DURESS BUTTON RECIVER/KEYPAD, PROVIDES 2 WAY, SUPERVISED COMMUNICATION USING 900 MHZ FREQUENCY HOPPING SPREAD SPECTRUM, SUPPORTS UP TO 32 WIRELESS ZONES, RECIEVER SHALL PROVIDE AUDIBLE ALARM UPON RECEIPT OF DURESS CONDITION FROM ANY TRANSMITTER. RECEIVER SHALL DISPLAY ORIGINATING ZONE AND NAME INFORMATION OF SIGNALING TRANSMITTER. PROVIDE WITH BLUE LIGHT TO VISUALLY

INDICATE ALARM CONDITION.

ADVANTOR

INFRATOUCH

INNOVONICS

EN4232MR

AC-EDR-W WALL MOUNTED ELECTRIC DOOR SWITCH. MOMENTARY PUSH BUTTON. 1" GUARD RING. CONTACTS RATED AT 4 AMPS AT 28VDC. MOUNT UNDER COUNTER TOP AND PROVIDE ROUGH-IN/PATHWAY AT NEAREST WALL TO ABOVE CEILING FOR ROUTING

OF CABLING.

ASSA ABLOY

TS-18

AC-SCP-1 ACCESS CONTROL SECURITY PANEL, REFER TO SPECIFICATION SECTION 28 13 00 FOR COMPLETE INFORMATION. OWNERS EXISTING SMS WORKSTATION AT THE MONITORING FACILITY SHALL BE USED FOR ADMINISTRATION AND MAINTENANCE.

IDENTIV

HIRSCH MX-8

AV-PRO-1 VIDEO PROJECTOR, 1920X1200 PIXELS RESOLUTION, 16:10 ASPECT RATIO, 5200 LUMENS, 20000:1 CONTRAST RATIO, 20000 HOURS LIFE AT HALF LUMINANCE. 1-CHIP DLP LASER DIODE. (2) HDMI IN, (1) DIGITAL LINK IN, (1) LAN IN, (2) COMPUTER IN, (1) SERIAL IN, (1) DVI-D IN, (2) AUDIO IN, (1) VIDEO IN, (1) VARIABLE AUDIO OUT. DIMENSIONS (WXHXD) : 19 5/8˝ x 6 5/8˝*5 x 19 3/8˝.

AUDIO INPUT, FREQUENCY RESPONSE: 20 HZ - 20 KHZ @ +0.5DB. POWER SUPPLY: INPUT: 100-240 VAC, 50-60 HZ OUTPUT: 24 VDC, 1.25A.

PANASONIC

PT-RZ570

CHRISTIE

AV-PRO-MNT-1 CEILING MOUNTED PROJECTOR MOUNT. POLE MOUNT WITH UNIVERSAL HBU BRACKET, ROLL, PITCH AND YAW ADJUSTMENTS (ROLL: +3°, PITCH: +15°, YAW: 360°), 25 lbs WEIGHT CAPACITY, COMPACT DESIGN, OVERALL DIMENSION(HXWXD) :1.8" x 4.4" x 5.1".

CHIEF

RSMAU

PREMIER

PEERLESS

AV-VPS-1 PROJECTION SCREEN, ELECTRIC 69"(H) X 110"(W) CEILING RECESSED, ELECTRICALLY OPERATED WITH QUICK CONNECT MALE CONNECTOR ON THE MOTOR. TENSIONING SYSTEM PROVIDES AN EXTRA FLAT SURFACE FOR OPTIMUM IMAGE QUALITY WITH HEAVY DUTY ALUMINUM EXTRUDED PLENUM ENCLOSURE. PROVIDE WITH BUILT-IN LOW VOLTAGE MOTOR CONTROL, SILENT

MOTOR OPTION. PROVIDE AND INSTALL ALL CONTROL CABLING AND PROGRAM AS REQUIRED.

PROVIDE WITH HD PROGRESSIVE 0.9 SCREEN MATERIAL.

