W9127821R0051 AM03 DRAWINGS.pdf
PDF 5 MB Posted
- Solicitation number
- W9127821R0051
View the file
Other files
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers®
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE, AL 36602
FY-21 AIRMAN LEADERSHIP SCHOOL FACILITY
NE 20 1
HF20005
21R0051
AMENDMENT NO. 0003
A M
EN
D
R
EM
O
VE
D
"M
AT
O C
T
AS
K O
R D
ER
E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
C T
N
O
U S
A
R M
Y
C
O R
P S
F
E
N G
I N
E E
R S
A N
S I
D
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
U M
B E
R
F I L
E
N
A M
E
S
A I N
T
J O
S E
H
R
E E
T
E G
L I
B
F
L O
R I D
A
A I R
M A
N
L
E A
D E
R S
H
H
O O
L
F
A C
I L
I T
Y
M A
R C
H
- M H
F
TABLE 1: DISCIPLINE DESIGNATOR
WATERLINE
SANITARY SEWER
FIRE HYDRANT
STORM DRAIN
WASTE DRAIN
POST INDICATOR VALVE
CONTOURS
SPOT GRADE ELEVATIONS
DIRECTION OF DRAINAGE
DRILL HOLE
FIRE PROTECTION WATERLINE
GAS
GAS MAIN
MANHOLE SELF EXPLANATORY
DEPENDING ON TYPE OF UTILITY LINE
GATE VALUE & VALVE BOX
OR SERVICE STOP & BOX
UNDERGROUND STEAM SUPPLY GAS METER
SD
W
SS
WD
PIV
US
G
F
GAS MAIN
N 98.8
E 59.7
NORTHING - EASTING LABEL
CORE BORING LOCATION
SILT FENCE BARRIER
OBJECT MARKER
SIGN
CABLE BARRIER
CLEARING AND GRUBBING
CONSTRUCTION LIMIT
TREE LINE
NOTE: SHEET GRID COLUMN AND ROW LOCATION REFER TO THE
LETTERS AND NUMBER WHICH OCCUR ON LEFT SIDE AND TOP
OF BORDER.
CONCRETE VALLEY GUTTER
ASPHALT OR GRAVEL PAVEMENT REMOVAL
2-DIGIT DISCIPLINE DESIGNATOR (SEE TABLE 1)
1-DIGIT SHEET TYPE DESIGNATOR (0-9)
2-DIGIT SHEET SEQUENCE (00-99)
DETAIL NUMBER
SHEET NUMBER OF DWG. WHERE
DETAIL IS SHOWN
C-501
X
SCALE:G7
DETAIL/SECTION / ELEVATION TITLE
SHEET GRID ROW LOCATION
SHEET GRID COLUMN LOCATION
1. RADII ARE SHOWN AT THE EDGE OF TRAVEL WAY (ETW).
2. DIMENSIONS TO GUTTER ARE MEASURED TO THE EDGE
OF ASPHALT PAVEMENT.
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND
ARE PERTINENT TO THE CONDITIONS ON THIS SET OF DRAWINGS
TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY
APPEAR IN THIS SET OF DRAWINGS TO INDICATE SPECIFIC
CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
STORM DITCH FLOW DIRECTION
PAVEMENT MARKING REMOVAL
NEW WORK LEGEND
NEW WORK & PAVEMENTS HATCH LEGEND
SYMBOL IDENTIFICATION
SURVEY / EXISTING CONDITIONS LEGEND
CS101
SHEET NAMING LEGEND
SITE LAYOUT NOTES
GENERAL NOTES
DEMOLITION / REMOVAL LEGEND
SAMPLE SHEET NAME:
SILT FENCE
X X X X
SAFETY FENCE
SEDIMENT TRAP
CONSTRUCTION
ENTRANCE
INLET PROTECTION
CHECK DAM WATTLE
BMP LEGEND
4" UNREINFORCED CONCRETE PAVEMENT
TREE REMOVAL
J D
E F
A L C
O
S T
U R
N E
R
J L O
N G
P O
C
O N
N O
R
P R
O J E
L
G E
N D
M H
F
C d w g
C-003
TREE
C COMM. MANHOLE / PULLBOX
EXISTING ELEVATION
S SANITARY MANHOLE
BOLLARD
GROUND LIGHT
POLE LIGHT
POWER POLE
D DRAINAGE MANHOLE
GUY WIRE
GAS VALVE
FIRE HYDRANT
WATER VALVE
CONTROL POINT
CO SANITARY CLEANOUT
D DRAINAGE INLET
CENTERLINE ROADWAY
UNDERGROUND COMMUNICATION LINE
OVERHEAD/UNDERGROUND ELECTRICAL LINE
STORM DRAIN
SANITARY SEWER
WATER LINE
NATURAL GAS LINE
HAUL ROUTE
GI INDEX/LEGEND SHEETS
C- CIVIL GENERAL
VF EXISTING CONDITIONS
V- SURVEY MONUMENTATION
CD CIVIL DEMOLITION
CS CIVIL SITE
CG CIVIL GRADING
CP CIVIL PAVING
CU CIVIL UTILITY
EXISTING BUILDING
TYPE III BARICADE
DRIP LINE
CONTOUR
SIGN
COMMx
G
WL
SAN
SDx
E
VEGETATION PLAN LEGEND
SOLID SOD
TREE PROTECTION
SEEDING
CONTACTOR STAGING AREA
6" UNREINFORCED CONCRETE PAVEMENT
CONCRETE SIDEWALK OR PCC SLAB
AGGREGATE DRIVE
EXISTING BUILDING
OR
PAVEMENT MARKINGS
PROJECT LIMITS
PAVEMENT MARKINGS
ASPHALT PAVEMENT
A
M N
D
A
D D
P
H A
V
E M
E N
T
T
O
H
A T
G
E N
D 7/
2/
CORNER
POST
BRACE
TRUSS
ROD
2" DIA. TUBULAR STEEL BASE (2' X 3') WITH
18" TO 24", 1-1/2" DIA. POST (TYPICAL)
CHAIN LINK
FABRIC
TENSION WIRE
TENSION WIRE
LINE
POST
10.0' MAXIMUM
MULTIPLES OF 10.0'
MAXIMUM
END BAY
CORNER
POST
BRACE
TRUSS
ROD
RUBBER TIRE
FILLED WITH CONCRETE
(TYPICAL)
CHAIN LINK
FABRIC
TENSION WIRE
TENSION WIRE
LINE
POST
10.0' MAXIMUM
MULTIPLES OF 10.0'
MAXIMUM
END BAY
NOTES:
1. COVER ALL TEMPORARY CONSTRUCTION FENCE WITH
BROWN UV RESISTANT FABRIC. PROVIDE PROPER
ANCHORAGE OF THE FABRIC TO THE FENCE.
NOTES:
1. COVER ALL TEMPORARY CONSTRUCTION FENCE WITH
BROWN UV RESISTANT FABRIC. PROVIDE PROPER
ANCHORAGE OF THE FABRIC TO THE FENCE.
2. TEMPORARY CHAIN-LINK CONSTRUCTION FENCE IN PAVED
AREAS SHALL NOT BE USED FOR SECURITY FENCING.
NONPAVED AREASPAVED AREAS
SCALE: N.T.S.A4
TEMPORARY CHAIN LINK CONSTRUCTION FENCE
ELEVATION
WELDED TUBULAR STEEL BASE
SUPPORT POSTS
1-1/2" OD MAX.
M I N
TEMPORARY
FENCE PANELS
2" OD, WELDED
TUBULAR STEEL
BASE, TYP.
N
H
A
L
F
N
SCALE: N.T.S.A1
TEMPORARY CHAIN LINK CONSTRUCTION FENCE
J D
E F
A L C
O
K K
I R
B Y
J L O
N G
P O
C
O N
N O
R
C O
N S
T R
U C
T I O
N
D
E T
A I L S
M H
F
C d w g
C-006
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I
S
T R
I C
T
M O
B I L E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I
M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L E
A D
E R
S H
H
O O
L
F
A C
I L I T
Y
M A
R C
H
- M H
F
W20-4
W20-7A
W20-4
W20-7A
EXISTING EDGE
OF ROADWAY
EXISTING ROAD
WORK AREA
300' 300' 50'-100'
300' 300'
EXISTING EDGE
OF ROADWAY
50'
18"
DIAMETER
l b s
TUBULAR NON-FIXED
MARKER TO BE USED
DURING DAYLIGHT ONLY
CONES
PLASTIC
DRUMS
M i n
RETROREFLECTIVE
SURFACE
HIGH INTENSITY
FLASHER (TYPE B)
TRAFFIC FLOW DIRECTION
ADVANCE WARNING SIGN
TYPE III BARRICADE
CHANNELIZING CONES
WORK AREA
FLAGMAN
ADVISORY SIGN
TCP LEGEND
N.T.S.
SCALE: N.T.S.D1
ONE LANE CLOSURE PLAN
SCALE: N.T.S.
D5
CHANNELIZING DEVICES
TYPE III BARRICADE
8'-0"
M i n
8" to
12"
8" to
12"
8" to
12"
ROAD
CLOSED
(1) 3/8" - 16x1 3/4" STEEL HEX BOLT
(2) 1" FLAT WASHERS
(1) LOCK-WASHER
(1) 3/8" - 16 STEEL HEX NUT (TYP.)
3/4" ACX PLYWOOD PANEL
ORANGE AND WHITE
REFLECTIVE SHEETING
ASTM D4956 - TYPE OR V
1 1/2" x 1 1/2" x 1/8"
STEEL ANGLE
4'-11" LONG (TYP.)
8" x 2" x 2" x 1/8" TUBULAR STEEL
R11-2
NOTES:
1. THESE LEGENDS ARE COMPOSED OF STANDARD SYMBOLS AND
ARE PERTINENT TO THE CONDITIONS ON THIS SET OF DRAWINGS
TO THE EXTENT APPLICABLE.
