This solicitation is for construction services for the Advanced Munitions Technology Complex at Eglin Air Force Base in Florida. The scope of work includes construction of the Complex for Agile Processing of Energetics, Advanced Processing facilities consisting of six bunkers totaling 2,948 square feet. It also includes the CAPE Explosive Machining Facility containing three explosive machining bunkers and a staging building totaling 4,035 square feet. Additional facilities are the Advanced Dynamics Chamber Facility of 10,247 square feet and the Advanced Energetics Research Laboratory Facility of 11,137 square feet. The last facility is an Explosive Storage Facility to accommodate hazard class 1.1D storage of 40,000 pounds net explosive weight, designed similar to an Igloo Munitions Storage module. The solicitation number is W9127820R0093 and was issued by the Department of the Army Corps of Engineers Engineering District Mobile.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W9127820R0093 JA Brand Name Spec - Overly Door.pdf | ||
| W9127820R0093 JA Brand Name Spec (HVAC).pdf | ||
| AM03.pdf | ||
| AM02.pdf | ||
| AM01.pdf | ||
| Site Visit Sign In.pdf | ||
| VOL4.PDF | ||
| RTA DRAWINGS VOL 4.pdf | ||
| VOL3.PDF | ||
| VOL2.PDF | ||
| RTA DRAWINGS VOL 1.pdf | ||
| RTA DRAWINGS VOL 3.pdf | ||
| RTA DRAWINGS VOL 2.pdf | ||
| VOL1.PDF | ||
| EM 385-1-1.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE AL 36602
ADVANCED MUNITIONS TECHNOLOGY COMPLEX PH II
FTFA 043000
EGLIN AIR FORCE BASE, FLORIDA
OKALOOSA COUNTY
JULY 2020
MOBILE DISTRICT PROJECT CODE : MEF20050
SOLICITATION NUMBER : W9127819R0093
AMENDMENT NO. 0001
SAW BUNKER
MILL BUNKER
112X
LATHE BUNKER
1 Gal BP2
BUNKER
5 Gal BP BUNKER
5 Gal RAM
BUNKER
WEIGHING
BUNKER
FEM BUNKER
1 Gal BP1
BUNKER
1" GN2
4" VA
ST-07-07
ST-07-09
1 1/4" STM
1" GN2
1" CA
1" CR
4" VA
4" VA
1" CR
1" CA
1" GN2
1 1/4" STM
112' - 5"
112' - 6"
112' - 0"
113' - 4"
112' - 7"
113' - 5"
112' - 0"
PIPE RACK SUPPORTS SHOWN FOR
REFERENCE ONLY. SEE CIVIL FOR
LOCATION. SEE DETAILS A1 ON 01-
S-014 AND C1 ON 01-P-504.
1" CR
2" STM
PS-LS
PS-VS
PS-LS
PS-VS
PS-LS
PS-LS
PS-LS
PS-VS
PS-LS
PS-VSPS-LS
112' - 5"
2" STM
1 1/4" CA
113' - 7"
111' - 0"
1" GN2
1 1/4" CA
1" CR
4" VA
111' - 4"
AMTC PH 1
STAGING
BUILDING
AMTC PH 1
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S O
F
E N
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
AMENDMENT NO. 0001 -
8/18/2020 1:16:11 PM
'-0
B
F R
IN
K
C
M cA
F E
E G
F
A U
S T
12276407-P-1000050
-0
-P
-1
07-P-100
O V
E R
A L
L
P L
U M
B
IN
G P
L A
N
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
SCALE: 1" = 30'-0"A1
OVERALL PLUMBING PLAN
N
GENERAL NOTES:
1.
2.
3.
4.
5.
6.
7.
SEE SHEET 01-M-001 FOR MECHANICAL
NOTES, SYMBOLS AND ABBREVIATIONS.
PIPE ROUTING SHOWN IS APPROXIMATE, SEE
CIVIL UTILITY PLAN DRAWINGS FOR PIPE
SUPPORT LOCATIONS.
PIPING TO BUILDING 08 BUNKERS SHOWN FOR
REFERENCE ONLY. SEE 08-P-100.
PITCH STEAM, NITROGEN, AND COMPRESSED
AIR PIPING AT 1" PER 40' DOWN TOWARDS
BUNKERS.
PITCH CONDENSATE RETURN AND VACUUM
PIPING AT 1" PER 20' DOWN TOWARDS THE
STAGING BUILDING.
LISTED PIPE ELEVATIONS ARE RELATIVE TO THE
STAGING BUILDING'S FINISHED FLOOR
ELEVATION OF 100.00'. SEE SHEET 01-P-001 FOR
THE TRUE FINISHED FLOOR ELEVATION.
SEE SHEET 01-M-512 FOR STEAM PIPE
SUPPORTS. UNLESS OTHERWISE SHOWN, PIPE
SUPPORTS FOR STEAM PIPE SHALL BE GUIDE
TYPE (PS-G).
0 30' 60'
KEYED NOTES:
INSTALL VALVE IN EACH PIPE BRANCH TO THE
BUILDING 08 BUNKERS.
SPOT BOTTOM OF PIPE ELEVATION OF
STEAM, NITROGEN, AND COMPRESSED AIR.
SPOT BOTTOM OF PIPE ELEVATION OF
CONDENSATE RETURN AND VACUUM.
A
M E
N D
M
O D
IF
IE
D W
O R
K A
R E
A
/1
/2
| Sheets |
| 07-P-100 - OVERALL - PLUMBING PLAN |
File details come from the government source that posted it. Updated .