DLA_RRAD_GPW_RTA_Drawings_2017-10-05_Part2.pdf
PDF 40 MB Posted
- Attached to
- DLA General Purpose Warehouse
- Solicitation number
- W9126G-18-R-0135
About this file
Drawings Part 2
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Clarifications.docx | DOCX document | |
| am_4.pdf | ||
| am_3.pdf | ||
| BI_Responses.pdf | ||
| Site_Visit_Attendees.pdf | ||
| g18r0135_RFP_Final_v3.pdf | ||
| g18r0135_RFP_Final_v2.pdf | ||
| DLA_RRAD_GPW_RTA_Drawings_2017-10-05_Part1.pdf | ||
| DLA_RRAD_GPW_RTA_Drawings_2017-10-05_Part3.pdf | ||
| DLA_RRAD_GPW_RTA_Drawings_2017-10-05_Part4.pdf | ||
| g18r0135_RFP_Final.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MIN MINIMUM
STR
T/FLR
T/SLAB
NS
NTS
o/c
OPNG
OH
PSI
PSF
PVC
R
REPL
REQD
SCHD
SIM
SPEC
STD
SQ
THK
THD
TD
TSF
TYP
T&B
T/FTG
T/STL
T/WALL
UNO
VIF
W/
WP
WS
NIC
ELEVATION TARGET
SECTION NUMBER
SHEET NUMBER
SIMPLE SHEAR CONNECTION
FULL MOMENT CONNECTION
AT
AND
PERCENT
POUND, NUMBER
NEAR SIDE
NOT TO SCALE
ON CENTER(S)
OPENING
OPPOSITE HAND
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
POLYVINYL CHLORIDE
RADIUS
REPLACE, REPLACEMENT
REQUIRED
SCHEDULE(D)
SIMILAR
SPECIFICATIONS
STANDARD
STRUCTURE, STRUCTURAL
SQUARE
THICK
THREAD
TRENCH DRAIN
TONS PER SQUARE FOOT
TYPICAL
TOP AND BOTTOM
TOP OF FLOOR
TOP OF FOOTING
TOP OF STEEL
TOP OF SLAB
TOP OF WALL
UNLESS NOTED OTHERWISE
VERIFY IN FIELD
WITH
WORKING POINT
WATER STOP
NOT IN CONTRACT
C/C OR CC
ABBREVIATIONS & SYMBOLS
CONT
MECH
MEP
MFR
DET
DIA
D N
DWG
DWL
EA
EF
ELEV
EQUIP
EW
EXIST, (E)
EXP
EXT
FDFD
N
FBO
FIN
FLR
FS
FTFT
G
GC
HEX
HORIZ
HP
HS
ID
IN
INFO
INV
JT
K
KSI
LOC
LP
LTWT
MAX
ADJ
ADDL
AFF
B/E
BLDG
BOT
BS
BSMT
CANT
CL
COL
CONC
CONN
CONST
CONTINUOUS
MECHANICAL
MECHANICAL,
ELECTRICAL & PLUMBING
MANUFACTURER
DETAIL
DIAMETER
DOWN
DRAWING(S)
DOWEL
EACH
EACH FACE
ELEVATION
EQUIPMENT
EACH WAY
EXISTING
EXPANSION
EXTERIOR
FLOOR DRAIN
FOUNDATION
FURNISHED BY OTHERS
FINISHED
FLOOR
FAR SIDE
FOOT OR FEET
FOOTING
GENRAL CONTRACTOR
HEXAGONAL
HORIZONTAL
HIGH POINT
HIGH STRENGTH
INSIDE DIAMETER
INCH OR INCHES
INFORMATION
INVERT
JOINT
KIP (ONE THOUSAND POUNDS)
KIPS PER SQUARE INCH
LOCATION
LOW POINT
LIGHT WEIGHT
MAXIMUM
ADJACENT
ADDITIONAL
ABOVE FINISHED FLOOR
BETWEEN
BUILDING
BOTTOM
BOTH SIDES
BASEMENT
CANTILEVER
CENTER TO CENTER
CENTER LINE
COLUMN
CONCRETE
CONNECTION
CONSTRUCTION
ANCHOR BOLT
( ) DESIGNATES NUMBER OF SHEAR CONNECTORS
[ ] DESIGNATES CONNECTION REACTION
< > DESIGNATES CAMBER
S100
BOD BOTTOM OF DECK
EOD EDGE OF DECK
L ANGLE
CLR CLEAR
PJF PREMOLDED JOINT FILLER
N/A NOT APPLICABLE
T/BM TOP OF BEAM
B/FTG BOTTOM OF FOOTING
EOS EDGE OF SLAB
B/BM BOTTOM OF BEAM
TG TRANSFER GIRDER
PT POST-TENSION(ED)
SOG SLAB-ON-GRADE
T/COL TOP OF BEAM
DIP DUCTILE IRON PIPE
GEN GENERAL
PVMT PAVEMENT
PCC PORTLAND CEMENT CONCRETE
RD ROOF DRAIN
REINF REINFORCING
RET RETAINING
TEMP TEMPORARY
SPA SPACING
HCA HEADED CONCRETE ANCHOR
ARC
H ARCHITECTURAL
EL ELEVATION
LWC LIGHTWEIGHT CONCRETE
ELEVATION NUMBER
SHEET NUMBERS100
DBA DEFORMED BAR ANCHOR
GALV GALVANIZED
KSF KIPS PER SQUARE FOOT
STL STEEL
BM BEAM
LNG LONGITUDINAL
REM REMOVAL
SS STAINLESS STEEL
AR ANCHOR ROD
CJ CONSTRUCTION JOINT
EJ EXPANSION JOINT
OF OUTSIDE FACE
OPP OPPOSITE
PL PLATE
PROP PROPOSED
WWF WELDED WIRE FABRIC
W/O WITHOUT
COORD COORDINATE
HDPE HIGH DENSITY POLYETHYLENE
VERT VERTICAL
NWC NORMAL WEIGHT CONCRETE
BAL BALANCE
CMU CONCRETE MASONRY UNIT
CP COMPLETE PENETRATION
AB US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T
B D
S O
L
IC
IT
A
T
IO
N N
O
W G
-1 -D
-0
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T R
E E
T F
O R
T W
O R
T H
T
E X
A S
A U
R B
A N
E K
A U
R B
A N
E K
C B
O W
E
K S
H E
R L O
C K
G P
W -D
M M
S .r v t
D L A
G E
N E
R A
L P
U R
P O
S E
W A
R E
H O
U S
E
G P
W
R E
D R
IV
E
R A
R M
Y D
E P
O T
R
R A
D
T E
X A
S
S T
R U
C T
U R
A L
N
. M
IC
H
IG
A N
A V
E S
U
IT
E
C H
IC
A
G O
, I L w w w .e x p
F e d e ra l.c o m p ro j.
n o C
H I- -A
S-001
S T
R U
C T
U R
A L N
O T
E S
O
C T
READY TO ADVERTISE
DESIGN CODE SUMMARY TABLE
IBC 2015 ICC INTERNATIONAL BUILDING CODE, 2015
ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, 2010
AISC 325-11 STEEL CONSTRUCTION MANUAL, 14th EDITION
AISC 360-10 SPECIFICATIONS FOR STRUCTURAL STEEL BUILDINGS, 2010
AISC 327-12 SEISMIC DESIGN MANUAL, 2nd EDITION (FOR R > 3.0)
AISC 341-10 SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS (FOR R > 3.0)
AISC 303-10 CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, 2010
ACI 318-14 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE, 2014
ACI 301-16 SPECIFICATIONS FOR STRUCTURAL CONCRETE, 2016
ACI SP-066(04) ACI DETAILING MANUAL (ACI 315-99, ACI 315R-04), 2004
TMS MSJC-13 BUILDING CODE REQUIREMENTS & SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530/530.1), 2013
AWS AMERICAN WELDING SOCIETY, STRUCTURAL WELDING CODE, LATEST EDITION
SDI C-11 / RD-10 STANDARD FOR COMPOSITE STEEL FLOOR DECK, 2011 / STANDARD FOR STEEL ROOF DECK, 2010
AISI S100-12 SPECIFICATIONS FOR DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS, 2012
UFC 3-301-01 UNIFIED FACILITIES CRITERIA - STRUCTURAL ENGINEERING (2016)
UFC 3-310-04 UNIFIED FACILITIES CRITERIA - SEISMIC DESIGN FOR BUILDINGS (2016)
UFC 4-010-01 DoD MINIMUM ANTITERRORISM STANDARDS FOR BUILDINGS (2013)
UFC 3-320-06A CONCRETE FLOOR SLABS ON GRADE SUBJECTED TO HEAVY LOADS (2005)
UFC 4-440-01 WAREHOUSE AND STORAGE FACILITIES (2014)
SWD-AEIM SOUTHWESTERN DIVISION ARCHITECTURAL AND ENGINEERING INSTRUCTIONS MANUAL (2003)
ICC-500 STANDARD FOR THE DESIGN AND CONSTRUCTION OF STORM SHELTERS, ICC/NSSA, 2014
FEMA P-361 SAFE ROOMS FOR TORNADOES AND HURRICANES, FEMA, 3rd EDITION, 2015
MINIMUM ENVIRONMENTAL LOADS
ROOF SNOW LOADS
GROUND SNOW, Pg = 5 PSF
SNOW DRIFT AT ELEVATION CHANGES (PER ASCE-7, Ch. 7.7) SEE DIAGRAMS
MINIMUM FLAT SNOW LOAD (Pg*I for Pg<20, 20*I for Pg>20) 5 PSF
IMPORTANCE FACTOR (RISK CATEGORY II), Is = 1.0
EXPOSURE FACTOR, Ce = 1.1
THERMAL FACTOR, Ct = 1.0
WIND LOADS:
BASIC WIND SPEED, v = 115 mph
EXPOSURE CATEGORY C
TOPOGRAPHIC FACTOR, Kzt 1.0
DIRECTIONALITY FACTOR, Kd .85
IMPORTANCE FACTOR (RISK CATEGORY II), Iw 1.0
ENCLOSURE CLASSIFICATION: ENCLOSED, GCpi +/- 0.18
EARTHQUAKE LOADS
Ss (Sds) 0.138 (0.148) g
S1 (Sd1) 0.076 (0.122) g
SOIL SITE CLASSIFICATION D
SEISMIC DESIGN CATEGORY, SDC B (R=3)
IMPORTANCE FACTOR (RISK CATEGORY II), Ie 1.00
SFRS: B.9 - ORDINARY PRECAST SHEAR WALLS R = 4.0, Cd = 4
SEISMIC ANALYSIS PROCEDURE EQ. LAT FORCE
DRIFT
WIND DRIFT BLDG HEIGHT "H" LIMIT H/500
ALLOWABLE SEISMIC STORY "h" DRIFT (ASCE 7 TABLE 12.12-1) 0.020 h(sx)
COMPONENTS &
CLADDING