2. ADDITIONAL LEGENDS AND/OR ANOTHER LEGEND SHEET MAY
APPEAR IN THIS SET OF DRAWINGS TO INDICATE SPECIFIC
CONDITIONS IN LIEU OF SYMBOLS SHOWN ON THIS SHEET.
A
M N
D
R
E M
O V
N
C I N
G
N
O T
E 7/
2/
N: 546261.9219
E: 1339678.5090
N: 546285.4529
E: 1339672.8980
N: 546193.6519
E: 1339786.5630
N: 546082.3138
E: 1339771.0648
N: 546019.5699
E: 1339729.9160
N: 546015.1518
E: 1339736.1219
N: 545968.0588
E: 1339668.7342N: 546003.7324
E: 1339619.7881
N: 546044.0029
E: 1339595.1437
N: 545982.6119
E: 1339679.3270
N: 546279.9170
E: 1339511.3686
N: 546235.2405
E: 1339585.3322
N: 546308.2457
E: 1339633.9408
N: 545964.7089
E: 1339703.9231
N: 546209.0375
E: 1339789.5119
N: 546218.1855
E: 1339775.4489
N: 546277.8651
E: 1339814.4625
N: 546408.7434
E: 1339614.3256
N: 546349.0639
E: 1339575.3120
N: 546212.9259
E: 1339429.3649
N: 546229.9261
E: 1339440.1443
N: 546211.8034
E: 1339469.4155
N: 546188.8463
E: 1339468.5163
N: 546183.8153
E: 1339499.7138
N: 546105.1986
E: 1339519.1129
N: 546146.8160
E: 1339549.8256
N: 546028.7517
E: 1339789.4088
N: 546046.8890
E: 1339798.2103
N: 546048.9929
E: 1339758.3707
N: 546067.6637
E: 1339766.3540
N: 546098.4428
E: 1339775.9748
N: 546047.6288
E: 1339597.8627
N: 546018.3092
E: 1339630.4169
D5
C-006
D5
C-006
EL. 32.68
CP-1
N 546386.88
E 1339586.55
EL. 25.75
CP-2
N 546106.95
E 1339810.87
EL. 27.51
CP-3
N 546023.44
E 1339523.13
D
D
C
D
C
D
COMMx COMMx
COMMx COMMx
C
O
M
M x
COMMx COMMx
S
D x
C
O
M
M x
C
O
M
M x
C
O
M
M x
C
O
M
M x C
O M
M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x C
O M
M x
C O
M M x
COMMx
C
O
M
M x
C
O
M
M x
C
O
M
M x
C
O
M
M x
S D x
S D x
S D x
S D x
S D x
S D x
S D x
S D x
ASPHALT PARKING
A S
P H
A
LT
R A
O D
D
A D
E R
O A
D
A S
P H
A
A
D
O
C A
A
D
A S
P H
A
A
D
W
E S
T
H
Y M
A
D
A S
P H
A
LT
P A
R K
IN
G
GRAVEL
PAVEMENT
PULL UP
BARS
PINE
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
R C
P
P
R C
P
R
C P
C
O
C.O.
S
C
D
D
INV. 32.67'
D
C
O
W
L
W L
W
L
W L
W L
W
L
W L
W L
W L
W
L
W L
W L
WL
W L
W L
W L
W L
W L
W L
WLWL
W L
W L
BASE CHAPEL
BUILDING 868
G
G
G
G
G
G
G
G
G
S
D x
S
D x
D
C
A
T
B
S
I
N
S
D x
S
D x
S
D x
S
D x
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
G
A
L
A
L
A
L
A
L
A
L
A
L
GRASS AREA
GRASS AREA
GRASS
ISLAND
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I L
E
N
A M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L
E A
D E
R S
H
H
O O
L
F
A C
I L
I T
Y
M A
R C
H
- M H
F
SCALE:
30' 60'30
1"=30'
PLAN NORTH
NOTE:
1. FOR LOCATION MAP AND HAUL ROUTES SEE SHEET C-001.
2. FOR ABBREVIATIONS SEE SHEET C-002.
3. FOR PLAN LEGEND SEE SHEET C-003.
4. FOR PROJECT NOTES SEE SHEET C-004.
KEYED NOTES
FULL DEPTH SAWCUT, ASPHALT PAVEMENT REMOVAL
GRAVEL PAVEMENT REMOVAL
EXISTING PARKING MARKING AND PARKING BLOCK REMOVAL
LONG LEAVE PINE REMOVAL (COORDINATE WITH JACKSON GUARD
THROUGH COR)
REMOVE NORTH DUMPSTER PAD WALL AND 2' OF PCC SLAB.
TREE TO REMAIN, NO CONSTRUCTION ACTIVITY SHALL OCCUR WITHIN
THE LIMITS OF THE DRIPLINE OF THE TREE.
LIGHT POST TO REMAIN, TYPICAL
BERM TO BE REMOVED
POLE TO BE REPLACED. SEE ELECTRICAL PLANS
RAISED WOODEN STRUCTURE TO REMAIN, DO NOT DISTURB
REMOVE EXERCISE PULL UP BARS
CONTRACTOR STAGING/LAY-DOWN AREA
CLEARING/ TOPSOIL STRIPPING LIMIT
TYPE III BARRICADES WITH ROAD CLOSURE SIGNS
J D
E F
A L C
O
S T
U R
N E
R
J L O
N G
P O
C
O N
N O
R
D E
M O
L I T
I O
N
P
L A
N
M H
F
C D d w g
CD101
A
M N
D
A
D D
V
E M
E N
T
R
E M
O V
T
C H
7/
2/
EL. 32.68
CP-1
N 546386.88
E 1339586.55
EL. 25.75
CP-2
N 546106.95
E 1339810.87
EL. 27.51
CP-3
N 546023.44
E 1339523.13
D
D
C
D
C
D
COMMx COMMx
COMMx COMMx
C
O
M
M x
COMMx COMMx
S
D x
S D x
C
O
M
M x
C
O
M
M x
C
O
M
M x
C
O
M
M x C
O M
M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x
C O
M M x C
O M
M x
C O
M M x
COMMx
C
O
M
M x
C
O
M
M x
C
O
M
M x
C
O
M
M x
S D x
S D x
S D x
S D x
S D x
S D x
S D x
S D x
CURB AND
GUTTER
OAK
ASPHALT PARKING
A S
P H
A
LT
R A
O D
D
A D
E R
O A
D
A S
P H
A
A
D
O
C A
A
D
A S
P H
A
A
D
W
E S
T
H
Y M
A
D
A S
P H
A
LT
P A
R K
IN
G
CONC.
DUMPSTER
PAD
C
O
N
C
R
E
T
E
S
I
D
E
W
A
L
K
INV. 29.56'
INV. 30.53'
INV. 30.93'
R C
P
P
R C
P
R
C P
INV. 23.47'
C
O
C.O.
S
C
D
D
INV. 32.67'
INV. 31.55'
D
C
O
W
L
W L
W
L
W L
W L
W
L
W L
W L
W L
W
L
W L
W L
WL
W L
W L
W L
W L
W L
W L
WLWL
W L
W L
BASE CHAPEL
BUILDING 868
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
GAS
SAN
SAN
SAN
SAN
SAN
MH 185
RIM EL = 24.24'
INV. IN = 19.10'
INV. OUT = 19.09
MH
RIM EL. = 34.55'
INV. IN = 28.77'
INV. OUT = 28.75'
S
D x
S
D x
D
C
A
T
B
S
I
N
S
D x
S
D x
S
D x
S
D x
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
G A
S
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
S A
N
TOP EL 26.30'
A
L
A
L
A
L
A
L
A
L
A
L
GRASS AREA
EX-1
EX-2
EX-3
EX-4
GRASS
ISLAND
CURB AND
GUTTER
CONC.
FLUME
CURB AND
GUTTER
N: 546185.8562
E: 1339617.8684
N: 546117.3138
E: 1339567.9779
N: 546022.6688
E: 1339697.9359
N: 546168.6883
E: 1339668.6429
N: 546087.1282
E: 1339762.0031
N: 546098.6279
E: 1339764.9314
N: 546099.0894
E: 1339775.4082
N: 546073.8285
E: 1339768.3363
N: 546205.3931
E: 1339465.4729
N: 546218.5084
E: 1339444.1485
.0
.0
T
Y
P
N: 546197.8888
E: 1339468.1301
N: 546202.7737
E: 1339469.7319
AIRMAN LEADERSHIP SCHOOL
FFE 28.00'
N: 546160.1546
E: 1339537.2185
N: 546173.2699
E: 1339515.8941
N: 546056.2993
E: 1339760.8969
N: 546044.6354
E: 1339778.7826
D5
C-006
D5
C-006
D1
CS503
A1
CS402
A1
CS505
A1
CS404
D1
CS404
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
E
D8
CS502
A1
CS401
A1
CS403
BASE
BID
BID
OPTION 1
BID
SCHED-1
BID
OPTION 1
BID
SCHED-2
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I L
E
N
A M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L
E A
D E
R S
H
H
O O
L
F
A C
I L
I T
Y
M A
R C
H
- M H
F
SCALE:
30' 60'30
1"=30'
PLAN NORTH
NOTE:
1. FOR LOCATION MAP AND HAUL ROUTES SEE SHEET C-001.
2. FOR ABBREVIATIONS SEE SHEET C-002.
3. FOR PLAN LEGEND SEE SHEET C-003.
4. FOR PROJECT NOTES SEE SHEET C-004.
5. CONCRETE HATCH NOT SHOWN FOR CLARITY.
KEYED NOTES
SIDEWALK, 5' TYPICAL, SEE DETAILS CS502.
4" SOLID WHITE STRIPE ANGLED AT 45 DEGREES SPACED AT 18" O.C. AND
OUTLINED WITH A 4" SOLID WHITE STRIPE.
PROPOSED 20' FLAGPOLE SEE STRUCTURAL/ARCHITECTURAL DRAWINGS.
