RTA DRAWINGS VOL 4.pdf
PDF 23 MB Posted
- Solicitation number
- W9127820R0093
About this file
This document provides details for a federal contract solicitation to construct facilities at Eglin Air Force Base in Florida. The solicitation seeks construction of six bunkers known as the Complex for Agile Processing of Energetics, Advanced Processing facilities totaling 2,948 square feet. It also involves constructing an Explosive Machining Facility containing three explosive machining bunkers and a staging building totaling 4,035 square feet. Additional facilities to be constructed include the Advanced Dynamics Chamber Facility of 10,247 square feet and the Advanced Energetics Research Laboratory Facility of 11,137 square feet. The solicitation also requires accommodating storage of 40,000 pounds of explosives in a storage facility similar to approved Igloo Munitions Storage modules. The issuing agency is the Department of the Army Corps of Engineers Engineering District Mobile.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| W9127820R0093 JA Brand Name Spec - Overly Door.pdf | ||
| W9127820R0093 JA Brand Name Spec (HVAC).pdf | ||
| AM03.pdf | ||
| AM02.pdf | ||
| AM01.pdf | ||
| AM01 DRAWINGS.pdf | ||
| Site Visit Sign In.pdf | ||
| VOL4.PDF | ||
| VOL3.PDF | ||
| VOL2.PDF | ||
| RTA DRAWINGS VOL 1.pdf | ||
| RTA DRAWINGS VOL 3.pdf | ||
| RTA DRAWINGS VOL 2.pdf | ||
| VOL1.PDF | ||
| EM 385-1-1.pdf |
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE AL 36602
ADVANCED MUNITIONS TECHNOLOGY COMPLEX PH II
FTFA 043000
EGLIN AIR FORCE BASE, FLORIDA
OKALOOSA COUNTY
JULY 2020
MOBILE DISTRICT PROJECT CODE : MEF20050
SOLICITATION NUMBER : W9127819R0093
VOLUME 4 OF 4
EG
LI
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:10:48 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0100050
-0
0- G-
00-G-010
ST
AN
D
AR
D D
ET
AI
LS
IN
D
EX
STANDARD DETAILS - FIRE PROTECTION DRAWING LIST
NUMBER NAME
01-FA501 FIRE ALARM & MNS SYMBOLS, LEGEND AND ABBREVIATIONS
01-FA601 FIRE ALARM DETAILS
01-FA602 FIRE ALARM RISER
01-FA603 FIRE ALARM MATRIX
01-FX501 FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS
01-FX601 FIRE SUPPRESSION ONE LINE DIAGRAMS
STANDARD DETAILS - STRUCTURAL DRAWING LIST
NUMBER NAME
01-S-001 GENERAL NOTES - SHEET 1
01-S-002 GENERAL NOTES - SHEET 2
01-S-003 LEGEND & ABBREVIATIONS
01-S-010 STANDARD CONCRETE DETAILS
01-S-011 STANDARD CONCRETE DETAILS
01-S-012 STANDARD CONCRETE DETAILS
01-S-013 STANDARD MASONRY DETAILS
01-S-014 PIPE RACK/LIGHTNING PROTECTION/ NITROGEN TANK FOUNDATION DETAILS
01-S-015 STANDARD STEEL DETAILS
01-S-016 STANDARD STEEL DETAILS
01-S-020 STANDARD FOUNDATION DETAILS
01-S-023 STANDARD ROOF DETAILS
01-S-030 PROTECTIVE CONSTRUCTION PLAN SHEET
01-S-031 ENHANCED BRACING PLANS AND DETAILS
01-S-033 PROTECTIVE CONSTRUCTION SECTIONS AND DETAILS
01-S-034 PROTECTIVE CONSTRUCTION SECTIONS AND DETAILS
01-S-035 PROTECTIVE CONSTRUCTION SECTIONS AND DETAILS
01-S-036 PROTECTIVE CONSTRUCTION SECTIONS AND DETAILS
STANDARD DETAILS - ARCHITECTURAL DRAWING LIST
NUMBER NAME
01-AG001 ARCHITECTURAL LEGEND & ABBREVIATIONS
01-AG002 ARCHITECTURAL GENERAL NOTES
01-AG003 ADA INFORMATION
01-A-201 MOCK UP PLANS
01-A-202 MOCK UP ELEVATIONS
01-A-203 MOCK UP SECTIONS
01-A-204 MOCK UP 3D VIEWS
01-A-361 SECTION DETAILS
01-A-362 SECTION DETAILS
01-A-363 SECTION DETAILS
01-A-364 SECTION DETAILS
01-A-365 SECTION DETAILS
01-A-461 PLAN DETAILS
01-A-462 EXTERIOR WALL DETAILS
01-A-511 PARTITION TYPE DETAILS
01-A-512 PARTITION TYPE DETAILS
01-A-521 PENETRATION DETAILS
01-A-522 DUCT PENETRATION DETAILS
01-A-561 CEILING DETAILS
01-A-581 ROOF DETAILS
01-A-582 ROOF DETAILS
01-A-583 ROOF DETAILS
01-A-584 ROOF DETAILS
01-A-585 ROOF DETAILS
01-A-586 ROOF DETAILS
01-A-587 ROOF DETAILS
01-A-591 CAGED LADDER DETAILS
01-A-611 DOOR DETAILS
01-A-612 DOOR DETAILS
01-A-613 DOOR DETAILS
01-A-614 HIGH SECURITY DOOR DETAILS
01-A-615 HIGH SECURITY DOOR DETAILS
01-A-616 DOOR DETAILS
01-A-621 BLAST DOOR DETAILS
01-A-624 BLAST DOOR DETAILS
01-A-627 BLAST DOOR DETAILS
01-A-628 BLAST DOOR DETAILS
01-A-661 LOUVER DETAILS
01-A-662 LOUVER DETAILS
01-A-761 MILLWORK DETAILS
01-A-762 CASEWORK DETAILS
01-A-765 EXTERIOR SIGNAGE DETAILS
01-A-771 FLOOR TRANSITION DETAILS
STANDARD DETAILS - ELECTRICAL DRAWING LIST
NUMBER NAME
01-E-001 ELECTRICAL SYMBOLS LEGEND
01-E-002 ELECTRICAL ABBREVIATIONS & GENERAL NOTES
01-E-003 ELECTRICAL CIRCUIT SIZING INFORMATION
01-E-501 ELECTRICAL POWER DETAILS
01-E-502 ELECTRICAL POWER DETAILS
01-E-503 OVERHEAD TRACK BUSWAY DETAILS
01-E-511 LIGHTING DETAILS
01-E-601 LIGHT FIXTURE SCHEDULE
01-EG501 GROUNDING DETAILS
01-EG502 GROUNDING DETAILS
01-EG503 GROUNDING DETAILS
01-EG800 AERL LIGHTNING PROTECTION COVERAGE
01-EG801 AERL LIGHTNING PROTECTION COVERAGE
01-EG820 CAPE LIGHTNING PROTECTION COVERAGE
01-EG830 ADC50 LIGHTNING PROTECTION COVERAGE
01-EG831 ADC50 LIGHTNING PROTECTION COVERAGE
01-EY501 SECURITY DETAILS
01-EY502 SECURITY DETAILS
STANDARD DETAILS - TELECOMMUNICATIONS DRAWING LIST
NUMBER NAME
01-T-001 COMMUNICATIONS LEGEND
01-T-501 COMMUNICATIONS DETAILS
01-T-502 COMMUNICATIONS DETAILS
STANDARD DETAILS - MECHANICAL DRAWING LIST
NUMBER NAME
01-M-001 MECHANICAL GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
01-M-002 MECHANICAL AERL SCHEDULE
01-M-004 MECHANICAL 07 CAPE SCHEDULE
01-M-005 MECHANICAL 08 CAPE SCHEDULE
01-M-006 MECHANICAL ADC-50 SCHEDULE
01-M-501 MECHANICAL DETAILS
01-M-502 MECHANICAL DETAILS
01-M-503 MECHANICAL DETAILS
01-M-504 MECHANICAL DETAILS
01-M-505 MECHANICAL DETAILS
01-M-506 MECHANICAL DETAILS
01-M-507 MECHANICAL DETAILS
01-M-508 MECHANICAL DETAILS
01-M-509 MECHANICAL DETAILS
01-M-510 MECHANICAL DETAILS
01-M-511 MECHANICAL DETAILS
01-M-512 MECHANICAL DETAILS
STANDARD DETAILS - PLUMBING DRAWING LIST
NUMBER NAME
01-P-001 PLUMBING GENERAL NOTES, SYMBOLS, AND ABBREVIATIONS
01-P-501 PLUMBING DETAILS
01-P-502 PLUMBING DETAILS
01-P-503 PLUMBING DETAILS
01-P-504 PLUMBING DETAILS
01-P-505 PLUMBING DETAILS
01-P-506 PLUMBING DETAILS
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:10:48 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0200050