DA-LITE

TENSIONED ADVANTAGE

ELECTROL

DRAPER

STEWART

AV-WP1-W PASSIVE WALLPLATE, CEILING MOUNT OR WALL MOUNT, (1) 3.5 mm STEREO AUDIO CONNECTOR, (1) VGA, AND (1) HDMI.

INSTALL INFORMATION OUTLET IN A 5" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. INSTALL A (1) 1 1/4" EMT CONDUIT AND (1) 1" EMT CONDUIT TO ABOVE ACCESSIBLE CEILING. CABLE ROUTING FROM CONDUIT STUB TO NEAREST CABLE

TRAY SHALL BE VIA J-HOOK WIRE-WAY, REFER TO 4/T6.1 FOR ADDITIONAL INFORMATION.

CABLE WALLPLATES TOGETHER WITH USB, VGA, HDMI CABLE AND SHIELDED AUDIO CABLE. USED TO CONNECT PERSONAL COMPUTER VIDEO AND AUDIO (IF REQUIRED) TO DISPLAY DEVICE. REFER TO 5/T5.1 FOR CONNECTION DIAGRAM.

C2G

PN 39707

NC-D-W NURSE CALL SINGLE COMPARTMENT DOME LIGHT, WALL MOUNT ABOVE DOOR. REFER TO SPECIFICATION SECTION 27 52 23. SIMPLEX

EZ CARE

WEST-COM

NC-NCP-1 NURSE CALL CONTROL PANEL, WALL MOUNT. REFER TO SPECIFICATION SECTION 27 52 23 AND 2/T5.1 FOR RISER DIAGRAM. SIMPLEX

EZ CARE

WEST-COM

NC-ND1-W NURSE CALL MASTER STATION. DESK MOUNT. MICROPROCESSOR BASED WITH VISUAL AND AUDIBLE INDICATION OF PATIENT, NURSE ASSIST, STAFF ASSIST AND ALL EMERGENCY CALLS. REFER TO SPECIFICATION SECTION 27 52 23.

SIMPLEX

EZ CARE

WEST-COM

NC-ND2-W NURSE CALL PULL CORD INITIATION STATION WITH TONE AND VISUAL INDICATION FROM MASTER STATION ND1. REFER TO

SPECIFICATION SECTION 27 52 23.

SIMPLEX

EZ CARE

WEST-COM

SC-CT-1 CABLE TRAY, WIRE MESH TYPE, 4" LOADING DEPTH, 12" WIDTH, COMPLETE WITH ALL FITTINGS AND MOUNTING HARDWARE.

PROVIDE TRAPEZE SUPPORT WITH PLASTIC RETAINER. CUTTING OF THE MESH CABLE TRAY SHALL BE DONE WITH OFFSET BOLT CUTTERS ONLY. 10' MAXIMUM SUPPORT SPAN. EITHER SPLICE WASHERS OR TERMINAL GROUND SUPPORT AND JUMPER WIRE SHALL BE USED TO ATTAIN GROUNDING CONTINUITY THROUGHOUT. Z-BRACKETS SHALL BE USED FOR WALL MOUNTED APPLICATIONS. REFER TO MANUFACTURERS INSTALLATION INSTRUCTIONS AND SPECIFICATION SECTION 27 05 28 FOR

ADDITIONAL INFORMATION.

COOPER B-LINE

FLEXTRAY FT 4x12x10

MONO-SYSTEMS

CABLOFIL

SC-ER-1 EQUIPMENT RACK, 84" HIGH, STANDARD 19" MOUNTING SPACE, 4" WIDE x 6" DEEP UPRIGHTS FEATURING PASS-THRU HOLES ON FRONT AND SIDES FOR CABLE MANAGEMENT. PROVIDE TWO PER RACK, MODULAR D-RINGS ON FRONT OF VERTICAL ORGANIZERS. TOP CENTER WATERFALL, TOP CHANNEL PATHWAY FOR LADDER RACK, PROVIDES (45) 1.75" MOUNTING SPACES.

CHATSWORTH

46353-703

ORTRONICS

HOMACO INC.

