RTA Drawings VOL2.pdf
PDF 20 MB Posted
- Solicitation number
- W9127820R0037
About this file
This package includes construction drawings and specifications for an aircraft hangar facility. Key details include constructing a 63,873 gross square foot hangar building with supporting facilities on Redstone Arsenal in Alabama. The hangar will include maintenance modules for UH-60 aircraft, administrative space, and company operations areas. Supporting structures comprise a fire pump building, site utilities, lighting, paving and landscaping. Construction will utilize type II-B building methods compliant with military standards. The solicitation seeks a construction contract valued between $25-100 million to be awarded under solicitation number W9127820R0037. The Army Corps of Engineers Mobile District will administer the contract.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| AM04.pdf | ||
| AM03 DRAWINGS.pdf | ||
| AM03.pdf | ||
| AM02.pdf | ||
| AM02 DRAWINGS.pdf | ||
| Redstone Aircraft PreBid Signin.pdf | ||
| AM01 DRAWINGS.pdf | ||
| AM01.pdf | ||
| EM 385-1-1.pdf | ||
| RTA Drawings VOL1.pdf | ||
| VOL4.PDF | ||
| VOL2.PDF | ||
| VOL1.PDF | ||
| VOL3.PDF |
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
US Army Corps of Engineers®
MOBILE DISTRICT
109 SAINT JOSEPH STREET
MOBILE AL 36602
AIRC FT AND FLIGHT EQUIPMENT BUILDING
REDSTONE ARSENAL, ALABAMA
MOBILE DISTRICT PROJECT CODE : MHY20008
SOLICITATION NUMBER: W9127820R0037
JUNE 2020
VOLUME 2 OF 2
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
G-002
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T J.
D
ES
IG
N
ER
J.
D
R
AW
N
J.
SU
BM
IT
TE
D
J.
C
H
EC
KE
R
M M
M M
M M
M M
M Y
YY
Y
W
8-
XX
-X
-X
XX
X
W
8-
XX
-X
-X
XX
X
M H
Y2
-G
-C M
.rv t M
H Y2
-G -C
M
.rv t
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
SH
EE
T
IN
D
EX
M
AR
K D
AT
E
VOLUME 2
SHEET INDEX
SHEET
NUMBER SHEET TITLE
T-102 SYSTEMS PLAN - B
T-103 SYSTEMS PLAN - C
T-104 SYSTEMS PLAN - D
T-105 SYSTEMS PLAN - E
T-106 SYSTEMS PLAN - FIRE PUMP BUILDING
T-401 SYSTEMS PLANS
T-402 SYSTEMS PLANS
T-501 SYSTEMS DETAILS
T-502 SYSTEMS DETAILS
T-503 SYSTEMS DETAILS
T-504 SYSTEMS DETAILS
T-601 SYSTEMS RISERS
VOLUME 2
SHEET INDEX
SHEET
NUMBER SHEET TITLE
P-119 PLUMBING - NATURAL GAS PLAN PART 'C'
P-120 PLUMBING - NATURAL GAS PLAN PART 'D'
P-121 PLUMBING - NATURAL GAS PLAN PART 'F'
P-122 PLUMBING - ROOF PLAN PART 'A'
P-123 PLUMBING - ROOF PLAN PART 'B'
P-124 PLUMBING - ROOF PLAN PART 'C'
P-125 PLUMBING - ROOF PLAN PART 'D'
P-126 PLUMBING - ROOF PLAN PART 'F'
P-171 PLUMBING - PUMP HOUSE
P-301 PLUMBING BUILDING SECTIONS
P-302 PLUMBING BUILDING SECTIONS
P-401 PLUMBING ENLARGED PLANS - ADMIN DOMESTIC WATER
P-402 PLUMBING ENGLARGED PLANS - ADMIN SANITARY SEWER &
VENT
P-501 PLUMBING - DETAILS
P-502 PLUMBING - DETAILS
P-503 PLUMBING - DETAILS
P-504 PLUMBING - DETAILS
P-901 PLUMBING - DOMESTIC WATER 3D VIEW
P-902 PLUMBING - SANITARY SEWER & VENT 3D VIEW
P-903 PLUMBING - COMPRESSED AIR 3D VIEW
P-904 PLUMBING - NATURAL GAS 3D VIEW
MECHANICAL
M-001 MECHANICAL - HVAC LEGEND
M-101 MECHANICAL - HVAC COMPOSITE FLOOR PLAN
M-102 MECHANICAL - HVAC FLOOR PLAN PART 'A'
M-103 MECHANICAL - HVAC FLOOR PLAN PART 'B'
M-104 MECHANICAL - HVAC FLOOR PLAN PART 'C'
M-105 MECHANICAL - HVAC FLOOR PLAN PART 'D'
M-106 MECHANICAL - HVAC FLOOR PLAN PART 'F'
M-171 MECHANICAL - PUMP HOUSE
M-301 MECHANICAL - HVAC BUILDING SECTION
M-501 MECHANICAL - HVAC DETAILS
M-502 MECHANICAL - HVAC DETAILS
M-503 MECHANICAL - HVAC DETAILS
M-601 MECHANICAL - HVAC SCHEDULES
M-602 MECHANICAL - HVAC SCHEDULES
M-700 MECHANICAL - HVAC CONTROLS LEGEND
M-701 MECHANICAL - HVAC CONTROLS AHU-1,2
M-702 MECHANICAL - HVAC CONTROLS EXHAUST FANS & HEATERS
M-901 MECHANICAL - HVAC 3D VIEW
MS101 MECHANICAL SPECIALTIES FLOOR PLAN & SCHEDULE
ELECTRICAL
E-001 ELECTRICAL LEGEND AND ABBREVIATIONS
ED001 ELECTRICAL DEMOLITION SITE PLAN
ED002 ELECTRICAL DEMOLITION SITE PLAN
ES001 ELECTRICAL SITE PLAN
ES002 ELECTRICAL SITE PLAN
ES501 ELECTRICAL SITE DETAILS
ES502 ELECTRICAL SITE DETAILS
ES503 ELECTRICAL SITE DETAILS
E-101 HAZARDOUS AREA CLASSIFICATION PLAN
E-102 HAZARDOUS AREA CLASSIFICATION PLAN
E-103 HAZARDOUS AREA CLASSIFICATION PLAN
EL101 LIGHTING PLAN - A
EL102 LIGHTING PLAN - B
EL103 LIGHTING PLAN - C
EL104 LIGHTING PLAN - D
EL105 LIGHTING PLAN - E
EL106 LIGHTING PLAN - FIRE PUMP BUILDING
EL501 LIGHTING SCHEDULES & DETAILS
EL502 LIGHTING DETAILS
EL503 LIGHTING DETAILS
EL504 LIGHTING CONTROL DETAILS
EP101 POWER PLAN - A
EP102 POWER PLAN - B
EP103 POWER PLAN - C
EP104 POWER PLAN - D
EP105 POWER PLAN - E
EP106 POWER PLAN - FIRE PUMP BUILDING
EP501 POWER DETAILS
EP601 POWER RISER
EP602 POWER RISERS
EP603 ELECTRICAL SINGLE LINE DIAGRAM
EP604 ELECTRICAL SCHEDULES
EP605 PANEL SCHEDULES
EP606 PANEL SCHEDULES
EP607 PANEL SCHEDULES
EP608 PANEL SCHEDULES
EP609 PANEL SCHEDULES
EP610 PANEL SCHEDULES
EG101 LIGHTNING PROTECTION & GROUNDING PLAN - A
EG102 LIGHTNING PROTECTION & GROUNDING PLAN - B
EG103 LIGHTNING PROTECTION & GROUNDING PLAN - C
EG104 LIGHTNING PROTECTION & GROUNDING PLAN - FIRE PUMP
BUILDING
EG105 LIGHTNING PROTECTION ROOF PLAN - A
EG106 LIGHTNING PROTECTION ROOF PLAN - B
EG107 LIGHTNING PROTECTION ROOF PLAN - C
EG108 LIGHTNING PROTECTION ROOF PLAN - FIRE PUMP BUILDING
EG501 LIGHTNING PROTECTION & GROUNDING DETAILS
EG502 LIGHTNING PROTECTION & GROUNDING DETAILS
EC501 CATHODIC PROTECTION DETAILS
EC502 CATHODIC PROTECTION DETAILS
EC503 CATHODIC PROTECTION DETAILS
EC504 CATHODIC PROTECTION WATER TANK DETAILS
EC505 CATHODIC PROTECTION WATER TANK DETAILS
ELECTRONIC SYSTEMS
T-001 SYSTEMS LEGEND
TD001 TELECOMMUNICATIONS DEMOLITION SITE PLAN
TD002 TELECOMMUNICATIONS DEMOLITION SITE PLAN
TS001 TELECOMMUNICATIONS SITE PLAN
TS002 TELECOMMUNICATIONS SITE PLAN