-0
0- G-
00-G-020
C
IV
IL
/IN
FR
AS
TR
U
C
TU
R E
D R
AW
IN
G S
IN
D
EX
CIVIL/INFRASTUCTURE - GENERAL
NUMBER NAME
02-GC001 PROJECT LOCATION PLAN
02-GC002 CIVIL LEGEND SHEET
02-GC003 ACCESS AND SAFETY PLAN
02-GC004 ACCESS AND SAFETY NOTES 1 OF 2
02-GC005 ACCESS AND SAFETY NOTES 2 OF 2
02-GC006 STAGING AND LAYDOWN PLAN
02-GC007 STAGING AND LAYDOWN PLAN ENLARGED VIEW MAIN CAMPUS
02-GC008 STAGING AND LAYDOWN PLAN BID OPTION ADC-50 AREA
02-GC011 WORK ZONES - EXISTING QD ARCS
CIVIL/INFRASTUCTURE - SURVEY/MAPPING
NUMBER NAME
02-V-100 OVERALL EXISTING CONDITIONS PLAN
02-V-101 EXISTING CONDITIONS PLAN GRID 1
02-V-102 EXISTING CONDITIONS PLAN GRID 2
02-V-103 EXISTING CONDITIONS PLAN GRID 3
02-V-104 EXISTING CONDITIONS PLAN GRID 4
02-V-105 EXISTING CONDITIONS PLAN GRID 5
02-V-106 EXISTING CONDITIONS PLAN GRID 6
02-V-107 EXISTING CONDITIONS PLAN GRID 7
02-V-108 EXISTING CONDITIONS PLAN GRID 8
02-V-109 EXISTING CONDITIONS PLAN GRID 9
02-V-110 EXISTING CONDITIONS PLAN GRID 10
02-V-111 EXISTING CONDITIONS PLAN GRID 11
02-V-112 EXISTING CONDITIONS PLAN GRID 12
02-V-113 EXISTING CONDITIONS PLAN GRID 13
02-V-114 EXISTING CONDITIONS PLAN GRID 14
02-V-115 EXISTING CONDITIONS PLAN GRID 15
02-V-116 EXISTING CONDITIONS PLAN GRID 16
02-V-117 EXISTING CONDITIONS PLAN GRID 17
02-V-118 EXISTING CONDITIONS PLAN GRID 18
02-V-119 EXISTING CONDITIONS PLAN GRID 19
02-V-120 EXISTING CONDITIONS PLAN GRID 20
02-V-121 EXISTING CONDITIONS PLAN GRID 21
02-V-122 EXISTING CONDITIONS PLAN GRID 22
02-V-123 EXISTING CONDITIONS PLAN GRID 23
02-V-124 EXISTING CONDITIONS PLAN GRID 24
02-V-125 EXISTING CONDITIONS PLAN GRID 25
02-V-126 EXISTING CONDITIONS PLAN GRID 26
02-V-127 EXISTING CONDITIONS PLAN GRID 27
CIVIL/INFRASTUCTURE - GEOTECHNICAL
NUMBER NAME
02-B-100 GEOTECHNICAL PLAN
02-B-101 GEOTECHNICAL BORING LOGS AND NOTES 1
02-B-102 GEOTECHNICAL BORING LOGS AND NOTES 2
02-B-103 GEOTECHNICAL BORING LOGS AND NOTES 3
02-B-104 GETOTECNICAL BORING LOGS AND NOTES 4
02-B-105 GEOTECHNICAL BORING LOGS AND NOTES 5
02-B-106 GEOTECHNICAL BORING LOGS AND NOTES 6
02-B-107 GEOTECHNICAL BORING LOGS AND NOTES 7
02-B-108 GEOTECHNICAL BORING LOGS AND NOTES 8
02-B-109 GEOTECHNICAL BORING LOGS AND NOTES 9
CIVIL/INFRASTUCTURE - CIVIL DRAWINGS
NUMBER NAME
02-CU500 UTILITY NOTES
02-CU501 WATER SYSTEM DETAILS
02-CU502 WATER SYSTEM DETAILS
02-CU503 WATER SYSTEM DETAILS
02-CU504 WASTEWATER DETAILS
02-CU505 WASTEWATER DETAILS
02-CU506 WATER AND WASTEWATER DETAILS
02-CU509 LIFT STATION AND SANITARY SEWER DETAILS
CIVIL/INFRASTUCTURE - CIVIL DRAWINGS
NUMBER NAME
02-CS109 SITE PLAN GRID 9
02-CS111 SITE PLAN GRID 11
02-CS113 SITE PLAN GRID 13
02-CS117 SITE PLAN GRID 17
02-CS130 OVERALL PAVEMENT LAYOUT PLAN
02-CS132 BID OPTION AERL - PAVEMENT LAYOUT PLAN
02-CS134 BID OPTION EXPLOSIVE STORAGE - PAVEMENT LAYOUT PLAN
02-CS135 BID OPTION ADC-50 JOINT LAYOUT PLAN
02-CS136 CAPE BUNKERS ENLARGED PLAN 1
02-CS137 CAPE BUNKERS ENLARGED PLAN 2
02-CS138 CAPE BUNKERS ENLARGED PLAN 3
02-CS141 PAVEMENT JOINTING/ELEVATION PLAN
02-CS142 BID OPTION AERL - PAVEMENT ELEVATION PLAN
02-CS144 BID OPTION EXPLOSIVE STORAGE - PAVEMENT ELEVATION PLAN
02-CS145 BID OPTION ADC-50 - PAVEMENT ELEVATION PLAN
02-CS146 CAPE BUNKERS ENLARGED ELEVATION PLAN 1
02-CS147 CAPE BUNKERS ENLARGED ELEVATION PLAN 2
02-CS148 CAPE BUNKERS ENLARGED ELEVATION PLAN 3
02-CS151 BID OPTION PARKING
02-CS160 CAPE UTILITY PIPE RACK PLAN
02-CS161 BID OPTION EXPLOSIVE STORAGE SITE PLAN 1
02-CS162 BID OPTION EXPLOSIVE STORAGE SITE PLAN 2
02-CS163 BID OPTION NORTH ROAD SITE PLAN
02-CS500 PAVEMENT DETAILS 1 OF 4
02-CS501 PAVEMENT DETAILS 2 OF 4
02-CS502 PAVEMENT DETAILS 3 OF 4
02-CS503 PAVEMENT DETAILS 4 OF 4
02-CS504 ACCESS AND SAFETY DETAILS
02-CS505 SITE DETAILS
02-CS507 SITE DETAILS
02-CS509 FENCING AND GATES DETAILS
02-CS510 FENCING AND GATES DETAILS
02-CS512 UTILITY TRENCH DETAILS
02-CS513 MANHOLE DETAILS
02-CS514 TANK DETAILS
02-CS516 FILTER BOX - SOLIDS INTERCEPTOR 1
02-CG100 OVERALL GRADING PLAN
02-CG101 GRADING PLAN GRID 1
02-CG102 GRADING PLAN GRID 2
02-CG103 GRADING PLAN GRID 3
02-CG104 GRADING PLAN GRID 4
02-CG105 GRADING PLAN GRID 5
02-CG106 GRADING PLAN GRID 6
02-CG109 GRADING PLAN GRID 9
02-CG111 GRADING PLAN GRID 11
02-CG113 GRADING PLAN GRID 13
02-CG140 BID OPTION - ADC-50 STOCKPILE REMOVAL PLAN
02-CG151 BID OPTION PARKING GRADING PLAN
02-CG204 BID OPTION - NORTH ROAD GRADING PLAN
02-CG212 ADC-50 PERIMETER ROAD PROFILE STA 0+12.00 TO STA 7+18.07
02-CG213 EXPLOSIVE STORAGE ROAD STA 1+02.36 TO STA 5+00
02-CG214 EXPLOSIVE STORAGE ROAD STA 5+00 TO STA 7+50
02-CG215 EXPLOSIVE STORAGE ROAD STA 7+50 TO 9+13.87
02-CG501 EROSION CONTROL DETAILS 1 OF 3
02-CG502 EROSION CONTROL DETAILS 2 OF 3
02-CG503 EROSION CONTROL DETAILS 3 OF 3
02-CU100 OVERALL UTILITY PLAN
02-CU101 UTILITY PLAN GRID 1
02-CU102 UTILITY PLAN GRID 2
02-CU104 UTILITY PLAN GRID 4
02-CU105 UTILITY PLAN GRID 5
02-CU106 UTILITY PLAN GRID 6
02-CU109 UTILITY PLAN GRID 9
02-CU111 UTILITY PLAN GRID 11
02-CU112 UTILITY PLAN GRID 12
02-CU113 UTILITY PLAN GRID 13
02-CU114 UTILITY PLAN GRID 14
02-CU115 UTILITY PLAN GRID 15
02-CU120 UTILITY PLAN GRID 20
02-CU130 OVERALL CAPE UTILITY PLAN
02-CU200 SANITARY SEWER ALIGNMENT LAYOUT
02-CU203 SANITARY SEWER PROFILE
02-CU204 SANITARY SEWER PROFILE
02-CU206 SANITARY SEWER PROFILE
02-CU207 SANITARY SEWER PIPE & STRUCTURE TABLES
02-CU208 SANITARY SEWER PIPE & STRUCTURE TABLES
02-CU209 SANITARY SEWER PIPE & STRUCTURE TABLES
02-CU250 STORM DRAIN PROFILES 1
02-CU251 STORM DRAIN PROFILES 2
CIVIL/INFRASTUCTURE - CIVIL DRAWINGS
NUMBER NAME
02-CD099 GENERAL DEMOLITION NOTES
02-CD100 OVERALL DEMOLITION PLAN
02-CD101 DEMOLITION PLAN GRID 1
02-CD102 DEMOLITION PLAN GRID 2
02-CD103 DEMOLITION PLAN GRID 3
02-CD109 DEMOLITION PLAN GRID 9
02-CD112 DEMOLITION PLAN GRID 12
02-CD115 DEMOLITION PLAN GRID 15
02-CD116 DEMOLITION PLAN GRID 16
02-CD119 DEMOLITION PLAN GRID 19
02-CD120 DEMOLITION PLAN GRID 20
02-CD151 BID OPTION PARKING DEMOLITION PLAN
02-CS100 OVERALL SITE PLAN
02-CS101 SITE PLAN GRID 1
02-CS102 SITE PLAN GRID 2