HUBBELL

SC-FDC-1 OPTICAL FIBER DISTRIBUTION CABINET, HIGH DENSITY, MINIMUM 24 FIBER CAPACITY, PROVIDE WITH CLAMP AND GROUNDING KIT, COUPLING PANELS, LC CONNECTORS, COUPLINGS AND JUMPERS. REQUIRES (2) 1.75" MOUNTING SPACES. PROVIDE

HARDWARE TO MOUNT (1) SC-FDC-1 IN SC-ER-1 AND (1) SC-FDC-1 ON THE WALL.

CORNING

CCH

ORTRONICS

THE SIEMON COMPANY

SYSTIMAX COMPANY

SC-GND-1 WALL MOUNT GROUND BAR. 4" H X 12" L X 1/4" D COPPER, ELECTRICALLY ISOLATED BY INSULATIOS INTEGRAL TO MOUNTING BRACKETS. PROVIDE UNIT CONFIGURED WITH SIXTEEN (16) SETS OF 5/16" HOLES SPACED 5/8" ON CENTER TO ACCOMMODATE "A" SPACED TWO-HOLE COMPRESSION LUGS AND THREE (3) SETS OF 7/16" HOLES SPACED 1" ON CENTER TO ACCOMMODATE "C" SPACED TWO-HOLE COMPRESSION LUGS. ANSI/EIA/TIA-607 AND BICSI COMPLIANT. UL LISTED. REFER TO 1/T6.1 FOR

ADDITIONAL INFORMATION.

CHATSWORTH PRODUCTS

40153-012

PANDUIT

ERICO

HARGER

SC-HWM-1 HORIZONTAL WIRE MANAGEMENT, SINGLE-SIDED, 3.5"H x 19" W x 8.2" D, PROVIDE WITH COVER. REQUIRES (2) 1.75" MOUNTING

SPACE.

CHATSWORTH

35441-702

ORTRONICS

SYSTIMAX

SC-IO-C INFORMATION OUTLET, SURFACE MOUNT, 2-PORT AS INDICATED ON DRAWINGS AND INFORMATION OUTLET SCHEDULE. REFER

TO INFORMATION OUTLET SCHEDULE ON T7.1 FOR PIN CONFIGURATION INFORMATION.

" # " INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE DRAWINGS. REFER TO INFORMATION

OUTLET SCHEDULE ON T7.1 FOR ADDITIONAL INFORMATION.

INSTALL INFORMATION OUTLET IN A 4" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. MOUNT TO CLOSEST STRUCTURE ELEMENTS (EX. COLUMN). INSTALL A DELUXE CORD GRIP FOR STRAIN RELIEF ON UTP CABLE. PROVIDE 20' COIL OF UTP CABLE AT WIRELESS OUTLET LOCATION. INSTALL A 1 1/4" EMT CONDUIT 6" BEYOND BOX AND TERMINATE WITH NYLON BUSHING. PROVIDE REMOVABLE BLANK INSERTS FOR UNUSED PORTS. ROUTE CABLE TO NEAREST CABLE TRAY VIA J-HOOK

WIREWAY.

COVERPLATE:

HUBBELL

IBS2 SERIES

JACK(CAT 6):

HXJ6 SERIES

BELDEN/CDT

SYSTIMAX

SIEMON

HUBBELL/MOHAWK

BERK-TEK ORTRONICS

MOLEX

LEVITON NEXTLAN

PANDUIT

SC-IO-F INFORMATION OUTLET, FLOORBOX OR POKE-THROUGH MOUNT, 4-PORT COVERPLATE AS INDICATED ON DRAWINGS, REFER TO

INFORMATION OUTLET SCHEDULE ON SHEET T7.1 FOR PIN CONFIGURATION.

" # " INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE PLANS. REFER TO INFORMATION

OUTLET SCHEDULE.

INSTALL INFORMATION OUTLET IN E.C. PROVIDED FLOORBOX. PROVIDE ADAPTER PLATE FOR 106-TYPE FACEPLATE WHERE REQUIRED. COORDINATE ADDITIONAL MOUNTING REQUIREMENTS WITH E.C. PROVIDE REMOVABLE BLANK INSERTS FOR UNUSED PORTS (PANDUIT CMB OR APPROVED EQUAL). ROUTE CONDUIT TO NEAREST STUD WALL AND ROUTE TO ABOVE

ACCESSIBLE CEILING.

