W9127821R0012 Submittal Register.pdf

PDF 62 KB Posted

Attached to
Provide Prime Power, Soto Cano AB, Honduras
Solicitation number
W9127821R0012
Issued by

About this file

This submittal register outlines the required submittals for a contract to provide prime power services at Soto Cano Air Base in Honduras for the Department of the Army Corps of Engineers Engineering District Mobile. Key submittals include shop drawings for pad-mounted transformers and underground structures, product data for transformers, cables, joints, and terminations. Test reports are required for cable qualification, arc proofing, and field acceptance checks. Certificates must be provided for cable installers, concrete and steel poles, wood poles and crossarms, and transformer efficiencies. Operation and maintenance manuals and test schedules are also included as submittal requirements.

View the file

Other files

File Type Posted
W9127821R0012 For Information Only- JTFB Power Station Project As-Builts.pdf PDF
W9127821R0012 Submittals Procedures for Prime Power.pdf PDF
W9127821R0012 For Information Only- Fuel Piping Plan.pdf PDF
W9127821R0012 OEBGD Vol. 4-HAZMAT.pdf PDF
W9127821R0012 Base Access Requirements.pdf PDF
W9127821R0012 For Information Only- 2MW PV Solar Farm Project (As_Builts).pdf PDF
W9127821R0012 OEBGD Vol. 3-Water.pdf PDF
W9127821R0012 Overseas Environmental Bassline Guidance Document (OBEGD).pdf PDF
W9127821R0012 Reglamento para el control de emisiones generadas por fuentes fijas.pdf PDF
W9127821R0012 OEBGD Vol. 2-Air.pdf PDF
W9127821R0012 DBA Certification.pdf PDF
W9127821R0012 For Information Only- Fifth Unit Installation As-Builts.PDF PDF
W9127821R0012 For Information Only- Power Plant Stacks As-Builts.pdf PDF
W9127821R0012 Liquid-Filled Transformer Instruction and Maintenance Manual.pdf PDF
W9127821R0012 For Information Only- Controller with BOM.pdf PDF
W9127821R0012 OEBGD Vol. 1-Conservation.pdf PDF
W9127821R0012 SF-33.pdf PDF
W9127821R0012 152738 kV Vacuum Recloser Descriptive Bulletin.pdf PDF
W9127821R0012 OEBGD Vol. 5-Waste.pdf PDF
W9127821R0012 Virtual Site Visit-Prime Power-Soto Cano.pdf PDF
W9127821R0012 For Information Only- PV Farm Specifications 08-14-2019.pdf PDF
W9127821R0012 For Information Only- Generator Switchyard Plan.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 1 OF 4 PAGES

FY-21 PRIME POWER, SOTO CANO AIR BASE, HONDURAS

01 33 00 SD-01 Preconstruction Submittals

1.9 G CDSubmittal Register

26 12 19.00 40 SD-02 Shop Drawings

1.4.1 GPad-Mounted Transformer

Drawings

SD-03 Product Data

2.1.1 GPad-Mounted Transformers

SD-06 Test Reports

3.3.1 GAcceptance Checks And Tests

SD-07 Certificates

GTransformer Losses

SD-09 Manufacturer’s Field

Reports

2.3.2 GDesign Tests

2.3.3 GRoutine and Other Tests

SD-10 Operation and Maintenance

Data

1.5.1 GTransformer(s)

SD-11 Closeout Submittals

2.3.1 GTransformer Test Schedule

1.6 GWarranty

33 71 01 SD-03 Product Data

2.6Conductors

GG

2.5Insulators

2.2.2Concrete Poles

SUBMITTAL REGISTER

CONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:

SCHEDULE DATES

CONTRACTOR

ACTION

APPROVING AUTHORITY

A C T I V I T Y

N O

T R A N S M I T T A L

N O

S P E C

S E C T

DESCRIPTION

ITEM SUBMITTED

P A R A G R A P H

C L A S S I F I C A T I O N

G O V T

O R

A E

R E V W

R SUBMIT

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

A C T I O N

C O D E

DATE

OF

ACTION

DATE FWD

TO APPR

AUTH/

DATE RCD

FROM

CONTR

DATE FWD

TO OTHER

REVIEWER

DATE RCD

FROM OTH

REVIEWER

A C T I O N

C O D E

DATE

OF

ACTION

MAILED

TO

CONTR/

DATE RCD

FRM APPR

AUTH REMARKS

(a) (b) (c) (d) (e) (f) (g) (h) (i) (j) (k) (l) (m) (n) (o) (p) (q) (r)