02-CS104 SITE PLAN GRID 4
02-CS105 SITE PLAN GRID 5
02-CS106 SITE PLAN GRID 6
CIVIL/INFRASTUCTURE - LANDSCAPE
NUMBER NAME
02-LS100 OVERALL SEED & SOD PLAN
02-LS101 ENLARGED SEED & SOD PLAN
02-LS102 ENLARGED SEED & SOD PLAN
02-LS103 ENLARGED SEED & SOD PLAN
02-LS104 DETAIL LANDSCAPE PLAN
02-LS200 OVERALL SIGNAGE
02-LS201 SIGNAGE PLAN
02-LS202 SIGNAGE PLAN BID OPTION ADC-50
02-LS203 SIGNAGE PLAN
02-LS500 LANDSCAPE DETAILS
02-LS501 LANDSCAPE DETAILS
02-LS502 BID OPTION MONUMENTSIGN AND SIGNAGE DETAILS
CIVIL/INFRASTUCTURE - ELECTRICAL
NUMBER NAME
02-ES001 PRIMARY DISTRIBUTION SWITCHING DIAGRAM
02-ES002 UTILITY GRID PLAN
02-ES101 UTILITY PLAN GRID 1
02-ES102 UTILITY PLAN GRID 2
02-ES113 UTILITY PLAN GRID 13
02-ES115 UTILITY PLAN GRID 15
02-ES501 ELECTRICAL DETAILS
02-ES503 ELECTRICAL DETAILS
02-ES504 ELECTRICAL DETAILS
02-ES507 ELECTRICAL DETAILS
02-ES508 ELECTRICAL DETAILS
02-ES509 ELECTRICAL DETAILS
02-ES510 ELECTRICAL DETAILS
02-ES801 CATHODIC PROTECTION DETAILS
02-ES802 CATHODIC PROTECTION DETAILS
02-ES803 CATHODIC PROTECTION DETAILS
CIVIL/INFRASTUCTURE - ELECTRICAL GROUNDING
NUMBER NAME
02-EG171 SITE LIGHTNING PROTECTION PLAN - GRID 1
02-EG172 SITE LIGHTNING PROTECTION PLAN - GRID 2
02-EG174 SITE LIGHTNING PROTECTION PLAN - GRID 4
02-EG175 SITE LIGHTNING PROTECTION PLAN - GRID 5
02-EG176 SITE LIGHTNING PROTECTION PLAN - GRID 6
02-EG181 SITE LIGHTNING PROTECTION PLAN - GRID 11
02-EG183 SITE LIGHTNING PROTECTION PLAN - GRID 13
02-EG185 SITE LIGHTNING PROTECTION PLAN - GRID 15
02-EG187 SITE LIGHTNING PROTECTION PLAN - GRID 17
CIVIL/INFRASTUCTURE - TELECOMMUNICATIONS
NUMBER NAME
02-TS001 UTILITY GRID PLAN
02-TS002 TELECOMMUNICATIONS LEGEND
02-TS101 UTILITY PLAN GRID 1
02-TS102 UTILITY PLAN GRID 2
02-TS109 UTILITY PLAN GRID 9
02-TS113 UTILITY PLAN GRID 13
02-TS114 UTILITY PLAN GRID 14
02-TS115 UTILITY PLAN GRID 15
02-TS116 UTILITY PLAN GRID 16
02-TS120 UTILITY PLAN GRID 20
02-TS601 TELECOMMUNICATIONS TOPOLOGY
02-TS602 TELECOMMUNICATIONS HANDHOLE BUTTERFLY DETAILS
02-TS603 TELECOMMUNICATIONS HANDHOLE BUTTERFLY DETAILS
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:11:16 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0300050
-0
0- G-
00-G-030
AE
R
L
IN
D
EX
AERL - STRUCTURAL DRAWING LIST
NUMBER NAME
03-S-101 FOUNDATION PLAN
03-S-111 SLAB PLAN
03-S-121 ROOF FRAMING PLAN
03-S-131 WALL ELEVATION PLAN
03-S-201 WALL ELEVATIONS
03-S-202 WALL ELEVATIONS
03-S-203 WALL ELEVATIONS
03-S-204 WALL ELEVATIONS
03-S-205 WALL ELEVATIONS
03-S-206 WALL ELEVATIONS
03-S-207 WALL ELEVATIONS
03-S-208 WALL ELEVATIONS
03-S-209 WALL ELEVATIONS
03-S-210 WALL ELEVATIONS
03-S-211 WALL ELEVATIONS
03-S-601 WIND LOAD DIAGRAMS
AERL - ARCHITECTURAL DRAWING LIST
NUMBER NAME
03-A-010 AIR BARRIER PLAN AND SECTIONS
03-A-101 GROUND FLOOR PLAN
03-A-102 ROOF PLAN
03-A-151 REFLECTED CEILING PLAN
03-A-152 GROUND FLOOR - ACOUSTICAL PANEL LAYOUT
03-A-201 EXTERIOR BUILDING ELEVATIONS
03-A-202 EXTERIOR BUILDING ELEVATIONS
03-A-301 BUILDING SECTIONS
03-A-311 WALL SECTIONS
03-A-312 WALL SECTIONS
03-A-313 WALL SECTIONS
03-A-401 ENLARGED TOILET PLAN AND ELEVATIONS
03-A-402 GUARDRAIL ELEVATIONS
03-A-431 TRANSLUCENT WALL PANEL PLANS
03-A-432 TRANSLUCENT WALL PANEL DETAILS
03-A-433 TRANSLUCENT WALL PANEL DETAILS
03-A-501 PARTITION TYPES
03-A-551 DETAILS
03-A-582 CANOPY DETAILS
03-A-601 DOOR SCHEDULE, DOOR AND FRAME TYPES, LOUVER SCHEDULE AND TYPES
03-A-701 ROOM FINISH SCHEDULE
03-A-731 SIGNAGE PLANS
03-A-741 SIGNAGE SCHEDULE AND SIGN TYPES
03-A-742 SIGN TYPES
03-A-751 INTERIOR ELEVATIONS
03-A-752 INTERIOR ELEVATIONS
03-A-753 INTERIOR ELEVATIONS
03-A-754 INTERIOR ELEVATIONS
03-A-901 EQUIPMENT PLAN - AREA A
03-A-902 EQUIPMENT PLAN - AREA B
03-A-903 EQUIPMENT PLAN - AREA C
AERL - INTERIORS DRAWING LIST
NUMBER NAME
03-I-101 OVERALL FURNITURE PLAN
AERL - FIRE PROTECTION DRAWING LIST
NUMBER NAME
03-F-001 LIFE SAFETY NARRATIVE AND BUILDING CODE ANALYSIS
03-F-101 GROUND FLOOR LIFE SAFETY PLAN
03-FA101 FIRE ALARM GROUND FLOOR PLAN
03-FX101 FIRE SUPPRESSION GROUND FLOOR PLAN
AERL - PLUMBING DRAWING LIST
NUMBER NAME
03-P-601 PLUMBING SCHEDULES
03-P-602 PLUMBING SCHEDULES
03-P-610 GAS FLOW DIAGRAM
03-P-611 NATURAL GAS DIAGRAM
03-P-901 WASTE & VENT RISER ISOMETRIC
03-P-902 DOMESTIC WATER RISER ISOMETRIC
AERL - PLUMBING DRAWING LIST
NUMBER NAME
03-P-101 UNDERGROUND PLUMBING PLAN - AREA A
03-P-102 UNDERGROUND PLUMBING PLAN - AREA B
03-P-103 UNDERGROUND PLUMBING PLAN - AREA C
03-P-104 UNDERGROUND PLUMBING PLAN - AREA D
03-P-105 ABOVEGROUND PLUMBING PLAN - AREA A
03-P-106 ABOVEGROUND PLUMBING PLAN - AREA B
03-P-107 ABOVEGROUND PLUMBING PLAN - AREA C
03-P-108 ABOVEGROUND PLUMBING PLAN - AREA D
03-P-301 PLUMBING SECTIONS
03-P-501 PLUMBING DETAILS
AERL - MECHANICAL DRAWING LIST
NUMBER NAME
03-M-101 FIRST FLOOR - MECHANICAL PLAN - AREA A
03-M-102 FIRST FLOOR - MECHANICAL PLAN - AREA B
03-M-103 FIRST FLOOR - MECHANICAL PLAN - AREA C
03-M-104 FIRST FLOOR - MECHANICAL PLAN - AREA D
03-M-105 ROOF PLAN
03-M-106 ENLARGED MECHANICAL ROOM
03-M-301 MECHANICAL SECTIONS
03-M-302 MECHANICAL SECTIONS
03-M-303 MECHANICAL SECTIONS
03-M-304 MECHANICAL SECTIONS
03-M-305 MECHANICAL SECTIONS
03-M-306 MECHANICAL SECTIONS
03-M-307 MECHANICAL SECTIONS
03-M-308 MECHANICAL SECTIONS
03-M-501 MECHANICAL DETAILS
03-M-601 MECHANICAL SCHEDULES
03-M-602 MECHANICAL SCHEDULES
03-M-603 MECHANICAL SCHEDULES
03-M-604 MECHANICAL SCHEDULES
03-M-605 MECHANICAL SCHEDULES
03-M-610 CHILLED WATER FLOW DIAGRAM
03-M-611 HEATING WATER FLOW DIAGRAM
03-M-621 HVAC AIR FLOW DIAGRAM
03-M-622 HVAC AIR FLOW DIAGRAM
03-M-701 MECHANICAL CONTROLS LEGEND
03-M-702 MECHANICAL CONTROLS ARCHITECTURE
03-M-703 MECHANICAL CONTROL SCHEMATIC CHILLED WATER SYSTEM
03-M-704 MECHANICAL CONTROL SEQUENCE CHILLED WATER SYSTEM
03-M-705 MECHANICAL CONTROL POINTS SCHEDULE CHILLED WATER SYSTEM
03-M-706 MECHANICAL CONTROL SCHEMATIC HOT WATER SYSTEM
03-M-707 MECHANICAL CONTROL POINTS SCHEDULE HEATING HOT WATER SYSTEM
03-M-708 MECHANICAL CONTROL SCHEMATIC AIR HANDLING UNIT
03-M-709 MECHANICAL CONTROL POINTS SCHEDULE AIR HANDLING UNIT
03-M-710 MECHANICAL CONTROL SCHEMATIC VAV TERMINAL UNIT