REFER TO ELECTRICAL SPECIFICATION FOR FLOORBOX AND ROUGH-IN DESCRIPTION.

CABLE ROUTING FROM CONDUIT STUB TO NEAREST CABLE TRAY SHALL BE VIA J HOOK WIREWAY, REFER TO 4/T6.1 FOR

ADDITIONAL INFORMATION.

COVERPLATE:

HUBBELL

IPF SERIES

JACK(CAT 6):

HXJ6 SERIES

F-CONNECTOR:

SFF SERIES

BELDEN/CDT

SYSTIMAX

SIEMON

HUBBELL/MOHAWK

BERK-TEK ORTRONICS

MOLEX

LEVITON NEXTLAN

PANDUIT

SC-IO-W INFORMATION OUTLET, ANGLED WALL MOUNT, 1, 2 OR 4-PORT COVERPLATE AS INDICATED ON DRAWINGS, REFER TO

INFORMATION OUTLET SCHEDULE ON SHEET T7.1 FOR PIN CONFIGURATION.

" # " INDICATES INFORMATION OUTLET FACEPLATE CONFIGURATION AS INDICATED ON THE PLANS. REFER TO INFORMATION

OUTLET SCHEDULE ON T7.1.

" TV "INDICATES TELEVISION SERVICE OUTLET. CABLE OUTLET WITH RATED RG-6, 75 OHM COAX CABLE. TERMINATE ON F-STYLE

CONNECTOR. INSTALL IN 1-PORT COVER PLATE.

INSTALL INFORMATION OUTLET IN A 5" SQUARE BACKBOX WITH A SINGLE GANG PLASTER RING. INSTALL A 1 1/4" EMT CONDUIT TO ABOVE ACCESSIBLE CEILING. CABLE ROUTING FROM CONDUIT STUB TO NEAREST CABLE TRAY SHALL BE VIA J-HOOK

WIREWAY, REFER TO 4/T6.1 FOR ADDITIONAL INFORMATION.

COVERPLATE:

HUBBELL

AFP SERIES

JACK(CAT 6):

HXJ6 SERIES

F-CONNECTOR:

SFF SERIES

BELDEN/CDT

SYSTIMAX

SIEMON

HUBBELL/MOHAWK

BERK-TEK ORTRONICS

MOLEX

LEVITON NEXTLAN

PANDUIT

SC-LR-1 LADDER RACK, 12" W TUBULAR STEEL CONSTRUCTION, RUST RESISTANT ENAMEL FINISH, GRAY IN COLOR. REMOVE SHARP BURRS FROM LADDER RACK AND REPAINT ALL AREAS THAT HAVE BEEN FIELD MODIFIED, CUT OR EXPOSED. U.L. LISTED.

CHATSWORTH

10250-112

HUBBELL

MONO-SYSTEMS

CABLOFIL

SC-MPP-1 MODULAR PATCH PANEL, 48 MODULAR RJ-45 TERMINATIONS, MOUNTS DIRECTLY TO EIA/TIA STANDARD 19" RELAY RACK, PORT IDENTIFICATION NUMBERS, PROVIDED WITH COLOR CODING AND LABEL HOLDER KITS, U.L. LISTED. REQUIRES (2) 1.75"

MOUNTING SPACES.

HUBBELL

HP648 SERIES

BELDEN/CDT

SYSTIMAX

SIEMON

HUBBELL/MOHAWK

BERK-TEK ORTRONICS

MOLEX

LEVITON NEXTLAN

PANDUIT

SC-RI-W TECHNOLOGY ROUGH-IN, FLUSH MOUNT ON WALL OR AS NOTED IN PLANS, ALL TECHNOLOGY ROUGH-INS SHALL HAVE (1) 4" SQUARE BACKBOX WITH SINGLE GANG PLASTER RING, APPROPRIATE…