TS003 TELECOMMUNICATIONS SITE PLAN
TS501 TELECOMMUNICATIONS SITE DETAILS
TS601 TELECOMMUNICATIONS RISER - OSP
T-101 SYSTEMS PLAN - A
VOLUME 2
SHEET INDEX
SHEET
NUMBER SHEET TITLE
ARCHITECTURE
A-001 GENERAL NOTES, ABBREVIATIONS
A-002 BUILDING CODE AND LIFE SAFETY ANALYSIS
A-005 AIR BARRIER PLAN AND SECTIONS
A-007 AIR BARRIER CONSTRUCTION METHODS
A-100 COMPOSITE FLOOR PLAN
A-101 FLOOR PLAN - AREA "A" -ANNOTATIVE
A-102 FLOOR PLAN - AREA "B" - ANNOTATIVE
A-103 FLOOR PLAN - AREA "C" - ANNOTATIVE
A-104 FLOOR PLAN - AREA "D" - ANNOTATIVE
A-105 FLOOR PLAN - AREA "F" - ANNOTATIVE
A-107 FLOOR PLAN - AREA "A"-DIMENSIONAL
A-108 FLOOR PLAN - AREA "B"-DIMENSIONAL
A-109 FLOOR PLAN - AREA "C"-DIMENSIONAL
A-110 FLOOR PLAN - AREA "D"-DIMENSIONAL
A-111 FLOOR PLAN - AREA "F"-DIMENSIONAL
A-113 COMPOSITE REFLECTED CEILING PLAN
A-114 REFLECTED CEILING PLAN AREA "A"
A-115 REFLECTED CEILING PLAN AREA "B"
A-116 REFLECTED CEILING PLAN AREA "C"
A-117 REFLECTED CEILING PLAN AREA "D"
A-118 REFLECTED CEILING PLAN AREA "F"
A-120 COMPOSITE ROOF PLAN
A-121 ROOF PLAN AREA "A"
A-122 ROOF PLAN AREA "B"
A-123 ROOF PLAN AREA "C"
A-124 ROOF PLAN AREA "D"
A-125 ROOF PLAN AREA "F"
A-150 FIRE PUMP FACILITY - PLANS
A-201 EXTERIOR ELEVATIONS
A-250 FIRE PUMP FACILITY - ELEVATIONS
A-301 BUILDING S SECTIONS
A-302 BUILDING SECTIONS
A-305 FIRE PUMP FACILITY - SECTIONS
A-310 WALL SECTIONS
A-311 WALL SECTIONS
A-401 RESTROOM EQUIPMENT MOUNTING HEIGHTS
A-402 ENLARGED PLANS - RESTROOMS
A-403 INTERIOR ELEVATIONS & SECTIONS
A-501 ENLARGED PLAN DETAILS
A-505 WALL DETAILS
A-510 ROOF DETAILS
A-511 ROOF DETAILS
A-513 DETAILS - MISCELLANEOUS
A-514 FIRE EXTINGUSHER CABINET DETAILS
A-515 FIRE EXTINGUISHER CABINET DETAILS
A-601 PARTITION TYPES
A-602 ROOM FINISH SCHEDULE & DETAILS
A-603 DOOR SCHEDULE
A-604 DOOR DETAILS - INTERIOR
A-605 DOOR DETAILS - EXTERIOR
A-606 WINDOW TYPES / DETAILS
A-607 MECHANICAL LOUVER / FLUE DETAILS
INTERIOR
I-101 FURNITURE PLAN – AREA “F”
FIRE PROTECTION
FL100 LIFE SAFETY ANALYSIS
FL101 LIFE SAFETY OVERALL PLAN
FL102 LIFE SAFETY PLAN - AREA A
FL103 LIFE SAFETY PLAN - AREA B
FL104 LIFE SAFETY PLAN - AREA C
FL105 LIFE SAFETY PLAN - AREA D
FL106 LIFE SAFETY PLAN - AREA F
FX001 FIRE SUPPRESSION LEGEND & GENERAL NOTES
FX101 FIRE SUPPRESSION COMPOSITE PLAN
FX301 FIRE SUPPRESSION SECTIONS
FX401 FIRE SUPPRESSION – ENLARGED PLAN
FX402 FIRE SUPPRESSION – ENLARGED PLAN
FX501 FIRE SUPPRESSION DETAILS
FX502 FIRE SUPPRESSION DETAILS
FX701 FIRE PUMP LAYOUT
FX901 FIRE SUPPRESSION – 3D VIEW SPRINKLER & FOAM RISERS
FA001 FIRE ALARM & MASS NOTIFICATION LEGEND
FA101 FIRE ALARM & MASS NOTIFICATION PLAN - A
FA102 FIRE ALARM & MASS NOTIFICATION PLAN - B
FA103 FIRE ALARM & MASS NOTIFICATION PLAN - C
FA104 FIRE ALARM & MASS NOTIFICATION PLAN - D
FA105 FIRE ALARM & MASS NOTIFICATION PLAN - E
FA106 FIRE ALARM & MASS NOTIFICATION PLAN - FIRE PUMP
BUILDING
FA401 FIRE ALARM & MASS NOTIFICATION PLAN
FA402 FIRE ALARM & MASS NOTIFICATION PLAN
FA501 FIRE ALARM & MASS NOTIFICATION DETAILS
FA502 FIRE ALARM & MASS NOTIFICATION DETAILS
FA503 FIRE ALARM & MASS NOTIFICATION DETAILS
FA601 FIRE ALARM & MASS NOTIFICATION RISER
PLUMBING
P-001 PLUMBING - LEGENDS
P-002 PLUMBING - SCHEDULES
P-101 PLUMBING - COMPOSITE FLOOR PLAN
P-102 PLUMBING - DOMESTIC WATER PLAN PART 'A'
P-103 PLUMBING - DOMESTIC WATER PLAN PART 'B'
P-104 PLUMBING - DOMESTIC WATER PLAN PART 'C'
P-105 PLUMBING - DOMESTIC WATER PLAN PART 'D'
P-106 PLUMBING - DOMESTIC WATER PLAN PART 'F'
P-107 PLUMBING - SANITARY SEWER & VENT PLAN PART 'A'
P-108 PLUMBING - SANITARY SEWER & VENT PLAN PART 'B'
P-109 PLUMBING - SANITARY SEWER & VENT PLAN PART 'C'
P-110 PLUMBING - SANITARY SEWER & VENT PLAN PART 'D'
P-111 PLUMBING - SANITARY SEWER & VENT PLAN PART 'F'
P-112 PLUMBING - COMPRESSED AIR PLAN PART 'A'
P-113 PLUMBING - COMPRESSED AIR PLAN PART 'B'
P-114 PLUMBING - COMPRESSED AIR PLAN PART 'C'
P-115 PLUMBING - COMPRESSED AIR PLAN PART 'D'
P-116 PLUMBING - COMPRESSED AIR PLAN PART 'F'
P-117 PLUMBING - NATURAL GAS PLAN PART 'A'
P-118 PLUMBING - NATURAL GAS PLAN PART 'B'
VOLUME 1
SHEET INDEX
SHEET
NUMBER SHEET TITLE
CG312 AIRCRAFT PARKING APRON CROSS SECTIONS
CG313 ACCESS APRON & HANGAR CROSS SECTIONS
CG314 ACCESS APRON & HANGAR CROSS SECTIONS
CG315 ACCESS APRON & HANGAR CROSS SECTIONS
CG316 ACCESS APRON & HANGAR CROSS SECTIONS
CG317 ACCESS APRON & HANGAR CROSS SECTIONS
CG318 ACCESS APRON & HANGAR CROSS SECTIONS
CG401 STORM WATER MANAGEMENT POND LAYOUT AND GRADING
PLAN
CG402 POND SECTION CUTS
CG403 POND SUBDRAIN DETAILS
CG404 HANGAR ENLARGED GRADING PLAN
CG405 HANGAR ROOF DRAIN PLAN
CG406 HANGAR ROOF DRAIN PLAN
CG407 HANGAR ROOF DRAIN PLAN
CG501 MISCELLANEOUS DRAINAGE DETAILS
CG502 MISCELLANEOUS DRAINAGE DETAILS
CG503 MISCELLANEOUS DRAINAGE DETAILS
CG504 TRENCH DRAIN DETAILS
CG505 RIP RAP DETAILS
CG506 CONFLICT MANHOLE STRUCTURE DETAILS
CG601 DRAINAGE STRUCTURE TABLES
CG602 DRAINAGE STRUCTURE TABLES
CG603 DRAINAGE STRUCTURE TABLES
CU101 UTILITY PLAN
CU102 UTILITY PLAN
CU103 UTILITY PLAN
CU104 UTILITY PLAN
CU105 UTILITY PLAN
CU200 UTILITY PROFILES
CU201 SANITARY SEWER STRUCTURE AND PIPE TABLES
CU501 WATER UTILITY DETAILS
CU502 WATER UTILITY DETAILS
CU503 WATER UTILITY DETAILS
CU504 WATER TANK DETAILS
CU505 WATER TANK DETAILS
CU506 WATER AND SEWER UTILITY DETAILS
CU507 SANITARY SEWER DETAILS
CU508 LIFT STATION DETAILS
CU509 LIFT STATION DETAILS
CU510 LIFT STATION DETAILS
CU511 CONTAINMENT TANK AND DIVERTER VALVE DETAILS
CU512 OIL WATER SEPARATOR DETAILS
CU513 OIL WATER SEPARATOR DETAILS
CU600 BID OPTION GAS LINE
CU601 BID OPTION GAS LINE
CU602 BID OPTION GAS LINE
CU603 BID OPTION GAS LINE
STRUCTURAL
S-001 GENERAL STRUCTURAL NOTES, DESIGN LOADS &
ABBREVIATIONS
S-002 COMPONENT AND CLADDING WIND LOADS
S-100 PROJECT REFERENCE PLAN
S-101 FOUNDATION PLAN - AREA A