03-M-711 MECHANICAL CONTROL SCHEMATIC HOOD TERMINAL UNIT
03-M-712 MECHANICAL CONTROL SCHEMATIC DUCTLESS SPLIT SYSTEM
03-M-713 MECHANICAL CONTROL SCHEMATIC EXHAUST FAN
03-M-714 MECHANICAL CONTROL SCHEMATIC SUPPLY FAN
03-M-715 MECHANICAL CONTROL SCHEMATIC UNIT HEATER
03-M-716 MECHANICAL CONTROL THERMOSTAT SCHEDULE
03-M-901 MECHANICAL/ELECTRICAL ROOM G109 ISOMETRIC
AERL - ELECTRICAL DRAWING LIST
NUMBER NAME
03-E-101 PROTECTIVE CONSTRUCTION PLAN
03-E-102 POWER PLAN
03-E-103 POWER PLAN - HVAC
03-E-104 ROOF POWER PLAN
03-E-120 LIGHTING CONTROLS PLAN
03-E-121 LIGHTING PLAN
03-E-151 GROUNDING PLAN
03-E-191 LABORATORY CABLE TRAY
03-E-201 ELEVATIONS
03-E-401 ENLARGED POWER PLANS
03-E-600 ELECTRICAL SCHEDULES
03-E-601 ELECTRICAL SCHEDULES
03-E-602 ELECTRICAL SCHEDULES
03-E-603 ELECTRICAL SCHEDULES
03-E-701 ONE-LINE DIAGRAM
03-EY101 SECURITY PLAN
AERL - TELECOMMUNICATIONS DRAWING LIST
NUMBER NAME
03-T-101 COMMUNICATIONS PLAN
03-T-102 PUBLIC ADDRESS AND AV PLAN
03-T-401 COMMUNICATIONS ENLARGED PLANS
03-T-701 COMMUNICATIONS RISER AND SCHEDULES
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:11:26 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0500050
-0
0- G-
00-G-050
EX
PL
O
SI
VE
S
TO
R
AG
E
IN
D
EX
EXPLOSIVE STORAGE - STRUCTURAL DRAWING LIST - BID OPTION
NUMBER NAME
05-S-001 GENERAL NOTES
05-S-002 SPECIAL INSPECTIONS
05-S-101 FOUNDATION PLAN
05-S-102 ROOF FRAMING PLAN
05-S-201 ELEVATIONS
05-S-202 ELEVATIONS
05-S-301 BUILDING SECTIONS
05-S-302 BUILDING SECTIONS
05-S-303 SECTIONS
05-S-501 TYPICAL DETAILS
05-S-701 DOOR FRAME ELEVATIONS
05-S-702 DOOR ELEVATIONS
05-S-703 DOOR SECTIONS
05-S-704 DOOR DETAILS
05-S-705 HIGH SECURITY HASP
EXPLOSIVE STORAGE - ELECTRICAL DRAWING LIST - BID OPTION
NUMBER NAME
05-E-101 ELECTRICAL PLAN
05-EG101 LIGHTNING PROTECTION SYSTEM
05-EG102 LIGHTNING PROTECTION SYSTEM
05-EG103 LIGHTNING PROTECTION SYSTEM
05-EG104 LIGHTNING PROTECTION SYSTEM
EXPLOSIVE STORAGE - TELECOMMUNICATION DRAWING LIST
NUMBER NAME
05-T-101 COMMUNICATIONS PLAN
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:11:53 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0700050
-0
0- G-
00-G-070
C
AP
E, E
XP
LO
SI
VE
M
AC
H
IN
IN
G
IN
D
EX
CAPE EXPLOSIVE MACHINING - STRUCTURAL DRAWING LIST
NUMBER NAME
07-S-101 OVERALL - FOUNDATION AND SLAB PLAN
07-S-201 SAW BUNKER PLANS AND ELEVATIONS
07-S-203 LATHE BUNKER PLANS AND ELEVATIONS
07-S-601 WIND LOAD DIAGRAMS
CAPE EXPLOSIVE MACHINING - FIRE PROTECTION DRAWING LIST
NUMBER NAME
07-F-001 LIFE SAFETY NARRATIVE AND BUILDING CODE ANALYSIS
07-F-101 OVERALL LIFE SAFETY PLAN
07-FA101 FIRE ALARM GROUND FLOOR PLAN
07-FX101 FIRE SUPPRESSION GROUND FLOOR PLAN
07-FX102 FIRE SUPPRESSION RISER DETAIL
CAPE EXPLOSIVE MACHINING - ARCHITECTURAL DRAWING LIST
NUMBER NAME
07-A-010 AIR BARRIER PLANS
07-A-011 AIR BARRIER SECTIONS
07-A-101 OVERALL FLOOR PLAN
07-A-102 OVERALL ROOF PLAN
07-A-121 BUNKER FLOOR PLANS AND ROOF PLANS
07-A-122 BUNKER FLOOR PLAN AND ROOF PLAN
07-A-151 OVERALL REFLECTED CEILING PLAN
07-A-162 BUNKER REFLECTED CEILING PLANS
07-A-202 BUNKER EXTERIOR BUILDING ELEVATIONS
07-A-303 BUNKER BUILDING SECTIONS AND WALL SECTION
07-A-312 WALL SECTIONS
07-A-351 SECTION DETAILS
07-A-601 DOOR SCHEDULE, DOOR AND FRAME TYPES
07-A-701 ROOM FINISH SCHEDULE
07-A-732 SIGNAGE PLANS
07-A-741 SIGNAGE SCHEDULE
07-A-902 EQUIPMENT PLANS AND SCHEDULES
CAPE EXPLOSIVE MACHINING - MECHANICAL DRAWING LIST
NUMBER NAME
07-M-102 SAW BUNKER MECHANICAL PLAN
07-M-104 LATHE BUNKER MECHANICAL PLAN
07-M-301 MECHANICAL SECTIONS
07-M-601 MECHANICAL SCHEDULES
07-M-602 MECHANICAL SCHEDULES
07-M-603 MECHANICAL SCHEDULES
07-M-610 STEAM PLANT DIAGRAM
07-M-611 STEAM FLOW DIAGRAM
07-M-621 HVAC AIR FLOW DIAGRAM
07-M-701 MECHANICAL CONTROLS LEGEND
07-M-702 MECHANICAL CONTROLS ARCHITECTURE
07-M-705 MECHANICAL CONTROL SCHEMATIC ROOF TOP UNIT
07-M-706 MECHANICAL CONTROL POINTS SCHEDULE ROOF TOP UNIT
CAPE EXPLOSIVE MACHINING - ELECTRICAL DRAWING LIST
NUMBER NAME
07-E-100 HAZARDOUS LOCATION AND PROTECTIVE CONSTRUCTION PLANS - BUNKER
07-E-104 POWER PLANS - BUNKER
07-E-106 HVAC POWER PLAN - BUNKER
07-E-122 LIGHTING AND CONTROLS PLANS - BUNKER
07-E-152 GROUNDING PLAN - BUNKER
07-E-200 OVERALL ELECTRICAL PIPE RACK CABLE TRAY ROUTING AND SECTIONS
07-E-600 ELECTRICAL SCHEDULES
07-E-601 ELECTRICAL SCHEDULES
07-E-602 ELECTRICAL SCHEDULES
07-E-603 ELECTRICAL SCHEDULES
07-E-701 ONE-LINE DIAGRAM
07-EY102 SECURITY AND SAFETY SYSTEM PLANS - BUNKER
CAPE EXPLOSIVE MACHINING - PLUMBING DRAWING LIST
NUMBER NAME
07-P-100 OVERALL - PLUMBING PLAN
07-P-103 SAW BUNKER PLUMBING PLAN
07-P-105 LATHE BUNKER PLUMBING PLAN
07-P-601 PLUMBING SCHEDULES
07-P-610 COMPRESSED AIR FLOW DIAGRAM
07-P-611 VACUUM FLOW DIAGRAM
CAPE EXPLOSIVE MACHINING - TELECOMMUNICATION DRAWING LIST
NUMBER NAME
07-T-102 COMMUNICATIONS PLANS - BUNKER
07-T-104 PUBLIC ADDRESS AND AV PLAN - BUNKER
07-T-401 COMMUNICATIONS RISER, ELEVATIONS, ENLARGED PLANS, AND SCHEDULES
CAPE EXPLOSIVE MACHINING - INTERIORS DRAWING LIST
NUMBER NAME
07-I-102 FURNITURE PLANS AND SCHEDULES
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:12:20 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0800050
-0
0- G-
00-G-080
C
AP
E, A
D
VA
N C
ED
P
R O
C
ES
SI
N
G
IN
D
EX
CAPE ADVANCED PROCESSING - STRUCTURAL DRAWING LIST
NUMBER NAME
08-S-101 OVERALL - FOUNDATION AND SLAB PLAN
08-S-201 1 GAL BP2 BUNKER PLANS AND ELEVATIONS - BID OPTION
08-S-202 5 GAL BP BUNKER PLANS AND ELEVATIONS - BID OPTION
08-S-203 5 GAL RAM BUNKER - PLANS AND ELEVATION - BID OPTION
08-S-204 1 GAL BP1 BUNKER PLANS AND ELEVATIONS - BID OPTION
08-S-205 FEM BUNKER PLANS AND ELEVATIONS - BID OPTION
08-S-206 WEIGHING BUNKER - PLANS AND ELEVATIONS - BID OPTION
08-S-601 WIND LOAD DIAGRAMS
CAPE ADVANCED PROCESSING - FIRE PROTECTION DRAWING LIST
NUMBER NAME
08-F-001 BUILDING CODE AND LIFE SAFETY CRITERIA
08-F-101 OVERALL LIFE SAFETY PLAN
08-FA101 FIRE ALARM GROUND FLOOR PLAN
08-FX101 FIRE SUPPRESSION GROUND FLOOR PLAN
CAPE ADVANCED PROCESSING - PLUMBING DRAWING LIST
NUMBER NAME
08-P-100 OVERALL - PLUMBING PLAN