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 2 OF 4 PAGES

33 71 01 Steel Poles

2.2.1Wood Poles

GNameplates

3.1.10 GPole Top Switch

2.17 GRecloser

2.18 GSectionalizer

2.13 GCutouts

2.15 GTransformer

2.19 GMetering Equipment

2.19.3 GMeters

2.12 GSurge Arresters

GCapacitors

GVoltage Regulator

2.8Guy Strand

2.10Anchors

SD-05 Design Data

2.2.2 GConcrete Poles

GSteel Poles

3.1.4.2 GPower-Installed Screw

Foundations

SD-06 Test Reports

1.5.4Wood Crossarm Inspection

Report

1.5.4.1 GField Test Plan

3.6 GField Quality Control

1.5.3 GGround Resistance Test Reports

SUBMITTAL REGISTER

CONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:

SCHEDULE DATES

CONTRACTOR

ACTION

APPROVING AUTHORITY

A C T I V I T Y

N O

T R A N S M I T T A L

N O

S P E C

S E C T

DESCRIPTION

ITEM SUBMITTED

P A R A G R A P

A S S I F I C A T I O N

G O V T

O R

A E

R E V W

R SUBMIT

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

A C T I O N

C O D E

DATE

OF

ACTION

DATE FWD

TO APPR

AUTH/

DATE RCD

FROM

CONTR

DATE FWD

TO OTHER

REVIEWER

DATE RCD

FROM OTH

REVIEWER

A C T I O N

C O D E

DATE

OF

ACTION

MAILED

TO

CONTR/

DATE RCD

FRM APPR

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 3 OF 4 PAGES

33 71 01 3.6.3 GMedium-Voltage Preassembled

Cable Test

3.6.4 GSag and Tension Test

3.6.5 GLow-Voltage Cable Test

3.6.7Acceptance Checks and Tests

SD-07 Certificates

2.2.2 GConcrete Poles

GSteel Poles

2.2.1 GWood Poles

2.3.1 GWood Crossarms

2.15.1 GTransformer Efficiencies

SD-09 Manufacturer’s Field

Reports

1.6 GOperation and Maintenance

Manuals

1.6.1 GOperation and Maintenance

Manuals

GTransformer Test Schedule

GRoutine and Other Tests

SD-10 Operation and Maintenance

Data

1.6 GOperation and Maintenance

Manuals

1.6.1 GOperation and Maintenance

Manuals

33 71 02 SD-02 Shop Drawings

SUBMITTAL REGISTER

CONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:

SCHEDULE DATES

CONTRACTOR

ACTION

APPROVING AUTHORITY

A C T I V I T Y

N O

T R A N S M I T T A L

N O

S P E C

S E C T

DESCRIPTION

ITEM SUBMITTED

P A R A G R A P

A S S I F I C A T I O N

G O V T

O R

A E

R E V W

R SUBMIT

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

A C T I O N

C O D E

DATE

OF

ACTION

DATE FWD

TO APPR

AUTH/

DATE RCD

FROM

CONTR

DATE FWD

TO OTHER

REVIEWER

DATE RCD

FROM OTH

REVIEWER

A C T I O N

C O D E

DATE

OF

ACTION

MAILED

TO

CONTR/

DATE RCD

FRM APPR

SUBMITTAL FORM,Jan 96 PREVIOUS EDITION IS OBSOLETE PAGE 4 OF 4 PAGES

33 71 02 2.2.1 GAluminum conductors

1.5.1 GPrecast underground structures

SD-03 Product Data

2.5 GMedium voltage cable

2.7 GMedium voltage cable joints

2.6 GMedium voltage cable

terminations

2.14.2.1 GPrecast concrete structures

2.14.2.4Sealing Material

3.5.3Pulling-In Irons

2.14.3 GManhole frames and covers

2.14.4 GHandhole frames and covers

2.14.7 GComposite/fiberglass handholes

2.15 GCable supports

SD-06 Test Reports

2.20.2 GMedium voltage cable

qualification and production tests

3.18.1 GField Acceptance Checks and

Tests

2.20.1 GArc-proofing test

SD-07 Certificates

GCable splicer/terminator

1.5.2 GCable Installer Qualifications

SUBMITTAL REGISTER

CONTRACT NO.

TITLE AND LOCATION CONTRACTOR

CONTRACTOR:

SCHEDULE DATES

CONTRACTOR

ACTION

APPROVING AUTHORITY

A C T I V I T Y

N O

T R A N S M I T T A L

N O

S P E C

S E C T

DESCRIPTION

ITEM SUBMITTED

P A R A G R A P

A S S I F I C A T I O N

G O V T

O R

A E

R E V W

R SUBMIT

APPROVAL

NEEDED

BY

MATERIAL

NEEDED

BY

A C T I O N

C O D E

DATE

OF

ACTION

DATE FWD

TO APPR

AUTH/

DATE RCD

FROM

CONTR

DATE FWD

TO OTHER

REVIEWER

DATE RCD

FROM OTH

REVIEWER

A C T I O N

C O D E

DATE

OF

ACTION

MAILED

TO

CONTR/

DATE RCD

FRM APPR