S-102 FOUNDATION PLAN - AREA B
S-103 FOUNDATION PLAN - AREA C
S-104 FOUNDATION PLAN - AREA D
S-105 FOUNDATION PLAN - AREA F
S-106 SLAB PLAN - AREA A
S-107 SLAB PLAN - AREA B
S-108 SLAB PLAN - AREA C
S-109 SLAB PLAN - AREA D
S-110 SLAB PLAN - AREA F
S-113 ADMINISTRATION ROOF FRAMING PLAN
S-114 FIRE EQUIPMENT ROOM ROOF FRAMING PLANS
S-115 TOP OF DOOR FRAMING PLANS
S-116 BOTTOM CHORD FRAMING PLAN - AREA A
S-117 BOTTOM CHORD FRAMING PLAN - AREA B
S-118 BOTTOM CHORD FRAMING PLAN - AREA C
S-119 BOTTOM CHORD FRAMING PLAN - AREA D
S-121 TOP CHORD FRAMING PLAN - AREA A
S-122 TOP CHORD FRAMING PLAN - AREA B
S-123 TOP CHORD FRAMING PLAN - AREA C
S-124 TOP CHORD FRAMING PLAN - AREA D
S-171 FIRE PUMP ROOM FOUNDATION PLAN
S-172 FIRE PUMP ROOM ROOF PLAN
S-173 FIRE PUMP ROOM SECTIONS
S-174 FIRE PUMP TANK FOUNDATION PLANS
S-201 FRAMING ELEVATIONS
S-202 FRAMING ELEVATIONS
S-204 FRAMING ELEVATIONS
S-205 FRAMING ELEVATIONS
S-206 FRAMING ELEVATIONS
S-207 TRUSS ELEVATIONS
S-208 FRAMING ELEVATIONS
S-209 GIRT FRAMING ELEVATIONS
S-210 GIRT FRAMING ELEVATIONS
S-211 GIRT FRAMING ELEVATIONS
S-212 GIRT FRAMNG ELEVATIONS
S-213 GIRT FRAMING ELEVATIONS
S-214 GIRT FRAMING ELEVATIONS
S-301 FOUNDATION SECTIONS
S-302 FOUNDATION SECTIONS
S-303 FOUNDATION SECTIONS
S-304 FRAMING SECTIONS
S-305 ADMINISTRATION ROOF FRAMING SECTIONS
S-306 GIRT FRAMING SECTIONS
S-307 TRUSS RT1 FRAMING SECTIONS
S-308 TRUSS FRAMING SECTIONS
S-309 TRUSS FRAMING SECTIONS
S-310 HANGAR ROOF ACCESS LADDER SECTIONS AND DETAILS
S-501 TYPICAL CONCRETE DETAILS
S-502 TYPICAL CONCRETE DETAILS
S-503 TYPICAL MASONRY WALL DETAILS
S-504 TYPICAL STRUCTURAL BASE PLATE DETAILS
S-505 TYPICAL FRAMING DETAILS
S-603 FOOTING SCHEDULES
VOLUME 1
SHEET INDEX
SHEET
NUMBER SHEET TITLE
GENERAL
G-001 COVER SHEET
G-002 SHEET INDEX
CIVIL
GC001 LOCATION/VICINITY MAP
GC002 PROJECT ABBREVIATIONS SHEET
GC003 LEGEND
GC004 GENERAL NOTES
GC005 OVERALL SITE MAP
GC006 BID INFORMATION SHEET
GC101 PHASE 1 AND AIR TRAFFIC CONTROL PLAN & CONTROL
ACCESS PLAN
GC102 PHASE 2 AND AIR TRAFFIC CONTROL PLAN & CONTROL
ACCESS PLAN
GC501 PHASING DETAILS
V-101 EXISTING CONDITIONS
V-102 EXISTING CONDITIONS
V-103 EXISTING CONDITIONS
V-104 EXISTING CONDITIONS
V-105 EXISTING CONDITIONS
V-106 EXISTING CONDITIONS
V-107 EXISTING CONDITIONS
V-108 EXISTING CONDITIONS
V-109 SURVEY MONUMENTATION
CD101 DEMOLITION PLAN
CD102 DEMOLITION PLAN
CD103 DEMOLITION PLAN
CD104 DEMOLITION PLAN
CD105 DEMOLITION PLAN
CD106 DEMOLITION PLAN
CD107 DEMOLITION PLAN
CD108 DEMOLITION PLAN
CD501 EXISTING EDGE DRAIN DETAILS
CT101 GEOMETRIC LAYOUT PLAN
CT102 GEOMETRIC LAYOUT PLAN
CT103 GEOMETRIC LAYOUT PLAN
CT104 GEOMETRIC LAYOUT PLAN
CT105 GEOMETRIC LAYOUT PLAN
CT106 GEOMETRIC LAYOUT PLAN
CT107 GEOMETRIC LAYOUT PLAN
CT108 GEOMETRIC LAYOUT PLAN
CT401 AIRCRAFT PARKING APRON CONCRETE JOINT & ELEVATION
PLAN
CT402 AIRCRAFT PARKING APRON CONCRETE JOINT & ELEVATION
PLAN
CT403 AIRCRAFT PARKING APRON CONCRETE JOINT & ELEVATION
PLAN
CT404 HANGAR APRON CONCRETE JOINT ELEVATION PLAN
CT405 HANGAR APRON CONCRETE JOINT ELEVATION PLAN
CT501 FE-6 SECURITY FENCE DETAILS
CT502 SLIDING GATE DETAIL
CT503 FE-6 DOUBLE SWING GATE
CT504 FARM FENCE DETAILS
CT505 DUMPSTER PAD DETAILS
CT601 ROADWAY CURVE DATA SCHEDULES
CP101 PAVING AND MARKING PLAN
CP102 PAVING AND MARKING PLAN
CP103 PAVING AND MARKING PLAN
CP104 PAVING AND MARKING PLAN
CP105 PAVING AND MARKING PLAN
CP301 HANGAR AND ACCESS APRON SECTION CUTS
CP302 HMA ACCESS ROAD DETAILS
CP303 PARKING APRON SECTION CUTS AND TYPICAL SECTIONS
CP304 PARKING APRON SECTION CUT
CP305 HMA ACCESS ROAD DETAILS
CP401 ENLARGEMENT MARKING PLAN AND PAVING LAYOUT PLAN
CP501 PAVEMENT SECTIONS
CP502 DRAINAGE LAYER AND PAVEMENT SECTIONS
CP503 DRAINAGE LAYER AND PAVEMENT SECTIONS
CP504 CONCRETE JOINT STANDARD DETAILS
CP505 AIRFIELD PAVEMENT DETAILS
CP506 MOORING DEVICE AND STATIC GROUND LAYOUT
CP507 MOORING DEVICE AND STATIC GROUND DETAILS
CP508 ROADWAY MARKING DETAILS
CP509 AIRFIELD MARKING DETAILS
CP510 HANGAR ACCESS APRON DETAILS
CP511 JOINT DETAILS
CG101 GRADING PLAN
CG102 GRADING PLAN
CG103 GRADING PLAN
CG104 GRADING PLAN
CG105 GRADING PLAN
CG106 GRADING PLAN
CG107 GRADING PLAN
CG108 GRADING PLAN
CG201 ACCESS ROAD PROFILE
CG202 HANGAR SERVICE ROAD PROFILE
CG203 TAXILANE CENTERLINE PROFILE
CG204 STORM DRAINAGE PROFILES
CG205 STORM DRAINAGE PROFILES
CG206 STORM DRAINAGE PROFILES
CG207 STORM DRAINAGE PROFILES
CG208 STORM DRAINAGE PROFILES
CG209 STORM DRAINAGE PROFILES
CG210 STORM DRAINAGE PROFILES
CG211 STORM DRAINAGE PROFILES
CG212 DITCH PROFILE
CG301 AIRCRAFT PARKING APRON CROSS SECTIONS
CG302 AIRCRAFT PARKING APRON CROSS SECTIONS
CG303 AIRCRAFT PARKING APRON CROSS SECTIONS
CG304 AIRCRAFT PARKING APRON CROSS SECTIONS
CG305 AIRCRAFT PARKING APRON CROSS SECTIONS
CG306 AIRCRAFT PARKING APRON CROSS SECTIONS
CG307 AIRCRAFT PARKING APRON CROSS SECTIONS
CG308 AIRCRAFT PARKING APRON CROSS SECTIONS
CG309 AIRCRAFT PARKING APRON CROSS SECTIONS
CG310 AIRCRAFT PARKING APRON CROSS SECTIONS
CG311 AIRCRAFT PARKING APRON CROSS SECTIONS
DRAWING ABBREVIATIONS
NUMBERING SYSTEM:
XX100
DISCIPLINE:
C - CIVIL
L - LANDSCAPE
A - ARCHITECTURE
M - MECHANICAL
E - ELECTRICAL
P - PLUMBING
S - STRUCTURAL
K - FOOD SERVICEDISCIPLINE MODIFIER
SHEET NUMBER WITHIN
SERIES
ANNOTATION CALLOUTS/DRAWING SYMBOLS
GENERAL NOTES
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE MANUFACTURER'S
ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED/CONTRACTOR
INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HTCEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORDCOORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND FINISH
SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE BOARD
(INSULATION)
ETS EXPOSED TO STRUCTURE