08-P-101 1 GAL BP2 BUNKER & 5 GAL BP BUNKER - PLUMBING PLAN
08-P-102 GAL BP 1 BUNKER & FEM BUNKER - PLUMBING PLAN
08-P-103 5 GAL RAM BUNKER & WEIGHING BUNKER - PLUMBING PLAN
08-P-601 PLUMBING SCHEDULES
08-P-610 COMPRESSED AIR FLOW DIAGRAM
08-P-611 VACUUM FLOW DIAGRAM
CAPE ADVANCED PROCESSING - ELECTRICAL DRAWING LIST
NUMBER NAME
08-E-100 OVERALL HAZARDOUS LOCATION AND PROTECTIVE CONSTRUCTION PLAN
08-E-103 POWER PLANS
08-E-104 POWER PLANS
08-E-105 POWER PLANS - HVAC
08-E-106 POWER PLANS - HVAC
08-E-121 LIGHTING AND CONTROLS PLANS
08-E-122 LIGHTING AND CONTROLS PLANS
08-E-151 GROUNDING PLAN
08-E-152 GROUNDING PLAN
08-E-600 ELECTRICAL SCHEDULES
08-E-601 ELECTRICAL SCHEDULES
08-E-602 ELECTRICAL SCHEDULES
08-E-603 ELECTRICAL SCHEDULES
08-EY101 SECURITY AND SAFETY SYSTEM PLANS
08-EY102 SECURITY AND SAFETY SYSTEM PLANS
CAPE ADVANCED PROCESSING - MECHANICAL DRAWING LIST
NUMBER NAME
08-M-101 1 GAL BP2 BUNKER & 5 GAL BP BUNKER - MECHANICAL PLAN
08-M-102 1 GAL BP 1 BUNKER & FEM BUNKER MECHANICAL PLAN
08-M-103 5 GAL RAM BUNKER & WEIGHING BUNKER MECHANICAL PLAN
08-M-301 MECHANICAL SECTIONS
08-M-302 MECHANICAL SECTIONS
08-M-501 MECHANICAL DETAILS
08-M-601 MECHANICAL SCHEDULES
08-M-602 MECHANICAL SCHEDULES
08-M-610 STEAM FLOW DIAGRAM
08-M-611 STEAM FLOW DIAGRAM
08-M-621 HVAC AIR FLOW DIAGRAM
08-M-701 MECHANICAL CONTROLS LEGEND
08-M-702 MECHANICAL CONTROLS ARCHITECTURE
08-M-703 MECHANICAL CONTROL SCHEMATIC ROOF TOP UNIT
08-M-704 MECHANICAL CONTROL POINTS SCHEDULE ROOF TOP UNIT
08-M-705 MECHANICAL CONTROL SCHEMATIC EXHAUST FAN
CAPE ADVANCED PROCESSING - TELECOMMUNICATION DRAWING LIST
NUMBER NAME
08-T-101 COMMUNICATIONS PLANS
08-T-102 COMMUNICATIONS PLANS
08-T-103 PUBLIC ADDRESS AND AV PLAN
08-T-104 PUBLIC ADDRESS AND AV PLAN
CAPE ADVANCED PROCESSING - INTERIORS DRAWING LIST
NUMBER NAME
08-I-111 FURNITURE PLANS
08-I-112 FURNITURE PLANS
CAPE ADVANCED PROCESSING - ARCHITECTURAL DRAWING LIST
NUMBER NAME
08-A-010 AIR BARRIER PLAN AND SECTION
08-A-101 OVERALL GROUND FLOOR PLANS
08-A-102 OVERALL ROOF PLAN
08-A-111 ENLARGED FLOOR PLANS AND ROOF PLANS
08-A-112 ENLARGED FLOOR PLANS AND ROOF PLANS
08-A-113 ENLARGED FLOOR PLANS AND ROOF PLANS
08-A-151 OVERALL REFLECTED CEILING PLANS
08-A-161 REFLECTED CEILING PLANS
08-A-162 REFLECTED CEILING PLANS
08-A-201 EXTERIOR BUILDING ELEVATIONS
08-A-301 BUILDING SECTIONS AND WALL SECTION
08-A-351 SECTION DETAILS
08-A-601 DOOR SCHEDULE, DOOR AND FRAME TYPES
08-A-701 ROOM FINISH SCHEDULE
08-A-731 SIGNAGE PLANS
08-A-741 SIGNAGE SCHEDULE
08-A-901 EQUIPMENT PLANS AND SCHEDULES
08-A-902 EQUIPMENT PLANS AND SCHEDULES
N
AI
R
FO
RC
E
BA
SE
, F
LO
RI
DA
AD
VA
N C
ED
M
U N
IT
IO
N S
TE
C
H N
O
LO
G Y
C O
M
PL
EX
P
H
AS
E
II
PR
O
JE
C
T N
O . F
TF
A0
M
O
BI
LE
D
IS
TR
IC
T
M O
BI
LE
, A
LA
BA
M
A
Mobile District
US Army Corps of Engineers ®
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
N O
US
A
RM
Y
CO
RP
S O
F
EN
G
IN
EE
RS
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
AR
D P
AR
KW
AY
KA
N
SA
S C
IT
Y, M O
BU
RN
S
M cD
O
NN
EL
L
D
ES
IG
N
ED
B
Y:
D R
AW
N
B Y:
SB
M
T
BY
PL
O
T
SC
AL
E:
SI
ZE
" x
4"
FI
LE
N
AM
E:
C
KD
B Y:
PL
O
T D
AT
E:
D
AT
E:
SO
LI
C
IT
AT
IO
N N
U M
BE
R
PR
O
JE
C
T N
U M
BE
R
C
AD
D C
O D
E:
W
8-
-R
-0
FT
FA
M
EF
FTFA043000
JU
N
E, JU
N
E, 6/23/2020 5:12:47 PM
J.
M
AJ
OR
S
A.
S
NE
TH
EN
12276400-G-0900050
-0
0- G-
00-G-090
AD
C
-5
IN
D
EX
ADC-50 - ARCHITECTURAL DRAWING LIST
NUMBER NAME
09-A-010 AIR BARRIER PLAN
09-A-011 AIR BARRIER SECTIONS
09-A-101 GROUND FLOOR PLAN
09-A-102 ROOF PLAN
09-A-151 REFLECTED CEILING PLAN
09-A-152 REFLECTED CEILING PLAN - ACOUSTICAL PANEL LAYOUT
09-A-201 EXTERIOR BUILDING ELEVATIONS
09-A-202 EXTERIOR BUILDING ELEVATIONS
09-A-301 BUILDING SECTIONS
09-A-311 WALL SECTIONS
09-A-312 WALL SECTIONS
09-A-351 SECTION DETAILS
09-A-352 SECTION DETAILS
09-A-401 ENLARGED FLOOR PLAN
09-A-402 INTERIOR ELEVATIONS
09-A-403 ENLARGED FLOOR PLAN AND ELEVATIONS
09-A-404 ENLARGED TOILET PLAN AND ELEVATIONS
09-A-405 ENLARGED FLOOR PLAN AND ELEVATIONS
09-A-451 PLAN DETAILS
09-A-501 PARTITION TYPES
09-A-601 DOOR SCHEDULE, DOOR AND FRAME TYPES, LOUVER SCHEDULE AND LOUVER TYPES
09-A-611 DOOR DETAILS
09-A-701 ROOM FINISH SCHEDULE
09-A-731 SIGNAGE PLANS
09-A-741 SIGNAGE SCHEDULE AND SIGNAGE TYPES
09-A-901 EQUIPMENT PLAN
ADC-50 - FIRE PROTECTION DRAWING LIST
NUMBER NAME
09-F-001 LIFE SAFETY NARRATIVE AND BUILDING CODE ANALYSIS
09-F-101 OVERALL LIFE SAFETY PLAN
09-FA101 FIRE ALARM GROUND FLOOR PLAN
09-FX101 FIRE SUPPRESSION GROUND FLOOR PLAN
ADC-50 - INTERIORS DRAWING LIST
NUMBER NAME
09-I-101 OVERALL FURNITURE PLAN
ADC-50 - PLUMBING DRAWING LIST
NUMBER NAME
09-P-101 UNDERGROUND PLUMBING PLAN - AREA A
09-P-102 UNDERGROUND PLUMBING PLAN - AREA B
09-P-103 UNDERGROUND PLUMBING PLAN - AREA C
09-P-104 UNDERGROUND PLUMBING PLAN - AREA D
09-P-105 ABOVEGROUND PLUMBING PLAN - AREA A
09-P-106 ABOVEGROUND PLUMBING PLAN - AREA B
09-P-107 ABOVEGROUND PLUMBING PLAN - AREA C
09-P-108 ABOVEGROUND PLUMBING PLAN - AREA D
09-P-109 ENLARGED MECHANICAL ROOM
09-P-301 PLUMBING SECTIONS
09-P-501 PLUMBING DETAILS
09-P-601 PLUMBING SCHEDULES
09-P-602 PLUMBING SCHEDULES
09-P-610 COMPRESSED AIR FLOW DIAGRAM
09-P-611 NATURAL GAS DIAGRAM
09-P-901 PLUMBING WASTE & VENT RISER ISOMETRIC
09-P-902 PLUMBING DOMESTIC WATER RISER ISOMETRIC
ADC-50 - MECHANICAL DRAWING LIST
NUMBER NAME
09-M-101 FIRST FLOOR - HVAC PLAN- AREA A
09-M-102 FIRST FLOOR - HVAC PLAN - AREA B
09-M-103 FIRST FLOOR - HVAC PLAN - AREA C
09-M-104 HIGH ROOF PLAN
09-M-105 ENLARGED MECHANICAL ROOM
09-M-301 MECHANICAL SECTIONS
09-M-302 MECHANICAL SECTIONS
09-M-303 MECHANICAL SECTIONS
09-M-501 MECHANICAL DETAILS
09-M-502 MECHANICAL DETAILS
09-M-601 MECHANICAL SCHEDULES
09-M-602 MECHANICAL SCHEDULES
09-M-603 MECHANICAL SCHEDULES
09-M-610 HEATING WATER FLOW DIAGRAM
09-M-621 HVAC AIR FLOW DIAGRAM
09-M-701 MECHANICAL CONTROLS LEGEND
09-M-702 MECHANICAL CONTROLS ARCHITECTURE
09-M-703 MECHANICAL CONTROL SCHEMATIC HOT WATER SYSTEM
09-M-704 MECHANICAL CONTROL POINTS SCHEDULE HOT WATER SYSTEM
09-M-705 MECHANICAL CONTROL SCHEMATIC BLAST CHAMBER AIR HANDLING UNIT
