MATOC PROTOTYPICAL PROJECT
NOT FOR CONSTUCTION
Sy m
D es cr ip
D at e
B y
/0 1/
IS
SU
ED
F O
R
CO
N
ST
RU
CT
IO
N
/1
2/
G W
M
OVERHANG DESIGN LOADING
DF Douglas-Fir
DIAG diagonal DIA (M) diameter
DIM dimension (s)
DL dead load DN down DWG drawing
(E) existing EA each EJ expansion joint ELEC electric(al) ELEV elevation ENCL enclose(d),(ure) ENGR engineer EQ equal EQUIP equipment EQUIV equivalent
DEMO demolish, demolition
DIST distance FDN foundation
FIN finish(ed)
FG finish grade FOC face of concrete
ETC et cetera EW each way EXIST existing EXP expand, expansion EXT exterior
FF finish(ed) floor
FJ floor joist (s)
STANDARD
ABBREVIATIONS
T&G tongue and groove
TOB top of beam
T&B top and bottom
TEMP temporary, tempered THRU through
TOG top of grade TOP top of plate TOS top of slab TOW top of wall TYP typical
FOS face of studs
FT foot, feet FTG footing
RDWD redwood REBAR reinforcing bar (s) RECT rectangular REF reference REINF reinforce (d), (ing), (ment) REQD required REV revision (s), revised
PLY plywood PREFAB prefabricated (ion) PRELIM preliminary PROJ project PROP property PSF pounds per square foot PSI pounds per square inch PT pressure treated, point
GYP gypsum HD holdown
HORIZ horizontal HT height
JST joist
QTY quantity
< angle @ at delta # number / pound / per +/- plus or minus
W width, wide, water W/ with WIN window W/O without WP waterproof (ing) WT weight WWF welded wire fabric
YD yard
VENT ventilate (ion), (or) VERT vertical
SUBFL subfloor
STD(S) standard(s) STL steel
UCBC Uniform Code for Building Conservation
UNO unless noted otherwise
GA gage, gauge GALV galvanized GC general contractor GEN general
GLB glued laminated beam
VOL volume HVAC Heating/Ventilation/A.C.
IBC International Building Code
STRUCT structural, structure
SIM similar
SPEC(S) specification(s)
FOUND foundation
GI galvanized iron
PLT plate, plot
SW shearwall
VIF verify in field
RJ roof joist (s)
RR roof rafter (s) RM room
SE structural engineer
ICC International Code Council
USACE US Army Corps of Engineers
UBC Uniform Building Code
EST estimate(d) DEG degree
ADJ adjacent, adjustable APA American Plywood Association ALT alternate APPROX approximate ARCH architect (ural)
AVG average
ASTM American Society of Testing & Materials
ASD allowable stress design
AB anchor bolt
BOT bottom
BTWN between
BLDG building BLK(G) block (ing) BM beam BN boundary nailing
ACE Army Corps of Engineers
BP Bid Package, baseplate
COMBO combination CONC concrete CONST construction CONT continuous, continue
CU cubic d penny (re: nail size)
DBL double
CJ control joint, ceiling joist (s)
CLG ceiling CLR clear(ance)
CMU concrete masonry unit COL column
CBC California Building Code
CM centimeter(s)
CANT cantilever (ed), canted
CL center line CJP complete joint penetration
CA ARNG California Army National Guard
COR Contracting Officer's Representative
ATR all thread rod
OC on center (s) OD outside diameter OMIT not part of const. docs.
OSB oriented strand board OT overturning
PEN penetrate (ion) PERF perforate (d), (tion) PERIM perimeter PERP perpendicular PL plate, property line PLF pounds per linear foot
LAM laminate(d),(tion) LB(S) pound(s) LG large LF linear foot LL live load LT (G) light (ing) LTWT lightweight
NEG negative NO number NOM nominal NTS not to scale
MAX maximum MB machine bolt MECH mechanic (al) MEP mech., elec., plumbing
MEZZ mezzanine MIN minimum, minute (s)
MM millimeter (s)
PCF pounds per cubic foot
MISC miscellaneous
M/E/P mech., elec., plumbing
YCP Youth Challenge Program
ID inside diameter IN inch(es) INCL include (d), (s), (ing)
INT interior INV invert (ed)
ICBO International Conference of Bldg. Officials
INSP inspect (ion), (or)
JFTB Joint Forces Training Base
B-25 Building 25
NIC not in contract
(N) new N north N/A not applicable
KSI kips per square inch
K kip [1000 pounds] KLF kips per linear foot KSF kips per square foot
HDR header
Number of Stories 2 Max. Height (abv.grade) 24 ft Roof DL/LL (psf) *** 19/20
GENERAL PARAMETERS
Construction Type Type V 2010 CBC / 2009 IBCBuilding Code
S-1
S
TR
U C
TU
R A L
N O
TE
S
GENERAL NOTES
STRUCTURAL DESIGN PARAMETERS
WIND DESIGN BASIS
Basic Wind Speed 85 mph Exposure C Importance Factor 1.00 Velocity Wind Pressure at Mean Roof Height
14.6 psf
SEISMIC DESIGN BASIS
Seismic Importance Factor, I 1.00* Site Class D Spectral Response Accelerations SS = 1.470
S1 = 0.532 Spectral Response Coefficients
D
SDS = 0.980
SD1 = 0.532
Seismic Design Category
BUILDING 55 RENOVATIONS
Design is not based on this being an "Essential Services" or "Mission Essential" facility.