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GREXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BDFASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDTN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FT FEET
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED FURNISHED
INSTALLED BY GOVERNMENT
GFRG GLASS-FIBER-REINFORCED GYPSUM
GPC GROUND AND POLISHED CONCRETE
FINISH
GLZ GLAZING
GSF GROSS SQUARE FEET
GSM GROSS SQUARE METERS
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE AIR
(FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MM MILIMETERS
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PFM PLATFORM
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
REFER TO AEC CAD
STANDARDS FOR PROPER
SHEET NUMBERING
REVISION
TAG
NORTH ARROW w/
TRUE NORTH
INDICATION
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
A SHEET KEYNOTE
INTERIOR ELEVATION
SHEET NUMBER
PLAN NORTH
A-101
Ref
A-101
SIM
CONCRETE/ PRECAST
CONCRETE
SOIL
SAND, EIFS FINISH
COAT, OR CEMENT
PLASTER
CMU
FIBERGLASS BATT
INSULATION
EXTRUDED
POLYSTYRENE RIGID
INSULATION
POLYISOCYANURATE
RIGID INSULATION
GYPSUM BOARD
PLYWOOD
MATERIALS
INTERIOR ELEVATIONA101
Ref
A101
Ref
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL
(FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
1. FACILITY DESCRIPTION: NEW 63,873 GSF AIRCRAFT AND FLIGHT EQUIPMENT
BUILDING, WITH SUPPORTING FACILITIES CONSISTING OF A FIRE PUMP BUILDING. THE
PROPOSED AIRCRAFT AND FLIGHT EQUIPMENT FACILITY IS COMPOSED OF THE
AIRCRAFT SERVICING AREA, TECHNICIAN SHOPS, COMPANY ADMINISTRATIVE AND
OPERATIONS FUNCTIONAL AREAS. THE AIRCRAFT SERVICING AREA IS AN OPEN HIGH-
BAY WITH 8 UH-60 MAINTENANCE MODULES. AIRCRAFT BAY CLEARANCES ARE BASED
ON ARMY STANDARDS. THE BUILDING ORIENTATION AND FUNCTIONAL
RELATIONSHIPS WERE ESTABLISHED BASED ON SITE CONSTRAINTS, EXISTING
FUNCTIONAL FACILITIES, AND USER INTERVIEWS.
2. CODE CONSIDERATIONS: BUILDING IS PER IBC, TYPE II-B CONSTRUCTION
COMPLIANT WITH UFC 3-600-01, NFPA 409, AND AS ALLOWED BY UFC 4-211 01.
PORTIONS OF THE FACILITY OTHER THAN AIRCRAFT SERVICING AREAS ARE TO BE
SEPARATED BY ONE-HOUR FIRE-RATED WALLS.
A) OCCUPANCY CLASSIFICATION: PER IBC: F-1 PRIMARY OCCUPANCY;
ACCESSORY OCCUPANCY BUSINESS (B) OCCUPANCY. PER NFPA 101: FOR
EGRESS AND OCCUPANT LOAD, BUILDING IS CONSIDERED A MIXED
OCCUPANCY SEPARATED: BUSINESS AND INDUSTRIAL.
B) CONSTRUCTION TYPE: PER IBC: CONSTRUCTION TYPE II-B, UFC4-211-01
PARA 3-3.1.1
C) SEPARATION REQUIREMENTS: UFC 4-211-01 PARAGRAPH 3-3.1.3 GOVERNS
SEPARATION OF ONE HOUR FIRE BARRIER BETWEEN AIRCRAFT BAYS AND
SUPPORT AREA. AND ONE HOUR SEPARATION FOR FIRE PROTECTION
EQUIPMENT ROOMS.
D) SPACING OF STRUCTURES: THIS FACILITY WILL BE SEPARATED BY A MINIMUM
OF 60 FEET ALL SIDES FROM OTHER BUILDINGS.
3. BUILDING CONSTRUCTION / SCOPE REQUIREMENTS:
A)NEW HANGAR: HANGAR BAYS ARE TO BE ENCLOSED BY CMU WALLS WITH STEEL
GIRTS AND WALL PANELS ABOVE; HANGAR BAY ROOF IS LOW SLOPE MODIFIED
BITUMEN ROOF SYSTEM OVER INSULATION AND STRUCTURAL DECK. THE
ADMINISTRATION AREA SHALL HAVE A STANDING SEAM METAL ROOF OVER
INSULATION AND STRUCTURAL DECK. FLIGHT LINE ACCESS IS PROVIDED BY
CONTINUOUS MOTOR OPERATED SLIDING HANGAR DOORS. THREE 10 TON BRIDGE
CRANES WILL SERVICE THE HANGAR BAYS. PORTIONS OF THE FACILITY OTHER THAN
AIRCRAFT SERVICING AREAS ARE TO BE SEPARATED BY ONE-HOUR FIRE-RATED UNIT
MASONRY WALLS. IN OFFICE AREAS INTERIOR PARTITIONS SHALL BE GYPSUM BOARD
ON METAL STUDS. INTERIOR CEILINGS SHALL BE LAY-IN ACOUSTICAL TYPE IN OFFICE
AREAS WITH GYPSUM BOARD IN TOILET AREAS. TECHNICIAN SUPPORT AREAS SHALL
HAVE UNIT MASONRY WALLS WITH GYPSUM BOARD FURRED GYPSUM BOARD WALLS
AND A LAY-IN ACOUSTICAL TILE CEILING. STEEL JOIST WITH STEEL ROOF DECK SHALL
SUPPORT THE ARCHITECTURAL METAL ROOF SYSTEM. FINISH MATERIALS FOR
WALLS, FLOORS, AND CEILINGS WILL FOLLOW THE INSTALLATION DESIGN GUIDES
AND RESPECTIVE UFC'S. SUSTAINABLE DESIGN, ASHRAE 189.1 & 90.1 FEATURES
INCLUDE EXTERIOR WALLS CONTINUOUSLY INSULATED TO R13 AND THE ROOF
SYSTEM CONTINUOUSLY INSULATED TO R25. INDOOR ENVIRONMENTAL QUALITY
FEATURES INCLUDE DAY-LIGHTING TO HANGAR BAY AREAS AND DAYLIGHTING TO
OTHER AREAS.
B) FIRE PUMP BUILDING: THIS WORK WILL CONSIST OF A CONSTRUCTED 1966 SF
CONCRETE BLOCK BUILDING (TO MATCH EQUIPMENT FACILITY) WITH A METAL ROOF .
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-001
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
G
EN
ER
AL
N O
TE
S, A
BB
R
EV
IA
TI
O N
S
M
AR
K D
AT
E
BUILDING CODE AND LIFE SAFETY ANALYSIS
PROJECT INFORMATION
BUILDING OCCUPANCY TYPE (MIXED OCCUPANCY)
CONSTRUCTION TYPE (BUILDING IS FULLY
PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM)
FLOOR AREAS BY OCCUPANCY
MODERATE-HAZARD STORAGE (S-1) (INCLUDES FOAM RISER ROOMS AND HANGAR)
BUSINESS (B) (OFFICE AND WORK ROOMS)
TOTAL OCCUPANT LOAD (SEE LIFE SAFETY FOR BREAK
DOWN)
OCCUPANCY CLASSIFICATIONS - (DESIGN CRITERIA)
OCCUPANCY CLASSIFICATIONS (EGRESS PURPOSES)
MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT - GEN. INDUSTRIAL
MAX. FLOOR AREA ALLOWANCE PER OCCUPANT - HANGAR BAY
MAXIMUM FLOOR AREA ALLOWANCE PER OCCUPANT - BUSINESS AREAS
MIXED USE SEPARATION - (IBC)
HAZARD OF CONTENTS CLASSIFICATION
GENERAL BUILDING LIMITATIONS
BASIC ALLOWABLE AREA
BASIC ALLOWABLE STORIES
BASIC ALLOWABLE HEIGHT
INCREASE - SEPARATION - 4 SIDES
AREA MODIFICATIONS INCREASE FRONTAGE
SPRINKLER INCREASE
ALLOWABLE FLOOR AREA INCREASE (PER STORY)
EXTERIOR FIRE RESISTANCE RATING REQUIREMENTS
BEARING WALLS
NON-BEARING WALLS
WALLS AND OPENINGS
INTERIOR FIRE RESISTANCE RATING REQUIREMENTS
BEARING WALLS
NON-BEARING WALLS AND PARTITIONS
STRUCTURAL FRAME
ROOF CONSTRUCTION - INCLUDING SUPPORTING BEAMS AND JOISTS
GLAZING @ 0.75 HR DOOR (WIRED)
INTERIOR FINISHES / REQUIREMENTS
NATURAL LIGHT OPENING
EGRESS LIGHTING
SOUND TRANSMISSION (MIN.)