BID OPTION 1: REVEILLE PAD
STOOP SEE STRUCTURAL PLANS FOR DETAILS.
CROSS WALK SEE DETAIL CS503.
CONTRACTOR STAGING AREA
6" THICK AGGREGATE MAINTENANCE DRIVE
PEDESTRIAN GUIDERAIL SEE DETAILS ON CS504
6" CONCRETE SIDEWALK, LIMITS OF MAINTENANCE DRIVE TO THE NEAREST
JOINT.
PROVIDE PREMOLDED JOINT FILLER WITH JOINT SEALER. AT 6" TO 4"
TRANSITION
TYPE III BARRICADES WITH ROAD CLOSED SIGN
J D
E F
A L C
O
K K
I R
B Y
J L O
N G
P O
C
O N
N O
R
S I T
E
P
L A
N
M H
F
C S d w g
CS101
A
M N
D
A
D D
V
E M
E N
T
P
A T
C H
R
EV
IS
ED
K
EY
N
O
TE
7/
2/
W
D
T
H
L
E
N
G
Q
D
N
C
O
N
D
E
W
A
L
K
T
R
A
V
W
Y
PLAN VIEW
WIDTH VARIES (SEE PLANS)
(SEE NOTE 1)
FLUSH IF ABUTS
SIDEWALK
SOLID SOD
SOLID SOD
COMPACTED SUBGRADE
4" PC CONCRETE
NOTES:
1. SIDEWALK TRANSVERSE SLOPE SHALL BE 1/8" PER FOOT MINIMUM AND 1/4" PER FOOT
MAXIMUM.
2. PROVIDE CONTRACTION JOINTS AT A DISTANCE EQUAL TO THE WALK WIDTH OR AS
INDICATED ON PLAN.
3. CONTRACTION JOINTS SHALL BE PLACED TO CREATE RECTANGULAR AREAS WITH THE
LONGEST DIMENSION NO GREATER THAN THAN 1.25 TIMES THE THE SHORTER DIMENSION.
4. PLACE TRANSVERSE EXPANSION JOINTS AT REGULARLY SPACED INTERVALS. THE SPACING
SHOULD NOT BE LESS THAN 30 FEET NOR MORE THAN 50 FEET.
5. PROVIDE EXPANSION JOINTS AT WALK RETURNS AND WHERE WALK ABUTS BUILDINGS,
CURBS AND SIDEWALKS.
6. SIDEWALKS SHALL BE 4-INCHES THICK AND SHALL BE PLACED ON COMPACTED SUBGRADE.
FOR SUBGRADE PREPARATION AND COMPACTION REQUIREMENTS, SEE SPECIFICATION 31 00
00 EARTHWORK.
7. SIDEWALKS ADJACENT TO BUILDINGS SHALL BE CONSTRUCTED WITH THE TRANSVERSE
SLOPE SLOPING AWAY FROM THE BUILDINGS.
8. AT DOOR THRESHOLDS, SIDEWALKS SHALL BE CONSTRUCTED IN ACCORDANCE WITH ABA
AND NFPA REQUIREMENTS. AT PEDESTRIAN DOOR THRESHOLDS, SIDEWALKS SHALL BE AS
INDICATED ON ARCHITECTURAL DRAWINGS.
3/8" to 1/2" R
1/2"
JOINT SEALER
1/2" PREMOLDED
EXPANSION
JOINT FILLER
CONTRACTION JOINT EXPANSION JOINT
TEE INTERSECTION
LONGER RUN OF
SIDEWALK
CONTRACTION JOINT, TYP.
1/2" PREMOLDED
EXPANSION JOINT FILLER
SHALL BE PLACED
PARALLEL WITH THE
LONGER RUN OF SIDEWALK
3/8" to 1/2" R
1/8"
SCALE: N.T.S.
A1
STANDARD SIDEWALK
8"
STEEL ROD
1" DIA. x 1'-6"
2500 p.s.i. CONCRETE
ELEVATION
SECTION
2'-1"
2'-1"
6'-0"
10"8" 8"
FINISH GRADE
5" 5"
5" 5"
1/4 " RADIUS
FINISH GRADE
2-#3 BARS
1 1/2 "
6" 2"
2"
10"
TYP
1 1/2 "
5"
5"
SCALE:
A8
PRECAST CONCRETE PARKING BUMPER
SCALE:
A5
ISOMETRIC HANDICAP RAMP AND DETECTABLE WARNING
DETECTABLE WARNING,
SEE FDOT STANDARDS FOR TYPE
1'-4"
SECTION VIEW
SCALE:
E1
TYPICAL PAVEMENT PATCH DETAIL
4"
SCALE:
F5
SECTION WHERE SIDEWALK MEETS EXISTING PAVEMENT
DETECTABLE WARNING
SURFACE TACTILE PAD
SAWCUT EXISTING
PAVEMENT TO CREATE
CLEAN VERTICAL EDGE
EXISTING PAVEMENT
STRUCTURE
CONCRETE
SIDEWALK
6" GCAB
SURFACE
6" COMPACTED
SUBGRADE
SCALE: N.T.S.
D8
MAINTENANCE ACCESS DRIVE SECTION
2'-0"
6" CONCRETE
SIDEWALK
6" COMPACTED
SUBGRADE
SCALE: N.T.S.
D5
SIDEWALK SECTION AT MAINTENANCE ACCESS DRIVE SECTION
GCAB
24" PLUS WIDTH OF
PIPE O.D.
FULL DEPTH SAW CUT EDGED
STRAIGHT AND PARALLEL
24" PLUS TRENCH WIDTH
GRADED CRUSHED AGGREGATE
BASE SPECIFICATION 31 11 23
4" FDOT PAVEMENT AS
APPROVED BY THE COR
12" MIN.
TYP.
EXISTING ASPHALT
PAVEMENT, TYP.
TACK COAT,
TYP.
TACK COAT,
TYP.
V A
R I E
S
S
G
A
D I N
G
P L
P
T H
S
MATCH EXISTING
BASE THICKNESS
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I L
E
N
A M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L
E A
D E
R S
H
H
O O
L
F
A C
I L
I T
Y
M A
R C
H
- M H
F
J D
E F
A L C
O
K K
I R
B Y
J L O
N G
P O
C
O N
N O
R
C I V
I L
D
E T
A I L S
S I D
E W
A L K
A
C C
E S
S
D
R I V
E
A
N D
P A
R K
I N
G
B
U M
P E
R
M H
F
C S d w g
CS502
N.T.S
N.T.S
N.T.S
N.T.S
N.T.S
A
M N
D
R
E
VI
SE
D
D
ET
AI
LS
7/
2/
3"
E
I G
S
Y M
B O
L
WIDTH OF SYM.
34"
BLUE BACKGROUND
WHITE BORDER
WHITE SYMBOL
NOTES:
1. HANDICAPPED MARKING SHALL BE
APPLIED IN ACCORDANCE WITH
M.U.T.C.D. FIGURE 3B-22.
2"X2" SQ. STL. POST
(PAINT RUSSETT
BROWN FED #30108)
30"
GRAVEL
CONCRETE
FINISH GRADE
GALVANIZED STEEL NUTS,
BOLTS AND WASHERS
12"
WHITE H.C. SYMBOL ON
BLUE BACKGROUND
COLORS:
TEXT AND BORDER - GREEN
WHITE H.C. SYMBOL ON BLUE BACKGROUND
BACKGROUND - WHITE
BACK FACE OF SIGN - BROWN
SIGN INSTALLATION
1.5"R
TYP.
CONCRETE
SIDEWALK
CONCRETE
SIDEWALK
4" WIDE BLUE
PAINT STRIPE
9' 9'9'
4" SOLID WHITE LINE
NOT TO SCALE
A5
SIGN DETAILS
SOLID PARKING STRIPE
PER SITE PLAN
24" SOLID WHITE LINE
(SEE SPECIFICATIONS)
NOT TO SCALE
D1
HANDICAP PARKING DETAIL
NOT TO SCALE
A3
HANDICAP PAVEMENT MARKING
VAN ACCESSIBLE HC PARKING
M A
X
4" WIDE BLUE
PAINT STRIPE
A3
CS503
F5
CS502
2' 2'
A5
CS506
PEDESTRIAN CROSSING
NOT TO SCALE
D6
PAVEMENT MARKING DETAILS
A3
CS503
A5
CS506
NOTE:
VAN ACCESSIBLE SIGN IS ONLY REQUIRED FOR SPACE
WITH ADJACENT 9' WIDE ACCESSIBLE ROUTE
A8
CS502
A8
CS502
CONCRETE PARKING
BUMPER, TYP.
DETECTABLE
WARNING STRIP
J D
E F
A L C
O
K K
I R
B Y
P
O
C O
N N
O R
J
L O
N G
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I L
E
D
I S
T R
I C
T
M O
B I L
E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I L
E
N
A M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L
E A
D E
R S
H
H
O O
L
F
A C
I L
I T
Y
M A
R C
H
- M H
F
J D
E F
A L C
O
K K
I R
B Y
P
O
C O
N N
O R
J
L O
N G
C I V
I L
D
E T
A I L S
P A
V E
M E
R
K I N
G
A N
D
S
I G
N A
G E
M H
F
C S d w g
CS503
A
M N
D
U
P D
A T
N
D I C
R
K I N
G
D
E T
A I L
7/
2/
NOTE:
INJECTION MOLDED FITTINGS ARE AVAILABLE
IN TEES, WYES, REDUCERS, 45° BENDS AND
BELL/BELL COUPLERS.
WATERTIGHT (WT) JOINTS SHOWN. SOIL-TIGHT (ST)
FITTINGS ARE ALSO AVAILABLE.