WIND LOADS - C&C PER ASCE 7-10, CHAPTER 26 -
SEISMIC LOADS - C&C PER ASCE 7-10, CHAPTER 13 -
TORNADO SAFE ROOM
BASIC WIND SPEED, v = 250 mph
EXPOSURE CATEGORY C
TOPOGRAPHIC FACTOR, Kzt 1.00
DIRECTIONALITY FACTOR, Kd 1.00
ROOF LIVE LOAD (UN-REDUCIBLE) 100 PSF
15-LB 2x4 LUMBER MISSILE SPEED (VERTICAL/HORIZONTAL
SURFACES)
100/67 mph
ATFP (ANNEX ONLY)
LEVEL OF PROTECTION VERY LOW (VLOP)
STANDOFF DISTANCE - LOADBEARING CONCRETE WALL
CONSTRUCTION
16 FT
OCCUPANCY INHABITED
APPLICABLE EXPLOSIVE WEIGHT II
CONCENTRATED LOAD ANY DIRECTION (WHICHEVER IS GREATER) 200 LBS
SIMULTANEOUS VERTICAL & HORIZONTAL THRUST TOP OF RAILING 50 PLF
GUARDRAIL/HANDRAIL
FORKLIFT, MAX LOADED WHEEL / AXLE 8.38k/16.75k
RACK AREAS (3,000 LBS PALLET, 2 PER SHELF, 5 SHELF PER RACK) 1,000 PSF
WAREHOUSE FLOOR (NON-SPECIFIED) 200 PSF
LOADING DOCK & RAMPS 500 PSF
MECHANICAL AREAS (NON-REDUCIBLE) 150 PSF
LOBBIES, VESTIBULES, CORRIDORS & STAIRWAYS (NON-REDUCIBLE) 100 PSF
BATTERY ROOM 75 PSF
OFFICE 75 PSF
RESTROOMS 75 PSF
BREAK ROOMS 80 PSF
FLOOR
MINIMUM LIVE LOAD, Lr (UNREDUCIBLE) 20 PSF
ROOF
LIVE LOADS
STEEL FRAMING, GUARDRAIL, HANDRAIL, CONCRETE FILLED PANS 40 PSF
STEEL FRAMING, GUARDRAIL, HANDRAIL, THREADS 15 PSF
STAIRS
BRICK VENEER WITH STEEL STUD BACK-UP 50 PSF
PRECAST PANEL, INSULATION (PER INCH THICKNESS) 1.5 PSF
PRECAST PANEL, CONCRETE (PER INCH THICKNESS) 12.5 PSF
CURTAIN WALLS 15 PSF
EXTERIOR WALLS
VERTICAL SCREEN ALLOWANCE (PER FOOT OF HEIGHT) 15 PSF
HOUSEKEEPING CONCRETE PADS (PER INCH THICKNESS) 12.5 PSF
MECHANICAL
STRUTCTURAL FRAMING DEAD LOADS SEE PLANS
CEILING ALLOWANCE (ANNEX ONLY) 5 PSF
LIGHTING / ELECTRICAL ALLOWANCE 1 PSF
SPRINKLER ALLOWANCE (MAX PIPE 6" DIA) 4 PSF
HVAC ALLOWANCE 1 PSF
RIGID INSULATION (1.5 PSF PER INCH) 3 PSF
ROOF BOARD (MECHANICALLY ATTACHED) 1 PSF
TPO SINGLE PLY ROOF (FULLY ADHERED OR FASTENED) 2 PSF
ROOF
SUPERIMPOSED DEAD LOADS
MINIMUM GRAVITY LOADS
15. IN ADDITION TO PROVISIONS OUTLINED IN THE STANDARD TERMS AND GENERAL CONDITIONS FOR SUBMITTALS, ALL RE-SUBMITTALS SHALL INCORPORATE COMMENTS MADE BY A/E ON PREVIOUS REVIEW(S). ANY CHANGES MADE FROM PREVIOUS SUBMITTAL MUST BE BUBBLED AND/OR CLEARLY IDENTIFIED. NON-COMPLIANT SUBMITTALS MAY BE REJECTED
AT DISCRETION OF CONTRACTING OFFICER AND/OR GOVERNMENT.
14. CONSTRUCTION MATERIALS SHALL BE SPREAD OUT IF PLACED ON STRUCTURAL FRAME SUCH THAT THE LOADING DOES NOT EXCEED THE DESIGN LIVE LOADS. PROVIDE SHORING AND BRACING WHERE DESIGN STRENGTH HAS NOT BEEN
ATTAINED OR STRUCTURE IS NOT COMPLETE.
13. CONTRACTOR SHALL DETERMINE THE LOCATION OF UTILITY SERVICES IN AREAS TO BE EXCAVATED BEFORE BEGINNING EXCAVATION. EXERCISE CAUTION IN EXCAVATING AND TRENCHING. ANY DAMAGE TO THE EXISTING UTILITIES CAUSED BY CONTRACTOR SHALL BE REPAIRED BY THE CONTRACTOR TO THE SATISFACTION OF THE CONTRACTING OFFICE AND AT NO
COST TO THE GOVERNMENT.
12. SHALL INVESTIGATE THE SITE DURING CLEARING AND EXCAVATION FOR UNSUITABLE CONDITIONS, UNCONSOLIDATED AND UNDOCUMENTED FILLS, BURIED STRUCTURES, UTILITIES, ETC. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CONTRACTING OFFICER OF ANY SITE CONDITIONS NOT REFLECTED ON THE DRAWINGS OR DIFFERENT FROM MAXIMUM OR MINIMUM DIMENSIONS INDICATED, INCLUDING CONFLICT IN GRADES, ADVERSE SOIL CONDITIONS, GROUND WATER
PRESENT, DEEPENED FOOTINGS, UNCOVERED AND UNEXPECTED UTILITY LINES, ETC.
11. CONTRACTOR SHALL INVESTIGATE THE SITE DURING CLEARING AND EXCAVATION FOR UNSUITABLE CONDITIONS, UNCONSOLIDATED AND UNDOCUMENTED FILLS, BURIED STRUCTURES, UTILITIES, ETC. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE CONTRACTING OFFICER OF ANY SITE CONDITIONS NOT REFLECTED ON THE DRAWINGS OR DIFFERENT FROM MAXIMUM OR MINIMUM DIMENSIONS INDICATED, INCLUDING CONFLICT IN GRADES, ADVERSE SOIL CONDITIONS, GROUND WATER PRESENT, DEEPENED FOOTINGS, UNCOVERED AND UNEXPECTED UTILITY LINES, ETC.
10. ASTM REFERENCES ARE FOR LATEST REVISIONS AND ISSUE, UNLESS NOTED OTHERWISE.
9. IN CASES WHERE MECHANICAL OR ELECTRICAL EQUIPMENT LOADING LISTED ON THE MANUFACTURER'S PRODUCT DATA SHEET EXCEEDS DESIGN LOADS INDICATED ON THE PLANS, CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER
PRIOR TO PROCEEDING WITH WORK.
8. JOIST MANUFACTURER TO COORDINATE EXACT WEIGHT, WEIGHT DISTRIBUTION, SIZE AND LOCATION OF ROOF MECHANICAL UNITS/DUCTS AND VERIFY SIZE OF OPEN-WEB STEEL JOIST SHOWN ON THE DRAWINGS AT NO ADDITIONAL COST TO THE GOVERNMENT. OPEN WEB JOIST & JOIST GIRDER SIZES SHOWN SHALL BE CONSIDERED MINIMUM SIZES
REQUIRED.
6. EXCEPT AS NOTED HEREIN, REFER TO MEP DRAWINGS FOR THE FOLLOWING, BUT NOT LIMITED TO:
A) PIPE RUNS, SLEEVES, HANGERS, EQUIPMENT, SLAB OPENINGS, NOT SHOWN OR NOTED HEREIN.
B) ELECTRICAL CONDUIT, BOXES, OUTLETS.
C) CONCRETE INSERTS FOR ELECTRICAL, MECHANICAL, AND PLUMBING FIXTURES.
D) SIZE AND LOCATION OF MACHINE AND EQUIPMENT BASES. CONTRACTOR'S ENGINEER SHALL DESIGN SEISMIC
ANCHORAGE FOR MECHANICAL AND ELECTRICAL EQUIPMENT PER SPECIFICATIONS.
5. EXCEPT AS NOTED HEREIN, REFER TO ARCHITECTURAL DRAWINGS FOR THE FOLLOWING, BUT NOT LIMITED TO:
A) SIZE AND LOCATION OF DOOR AND WINDOW OPENINGS
B) SIZE AND LOCATION OF INTERIOR AND EXTERIOR NONBEARING PARTITIONS
C) SIZE AND LOCATION OF CURBS, FLOOR DRAINS, SLOPES, DEPRESSED AREAS, CHANGES IN LEVEL, RAMPS, CHAMFERS
GROOVES, INSERTS, ETC.
D) SIZE AND LOCATION OF FLOOR AND ROOF OPENINGS IF NOT DIMENSIONED HEREIN.
E) FLOOR AND ROOF FINISHES
F) STAIR FRAMING AND DETAILS.
G) DIMENSIONS NOT SHOWN ON STRUCTURAL DRAWINGS.
4. NO PIPES OR DUCTS SHALL BE PLACED IN OR PENETRATE STRUCTURAL MEMBERS UNLESS SPECIFICALLY DESIGNED AND
DETAILED.
3. ALL WORK NOT DETAILED OR NOTED SHALL BE CONSTRUCTED IN ACCORDANCE WITH OTHER SIMILAR WORK SHOWN ON THE DRAWINGS AND TYPICAL DETAILS. DIMENSIONS SHALL TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL
DETAILS. DRAWINGS SHALL NOT BE SCALED FOR CONSTRUCTION PURPOSES.
2. THE DRAWINGS AND SPECIFICATIONS REPRESENT THE COMPLETED STRUCTURE. THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES AND MEANS NECESSARY TO PROTECT PERSONS AND STRUCTURES DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT BE LIMITED TO BRACING, SHORING, ETC. THE CONTRACTOR SHALL RETAIN A LICENSED PROFESSIONAL ENGINEER TO DESIGN THE LATERAL SUPPORT SYSTEM REQUIRED TO RESIST THE LATERAL LOADS AND FOR ALL STABILITY OF THE STRUCTURE UNTIL COMPLETION. THE CONTRACTOR SHALL FURNISH AND PROVIDE THE NECESSARY BRACING AND SUPPORTS DURING CONSTRUCTION AND IS RESPONSIBLE FOR THE OVERALL STABILITY OF THE STRUCTURE UNTIL COMPLETION. OBSERVATION BY THE A/E OR
CONTRACTING OFFICER DOES NOT INCLUDE REVIEW OF THESE MEASURES.