09-M-706 MECHANICAL CONTROL POINT SCHEDULE BLAST CHAMBER AIR HANDLING UNIT
09-M-707 MECHANICAL CONTROL SCHEMATIC OBSERVATION AIR HANDLING UNIT
09-M-708 MECHANICAL CONTROL POINT SCHEDULE OBSERVATION AIR HANDLING UNIT
09-M-709 MECHANICAL CONTROL SCHEMATIC LAB AIR HANDLING UNIT
09-M-710 MECHANICAL CONTROL POINT SCHEDULE TEST LAB AIR HANDLING UNIT
09-M-711 MECHANICAL CONTROL SCHEMATIC VAV TERMINAL UNIT
09-M-712 MECHANICAL CONTROL SCHEMATIC DUCTLESS SPLIT SYSTEM
09-M-713 MECHANICAL CONTROL SCHEMATIC UNIT HEATER
09-M-714 MECHANICAL CONTROL SCHEMATIC SUPPLY FAN
09-M-715 MECHANICAL CONTROL SCHEMATIC EXHAUST FAN
09-M-716 MECHANICAL CONTROLS THERMOSTAT SCHEDULE
09-M-901 MECHANICAL ISOMETRIC
ADC-50 - ELECTRICAL DRAWING LIST
NUMBER NAME
09-E-100 HAZARDOUS LOCATION PLAN
09-E-101 PROTECTIVE CONSTRUCTION PLAN
09-E-102 POWER PLAN
09-E-103 POWER PLAN - HVAC
09-E-104 ROOF POWER PLAN
09-E-120 LIGHTING CONTROLS PLAN
09-E-121 LIGHTING PLAN
09-E-151 GROUNDING PLAN
09-E-501 ELECTRICAL DETAILS
09-E-600 ELECTRICAL SCHEDULES
09-E-601 ELECTRICAL SCHEDULES
09-E-602 ELECTRICAL SCHEDULES
09-E-701 ONE-LINE DIAGRAM
09-E-702 BLAST CHAMBER SYSTEM STATUS CONTROL PANEL
09-EP191 LABORATORY CABLE TRAY PLAN
09-EY101 SECURITY AND SAFETY SYSTEMS PLAN
ADC-50 - TELECOMMUNICATION DRAWING LIST
NUMBER NAME
09-T-101 COMMUNICATIONS PLAN
09-T-102 PUBLIC ADDRESS AND AV PLAN
09-T-401 COMMUNICATIONS ENLARGED PLANS
09-T-701 COMMUNICATIONS RISER AND SCHEDULES
ADC-50 - STRUCTURAL DRAWING LIST
NUMBER NAME
09-S-101 FOUNDATION PLAN
09-S-111 SLAB PLAN
09-S-121 ROOF FRAMING PLAN
09-S-131 WALL ELEVATION PLAN
09-S-132 WALL SECTION PLAN
09-S-201 WALL ELEVATIONS
09-S-202 WALL ELEVATIONS
09-S-203 WALL ELEVATIONS
09-S-204 WALL ELEVATIONS
09-S-205 WALL ELEVATIONS
09-S-206 WALL ELEVATIONS
09-S-207 WALL ELEVATIONS
09-S-208 WALL ELEVATIONS
09-S-209 WALL ELEVATIONS
09-S-210 WALL ELEVATIONS
09-S-521 FRAGMENT PLATE SECTIONS AND DETAILS
09-S-522 FRAGMENT PLATE SECTIONS AND DETAILS
09-S-523 BLAST DOOR SECTIONS
09-S-524 PORTHOLE SECTIONS AND DETAILS
09-S-525 WALL SECTIONS
09-S-526 WALL SECTIONS
09-S-527 MISCELLANEOUS SECTIONS
09-S-601 WIND LOAD DIAGRAMS
A
B
1 2
SEE SHEET 07-S-203
SEE SHEET 07-S-201
SEE CIVIL DRAWINGS FOR PIPE
RACK AND BARRIER WALL PLAN,
AND SEE 01-S-014/035 FOR DETAILS
BASE BID
SEE SHEET 08-S-101
BASE BID
SEE SHEET 08-S-101
BASE BID
SEE SHEET 08-S-101
BASE BID
SEE SHEET 08-S-101
BASE BID
SEE SHEET 08-S-101
BASE BID
SEE SHEET 08-S-101
BASE BID
CAPE 07 BUNKER PIPE RACK FOUNDATIONS, TYP.
CONTRACTOR SHALL ENSURE UTILITY RACK AND
FOUNDATION WILL BE PROVIDED TO THE SELECTED
BASE BID BUNKER.
BASE BID
CAPE 08 BUNKER PIPE RACK FOUNDATIONS, TYP.
CONTRACTOR SHALL ENSURE UTILITY RACK AND
FOUNDATION WILL BE PROVIDED TO THE
SELECTED BASE BID BUNKER.
BASE BID
SAW BUNKER
BASE BID
LATHE BUNKER
AMTC PH1
MILL BUNKER
AMTC PH1
STAGING BUILDING
PIPE RACK FDNS
FOR BID OPTION
SAW BUNKER
PIPE RACK FDNS
FOR BASE BID
LATHE BUNKER
PIPE RACK FDNS
FOR AMTC PH1
CAPE COMPLEX
1. SEE 01-S-001 THROUGH 01-S-003 FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS.
SEE 01-S-010 THROUGH 01-S-016 FOR STANDARD CONCRETE, MASONRY, AND STEEL DETAILS.
SEE 01-S-020 THROUGH 01-S-023 FOR STANDARD FOUNDATION AND ROOF DETAILS.
2. FLOOR DRAIN, TYP. SEE PLUMBING DRAWINGS.
3. TRENCH DRAIN, TYP. SEE PLUMBING DRAWINGS.
4. SEE 01-S-011 FOR TYPICAL EQUIP PAD DETAILS. COORD EQUIP PAD LOCATION, SIZE AND QUANTITY W/
ACTUAL EQUIP FURNISHED.
5. CJ-1 OR CJ-2, TYP. SEE 01-S-011 FOR SLAB JOINT AND VAPOR BARRIER DETAILS. CONTRACTOR SHALL
SUBMIT JOINT LAYOUT PLAN FOR APPROVAL.
6. SEE 01-S-020 FOR TYP VENEER LEDGE DETAILS, SEE WALL ELEVATIONS FOR PLAN DIMENSIONS.
7. SEE B2/01-S-012 FOR SLAB REINFORCING AT DOOR OPENINGS.
8. FOR OPENINGS 12 INCHES OR LESS, CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND
QUANTITY WITH OTHER DISCIPLINES. CONTRACTOR SHALL REVIEW AND CONFIRM ALL OPENINGS WITH
OTHER DISCIPLINES.
9. CONTRACTOR SHALL PROVIDE SOME ALLOWANCE IN BASE BID FOR UP TO (10) 6” DIAMETER SUPPLEMENTAL WALL PENETRATIONS TO BE COORDINATED WITH THE USERS DURING CONSTRUCTION. CONVENTIONAL CONSTRUCTION WALL PENETRATIONS MAY BE CORED WITH APPROVAL OF THE CONTRACTING OFFICER.
SUPPLEMENTAL AND CONVENTIONAL CONSTRUCTION WALL PENETRATIONS SHALL NOT BE MADE TO
PROTECTIVE CONSTRUCTION WALLS.
10. OPENINGS SHOWN ARE NOMINAL SIZE, AND MAY REQUIRE DIMENSIONAL ADJUSTMENT FOR ROUGH
OPENING SIZE.
11. FOR ROOF OPENING, PROVIDE SECURITY BARS PER STANDARD DETAILS AND MISCELLANEOUS FRAMING TO BRACE VENT. PROVIDE SECURITY BARS WHERE REQUIRED PER DETAILS A4/01-S-010 AND C5/01-S-035.
NOTES:
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S O
F
E N
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/25/2020 11:42:56 AM
A s in d ic a te d
P
M A
N
IS
C
M C
G E
E J.
S C
H M
ID
T
12276407-S-1010050
-0
-S
-1
07-S-101
O V
E R
A L L
F O
U N
D A
T
IO
N A
N D
S L A
B P
L A
N
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
NTSSCALE:A1
OVERALL FOUNDATION AND SLAB PLAN
WALL TYPE SCHEDULE
MARK
ACTUAL
THICKNESS
REINFORCEMENT
COMMENTS
VERTICAL DIRECTION HORIZONTAL DIRECTION
FLEXURAL FLEXURAL
SM8 7 5/8" #5@16" OC (2) #6@32" OC
N
SLAB ON GRADE SCHEDULE
MARK TYPE REINFORCEMENT COMMENTS
S12 12" CONCRETE #5@12" OC EW T&B
B3
07-S-201
B2
07-S-201
B4
07-S-201
25' - 4"
WF36SW16
8" 22' - 8" 8"
S12
B1
07-S-201
NOTE 6
NOTE 4
NOTE 7
NOTE 3
2' - 11 1/2"
A1
07-S-201
A3
07-S-201
A2
07-S-201
A4
07-S-201
W X
W X
W X
1/4" A36 PLATE
(GALV)
T/PLATE EL 119' - 0 1/4"
T/WALL EL 119' - 0"
ø
2' - 1 1/4"
/4
EQ EQ EQ EQ EQ
W X
1. SEE 01-S-001 THROUGH 01-S-003 FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS.
SEE 01-S-010 THROUGH 01-S-016 FOR STANDARD CONCRETE, MASONRY, AND STEEL DETAILS.
SEE 01-S-020 THROUGH 01-S-023 FOR STANDARD FOUNDATION AND ROOF DETAILS.
2. FLOOR DRAIN, TYP. SEE PLUMBING DRAWINGS.
3. TRENCH DRAIN, TYP. SEE PLUMBING DRAWINGS.
4. SEE 01-S-011 FOR TYPICAL EQUIP PAD DETAILS. COORD EQUIP PAD LOCATION, SIZE AND QUANTITY W/
ACTUAL EQUIP FURNISHED.
5. CJ-1 OR CJ-2, TYP. SEE 01-S-011 FOR SLAB JOINT AND VAPOR BARRIER DETAILS. CONTRACTOR SHALL
SUBMIT JOINT LAYOUT PLAN FOR APPROVAL.