*DOWNSPOUT SHALL TIE TO STORM DRAIN LINE OR
NEAREST STORM STRUCTURE
FINISHED GRADE
CLEANOUT END CAP
ADJUST GRADE PER
ENGINEERS PLAN
INJECTION MOLDED WT
45° WYE
INSERT INJECTION MOLDED,
GASKETED SPIGOT BY
BELL REDUCER
INJECTION MOLDED
WT TEE*
HDPE PIPE (TYP)
GASKETED
CONNECTION
INJECTION
MOLDED WT
90° BEND
INJECTION MOLDED
WT 45° BEND
DOWNSPOUT ADAPTER
INSERTED IN RISER
PIPE
NOTE:
INJECTION MOLDED FITTING ARE AVAILABLE
IN TEES, WYES, REDUCERS, 45° BENDS AND
BELL/BELL COUPLERS.
WATERTIGHT (WT) JOINTS SHOWN. SOIL-TIGHT (ST)
FITTINGS ARE ALSO AVAILABLE.
*DOWNSPOUT SHALL TIE TO STORM DRAIN LINE OR
NEAREST STORM STRUCTURE
INJECTION MOLDED
WT TEE
INSERT INJECTION MOLDED,
GASKETED SPIGOT BY
BELL REDUCER
INJECTION MOLDED
WT TEE*
HDPE PIPE (TYP)
GASKETED
CONNECTION
INJECTION
MOLDED WT
90° BEND
DOWNSPOUT ADAPTER
INSERTED IN RISER
PIPE
ROOF DRAIN
SIZE VARIES
SEE GRADING PLANS
SEE DRAINAGE SCHEDULE
FOR ELEVATIONS.
FINISHED GRADE
CLEANOUT END CAP
ADJUST GRADE PER
ENGINEERS PLAN
ROOF DRAIN
SIZE VARIES
SEE GRADING PLANS
SEE DRAINAGE SCHEDULE
FOR ELEVATIONS.
CONT. CONC. FOOTING
SEE STRUCT. DWG. TYP.
FACE OF WALL
SEE ARCH. DWGS. TYP.
METAL DOWNSPOUT
FLEXIBLE DRAIN
ADAPTOR
CONT. CONC. FOOTING
SEE STRUCT. DWG. TYP.
FACE OF WALL
SEE ARCH. DWGS. TYP.
METAL DOWNSPOUT
FLEXIBLE DRAIN
ADAPTOR
SCALE: N.T.S.
D1
ROOF DRAIN W/ TEE CLEAN OUT
SCALE: N.T.S.
A1
ROOF DRAIN W/ WYE CLEAN OUT
SCALE: N.T.S.
A6
SINGLE CONCRETE PIPE MITERED END-SECTION
Connector
Saddle
Construction Joints Permitted
POND BOTTOM
Sta./Offset Location
TOP VIEW-SINGLE PIPE
SECTION
N M
GFECBAXD
Single
Pipe
Double
Pipe
Triple
Pipe
Quad
Pipe
12" 2.27' 4.09' 6.36' 4.03' 8' 1.22' 4.63' 1.19'2'-7" 4.0' 0.76 1.16 1.54 1.94
H
1'
M
D
W i d t h
A b o v e
G
A
C
B
D
2'
Not < Than D
6"
E
F
3'
N
1'
M i n
H
6"
CONCRETE (CY)
Concrete
Pipe
MAINTAIN SAME CROSS-SECTIONAL AREA
AS DOWNSPOUT TO THE NEAREST SIZE PIPE.
6" MIN. PIPE.
MAINTAIN SAME CROSS-SECTIONAL AREA
AS DOWNSPOUT TO THE NEAREST SIZE PIPE.
6" MIN. PIPE.
J D
E F
A L C
O
K K
I R
B Y
J L O
N G
P O
C
O N
N O
R
D R
A I N
A G
E
D
E T
A I L
S
M H
F
C G d w g
CG501
D E
S C
R I P
T I O
N M
A R
K D
A T
E
US Army Corps of Engineers
AMENDMENT NO. 0003
SHEET ID
S O
L I C
I T
A T
I O
N
N
O
D E
S I G
N E
D
B
Y
S I Z
E
S U
B M
I T
T E
D
B
Y
C O
N T
R A
U S
A
R M
Y
C
O R
E
N G
I N
E E
R S
A N
S I
D
M O
B I
S
T R
I C
T
M O
B I L E
A
L A
B A
M A
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
I S
S U
E
D
A T
E
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9
P R
O J E
M
B E
R
F I
M
E
S
A I N
T
J O
S E
R
E E
T
E G
L
B
F
L O
R I D
A
A I R
M A
N
L E
A D
E R
S H
H
O O
L
F
A C
I L I T
Y
M A
R C
H
- M H
F
A
M N
D
A
D D
T
E 7/
2/
01_LEVEL_FF
0"
GRID
2'
0"
SE
E
SC
H
ED
U
LE
CONT. MOISTURE
BARRIER, TYP.
6" CAPILLARY
MATERIAL, TYP.
COMPACTED STRUCTURAL
FILL, TYP.
SEE SCHEDULE FOR
REINFORCEMENT, TYP.
PEMB COULMN, TYP
SEE ARCH. FOR WALL
CONSTRUCTION
SEE SCHEDULE
HAIRPIN REINF PER PLANS
& TYPICAL DETAILS
SLAB REINF PER PLAN, TYP.
C
LR2"
2" CLR, TYP
(4) #6 @ EA SIDEWALL
ANCHOR GROUP, SEE
FOOTING DOWEL DETAIL,
THIS SHEET
#4 STIRRUP
@ 24" O.C., TYP
(4) #6 BARS
CONT, TYP
WIND BEAM BY P.E.M.B.,
TYP.
CLIP BY CONTRACTOR
LIGHT GAUGE FRAMING,
TO BE DESIGNED BY
CONTRACTOR, TYP.
8" 1'
4"
6"
#4 U-BAR @
24" O.C., TYP.
(2) #4 BARS
CONT, TYP.
1' - 3"
9"
01_LEVEL_FF
0"
GRID
CONT. MOISTURE
BARRIER, TYP.
6" CAPILLARY
MATERIAL, TYP.
SLAB & REINF PER PLAN, TYP
PEMB COULMN, TYP
SEE ARCH. FOR WALL
CONSTRUCTION
#4 STIRRUP @ 24" O.C., TYP.
(4) #6 BARS CONT, TYP.
LIGHT GAUGE FRAMING,
TO BE DESIGNED BY
CONTRACTOR, TYP.
#4 U-BAR @ 24" O.C.,
TYP.
(2) #4 BARS CONT,
TYP. 6"
3' - 6"
8" 1'
4"
2'
0"
9"
1' - 3"
01_LEVEL_FF
0"
SLOPE
1/8" PER FOOT
BUILDING SLAB,
SEE PLAN, TYP.
CONCRETE SLAB,
SEE PLAN FOR THICKNESS
AND REINFORCING, TYP.
10"
TH
IS
S H
EE
T
SE
E
TY
PI
C
AL
ST
O
O P
SE
C
TI
O
N
1/ 8"
A
1 CONT. MOISTURE
BARRIER, TYP.
6" CAPILLARY
MATERIAL, TYP.
SLAB & REINF PER PLAN, TYP
#4 STIRRUP @ 24" O.C., TYP.
(4) #6 BARS CONT, TYP.
PEMB COULMN, TYP
SEE ARCH. FOR WALL
CONSTRUCTION
LIGHT GAUGE FRAMING,
TO BE DESIGNED BY
CONTRACTOR, TYP.
#4 U-BAR @ 24" O.C.,
TYP.
(2) #4 BARS CONT,
TYP. 6"
2' - 6"
8" 1'
4"
2'
0"
01_LEVEL_FF
0"
CONT. MOISTURE
BARRIER, TYP.
SLAB & REINF PER PLAN, TYP
SEE ARCH. FOR WALL
CONSTRUCTION
#4 STIRRUP @ 24" O.C., TYP.
(4) #6 BARS CONT, TYP.
#4 U-BAR @ 24" O.C.,
TYP.
(2) #4 BARS CONT,
TYP.
6"
3' - 6"
1'
4" 8"
2'
0"
GRID
(3) #6 BANDED DOWEL
ANCHOR BOLTS, TYP.
GRID
COLUMN & BASE PLATE
EDGE OF SLAB
(1) #6 BANDED DOWEL
01_LEVEL_FF
0"
8" CMU WALL, SEE S-001
FOR WALL REINFORCING
AND SPACING, TYP.
CONT. MOISTURE
BARRIER, TYP.
6" CAPILLARY
MATERIAL, TYP.
SLAB & REINF PER
PLAN, TYP
#4 @ 12" O.C., TYP.
(2) #4 BARS, CONT,
TYP.
DOWELS, MATCH WALL
REINFORCEMENT SIZE
AND SPACING, TYP.
1' - 0"1' - 0"
1'
0"
BOND BEAM REINF PER
NOTES ON S-001, TYP.
BUILDING SLAB,
SEE PLAN, TYP.
CONCRETE SLAB,
SEE PLAN FOR THICKNESS
AND REINFORCING, TYP.
SLOPE
1/8" PER FOOT
(2) #5 BARS
CONT., TYP.
M
I N
1'
0"
10"
1/ 8"
**NOTE:
MINIMUM TOTAL DEPTH SHOWN. INCREASE
TOTAL DEPTH AS REQUIRED TO ENSURE A
10" MINIMUM DEPTH BELOW FINISHED GRADE.
TOP OF CONCRETE
PR
O
J
A.
B.
L
EN
G
TH
1/ 2"
(2) HEAVY HEX NUTS
HEAVTY HEX NUT
ANCHOR BOLT
STD WASHER
OVERSIZED WASHER
A.B. DIA. A.B. LENGTH PROJ
3/4" 18" 5"
7/8" 22" 6"
≥1" 23" 6"
BOT OF COL BASE PLATE
NON-SHRINK GROUT
LEVELING NUT W/
STD WASHER
1/
2"
TACK WELD
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
S-301
AI
R
M
EN
L
EA
D
ER
SH
IP
S C
H O
O L
FA
C
IL
IT
Y M
O
BI
LE
D
IS
TR
IC
T
A.
