Attachment 4 - Drawings 08 Fire Alarm.pdf
PDF 750 KB Posted
- Attached to
- Eglin NICoE Initial Outfitting Project
- Solicitation number
- W9127S20Q6000
About this file
This is a combined synopsis and solicitation for a construction project. The U.S. Army Corps of Engineers seeks to outfit the Eglin Neuroscience Center of Excellence Initial Outfitting Project at Eglin Air Force Base in Florida. Interested Service-Disabled Veteran-Owned Small Businesses must submit quotes by January 8th for work including mechanical, electrical, and fire protection systems. A site visit is scheduled for December 4th, and notice of intent to attend is due by November 29th. The NAICS code is 337127 and size standard is 500 employees. This procurement will follow simplified acquisition procedures under FAR Part 13 for commercial items under FAR Part 12.
The solicitation provides contact information for the site visit and requests contractor data for base access. Additional details on entrance to the base will be provided to confirmed attendees. The document and incorporated provisions and clauses reflect updates from Federal Acquisition Circular 2019-06.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
LOW VOLTAGE (BELOW 50 VOLTS)
L-L L-N
LTG
LV
LIGHTING
LINE TO LINE
LINE TO NEUTRAL
1000 CIRCULAR mils
KILOVOLTS (THOUSAND VOLTS)
KILOWATTS (THOUSAND WATTS)
LIGHTNING ARRESTOR
LOCAL AREA NETWORK
KILOVOLTS-AMPERES (THOUSAND VOLT-AMPS)
ISOLATED GROUND
KWH
LAN
LA
KW
KVA
Kcmil
KV
KILOWATT-HOURS
INCAND
KEY INTERLOCK
JUNCTION BOX
INCH/INCHES (")
INCANDESCENT
GROUND FAULT INTERRUPTER
HAND-OFF-AUTOMATIC
HIGH PRESSURE SODIUM
HEATING VENTILATION AND AIR CONDITIONING
HERTZ
HVAC
HZ
HTR
HR
HT
HPS
HOA
HP
HEATER
HEIGHT
HORSEPOWER
HOUR
GFI
G, GND, GRD
GEN
FLUOR
FL, FLR
GROUND
GENERATOR
FOOT/FEET (')
FLUORESCENT
FLOOR
CATV
ELECTRIC WATER COOLER
ELECTRIC WATER HEATER
FIRE ALARM ANNUNCIATOR PANEL
ELECTRIC, ELECTRICAL
ELECTRIC METALLIC CONDUIT
EQUIPMENT GROUND
EWC
FAAP
FLA
FDR
EWH
FA
FULL LOAD AMPS
FEEDER
FIRE ALARM
FUSE
ELEC
EQ, EQUIP
EM, EMERG
EMT
ELEV
ENCL
EG
EQUIPMENT
ELEVATOR
EMERGENCY
ENCLOSURE
DISTRIBUTION PANEL
DOUBLE POLE SINGLE THROW
DOUBLE POLE DOUBLE THROW
CONTROL POWER TRANSFORMER
CURRENT TRANSFORMER
DPDT
DWG
DPST
DIST
DISC
DC
DP
DN
DRAWING
DISTRIBUTION
DIRECT CURRENT
DISCONNECT
DOWN
CPT
CU
CT
COM, COMM
CKT
CLG
COPPER
COMMUNICATIONS
CIRCUIT
CEILING
CABLE TELEVISION
AMERICAN WIRE GAUGE
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AUTOMATIC TRANSFER SWITCH
AMPERE INTERRUPTING CAPACITY
ALTERNATING CURRENT
ABOVE FINISHED COUNTER