1. THE CONTRACTOR SHALL EXAMINE THE STRUCTURAL DRAWINGS AND SHALL NOTIFY THE CONTRACTING OFFICER OF ANY
DISCEPANCIES BEFORE PROCEEDING WITH ANY WORK.
GENERAL NOTES
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
10/05/2017
REINFORCING BAR DEVELOPMENT AND
SPLICE LENGTH (f'c = 4 ksi & fy = 60 ksi)
BAR
SIZE
TENSION
DEVELOPMENT
& CLASS "A"
SPLICE
CLASS "B"
SPLICE
ACI STD 90
DEG HOOK
COMPRESSION
BARS
TOP
BAR
(Ldt)
OTHER
BA
(Ldo)
TOP
BAR
(Lst)
OTHER
BAR
(Lso)
EMBED-
MENT
(Ldh)
LENGTH
(Lh)
DEVELOP-
MENT
(Ldc)
SPLICE
#4
#5
#6
#7
#8
#9
#10
#11
15 12 20 16 10 8 1510
19 15 24 19 12 10 12 19
23 18 29 23 15 12 15 23
37 29 48 37 17 14 17 27
47 36 61 47 19 16 19 30
57 44 75 57 22 19 22 34
70 54 91 70 25 22 25 39
84 65 109 84 27 24 27 43
NOTES:
1. STRAIGHT DEVELOPMENT AND CLASS "B" SPLICE LENGTH SHOWN IN ABOVE
TABLE ARE BASED ON UNCOATED BARS ASSUMING BAR SPACING = 12"
WITHOUT TIES OR STIRRUPS, BAR CLEAR COVER = 1.5". NORMAL WEIGHT
CONCRETE W/ NO TRANSVERSE REINFORCEMENT AND NO EXCESS
REINFORCING IS ASSUMED.
2. STANDARD 90 DEG HOOK EMBEDMENT LENGTH IS BASED ON BAR SIDE AND
END COVER = 2.5" WITHOUT TIES AROUND HOOK.
3. FOR ALL TOP EPOXY-COATED BARS IN TENSION (SPLICED OR DEVELOPED
WITH OR WITHOUT HOOK) INCREASE VALUES IN THIS TABLE BY 30%.
4. WHEN BARS OF DIFFERENT SIZES ARE LAP SPLICED IN TENSION, SPLICE
LENGTH SHALL BE THE LARGER OF DEVELOPMENT LENGTH OF LARGER BAR
AND TENSION LAP SPLICE LENGTH OF SMALLEST BAR.
5. ALL SPLICES SHOWN ON DRAWINGS SHALL BE CLASS "B" UNO.
6. TOP BARS ARE DEFINED AS HORIZONTAL BARS WITH MORE THAN 12 INCHES
OF FRESH CONCRETE CAST BELOW THE DEVELOPMENT LENGTH ON SPLICE.
SPLICE OR DEVELOPMENT LENGTH OF
REBARS IN TENSION OR COMPRESSION
FOR CONCRETE MASONRY
SPLICE OR DEVELOPMENT LENGTH OF REBAR, IN
BAR
SIZE BAR LOCATED IN CENTER OF CMU WALL MINIMUM COVER
6" 8" 10" 12" 1 1/2" 2"
BAR SPACING 8" OR MORE
#4
#5
#6
#7
21 21 21 21 34 26
32 26 26 26 45 40
61 43 40 40 54 54
- 60 46 46 63 63
NOTES:
1. DEVELOPMENT LENGTH OF BAR IN TENSION OR
COMPRESSION DETERMINED PER ACI 530 FOR SPECIFIED
COMPRESSIVE STRENGTH OF MASONRY, f'm= 1,500 PSI.
2. IF CONCRETE COVER OR BAR SPACING DIFFERS FROM THE
TABLE, DEVELOPMENT LENGTH SHALL BE DETERMINED
INDIVIDUALLY.
3. PROVIDE LAP SPLICES OF VERTICAL REINFORCEMENT AT
SLABS.
4. FOR f'm= 2,000 PSI THE LENGTHS SHOWN IN THE TABLE MAY
BE REDUCED BY 13%.
A. SATISFACTORY MATERIALS INCLUDE SOILS CLASSIFIED PER ASTM
D 2487 AS GW, GM, GC, GP, SW, SP, SM, SC, CL, AND CH AND SHALL
BE FREE OF TRASH, DEBRIS, ROOTS OR OTHER ORGANIC MATTER,
OR STONES LARGER THAN 3”.
B. UNSATISFACTORY MATERIALS INCLUDE SOILS CLASSIFIED PER
ASTM D 2487 AS PT, OH, OL, ML, MH AND ANY OTHER MATERIALS
NOT DEFINED AS SATISFACTORY.
C. NON-EXPANSIVE SOILS SHOULD MEET THE REQUIREMENTS OF
TxDOT STANDARD SPECIFICATION FOR BASE COURSE, ITEM 247, TYPE A, GRADE 1 OR 2, WITH PLASTICITY INDEX (PI) OF 4<PI<12
WHEN TESTED IN ACCORDANCE WITH ASTM D 4318.
D. SELECT SOILS ARE SATISFACTORY MATERIAL HAVING A LIQUID
LIMIT LL < 35% OR LESS AND 8<PI<18 WHEN TESTED IN
ACCORDANCE WITH ASTM D 4318.
E. SELECT CLAY BACKFILL SHALL BE A SATISFACTORY MATERIAL
HAVING LL < 35% OR LESS AND 8<PI<20 WHEN TESTED IN
ACCORDANCE WITH ASTM D 4318 AND CLASSIFYING AS A CL IN
ACCORDANCE WITH ASTM D 2487.
F. COHESIONLESS MATERIALS INCLUDE MATERIALS CLASSIFIED IN
ASTM D 2487 AS GW, GP, SW, AND SP. COHESIVE MATERIALS
INCLUDE MATERIALS CLASSIFIED AS GC, SC, ML, CL, MH, AND CH.
MATERIALS CLASSIFIED AS GM AND SM WILL BE IDENTIFIED AS
COHESIONLESS ONLY WHEN THE FINES ARE NON-PLASTIC.
G. CAPILLARY WATER BARRIER SHALL CONSIST OF CLEAN,
CRUSHED, NONPOROUS ROCK, CRUSHED GRAVEL, OR
UNCRUSHED GRAVEL. THE MAXIMUM PARTICLE SIZE SHALL BE 1-
1/2” AND NO MORE THAN 2% BY WEIGHT SHALL PASS THE 3/16”
SIZE (NO. 4) SIEVE.
H. NON-SHRINK SELECT FILL USED IN AREAS DESIGNATED FOR NON-
EXPANSIVE FILL PLACED BENEATH FLOOR SLABS SHALL CONSIST
OF SATISFACTORY MATERIALS HAVING 4<PI<12 WHEN TESTED IN
ACCORDANCE WITH ASTM D 4318. ML SOILS ARE NOT APPROVED
FOR USE AS NON-SHRINK SELECT FILL.
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T
B D
S O
L
IC
IT
A
T
IO
N N
O
W G
-1 -D
-0
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T R
E E
T F
O R
T W
O R
T H
T
E X
A S
A U
R B
A N
E K
A U
R B
A N
E K
C B
O W
E
K S
H E
R L O
C K
G P
W -D
M M
S .r v t
D L A
G E
N E
R A
L P
U R
P O
S E
W A
R E
H O
U S
E
G P
W
R E
D R
IV
E
R A
R M
Y D
E P
O T
R
R A
D
T E
X A
S
S T
R U
C T
U R
A L
N
. M
IC
H
IG
A N
A V
E S
U
IT
E
C H
IC
A
G O
, I L w w w .e x p
F e d e ra l.c o m p ro j.
n o C
H I- -A
S-002
S T
R U
C T
U R
A L N
O T
E S
O
C T
READY TO ADVERTISE
FOUNDATION NOTES
1. BASIS OF FOUNDATION DESIGN PER FY17 DLA GENERAL PURPOSE WAREHOUSE AND OPEN STORAGE
AREAS FOUNDATION AND PAVEMENT DESIGN ANALYSIS, DATED JUNE 2017, PREPARED BY USACE
FORTH WORTH DISTRICT ENGINEERING AND CONSTRUCTION DIVISION, GEOTECHNICAL BRANCH
(CESWF-EC-G).
2. DESIGN OF FOUNDATIONS IS BASED ON ALLOWABLE SERVICE LOAD BEARING PRESSURE OF 2,000 PSF.
3. EXCAVATIONS SHALL CONFORM TO THE DIMENSIONS AND ELEVATION OF EACH STRUCTURE.
4. EXCAVATIONS SHALL INCLUDE TRENCHING FOR UTILITY AND FOUNDATION DRAINAGE SYSTEMS TO A
POINT 5 FT BEYOND THE BUILDING LINE.
5. EXCAVATIONS SHALL EXTEND SUFFICIENT DISTANCE FROM WALLS AND FOOTINGS TO ALLOW FOR
PLACING AND REMOVING FORMS.
6. EXCAVATION BELOW INDICATED DEPTHS SHALL NOT BE PERMITTED EXCEPT TO REMOVE
UNSATISFACTORY MATERIAL.
7. UNSATISFACTORY MATERIAL REMOVED BELOW DEPTHS INDICATED SHALL BE REPLACED WITH
SATISFACTORY MATERIAL AT NO ADDITIONAL COST TO THE GOVERNMENT. THE THICKNESS OF
CONCRETE FOOTINGS SHALL BE INCREASED IN THICKNESS TO THE BOTTOM OF THE OVER-DEPTH
EXCAVATIONS AND OVER-BREAK IN ROCK EXCAVATIONS.
8. EXCAVATION SHALL BE PERFORMED SO THAT THE AREA WILL BE CONTINUALLY AND EFFECTIVELY DEWATERED TO ELIMINATE ANY GROUND WATER IN THE EXCAVATION AS WELL AS SURFACE DRAINED
TO ELIMINATE ANY SURFACE WATER. WATER FROM ANY SOURCE SHALL NOT BE PERMITTED TO
ACCUMULATE IN CRAWL SPACE AREAS AND IN THE EXCAVATION. THE EXCAVATION SHALL BE DRAINED
BY PUMPING OR OTHER SATISFACTORY METHODS TO PREVENT SOFTENING OF THE FOUNDATION
BOTTOM, UNDERCUTTING OF FOOTINGS, OR OTHER ACTIONS DETRIMENTAL TO PROPER
CONSTRUCTION.