JU
ST
IC
E
J.
BA
IL
EY
J.
O
R
TI
Z
M
AR
C H
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
F2
AMENDMENT 0003
EG
LI
N A
IR
F
O R
C E
BA
SE
, F L
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FO
U
N D
AT
IO
N S
EC
TI
O N
S
3/4" = 1'-0"1 SECTION
3/4" = 1'-0"2 SECTION
3/4" = 1'-0"3 SECTION
3/4" = 1'-0"4 SECTION
3/4" = 1'-0"
FOOTING DOWEL DETAIL
3/4" = 1'-0"6 SECTION
3/4" = 1'-0"
TYPICAL STOOP SECTION
M
AR
K D
AT
E
AM
E N D
3, R
EV
IS
ED
D
R
AW
IN
G
IN
R
ES
P O
N
SE
T O
R
FI
/0 2/
1 1/2" = 1'-0"8 ANCHOR BOLT DETAIL
T/
TY
PI
C
AL SE
E
PL
AN
SAW CUT JOINT,
1/8"X1/4 OF THICKNESS
OF SLAB
REINFORCEMENT
VAPOR BARRIER, TYP.CAPILLARY WATER
BARRIER, TYP.
CONTROL JOINT (CJ)
FORMED EDGE
REINFORCED
CONCRETE
STOP REINFORCEMENT
2" EACH SIDE OF JOINT
PL
AN
SE
E
T/
TY
PI
C
AL
CAPILLARY WATER
BARRIER, TYP.
VAPOR BARRIER, TYP.
CONSTRUCTION JOINT (CTJ)
SEE MANUFACTURERS SPEC.
EQUIPMENT FURNISHED EDGE OF EQUIP.EDGE OF EQUIP.
6X6-W2.9XW2.9 W.W.F.
CENTERED IN SLAB
#3 @ 24" O.C.
@ PERIMETER
SEE PLAN FOR SLAB
THICKNESS AND REINF.
4"4"
TY
P.6"
VAPOR BARRIER,
TYP.
6" CAPILLARY
WATER BARRIER, TYP.
EQUIPMENT PAD DETAIL
1'
0" TY
P.6"
SEE MANUFACTURER'S SPEC.
EQUIPMENT FURNISHED
TYP.
6"
TYP.
6"
3/4" CHAMFER, TYP.
#4 @ 12" EACH WAY, TOP AND BTM.
EXTERIOR EQUIPMENT PAD DETAIL
(2) #4 x3'-0"
1" BELOW
TOP OF SLAB
2"4" EDGE OF
SLAB OR SCJ
1/2"
1/2"
1/2"
CONTRACTION JOINT SEALANT DETAIL
CONSTRUCTION JOINT SEALANT DETAIL EXPANSION JOINT SEALANT DETAIL
INITIAL 1/8" SAW CUT
SEALANT SHALL BE 1/8"
BELOW FINISHED GRADE
SEALANT PER FLOOR
SEALANT MANUFACTURER
REQUIREMENTS
SEALANT SHALL BE 1/8"
BELOW FINISHED GRADE
SEALANT SHALL BE 1/8"
BELOW FINISHED GRADE
NON-EXTRUDING PREMOLDED
COMPRESSIBLE MATERIAL
SEALANT PER FLOOR
SEALANT MANUFACTURER
REQUIREMENTS
SEALANT PER FLOOR
SEALANT MANUFACTURER
REQUIREMENTS
M
IN
Y
FOUNDATION
SE
E
SE
C
TI
O
N S
2' - 0"
UTILITY, SEE MECH.,
ELEC., OR PLUMBING FOR
LOCATION AND DEPTH
SLEEVE OPENING THRU FOOTING
INSIDE DIAMETER = O.D. UTILITY PIPE + 3",
FILL ANNULAR SPACE W/ COMPRESSIBLE MATERIAL
UTILITY UNDER WALL FOOTING DETAIL
PERMITTED FOR "Y" < 20"
FOUNDATION
UTILITY, SEE MECH.,
ELEC., OR PLUMBING FOR
LOCATION AND DEPTH
UTILITY UNDER WALL FOOTING DETAIL
PERMITTED FOR "Y" > 20"
PROVIDE UTILITY LINE ENCASEMENT
PER MECH., ELEC., OR PLUMBING
Y
SE
E
SE
C
TI
O N
S
UTILITY LINES PARALLEL TO
WALL FOOTING NOT PERMITTED
WITHIN LINE SHOWN
A
A
TYPICAL BOTTOM WALL FOOTING REINF.
DISCONTINUE IF CONFLICTING WITH UTILITY
SECTION A-A
SE
E
D
ET
AI
LS
FOUNDATION
Y
M
IN
MATCH TYPICAL BOTTOM
WALL FOOTING REINF.
MIN
1 6 "
EACH SIDE
1' - 6"
EACH SIDE
1' - 6"
'-0
(T
YP
TYP.
20.00°
HAIRPIN REBAR,
SIZE PER PLAN, TYP.
1' - 6"
1' - 6"
PLACE AS CLOSE AS
PRACTICAL TO EXTERIOR
ANCHOR RODS
1'
6"
3'
0"
#4 - 1" CLR FROM
TOP OF SLAB
CONTROL OR
CONSTRUCTION
JOINT
2"2"2"GROUT AND
REINFORCE
(2) CELLS
BOND BEAM
REINFORCING
GROUT AND
REINFORCE
(3) CELLS, AS
SHOWN
CORNER BARS
TO MATCH HORIZ
REINFORCEMENT
END OF WALL
INTERSECTION OF WALL
C LIGHTNING GROUND SPIKE
STEEL SUPPORT PLATE
STEEL CENTERING WEDGES
CORRUGATED STEEL SLEEVE
(16 GAUGE GALVANIZED)
TAMPED DRY SAND
3000 PSI (MIN)
CONCRETE
HARDWOOD WEDGES
FLASH COLLAR OVER 2"
WATERPROOF COMPOUND
B
A
NOTES:
1. FLAGPOLE SHALL BE TAPERED AND SIZED PER THE MANUFACTURER'S
REQUIREMENTS BASED ON THE EXPOSED MOUNTING HEIGHT, OR AS OTHERWISE
REQUIRED BY THE SPECIFICATIONS.
2. FLAGPOLE SHALL BE STAINLESS STEEL OR ALUMINUM, WITH MATCHING
COMPONENTS.
3. LIGHTNING KIT SHALL SUPPLY THE REQUIRED PROTECTION AND SHALL BE
RECOMMENDED BY THE MANUFACTURER, OR AS OTHERWISE REQUIRED BY THE
SPECIFICATIONS.
4. COMPONENTS NOT SPECIFIED TO EXACT SIZE IN DETAIL SHALL BE AS
RECOMMENDED BY THE FLAGPOLE MANUFACTURER, OR AS REQUIRED BY THE
SPECIFICATIONS.
EXPOSED
MOUNTING
HEIGHT (FT)
MINIMUM FLAGPOLE FOOTING DIMENSIONS
A B C
2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 6'-0" 7'-0"
30" 36" 36" 36" 45" 45" 50" 60" 60"
24" 30" 30" 30" 36" 36" 42" 48" 48"
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
S-501
AI
R
M
EN
L
EA
D
ER
SH
IP
S C
H O
O L
FA
C
IL
IT
Y M
O
BI
LE
D
IS
TR
IC
T
A.
J U
ST
IC
E
J.
BA
IL
EY
J.
O
R
TI
Z
M
AR
C H
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
F2
AMENDMENT 0003
EG
LI
N A
IR
F
O R
C E
BA
SE
, F L
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
TY
PI
C
AL
S
TR
U C
TU
R
AL
D
ET
AI
LS
3/4" = 1'-0"
RE-ENTRANT CORNER
3/8" = 1'-0"
TYPICAL HAIRPIN DETAIL
3/4" = 1'-0"
DISCONTINUOUS SLAB JOINT DETAIL
3/4" = 1'-0"
TYP CMU WALL DETAILS
M
AR
K D
AT
E
AM
E N D
3, R
EV
IS
ED
D
R
AW
IN
G
IN
R
ES
P O
N
SE
T O
R
FI
/0 2/
3/4" = 1'-0"
FLAGPOLE FOUNDATION DETAIL
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
FX001
AI
R
M
AN
L
EA
D
ER
SH
IP
S C
H O
O L
FA
C
IL
IT
Y M
O
BI
LE
D
IS
TR
IC
T
R .R
EI
C
H
R .R
EI
C
H
W .K
N
AP
P
R .S
M
IT
H
M
AR
C H
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
F2
-M
EC
H
.rv t
M H
F2
EG
LI
N A
IR
F
O R
C E
BA
SE
, F L
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FI
R
E
SU
PP
R
ES
SI
O N
L
EG
EN
D
M
AR
K D
AT
E
AD
D
ED
N O
T E F
O R
F
IR
E
EX
TI
N
G U
I S H
ER
S
GENERAL NOTES AND SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSARILY USED ON THE DRAWINGS)