AWG
CB
BLDG
BRKR, BKR
CIRCUIT BREAKER
CONDUIT
BUILDING
BREAKER
AUTO
AUX
ARCH
AT
ATS
ALT
AFG
AIC
AFC
AFF
AC
AF
AUXILIARY
ALTERNATE
ARCHITECT
AUTOMATIC
AMPERES TRIP
AMPERE FRAME (BREAKER RATING)
MTG
MV
MH
MOCP
MTD
MLO
MIN
MISC
MECH
MCC
MFR
MCA
MCB
MOUNTING
MEDIUM VOLTAGE (OVER 600V LESS THAN 35KV)
MINIMUM CIRCUIT AMPACITY
MAIN CIRCUIT BREAKER
MOTOR CONTROL CENTER
MAXIMUM OVERCURRENT PROTECTION
MOUNTED
MISCELLANEOUS
MAIN LUGS ONLY
MINIMUM
MANHOLE
MANUFACTURER
MECHANICAL
FIRE ALARM CONTROL PANELFACP
FIRE ALARM EXTENDER PANELFAEP
AIR HANDLING UNITAHU
CCTV CLOSED CIRCUIT TELEVISION
CP CONTROL PANEL
FLEX FLEXIBLE
HAND HOLEHH
LIGHTING CONTROL PANELLC, LCP
LIGHTING PANEL
L-G LINE TO GROUND
MTS MANUAL TRANSFER SWITCH
AMPERESA
C
F
EXISTINGE, EX, EXIST
FT
IN
IG
JB, JBOX
K
LP
FOOT CANDELFC
DIV DIVISION
FIRE ALARM ABBREVIATIONS
A M
B
C
D
E
F
G
H
I
J
K
L
N
NO., NUM, #
NTS
NC
NEMA
NO
NIC
NEC
N
NOT TO SCALE
NUMBER
NATIONAL ELECTRICAL MANUFACTURERS
ASSOCIATION
NORMALLY CLOSED
NORMALLY OPEN
NOT IN CONTRACT
NEUTRAL
NATIONAL ELECTRIC
CODE
O
OCPD
OC
OVERCURRENT PROTECTION DEVICE
ON CENTER
OPP
OHE/T
OH
OFOI
OFCI
OPPOSITE
OWNER FURNISHED, CONTRACTOR INSTALLED
OWNER FURNISHED, OWNER INSTALLED
OVERHEAD ELECTRIC/TELEPHONE
OVERHEAD
P
PRI
PWR
PT
PVC
PA
PH, ∅
PF
PNL
PE
PB
P
POTENTIAL TRANSFORMER
POLYVINYL CHLORIDE
POWER
PUBLIC ADDRESS
PANEL
PRIMARY
PULL BOX
POWER FACTOR
PHOTO ELECTRIC
PHASE
POLE
PDP POWER DISTRIBUTION PANEL
Q
QTY QUANTITY
R
RCLP
RM
RP
REF
RCPT
RSC
RLA
RF
R, RE
RIGID STEEL CONDUIT
RATED (RUNNING) LOAD AMPS
RECEPTACLE PANELBOARD
ROOM
RADIO FREQUENCY
RECEPTACLE
REFRIGERATOR
RELOCATE AS SHOWN
REMOTE CONTROL LIGHTING PANEL
S
SPST
SWBD
SYM
STD
SW
SPEC(S)
SPDT
SPKR
SF
SEC
SINGLE POLE SINGLE THROW
SINGLE POLE DOUBLE THROW
SYMMETRICAL
SWITCHBOARD
STANDARD
SWITCH
SECONDARY
SQUARE FOOT
SPECIFICATION(S)
SPEAKER
SCH, SCHED SCHEDULE
SWGR SWITCHGEAR
T
TYP
TV
TP
TEL,TELE
TELECOM
TC
TELECOMMUNICATIONS
TYPICAL
TELEVISION
TAMPERPROOF
TIME CLOCK
TELEPHONE
TB TERMINAL BLOCK
TBB TELEPHONE BACKBOARD
U
UPS
UL
UON
UG
UGS
UGT
UGP UNDERGROUND PRIMARY
UNDERGROUND SECONDARY
UNDERGROUND TELEPHONE
UNDERWRITER'S LABORATORY
UNLESS OTHERWISE NOTED
UNINTERRUPTIBLE POWER SUPPLY
UNDERGROUND
V
VFD
VA
V VOLTS
VARIABLE FREQUENCY DRIVE
VOLT-AMPERES
W
WP
WHM
W/ W/O
W
WATT HOUR METER
WEATHERPROOF
WITHOUT
WITH
WIRE
X X
XFMR TRANSFORMER
REMOVE DEVICE
Z
% Z PERCENT IMPEDANCE
FIRE ALARM SYMBOLS GENERAL NOTES
A.
B.
C.
D.
E.
F.
G.
H.
I.
J.
K.
L.
M.
N.
O.
P.
Q.
R.
S.
T.
U.
V.
W.
X.
Y.
Z.
J J JUNCTION BOX (RECESSED/SURFACE) FOR FIRE ALARM SYSTEMS PLANS.
F
SD
BT/BR
TS
WF
AP
DH
PS
FACP
FAAP
FACP
FAAP
EVAC
MAGNETIC DOOR HOLD OPEN DEVICE
HI / LOW AIR PRESSURE SWITCH, FOR CONNECTION ONLY
VALVE SUPERVISORY (TAMPER) SWITCH, FOR CONNECTION ONLY
WATER FLOW SWITCH, FOR CONNECTION ONLY
CARBON MONOXIDE DETECTOR
SMOKE DETECTOR FOR ELEVATOR RECALL
SMOKE DETECTOR FOR ACTIVATION OF SMOKE DAMPER, FOR CONNECTION ONLY
SMOKE DETECTOR - CEILING OR SURFACE MOUNTED
ALARM PRESSURE SWITCH, FOR CONNECTION ONLY
NOTIFICATION APPLIANCE POWER EXTENDER PANEL
STROBE - WALL MOUNTED
STROBE - CEILING MOUNTED
FIRE FIGHTER'S TELEPHONE
FIRE ALARM ANNUNCIATOR PANEL AND LOCAL OPERATING CONSOLE (FLUSH/SURFACE)
FIRE ALARM REMOTE CONTROL PANEL (FLUSH/SURFACE)
MANUAL FIRE ALARM PULL STATION
VOICE EVACUATION PANEL
FA/MASS NOTIFICATION SPEAKER WITH STROBE - WALL MOUNTED
FA/MASS NOTIFICATION SPEAKER - WALL MOUNTED
FA/MASS NOTIFICATION SPEAKER WITH STROBE - CEILING MOUNTED
FARPFARP FIRE ALARM SYSTEM CONTROL PANEL (FLUSH/SURFACE)
DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER
FI FAULT ISOLATION MODULE
SPD SURGE PROTECTIVE DEVICE
NAC
PB
EN
ELECTRICAL PULL BOX, FOR CONNECTION ONLY
NEMA 1 ENCLOSURE CABINET
GF GENERATOR FAULT CONNECTION
GR GENERATOR RUNNING CONNECTION
WHERE ANY CONFLICT AND/OR DISCREPANCY BETWEEN THESE GENERAL NOTES AND ANY OTHER INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS EXISTS, THE MORE STRINGENT REQUIREMENT SHALL PREVAIL AND BE A REQUIREMENT OF THE WORK. THAT NOTWITHSTANDING, ANY SUCH CONFLICT AND/OR DISCREPANCY SHALL PROMPTLY BE BROUGHT TO THE ATTENTION OF THE OWNER, ARCHITECT AND ENGINEER
THE WORK INCLUDES, BUT IS NOT LIMITED TO DESIGNING AND PROVIDING A COMPLETELY SUPERVISED, MULTIPLEXED, INTELLIGENT, ANALOG, ADDRESSABLE COMBINED FIRE ALARM AND DETECTION/MASS NOTIFICATION SYSTEM. THE WORK SHALL INCLUDE, BUT NOT BE LIMITED TO, ALL WIRING, RACEWAYS, PULL BOXES, TERMINAL CABINETS, OUTLET AND MOUNTING BOXES, CONTROL EQUIPMENT, ALARM AND SUPERVISORY SIGNALS, INITIATING DEVICES, ALARM NOTIFICATION APPLIANCES, NOTIFICATION ALARM PANELS, INTERFACE EQUIPMENT, AND ALL OTHER ACCESSORIES AND MISCELLANEOUS ITEMS INCLUDING SOFTWARE, SYSTEM PROGRAMMING, TEST AND CONSTRUCTION PERMITS REQUIRED FOR A COMPLETE OPERATING SYSTEM NORMALLY AND CUSTOMARILY REQUIRED, WHETHER INDICATED OR INHERENTLY NECESSARY DUE TO THE NATURE OF THE WORK. THE WORK SHALL BE LISTED FOR THE INTENDED PURPOSE BY A NATIONAL RECOGNIZED TESTING LABORATORY.
ALL WORK SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THE EGLIN AIR FORCE BASE ENGINEERING DESIGN MANUAL, AMENDED CODE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION, UFC 3-600-01, UFC 4-021-01, AND THE
REFERENCED EDITIONS OF NFPA 13, 14, 20, 70 AND 72 .
THE TERM "PROVIDE" SHALL MEAN FURNISH, INSTALL AND CONNECT EQUIPMENT/DEVICE FOR A COMPLETE AND OPERATIONAL SYSTEM.
PROVIDE ALL NECESSARY PERMITS, INSPECTIONS AND FINAL SYSTEM ACCEPTANCE FROM THE AUTHORITY HAVING JURISDICTION (AHJ).
COORDINATE ALL WORK AND AVOID ALL CONFLICTS WITH LIGHTING FIXTURES, DIFFUSERS, GRILLS, DUCTS, STRUCTURAL MEMBERS, PIPES AND OTHER OBSTRUCTIONS
ALL FIRE ALARM CIRCUITS SHALL BE SUPERVISED AS FOLLOWS DETAILED IN SPECIFICATION IN ACCORDANCE WITH EGLIN DESIGN MANUAL.
SUBJECT TO ANY INFORMATION CONTAINED IN THE CONTRACT DOCUMENTS, MOUNT ALL VISUAL WARNING STROBE/AUDIBLE NOTIFICATION APPLIANCES TO ACHIEVE MAXIMUM AUDIBILITY AND VISIBILITY IN ACCORDANCE WITH CURRENT ADAAG GUIDELINES.
PROVIDE CARE IN LOCATING VISUAL WARNING STROBE APPLIANCES TO INSURE VISIBILITY AND AVOID OBSTRUCTIONS. PROVIDE MINIMUM INTELLIGIBLITY CRITERIA THROUGHOUT THE BUILDING IN ACCORDANCE WITH CHAPTER 24.
SUBJECT TO ANY CODE RESTRICTION AND/OR REQUIREMENT; PROVIDE ELECTRICAL METALLIC TUBING (EMT), UNLESS OTHERWISE NOTED.
IN AREAS WITHOUT CEILINGS, CONDUIT SHALL BE INSTALLED AS UNOBTRUSIVELY AS POSSIBLE, AS CLOSE AS POSSIBLE TO FLOOR/CEILING SLAB AND PARALLEL AND AT RIGHT ANGLES TO STRUCTURAL STEEL OR CONCRETE.
CONCEAL ALL CONDUIT ABOVE SUSPENDED CEILINGS AND BEHIND WALLS. CONDUIT MAY BE SURFACE MOUNTED IN UNFINISHED AREAS , UNLESS OTHERWISE NOTED.
EXPOSED CONDUIT SHALL BE PAINTED TO MATCH ADJACENT FINISH.
COORDINATE LOCATION OF AUTOMATIC SPRINKLER FLOW AND VALVE SUPERVISORY SWITCHES PRIOR TO CONDUIT ROUGH-IN TO ENSURE ACCESSIBILITY AND MINIMIZE LENGTH OF FLEXIBLE CONDUIT RUNS NECESSARY TO MAKE CONNECTIONS.
ALL WALL AND FLOOR PENETRATIONS SHALL BE CORE-DRILLED WITH MASONRY TYPE CORE BIT. AFTER CONDUIT INSTALLATION, ALL PENETRATIONS IN WALLS, CEILINGS AND FLOORS SHALL BE SEALED TO THE FULL THICKNESS OF THE PENETRATION WITH
APPROVED FIRESTOPPING MATERIAL OF EQUAL OR GREATER FIRE RESISTANCE.
ELECTRICAL BOXES SHALL BE PROVIDED AS FOLLOWS: I) EXPOSED WORK - CAST METAL BELL TYPE BOXES WITH THREADED HUB, EXCEPT WHERE FACTORY BOXES ARE PROVIDED; AND II) CONCEALED WORK - BOXES MAY BE STAMPED STEEL BOXES.
PROVIDE TERMINAL CABINETS OF SOLID WALL CONSTRUCTION WITH NO FACTORY CONDUIT KNOCK OUTS.
PROVIDE COMPRESSION TYPE STEEL FITTINGS AND CONNECTORS FOR BOTH EXPOSED AND CONCEALED CONDUITS INCLUDING RISERS UP TO 2 INCHES IN DIAMETER.
CONDUIT & RISERS: I) PROVIDE ¾ INCH MINIMUM EMT TRADE SIZE CONDUIT, UNLESS OTHERWISE NOTED; II) VERTICAL RISERS SHALL BE ONE INCH DIAMETER EMT MINIMUM.
PROVIDE WIRING CONDUCTORS AS INDICATED BELOW:
INITIATING - NO. 18/2 AWG, TSP
SIGNALING - NO. 18/2 AWG, TSP W/ DRAIN WIRE
NOTIFICATION APPLIANCES - 14/2 AWG
CONTROL - 16/2 AWG
120 VAC POWER - 12/2 AWG, WITH NO 12 AWG E.G., 600 VAC INSULATED
ALL DAMAGE TO WALLS, CEILINGS, FLOORS, AND STRUCTURAL MEMBERS FROM THE WORK SHALL BE PATCHED, REPAIRED AND PAINTED WITH NEW MATERIALS TO MATCH ADJACENT WORK, WHETHER SPECIFICALLY NOTED OR NOT.
LOCATE FIRE ALARM DEVICES INSTALLED IN ACOUSTICAL TILE CEILINGS IN THE CENTER OF THE TILE. MOUNT WALL MOUNTED DEVICES 84 INCHES ABOVE FINISHED FLOOR AT CENTER OF DEVICE. SECONDARY POWER SHALL BE PROVIDED FOR 72 HOURS OF
STANDBY AND 10 MINUTES OF ALARM.
PROVIDE ALL EQUIPMENT IN ACCORDANCE WITH SEISMIC CRITERIA FOUND IN NFPA 72.
FIRE ALARM DEVICES SHALL BE WHITE IN COLOR AND READ 'ALERT' WITH AMBER STROBES (IN VISIBLE NOTIFICATION APPLIANCES).
INSTALL BUILDING TRANSCEIVER TOP OF PANEL ENCLOSURE NO HIGHER THAN 60 INCHES ABOVE FINISHED FLOOR.
INSTALL FIRE ALARM CONTROL PANEL TOP OF PANEL ENCLOSURE NO HIGHER THAN 70 INCHES ABOVE FINISHED FLOOR.
SPEAKERS IN PATIENT-SENSITIVE AREAS INDICATED BY VERTICAL HATCHING ARE TO BE ON DEDICATED CIRCUIT WITH MANUAL ON/OFF BROADCASTING FOR USE BY THE FIRE DEPARTMENT VIA ISOLATED SELECTOR SWITCH AT THE VOICE EVACUATION PANEL. SPEAKERS ON DEDICATED CIRCUIT FOR PATIENT-SENSITIVE AREAS SHALL INITIATE ALL VOICE MESSAGES WITHOUT OUTPUT OF TEMPORAL-THREE ALARM, SYNCHRONIZED WITH OTHER SPEAKER CIRCUIT.SPEAKERS ON DEDICATED CIRCUIT ARE TO
BE TAPPED AT 1/8 WATT IN THESE PATIENT-SENSITIVE AREAS.
FIRE FIGHTER'S TELEPHONE JACK
BATT BATTERY CABINET
FA
FA, FA
REFERENCE SYMBOLS
SECTION NUMBER
DETAIL NUMBER
DRAWING NUMBER WHERE DRAWN
DRAWING NUMBER WHERE DRAWN
E1-1.0
E1-1.0
KEY NOTE
ER
SMOKE DETECTOR FOR RETURN AIR PLENUM APPLICATIONRA
DUCT SMOKE DETECTOR REMOTE TEST STATION
AI FIRE ALARM ADDRESSABLE INTERFACE MODULE (INPUT)
AR FIRE ALARM ADDRESSABLE RELAY (OUTPUT)
FATC FIRE ALARM TERMINAL CABINET
AMP FIRE ALARM AMPLIFIER PANEL
ZONE # FIRE ALARM ZONE IDENTIFICATION NUMBER
FIRE ALARM ZONE BOUNDARY
BT/BR,
SMOKE DETECTOR HVAC DUCT TYPE
RF MONACO BT-XM RADIO FREQUENCY COMMUNICATION TRANSMITTER
LOC LOCAL OPERATING CONSOLE
SMOKE DETECTOR BEAM TYPE
MINIMUM INELIGIBILITY BOUNDARY
FIRE ALARM SEQUENCE OF OPERATIONS
NOTES:
1. THE USE OF THE MICROPHONE SHALL NOT INITIATE ANY SIGNALS UNLESS THE FIRE ALARM SIGNAL HAS BEEN ACTIVATED.
2. PROVIDE THE FOLLOWING MESSAGES AND PROVIDE 5 ADDITIONAL SPACES TO BE PROGRAMED AT A LATER DATE.
3. MASS NOTIFICATION MESSAGES SHALL TAKE PRIORITY AND OVERRIDE FIRE ALARM MESSAGES.
4. CLEAR/WHITE STROBE SHALL NOT ACTIVATE WHEN AMBER STROBES ARE IN OPERATION.
5. SPEAKERS ON DEDICATED CIRCUIT FOR PATIENT-SENSITIVE AREAS (EXAM ROOMS, PROVIDER OFFICES, THERAPY SPACES, ETC.) SHALL INITIATE ALL VOICE MESSAGES WITHOUT TEMPORAL-THREE TONE ALARM, SYNCRONIZED WITH OTHER SPEAKER CIRCUIT. SPEAKERS ON DEDICATED CIRCUIT ARE TO BE TAPPED AT 1/8 WATT IN THESE SENSITIVE AREAS.
ALL CLEAR
PRE-ANNOUNCEMENT SOUND – DING-DONG – PERCUSSIVE PAIRS OF 700 AND 570 HZ TONES EACH DAMPED TO ZERO (ONE CYCLE)
ANNOUNCEMENT: VOICE – DONNA (REPEAT TWO CYCLES) – THE EMERGENCY HAS BEEN RESOLVED; RETURN TO NORMAL OPERATIONS
TEST
RE-TEST SOUND – NOAA STANDARD ALERT TONE - 1050 HZ (8 SECONDS)
ANNOUNCEMENT: VOICE – TOM – TEST, TEST, TEST, THIS IS AN EMERGENCY NOTIFICATION AUDIO SYSTEM TEST; YOU MAY CONTINUE NORMAL OPERATIONS, TEST, TEST, TEST.
FIRE
ALERT SOUND – NFPA TEMPORAL 3 (T-3) - 422-775HZ UPWARD SWEEP OVER 850 MS FOR THREE-PULSES EACH SEPARATED BY 1 SECOND FOLLOWED BY A 1.5 SECOND DELAY (REPEAT 2 CYCLES) A FIRE EMERGENCY HAS OCCURRED; PLEASE LEAVE THE BUILDING BY THE NEAREST EXIT AND REPORT TO YOUR ASSEMBLY LOCATION
FIRE ALARM RISER DIAGRAM
GROUND FLOOR
ROOF
ELECTRICAL CLOSET 114 ELECTRICAL CLOSET 330
FACP
NAC
AMP
SPD
BATT
ACU
FATCFI JJ120 VAC 120 VACSPD
NAC
AMP
FIF
WF
AIAR
AHU
SD
TS
AI
FA/MASS NOTIFICATION SPEAKER - CEILING MOUNTED
WP WP WP
WP
F
RF
ACU AUTONOMOUS CONTROL UNIT
LOC
MAIN VESTIBULE/
SOUTH EXIT
(X2)FACP
PATIENT-SENSITIVE AREAS
DRAWING NUMBER
PROJECT NUMBER
SCALE
DRAWING TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
Cagley & Associates
STRUCTURAL ENGINEERING
6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050
1700 NEW YORK AVE, NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 www.smithgroup.com
Pl ot
D at e:
EGLIN AIR FORCE BASE
BUILDING XX
ASH DR, EGLIN AIR FORCE BASE
FLORIDA
32542
IMEG Corporation
ELECTRONIC SECURITY / TELECOMMUNICATIONS
2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906
Baskerville-Donovan, Inc.
CIVIL ENGINEERING
449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340
SmithGroup
MEP-FP ENGINEERING
1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100
1 : 1
1/ 4/
2:
:2
PM FIRE ALARM
ABBREVIATIONS AND
SYMBOLS
FA0.1
10822.000
13 MASS NOTIFICATION ACTIVE
13 MANUAL MASS NOTIFICATION MESSAGE WHEN FIRE ALARM IS ACTIVATED
12 MANUAL MASS NOTIFICATION MESSAGE
11 NOTIFICATION APPLIANCE CIRCUIT SHORT
10 SLC/INITIATING DEVICE CIRCUIT FAULT
9 GROUND FAULT
8 OPEN CIRCUIT
7 FIRE ALARM SYSTEM LOW BATTERY
6 FIRE ALARM AC POWER FAIL
5 SPRINKLER VALVE SUPERVISORY SWITCH
4 SPRINKLER WATERFLOW SWITCH
3 DUCT MOUNTED SMOKE DETECTOR @ AHU (RETURN) FOR AHUS
2 SMOKE DETECTORS ‐ SPOT TYPE
1 MANUAL PULL STATION
AL
AR
M A N N U N
CI
AT
IO
N
F
AC
P
AN
D
RE
M O
TE
A N N U N
CI
AT
O R
BY
D
EV
IC
E
TR
O U
BL
E
AN
N U N
CI
AT
IO
N
F
AC
P
AN
D
RE
M O
RE
A N N U N
CI
AT
O R
BY
D
EV
IC
E
SU
PE
RV
IS
O
RY
A N N U N
CI
AT
IO
N
F
AC
P
AN
D
RE
M O
TE
A N N U N
CI
AT
O R
PA
N
EL
TR
AN
SM
IT
S
IG
N
AL
T O S U
PE
RV
IS
IN
G S
TA
TI
O N
RE
CO
RD
A N D
PR
IN
T
CH
AN
G E O F
SY
ST
EM
S
ST
AT
U S
AN
N U N
CI
AT
E
AS
SO
CI
AT
ED
IN
FO
RM
AT
IO
N O N A
LL
R
EM
O
TE
F
AA
CP
S
BR
O
AD
CA
ST
P
RE
‐R
EC
O
RD
ED
F
IR
E
AL
AR
M E M
ER
G
EN
CY
E
VA
CT
U
AT
IO
N M
ES
SA
G E
TH
RO
U G H
AU
DI
BL
E
SP
EA
KE
RS
AC
TI
VA
TE
C
LE
AR
(A
LE
RT
) V
IS
IB
LE
N O
TI
FI
CA
TI
O N D
EV
IC
ES
SH
U T‐
DO
W N O N
LY
T
HE
A
SS
O
CI
AT
ED
A
HU
A N D
IN
DI
CA
TE
A T
RE
M O
TE
S
TA
TI
O N
M U
TE
A
LL
P U
BL
IC
A
DD
RE
SS
/S O U N D
SY
ST
EM
S
IN
IT
IA
TE
S
EC
U
RI
TY
L O
CK
R
EL
EA
SE
BR
O
AD
CA
ST
M
AS
S N O
TI
FI
CA
TI
O N M
ES
SA
G E
TH
RO
U G H
AU
DI
BL
E
SP
EA
KE
RS
AC
TI
VA
TE
A M
BE
R
VI
SI
BL
E N O
TI
FI
CA
TI
O N D
EV
IC
ES
SYSTEM INPUT SY
ST
EM
O U
TP
U T
A B C D E F G H I J K L M
SCHEMATIC DESIGN 8.17.2018
DESIGN DEVELOPMENT 11.08.2018
CONTRACT DOCUMENTS 01.04.2019
DA
CT
FA
CP
NA
C
AM
P
BA
TT
SP
D
J
AC
U
F
NA
C
AM
P
SP
D
J
F
F
F
FI
FA
TC
AR
AR
F
F
F
AI AI
WF TS
F
FI
LOC
LCD
LO
C
RF
AR
0.7A
0.9A
A.9
A.7
15 15
FA
1515 15
FA209
FA209
FA209
FA209
FA203
FA215
FA207
FA203
FA208
FA215
B2
E.8
FA209
FA209
FA211
FA211
FA218
FA209FA209
FA209
FA
TLT/ SHR
218.2
CHANGING / LOCKER (M)
CHANGING / LOCKER (W)
VESTIBULE
MECHANICAL
ELEC
SOIL UTIL
COMM
PUBLIC WAITING
C101
WORKSTATION PT
PT GYM
CORRIDOR
C300
CORR
C200
TLT/ SHR
218.1
CORR
C302
CORR
C305
CORR
C304
CORR
C306
CORR
C303
CORR
C301
CORR
C201
MAT / PLATFORM
EQPT STOR
CLEAN UTIL
NEURO REHAB AREA
CORR
C102.1
FAMILY WAITING
CENTRAL PARK
MAIN CORRIDOR / LOBBY
C100
PAT TLT
ELEC
COMM
NP PSYCH
BH / SW PROVIDERS
BH / SW PROVIDERS
STAFF LOUNGE
MUSIC THERAPY
RECEPTION
PTNT INTAKE CUBICLES
300.1
MALE TOILET
FEMALE TOILET
HOUSEKEEPING
DAILY LIVING SKILLS
RESEARCH SHARED OFFICE
NCOIC / ADMIN
NICoE DIR.
DIR. OF OPERATIONS
112AV SUPPLY
CLASSROOM
103.1
FA206
FA218FA222
FA216
FA219
PSYCHOLOGIST
BH / SW PROVIDER
STAFF TLT
GROUP THERAPY
335.1
GROUP THERAPY
TRANS-CRANIAL MAGNETIC STIM
BIO NEUROFEEDBACK
CASE MGMT
EXAM
350 NUTRITIONIST
352SOIL UTIL
HOUSEKEEPING
STAFF TLT
318 EXAM
349 EYE TESTING
TREATMENT IPMC
EYE LANE
TRAZER / FATS
OT O/E
213 SPEECH THERAPY - OFFICE
SPEECH THERAPY - TESTING
PT O/E
208PT O/E
MULTI-STATION TREATMENT RM
STORAGE / ALCOVE
200.1
DAYROOM
VENDING ALCOVE
106.1
BREAK ALCOVE
105.1
CASE MGMT
NEUROLOGIST
PC MD
CLINICAL PHARMACIST
CASE MGMT
PAIN MD
CHIRO TREATMENT
CHIRO TREATMENT
EXAM
EXAM
EXAM
EXAM
345EXAM
EXAM
348 TEAM ROOM
304 SPIRITUAL COUNSELLING
CHAPLAIN
SCALE
C306.1
FLEX STORAGE
PAT TLT
STORAGE / KILN
338.1
ART AND CLAY THERAPY
PSYCH TECH
PSYCH TECH
NEUROPSYCH
EQPT STOR
BRAIN LAB
ACUPUNCTURE
341.2
ACUPUNCTURE
341.1
OT O/E
FA209
FA219
ALCOVE / STORAGE
C303.1
GAIT OBS LANE
CORR
C102
TLT / SHR
219.1
123456789
B
C
D
E
F
A
0.4A
A.7
A.2
6.2 5.46.97.1 6.5 4.5 3.3 2.8
0.5A
0.2A
D.7
5.2
0.3A
8.6 8.3 6.8 6.4
4.8
A.9
0.7A
0.9A
B.2
E.8
FA207
FA22515
FA225
FA204
FA205
FA226
CLASSROOM
DRAWING NUMBER
PROJECT NUMBER
SCALE
DRAWING TITLE
KEYPLAN
SEALS AND SIGNATURES
ISSUED FOR REV DATE
PLAN
NORTH
Cagley & Associates
STRUCTURAL ENGINEERING
6141 Executive Boulevard Rockville, Maryland 20852 301.881.9050
1700 NEW YORK AVE, NW
SUITE 100
WASHINGTON, DC 20006
202.842.2100 www.smithgroup.com
Pl ot
D at e:
EGLIN AIR FORCE BASE
BUILDING XX
ASH DR, EGLIN AIR FORCE BASE
FLORIDA
32542
IMEG Corporation
ELECTRONIC SECURITY / TELECOMMUNICATIONS
2882 106th Street Suite 100 Des Moines, Iowa 50322 515.334.9906
Baskerville-Donovan, Inc.
CIVIL ENGINEERING
449 W Main Street Pensacola, Florida 32502 850.438.9661 Engineering Business: EB-0000340
SmithGroup
MEP-FP ENGINEERING
1700 New York Ave, Suite 100 Washington, D.C. 20006 202.842.2100
1/8" = 1'-0"
1/ 4/
2:
:2
PM GROUND FLOOR FIRE
ALARM SYSTEMS
PLAN
FA2.1
10822.000
KEYED NOTES
SHEET NOTES
A. SEE FA0.1 FOR FIRE ALARM AND DETECTION ABBREVIATIONS,
SYMBOLS, AND GENERAL NOTES.
B. SPEAKERS IN AREAS INDICATED BY VERTICAL HATCHING ARE
TO BE ON DEDICATED CIRCUIT WITH MANUAL ON/OFF
BROADCASTING BY FIRE DEPARTMENT VIA ISOLATED
SELECTOR SWITCH AT THE VOICE EVACUATION PANEL. THESE
SPEAKERS SHALL SKIP INITIAL TEMPORAL-THREE ALARM AND
INTIATE NOTIFICATION WITH START OF VOICE MESSAGE.
SPEAKERS ON SEPARATE CIRCUIT ARE TO BE TAPPED AT
LOWEST WATTAGE.
FA203 PROVIDE NEW NOTIFICATION APPLIANCE
POWER EXTENDER (NAC) PANEL AND
AMPLIFIER (AMP) PANEL TO POWER FIRE
ALARM DEVICES.