6 / 03/ 19
DATE:
IBC - 2015 NFPA 101 - 2015
TYPE II B N/A
63,873 GSF
58,575 GSF
5,298 GSF
N/A
B AND S-1; NO REQ.
SEPARATION
IBC-TABLE 508.4
N/A
SEC. 507.4 S-1 = UNLIMITED SF;
B = UNLIMITED SF
S-1 = 3; B=4
N/A
N/AIBC-SECTION 507
IBC-SECTION 506
IBC-SECTION 507
IBC-SECTION 507.4
FIRE RATED DOORS (REF: DOOR SCHEDULE)
MAX. ASSEMBLY AREA PER SQ. INCH
MAX. ASSEMBLY HEIGHT PER INCH
MAX. ASSEMBLY WIDTH PER INCH
EXIT PASSAGEWAYS
FLAME SPREAD INDEX (SPRINKLED) EXIT
ACCESS CORRIDORS AND OTHER EXITWAYS
ROOMS AND ENCLOSED SPACES
FINISH FLOOR EXIT ENCLOSURES
BUILDING CODE AND LIFE SAFETY ANALYSIS
PROJECT INFORMATION
6/ 3 / 19
DATE:
IBC - 2015 NFPA 101 - 2015
MEANS OF EGRESS REQUIREMENTS
DOOR WIDTH (MIN.)
DOOR HEIGHT (MIN.)
DOOR WIDTH (MAX.)
DOOR OPENING FORCE (NFPA / ETL 02-15-2002)
TRAVEL DISTANCE - BUSINESS AREA (FT)
COMMON PATH - BUSINESS AREA (FT)
DEAD-END LIMIT - BUSINESS AREA (FT)
MIN. # OF EXITS (PER STORY)(1-500) OCCUPANT LOAD
MIN. EGRESS WIDTH - CORRIDORS (INCHES)
MIN. EGRESS WIDTH - LEVEL COMPONENTS AND RAMPS
EGRESS CALCULATIONS
STAIR WIDTH CALCULATION (INCHES)
EGRESS WIDTH - LEVEL COMPONENTS AND RAMPS
(TOTAL OCC. X IN. PER PERSON);
DESIGN OCCUPANTS LOAD FOR MEANS OF EGRESS
CORRIDOR WIDTH (INCHES) - REQ.
EXIT DOOR WIDTH (INCHES) - MINIMUM REQUIRED
EXIT DOOR WIDTH (INCHES) - MINIMUM PROVIDED
FIRE PROTECTION SYSTEMS
SMOKE DETECTION
FIRE SPRINKLER SYSTEMS
FIRE EXTINGUISHERS
OCCUPANCY HAZARD CLASSIFICATION
MIN. RATED SINGLE EXTINGUISHER (NFPA 10)
MAX. FLOOR AREA PER UNIT OF A (NFPA 10)
MAX. FLOOR AREA FOR EXTINGUISHER (NFPA 10)
MAX. TRAVEL DISTANCE TO EXTINGUISHER (NFPA 10)
PLUMBING FIXTURE CALCULATIONS
WATER CLOSETS - REQUIRED (TOTAL MEN & WOMEN)
WATER CLOSETS - PROVIDED
LAVATORIES - REQUIRED (TOTAL MEN & WOMEN)
LAVATORIES - PROVIDED
DRINKING FOUNTAINS - REQUIRED (TOTAL)
DRINKING FOUNTAINS - PROVIDED
SERVICE SINK - REQUIRED (TOTAL)
SERVICE SINK - PROVIDED
IBC-TABLE 2902.1 B:1 PER 25, AFTER
PER 50 =2
S-1:1 PER 100=2
IBC-TABLE 2902.1
IBC-TABLE 2902.1
IBC-TABLE 2902.1 1 SERVICE SINK
UFC 3-600-01UFC 3-600-01
N/A
GEN. INDUST.; BUSINESS
SPECIAL PURPOSE
(WORK-STATION COUNT USED)
500SF
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
SECTION 38.3.3 WALL/CEILING - A, B OR C
NFPA-SECTION 38.3.3
N/A
SECTION 7.8.1.3 - NOT LESS THAN 1FC
@ FLR
N/A
7.2.1.2.3 - 32" CLEAR
7.1.5.2 - 80"
7.2.1.4.5 - 15 LBS MAX
TRAVEL DISTANCE IN HANGAR BAY (NFPA & UFC 4-211-01) 40.6.1.2=150' (@EXT. WALLS)
HORIZONTAL EXIT - INDUSTRIAL AREA (FT) (I)40.2.6 - 400';B:300'
B:100',I:100' B:50',I:50'
7.4.1.1 = 2
7.3.3.1; 0.40" PER PERSON
(MIN. 44")
7.3.3.1; 0.20" PER PERSON
DRAFT CURTAINS
PER IBC
N/A N/A
PER IBC
N/A
N/A
TABLE 10-1 &
PER NFPA 101
N/A
PER IBC
N/A
PER NFPA
N/A
N/A
N/A
N/A N/A
N/A N/A
N/A
7.3.3.1; 83 X .40" = 33.2"
26 persons 7.3.4; = 44" min.
7.2.1.3.2; 32"
N/A
REQUIRED
N/A
N/A
N/A
N/A N/A
N/A N/A
N/A
75'
11,250 SF
1,000 SF
4-A
SPECIAL-PURPOSE
INDUSTRIAL
N/A
N/A
NFPA 220, TABLE 4.1.1=0
PER NFPA 80
N/A
PER IBC
PER NFPA
(INCHES)
UFC 4-211-01 UFC 4-211-01
PER IBC
SEC. 3-3.1.7
UNLIMITED
N/A
N/A
N/A N/A
PER UFC 3-600-01
PER IBC
N/A N/A N/A
PER IBC & SEC.
3-3.1.3; REQ. 1 HR @
HANGAR / ADMIN.
PER SECTION 3-3.1.9
PER UFC 3-600-01
N/A
N/A N/A
N/A N/A
N/A N/A
N/A N/A
NFPA 101(7.3.1.2)
UFC 3-600-01 TABLE 10-1)
NFPA 101(7.3.1.2)
DRAFT CURTAINS N/A
WATER DENSITY N/A
HIGH EXPANSION FOAM DENSITY
TRENCH DRAINS
N/A N/A
N/A
N/A
36"
TABLE 504.4
TABLE 504.3
N/A
PER NFPA 80
PER NFPA 80
PER NFPA 80
PER NFPA 80
SECTION 38.3.3 WALL/CEILING - A OR B
SECTION 38.3.3 WALL/CEILING - A,B OR C
SECTION 38.3.3 - CLASS II
N/A
N/A N/A
N/A
N/A N/A
N/A
PER IBC N/A
PER IBC
N/A
PER IBC
PER UFC 3-600-01
PER NFPA IN
FIRE WALLS
TABLE 601 = 0
TABLE 602 = 0
RATED SAME AS WALL OR OPENING
( IBC UNLESS NOTED OTHERWISE )
N/A N/A N/A N/A N/A
N/A
TABLE 601 = 0
PER IBC
PER IBC
PER NFPA
PER IBC
(NFPA UNLESS NOTED OTHERWISE)
N/A
N/A
N/A N/A
N/A
N/A
N/A
(NFPA UNLESS
NOTED
OTHERWISE)
N/A N/A N/A N/A
N/A N/A N/A
N/A N/A N/A N/A
N/A
N/A
N/A
N/A N/A
N/A N/A
(NFPA U.N.O )
(NFPA U.N.O )
N/A N/A N/A
N/A N/A N/A N/A N/A
N/A N/A N/A N/A
(IBC U.N.O )
( IBC UNLESS NOTED OTHERWISE )
STORAGE (S-1) ; BUSINESS (B)
TOTAL FACILITY S.F.