6. SEE 01-S-020 FOR TYP VENEER LEDGE DETAILS, SEE WALL ELEVATIONS FOR PLAN DIMENSIONS.
7. SEE B2/01-S-012 FOR SLAB REINFORCING AT DOOR OPENINGS.
8. FOR OPENINGS 12 INCHES OR LESS, CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND
QUANTITY WITH OTHER DISCIPLINES. CONTRACTOR SHALL REVIEW AND CONFIRM ALL OPENINGS WITH
OTHER DISCIPLINES.
9. CONTRACTOR SHALL PROVIDE SOME ALLOWANCE IN BASE BID FOR UP TO (10) 6” DIAMETER SUPPLEMENTAL WALL PENETRATIONS TO BE COORDINATED WITH THE USERS DURING CONSTRUCTION. CONVENTIONAL CONSTRUCTION WALL PENETRATIONS MAY BE CORED WITH APPROVAL OF THE CONTRACTING OFFICER.
SUPPLEMENTAL AND CONVENTIONAL CONSTRUCTION WALL PENETRATIONS SHALL NOT BE MADE TO
PROTECTIVE CONSTRUCTION WALLS.
10. OPENINGS SHOWN ARE NOMINAL SIZE, AND MAY REQUIRE DIMENSIONAL ADJUSTMENT FOR ROUGH
OPENING SIZE.
11. FOR ROOF OPENING, PROVIDE SECURITY BARS PER STANDARD DETAILS AND MISCELLANEOUS FRAMING TO BRACE VENT. PROVIDE SECURITY BARS WHERE REQUIRED PER DETAILS A4/01-S-010 AND C5/01-S-035.
NOTES:
23' - 11 1/4"
" SM8SM8
T/SLAB EL 102' - 0"
7' - 9 5/8" 8' - 4" 7' - 9 5/8"
23' - 11 1/4"
T/STL EL 119' - 0"
T/SLAB EL 102' - 0"
T/SLAB EL 102' - 0"
23' - 11 1/4"
"SM8SM8
T/SLAB EL 102' - 0"
23' - 11 1/4"
SM8SM8
23' - 11 1/4"
" SM8SM8
T/SLAB EL 102' - 0"
T/WALL EL 119' - 0"
T/SLAB EL 102' - 0"
23' - 11 1/4"
1' - 0" 2' - 2 1/4"
"OPENINGS FOR PIPE
RACK, CONTRACTOR SHALL
COORDINATE WITH
PIPE RACK LAYOUT
T/WALL EL 119' - 0"
T/SLAB EL 102' - 0"
9' - 9 5/8" 4' - 4" 9' - 9 5/8"
23' - 11 1/4"
T/WALL EL 119' - 0"
T/SLAB EL 102' - 0"
23' - 11 1/4"
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/25/2020 11:42:56 AM
A s in d ic a te d
P
M A
N
IS
C
M C
G E
E J.
S C
H M
ID
T
12276407-S-2010050
-0
-S
-2
07-S-201
S A
W B
U N
K E
R P
L A
N S
A N
D E
L E
V A
T
IO
N S
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
SCALE: 1/8" = 1'-0"C1
SAW BUNKER - FOUNDATION AND SLAB PLAN
SCALE: 1/8" = 1'-0"C2
SAW BUNKER - ROOF FRAMING PLAN
0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
N N
SCALE: 1/8" = 1'-0"A1
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"B1
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"A4
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"A3
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"A2
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"B2
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"B3
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"B4
WALL OPENING ELEVATION
23' - 11 1/4"
7' - 9 5/8" 8' - 4" 7' - 9 5/8"
T/SLAB EL 96' - 0"
T/WALL EL 113' - 0" T/WALL EL 113' - 0"
T/SLAB EL 96' - 0"
23' - 11 1/4"
9' - 9 5/8" 4' - 4" 9' - 9 5/8"
T/SLAB EL 96' - 0"
T/WALL EL 113' - 0"
23' - 11 1/4"
T/STL EL 113' - 0"
T/SLAB EL 96' - 0"
23' - 11 1/4"
6' - 4 3/8" 1' - 0"
OPENINGS FOR PIPE
RACK, CONTRACTOR SHALL
COORDINATE WITH
PIPE RACK LAYOUT
23' - 11 1/4"
SM8SM8
T/SLAB EL 96' - 0"
23' - 11 1/4"
SM8SM8
T/SLAB EL 96' - 0"
23' - 11 1/4"
SM8SM8
T/SLAB EL 96' - 0"
23' - 11 1/4"
SM8SM8
T/SLAB EL 96' - 0"
B1
07-S-203
B2
07-S-203
B3
07-S-203
B4
07-S-203
WF36SW16
8" 22' - 8" 8"
S12
NOTE 4
NOTE 6
NOTE 7
NOTE 3
2' - 11 1/2"
/8
A1
07-S-203
A2
07-S-203
A3
07-S-203
A4
07-S-203
EQ EQ EQ EQ EQ
W X
W X
W X
1/4" A36 PLATE
(GALV)
T/PLATE EL 113' - 0 1/4"
T/WALL EL 113' - 0"
ø
3' - 5"1
W X
1. SEE 01-S-001 THROUGH 01-S-003 FOR GENERAL NOTES, LEGEND, AND ABBREVIATIONS.
SEE 01-S-010 THROUGH 01-S-016 FOR STANDARD CONCRETE, MASONRY, AND STEEL DETAILS.
SEE 01-S-020 THROUGH 01-S-023 FOR STANDARD FOUNDATION AND ROOF DETAILS.
2. FLOOR DRAIN, TYP. SEE PLUMBING DRAWINGS.
3. TRENCH DRAIN, TYP. SEE PLUMBING DRAWINGS.
4. SEE 01-S-011 FOR TYPICAL EQUIP PAD DETAILS. COORD EQUIP PAD LOCATION, SIZE AND QUANTITY W/
ACTUAL EQUIP FURNISHED.
5. CJ-1 OR CJ-2, TYP. SEE 01-S-011 FOR SLAB JOINT AND VAPOR BARRIER DETAILS. CONTRACTOR SHALL
SUBMIT JOINT LAYOUT PLAN FOR APPROVAL.
6. SEE 01-S-020 FOR TYP VENEER LEDGE DETAILS, SEE WALL ELEVATIONS FOR PLAN DIMENSIONS.
7. SEE B2/01-S-012 FOR SLAB REINFORCING AT DOOR OPENINGS.
8. FOR OPENINGS 12 INCHES OR LESS, CONTRACTOR SHALL COORDINATE SIZE, LOCATION, AND
QUANTITY WITH OTHER DISCIPLINES. CONTRACTOR SHALL REVIEW AND CONFIRM ALL OPENINGS WITH
OTHER DISCIPLINES.
9. CONTRACTOR SHALL PROVIDE SOME ALLOWANCE IN BASE BID FOR UP TO (10) 6” DIAMETER SUPPLEMENTAL WALL PENETRATIONS TO BE COORDINATED WITH THE USERS DURING CONSTRUCTION. CONVENTIONAL CONSTRUCTION WALL PENETRATIONS MAY BE CORED WITH APPROVAL OF THE CONTRACTING OFFICER.
SUPPLEMENTAL AND CONVENTIONAL CONSTRUCTION WALL PENETRATIONS SHALL NOT BE MADE TO
PROTECTIVE CONSTRUCTION WALLS.
10. OPENINGS SHOWN ARE NOMINAL SIZE, AND MAY REQUIRE DIMENSIONAL ADJUSTMENT FOR ROUGH
OPENING SIZE.
11. FOR ROOF OPENING, PROVIDE SECURITY BARS PER STANDARD DETAILS AND MISCELLANEOUS FRAMING TO BRACE VENT. PROVIDE SECURITY BARS WHERE REQUIRED PER DETAILS A4/01-S-010 AND C5/01-S-035.
NOTES:
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/25/2020 11:42:57 AM
A s in d ic a te d
P
M A
N
IS
C
M C
G E
E J.
S C
H M
ID
T
12276407-S-2030050
-0
-S
-2
07-S-203
L A
T H
E B
U N
K E
R P
L A
N S
A N
D E
L E
V A
T
IO
N S
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
SCALE: 1/8" = 1'-0"B1
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"B2
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"B3
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"B4
WALL OPENING ELEVATION
SCALE: 1/8" = 1'-0"A1
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"A2
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"A3
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"A4
WALL REINFORCEMENT ELEVATION
SCALE: 1/8" = 1'-0"C1
LATHE BUNKER - FOUNDATION AND SLAB PLAN
SCALE: 1/8" = 1'-0"C2
LATHE BUNKER - ROOF FRAMING PLAN
0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16'0 4' 8' 16'0 4' 8' 16'0 4' 8' 16'
0 4' 8' 16' 0 4' 8' 16'
NN
ROOF
GROUND FLOOR
A A
4WHERE WALL BELOW IS
WHERE WALL BELOW IS 5P
4P
PARAPET PER ARCH
3P
2WHERE ADJACENT ROOF IS
WHERE ADJACENT ROOF IS 3P
2P
3 2
TYPICAL BUNKER
T Y
P
"A
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/25/2020 11:42:58 AM
A s in d ic a te d
P
M A
N
IS
C
M C
G E
E J.
S C
H M
ID
T
12276407-S-6010050
-0
-S
-6
07-S-601
W
IN
D L
O A
D D
IA
G
R A
M S
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
1. REFER TO GENERAL NOTES FOR WIND LOADING DESIGN CRITERIA.
2. WIND PRESSURES ARE AT SERVICE LEVEL 0.6W PER ASCE 7 AND SHALL APPLY
NORMAL TO MEMBER SURFACE.
3. PLUS (+) AND MINUS (-) SIGNS INDICATE PRESSURES ACTING TOWARD AND AWAY
FROM SURFACE, RESPECTIVELY.
4. EACH COMPONENT SHALL BE DESIGNED FOR MAXIMUM POSITIVE AND NEGATIVE
PRESSURES.
5. "A" = 4 FEET.