9. SHORING INCLUDING SHEET PILING SHALL BE FURNISHED AND INSTALLED AS NECESSARY TO
PROTECT WORKMEN, BANKS, ADJACENT PAVING, STRUCTURES, AND UTILITIES.
10. THE CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT SHALL INSPECT THE
SOIL SUBGRADE FOR ALL SLABS IMMEDIATELY PRIOR TO PLACING CONCRETE.
11. NO SLABS, FOOTINGS OR GRADE BEAMS SHALL BE PLACED ONTO OR AGAINST SUBGRADE
CONTAINING FREE WATER, FROST OR ICE. SHOULD WATER, FROST, OR ICE ENTER A FOOTING OR SLAB
EXCAVATION AFTER SUBGRADE APPROVAL, THE SUBGRADE SHALL BE RE-INSPECTED BY THE
CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT.
12. BACKFILL SHALL BE PLACED SIMULTANEOUSLY ON BOTH SIDES OF FOUNDATION WALLS.
13. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY MEASURES TO PREVENT ANY FROST OR ICE FROM PENETRATING ANY FOOTING OR SLAB SUBGRADE AFTER PLACING OF CONCRETE UNTIL SUCH
SUBGRADE IS FULLY PROTECTED BY THE PERMANENT BUILDING STRUCTURE.
14. NON-EXPANSIVE FILL MATERIALS WITHIN THE BUILDING FOOTPRINT SHALL BE COMPACTED TO AT
LEAST 95% OF LABORATORY MAXIMUM DENSITIES PER ASTM STANDARD D 1557 AND PLACED IN
CONTROLLED LIFTS NOT EXCEEDING 8 INCHES IN LOOSE THICKNESS.
15. MATERIALS SHALL BE MOISTENED OR AERATED AS NECESSARY TO PROVIDE PROPER WATER
CONTENT THAT WILL READILY FACILITATE OBTAINING THE SPECIFIED COMPACTION WITH EQUIPMENT
USED.
16. COMPACTION SHALL BE ACCOMPLISHED BY SHEEPSFOOT ROLLERS, PNEUMATIC-TIRED ROLLERS, STEEL-WHEELED ROLLERS, OR OTHER APPROVED EQUIPMENT WELL SUITED TO THE SOIL BEING
PREPARED.
17. WHEN SUBGRADE SURFACES ARE LESS THAN THE SPECIFIED DENSITY, THE SURFACE SHALL BE BROKEN UP TO A MINIMUM DEPTH OF 6 INCHES, PULVERIZED AND COMPACTED TO THE SPECIFIED
DENSITY.
18. THE EXCAVATED SURFACE SHALL BE SCARIFIED TO A DEPTH OF 6 INCHES BEFORE FILL PLACEMENT.
19. SUBGRADE PREPARATION UNDER MAT FOUNDATION SHALL CONSIST OF REMOVAL OF A MINIMUM OF
5.0 FEET OF EXISTING SOILS WITHIN THE BUILDING/STRUCTURE FOOTPRINT AND REPLACEMENT WITH
COMPACTED NON-EXPANSIVE BACKFILL, AND THAT A MINIMUM OF 2.5 FEET OF COMPACTED
NON-EXPANSIVE FILL IS PLACED IMMEDIATELY BENEATH THE MAT SLAB, WHICHEVER IS GREATER.
20. EXCAVATED AREAS BEYOND THE LIMITS OF THE BUILDING FOOTPRINT SHALL BE BACKFILLED WITH SELECT CLAY BACKFILL MATERIAL. THIS SELECT CLAY CAP SHALL BE A MINIMUM OF 2 FEET IN THICKNESS AND SHALL EXTEND FROM THE BUILDING PERIMETER TO THE LIMITS IF THE EXCAVATION AND COMPACTED TO AT LEAST 92% OF LABORATORY MAXIMUM DENSITY IN ACCORDANCE PER ASTM D 1557.
21. FILL MATERIALS SHALL BE AS FOLLOWS:
CONCRETE NOTES
1. CONCRETE WORK SHALL CONFORM WITH ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE" AND IBC "CHAPTER 19 - CONCRETE." REFER TO SHEET S-001 FOR DESIGN CODE SUMMARY TABLE
FOR APPLICABLE CODE YEAR EDITIONS.
2. ALL CONCRETE PERMANENTLY EXPOSED TO WEATHER SHALL CONTAIN AN APPROVED AIR ENTRAINING
ADMIXTURE.
3. NO CALCIUM CHLORIDE SHALL BE USED IN ANY CONCRETE.
4. CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS ACCOMPANIED WITH RECENT FIELD TEST REPORT DATA OR TRIAL BATCH LAB REPORTS FOR ALL PROPOSED CONCRETE MIXES FOR APPROVAL PRIOR TO FIRST
POUR.
5. VERTICAL WALL CONSTRUCTION JOINTS SHALL BE FORMED WITH VERTICAL BULKHEADS AND KEYWAYS. WALL REINFORCING SHALL BE CONTINUOUS THROUGH THE JOINT OR SHALL BE DOWELED WITH AN EQUIVALENT
AREA OF REINFORCEMENT.
6. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE LOCATION AND PLACEMENT OF INSERTS, EMBEDDED PLATES, MASONRY ANCHORS, REGLETS, SLEEVES, DUCTWORK, PADS AND ANCHOR RODS. THE INSERTS, EMBEDDED PLATES, ETC. SHALL NOT INTERFERE WITH CONCRETE REINFORCEMENT LOCATION. THE GENERAL CONTRACTOR SHALL VERIFY ALL OPENINGS THROUGH WALLS WITH SHOP DRAWINGS, SHOWING OPENINGS IN THE SLABS INCLUDING, BUT NOT LIMITED TO, SLEEVE SIZES AND
LOCATIONS, DUCT SIZE AND LOCATION, ETC.
7. NO OPENING SHALL BE MADE IN ANY STRUCTURAL MEMBER WITHOUT THE WRITTEN APPROVAL OF THE
CONTRACTING OFFICER.
8. CONSTRUCTION JOINTS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL. LOCATIONS SHALL BE COORDINATED WITH THE RACK LAYOUT SUCH THAT NO LONGITUDINAL CONSTRUCTION JOINTS (ALONG DIRECTION OF TRAFFIC) ARE PLACED WITHIN RACK AISLES. CONSTRUCTION JOINTS TRANSVERSE TO
THE RACK AISLES SHALL BE ALLOWED.
9. DEPRESSED SLABS SHALL MAINTAIN FULL THICKNESS UNLESS NOTED OTHERWISE.
10. BASIS OF DESIGN FOR CHEMICAL ANCHORS SHALL BE "HIT-RE 500 V3" OR "HIT-HY 200" AND EXPANSION ANCHORS SHALL BE "KWIK BOLT 3" AS MANUFACTURED BY HILTI OR EQUAL. ANY SUBSTITUTED PRODUCT MUST MEET ALL OF THE DESIGN VALUES OF HILTI AND BE APPROVED BY THE CONTRACTING OFFICER.
ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION. USE OF POST-INSTALLED ANCHORS IN LIEU OF CAST-IN-PLACE ANCHORS OR ANY OTHER VARIATION FROM THE CONTRACT DRAWINGS IS NOT PERMITTED WITHOUT PRIOR APPROVAL FROM THE CONTRACTING OFFICE.
11. PITCH CONCRETE SLABS TO FLOOR DRAINS, IF REQUIRED, WHILE MAINTAINING THE SLAB THICKNESS. SEE ARCHITECTURAL DRAWINGS FOR TYPE AND LOCATION OF ALL FLOOR FINISHES, FLOOR DEPRESSIONS, AND
CURBS.
12. ALL STRUCTURAL CONCRETE AND CONCRETE FILL SHALL BE THOROUGHLY CONSOLIDATED WITH
MECHANICAL VIBRATORS.
13. THE CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT SHALL INSPECT THE
PLACEMENT OF ALL CONCRETE, REINFORCEMENT, AND FORMWORK.
14. PROVIDE 3/4" CHAMFER ON ALL CORNERS OF EXPOSED CONCRETE, UNLESS NOTED OTHERWISE IN THE
ARCHITECT'S DRAWINGS.
15. REFERENCE SPECIFICATION: SECTION 03 30 00 - CAST-IN-PLACE CONCRETE.
16. ALL CAST-IN-PLACE CONCRETE SHALL BE OF THE TYPE I OR III AND HAVING MINIMUM COMPRESSIVE
STRENGTH AS INDICATED IN THE TABLE BELOW:
STRUCTURAL ELEMENT f'c AT 28 DAYS AGGREGATE REMARKS
FOOTINGS, EXPOSED RET WALLS 4,000 PSI 145 PCF STONE AIR ENTRAINED AS REQD. BY ACI 318, F1S0P0C1
FLAT MAT 4,500 PSI 145 PCF STONE F0S0P0C0 DURABILITY PER ACI 318,
MINIMUM TENSILE STREGTH 600 PSI
CAST IN PLACE, OTHER 4,000 PSI 145 PCF STONE F0S0P0C0 DURABILITY PER ACI 318
REINFORCEMENT NOTES
1. ALL CONCRETE REINFORCEMENT SHALL BE DETAILED, FABRICATED, LABELED, SUPPORTED, SPACED IN
FORMS, AND SECURED IN PLACE IN ACCORDANCE WITH THE PROCEDURES AND REQUIREMENTS PER ACI 318 AND ACI DETAILING MANUAL SP-66(04). REFER TO SHEET S-001 FOR DESIGN CODE SUMMARY TABLE
FOR APPLICABLE CODE YEAR EDITIONS.
2. UNLESS NOTED OTHERWISE, DEFORMED BAR REINFORCEMENT SHALL CONFORM TO ASTM SPECIFICATION
A615, GRADE 60 AND ASTM A706, GRADE 60 FOR WELDED DEFORMED BAR REINFORCEMENT.
3. HEADED SHEAR STUD ASSEMBLIES SHALL CONFORM TO ASTM A1044 WITH MINIMUM Fy = 51 KSI.
4. ALL WELDED WIRE FABRIC SHALL CONFORM TO THE STANDARDS OF ASTM A1064.
5. THE CONTRACTOR SHALL SUBMIT CHECKED SHOP DRAWINGS SHOWING REINFORCING DETAILS INCLUDING STEEL SIZES, SPACING, PLACEMENT AND SUPPORT DETAILS TO THE CONTRACTING OFFICER FOR REVIEW
PRIOR TO FABRICATION.
6. PROVIDE ALL ACCESSORIES NECESSARY TO SUPPORT REINFORCEMENT AT THE POSITIONS INDICATED.
PLASTIC COATED OR STAINLESS STEEL ACCESSORIES SHALL BE USED IN ALL EXPOSED CONCRETE WORK.