UNLIMITED (1-STORY)
100SF
B:300'
PER NFPA 101
SECTION 10-3.1
PER NFPA 101
N/A
N/A
PER IBC
PER IBC
N/A
PER IBC
PER IBC
PER IBC
PER IBC
PER IBC
PER IBC
PER IBC
N/A
N/A
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
3-3.1.10 PER NFPA 409
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
(SEE LIFE SAFETY PLAN FOR AREA LOCATIONS)
PER NFPA
PER NFPA
PER NFPA
N/A
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
CORRIDOR WIDTH (INCHES) - MIN. PROVIDED N/A 54"
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER SEC. 9-17
PER NFPA
N/A
PER NFPA
N/A N/A
PER NFPA
PER NFPA
PER NFPA
PER NFPA
GROUP I (NFPA
409)
PER IBC
BUSINESS (B); STORAGE (S-1)
N/A PER UFC 3-600-01
N/A PER UFC 3-600-01
N/A PER UFC 3-600-01
TABLE 601 = 0
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01TABLE 601 = 0
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 4-010-01
PER UFC 3-600-01
PER UFC 3-101-01N/A
N/A
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER NFPA
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER SEC.3-3.1.10
PER SEC. 6-6
PER SEC. 6-6
PER SEC. 6-11 &
NFPA 409
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
PER UFC 3-600-01
B:1 PER 40, AFTER
PER 80 =2
S-1:1 PER 100=2
B:1 PER 100=1
S-1:1 PER 1,000=1
REQUIRED
US Army Corps of Engineers ®
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
B
M
IT
TE
D
B Y:
SI
ZE
C H
EC
K
ED
B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
B
ER
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-002
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T B
U
IL
D
IN
G M
O B
IL
E
D
IS
TR
IC
T
C O
N
TR
AC
TO
R N
AM
E
ST
R
EE
T
AD
D
R
ES
S C
IT
Y, S
TA
TE
Z
IP
ID
C . G
AN
T
C . G
AN
T
M . C
H
IL
D S
JU
N
E
W
0R
M
2Y N
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
B
AM
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
B
IL
E
AL
BU
IL
DI
NG
C O
DE
A
ND
L
IF
E
SA
FE
TY
A
NA
LY
SI
S
M
AR
K
DA
TE
A
A-302
F
E
6 11 12 17 18
D
C
B
56,727 SF
HANGAR BAY
M
AT
C H
LI
N
E "A
M
AT
C H
LI
N
E "B
M
AT
C H
LI
N
E "C
"MATCHLINE "D"FIRE/
FOAM
FIRE/
FOAM
A-005
A-005
A-4025
A-402
7 8 9 102 3 4 5 13 14 15 16 19 20 21 22
F.3
G
1.2 10.8 12.213.7 21.8
H
A-311
A-210
AF E D C B
A-302
F.3G H AF E D C B
A-302
F.3G
AIR / VAPOR BARRIER NOTES:
1. SEE SHEET A001 FOR SYMBOLS, ABBREVIATIONS, LEGENDS,
AND DRAWING CONVENTIONS.
2. FOR BUILDING AIR BARRIER REQUIREMENTS AND PRESSURE
TESTING REQUIREMENTS SEE SPECIFICATION
SECTIONS 07 05 23, 07 27 10.00 10, & 07 27 19.01
3. SEAL ALL PENETRATIONS OF THE AIR BARRIER AND VERIFY
INTEGRITY PRIOR TO COVRING WITH OTHER MATERIALS.
4. SECTIONS ON THIS SHEET ARE SCHEMATIC. SEE DETAILED
BUILDING SECTIONS AND SPECIFICATIONS FOR SPECIFICS ON
AIR BARRIER LOCATION AND INSTALLATION.
5. THE HANGAR BAY SHALL NOT BE PRESSURE TESTED.
AIR BARRIER LEGEND
AIR / VAPOR BARRIER PROTECTED AREA
(PRESSURE TESTING REQUIRED)
AIR / VAPOR BARRIER PROTECTED AREA
(INSTALLATION INSPECTION ONLY)
AIR / VAPOR BARRIER LOCATION
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-005
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
J.
M
. C H
IL
D
S
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
AI
R
B
AR
R
IE
R P
LA
N
A N
D S
EC
TI
O N
S
1" = 30'-0"A-005
1 AIR BARRIER PLAN
1/16" = 1'-0"A-005
2 AIR BARRIER - SECTION @ ADMIN
1/16" = 1'-0"A-005
3 AIR BARRIER - SECTION @ FIRE
M
AR
K D
METAL STUD,
REF: STRUCTURAL
1/2" SHEATHING
REINFORCING MESH
CONTINUOUS AIR BARRIER
EXTERIOR SHEATHING
LOW EXPANSION FOAM.
CURED FOAM SHAVED OFF
FLUSH TO SURFACE
SELF ADHESIVE
SHEATHING TAPE
CONTINUOUS AIR BARRIER
EXTERIOR GYPSUM BOARD SHEATHING
EXTERIOR SHEATHING TAPE
RIGID INSULATION
TERMINATION BAR WITH SEALANT
AND BACKER ROD
THRU-WALL FLASHING
CONTINUOUS AIR BARRIER
REINFORCING MESH
CONTINUOUS SILL SEALER AT
BOTTOM OF METAL STUD TRACK
CONTINUOUS AIR BARRIER
METAL DECKING
EXTERIOR SHEATHING
STRUCTURE
EXAMPLE OF ONE METHOD OF PROPERLY SEALING
CURTAIN WALL, LOUVER AND DOOR OPENINGS.
CUT AND FOLD UP AIR BARRIER
FLASHING AND APPLY SELF-
ADHESIVE MEMBRANE AT HEAD
UNDER THE FLAP
INSTALL SELF-
ADHESIVE MEMBRANE
OVER FRAMED
OPENING HEAD
METAL THRU WALL
FLASHING
INSTALL SELF-ADHESIVE
MEMBRANE OVER FRAMED
OPENING JAMB
INSTALL SELF-
ADHESIVE MEMBRANE OVER
FRAMED SILL AND AIR
BARRIER
SHEET METAL
END DAM
USE SELF-ADHESIVE
MEMBRANE PATCH TO
SEAL ALL PIN HOLES
PER STRUCTURAL /
ARCHITECTURAL DETAILS
EXAMPLE OF THE INSTALLATION OF THE
AIR BARRIER PRIOR TO THE TREATMENT
OF THE ROUGH OPENING OF A WINDOW.
STEEL LINTEL
TAPE AIR BARRIER
TERMINATIONS
(TYPICAL)
INSTALL AIR BARRIER FLASHING
COMPONENTS IN
SHINGLE LIKE FASHION
TO SHED WATER.
MAINTAIN 6" MINIMUM HORIZONTAL
AND VERTICAL LAPS. SECURE AIR
BARRIER COMPONENTS PER
MANUFACTURER'S
RECOMMENDATIONS
ATFP FRAMING
SEE STRUCTURAL SEQUENCE AIR BARRIER
APPLICATION TO ENSURE
PROPER BOND AND
COVERAGE BETWEEN
MEMBRANE AND FLUID
APPLIED COMPONENTS
CMU REF: STRUCTURAL
MASONRY EXPANSION JOINT
FLUSH TO SURFACE
AIR BARRIER SELF ADHESIVE EXTENDED
3" MIN EACH SIDE OF JOINT
CONTINUOUS AIR BARRIER
CMU,
REF: STRUCTURAL
REINFORCING MESH
CONTINUOUS AIR BARRIER
CMU REF: STRUCTURAL
SELF-ADHESIVE MEMBRANE
RIGID INSULATION
TERMINATION BAR WITH SEALANT
AND BACKER ROD
THRU-WALL FLASHING
CONTINUOUS AIR BARRIER
REINFORCING MESH
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-007
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
M . C
H
IL
D S
JU
N
E
W
0R
M
2Y N
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
AI
R
B
AR
R
IE
R C
O N
ST
R
U C
TI
O
N M
ET
H
O D
S
1. DETAILS THIS SHEET SHOW GENERAL METHODS OF INSTALLING
AN INTEGRAL AIR BARRIER SYSTEM AND DO NOT LIMIT THE
SELECTION OF MANUFACTURERS AND MATERIALS THAT ARE
OTHERWISE COMPLIANT WITH CONTRACT REQUIREMENTS.
2. DETAILS SHALL BE ADJUSTED AS NECESSARY TO CONFORM TO
AIR BARRIER SYSTEM MANUFACTURER'S STANDARD DETAILS.
GENERAL NOTES:
12" = 1'-0"A-007
F1 TYPICAL AIR BARRIER AT CORNER
12" = 1'-0"A-007
D1 JOINT DETAIL
12" = 1'-0"A-007 A1
A.B. CONSTRUCTION DETAIL @ ROOF
TRANSITION
12" = 1'-0"A-007
A7 WINDOWS AND DOORS
12" = 1'-0"A-007
A4 WINDOWS AND DOORS
12" = 1'-0"A-007
D4 JOINT DETAIL
12" = 1'-0"A-007
F4 TYPICAL AIR BARRIER AT CORNER
12" = 1'-0"A-007
D7 A.B. CONSTRUCTION DETAIL @ WALL BASE
M
AR
K D
A-302
1'
0"
0"
5'
0"
F
E
6 11 12 17 18
0"
0"
O/F WALL
A-301
D
C
B
A-301
56,727 SF
HANGAR BAY
0"
0"
1'
/4
1'
1/ 4"
549' - 6 1/2" O/F WALL
112' - 7 1/4" 220' - 5 3/4"216' - 5 1/2"
M
AT
C H
LI
N
E "A
M
AT
C H
LI
N
E "B
M
AT
C H
LI
N
E "C
MATCHLINE "D"
O/F WALL O/F WALL O/F WALL
MECH.
OFFICE
OFFICE
CONF.
CONF.
BREAK
RECEP.COMMELEC
WORK
RM.