COMPONENTS & CLADDING WIND PRESSURES (PSF)
WIND ZONE
ROOF DECK/SLAB WALLS
MAX MIN MAX MIN
1 +12.3 -30.3 - -
2 +27.7 -50.7 - -
3 +27.7 -50.7 - -
4 - - +24.4 -26.7
5 - - +24.4 -30.3
2P - - +28.8 -66.0
3P - - +28.8 -89.9
4P - - +28.8 -28.8
5P - - +28.8 -52.7
NTSSCALE:A1
WALL ELEVATION - WIND DIAGRAM
NTSSCALE:A2
PARAPET SECTION - WIND DIAGRAM
NTSSCALE:C1
WIND C&C ROOF PLAN
WIND LOADING NOTES:
ZONE E
A
A
A
ZONE D
A
A
A
A
A3
07-A-011
A3
07-A-011
GENERAL AIR BARRIER NOTES:
1.
2.
3.
4.
SEE SPECIFICATION 07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
TESTING FOR COMMISSIONING.
REFERENCE EXTERIOR DETAILS FOR CONTINUOUS AIR BARRIER.
ROOF AIR BARRIER SHALL BE CONCRETE ROOF DECK.
BUILDING IS UNDER 5,000 SF AND REQUIRES INSPECTION ONLY.
CONTINUOUS AIR BARRIER DEFINITION
(ALL AIR BARRIER SYSTEMS ON WALLS ARE FROM FLOOR TO
BOTTOM OF ROOF DECK OR CONNECT TO ROOF AIR BARRIER)
A
B
C
D
E
F
FULLY GROUTED CMU WALL WITH SPRAY APPLIED AIR
AND VAPOR BARRIER
CAST-IN-PLACE CONCRETE WALL WITH SPRAY APPLIED
AIR AND VAPOR BARRIER
ALUMINUM FRAME AND TRANSLUCENT FIBERGLASS
PANEL SYSTEM
CONCRETE ROOF
CAST-IN-PLACE CONCRETE FLOOR SLAB WITH 15 MIL
VAPOR BARRIER BELOW
PVC ROOFING MEMBRANE
AIR BARRIER ZONE LEGEND
ZONE D
FLOOR AREA =
WALL AREA =
ROOF AREA =
ZONE E
FLOOR AREA =
WALL AREA =
ROOF AREA =
AREAS LISTED BELOW ARE ROUGH ESTIMATES. CONTRACTOR SHALL
FIELD VERIFY ALL ZONE AREAS AND ADJUST CALCULATIONS FOR
MAXIMUM LEAKAGE CFM AS REQUIRED.
ALLOWABLE LEAKAGE RATE = 0.40 CFM/SF
AIR BARRIER LOCATION
522 SF
1,542 SF
522 SF
2,586 SF x 0.40 CFM/SF = 1,034 CFM
(MAX LEAKAGE)
522 SF
1,542 SF
522 SF
2,586 SF x 0.40 CFM/SF = 1,034 CFM
(MAX LEAKAGE)
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/16/2020 8:29:53 AM
A s in d ic a te d
B
K E
N N
A L
E Y
A . H
E R
M A
N J.
T O
P
12276407-A-0100050
-0
-A
-0
M
T O
L B
E R
T
07-A-010
A
IR
B A
R R
IE
R
P L A
N S
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
SCALE: 1/8" = 1'-0"A3
LATHE BUNKER AIR BARRIER PLAN
SCALE: 1/8" = 1'-0"A1
SAW BUNKER AIR BARRIER PLAN
0 4' 8' 16' 0 4' 8' 16'
N N
ROOM AREA SCHEDULE
NUMBER NAME NET AREA
111 SAW BUNKER 514 SF
113 LATHE BUNKER 514 SF
1,028 SF
GROSS AREA SCHEDULE
LEVEL AREA
LATHE BUNKER 642 SF
SAW BUNKER 642 SF
1,284 SF
GENERAL AIR BARRIER NOTES:
1.
2.
3.
4.
SEE SPECIFICATION 07 27 10.00 10 BUILDING AIR BARRIER SYSTEM
TESTING FOR COMMISSIONING.
REFERENCE EXTERIOR DETAILS FOR CONTINUOUS AIR BARRIER.
ROOF AIR BARRIER SHALL BE CONCRETE ROOF DECK.
BUILDING IS UNDER 5,000 SF AND REQUIRES INSPECTION ONLY.
CONTINUOUS AIR BARRIER DEFINITION
(ALL AIR BARRIER SYSTEMS ON WALLS ARE FROM FLOOR TO
BOTTOM OF ROOF DECK OR CONNECT TO ROOF AIR BARRIER)
A
B
C
D
E
F
FULLY GROUTED CMU WALL WITH SPRAY APPLIED AIR
AND VAPOR BARRIER
CAST-IN-PLACE CONCRETE WALL WITH SPRAY APPLIED
AIR AND VAPOR BARRIER
ALUMINUM FRAME AND TRANSLUCENT FIBERGLASS
PANEL SYSTEM
CONCRETE ROOF
CAST-IN-PLACE CONCRETE FLOOR SLAB WITH 15 MIL
VAPOR BARRIER BELOW
PVC ROOFING MEMBRANE
A
A
E
F
ZONE D
SAW BUNKER FLOOR LEVEL
102' - 0"
SAW BUNKER TOP OF MASONRY
119' - 0"
AIR BARRIER ZONE LEGEND
ZONE D
FLOOR AREA =
WALL AREA =
ROOF AREA =
ZONE E
FLOOR AREA =
WALL AREA =
ROOF AREA =
AREAS LISTED BELOW ARE ROUGH ESTIMATES. CONTRACTOR SHALL
FIELD VERIFY ALL ZONE AREAS AND ADJUST CALCULATIONS FOR
MAXIMUM LEAKAGE CFM AS REQUIRED.
ALLOWABLE LEAKAGE RATE = 0.40 CFM/SF
AIR BARRIER LOCATION
522 SF
1,542 SF
522 SF
2,586 SF x 0.40 CFM/SF = 1,034 CFM
(MAX LEAKAGE)
522 SF
1,542 SF
522 SF
2,586 SF x 0.40 CFM/SF = 1,034 CFM
(MAX LEAKAGE)
E G
L
IN
A
IR
F O
R C
E B
A S
E
F L
O R
ID
A
A D
V A
N C
E D
M U
N
IT
IO
N
S T
E C
H N
O L O
G Y
C O
M P
L E
X P
H A
S E
I I
P R
O J E
C T
N O
F
T F
A
M O
B
IL
E D
IS
T
R
IC
T M
O B
IL
E
A
L A
B A
M A
Mobile District
US Army Corps of
Engineers ®
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E A
P P
R N
O
U S
A R
M Y
C O
R P
S
G
IN
E E
R S
SHEET
IDENTIFICATION
1 2 3 4 5
D
C
B
A
FILE:
DATE:
W
A R
D P
A R
K W
A Y
K A
N S
A S
C
IT
Y
M O
B U
R N
S
M c D
O N
N E
L L
D E
S
IG
N E
D B
Y
D R
A W
N B
Y
S B
M T
B Y
P L
O T
S C
A L E
S
IZ
E x
F
IL
E N
A M
E
C K
D B
Y
P L
O T
D A
T E
D A
T E
S O
L
IC
IT
A
T
IO
N N
U M
B E
R
P R
O J E
C T
N U
M B
E R
C A
D D
C O
D E
W
-1
-R
-0
F T
F A
M E
F
FTFA043000
J U
N E
J U
N E
6/16/2020 8:29:54 AM
A s in d ic a te d
B
K E
N N
A L
E Y
A . H
E R
M A
N J.
T O
P
12276407-A-0110050
-0
-A
-0
M
T O
L B
E R
T
07-A-011
A
IR
B A
R R
IE
R
S E
C T
IO
N
S
C A
P E
E
X P
L O
S
IV
E M
A C
H
IN
IN
G
SCALE: 1/8" = 1'-0"A3
TYPICAL BUNKER AIR BARRIER SECTION
0 4' 8' 16'
B
FRAGMENTATION
BARRICADE WALLS (TYP)
RE:CIVIL
AMTC PHASE 1
STAGING BUILDING
AMTC PHASE 1
MILL BUNKER
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO SHEET AG001.
REFER TO STRUCTURAL DRAWINGS FOR CAST-IN-PLACE CONCRETE DIMENSIONS,
MASONRY WALL DIMENSIONS AND DOOR LOCATIONS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION REFER TO
PARTITION TYPES SHEET.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITE
CONDITIONS BEFORE BEGINNING WORK AND FABRICATION. THE OWNER
SHALL BE NOTIFIED IN WRITING IMMEDIATELY OF ANY DISCREPANCIES
OR INCONSISTENCIES. IN NO CASE SHALL DIMENSIONS BE SCALED OFF
PLANS, SECTIONS, OR DETAILS FROM THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 6 INCHES FROM FACE OF GYPSUM
BOARD FINISH WALL TO DOOR JAMB FACE. VERIFY THERE IS A PULL SIDE
MINIMUM 18 INCHES CLEAR FROM DOOR STRIKE TO INTERSECTING WALL FOR
ADA COMPLIANCE. NOTIFY OWNER FOR NON-COMPLIANCE BEFORE SETTING
DOOR FRAME AND WALL LOCATIONS.
CONTRACTOR SHALL COORDINATE AND PROVIDE ALL MILLWORK TRIM AND
INFILL PANELS AT ALL UNDERCOUNTER / CABINET LOCATIONS.
REFER TO FINISH SCHEDULE AND FINISH PLANS FOR ADDITIONAL FINISH
INFORMATION. ALL FLOOR FINISHES TO BE CONTINUOUS UNDER MILLWORK
AND EQUIPMENT UNLESS NOTED OTHERWISE.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING IN WALL FOR
TOILET FIXTURES, ACCESSORIES, EQUIPMENT, FLOOR AND WALL MOUNTED
TOILET PARTITIONS, AND COUNTERTOP MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD CONTROL JOINTS.
REFERENCE CIVIL DRAWINGS FOR EXTERIOR BOLLARD AND SPLASH BLOCK DETAILS.
FOR CONTROL JOINT DETAILS, REFER TO SHEET 01-A-512.
REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL, FINISH FACE
OF METAL STUD WALL, OR FACE…
This is the start of the file's text. The full file is on GovTribe.