7. ALL EMBEDMENT LENGTHS AND LAPS SHALL BE AS REQUIRED BY ACI 318. UNLESS NOTED OTHERWISE, MINIMUM LAP SHALL CLASS B SPLICE PER TABLE SHOWN ON THIS SHEET.
8. UNLESS NOTED OTHERWISE ON PLANS, ALL CONCRETE FORMED SLAB OR WALL OPENINGS SHALL BE REINFORCED AT EACH CORNER WITH MINIMUM 2 NO. 5 BARS, PLACED ONE IN EACH FACE AT 45 DEGREES
AND PROJECTING MINIMUM 2'-0" BEYOND CORNER.
9. WHERE REQUIRED, DOWELS SHALL MATCH THE SIZE AND QUANTITY OF MAIN REINFORCING, UNLESS
NOTED OTHERWISE
10. THE CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT SHALL INSPECT THE
PLACEMENT OF ALL REINFORCEMENT.
11. THE CONCRETE COVER PROVIDED FOR ALL REINFORCEMENT SHALL COMPLY WITH ACI 318, LATEST
EDITION. THE FOLLOWING CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMEN, UNO:
CONDITION OF CONCRETE CASTING REINF. BAR RANGE COVER
CONCRETE CAST AGAINST AND PERMANENTLY
EXPOSED TO EARTH
#3 THRU #18 BARS 3"
CONCRETE EXPOSED TO EARTH OR WEATHER #6 THRU #18 BARS 2"
#5 BAR & SMALLER 1 1/2"
CONCRETE NOT EXPOSED TO WEATHER OR IN
CONTACT WITH GROUND
- SLABS, WALLS, JOISTS #14 & #18 BARS 1 1/2"
#11 BARS & SMALLER 3/4"
- BEAM, COLUMNS #3 THRU #18 BARS 1 1/2"
MASONRY NOTES
1. DESIGN AND CONSTRUCTION OF MSASONRY SHALL BE IN ACCORDANCE WITH TMS MSJC-13. REFER TO
SHEET S-001 FOR DESIGN CODE SUMMARY TABLE FOR APPLICABLE CODE YEAR EDITIONS.
2. MASONRY UNIT MATERIALS SHALL BE CONCRETE MASONRY UNITS: MEDIUM WEIGHT, ASTM C-90 OR ASTM
C-55 WITH AVERAGE NET AREA COMPRESSIVE STRENGTH OF MASONRY UNITS:
a.) 2,800 PSI FOR 8", 10" & 12" WIDE CMU (TYPE "S" 1,800 PSI COMPRESSIVE STRENGTH MORTAR) b.) 1,900 PSI FOR 6" WIDE AND SMALLER CMU (TYPE "N" 750 PSI COMPRESSIVE STRENGTH MORTAR)
BRICK UNITS: ASTM C 216, AVERAGE NET AREA COMPRESSIVE STRENGTH 4,150 PSI
3. MORTAR FOR ALL MASONRY SHALL CONFORM TO ASTM C270 TYPE "S" (1,800 PSI COMPRESSIVE STRENGTH) FOR EXTERIOR CMU AND TYPE "N" (750 PSI COMPRESSIVE STRENGTH) FOR BRICK & INTERIOR CMU:
a.) NET AREA COMRESSIVE STRENGTH OF MASONRY f'm = 2,000 PSI FOR WALLS WITH 8", 10" & 12" CMU b.) NET AREA COMRESSIVE STRENGTH OF MASONRY f'm = 1,500 PSI FOR ALL OTHER WALLS
4. GROUT FOR MASONRY SHALL CONFORM TO ASTM C476 AND SHALL HAVE A MINIMUM COMPRESSIVE
STRENGTH OF 3,000 PSI.
5. REINFORCEMENT BARS FOR MASONRY SHALL CONFORM TO ASTM SPECIFICATION A615, GRADE 60.
6. PROVIDE REBAR POSITIONERS AT 4'-0" O.C. IN GROUTED CELLS TO ASSURE PROPER PLACEMENT OF
REBARS.
7. BRICK VENEER SHALL BE ANCHORED TO METAL STUD BACK-UP WALL WITH PINTLE ANCHORS.
8. VERTICAL CELLS TO BE FILLED WITH GROUT, AND VERTICAL CELLS TO BE REINFORCED AND FILLED WITH GROUT, SHALL BE ALIGNED TO PROVIDE A CONTINUOUS, UNOBSTRUCTED OPENING OF THE DIMENSIONS SHOWN ON THE PLANS, AND NOT LESS THAN 2" x 3".
9. GROUT FOR FILLING REINFORCED OR NON-REINFORCED CELLS SHALL BE PLACED IN MAXIMUM FIVE FEET FOUR INCHES (5'-4") LIFTS AND CONSOLIDATED IN PLACE BY VIBRATION OR OTHER METHODS WHICH INSURE COMPLETE FILLING OF THE CELLS. ALL CELLS CONTAINING REINFORCING BARS OR ANCHOR RODS
SHALL BE FULLY GROUTED.
10. HOLLOW UNITS SHALL BE LAID WITH FULL MORTAR COVERAGE ON HORIZONTAL AND VERTICAL FACE SHELLS. WEBS SHALL ALSO BE BEDDED, WHERE THEY ARE ADJACENT TO CELLS TO BE REINFORCED OR FILLED WITH GROUT, IN THE STARTING COURSE ON FOOTINGS AND SOLID FOUNDATION WALLS, AND IN NON-REINFORCED OR GROUTED PIERS, PILASTERS AND COLUMNS. SOLID MASONRY UNITS SHALL BE LAID
WITH FULL HEAD AND BED JOINTS.
11. BEARING ENDS OF LINTELS AND BEAMS SHALL BE ON TWO MINIMUM (2) COURSES OF SOLID MASONRY OR
TWO (2) COURSES OF HOLLOW MASONRY GROUTED SOLID.
12. THE MINIMUM CLEAR DISTANCE BETWEEN PARALLEL REINFORCING BARS, EXCEPT IN COLUMNS, SHALL BE
EQUAL TO THE NOMINAL DIAMETER OF THE BAR, OR 1", WHICHEVER IS GREATER.
13. WHERE REQUIRED VERTICAL REINFORCEMENT SHALL BE LAP SPLICED AS INDICATED IN THE TABLE
LOCATED ON THIS SHEET.
14. ALL REINFORCING BARS SHALL BE COMPLETELY EMBEDDED IN GROUT AND SHALL HAVE A COVERAGE OF
MASONRY NOT LESS THAN:
a.) BARS LARGER THAN #5: 2" b.) #5 BARS AND SMALLER: 2"
15. PROVIDE ADEQUATE TEMPORARY BRACING AS REQUIRED DURING CONSTRUCTION TO WITHSTAND
LATERAL LOADS AND THE PRESSURES OF FLUID GROUT.
16. ALL WALLS SHALL HAVE HORIZONTAL JOINT REINFORCING AT 16" ON CENTER - SEE ARCHITECTURAL
DRAWINGS.
17. VERTICAL REINFORCING SHALL BE CONTINUOUS THROUGH ALL CMU LINTELS.
18. ALL BOND BEAM REINFORCING SHALL BE DISCONTINUOUS AT ALL CONTROL JOINTS.
19. ALL CMU WALLS SHALL HAVE VERTICAL CONTROL JOINTS. FOR SPACING AND LOCATION OF CONTROL
JOINTS SEE ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.
20. NO CONTROL JOINTS IN CMU WALL SHALL BE LOCATED LESS THAN 24" FROM THE FACE OF A MASONRY
OPENING.
21. THE CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT SHALL INSPECT ALL
MASONRY WORK TO CONFORM TO TMS MSJC SPECIFICATIONS "LEVEL B QUALITY ASSURANCE."
M A
R K
D E
S C
R
IP
T
IO
N D
A T
IBC 2015 SPECIAL INSPECTION REQUIREMENTS
STRUCTURAL STEEL: WELDING
STRUCTURAL STEEL: NON-DESTRUCTIVE TESTING OF WELDED JOINTS
STRUCTURAL STEEL: HIGH-STRENGTH BOLTING
STRUCTURAL STEEL: ANCHOR RODS, EMBEDS, FABRICATED STEEL FRAMES
STRUCTURAL STEEL: COMPOSITE CONSTRUCTION
COLD-FORMED STEEL FLOOR AND ROOF DECK, QUALIFICATIONS OF WELDING
SPECIAL INSPECTORS
OPEN WEB STEEL JOISTS & GIRDERS: INSTALLATION, END CONNECTIONS
BOLTED / WELDED, BRIDGING HORIZONTAL / DIAGONAL
WELDING OF REINFORCING BARS PER AWS D1.4:
WELDEABILITY OF BARS OTHER THAN A706, SINGLE PASS FILLETS < 5/16"
ALL OTHER WELDS
CONCRETE CONSTRUCTION: REINFORCING STEEL, PRE-STRESSING TENDONS,
PLACEMENT OF REINF STEEL; DESIGN MIX; POST-INSTALLED STEEL ANCHORS;
CURING TEMPERATURE & TECHNIQUES; IN-SITU CONCRETE STRENGTH;
FORMWORK
CONCRETE CONSTRUCTION: DURING SAMPLING FOR CONC STRENGTH TESTS,
PERFORM SLUMP & AIR CONTENT TESTS & DETERMINE CONC TEMP; CONC
PLACEMENT FOR PROPER APPLICATION TECHNIQUES; PRE-STRESSING FORCE
APPLICATION
MASONRY CONSTRUCTION: INSPECTED & VERIFIED PER TMS 402/ACI 530/ASCE
5 & TMS 602/ACI 530.1/ASCE 6, LEVEL B QUALITY ASSURANCE
SOILS: DESIGN BEARING CAPACITY OF MATERIALS BELOW SHALLOW FDNS;
DEPTH & PROPER MATERIAL AT BOTTOM OF EXCAVATIONS; CLASSIFICATION &
TESTING OF COMPACTED FILL; SUB-GRADE & SITE PREPARATION
SOILS: PROPER MATERIAL, DENSITY & LIFT THICKNESS DURING PLACEMENT &
COMPACTION OF COMPACTED FILL
CAST-IN-PLACE DEEP FOUNDATIONS: DRILLING OPERATIONS; LOCATION &
PLUMBNESS; SHAFT & BELL DIAMETERS; LENGTH; BEDROCK EMBEDMENT;
END-BEARING STRATA CAPACITY; GROUT & CONCRETE VOLUMES
COLD-FORMED LIGHT FRAME CONSTRUCTION: CONTINUOUS AND PERIODIC
INSPECTION AS APPLICABLE, SEE REMARK
FIRE-RESISTANT PENETRATIONS AND JOINTS
STRUCTURAL OBSERVATIONS: PROJECT DOES NOT REQUIRE STRUCTURAL
OBSERVATIONS FOR SEISMIC AND WIND RESISTANCE PER IBC UNLESS SUCH
OBSERVATION IS SPECIFICALLY REQUIRED BY AHJ.