GENERAL NOTES
VALVE IN DROP
GATE VALVE
TEST PORT
PRESSURE GAUGE
PRESSURE CONTROL VALVE
RELIEF VALVE
CHECK VALVE
WITH GAUGE COCK
BLOWDOWN VALVE
ECCENTRIC REDUCER
TEE OUTLET DOWN
TEE OUTLET UP
STRAINER WITH
UNION
VALVE IN CENTER DROP
DIRECTION OF SLOPE DOWN
CONCENTRIC REDUCER
DIRECTION OF FLOW
VALVE IN RISE
ELBOW DOWN
ELBOW UP
PIPING SYMBOLS
WATER FLOW INFORMATION DRAWING ABBREVIATIONS
DRAWING/DETAIL REFERENCE KEY
RE : 2 / M-201
REFER TO
DRAWING/DETAIL NUMBER
SHEET NUMBER ON WHICH
DETAIL IS DRAWN
M-201
LOCATION: EGLIN AFB, FLORIDA
DATE & TIME OF TEST: 15 JAN 2020 AT 0900
FLOW HYDRANT: A
TEST HYDRANT: C
STATIC PRESSURE: 50 PSIG
RESIDUAL PRESSURE: 40 PSIG
PITOT PRESSURE: 40 PSI
FLOW: 1643 GPM
OUTLET COEFFICIENT: 0.9
RESIDUAL @ 1000 GPM: 46.0 PSI
NOTE: PERFORM CONFIRMING FLOW TEST TO OBTAIN CURRENT DATA
SPRINKLER DESIGN DEMAND
DENOTES LIGHT HAZARD AREA
SUPPRESSION SYSTEM TYPE WET PIPE
DESIGN DENSITY 0.10 GPM PER SQ FT
REQUIRED COVERAGE AREA 1,500 SQ FT
MAXIMUM COVERAGE PER SPRINKLER 225 SQ FT
OUTSIDE HOSE STREAM DEMAND 250 GPM
DURATION OF SUPPLY 60 MINUTES
K-FACTOR 5.6
DENOTES ORDINARY HAZARD AREA
SUPPRESSION SYSTEM TYPE WET PIPE
DESIGN DENSITY 0.20 GPM PER SQ FT
REQUIRED COVERAGE AREA 2,500 SQ FT
MAXIMUM COVERAGE PER SPRINKLER 130 SQ FT
OUTSIDE HOSE STREAM DEMAND 250 GPM
DURATION OF SUPPLY 60 MINUTES
K-FACTOR 8.0
ESTIMATED SPRINKLER DEMAND: 195 GPM @ 40.2 PSI
A. PROVIDE AN AUTOMATIC WET PIPE FIRE SPRINKLER SYSTEM AS SHOWN FOR ALL BUILDING AREAS.
B. ANY SPRINKLER PIPES, APPURTENANCES, AND FIRE SPRINKLER EQUIPMENT SHOWN ARE GENERIC.
THEY ARE SHOWN ONLY FOR DESIGN INTENT, TO VERIFY CLEARANCE, AND PROVIDE GENERAL PIPE
ROUTING. ALL ASPECTS OF THE DESIGN AND INSTALLATION SHALL BE PROVIDED BY THE
CONTRACTOR.
C. THE ENGINEER'S CALCULATIONS PROVIDED ON THIS SHEET FOR THE FIRE PROTECTION SYSTEMS ARE UTILIZED TO DETERMINE THE ADEQUACY OF THE FIRE WATER SUPPLY. THE FIRE SPRINKLER
CONTRACTOR SHALL PROVIDE A COMPLETE BUILDING FIRE SUPPRESSION SYSTEM WET PIPE
SPRINKLER SYSTEM CALCULATIONS AND PROVIDE ALL ASSOCIATED SHOP DRAWINGS.
D. COORDINATE THE LOCATION OF RISERS, DRAINS, TEST CONNECTIONS, AND OTHER SPRINKLER
SYSTEM COMPONENTS WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL
PORTIONS OF THE BUILDING
E. PROVIDE PIPE HANGERS, SEISMIC BRACING, FLEXIBLE AND RIGID COUPLINGS, AND SEISMIC SEPARATIONS ASSEMBLIES WHERE REQUIRED ON ALL WET PIPE SYSTEM PIPING IN ACCORDANCE
WITH SPECIFICATIONS AND NFPA 13.
F. SEE ARCHITECTURAL DRAWINGS FOR ROOM FINISH SCHEDULE AND ROOM USE. SEE
ARCHITECTURAL REFLECTED CEILING PLANS FOR THE LOCATION OF ALL CEILING-MOUNTED
DEVICES. FIELD VERIFY AND COORDINATE THE LOCATIONS OF ALL SYSTEM COMPONENTS
INCLUDING PIPING, ALARMS, DRAINS, TEST CONNECTIONS, ETC. WITH ARCHITECTURAL,
STRUCTURAL, MECHANICAL, AND ELECTRICAL EQUIPMENT WITHIN THE BUILDING.
G. PROVIDE SLEEVES AND ESCUTCHEONS FOR ALL PENETRATIONS THROUGH WALLS OR FLOORS THAT MIGHT INCLUDE DRILLING THROUGH CONCRETE, METAL, SHEETROCK, OR OTHER MATERIALS. FIELD
VERIFY APPROXIMATE WALL AND FLOOR PENETRATIONS SHOWN ON THE PLANS. SEAL ALL
PENETRATIONS IN RATED SEPARATION TO MEET THE MINIMUM FIRE RATING OF THE WALL OR
FLOOR.
H. PROVIDE ACCESS DOORS AND SIGNAGE WHERE ACCESS TO CONCEALED SPRINKLER EQUIPMENT, VALVES, AND CONTROLS LOCATED IN WALLS OR ABOVE CEILINGS IS REQUIRED.
I. PROVIDE SCHEDULE 40 BLACK STEEL FOR THE WET PIPE SYSTEMS.
J. THESE DOCUMENTS DEPICT PERFORMANCE LEVEL ENGINEERING DESIGN CRITERIA TO BE UTILIZED
AS GUIDANCE FOR THE PLANNING AND DESIGN OF THE FIRE SPRINKLER SYSTEM BY THE
CONTRACTOR'S QFPE. PROVIDE COMPLETE DOCUMENTS FOR REVIEW AND APPROVAL FROM THE
ENGINEER OF RECORD AND THE DFPE (MDO) TO INSTALLATION . INCLUDE IN THE SHOP DRAWINGS
AND CALCULATIONS ANY ADDITIONAL EQUIPMENT NECESSARY TO COMPLETE THE INSTALLATION
AND COMPLY WITH THE STANDARD OUTLINED IN THESE DRAWINGS AND IN THE DESIGN
SPECIFICATIONS.
K. FOR AREAS SHOWN, THE CONTRACTOR SHALL PROVIDE A HYDRAULICALLY DESIGNED SPRINKLER SYSTEM, DESIGNED AND INSTALLED IAW WITH THE LATEST EDITION OF UFC 3-600-01, NFPA 13, AND
THE SPECIFICATIONS TO PROVIDE COVERAGE SHOWN AT THE DENSITIES INDICATED. SYSTEM
DEMAND SHALL BE ON THE MOST HYDRAULICALLY DEMANDING AREA EXCEPT AS MODIFIED PER UFC
3-600-01. CALCULATIONS SHALL CLEARLY DEMONSTRATE HOW THE MOST HYDRAULICALLY
DEMANDING AREA WAS DETERMINED. HOSE STREAM SHALL BE PROVIDED BY THE DOMESTIC
WATER SYSTEM AND HOSE STREAM ALLOWANCE AS INDICATED SHALL NOT BE ADDED TO THE
SYSTEM DEMAND. CONTRACTOR SHALL PERFORM CONFIRMING FLOW TEST AND USE DATA
OBTAINED FOR ALL HYDRAULIC CALCULATIONS.
L. CONTRACTOR SHALL COORDINATE LOCATION OF SPRINKLER HEADS, DRAIN VALVES, VALVE
CABINETS, TEST HEADERS, AND ALL PIPING WITH ALL OTHER TRADES IN BUILDING CONTRACT. SHOP DRAWINGS SHALL SHOW COORDINATION WITH THE HVAC AND DOMESTIC WATER PIPING, INCLUDING
ELEVATIONS WHERE FIRE PROTECTION PIPING CROSSES HVAC AND DOMESTIC PIPING.
M. ALL SPRINKLER PIPING SHALL BE PITCHED FOR DRAINAGE OF SYSTEM. PROVIDE AND INSTALL DRAIN VALVES AND WASTE LINES FOR ALL SPRINKLERS AS REQUIRED BY CODE. END WASTE LINE OVER NEAREST FLOOR DRAIN. MULTIPLE DRAINS MAY BE NECESSARY DUE TO ELEVATION CHANGES IN
THIS PROJECT.
N. A FLOW SWITCH AND SUPERVISED ZONE OS&Y VALVE SHALL BE PROVIDED FOR EACH SPRINKLER
ZONE. ONE INSPECTOR TEST DRAIN CONNECTION SHALL BE PROVIDED PER ZONE TO TEST THE
OPERATION OF THE FLOW SWITCH AND ALARM SYSTEM. TEST CONNECTION SHALL BE LOCATED AT
THE MOST HYDRDAULICALLY REMOTE POINT.
