CELL

S.P.

STOR.

FMD BUDGET S.P. P.O. CHIEF

FMD

FMD

STOR.

BUILDING

ADMIN.

# 323 c c 14’ -3 31/64 "

D1

D3

D4

D1

D2

D3

D4

D5

D6

NOT TO SCALEA-101

C4

C7

B1

A1

B2

D6

D2

338 337 336 PRIME AND PAINT NEW AREAS

USACIL DIVISION

ROOMS 336, 337, AND 338

C6

A1

A2

A3

321 317 316

319320322

CORRIDOR 315

C O

R R

B1

B2

C1

C2

C3

C4

C5

C6

RECONFIGURE CEILING GRID

RELOCATE LIGHT AND FILL IN GRID

C3

C7

H

SIZE AUTHORITY PLATE

SCALE DATE SHEET OF

DRAWING NUMBERRECOMMENDED:

APPROVED:

B

A

C

D

E

F

G

HH

G

F

E

D

C

B

1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

SYMBOL BYDATEDESCRIPTION

REVISIONS

CHIEF, DESIGN SECTION

CHIEF, PUBLIC WORKS DIV., DPW

CONCURRENCE

ARCHITECT

MECHANICAL

ELECTRICAL

CIVIL

USING AGENCY

OPER DIVISION

FIRE DEPT.

ENVIRONMENTAL

PREVENTIVE

MEDICINE

NAME-DATE

EMCS

CADD TECH.

SAFETY

CONCURRENCE NAME-DATE

ESTIMATOR

NONE

DR000222P-A200

FEBRUARY 08, 2012

NOT TO SCALEA-101

NOT TO SCALEA-101

2 ROOMS 317, 321, AND 324

348346

ARCHETECTURAL

MODIFICATIONS

CONTRACTING OFFICE

A14

ROOMS 346 TO 348

E1

C8

A5

C8

E2

DEMO BRICK WALL FOR NEW DOOR

DEMOLITION NOTES:(CODED TO DEMOLITION FLOOR PLANS)

A4

C2

C1

C5

3 5/8" METAL STUDS

@ 16" O.C. WITH ONE

LAYER OF 5/8"

GYP. BD. EACH SIDE

SCHEDULED BASE & FIN. FLOOR

STRUCTURAL SLAB

4 7/8"

STRUCTURAL SLAB

STD. TOP RUNNER

ACCOUS. TILE CLG.

A2

NOTE:

AT ROOM 336 TO SWING IN.

ROOM 338 AND RE-INSTALL

DOOR REMOVED FROM

FILL OPENING TO MATCH EXISTING.

INSWING.

INSTALL RELOCATED DOOR&JAMB:

INSWING

REVERSE SWING TO LEFT HAND

MATCH ROOM 337

RECONFIGURE CEILING GRID TO

AND WIPE DOWN WITH DW-40.

OF CONSTRUCTION MATERIAL

CLEAN METAL WINDOW FRAME

D5

D7

D7

COMB TO BLEND

INSTALL MATING CARPET AND

D7

CUT CARPET TO CEMENT FLOOR

INSTALL GYPSUM WALL

A4 RELOCATE LIGHT

A3

NOTE:

AT ROOM 324 TO OUT-SWING.

ROOM 321 AND RE-INSTALL

DOOR REMOVED FROM

A5 INSTALL NEW DOOR & JAMB

A6

A6 **DO NOT CUT ENTRANCE CARPET**

" PLYWOOD INTERIOR4

3WITH

CONSTRUCT SERVER ROOM WALL

OUTSWING RIGHT HAND

INSTALL DOOR FROM ROOM 321 TO

INSTALL LEVER LOCK FROM RM

ENTRANCE

INSTALL CIPHER LOCK FROM 324

INSTALL NEW LEVER DOORKNOB

REPAIR CEILING GRID

REPLACE WINDOW SASHES WITH NEW HARDWARE

NOTE:

SERVER ROOM DOOR.

AND INSTALLED ON NEW

FROM DOOR 324 ENTRANCE

CIPHER LOCK RELOCATED

FILL IN OPENING TO MATCH

IN-SWING

INSTALL NEW DOOR & JAMB TO LEFT

A7 PRIME AND PAINT NEW AREAS

B3 PRIME AND PAINT NEW AREAS

E2

C9 PRIME AND PAINT NEW AREAS

C9

D5

B3

A7

E1

E4

E3

E3

E4

INSTALL STEEL LENTELS

FILL IN LARGE OPENING

336 INSWING LEFT

INSTALL DOOR & JAMB FROM ROOM

E5

NOTE:

AT ROOM 346 TO IN-SWING.

ROOM 336 AND RE-INSTALL

DOOR REMOVED FROM

NOT TO SCALEA-200

4 SECTION TYPICAL PARTITION WALL

NOT TO SCALEA-200

5 DOOR ELEVATION

NOT TO SCALEA-200

7 TYPICAL HEAD DETAIL

NOT TO SCALEA-200

6 TYPICAL WALL FRAMING AT DOOR

D O

O R

H E

IG

H T

K

IC

K P

L A

T E

W H

E R

E

IN

D

IC

A T

E D

T O

C

L

L E

V E

R

DOOR WIDTH

HOLLOW METAL

FRAME

SCHEDULE

DOOR - REFER TO

SOLID CORE WOOD

HOLLOW METAL OR

WHERE INDICATED

CARD READER METAL FRAME

HOLLOW

STUD

METAL

STUD RUNNER

METAL

AS SCHEDULED

PARTITION

1�" 1�"VARIES

PLANS

REFER TO

UNDERSIDE OF STRUCTURE

CHANNEL RUNNER

JAMB

DOUBLE AT EACH

METAL STUDS

CHANNEL RUNNER FASTEN

TO STUDS W/ SCREWS.

HINGE SIDE.

OCCUR DIRECTLY OPPOSITE OF

CLIPS. ON STRIKE SIDE TO

ABOVE HINGE REINFORCEMENT

LOCATE JAMB ANCHOR CLIPS

OR BOLT TO MTL. STUDS.

SHOP WELD TO DOOR FRAME,

JAMB ANCHOR CLIPS

THAN TWO FASTENERS

SECURE WITH NO LESS

FLOOR ANCHOR CLIPS.

1’

2"