STRUCTURAL ELEMENT CONTINUOUS PERIODIC REMARKS
- X
X
X
X
X
X
X
X
AISC 360-10
TABLES
N5.4-1,4-2,4-3
AISC 360-10
SECTION N.5.5
AISC 360-10
TABLES
N5.6-1,6-2,6-3
AISC 360-10
TABLE N5.7
AISC 360-10
TABLE N6.1
SDI QA/QC
IBC 1705.2.2
IBC TABLE
1705.2.3
IBC TABLE
1705.3
IBC TABLE
1705.3
IBC TABLE
1705.3
ACI 530-13
TABLE 3.1.2
IBC TABLE
1705.6
IBC TABLE
1705.6
IBC TABLE
1705.8
IBC SECTION
1705.11.3
IBC SECTION
1705.17
IBC SECTION
1704.6
X
1. THE ENGINEER IS DELEGATING THE DESIGN OF THE PRECAST CONCRETE SYSTEM TO THE PRECAST CONCRETE MANUFACTURER'S REPRESENTATIVE . THE PRECAST ENGINEER SHALL BE RESPONSIBLE FOR ALL PRECAST MEMBERS AND CONNECTION DESIGN FOR THE LOADS INDICATED ON THE DWGS.
2. ALL DESIGN AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI 318 (REFER TO SHEET S-001
FOR DESIGN CODE SUMMARY TABLE FOR THE APPLICABLE CODE YEAR EDITIONS), AND LATEST
EDITIONS OF THE PCI MNL-117, MNL-120 & PCI MNL-122.
3. REFER TO SPECIFICATIONS SECTION 034533 "PRECAST PRESTRESSED STRUCTURAL CONCRETE" FOR
DESIGN REQUIREMENTS FOR PRECAST MEMBERS AND ALL OTHER REQUIRED INFORMATION NOT
SPECIFIED HERE.
4. PRECAST CONCRETE SHALL BE NORMAL WEIGHT, AIR ENTRAINED, f'c=5, 000 PSI AT 28 DAYS, TOTAL AIR
CONTENT SHALL BE 6% +/- 1.5% USING PORTLAND CEMENT TYPE II OR III.
5. MILD REINFORCEMENT: AS SPECIFIED UNDER CONCRETE AND HEREIN. THE MINIMUM CONCRETE COVERPROTECTION SHALL BE PER ACI 318 EXCEPT AS REQUIRED FOR FIRE RATING NOTED ON THE
DRAWINGS.
6. PRESTRESSING TENDONS SHALL BE SEVEN-WIRE LOW RELAXATION TYPE STRAND PER ASTM A416, GRADE A, 270 KSI.
7. CONCRETE ACCESSORIES: COIL RODS TO BE HIGH STRENGTH, ELECTRO GALVANIZED ASTM B633. ALL
EXPOSED METAL CONNECTIONS SHALL BE HOT-DIP GALVANIZED.
8. BEARING STRIPS: PLANK- RANDOM ORIENTED FIBER REINFORCED OR MULTI-MONOMER PLASTIC
STRIPS.
9. CEMENT GROUT SHALL BE A MIXTURE OF NOT LESS THAN ONE PART PORTLAND CEMENT TO 2.5 PARTS FINE SAND. GROUT SHALL BE CAPABLE OF COMPLETELY FILLING JOINTS. MINIMUM 28-DAY GROUT
STRENGTH SHALL BE 5,000 PSI.
10. REFER TO ARCHITECTURAL DWGS FOR DOOR/WINDOW OPENINGS; LOCATION AND SIZE OF LOUVERS;
SURFACE FINISH; PARAPET AND COPING TYPES; LOCATION AND SIZE OF EMBEDS FOR CANOPIES;
INSULATION TYPE, THICKNESS AND R-VALUE FOR MULTI-WYTHE WALL PANELS; JOINT SIZE AND
LOCATION; CHAMFER AND REVEAL PROFILES.
11. GENERAL PRECAST CONCRETE:
a. GROUT ALL JOINTS AND KEYWAYS SOLID. PROVIDE KEYWAY REINFORCING.
b. PROVIDE WELD PLATES FOR ALL PLANKS THAT BEAR ON STEEL AND WELD TO SUPPORT.
c. HOLLOW CORE SLABS SHALL RECEIVE 2" COMPOSITE STRUCTURAL TOPPING, UNO.
d. ALL WELDS SHALL USE E70XX LOW HYDROGEN ELECTRODES, 1/4" MINIMUM.
e. HIGH STRENGTH BOLTS SHALL BE ASTM A325, HOT DIP GALVANIZED 3/4" DIA, UNO.
f. OPENINGS LESS THAN 10" ROUND SHALL BE LOCATED AND DRILLED BY THE TRADE REQUIRING
THEM AFTER ERECTION. ALL FIELD OPENINGS AND/OR CUTTING OF PRECAST MEMBERS SHALL
BE APPROVED BY THE CONTRACTING OFFICER AND PRECAST MANUFACTURER.
PRECAST CONCRETE NOTES
WALL
LOCATION
EXTERIOR
GPW - PERIMETER
NOTES:
1. MINIMIM THICKNESS BASED ON OTHER/NON-STRUCTURAL CRITERIA. PRECAST
SUBMITTAL TO INDICATE WYTHE THICKNESSES PER DELEGATED STRUCTURAL DESIGN.
2. WHERE ONLY EXTERIOR WYTHE IS INDICATED, WALL SHALL BE SOLID CONCRETE.
3. UNO, ALL INSULATED PANELS SHALL BE COMPOSITE OR PARTIALLY COMPOSITE
CONSTRUCTION DESIGNED TO RESIST THE LOADS INDICATED ON STRUC DWGS.
4. REFER TO ARCHITECTURAL DWGS FOR THE FOLLOWING REQUIREMENTS:
a.) FIRE RATING b.) INSULATION TYPE c.) WALL FINISHES
LOAD-BEARING
PRECAST CONCRETE PANEL MINIMUM WYTHE THICKNESS REQUIREMENTS
INSULATION INTERIOR
GPW - GRIDS F & G
ANNEX - PERIMETER
3 6 3
(IN) (R-value) (IN)
--7 --
6 213.5
NO
NO
YES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T
B D
S O
L
IC
IT
A
T
IO
N N
O
W G
-1 -D
-0
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T R
E E
T F
O R
T W
O R
T H
T
E X
A S
A U
R B
A N
E K
A U
R B
A N
E K
C B
O W
E
K S
H E
R L O
C K
G P
W -D
M M
S .r v t
D L A
G E
N E
R A
L P
U R
P O
S E
W A
R E
H O
U S
E
G P
W
R E
D R
IV
E
R A
R M
Y D
E P
O T
R
R A
D
T E
X A
S
S T
R U
C T
U R
A L
N
. M
IC
H
IG
A N
A V
E S
U
IT
E
C H
IC
A
G O
, I L w w w .e x p
F e d e ra l.c o m p ro j.
n o C
H I- -A
S-003
S T
R U
C T
U R
A L N
O T
E S
O
C T
READY TO ADVERTISE
STRUCTURAL STEEL NOTES
1. ALL DETAILING, FABRICATION AND ERECTION OF STRUCTURAL STEEL WORK SHALL CONFORM TO AISC
325 STEEL CONSTRUCTION MANUAL, AISC 360 SPECIFICATIONS AND AISC 303 CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS. REFER TO SHEET S-001 FOR DESIGN CODE SUMMARY TABLE FOR
APPLICABLE CODE YEAR EDITIONS.
2. STRUCTURAL STEEL WIDE FLANGE SHAPES SHALL CONFORM TO ASTM A992, UNLESS NOTED
OTHERWISE. STRUCTURAL STEEL PLATES, ANGLES, CHANNELS AND MISCELLANEOUS MATERIAL SHALL CONFORM TO ASTM A36. HOLLOW STRUCTURAL SECTIONS SHALL CONFORM TO ASTM A500, GRADE B.
STEEL PIPE SECTIONS SHALL CONFORM TO ASTM A53, GRADE B.
3. ANCHOR RODS SHALL BE ASTM F1554, GRADE 55 WITH WELDABILITY SUPPLEMENT S1 AND CARBON EQUIVALENT FORMULA PER ASTM F1554 SECTION S1.5.2.1 WITH DIAMETER AND LENGTH OF EMBEDMENT
AS INDICATED ON STRUCTURAL DRAWINGS.
4. HIGH STRENGTH BOLTING SHALL BE DONE IN ACCORDANCE WITH AISC "SPECIFICATION FOR
STRUCTURAL JOINTS USING ASTM A325 OR ASTM A490 BOLTS."
5. BOLTS, NUTS AND WASHERS SHALL CONFORM TO THE REQUIREMENTS OF ASTM A325. BOLTS SHALL BE
0.75 INCH DIA. MINIMUM UNLESS OTHERWISE INDICATED.
6. WELDING SHALL BE DONE BY CERTIFIED WELDERS AND SHALL CONFORM TO AWS D1.1 STRUCTURAL
WELDING CODE - STEEL", LATEST EDITION. ALL WELDING ELECTRODES SHALL BE E70XX.
7. THE FABRICATOR/ERECTOR SHALL SUBMIT TO THE CONTRACTING OFFICER FOR REVIEW, ENGINEERED AND CHECKED SHOP DRAWINGS SHOWING FABRICATION DETAILS, FIELD ASSEMBLY DETAILS AND
ERECTION DIAGRAMS FOR ALL STRUCTURAL STEEL.
8. UNLESS NOTED OTHERWISE, ALL CONNECTIONS SHALL BE DESIGNED AND DETAILED BY THE
FABRICATOR, USING RATIONAL ENGINEERING DESIGN AND STANDARD PRACTICE IN ACCORDANCE WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. THE TYPICAL DETAILS SHOWN ON THE DRAWINGS ARE CONCEPTUAL ONLY AND, UNLESS SPECIFICALLY NOTED, DO NOT INDICATE THE REQUIRED NUMBER
OF BOLTS OR WELD SIZES.
9. THE FABRICATOR SHALL SUBMIT CALCULATIONS FOR EACH CONNECTION TYPE AND MEMBER SIZE WITH DETAILS AND COORDINATED SHOP DRAWINGS. CALCULATIONS SHALL BE STAMPED AND SIGNED BY A
STRUCTURAL ENGINEER LICENSED IN THE STATE OF TEXAS.
