Attachment3Drawing2.pdf
PDF 119 KB Posted
- Solicitation number
- W9124J-12-R-0017
About this file
Attachment 3
View the file
Other files
| File | Type | Posted |
|---|---|---|
| L_and_M_crosswalk_8_Novemeber_2012.docx | DOCX document | |
| SF_30.pdf | ||
| Region_2_Map.pdf | ||
| Industry_Questions.pdf | ||
| W9124J12R0017-0002.pdf | ||
| Amendment_0002.pdf | ||
| Attachment3Drawing4.pdf | ||
| Attachment3Drawing3.pdf | ||
| Attachment3SOW.pdf | ||
| Attachment3.pdf | ||
| Attachment3Drawing.pdf | ||
| Attachment2PPQ.pdf | ||
| Attachment4.pdf | ||
| Attachment1PPI.pdf | ||
| W9124J12R0017.pdf | ||
| W9124J12R00170001.pdf | ||
| Amendment0001.pdf |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CELL
S.P.
STOR.
FMD BUDGET S.P. P.O. CHIEF
FMD
FMD
STOR.
BUILDING
ADMIN.
# 323 c c 14’ -3 31/64 "
D1
D3
D4
D1
D2
D3
D4
D5
D6
NOT TO SCALEA-101
C4
C7
B1
A1
B2
D6
D2
338 337 336 PRIME AND PAINT NEW AREAS
USACIL DIVISION
ROOMS 336, 337, AND 338
C6
A1
A2
A3
321 317 316
319320322
CORRIDOR 315
C O
R R
B1
B2
C1
C2
C3
C4
C5
C6
RECONFIGURE CEILING GRID
RELOCATE LIGHT AND FILL IN GRID
C3
C7
H
SIZE AUTHORITY PLATE
SCALE DATE SHEET OF
DRAWING NUMBERRECOMMENDED:
APPROVED:
B
A
C
D
E
F
G
HH
G
F
E
D
C
B
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
SYMBOL BYDATEDESCRIPTION
REVISIONS
CHIEF, DESIGN SECTION
CHIEF, PUBLIC WORKS DIV., DPW
CONCURRENCE
ARCHITECT
MECHANICAL
ELECTRICAL
CIVIL
USING AGENCY
OPER DIVISION
FIRE DEPT.
ENVIRONMENTAL
PREVENTIVE
MEDICINE
NAME-DATE
EMCS
CADD TECH.
SAFETY
CONCURRENCE NAME-DATE
ESTIMATOR
NONE
DR000222P-A200
FEBRUARY 08, 2012
NOT TO SCALEA-101
NOT TO SCALEA-101
2 ROOMS 317, 321, AND 324
348346
ARCHETECTURAL
MODIFICATIONS
CONTRACTING OFFICE
A14
ROOMS 346 TO 348
E1
C8
A5
C8
E2
DEMO BRICK WALL FOR NEW DOOR
DEMOLITION NOTES:(CODED TO DEMOLITION FLOOR PLANS)
A4
C2
C1
C5
3 5/8" METAL STUDS
@ 16" O.C. WITH ONE
LAYER OF 5/8"
GYP. BD. EACH SIDE
SCHEDULED BASE & FIN. FLOOR
STRUCTURAL SLAB
4 7/8"
STRUCTURAL SLAB
STD. TOP RUNNER
ACCOUS. TILE CLG.
A2
NOTE:
AT ROOM 336 TO SWING IN.
ROOM 338 AND RE-INSTALL
DOOR REMOVED FROM
FILL OPENING TO MATCH EXISTING.
INSWING.
INSTALL RELOCATED DOOR&JAMB:
INSWING
REVERSE SWING TO LEFT HAND
MATCH ROOM 337
RECONFIGURE CEILING GRID TO
AND WIPE DOWN WITH DW-40.
OF CONSTRUCTION MATERIAL
CLEAN METAL WINDOW FRAME
D5
D7
D7
COMB TO BLEND
INSTALL MATING CARPET AND
D7
CUT CARPET TO CEMENT FLOOR
INSTALL GYPSUM WALL
A4 RELOCATE LIGHT
A3
NOTE:
AT ROOM 324 TO OUT-SWING.
ROOM 321 AND RE-INSTALL
DOOR REMOVED FROM
A5 INSTALL NEW DOOR & JAMB
A6
A6 **DO NOT CUT ENTRANCE CARPET**
" PLYWOOD INTERIOR4
3WITH
CONSTRUCT SERVER ROOM WALL
OUTSWING RIGHT HAND
INSTALL DOOR FROM ROOM 321 TO
INSTALL LEVER LOCK FROM RM
ENTRANCE
INSTALL CIPHER LOCK FROM 324
INSTALL NEW LEVER DOORKNOB
REPAIR CEILING GRID
REPLACE WINDOW SASHES WITH NEW HARDWARE
NOTE:
SERVER ROOM DOOR.
AND INSTALLED ON NEW
FROM DOOR 324 ENTRANCE
CIPHER LOCK RELOCATED
FILL IN OPENING TO MATCH
IN-SWING
INSTALL NEW DOOR & JAMB TO LEFT
A7 PRIME AND PAINT NEW AREAS
B3 PRIME AND PAINT NEW AREAS
E2
C9 PRIME AND PAINT NEW AREAS
C9
D5
B3
A7
E1
E4
E3
E3
E4
INSTALL STEEL LENTELS
FILL IN LARGE OPENING
336 INSWING LEFT
INSTALL DOOR & JAMB FROM ROOM
E5
NOTE:
AT ROOM 346 TO IN-SWING.
ROOM 336 AND RE-INSTALL
DOOR REMOVED FROM
NOT TO SCALEA-200
4 SECTION TYPICAL PARTITION WALL
NOT TO SCALEA-200
5 DOOR ELEVATION
NOT TO SCALEA-200
7 TYPICAL HEAD DETAIL
NOT TO SCALEA-200
6 TYPICAL WALL FRAMING AT DOOR
D O
O R
H E
IG
H T
K
IC
K P
L A
T E
W H
E R
E
IN
D
IC
A T
E D
T O
C
L
L E
V E
R
DOOR WIDTH
HOLLOW METAL
FRAME
SCHEDULE
DOOR - REFER TO
SOLID CORE WOOD
HOLLOW METAL OR
WHERE INDICATED
CARD READER METAL FRAME
HOLLOW
STUD
METAL
STUD RUNNER
METAL
AS SCHEDULED
PARTITION
1�" 1�"VARIES
PLANS
REFER TO
UNDERSIDE OF STRUCTURE
CHANNEL RUNNER
JAMB
DOUBLE AT EACH
METAL STUDS
CHANNEL RUNNER FASTEN
TO STUDS W/ SCREWS.
HINGE SIDE.
OCCUR DIRECTLY OPPOSITE OF
CLIPS. ON STRIKE SIDE TO
ABOVE HINGE REINFORCEMENT
LOCATE JAMB ANCHOR CLIPS
OR BOLT TO MTL. STUDS.
SHOP WELD TO DOOR FRAME,
JAMB ANCHOR CLIPS
THAN TWO FASTENERS
SECURE WITH NO LESS
FLOOR ANCHOR CLIPS.
1’
2"