ATTACHMENT I

Fire Alarm/MNS Systems As-Builts for Building 61801

Building 61801 (Greely Hall) FACP Locations for Elevators 1-8

1. Elevators 1, 2, 3, 4, 5, and 6

a. The Simplex® fire alarm control panel (FACP) for elevator 1-2 and 3-4 machine rooms is located in a room labeled “A-Vault” on the 1st Floor of Building 61801.

Room “A-Vault” does not have a room number.

b. There are no smoke detectors and heat detectors in the elevator 5 and 6 machine rooms.

c. The smoke detectors and the heat detectors at the 3rd Floor elevator 1-2, 3-4, 5 and 6 lobbies are addressed to the Simplex® FACP in a room labeled “A-Vault” which has no room number.

d. The smoke detectors and the heat detectors at the 2nd Floor elevator 1-2, 3-4, 5, and 6 lobbies are addressed to the Simplex® FACP in a room labeled “A-Vault” which has no room number.

e. The smoke detectors and the heat detectors at the 1st Floor elevator 1-2, 3-4, 5, and 6 lobbies are addressed to the Simplex® FACP in Room 1012.

2. Elevator 7

a. There are no smoke detectors and heat detectors in the elevator 7 machine room.

b. The smoke detectors and the heat detectors at the 3rd Floor elevator 7 lobby are addressed to the Simplex® FACP in “E&F-Vault” which is Room 1520.

c. The smoke detectors and the heat detectors at the 2nd Floor elevator 7 lobby are addressed to the Simplex® FACP in “E&F-Vault” which is Room 1520.

d. The smoke detectors and the heat detectors at the 1st Floor elevator 7 lobby are addressed to the Simplex® FACP in “E&F-Vault” which is Room 1520.

3. Elevator 8

a. There are no smoke detectors and heat detectors in the elevator 8 machine room.

b. The smoke detectors and the heat detectors at the 3rd Floor elevator 8 lobby are addressed to the Simplex® FACP in “J&K-Vault” which is Room 1625.

c. The smoke detectors and the heat detectors at the 2nd Floor elevator 8 lobby are addressed to the Simplex® FACP in “J&K-Vault” which is Room 1625.

d. The smoke detectors and the heat detectors at the 1st Floor elevator 8 lobby are addressed to the Simplex® FACP in “J&K-Vault” which is Room 1625.

Room Manufacturer Node Zones Function 1010 Simplex Main FACP Main FACP Main FACP 1012 Simplex 4 2,2A,10 FACP

1046A Monaco Room 1046A only Room 1046A only FACP 1214 Simplex 7 2A FACP 1215 FCI Room 1215 only Room 1215 only FACP

1520 (E&F Vault) Simplex 5 1,4,7 FACP 1530M Monaco NOF (1530) only Room 1530 only FACP 1535 1A

1625 (J&K Vault) Simplex 6 3,6,9 FACP A Vault Simplex 3 5,8 FACP

LOBBY Simplex All 4100U panels report to this panel

LOC

1-Simplex 1-Monaco

Room 1700 only Room 1700 only FACP

Building 61801 (Greely Hall) FACP Locations (not conclusive of all possible FACP in Building 61801)