10. STEEL BEAM AND GIRDER CONNECTIONS SHALL BE DESIGNED USING THE LOAD AND RESISTANCE FACTOR DESIGN METHOD FOR FORCES INDICATED ON THE DRAWINGS. MINIMUM CONNECTION SHEAR FORCE IS 10 KIPS. REFERENCE AISC STEEL CONSTRUCTION MANUAL, FOURTEENTH EDITION TABLE 3 - 6
FOR UNIFORM LOAD (LRFD).
11. UNLESS NOTED OTHERWISE, CONNECTIONS SHALL BE EITHER AISC DOUBLE ANGLE OR SINGLE PLATE SIMPLE SHEAR CONNECTIONS PROVIDING ROTATIONAL DUCTILITY AS DEFINED BY AISC. ALL BOLTED COMPONENTS SHALL UTILIZE MINIMUM 2 BOLTS IN BEARING. CONNECTIONS SHALL EXTEND TO AT LEAST
ONE HALF OF THE BEAM DEPTH. WELDED CONNECTION MAY BE USED WITH THE SAME MINIMUM
EQUIVALENT CONNECTION CAPACITY AND DUCTILITY.
12. FIELD CONNECTIONS, EXCEPT WHERE SHOWN TO BE WELDED, SHALL BE BOLTED.
13. BEAMS AND GIRDERS SHALL BE FABRICATED WITH THE NATURAL CAMBER UP. PROVIDE CAMBERS AS
INDICATED ON THE DRAWINGS.
14. ALL STEEL SURFACES WHICH WILL BE PERMANENTLY EXPOSED TO ELEMENTS SHALL BE HOT-DIPPED GALVANIZED. DAMAGED AREAS AND/OR FIELD-WELDED AREAS SHALL BE TOUCHED UP WITH ZINC RICH
(65% TO 69% METALLIC ZINC BY WEIGHT) PAINT PER ASTM A-780.
15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF ALL ERECTION PROCEDURES AND
SEQUENCES WITH RELATION TO TEMPERATURE DIFFERENTIALS, ESPECIALLY WITH RESPECT TO
STRUCTURAL STEEL FRAMING INTO CONCRETE WALLS, BEAMS OR COLUMNS.
16. THERE SHALL BE NO FIELD CUTTING OF STRUCTURAL STEEL MEMBERS FOR THE WORK OF OTHER
TRADES WITHOUT THE PRIOR WRITTEN APPROVAL OF THE CONTRACTING OFFICER.
17. ERECT AND MAINTAIN TEMPORARY BRACING TO ENSURE THE ALIGNMENT AND STABILITY OF THE STRUCTURE DURING ERECTION UNTIL PERMANENT CONNECTIONS HAVE BEEN COMPLETED. LATERAL SYSTEM ELEMENTS FOR THIS PROJECT CONSIST OF (BUT ARE NOT NECESSARILY LIMITED TO) THE
FOLLOWING: STEEL BRACING, FLOOR & ROOF DIAPHRAGMS.
18. PROVIDE 0.25 INCH END PLATES SEAL WELDED TO ENDS OF ALL HSS MEMBERS U.N.O.
19. SHOP AND FIELD TESTING AND INSPECTION OF STRUCTURAL STEEL FABRICATION AND ERECTION SHALL BE PERFORMED BY THE CONTRACTOR'S TESTING LABORATORY APPROVED BY THE GOVERNMENT, AS
OUTLINED IN THE SPECIFICATIONS.
METAL DECK NOTES
1. METAL DECK SHALL BE FABRICATED, DETAILED, AND ERECTED IN ACCORDANCE WITH THE "STEEL DECK
INSTITUTE (SDI) SPECIFICATIONS" REFER TO SHEET S-001 FOR DESIGN CODE SUMMARY TABLE FOR
APPLICABLE CODE YEAR EDITIONS.
2. METAL DECK SECTION PROPERTIES SHALL BE COMPUTED IN ACCORDANCE WITH AISI "SPECIFICATION
FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS". METAL DECKING SHALL BE
FABRICATED FROM STEEL TYPE ASTM A653, STRUCTURAL QUALITY, HAVING A MINIMUM YIELD STRENGTH
OF 33 KSI.
3. GALVANIZING SHALL CONFORM TO ASTM A653 WITH MINIMUM COATING CLASS OF G60.
4. PROVIDE ENGINEERED AND CHECKED SHOP DRAWINGS INDICATING LOCATION, GAGE AND SIZE OF EACH PIECE OF DECKING AND RELATED DECKING ACCESSORY. THE SHOP DRAWINGS SHALL CLEARLY SHOW WELDING DETAILS TO STRUCTURAL FRAMING, SIDE LAP CONNECTION DETAILS, DECK OPENINGS, EDGE
CLOSURES, AND ANY REQUIRED SUPPLEMENTARY DECK REINFORCING.
5. STEEL ROOF DECK SHALL BE 3" DEEP WITH MINIMUM 20 GAGE, TYPE AS INDICATED ON PLANS.
6. THE METAL DECK SHALL BE DESIGNED TO BE CONTINUOUS OVER THREE (3) SPANS IN THE DIRECTION INDICATED. SINGLE AND DOUBLE SPANS, IF REQUIRED, SHALL SATISFY LOAD AND DEFLECTION
REQUIREMENTS.
7. ALL DECKING SHALL BE FASTENED TO STRUCTURAL SUPPORTS AS INDICATED ON THESE DRAWINGS.
8. PROVIDE CONTINUOUS SHEET METAL CLOSURES AT SLAB OPENINGS AND SLAB EDGES AND
CONTINUOUS DECK CLOSURE AT DECK ENDS. MINIMUM CLOSURE GAGE SHALL COMPLY WITH STEEL
DECK INSTITUTE RECOMMENDATIONS FOR THE SLAB DEPTH AND OVERHANG DISTANCE.
9. PROVIDE, AS REQUIRED, RIDGE AND VALLEY PLATES, COLUMN CLOSURES, CANT STRIPS, SUMP PLATES AT PIPING PENETRATIONS AND RECESSED SUMP PANS AT ROOF DRAINS. PROVIDE SUPPLEMENTAL
FRAMING AT OPENINGS AS REQUIRED FOR SUPPORT OF THE METAL DECK. OPENINGS SHALL BE
COORDINATED WITH ARCHITECTURAL AND MECHANICAL DRAWINGS.
10. ANY METAL DECK OPENING THAT IS 12-INCH DIAMETER OR LARGER OR ANY GROUP OF OPENINGS THAT PENETRATE MORE THAN ONE METAL DECK RIB SHALL BE FRAMED WITH SUPPLEMENTAL STEEL FRAMING
AS INDICATED ON THE DRAWINGS.
11. ALL HANGERS FOR HIGH PRESSURE DUCTWORK, CONDUIT RACKS, PIPES LARGER THAN 4" DIAMETER, ETC. SHALL BE HUNG DIRECTLY FROM STRUCTURAL STEEL FRAMING.
12. A 50 LB. MAXIMUM CONCENTRATED LOAD MAY BE HUNG DIRECTLY FROM THE COMPOSITE DECK PROVIDED NO OTHER DECK SUPPORTED HANGER IS WITHIN A 30" RADIUS. THIS NOTE SUPERSEDES ANY SIMILAR NOTES ON THE MEP/FP DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING AND
INSTALLING AN APPROPRIATE ANCHORING SYSTEM.
13. NO LOADS SHALL BE PERMITTED TO BE HUNG DIRECTLY FROM METAL ROOF DECK.
14. THE ASSUMED CONSTRUCTION LIVE LOAD IS 20 PSF. CONTRACTOR SHALL TAKE ALL MEASURES NECESSARY TO ENSURE TEMPORARY CONSTRUCTION LOADINGS DO NOT EXCEED ALLOWABLE LOADING
FOR THE TYPE AND GAGE OF DECK.
STEEL JOISTS & JOIST GIRDERS NOTES
1. JOIST AND JOIST GIRDER MATERIALS, DESIGN & MANUFACTURE, HANDLING AND ERECTION SHALL BE PER
SJI STANDARD SPECIFICATIONS & SJI CODE OF STANDARD PRACTICE, LATEST EDITION.
2. MANUFACTURER SHALL BE A MEMBER OF THE STEEL JOIST INSTITUTE (SJI) FULLY CERTIFIED TO
ENGINEER AND MANUFACTURE K, LH, AND DLH-SERIES JOISTS AND JOIST GIRDERS.
3. PROVIDE ONE SHOP COAT OF PRIMER (TT-P-636) EXCEPT ITEMS TO RECEIVE SPRAY FIREPROOFING.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH.
4. REFER TO DETAILS FOR SPECIAL TREATMENT OF SUPPORTING CONCENTRATED LOADS.
5. JOISTS SHALL BE DESIGNED TO RESIST A NET UPLIFT AS SHOWN ON LOADING DIAGRAMS.
6. SUBMIT TO THE CONTRACTING OFFICER FOR REVIEW SHOP DRAWINGS OF JOISTS & JOIST GIRDERS FOR
FABRICATION AND ERECTION PRIOR TO FABRICATING JOISTS.
7. ALL JOISTS SHALL BE DESIGNED FOR A SINGLE CONCENTRATED TRAVELING PROVISIONAL LOAD OF 300 POUNDS ALONG THE TOP CHORD AND 100 POUNDS (300 LBS LBS FOR ANNEX) ALONG THE BOTTOM
CHORD APPLIED BETWEEN PANEL POINTS
8. VERTICAL SHEARS TO BE USED IN DESIGN OF WEB MEMBERS SHALL BE DETERMINED FROM FULL UNIFORM LOADING, BUT SUCH VERTICAL SHEARS SHALL BE NOT LESS THAN 25% OF END REACTION.
INTERIOR VERTICAL WEB MEMBERS USED IN MODIFIED WARREN TYPE WEB SYSTEMS SHALL BE
DESIGNED TO RESIST GRAVITY LOADS SUPPORTED BY MEMBER PLUS AN ADDITIONAL AXIAL LOAD OF 0.5% OF THE TOP CHORD AXIAL FORCE FOR K, LH, AND DLH-SERIES JOISTS. FOR JOIST GIRDERS, WEB SYSTEMS THAT DO NOT SUPPORT DIRECT LOADS THROUGH STEEL JOISTS SHALL BE DESIGNED TO RESIST AN AXIAL LOAD OF 2% OF TOP CHORD AXIAL FORCE AND TENSION MEMBERS SHALL BE DESIGNED
TO RESIST AT LEAST 25% OF THEIR AXIAL FORCE IN COMPRESSION.