FIRE/FOAM FIRE/FOAM
A-201
A-201
A-201 3A-201
7 8 9 102 3 4 5 13 14 15 16 19 20 21 22
64' - 0"
5' - 0"
5'
0"
FIRE
F.3
G 1.2 10.8 12.213.7 21.8
H
O /F
W
AL
L
A-311
A-210
KEY PLAN
PLAN NORTH
A B C D
F
NOTES:
1. SEE STRUCTURAL DRAWINGS FOR EXACT GRID DIMENSIONING
2. COMPOSITE PLAN PROVIDES THE OVERALL RELATIONSHIP OF THE BUILDING
ELEMENTS. REFER TO ENLARGED VIEWS FOR MORE EXACT INFORMATION
3. ROOM NUMBERING AND DIMENSIONIG APPEARS ON THE ENLARGED AREA VIEWS
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-100
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
D . G
R
IF
FI
N
C . G
AN
T
M . C
H
IL
D S
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
C O
M
PO
SI
TE
F
LO
O R
P
LA
N
1" = 30'-0"A-100
1 COMPOSITE FLOOR PLAN
30' 60'0
SCALE: 1"=30'
15'
M
AR
K D
F
E
A-301
D
C
B
A-301
2B
112C
2E
H
INSULATED METAL HANGAR DOORS (TYP.)
5'-0" SAFETY LANE (PAINTED)
AIRCRAFT OUTLINE (TYP.)
5'
0"
M
AT
C H
LI
N
E "A
89 SF
FIRE
SUPPRESSION
F-1
F-
E
INSULATED METAL
HANGAR DOORS (TYP.)
5'-0" SAFETY LANE (PAINTED)
AIRCRAFT OUTLINE (TYP.)
AIRCRAFT MODULE
LINE, PAINTED (TYP)
5'-0" SAFETY LANE (PAINTED)
56,727 SF
HANGAR BAY
56,727 SF
HANGAR BAY
EA
EA
EA
1'
0"
TRENCH DRAIN (TYP.)
2 3 4 5
AIRCRAFT MODULE
LINE, PAINTED (TYP)
HANDWASH STATION
F.3
G
1.2
A-501
PIPE BOLLARDS
EC
EC
EC
EC
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
KEY PLAN
PLAN NORTH
A B C D
F
NOTES:
1. SEE A-100 FOR OVERALL DIMENSIONING
2. ALL CHANGES IN FLOOR MATERIALS SHALL OCCUR AT THE
CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION
UNLESS NOTED OTHERWISE
3. REFER TO SHEET A-602 & SPECIFICATION 09 06 00 FOR ROOM FINISH
SCHEDULES AND MATERIALS
4. SEE FIRE PROTECTION SHEETS FOR LOCATIONS OF FIRE AND
SMOKE RATED WALLS AND PARTITIONS AND FIRE EXTINGUISHER LOCATIONS
5. PROVIDE GWB CONTROL JOINTS @ 30'-0" OC MAX SPACING ON ALL
EXPOSED GWB SURFACES. PROVIDE AT CORNERS OF WINDOWS &
DOOR OPENINGS OR EDGES OF CEILING FEATURES WHENEVER POSSIBLE.
6. SEE ELECTRICAL SHEETS FOR GROUNDING POINT DETAILS.
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-101
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"A
AN
N
O
TA
TI
VE
1/8" = 1'-0"A-101
1 FLOOR PLAN ANNOTATIVE - AREA "A" 8'4' 16'0
SCALE: 1/8"=1'-0"
M
AR
K D
KEY PLAN
PLAN NORTH
A B C D
F
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
NOTES:
1. SEE A-100 FOR OVERALL DIMENSIONING
2. ALL CHANGES IN FLOOR MATERIALS SHALL OCCUR AT THE
CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION
UNLESS NOTED OTHERWISE
3. REFER TO SHEET A-602 & SPECIFICATION 09 06 00 FOR ROOM FINISH
SCHEDULES AND MATERIALS
4. SEE FIRE PROTECTION SHEETS FOR LOCATIONS OF FIRE AND
SMOKE RATED WALLS AND PARTITIONS AND FIRE EXTINGUISHER LOCATIONS
5. PROVIDE GWB CONTROL JOINTS @ 30'-0" OC MAX SPACING ON ALL
EXPOSED GWB SURFACES. PROVIDE AT CORNERS OF WINDOWS &
DOOR OPENINGS OR EDGES OF CEILING FEATURES WHENEVER POSSIBLE.
6. SEE ELECTRICAL SHEETS FOR GROUNDING POINT DETAILS.
A
A-302
F
E
11 12
D
C
B
2F
H
M
AT
C H
LI
N
E "A
INSULATED METAL
HANGAR DOORS (TYP.)
5'-0" SAFETY LANE (PAINTED)
AIRCRAFT
OUTLINE (TYP.)
AIRCRAFT MODULE
LINE, PAINTED (TYP)
5'-0" SAFETY LANE
(PAINTED)
ED
9A
V-
ED
ED
HANDWASH STATION
56,727 SF
HANGAR BAY
TRENCH DRAIN (TYP)
8 9 10
F.3
G
10.8 12.2
13.7
A-501
A-501
2P
EC 131 SF
VEST
V-3
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-102
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
XX
X
YY
Y
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"B
AN
N
O
TA
TI
VE
8'4' 16'0
SCALE: 1/8"=1'-0"1/8" = 1'-0"A-102
1 FLOOR PLAN - ANNOTATIVE - AREA "B"
M
AR
K D
A B C D
F
NOTES:
1. SEE A-100 FOR OVERALL DIMENSIONING
2. ALL CHANGES IN FLOOR MATERIALS SHALL OCCUR AT THE
CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION
UNLESS NOTED OTHERWISE
3. REFER TO SHEET A-602 & SPECIFICATION 09 06 00 FOR ROOM FINISH
SCHEDULES AND MATERIALS
4. SEE FIRE PROTECTION SHEETS FOR LOCATIONS OF FIRE AND
SMOKE RATED WALLS AND PARTITIONS AND FIRE EXTINGUISHER LOCATIONS
5. PROVIDE GWB CONTROL JOINTS @ 30'-0" OC MAX SPACING ON ALL
EXPOSED GWB SURFACES. PROVIDE AT CORNERS OF WINDOWS &
DOOR OPENINGS OR EDGES OF CEILING FEATURES WHENEVER POSSIBLE.
6. SEE ELECTRICAL SHEETS FOR GROUNDING POINT DETAILS.
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
A
F
E
D
C
B
2G
M
AT
C H
LI
N
E "B
INSULATED METAL HANGAR DOORS (TYP.)
5'-0" SAFETY LANE (PAINTED)
AIRCRAFT OUTLINE (TYP.)
AIRCRAFT MODULE
LINE, PAINTED (TYP)
64' - 0"
5'
0"
38 SF
VEST
V-2
34 SF
JAN
J-1
J-
V-
ED
M
AT
C H
LI
N
E "C
MATCHLINE "D"
56,727 SF
HANGAR BAY
TRENCH DRAIN (TYP)
13 14 15 16
AIRCRAFT MODULE
LINE, PAINTED (TYP)
HANDWASH STATION
F.3
G
10.8 12.2
A-501
A-501
2P
H
EC
1' - 5 3/8"
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-103
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"C
AN
N
O
TA
TI
VE
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0"A-103
1 FLOOR PLAN - ANNOTATIVE - AREA "C"
M
AR
K D
NOTES:
1. SEE A-100 FOR OVERALL DIMENSIONING
2. ALL CHANGES IN FLOOR MATERIALS SHALL OCCUR AT THE
CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION
UNLESS NOTED OTHERWISE
3. REFER TO SHEET A-602 & SPECIFICATION 09 06 00 FOR ROOM FINISH
SCHEDULES AND MATERIALS
4. SEE FIRE PROTECTION SHEETS FOR LOCATIONS OF FIRE AND
SMOKE RATED WALLS AND PARTITIONS AND FIRE EXTINGUISHER LOCATIONS
5. PROVIDE GWB CONTROL JOINTS @ 30'-0" OC MAX SPACING ON ALL
EXPOSED GWB SURFACES. PROVIDE AT CORNERS OF WINDOWS &
DOOR OPENINGS OR EDGES OF CEILING FEATURES WHENEVER POSSIBLE.
6. SEE ELECTRICAL SHEETS FOR GROUNDING POINT DETAILS.
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
KEY PLAN
PLAN NORTH
A B C D
F
A
F
E
D
C
B
2H
112K
112L
112N
5'-0" SAFETY LANE (PAINTED)
89 SF
FIRE
SUPPRESSION
F-2
INSULATED METAL HANGAR DOORS (TYP.)
5'-0" SAFETY LANE (PAINTED)
AIRCRAFT
OUTLINE (TYP.)