O. PROVIDE SPRINKLER GUARDS FOR SPRINKLER HEADS THAT WILL BE EXPOSED.
P. PROVIDE FIRE EXTINGUISHERS IN ACCORDANCE WITH UFC 3-600-01 AND NFPA 10.
A ----------
ACC AIR COOLED CHILLER
AD AIR DEVICE
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AHU AIR HANDLING UNIT
AL ACOUSTICAL LINING
AS AIR SEPARATOR
AFMS AIR FLOW MEASURING
STATION
B ----------
BOD BOTTOM OF DUCT
BOP BOTTOM OF PIPE
C ----------
C CONDENSATE
CFM CUBIC FEET PER MINUTE
CH CHILLER
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
D ----------
DB DRY BULB
DFPE DESIGNATED FIRE
PROTECTION ENGINEER
DOAS DEDICATED OUTDOOR
AIR SYSTEM
DX DIRECT EXPANSION
E ----------
EA EXHAUST AIR
EAL EXHAUST AIR LOUVER
ECU EVAPORATIVE COOLING UNIT
EF EXHAUST FAN
ERU ENERGY RECOVERY UNIT
ET EXPANSION TANK
F ----------
FC FLEXIBLE CONNECTION
FCU FAN COIL UNIT
FD FIRE DAMPER
DO FAIL OPEN
FPM FEET PER MINUTE
G ----------
GR GLYCOL RETURN
GS GLYCOL SUPPLY
H ----------
HC HEATING COIL
HP HEAT PUMP
HPS HIGH PRESSURE STEAM
HVU HEAT AND VENT UNIT
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
I ----------
IHP INVERTER HEAT PUMP
L ----------
LPS LOW PRESSURE STEAM
LVR LOUVER
M ----------
MAU MAKEUP AIR UNIT
MVD MOTORIZED VOLUME
DAMPER
MPS MEDIUM PRESSURE STEAM
N ----------
NTS NOT TO SCALE
O ----------
OA OUTSIDE AIR
OAL OUTSIDE AIR LOUVER
P ----------
PFI PROVIDE, FURNISH, INSTALL
Q ----------
QFPE QUALIFIED FIRE PROTECTION
ENGINEER
R ----------
RA RETURN AIR
RH RADIANT HEATER
RFZ RADIANT FLOOR ZONE
S ----------
SA SUPPLY AIR
SM SNOW MELT MANIFOLD
T ----------
TA TRANSFER AIR
TWV TWO WAY VALVE
V ----------
VAV VARIABLE AIR VOLUME
VD VOLUME DAMPER
VFD VARIABLE FREQUENCY DRIVE
W ----------
WB WET BULB
Z ----------
ZSB ZONE SELECTOR BOX
AMENDMENT 0003
7/
2/
PUMP
MOTOR
DDC
OCCUPIED
UNOCCUPIED
H
N
CP-XX-S CP-XX-C
CONTACTOR PROVIDED
AND INSTALLED BY
ELECTRICAL CONTRACTOR
CURRENT TRANSFORMER
BY CONTROLS
SUBCONTRACTOR
CIRCUIT BREAKER
BY ELECT
POINTS LIST
TYPE TYPE DESCRIPTION UNITS TREND ALARM TOTALIZE
C O
N
TR
O
LL
ER
N
ET
W
O R
K
IN
PU
TS
AI IN PHW-T HOT WATER SUPPLY TEMPERATURE DEG F X
BI IN WH-S WATER HEATER STATUS OFF/ON
X X
XX X
BI IN CP-S RCP-1 STATUS OFF/ON XX X
BI OUT CP-C RCP-1 COMMAND START/STOP X
SOFTWARE BO OCCUPIED COMMAND OCCUPIED/UNOCCUPIED X
RCP-1
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
P-601
AI
R
M
AN
L
EA
D
ER
SH
IP
S C
H O
O L
FA
C
IL
IT
Y M
O
BI
LE
D
IS
TR
IC
T
R .R
EI
C
H
R .R
EI
C
H
W .K
N
AP
P
R .S
M
IT
H
M
AR
C H
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
F2
-M
EC
H
.rv t
M H
F2
EG
LI
N A
IR
F
O R
C E
BA
SE
, F L
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
PL
U
M
BI
N G
S C
H
ED
U
LE
S
M
AR
K D
AT
E
BF
P
SC
H
ED
U
LE
, P R
V, R
V, E
T, C
O N
ST
AN
T
PR
IM
AR
Y
PLUMBING FIXTURE SCHEDULE
SYM Family DESCRIPTION CW HW W V FCO-2 Floor Cleanout Cast Iron Adjustable Floor Cleanout w/Round Top 2" FCO-4 Floor Cleanout Cast Iron Adjustable Floor Cleanout w/Round Top 4"
FD Floor Drain - Round 5" strainer, 3" drain, trap primer connection 3" P-1 Water Closet - Wall Mounted - Manual Flush Valve Toilet, wall hung, vitreous china, elongated syphon jet flush action bowl, 2-1/8" fully glazed internal trapway, 10" x 12" large water surface, high efficiency 1.28 gal per flush, 1-1/2" top spud, for use with exposed flush valve.
1" 4" 2"
P-1A Water Closet - Wall Mounted - Manual Flush Valve Toilet, wall hung, vitreous china, elongated syphon jet flush action bowl, 2-1/8" fully glazed internal trapway, 10" x 12" large water surface, high efficiency 1.28 gal per flush, 1-1/2" top spud, for use with exposed flush valve. ABA compliant
1" 4" 2"
P-2 Water Closet - Floor Mounted - Manual Flush Valve Toilet, floor mounted, vitreous china, elongated syphon jet flush action bowl, 2-1/8" fully glazed internal trapway, 10" x 12" large water surface, high efficiency 1.28 GPF, 1-1/2" top spud with condensate channel and bolt caps, for use with exposed flush valve.
1" 3" 2"
P-3 Urinal - Wall Mounted - Manual Flush Valve Urinal, wall hung for flush valve, vitreous china, wash out flush action, 0.47L (0.125 gal.) per flush extended sides for privacy, integral flush spreader, open trap, wall hanger, 2" (50mm) outlet, connecting flange with gasket and bolts, 3/4" (19mm) top spud. For use with exposed flush valve.
3/4" 2" 1 1/2"
P-3A Urinal - Wall Mounted - Manual Flush Valve Urinal, wall hung for flush valve, vitreous china, wash out flush action, 0.47L (0.125 gal.) per flush extended sides for privacy, integral flush spreader, open trap, wall hanger, 2" (50mm) outlet, connecting flange with gasket and bolts, 3/4" (19mm) top spud. For use with exposed flush valve. ABA compliant.
3/4" 2" 1 1/2"
P-4 Lavatory - Oval Countersunk oval vitreous white china sink installed in a plastic laminate countertop. Faucets shall be 4” centerset washerless unit with single lever, aerator, and pop-up waste stopper. Provide a 1-1/2” OD tailpiece.
1/2" 1/2" 1 1/4" 1 1/4"
P-4A Lavatory - Oval Countersunk oval vitreous white china sink installed in a plastic laminate countertop. Faucets shall be 4” centerset washerless unit with single lever, aerator, and pop-up waste stopper. Provide a 1-1/2” OD tailpiece. ABA compliant.
1/2" 1/2" 1 1/4" 1 1/4"
P-5 Lavatory - Wall Mounted Wall Mounted, vitreous white china sink. Faucet shall be 4” centerset washerless unit with single lever, aerator, and pop-up waste stopper, 0.5 gpm flowrate. Provide a 1-1/2” OD tailpiece. ADA/ABA compliant.
1/2" 1/2" 1 1/4" 1 1/4"
P-6 Sink Kitchen-Double Dual compartment, 18 gauge stainless steel, self-rimming sink and sound deadening material on bottom and sides. Faucet shall be 2.2 gpm with a washerless top deck mounted model with single lever control, swing spout gooseneck with aerator, hose, and sprayer with diverter, integral stops, and garbage disposal.
1/2" 1/2" 1 1/2" 1 1/4"
P-7 Shower Stall - Rectangular Ceramic tile type, barrier free, cast brass body pressure/temp balance valve, integral stops, single lever handle, wall/hand shower, 5ft metal hose. Provide with 2.5 gpm max flowrate showerhead
1/2" 1/2" 1 1/2" 1 1/2"
P-8 Single Cooler w Bottle Filler 4.75 gph, wall hung, bubbler style, air cooled condensing unit with water filtration unit, single level unit with bottle filler attachment and wall carrier.
1/2" 1 1/4" 1 1/4"
P-9 Ice Maker Box 1/4 turn brass valve, 3-1/4” W x 4” H x 2-1/2” D box, 5” W x 6” H faceplate. Provide dual check backflow preventer at fixture
1/2"
P-10 Sink - Mop - Faucet Corner floor mounted Terrazzo mop sink, 24” x 24” x 12”Portland cement and marble chips, black/white finish w/ integral stainless steel drain. Faucet shall be wall mounted, chrome finished, 2.2 gpm flowrate, dual lever handles with 4” straight faucet spout w/ aerator, and integral vacuum breaker and stops.
1/2" 1/2" 1 1/2" 1 1/4"
P-11 Frost Proof Wall Hydrant 8” wall thickness, keyed handle, stainless steel casing, 3/4" inlet and outlet. 3/4" TP Trap Primer with Valve TRAP PRIMER
WCO Wall Cleanout Watts Drainage CO-440-RD wall cleanout with two-piece expandable cleanout plug, stainless steel access cover, and vandal proof stainless steel screw.
2"
WHA WATER HAMMER ARRESTOR Copper body, EPDM seals and O-rings, polypropylene piston, and NPT hex brass adapter end connections for easy installation. ASSE and ANSI approved, PDI certified, and IAPMO listed. Maximum Working Pressure: 150psi (10.6 bar).
DOMESTIC WATER HEATER SCHEDULE
MARK COMMENTS LOCATION CAPACITY
INPUT
BTU/HR
RECOVERY CAP GPH
(80 DEG RISE)
STORAGE
TEMPERATURE
DCW
DIA.
DHW
DIA.
NG
DIA.
MIN NG
PRESSURE
MAX NG
PRESSURE VENT DIA
WH-1 NATURAL GAS WATER HEATER MECH 100.00 gal 150,000 223 140 °F 1 1/2" 1 1/2" 3/4" 4.4" W.C. 14" W.C. 3"
HOT WATER RECIRCULATION PUMP SCHEDULE
MARK LOCATION TYPE
FLOW HEAD SPEED
ELECTRICAL
HP V/P/F
RCP-1 128 HVAC DIFFERENTIAL TEMPERATURE ACTIVATED 10 GPM 10.00 ftH2O 1725 1/8 115/1/60
DOMESTIC EXPANSION TANK SCHEDULE
MARK TYPE SYSTEM VOLUME MIN ACCEPT VOL PRE-CHARGE
ET-3 FULL ACCEPTANCE BLADDER DOMESTIC HOT WATER 2.0 gal 1.0 gal 12.00 psi
NTS1
PLUMBING CONTROLS - DOMESTIC
WATER HEATER CONTROLS
BACKFLOW PREVENTER SCHEDULE
MARK LOCATION SYSTEM SIZE
DESIGN
FLOW
PRESSURE DROP
(PSI)/@GPM
BFP-1 128 HVAC Hydronic Chilled Water Return 1" 20 GPM 5 BFP-2 128 HVAC Hydronic Hot Water Return 1" 20 GPM 5
AMENDMENT 0003
7/
2/
SYSTEM 1 SCHEMATIC - CHILLED WATER SYSTEM - AIR COOLED CHILLER W/ CONSTANT PRIMARY PUMPING
CHILLER CONTROL:
THE CHILLER SHALL START AND MAINTAIN WATER TEMPERATURE CONTROL THROUGH THE
LOCAL CHILLER CONTROL PANEL FURNISHED WITH THE CHILLER. CHILLERS
WILL ONLY BE ENABLED TO OPERATE IN "AUTO" UPON THE FOLLOWING CONDITIONS:
A. CHILLER IS SCHEDULED ON BY BAS
B. THERE ARE NO ACTIVE ALARMS THAT INITIATE A SHUTDOWN REPORTED TO BAS AND OR CHILLER PANEL
C. THERE IS A CALL FOR COOLING FROM THE BAS
D. CHILLED WATER FLOW IS VERIFIED BY THE BAS AND OR CHILLER PANEL
UPON A CALL FOR COOLING [IF ANY COOLING CONTROL VALVE (CCV) IS AT LEAST 15% OPEN FOR AT LEAST 2 MINUTES (ADJUSTABLE)], THE CHILLED WATER PUMP STARTS AND THE PUMP STATUS IS CONFIRMED "ON" VIA A CURRENT SENSOR IN THE BAS AND CHILLED WATER FLOW IS CONFIRMED THROUGH A FLOW SWITCH. AFTER FLOW IS
CONFIRMED, THE CHILLER STARTS.
CHILLED WATER SUPPLY TEMPERATURE (CHWST) RESET:
THE CHWST WILL HAVE A DEFAULT TEMPERATURE OF 44 DEGREE F. THE CHILLED WATER TEMPERATURE WILL BE RESET UPWARD WHEN THE CHILLED WATER RETURN TEMP TRANSMITTER (TT-1-01) DETECTS A TEMPERATURE BELOW THE SETPOINT OF 56 DEG F. THE CHWST RESET ROUTINE IS STARTED AND CONTINUES RESETTING CHWST UPWARD (46 DEGREE F) UNTIL THE CHWRT HAS REACHED THE SETPOINT. THE TEMPERATURE RESET ROUTINE SHALL INCLUDE A DIFFERENTIAL OR TIME DELAY TO PREVENT THE RESET ROUTINE FROM HUNTING. THE TEMPERATURE RESET SETPOINT TEMPERATURE WILL REMAIN UNTIL THE CHWRT IS ABOVE THE SETPOINT AT WHICH THE CHWST WILL BE LOWERED UNTIL THE 44 DEGREE F SETPOINT IS MET. THE CHWST RESET WILL NOT INCREASE AND SHALL BE RESET TO 44 DEGREE F WHEN THE RETURN AIR RELATIVE HUMIDITY RISES ABOVE 55% AS REPORTED FROM THE
BAS.
CHILLED WATER PUMP CONTROL:
THE CHW PUMPS ARE SET IN A LEAD/LAG CONFIGURATION, AND THE LEAD PUMP WILL BE BASED ON RUN TIME. WHEN THE LEAD PUMP HAS OPERATED FOR A SET AMOUNT OF TIME, THE LAG PUMP WILL BECOME THE LEAD PUMP (VICE
VERSA).
THE CHW PUMP STARTS UPON A CALL FOR COOLING PER THE ABOVE CHILLER SEQUENCES. THE CHW PUMP OPERATES CONTINUOUSLY WHEN THE CHILLER IS RUNNING. THE CHW PUMP PROVIDES A CONSTANT FLOW THROUGH THE CHILLER (SEE MECHANICAL SCHEDULE). AN ALARM IS INITIATED WHEN PUMP FAILURE IS DETECTED VIA A MOTOR CURRENT SWITCH AND OR FLOW SWITCH. UPON FAILURE OF LEAD PUMP, THE LAG PUMP AUTOMATICALLY STARTS. VFDU'S SHALL BE USED FOR SOFT STARTING AND BALANCING PURPOSES.
THE CHILLED WATER PUMP SHALL BE STARTED AND STOPPED WITH THE CHILLER.
TIME DELAY OPERATION SHALL BE PROVIDED AS REQUIRED TO ALLOW THE CHILLER TO PERFORM AN ORDERLY
SHUTDOWN WHEN THE DDC SYSTEM DE-ENERGIZES A CHILLER.
WHEN THE CHILLER IS DE-ENERGIZED, CHW PUMP SHALL CONTINUE TO OPERATE UNTIL THE CHILLER PERFORMS AN
ORDER SHUTDOWN.
SYSTEM 1 - SEQUENCE OF OPERATIONS
ACC-1
PANEL 1-02
CHILLER
CONTROLCR
1-02
CT
SE
T
PO
IN
T (A
DJ
ST
AR
T / S
TO
P
ST
AT
US
AL
AR
M
/T
RO
UB
LE
NC
FS
NC
CHWR
CHWP-1
PI
1-01
1-02
PI
NC
NC
CHWP-2
1-03
PI
1-04
PI
MAKEUP WATER
FROM DCW
PI
5-01 5-02
PIPRV SETTING
8.5 PSIG
12 PSIG
TANK PRECHARGE
NC
NC
QUICK FILL
BYPASS
RELIEF VALVE
30 PSIG
ROUTE 1" RELIEF LINE, FROM PRESSURE
RELIEF VALVE, TO NEAREST FLOOR DRAIN.
BFP-1
ET-1
FINAL CHARGE PRESSURE TO
BE DETERMINED DURING T&B
CHWR
LINE SIZE
AIR SEPARATOR
NC
ROUTE COPPER AIR BLEED LINE, FROM
AUTOMATIC AIR VENT, TO NEAREST FLOOR DRAIN.
AS-1
1-01
FT
CHWRCHWS
1-01
AGC
NC
1-01
TT
1-01
TI
1-02
TT
1-02
TI
VFDU
DR
IV
E
ST
AR
T/
ST
OP
DR
IV
E
SP
EE
D
AL
AR
M /T
RO
UB
LE
ST
AT
US
VFDU
DR
IV
E
ST
AR
T/
ST
OP
DR
IV
E
SP
EE
D
AL
AR
M /T
RO
UB
LE
ST
AT
US
BT-1
ISOLATION
VALVE
(TYP)
FACTORY
PROVIDED
FLOW SWITCH
BFP AND PIPING ARE
SPECIFIED UNDER
DIVISION 22
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
M-701
AI
R
M
AN
L
EA
D
ER
SH
IP
S C
H O
O L
FA
C
IL
IT
Y
PR
O
JE
C T/
C O
N
TR
AC
T
D
ES
C R
IP
TI
O N
ID
EN
TI
FI
ER
PR
O
JE
C T/
C O
N
TR
AC
T
ID
EN
TI
FI
ER
IF
N
EE
D
ED
M O
BI
LE
D
IS
TR
IC
T R
.R
EI
C H
R .R
EI
C
H
W .K
N
AP
P
R .S
M
IT
H
M
AR
C H
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
F2
-M
EC
H
.rv t
M H
F2
EG
LI
N A
IR
F
O R
C E
BA
SE
, F L
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
SY
ST
EM
C
H
IL
LE
D
W
AT
ER
S
YS
TE
M
AI
R
C O
O
LE
D C
H
IL
LE
R
W / C
O N
ST
AN
T
PR
IM
AR
Y
PU
M
PI
N G
M
AR
K D
AT
E
BF
P
SC
H
ED
U
LE
, P R
V, R
V, E
T, C
O N
ST
AN
T
PR
IM
AR
Y
NTS1
HVAC CONTROLS - AIR COOLED CHILLER
W/ CONSTANT PRIMARY - SEQUENCE
AMENDMENT 0003
7/
2/
| MHF20005C-003-Sheet |
| MHF20005C-006-Sheet |
| MHF20005CD101-Sheet |
| MHF20005CS101-Sheet |
| MHF20005CS502-Sheet |
| MHF20005CS503-SHEET-ANSI D 22x34 |
| MHF20005CG501-Sheet |
| MHF20005- FX001 - FIRE SUPPRESSION LEGEND.pdf |
| Sheets |
| FX001 - FIRE SUPPRESSION LEGEND |
| M-701 - SYSTEM 1 - CHILLED WATER SYSTEM - AIR COOLED CHILLER W/ CONSTANT PRIMARY PUMPING |
| P-601 - PLUMBING SCHEDULES |
| MHF20005 - P-601 - PLUMBING SCHEDULES.pdf |
| Sheets |
| FX001 - FIRE SUPPRESSION LEGEND |
| M-701 - SYSTEM 1 - CHILLED WATER SYSTEM - AIR COOLED CHILLER W/ CONSTANT PRIMARY PUMPING |
| P-601 - PLUMBING SCHEDULES |
| MHF20005 - M-701 - SYSTEM 1 - CHILLED WATER SYSTEM - AIR COOLED CHILLER W- VARIABLE PRIMARY PUMPING.pdf |
| Sheets |
| FX001 - FIRE SUPPRESSION LEGEND |
| M-701 - SYSTEM 1 - CHILLED WATER SYSTEM - AIR COOLED CHILLER W/ CONSTANT PRIMARY PUMPING |
| P-601 - PLUMBING SCHEDULES |
| MHF20005-STRC01 - Sheet - S-301 - FOUNDATION SECTIONS.pdf |
| Sheets |
| S-301 - FOUNDATION SECTIONS |
| S-501 - TYPICAL STRUCTURAL DETAILS |
| MHF20005-STRC01 - Sheet - S-501 - TYPICAL STRUCTURAL DETAILS.pdf |
| Sheets |
| S-301 - FOUNDATION SECTIONS |
| S-501 - TYPICAL STRUCTURAL DETAILS |
File details come from the government source that posted it. Updated .