Light framed walls sheathed with all other materials; See ASCE 7-05 Table 12.2-1
REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS,
NOTES AND INFORMATION. The following is a partial list of specification sections especially required by the work indicated in these structural plans (or structural "drawings"), provided for convenience, however also refer to all other sections of the Specifications.
SPECIFICATIONS
1. Joist to sill or girder, toenail
CONNECTION
3-8d
NAILING1,12
2. Bridging to joist, toenail each end 2-8d
3. 1" x 6" subfloor or less to each joist, face nail 2-8d
4. Wider than 1" x 6" subfloor to each joist, face nail 3-8d
5. 2" subfloor to joist or girder, blind and face nail 2-16d
6. Sole plate to joist or blocking, typical face nail Sole plate to joist or blocking, at braced wall panels
16d at 16" o.c.
3-16d per 16"
7. Top plate to stud, end nail 2-16d
8. Stud to sole plate 4-8d, toenail or 2-16d, end nail
9. Double studs, face nail 16d at 24" o.c.
10. Doubled top plates, typical face nail (UNO) Doubled top plates, lap splice (UNO)
16d at 16" o.c.
8-16d
11. Blocking between joists or rafters to top plate, toenail 3-8d
12. Rim joist to top plate, toenail 8d at 6" o.c.
13. Top plates, laps and intersections, face nail 2-16d
14. Continuous header, two pieces 16d at 16" o.c. along each edge
15. Ceiling joists to plate, toenail 3-8d
16. Continuous header to stud, toenail 4-8d
17. Ceiling joists, laps over partitions, face nail 3-16d
18. Ceiling joists to parallel rafters, face nail 3-16d
19. Rafter to plate, toenail 3-8d
20.
2010 CBC (2009 IBC) TABLE 2304.9.1 -- NAILING SCHEDULE [modified]
21. 1" x 8" sheathing or less to each bearing, face nail 2-8d
22. Wider than 1" x 8" sheathing to each bearing, face nail 3-8d
23. Built-up corner studs 16d @ 24" o.c.
24. Built-up girder and beams 20d at 32" o.c. at top and bottom and staggered 2-20d at ends and at each splice
25. 2" planks 2-16d at each bearing
26. Wood structural panels and particleboard (except where noted otherwise):
Subfloor and wall sheathing (to framing):
1/2" and less 19/32" to 3/4" 7/8" to 1" 1 1/8" to 1 1/4" Combination subfloor-underlayment (to framing):
3/4" and less 7/8" to 1" 1 1/8" to 1 1/4"
6d 8d or 6d
8d 10d or 8d
6d 8d
10d or 8d
27. Panel siding (to framing):
1/2" or less 5/8"
6d 8d
28. Fiberboard sheathing:
1/2"
25/32"
No. 11 ga.
6d
No. 16 ga.
No. 11 ga.
6d No. 16 ga.
29. Interior paneling 1/4" 3/8"
4d 6d
Common or galvanized box nails may be used except where otherwise stated.
Nails spaced at 6 inches on center at edges, 12 inches at intermediate suports except 6 inches at all supports where spans are 48 inches or more. For nailing of wood structural panel and particleboard diaphragms and shearwalls, refer to Sections 2315.3.3 and 2315.4. Nails for wall sheathing may be common or galv. box.
Common or deformed shank.
Common.
Deformed shank.
Corrosion-resistant siding or casing nails conforming to the requirements of Section 2304.3.
Fasteners spaced 3 inches on center at exterior edges and 6 inches on center at intermediate supports.
Corrosion-resistant roofing nails with 7/16" diameter head and 1 1/2" length for 1/2" sheathing and 1 3/4" length for 25/32" sheathing conforming to the requirements of Section 2304.3.
Corrosion-resistant staples with nominal 7/16" crown and 1 1/8" length for 1/2" sheathing and 1 1/2" length for 25/32" sheathing conforming to the requirements of Section 2304.3.
Panel supports at 16" (20 inches if strength axis in the long direction of the panel, unless otherwise marked).
Casing or finish nails spaced 6" on panel edges, 12" at intermediate supports.