9. JOIST SEATS SHALL HAVE THE CAPACITY TO RESIST A LATERAL LOAD APPLIED TO THE TOP CHORD, PERPENDICULAR TO THE SPAN (ROLLOVER). PROVIDE A MINIMUM ROLLOVER FORCE OF 2,000 POUNDS FOR SEATS UP TO 3 1/2 INCHES DEEP AND 1,200 POUNDS FOR SEAT OVER 3 1/2 INCHES DEEP
10. PROVIDE JOISTS CAPABLE OF WITHSTANDING DESIGN LOADS WITH DEFLECTIONS NO GREATER THAN L/240 FOR LIVE LOAD AND L/180 FOR DEAD + LIVE LOAD OF THE SPAN. REFER TO JOIST LOADING
SCHEDULES FOR ADDITIONAL REQUIREMENTS, WHERE APPLICABLE.
11. REFER TO GENERAL NOTES ON SHEET S-001 FOR ADDITIONAL COORDINATION REQUIREMENTS WITH
OTHER TRADES.
12. SIZES OF JOIST & JOIST GIRDERS INDICATED ON THE DRAWINGS SHALL BE MINIMUM REQUIRED. ANY
CHANGES SHALL BE MADE AT NO ADDITIONAL COST TO THE GOVERNMENT.
13. REFER TO STEEL JOIST FRAMING SPECIFICATION 05 21 00 FOR REQUIRED SUBMITTALS AND ADDITIONAL
REQUIREMENTS.
STRUCTURAL SHEET INDEX
No. SHEET NAME
S-133 ROOF FRAMING PLAN - AREA SE-B
S-134 ROOF FRAMING PLAN - AREA SE-C
S-135 ROOF FRAMING PLAN - AREA SE-D
S-200 SHEAR WALL ELEVATIONS
S-301 MAT FOUNDATION SECTIONS
S-302 MISCELLANEOUS FOUNDATION SECTIONS
S-303 INTERIOR SECTIONS
S-501 ROOF FRAMING DETAILS
S-502 ROOF FRAMING DETAILS
S-503 ROOF FRAMING DETAILS
S-504 PRECAST DETAILS
S-505 CMU DETAILS
S-506 CONCRETE DETAILS
S-601 COLUMN SCHEDULE
STRUCTURAL SHEET INDEX
No. SHEET NAME
S-001 STRUCTURAL NOTES
S-002 STRUCTURAL NOTES
S-003 STRUCTURAL NOTES
S-101 OVERALL MAT FOUNDATION PLAN
S-102 FOUNDATION PLAN - AREA NW-A
S-103 FOUNDATION PLAN - AREA NW-B
S-104 FOUNDATION PLAN - AREA NW-C
S-105 FOUNDATION PLAN - AREA NW-D
S-106 FOUNDATION PLAN - AREA NE-A
S-107 FOUNDATION PLAN - AREA NE-B
S-108 FOUNDATION PLAN - AREA NE-C
S-109 FOUNDATION PLAN - AREA NE-D
S-110 FOUNDATION PLAN - AREA SW-A
S-111 FOUNDATION PLAN - AREA SW-B
S-112 FOUNDATION PLAN - AREA SW-C
S-113 FOUNDATION PLAN - AREA SW-D
S-114 FOUNDATION PLAN - AREA SE-A
S-115 FOUNDATION PLAN - AREA SE-B
S-116 FOUNDATION PLAN - AREA SE-C
S-117 FOUNDATION PLAN - AREA SE-D
S-118 FOUNDATION & ROOF PLAN - ANNEX
S-119 ROOF FRAMING PLAN - OVERALL
S-120 ROOF FRAMING PLAN - AREA NW-A
S-121 ROOF FRAMING PLAN - AREA NW-B
S-122 ROOF FRAMING PLAN - AREA NW-C
S-123 ROOF FRAMING PLAN - AREA NW-D
S-124 ROOF FRAMING PLAN - AREA NE-A
S-125 ROOF FRAMING PLAN - AREA NE-B
S-126 ROOF FRAMING PLAN - AREA NE-C
S-127 ROOF FRAMING PLAN - AREA NE-D
S-128 ROOF FRAMING PLAN - AREA SW-A
S-129 ROOF FRAMING PLAN - AREA SW-B
S-130 ROOF FRAMING PLAN - AREA SW-C
S-131 ROOF FRAMING PLAN - AREA SW-D
S-132 ROOF FRAMING PLAN - AREA SE-A
M A
R K
D E
S C
R
IP
T
IO
N D
A T
A
A
B
B
C
C
D
D
E
E
F
F
M
M
L
L
K
K
J
J
H
H
G
G
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
10 10
11 11
12 12
13 13
14 14
52'-3" 52'-3" 52'-3" 52'-3" 52'-3" 52'-3" 52'-3" 52'-3" 52'-3" 52'-3"
525'-4"
2'-10"
K.6 L.7
0.2
/2
54'-3"
S-301
_____________________2 S-301
S-301
S-301
S-301
S-302
S-302
S-302
STAIR FTG
TYP
RETAINING WALL
FOOTING
RAMP FTG
4 THUS
S-301
4 THUS
S-301
S-301
S-302
SIM
S-302
SIM
S-302
SIM
S-301
S-302
SIM
S-302
SIM
S-301
BLDG
AREA
SPECIFIED OVERALL
GPW
ANNEX
NOTES:
1. REFER TO LATEST ACI 302.1R, GUIDE FOR CONCRETE FLOOR
AND SLAB CONSTRUCTION.
2. REFER TO DIVISION 03 SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
3. REFER TO ARCHITECTURAL DRAWINGS FOR FLOOR FINISHES.
FF LL
MINIMUM LOCAL
FF LL
ACI 302.1R FLOOR
CLASSIFICATION
35 25 21 15 5 (FLAT)
CONCRETE SURFACE
FINAL FINISHING
HARD STEEL TROWEL
20 15 12 9 2 (CONVENTIONAL) LIGHT STEEL TROWEL
FLOOR FLATNESS (FF) AND FLOOR LEVELNESS (FL) REQUIREMENTS
TRUE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T
B D
S O
L
IC
IT
A
T
IO
N N
O
W G
-1 -D
-0
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
GPW - KEY PLAN
NW NE
SW SE
A B
C D
A B
C D
A B
C D
A B
C D
REFER TO CIVIL DRAWINGS FOR SITE PLAN
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T R
E E
T F
O R
T W
O R
T H
T
E X
A S
A U
R B
A N
E K
A U
R B
A N
E K
C B
O W
E
K S
H E
R L O
C K
G P
W -D
M M
S .r v t
D L A
G E
N E
R A
L P
U R
P O
S E
W A
R E
H O
U S
E
G P
W
R E
D R
IV
E
R A
R M
Y D
E P
O T
R
R A
D
T E
X A
S
S T
R U
C T
U R
A L
N
. M
IC
H
IG
A N
A V
E S
U
IT
E
C H
IC
A
G O
, I L w w w .e x p
F e d e ra l.c o m p ro j.
n o C
H I- -A
ANNEX
S-101
O V
E R
A L L M
A T
F O
U N
D A
T
IO
N P
L A
N
O
C T
READY TO ADVERTISE
1/32" = 1'-0"S-101
1 OVERALL FOUNDATION PLAN - FLAT MAT
M A
R K
D E
S C
R
IP
T
IO
N D
A T
A B C D
52'-3" 52'-3" 52'-3"
M
A T
C H
L
IN
E
M A
T C
H L
IN
E
S
-1
-- MATCHLINE -- -- MATCHLINE --S-104
S-301
S-301
FOOTING FOR STAIR
& LANDING, COORD w/
ARCH DWGS
S-302
SIM
S-302
SIM
S-301
S-301
S-302
_____________________ FOOTING FOR
RETAINING WALL
24" MAT
#7@12" T&B
T
B
7'-1"COORD w/ ARCH DWGS
/4
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x9x5/16
H S S9x
9x 1/
H S S9x
9x 1/
H S S9x
9x 1/
H S S9x
9x 1/
S-506
TYP
1. FOR COLUMN SCHEDULE, SEE SHEET S-601.
2. FOR FOUNDATION SECTIONS, SEE SHEETS S-301 AND
S-302.
3. FOR STAIRS,RAMPS AND LANDINGS, SEE ARCH FOR
DIMENSIONS, SEE , FOR TYPICAL
SECTIONS.
4. FOR CONCRETE FLOOR FINISH - SEE TABLE ON S-101
5. FOR OTHER NOTES, SEE SHEETS S-101 AND S-001
THROUGH S-003.
SHEET NOTES:
/1 S-302 /2 S-302
TRUE
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I 'D
F
IL
E
N A
M E
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
T
B D
S O
L
IC
IT
A
T
IO
N N
O
W G
-1 -D
-0
F
IL
E N
U M
B E
R
1 2 3 4 5
D
C
B
A
GPW - KEY PLAN
NW NE
SW SE
A B
C D
A B
C D
A B
C D
A B
C D
REFER TO CIVIL DRAWINGS FOR SITE PLAN
F O
R T
W O
R T
H D
IS
T
R
IC
T T
A Y
L O
R S
T R
E E
T F
O R
T W
O R
T H
T
E X
A S
A U
R B
A N
E K
A U
R B
A N
E K
C B
O W
E
K S
H E
R L O
C K
G P
W -D
M M
S .r v t
D L A
G E
N E
R A
L P
U R
P O
S E
W A
R E
H O
U S
E
G P
W
R E
D R
IV
E
R A
R M
Y D
E P
O T
R
R A
D
T E
X A
S
S T
R U
C T
U R
A L
N
. M
IC
H
IG
A N
A V
E S
U
IT
E
C H
IC
A
G O
, I L w w w .e x p
F e d e ra l.c o m p ro j.
n o C
H I- -A
ANNEX
S-102
F O
U N
D A
T I O
N P
L A
N
A R
E A
N W
-A
O
C T
READY TO ADVERTISE
1/8" = 1'-0"S-102
1 FOUNDATION PLAN - NW-A
SCALE:
0 8' 16'
1/8" = 1' - 0"
8' 16'
M A
R K
D E
S C
R
IP
T
IO
N D
A T
D E F G
52'-3" 52'-3" 2'-10"
M
A T
C H
L
IN
E
M A
T C
H L
IN
E
S
-1
M
A T
C H
L
IN
E
M A
T C
H L
IN
E
S
-1
-- MATCHLINE -- -- MATCHLINE --S-105
S-301
S-301 _____________________ 2
S-301
FOOTING FOR
STAIR & LANDING,
COORD w/ ARCH DWGS
S-301
S-301
_____________________ 4 S-301
S-302
SIM
S-302
SIM
S-302
SIM
S-302
SIM
FOOTING FOR
RETAINING
WALL
S-302
24" MAT
#7@12" T&B
T
B
H S S9x9x5/16
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 5/
H S S9x
9x 1/
H S S9x
9x 1/
H S S9x
9x 1/
H S S9x
9x 1/
H S S9x
9x 1/
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.