FA204 PROVIDE NEW FIRE ALARM ANNUNCIATOR
PANEL (LCD TYPE) AND LOCAL OPERATING
CONSOLE (LOC) IN ENTRANCE VESTIBULE.
FA205 PROVIDE AND INSTALL NEW LOCAL
OPERATING CONSOLE (LOC) FOR
OPERATION OF BUILDING MASS
NOTIFICATION SYSTEM.
FA206 PROVIDE AND INSTALL NEW ADDRESSABLE
INTERFACE MODULE TO MONITOR VALVE
SUPERVISORY SWITCH.
FA207 PROVIDE AND INSTALL NEW COMBINATION
VOICE EVACUATION FIRE ALARM CONTROL
PANEL (FACP) AND AUTONOMOUS CONTROL
UNIT (ACU) FOR FIRE ALARM AND MASS
NOTIFICATION THROUGH OUT BUILDING IN
ELECTRICAL ROOM. FIRE ALARM SYSTEM
SHALL BE A SIMPLEX SYSTEM.
FA208 PROVIDE A DIGITAL ALARM COMMUNICATOR
TRANSMITTER.
FA209 PROVIDE NEW WEATHERPROOF DEVICE.
FA211 PROVIDE AND INSTALL NEW ADDRESSABLE
RELAY FOR AUTOMATIC SHUT DOWN OF
AHU MOTOR UPON ACTIVATION OF
ASSOCIATED SMOKE DETECTOR WITHIN 36
INCHES OF AHU CONTROL CIRCUIT.
PROVIDE REMOTE TEST STATION
INDICATING LIGHT. REFER TO MECHANICAL
PLANS FOR EXACT LOCATION OF AHU.
FA215 PROVIDE AND INSTALL ELECTRICAL
JUNCTION BOX CONTAINING TERMINATION
OF TWO (2) 120 VAC/20 AMP POWER CIRCUIT
FROM BUILDING EMERGENCY ELECTRICAL
DISTRIBUTION PANEL TO PROVIDE PRIMARY
POWER FOR FIRE ALARM PANEL
EQUIPMENT. LABEL ASSOCIATED CIRCUIT
BREAKERS "FIRE ALARM CIRCUIT CONTROL."
ELECTRICAL JUNCTION BOX PROVIDED
UNDER ELECTRICAL SECTION. REFERENCE
ELECTRICAL SHEETS FOR PANEL SCHEDULE
AND LOCATIONS OF EMERGENCY POWER
DISTRIBUTION PANELS.
FA216 PROVIDE AND INSTALL NEW ADDRESSABLE
INTERFACE MODULE TO MONITOR WATER
FLOW SWITCH.
FA218 PROVIDE AND INSTALL NEW HVAC DUCT
TYPE SMOKE DETECTOR ON THE SUPPLY
SIDE OF AHU UNIT. CONTRACTOR TO REFER
TO MECHANICAL PLANS FOR EXACT
LOCATION OF AHU UNIT.
FA219 INSTALL FIRE ALARM DEVICE ON MULLION.
ALL FIRE ALARM WIRING IS TO BE RUN
INSIDE MULLION.
FA222 PROVIDE NEW MONACO BT-XM MASS
NOTIFICATION TRANSCEIVER FOR
COMMUNICATION WITHIN THE BUILDING.
FA225 PROVIDE SURGE SUPPRESSOR ON ALL 120
VOLT CIRCUITS TO CONTROL PANELS,
TRANSMITTERS, AMPLIFIER PANELS, AND
BOOSTER PANELS.
FA226 PROVIDE ADDRESSABLE RELAY WITHIN 3
FEET OF DOOR CONTROL PANEL TO
RELEASE DOORS UPON UPON ACTIVATION
OF THE FIRE ALARM SYSTEM.
PATIENT-SENSITIVE AREAS
GRAPHIC LEGEND
SCHEMATIC DESIGN 8.17.2018
DESIGN DEVELOPMENT 11.08.2018
CONTRACT DOCUMENTS 01.04.2019
| FA0-1 - FIRE ALARM ABBREVIATIONS AND SYMBOLS |
| Sheets |
| FA0.1 - FIRE ALARM ABBREVIATIONS AND SYMBOLS |
| FA2.1 - GROUND FLOOR FIRE ALARM SYSTEMS PLAN |
| FP0.1 - FIRE PROTECTION ABBREVIATIONS AND SYMBOLS |
| FP2.1 - GROUND FLOOR FIRE PROTECTION PLAN |
| FA2-1 - GROUND FLOOR FIRE ALARM SYSTEMS PLAN |
| Sheets |
| FA0.1 - FIRE ALARM ABBREVIATIONS AND SYMBOLS |
| FA2.1 - GROUND FLOOR FIRE ALARM SYSTEMS PLAN |
| FP0.1 - FIRE PROTECTION ABBREVIATIONS AND SYMBOLS |
| FP2.1 - GROUND FLOOR FIRE PROTECTION PLAN |
File details come from the government source that posted it. Updated .