Panel supports at 24". Casing or finish nails spaced 6" on panel edges, 12" at intermediate supports.
Panel supports11
Refer to the plans and specs. for typical attachment/achorage/nailing. Use this nailing if not specified elsewhere.12
1" brace to each stud and plate, face nail 2-8d
TYPICAL NAILING SCHEDULE STRUCTURAL OBSERVATION NOTES
The Structural Engineer, or another Engineer or Architect designated by the Structural Engineer, will perform periodic Structural Observations of construction in accordance with CBC Section 1702.1 [For BSC], designated as the "Structural Observer."
The Owner or Owner's representative and the Contractor shall coordinate a pre-construction meeting between the Structural Engineer, Structural Observer (if different than the Structural Engineer), Contractor, affected subcontractor(s) and inspector(s), to identify major structural elements and to review scheduling of the required observations. Notes from the meeting shall be included in the Structural Observation Report submitted to the Contracting Officer's Representative.
Observed deficiencies shall be reported in writing to the Owner or Owner's representative, inspector(s), contractor and the Contracting Officer's Representative.
The Structural Observer shall submit to the building official a written statement at significant construction stages stating that the site visits have been made and identifying any reported deficiencies which, to the best of the Structural Observer's knowledge, have not been resolved. A final report by the Structural Observer which states that all observed deficiencies have been resolved is required before acceptance of the work by the Owner or Owner's representative and the Contracting Officer's Representative.
"Structural Observation" means the visual observation of the structural system, for general conformance to the approved plans and specifications. Structural observation does not include or waive the responsibility for the inspections required by the code.
Additionally, Structural observation does not waive the responsibility of the contractor to conform to all the requirements of the approved plans and specifications.
The Contractor shall coordinate the scheduling of site visits to be made by the Structural Observer. Requests for structural observations should be made no less than two business days prior to the desired time, preferably one week prior. The Structual Observer shall make a good faith effort to accommodate the Contractor's request, however consideration must be given for office scheduling. Typical Structural Observation Reports shall be submitted one to seven days following structural observations, however if significant corrections or supplemental details or drawings are required, then report submittal may be delayed.
Structural Observation shall consist of site visits at various stages of construction.
Depending upon sequencing of the construction throughout the project, more than one structural obseration may be required for each 'stage' in order to adequately observe the work throughout the project. Stages of construction requiring structural observation, at a minimum, are as follows (but not necessarily in this order):
Structural Component Framing:
Observe framing members (e.g. eave rafters and blocking) and connections, prior to covering.
Lateral System Framing:
Observe framing, blocking, connections, sheathing and nailing, prior to covering.
Completion of the Structural System:
Observe completion of the structural system, after all deficiencies have been corrected, prior to covering.
1.
2.
3.
THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE ON THE PLANS:
No deviations are allowed from the structural details without the written approval of the Structural Engineer. Approval by Contracting Officer's Representative, Building Inpsector, Special Inspector, or any other party does not constitute authority to deviate from plans or specifications. All plan changes or addenda are subject to approval of the Contracting Officer's Representative. The processing of changes, assembly of permit documents, and acquisition of permits is the responsibility of the contractor.
3. Construction and materials shall comply with and be installed in accordance with the requirements of all legally constituted public authorities having jurisdiction, including all county and local ordinances, the State Industrial Accident Commission, and OSHA. Receive all required approvals prior to commencement of construction.
4. The contractor shall be responsible for all shoring and providing bracing during construction and/or erection to support all loads to which the structure may be subjected.
5. The Structural Engineer (Taylor & Syfan Consulting Engineers, Inc. (also "Taylor & Syfan")) will not be responsible for and will not have control or charge of construction means, methods, techniques, sequences or procedures, or for safety precautions and programs in connection with the construction delineated by these plans. It should be understood that the contractor or his/her agent(s) shall supervise and direct all work and shall be solely and completely responsible for all construction means, methods, techniques, sequences, procedures and conditions on the job site, including safety of all persons and property during the entire period of construction. Periodic observations by the Structural Engineer or representatives thereof are not intended to include verfication of conditions or review of the adequacy of the contractor's safety measures on or near the construction site. Shoring shall be per OSHA and the California Code of Regulations; design and inspection of shoring is by others.
6. Substitutions of specified products (such as Simpson Strong-Tie) for equivalent products are not recommended. Substitutions shall be considered, provided that the contractor follows these steps prior to any substitutions being made: (a) Contractor shall provide Taylor & Syfan with satisfactory evidence of product equivalence; (b) If satisfactory, Taylor & Syfan shall revise plans and reprint at the contractors expense; and (c) Contractor shall resubmit plans to the Contracting Officer's Representative for approval.
7. See the notes and specifications of the Architect, Mechanical Engineer, Electrical Engineer and Civil Engineer for additional requirements. Conform to recommendations of the Soils/Geotechnical Report.
9.
14.
13. Live Loads Posted: per CBC1607.3.5, the live loads for which each floor or portion thereof of a commercial or industrial building is or has been designed shall have such design live loads conspicuously posted by the owner in that part of each story in which they apply, using durable metal signs, and it shall be unlawful to remove or deface such notices. The occupant of the buidling shall be responsible for keeping the actual load below the allowable limits. The contractor shall inform the owner of the requirements and post the live loads under the owner's direction, unless instructed otherwise by the owner.
8. Non-structural issues shall be evalutated & designed by the appropriate professionals (i.e. "by others").
These issues include but are not limited to: access & exiting requrements, fire suppression, fire separations, acoustics, lighting, electrical, mechanical, plumbing, ventilation, emergency systems, waterproofing, grading, drainage, pest remediation, environmental hazards (e.g. mold, fungus, asbestos, etc.), and finishes.
THE DRAWINGS HEREIN ARE FOR BUILDING 55, JFTB, LOS ALAMITOS, CALIFORNIA.17.
The Documents (including drawings, calculations, specifications, data and reports) provided by Taylor & Syfan are instruments of professional service. The use of the Documents shall be restricted to the original site for which they were prepared and publication thereof is expressly limited to such use. Taylor & Syfan shall not be held responsible for modifications made to the Documents, or any products derived from them, without prior written approval by Taylor & Syfan.
11. Where special inspection is required, the Special Inspector is to obtain clearance from the Contracting Officer's Representative prior to any work commencement. Copies of the inspection report(s) shall be furnished in accordance with CBC Section 1701.3, including a copy to the Structural Engineer. The contractor is responsible for scheduling, coordination, and expenses involved in any and all inspections.
10. The specifications and notes on this sheet shall apply to and be in effect for all parts of the project, unless specifically noted otherwise.
12. In addition to the shop drawings and submittals required per the Structural Specifications, the Contractor shall provide product and material submittals for all hardware, lumber, steel, anchors, and other elements being used, to the Structural Engineer and the Project Manager for approval prior to construction of the elements in question.
The contractor is responsible for initiating a resolution to any conflicts within or between drawings and specifications by issuing an RFI. The most restrictive and most costly will apply unless otherwise stated in response to an RFI.
15.
1. Use of "Contracting Officer's Representative," or similar, in the General Notes, Specifications and Plans refers to the government building enforcement agency (or "regulatory agency" or "building department" or "building enforcement agency") with jurisdiction over design and construction of this project.
Do not scale drawings. Use written dimensions. Refer to the Architectural plans for dimensional layout.
The contractor shall verify all dimensions and conditions in the field (at the site) and report any discrepancies to the Architect and Structural Engineer before proceeding with the work. All existing conditions have not been determined or verified. Existing framing members and/or connections may be damaged in some areas. The contractor shall inspect and evaluate all framing, connections, and conditions prior to construction. The type of damage and/or extent of damage may vary from location to location. Subsequent to the contractor's inspection and evaluation of the existing conditions, the contractor shall meet with the Owner or Owner's representative to discuss the conditions.
2.
All construction projects require inspection and maintenance following completion. Operation, inspection, and maintenance are the sole responsibility of the Owner. Taylor & Syfan shall have no responsibility for any failures by the Owner or others to properly operate, inspect, or maintain the project shown in these plans.
16.
Rough Carpentry: Section 06100
Uniform Wind Load (Zone 2) 29 psf (negative) Uniform Wind Load (Zone 3) 44 psf (negative)
Seismic Force Resisting System(s) A.14** Response Modification Factor, R 2.0
Seismic Response Coefficient, Cs
0.343W
0.490 Design Base Shear (ASD ~ 0.7CsW) Redundancy Factor, ρ
Equiv. Lat. Force
1.0 Analysis Procedure Used
M/E/P dead load of at least 1 psf included in each of the design dead loads.***
SUN SHADE DESIGN LOADING
Uniform Dead Load 15 psf
Uniform Wind Load 28 psf (positive and negative)
SCOPE OF SEISMIC BRACING
SEISMIC BRACING IS LIMITED TO INSTALLATION OF A ROOF DIAPHRAGM WITH
APPROPRIATE CONNECTIONS TO EXISTING FRAMING IN CONJUNCTION WITH
THE REPLACEMENT OF THE ROOFING SYSTEM. THE ROOF DIAPHRAGM IS DESIGNED
TO ACCOMMODATE BOTH THE EXISTING SEISMIC SYSTEM OF THE BUILDING AND THE
POTENTIAL FOR A FUTURE FULL SEISMIC RETROFIT OF THE BUILDING.
6' 16'4'2'0 8'
GRAPHIC SCALE
W E S
N of
Sheet
PR
O
J.
N
O
T&
S #1
D at e C hk d.
R ev is io ns
D ra w n
C hk d.
D at e
Sy m
D es cr ip
D at e B y
G W
M E
LM
C on su lta nt
B U
IL
D
IN
G
R
EN
O
VA
TI
O
N S
Sh t T itl e
Pr oj ec t
/0
1/
/0 1/
IS
SU
ED
F O
R
CO
N
ST
RU
CT
IO
N
/1
2/
G W
M v = 141 plf v = 141 plf
Seismic Diaphragm Force:
7.41 psf (ASD)
East-West Direction
Seismic Diaphragm Force:
7.41 psf (ASD)
North-South Direction v = 267 plf v = 267 plf v = 133 plf v = 133 plf v = 356 plf v = 356 plf v = 74 plf v = 74 plf v = 267 plf
12'-0"
38'-0"
96'-0"36'-0"72'-0"20'-0"
12'-0" v = 267 plf
40'20'10'0
GRAPHIC SCALE
W E S
N
6 6
(E) SHEAR LINE
(E) SHEAR LINE
S-2
R O
O F
FR
AM
IN
G
P
LA
N
SCALE:
1/8"=1'-0"ROOF FRAMING PLAN
REMOVE AND REPLACE (E) DAMAGED FRAMING LUMBER (RAFTERS,
BLOCKING, AND ACCESSORIES) IN-KIND.
1.
REMOVE (E) SHAPED WOOD LOOKOUTS AT OVERHANGS. PROVIDE NEW
OVERHANG MATERIALS AND CONNECTION PER DETAIL 3 / S-4.
3.
CONSTRUCTION/DEMO NOTES
2. REMOVE (E) PLYWOOD OR 1x ROOF SHEATHING AND REPLACE WITH NEW 5/8" CDX PLYWOOD (OR "OSB") PI 24/0 W/ 10d COMMON NAILS @ 6", 6", 12"
(NOTE THAT SHEATHING LAYOUT SHOWN ON THE ROOF PLAN IS
DIAGRAMMATIC ONLY AND NOT TO SCALE.)
REMOVE (E) SHAPED WOOD LOOKOUTS AT OVERHANGS. PROVIDE NEW
OVERHANG MATERIALS AND CONNECTION WITHIN 4'-0" OF BUILDING
CORNERS PER DETAIL 8 / S-4.
4.
REMOVE (E) WOOD FRAMED DOOR ENTRY CANOPIES AND SUPPORTING POSTS.
REPLACE WITH NEW ALUMINUM CANOPIES PER DETAILS 2 / S-4 & 11 / S-4.
5.
(E) SHEARWALL LOCATIONS IN NORTH-SOUTH DIRECTION6.
See Note #4
S ee
N ot e #4
S ee
N ot e #4
See Note #4
See Note #4
S ee
N ot e #4
S ee
N ot e #4
See Note #4
S
LO
P E
S
LO
P E
Typical Across Roof
4'-0" 4'-0"
4' -0
4'-0"
4' -0
4' -0
4'
-0
4'-0"
5 5
712'-0"
12'-0"
1 2
Typical
Across Roof
RIDGE LINE
96'-0" V.I.F.36'-0" V.I.F.72'-0" V.I.F.20'-0" V.I.F.
'-0
" V .I.
F.
Typical Across Roof
SCALE:
1/32"=1'-0"ROOF DIAPHRAGM SHEAR DIAGRAM
REMOVE (E) PLYWOOD OR 1x ROOF SHEATHING AND REPLACE WITH NEW 5/8" CDX PLYWOOD (OR "OSB") PI 24/0 OVER 2x BLOCKING FOR EXTENT SHOWN W/ 10d COMMON NAILS @ 4", 4", 12"
7.
INSTALL TWO LINES OF ROOF NAILING OVER EXISTING SHEARWALLS.
SEE DETAIL 10/S-4.
8.
of
Sheet
PR
O
J.
N
#1
D at e C hk d.
R ev is io ns
D ra w n
C hk d.
D at e
Sy m
D es cr ip
D at e B y
G W
M E
LM
B U
IL
D
IN
G
R
EN
O
VA
TI
O
N S
Sh t T itl e
Pr oj ec t
P rim e:
EER
/0
1/
/0 1/
IS
SU
ED
F O
R
CO
N
ST
RU
CT
IO
N
/1
2/
G W
M
See Note #4
See Note #4
See Note #4
See Note #4
See Note #4
See Note #4
See Note #4
See Note #4
S-3
EL
EV
A
TI
O N
S
SCALE:
1/8"=1'-0"NORTH ELEVATION
REMOVE AND REPLACE (E) DAMAGED FRAMING LUMBER (RAFTERS,
BLOCKING, AND ACCESSORIES) IN-KIND.
1.
REMOVE (E) SHAPED WOOD LOOKOUTS AT OVERHANGS. PROVIDE NEW
OVERHANG MATERIALS AND CONNECTION PER DETAIL 3 / S-4.
3.
CONSTRUCTION NOTES
2. REMOVE (E) PLYWOOD OR 1x ROOF SHEATHING AND REPLACE WITH NEW 5/8" CDX PLYWOOD (OR "OSB") PI 24/0 W/ 10d COMMON NAILS @ 6", 6", 12" EXCEPT WHERE
SHOWN OTHERWISE (NOTE THAT SHEATHING LAYOUT SHOWN ON THE ROOF PLAN
IS DIAGRAMMATIC ONLY AND NOT TO SCALE.)
REMOVE (E) SHAPED WOOD LOOKOUTS AT OVERHANGS. PROVIDE NEW
OVERHANG MATERIALS AND CONNECTION WITHIN 4'-0" OF BUILDING
CORNERS PER DETAIL 8 / S-4.
4.
REMOVE (E) WOOD FRAMED DOOR ENTRY CANOPIES AND SUPPORTING POSTS.
REPLACE WITH NEW ALUMINUM CANOPIES PER DETAILS 2 / S-4 & 11 / S-4.
5.
PROVIDE A BID OPTION FOR MANUFACTURED ALUMINUM SUN SHADES OVER
(E) WINDOW OPENINGS AT SECOND STORY PER DETAIL 7/S-4.
10.
SCALE:
1/8"=1'-0"WEST ELEVATION
6' 16'4'2'0 8'
GRAPHIC SCALE
SCALE:
1/8"=1'-0"SOUTH ELEVATION 1
SCALE:
1/8"=1'-0"EAST ELEVATION 2
PROVIDE INFILL FRAMING AT (E) OPENING PER DETAIL 5/S-49.
PROVIDE A BID OPTION FOR MANUFACTURED ALUMINUM SUN SHADES OVER
(E) WINDOW OPENINGS AT FIRST STORY PER DETAIL 8/S-4.
11.
1 21 2
1 2
4'-0"4'-0"
4'-0" 4'-0"
10 TYP.10TYP.
10 10
11TYP.
4'-0"4'-0"4'-0" 4'-0"
10 TYP.
11 TYP.11 TYP.
of
Sheet
PR
O
J.
N
#1
D at e C hk d.
R ev is io ns
D ra w n
C hk d.
D at e
Sy m
D es cr ip
D at e B y
G W
M E
LM
B U
IL
D
IN
G
R
EN
O
VA
TI
O
N S
Sh t T itl e
Pr oj ec t
P rim e:
N
/0
1/
IS
SU
ED
F O
R
CO
N
ST
RU
CT
IO
N
/1
2/
G W
M
S-4
S
TR
U C
TU
R A L
D
ET
AI
LS
1/
2" M
IN
TY
P
ALUMINUM DOOR CANOPY BRACE
@ 3'-0" o.c. MAX. (MUST BE ABLE TO
SUPPORT TENSION & COMPRESSION)
THROUGH-BOLTED CONNECTION.
(DESIGN BY DOOR CANOPY MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
(1) A35 EA. STUD TO
TOP PLATES FULL LENGTH
OF DOOR CANOPY
1/
2" M
IN
1/
2" M
IN
TY
P
(E) 2-2X6
TOP PLATES
(E) WALL FRAMING
1/
2" M
IN
3'-6" MAX.
ALUMINUM DOOR CANOPY
HORIZONTAL MEMBER @ 3'-0" o.c. MAX.
THROUGH-BOLTED
CONNECTION.
(DESIGN BY
DOOR CANOPY MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
(1) A35 EA. STUD TO
HEADER FULL LENGTH
OF DOOR CANOPY
- 1
'-4
(2) H2.5 CLIPS RIM TO
FLOOR JOIST EA. JOIST
FULL LENGTH OF CANOPY
EXISTING HEADER
1" M
IN
TY
P
18" MAX.
DIM. PER ARCHPLYWOOD GRADE
AND NAILING
PER PLAN
(E) 2X10 ROOF RAFTERS
2X6 FASCIA
PER ARCH
(E) FRAMING PER PLAN
PROVIDE 2X10 RIM
2X12 RIM SISTERED
TO NEW RIM
(2) #8 WOOD TOE SCREWS,
TOP & BOTTOM EACH OUTRIGGER
2X6 PRESSURE BLOCKING
2X6 OUTRIGGERS
@ 24" O.C. MAX.
A35 to Rim
ST18 @ 24" O.C. AT OUTRIGGERS
1/
2" M
IN
TY
P
ALUMINUM
SUN SHADE BRACE
@ 3-0" o.c. MAX.
(MUST BE ABLE TO
SUPPORT TENSION
& COMPRESSION)
THROUGH-BOLTED CONNECTION.
(DESIGN BY SUN SHADE MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
(1) A35 EA. STUD TO
TOP PLATES FULL LENGTH
OF SUN SHADE
1/
2" M
IN
1" M
IN
TY
P
ROOF
FRAMING
1/
2" M
IN
3'-0" MAX.
ALUMINUM SUN SHADE
HORIZONTAL MEMBER @ 3'-0" o.c. Max.
(1) A35 EA. STUD TO
HEADER FULL LENGTH
OF SUN SHADE
(E) 2-2X6
TOP PLATES+/
- 1 '-4
THROUGH-BOLTED
CONNECTION.
(DESIGN BY
SUN SHADE MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
(2) H2.5 CLIPS RIM TO
FLOOR JOIST EA. JOIST
FULL LENGTH OF SUN SHADE
(E) Header
(E) Trimmer Stud Ea. Side
(E) King Stud Ea. Side
New 2x Studs @ 16"o.c.
w/ (4) 8d toenails top & bot.
New 2x PT and AB @ 48"o.c.
SCALE:
1"=1'-0"DOOR CANOPY 11
SCALE:
1/4"=1'-0"DOOR CANOPIES PLAN VIEW 2
SCALE:
1"=1'-0"TYPICAL ROOF OVERHANG 3SCALE:
1"=1'-0"ROOF OVERHANGS AT CORNERS 8
SCALE:
1"=1'-0"SUN SHADE AT FLOOR FRAMING 9 SCALE:
1"=1'-0"SUN SHADE AT ROOF FRAMING 4
SCALE:
NONEINFILL (E) DOOR 5
1" M
IN
TY
P
18" MAX.
DIM. PER ARCHPLYWOOD GRADE
AND NAILING
PER PLAN
(E) 2X10 ROOF RAFTERS
2X6 FASCIA
PER ARCH
(E) FRAMING PER PLAN
PROVIDE 2X10 RIM
2X12 RIM SISTERED
TO NEW RIM
(2) #8 WOOD TOE SCREWS,
TOP & BOTTOM EACH OUTRIGGER
2X6 PRESSURE BLOCKING
2X6 OUTRIGGERS
@ 16" O.C. MAX.
A35 to Rim
ST18 @ 24" O.C. AT OUTRIGGERS
(E) 2-2X6
TOP PLATES
(E) WALL FRAMING
THROUGH-BOLTED
CONNECTION.
(DESIGN BY
SUN SHADE MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
A35 EACH END
BLOCKING TO STUD
FULL LENGTH OF SUN SHADE
BLOCKING AT SUN SHADE BRACE
EXISTING HEADER2
1/
2" M
IN
TY
P
ALUMINUM SUN SHADE BRACE
@ 3'-0" o.c. MAX. (MUST BE ABLE TO
SUPPORT TENSION & COMPRESSION)
THROUGH-BOLTED CONNECTION.
(DESIGN BY SUN SHADE MFR..,
USE CARRIAGE HEADS
WHERE POSSIBLE)
1/
2" M
IN
1/
2" M
IN
3'-6" MAX.
ALUMINUM SUN SHADE
HORIZONTAL MEMBER @ 3'-0" o.c. MAX.
- 1
'-4
BID OPTION: BID OPTION:
BID OPTION:
SCALE:
1"=1'-0"SHEARWALL TO ROOF FRAMING 10
EXISTING RAFTER TO
TOP PLATE FASTENERS (VIF)
EXISTING
ROOF FRAMING
WHERE OCCURS
EXISTING WALL PER PLAN
PLYWOOD GRADE AND NAILING
PER PLAN
SHEARWALL
WHERE OCCURS
PER PLAN
TWO LINES OF ROOF NAILING,
STAGGER NAILING 1/2" MAX.
3'-6"
M A
TC
H
(E ) W
ID
TH
3' -6
MATCH (E) WIDTH
DOOR ENTRY CANOPY,
AS OCCURS PER PLAN,
PER DETAIL 11/ S-4
MATCH (E) WIDTH
3' -6
(E) EXTERIOR WALL (E) EXTERIOR WALL
DOOR ENTRY CANOPY,
AS OCCURS PER PLAN,
PER DETAIL 11/ S-4
DOOR ENTRY CANOPY,
AS OCCURS PER PLAN,
PER DETAIL 11/ S-4
EAST ENTRY DOOR
NORTH ENTRY DOORNORTH ENTRY DOOR
/ASCII85EncodePages false /AllowTransparency false /AutoPositionEPSFiles true /AutoRotatePages /All /Binding /Left /CalGrayProfile (Dot Gain 20%) /CalRGBProfile (sRGB IEC61966-2.1) /CalCMYKProfile (U.S. Web Coated \050SWOP\051 v2) /sRGBProfile (sRGB IEC61966-2.1) /CannotEmbedFontPolicy /Warning /CompatibilityLevel 1.4 /CompressObjects /Tags /CompressPages true /ConvertImagesToIndexed true /PassThroughJPEGImages true /CreateJDFFile false /CreateJobTicket false /DefaultRenderingIntent /Default /DetectBlends true /ColorConversionStrategy /LeaveColorUnchanged /DoThumbnails false /EmbedAllFonts true /EmbedJobOptions true /DSCReportingLevel 0 /EmitDSCWarnings false /EndPage -1 /ImageMemory 1048576 /LockDistillerParams false /MaxSubsetPct 100 /Optimize true
/OPM 1
/ParseDSCComments true /ParseDSCCommentsForDocInfo true /PreserveCopyPage true /PreserveEPSInfo true /PreserveHalftoneInfo false /PreserveOPIComments false /PreserveOverprintSettings true /StartPage 1 /SubsetFonts true /TransferFunctionInfo /Apply /UCRandBGInfo /Preserve /UsePrologue false /ColorSettingsFile () /AlwaysEmbed [ true /NeverEmbed [ true /AntiAliasColorImages false /DownsampleColorImages true /ColorImageDownsampleType /Bicubic /ColorImageResolution 300 /ColorImageDepth -1 /ColorImageDownsampleThreshold 1.50000 /EncodeColorImages true /ColorImageFilter /DCTEncode /AutoFilterColorImages true /ColorImageAutoFilterStrategy /JPEG /ColorACSImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] /ColorImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] /JPEG2000ColorACSImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 /JPEG2000ColorImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 /AntiAliasGrayImages false /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] /GrayImageDict << /QFactor 0.15 /HSamples [1 1 1 1] /VSamples [1 1 1 1] /JPEG2000GrayACSImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 /JPEG2000GrayImageDict << /TileWidth 256 /TileHeight 256 /Quality 30 /AntiAliasMonoImages false /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict << /K -1 /AllowPSXObjects false /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 /PDFXOutputIntentProfile () /PDFXOutputCondition () /PDFXRegistryName (http://www.color.org) /PDFXTrapped /Unknown
/Description << /FRA <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> /ENU (Use these settings to create PDF documents with higher image resolution for improved printing quality. The PDF documents can be opened with Acrobat and Reader 5.0 and later.)
/JPN <FEFF3053306e8a2d5b9a306f30019ad889e350cf5ea6753b50cf3092542b308000200050004400460020658766f830924f5c62103059308b3068304d306b4f7f75283057307e30593002537052376642306e753b8cea3092670059279650306b4fdd306430533068304c3067304d307e305930023053306e8a2d5b9a30674f5c62103057305f00200050004400460020658766f8306f0020004100630072006f0062006100740020304a30883073002000520065006100640065007200200035002e003000204ee5964d30678868793a3067304d307e30593002> /DEU <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> /PTB <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> /DAN <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> /NLD <FEFF004700650062007200750069006b002000640065007a006500200069006e007300740065006c006c0069006e00670065006e0020006f006d0020005000440046002d0064006f00630075006d0065006e00740065006e0020007400650020006d0061006b0065006e0020006d00650074002000650065006e00200068006f0067006500720065002000610066006200650065006c00640069006e00670073007200650073006f006c007500740069006500200076006f006f0072002000650065006e0020006200650074006500720065002000610066006400720075006b006b00770061006c00690074006500690074002e0020004400650020005000440046002d0064006f00630075006d0065006e00740065006e0020006b0075006e006e0065006e00200077006f007200640065006e002000670065006f00700065006e00640020006d006500740020004100630072006f00620061007400200065006e002000520065006100640065007200200035002e003000200065006e00200068006f006700650072002e> /ESP <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> /SUO <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> /ITA <FEFF00550073006100720065002000710075006500730074006500200069006d0070006f007300740061007a0069006f006e00690020007000650072002000630072006500610072006500200064006f00630075006d0065006e00740069002000500044004600200063006f006e00200075006e00610020007200690073006f006c0075007a0069006f006e00650020006d0061006700670069006f00720065002000700065007200200075006e00610020007100750061006c0069007400e00020006400690020007300740061006d007000610020006d00690067006c0069006f00720065002e0020004900200064006f00630075006d0065006e00740069002000500044004600200070006f00730073006f006e006f0020006500730073006500720065002000610070006500720074006900200063006f006e0020004100630072006f00620061007400200065002000520065006100640065007200200035002e003000200065002000760065007200730069006f006e006900200073007500630063006500730073006900760065002e> /NOR <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> /SVE <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> >> setdistillerparams /HWResolution [2400 2400] /PageSize [612.000 792.000] >> setpagedevice
File details come from the government source that posted it. Updated .