AIRCRAFT MODULE
LINE, PAINTED (TYP)
5'-0" SAFETY LANE (PAINTED)
EC
F-
56,727 SF
HANGAR BAY
EA
EA
EA
TRENCH DRAIN (TYP)
19 20 21
HANDWASH STATION
F.3
G
21.8
A-501
H
PIPE BOLLARDS
EC
EC
EC
EC
E
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-104
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"D
AN
N
O
TA
TI
VE
8'4' 16'0
SCALE: 1/8"=1'-0"1/8" = 1'-0"A-104
1 FLOOR PLAN - ANNOTATIVE - AREA "D"
M
AR
K D
A B C D
F
NOTES:
1. SEE A-100 FOR OVERALL DIMENSIONING
2. ALL CHANGES IN FLOOR MATERIALS SHALL OCCUR AT THE
CENTER LINE OF THE DOOR PANEL IN THE CLOSED POSITION
UNLESS NOTED OTHERWISE
3. REFER TO SHEET A-602 & SPECIFICATION 09 06 00 FOR ROOM FINISH
SCHEDULES AND MATERIALS
4. SEE FIRE PROTECTION SHEETS FOR LOCATIONS OF FIRE AND
SMOKE RATED WALLS AND PARTITIONS AND FIRE EXTINGUISHER LOCATIONS
5. PROVIDE GWB CONTROL JOINTS @ 30'-0" OC MAX SPACING ON ALL
EXPOSED GWB SURFACES. PROVIDE AT CORNERS OF WINDOWS &
DOOR OPENINGS OR EDGES OF CEILING FEATURES WHENEVER POSSIBLE.
6. SEE ELECTRICAL SHEETS FOR GROUNDING POINT DETAILS.
X WALL TYPE SEE
SHEETS A-601
SYMBOLS LEGEND
X WINDOW TYPE SEE
SHEETS A-606
000 ROOM NUMBER
DOOR NUMBER SEE SHEETS
A-603 FOR DOOR SCHEDULE
LOUVER SEE-607X
MEJ MASONRY EXPANSION JOINT
DS DOWN SPOUT
AA A
A-302
11 12
ED
1,278 SF
WORK ROOM
140 SF
BREAK
250 SF
WOMEN
288 SF
MEN
195 SF
CORR
C-1
38 SF
VEST
V-2
415 SF
MECHANICAL
34 SF
JAN
J-1
232 SF
CONFERENCE
143 SF
OFFICE
141 SF
OFFICE
157 SF
RECEPTION
74 SF
VEST.
V-1
137 SF
COMM
210 SF
ELECTRICAL
226 SF
CONFERENCE
9A
109B
V-
104110
J-
V-
C -1
D
E D
D
C
C
D
C
A G
H
H
H H
ED
B
G H
F
B
D
B
B B
B
B
B
B
H H
G
B
B E
E
ED
ED
A-402
A-402
A-4031
A
B
B
F
H MATCHLINE "D"H
A
EA
EA
EB
EBEB
EBEA
EA
EB
EA EB
F
B
K
10 13 14
493 SF
FIRE
SUPPRESSION
HH
EC
C
PRINT AREA
A-311
A-501
A-501
9C
EC 131 SF
VEST
V-3
WALK-OFF MAT
1' - 5 3/8"
A-210
ROOF ACCESS LADDER
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-105
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"F
AN
N
O
TA
TI
VE
8'4' 16'0
SCALE: 1/8"=1'-0"
1/8" = 1'-0"A-105
1 FLOOR PLAN ANNOTATIVE - AREA "F"
M
AR
K D
F
E
D
C
B
11' - 3 1/4"
1'
1/ 4"
2' - 0 3/4"
13' - 4"
7 5/8" 8'
0"
LOCATE ACCESS DOOR
IN CENTER OF PANEL (TYP)
56,727 SF
HANGAR BAY
89 SF
FIRE
SUPPRESSION
F-1
4'
1/
2"
2 3 4 5
7 5/8" 7 5/8"
F.3
G
1.2
2'
0"
1'
/4
9' - 2 1/2"
64' - 0"
8'
6"
10' - 0"
64' - 0"
91' - 9 1/2"
7 5/8" 7 5/8"
5/
8"
29' - 9 1/2"
5'
0" 5'
0"
5' - 0"5' - 0"
5'
0"
5'
0" 5'
0"
5' - 0"
62' - 0"
KEY PLAN
PLAN NORTH
A B C D
F
NOTES:
1. ALL DIMENSIONS ARE NOMINAL UNLESS NOTED OTHERWISE
2. ALL DOORS ARE LOCATED 4 INCHES OFFSET FROM ADJACENT
WALL FINISH SURFACE UNLESS OTHERWISE NOTED
3. DIMENSIONS ARE TO CENTERLINE OF COLUMNS, FACE OF STEEL,
FACE OF MASONRY, OR FACE OF STUDS UNLESS NOTED OTHERWISE
4. ROUGH OPENINGS FOR HOLLOW METAL FRAMES "FO" INDICATES FRAME
OPENING, ADD 1/4" CLEARANCE ON BOTH SIDES OF FRAME.
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-107
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T D es ig ne r
Au th or
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"A
D
IM
EN
SI
O N
AL
1/8" = 1'-0"A-107
1 FLOOR PLAN -DIMENSIONAL - AREA "A"
8'4' 16'0
SCALE: 1/8"=1'-0"
M
AR
K D
F
E
11 12
D
C
B
M
AT
C H
LI
N
E "A
M
AT
C H
LI
N
E "B
LOCATE ACCESS DOORS IN
CENTER OF PANELS (TYP.)
56,727 SF
HANGAR BAY
7 8 9 10
F.3
G
10.8 12.2
13.7
15' - 0"
7 5/8" 7 5/8"13' - 8 3/4"
4'
1/
2"
1' - 3 7/8" 1' - 3 7/8"
64' - 0" 64' - 0"
6' - 5 1/2"
15' - 0"
6' - 5 1/2"
2' - 3 1/2"
7' - 9"18' - 3" 5' - 8"
35' - 4 1/2"
5' - 0"
5' - 0" 5' - 0"
5'
0"
5'
0"5' - 0"
5' - 0"
5'
0"
5'
0"
5'
0"
131 SF
VEST
V-3
NOTES:
1. ALL DIMENSIONS ARE NOMINAL UNLESS NOTED OTHERWISE
2. ALL DOORS ARE LOCATED 4 INCHES OFFSET FROM ADJACENT
WALL FINISH SURFACE UNLESS OTHERWISE NOTED
3. DIMENSIONS ARE TO CENTERLINE OF COLUMNS, FACE OF STEEL,
FACE OF MASONRY, OR FACE OF STUDS UNLESS NOTED OTHERWISE
4. ROUGH OPENINGS FOR HOLLOW METAL FRAMES "FO" INDICATES FRAME
OPENING, ADD 1/4" CLEARANCE ON BOTH SIDES OF FRAME.
KEY PLAN
PLAN NORTH
A B C D
F
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
FI
LE
N
AM
E:
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
PR
O
JE
C
T N
U M
BE
R
A
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
D
ES
C R
IP
TI
O N
A-108
AI
R
C R
AF
T
AN
D
F
LI
G H
T
EQ
U
IP
M
EN
T
BU
IL
D
IN
G
M O
BI
LE
D
IS
TR
IC
T C
. G
AN
T
C . G
AN
T
C he ck er
JU
N
E
W
0R
M H
Y2
R
ED
ST
O
N E
AR
SE
N
AL
, A
LA
BA
M
A
SA
IN
T
JO
SE
PH
S
TR
EE
T
M O
BI
LE
A L
FL
O
O R
P
LA
N
AR
EA
"B
D
IM
EN
SI
O N
AL
1/8" = 1'-0"A-108
1 FLOOR PLAN -DIMENSIONAL - AREA "B" 8'4' 16'0
SCALE: 1/8"=1'-0"
M
AR
K D
F
E
11 12
D
C
B
5' - 6"
M
AT
C H
LI
N
E "B
M
AT
C H
LI
N
E "C
MATCHLINE "D"
56,727 SF
HANGAR BAY
13 14 15 16
F.3
G
10.8 12.2
15' - 0"
7 5/8" 7 5/8"13' - 8 3/4"
1' - 3 7/8" 1' - 3 7/8"
LOCATE ACCESS DOORS IN
CENTER OF PANELS (TYP.)
6' - 5 1/2"
15' - 0"
6' - 5 1/2" 64' - 0" 64' - 0"
8'
6"
7' - 9" 7' - 1 1/2"5' - 8" 8' - 10"
3'
7/
8"
4'
0"
5' - 0" 5' - 0"
5'
0"5' - 0"
5' - 0"
5'
0"
5'
0"
36' - 8" 5' - 0"
5'
0"
2' - 6"
NOTES:
1. ALL DIMENSIONS ARE NOMINAL UNLESS NOTED OTHERWISE
2. ALL DOORS ARE LOCATED 4 INCHES OFFSET FROM ADJACENT
WALL FINISH SURFACE UNLESS OTHERWISE NOTED
3. DIMENSIONS ARE TO CENTERLINE OF COLUMNS, FACE OF STEEL,
FACE OF MASONRY, OR FACE OF STUDS UNLESS NOTED OTHERWISE
4. ROUGH OPENINGS FOR HOLLOW METAL FRAMES "FO" INDICATES FRAME
OPENING, ADD 1/4" CLEARANCE ON BOTH SIDES OF FRAME.
KEY PLAN
PLAN NORTH
A B C D
F
US Army Corps of Engineers
SHEET ID
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .