Amendment_0004.pdf
PDF 68 KB Posted
- Attached to
- Renovation of BLDG 620 Federal contract opportunity
- Solicitation number
- W9124M-16-B-0020
About this file
Amendment 0004
View the file
Other files for this federal contract opportunity
Show all 26
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
0010866929 WG-33-8J
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
a. The purpose of this amendment is to extend the Bid Opening date from 15 November 2016 to 30 November 2016 @ 2:00pm and to provide Questions and Answ ers:
b. All other Terms and Conditions of this solicitation remain unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 10-Nov-2016
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W9124M-16-B-0020
X 9B. DATED (SEE ITEM 11)
09-Sep-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
10-Nov-2016
CODE
MISSION & INSTALLATION CONTRACTING CMND
MICC-FORT STEWART
976 WILLIAM H WILSON AVE SUITE 100
FORT STEWART GA 31314-3425
W9124M 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W9124M-16-B-0020
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 30 - BLOCK 14 CONTINUATION PAGE
The following have been added by full text:
QUESTIONS AND ANSWERS 10 NOV16
Questions and Answers dated 10 November 2016 Question:
Section 10 14 00.20 Interior Signage describes the Interior Sign Product but I did not find any specific details or elevation drawings specifically addressing the signs. Are there any such documents for this project ?
Answer: In the spec section 10-14-00.20 the referenced guidelines include 36 CFR 1191 where the mounting heights and locations for mounting are found.
Information from Spec - Acrylic signs, surface mounted preferred.
Fonts to be in compliance with referenced codes for size location and font types.
Grey is to be the sign color with white raised letters Brail for the upper part with only room number.
Lower part to have removable section for space names to be changed out. Prefer clear window for paper labels to be inserted. (Incorporated are samples of previous signage submittals)
The following have been modified:
QUESTIONS AND ANSWERS
1. Please confirm and indicate what the existing structure consists of for the basement and the 3 above grade floors. (i.e. Exposed steel structure? Exposed concrete? Exposed wood or other combustibles?)
Answer: See attached RFI Response A – Original building
2. What does the building roof structure consist of? (i.e. Bar joists? I‐Beams? Concrete? Wood?)
Answer: See attached RFI Response A – Original Building
3. No reference has been found on the height of the wire partitions in the basement. Please identify the height of the fence if not to underside of deck. If partition extends to underside of deck please confirm if a wire ceiling is required per the finish schedule on sheet A‐602. (it is assumed that the abbreviation FNC is for the wire mesh partitions)
Answer: Floor to floor height on existing plans is shown as 10’‐8”. Therefore maximum height of the wire partitions will be @9’‐10”; no ceiling will be required if taken to underside of structure and secured.
FNC = Wire Partition
4. If a wire mesh ceiling is required, is the light fixtures allowed to be installed within the cage and supported from the cage?
Answer: Due to low existing structure the lights will be within the caged areas. See note 3 response, no ceilings.
SECTION A - SOLICITATION/CONTRACT FORM
The required response date/time 30-Nov-2016 02:00 PM has been added.
The required performance has changed from PROJECT TITLE: Renovate Bldg. 620 at Fort Stewart (Subject to the Availability of Funds (SAF))PROJECT LOCATION: Fort Stewart GeorgiaSET ASIDE: 8(a) CompetitiveNAICS CODE: 236220 Commercial and Institutional Building ConstructionSIZE STANDARD: $36.5 MillionMAGNITUDE OF CONSTRUCTION PROJECT: The estimated value of the proposed work is between $5,000,000 and $10,000,000All work shall be completed per Scope of Work, Terms, Conditions, Provisions, Clauses, Drawings and Specifications.PREBID MEETING/SITE VISIT: Will be held for this requirement: 9:00 AM 20 Sep 2016DUE DATE FOR ALL QUESTIONS: 22 Sep 2016 COBBID OPENING: The bid opening is scheduled at 14:00 27 Sep 2016, 976 William H. Wilson Ave, Building 621, Suite 101 Conference Room Fort Stewart GA 31535BONDS: Bid Bond, Payment Bond, and Performance Bonds shall all be required. MINIMUM GUARANTEE: No Minimum guarantee to PROJECT TITLE: Renovate Bldg. 620 at Fort Stewart (Subject to the Availability of Funds (SAF))PROJECT LOCATION: Fort Stewart GeorgiaSET ASIDE: HubZoneNAICS CODE:
236220 Commercial and Institutional Building ConstructionSIZE STANDARD: $36.5 MillionMAGNITUDE OF CONSTRUCTION PROJECT: The estimated value of the proposed work is between $5,000,000 and $10,000,000All work shall be completed per Scope of Work, Terms, Conditions, Provisions, Clauses, Drawings and Specifications.PREBID MEETING/SITE VISIT: Will be held for this requirement: 1:00 PM 27 Oct 2016DUE DATE FOR ALL QUESTIONS: 1 Nov 2016 4:00 pmBID OPENING: The bid opening is scheduled at 14:00 15 Nov 2016, 976 William H. Wilson Ave, Building 621, Suite 101 Conference Room Fort Stewart GA 31535BONDS:
Bid Bond, Payment Bond, and Performance Bonds shall all be required. MINIMUM GUARANTEE: No Minimum guarantee .
SECTION L - INSTRUCTIONS, CONDITIONS AND NOTICES TO BIDDERS
The following have been modified:
52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995)
(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.
(b) An organized site visit has been scheduled for – Thursday, 27 Oct 2016 @ 01:00pm
(c) Pariticipants will meet at – Building 621, Suite 116 Fort Stewart, GA 31314 Facilities Conference Room
(d) Submission of Questions is Extended to 01 Nov 2016 4:00pm