1.5_Drawings-ARCHITECTURE.pdf
PDF 5 MB Posted
- Attached to
- C-17 Refueling Hydrant System Ramp Expansion Federal contract opportunity
- Solicitation number
- W91242-18-R-0002
View the file
Other files for this federal contract opportunity
Show all 50
C-17 Refueling Hydrant System Ramp Expansion has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SECTION, DETAIL, AND ELEVATION SYMBOL IDENTIFIERS:
DRAWING SEQUENCE NUMBER
INDICATES WHERE TITLE IS LOCATED
(MAY NOT BE PRESENT IF CALLOUT
AND TITLE ARE ON THE SAME
DRAWING)
LETTER OR NUMBER
DESIGNATOR
ONE OR TWO CHARACTER DISCIPLINE
DESIGNATOR (MAY NOT BE PRESENT
IF CALLOUT AND TITLE ARE ON
DRAWINGS WITHIN THE SAME
DISCIPLINE)
WALL / BUILDING SECTION CALLOUT EXAMPLE:
DETAIL CALLOUT EXAMPLE:
ELEVATION CALLOUT EXAMPLE:
SECTION, DETAIL, AND ELEVATION TITLE EXAMPLE:
EXTERIORINTERIOR
N
NORTH ARROW EXAMPLE:
X#
X-###
LETTER OR NUMBER
INDICATES DETAIL
DRAWING NUMBER
WHERE SECTION IS
SHOWN
X#
X-###
A-101
SCALE:X#
VIEW NAME
1/8" = 1'-0"
LETTER OR NUMBER
INDICATES DETAIL
DESIGNATION
DRAWING NUMBER
WHERE DETAIL IS
SHOWN
A1
A1 A1
A1
X#
X-###
X#
X-###
NEW DOOR
NEW WALL (RE:
PARTITION TYPE)
PLAN LEGEND:
ROOM NAME
ROOM NUMBER
PARTITION TYPE
DOOR NUMBER
WINDOW WALL TYPE
GLAZING TYPE
LOUVER TAG
GRID BUBBLE AND LINE
TOILET ACCESSORY TAG
L1
T1
W1
888W
ROOM NAME
1i
# NEW WORK KEYNOTE TAG
RIGID INSULATION
FACE BRICK
PLYWOOD
CONCRETE
MASONRY UNIT
CONCRETE
UNDISTURBED
EARTH
GROUT OR
GYPSUM BOARD
STEEL OR
FERROUS METALS
GRAVEL
FINISHED WOOD
BATT INSULATION
MATERIAL SYMBOLS
DIMENSION
LUMBER
METAL STUD WALL
BACKER ROD
AND SEALANT
ALUMINUM OR
NON-FERROUS
METALS
SAND, PLASTER, OR
PORTLAND CEMENT
COMPACTED
FILL
TERRAZZO
GRASS
MASONRY
PARTICLE BOARD
GLUED-LAMINATED
WOOD
PLASTIC LAMINATE
2' x 2' ACOUSTICAL CEILING TILE
GYPSUM BOARD - PAINT
10' - 0" CEILING HEIGHT ABOVE
FINISH FLOOR
HVAC AIR SUPPLY GRILLE
HVAC EXHAUST OR RETURN GRILLE
STRUCTURAL STEEL BEAM - PAINT
EXPOSED CEILING
WALL MOUNTED EXTERIOR
LIGHT FIXTURE
OTS
EXIT SIGN
OPEN TO STRUCTURE-PAINTED
1' x 4' FIXTURE - SUSPENDED
2' x 4' FIXTURE - RECESSED
CEILING LEGEND:
CEILING ACCESS PANEL
1' x 4' FIXTURE - RECESSED date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
B
U R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:1
A
M
FJRP159073-A-001.dwg
A-001
94893
ARCHITECTURAL LEGEND & ABBREVIATIONS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
ABBREVIATIONS
SEE ADDITIONAL FINISH MATERIAL
ABBREVIATIONS IN THE FINISH MATERIAL
LEGEND, DRAWING A-601
-M-
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTD MOUNTED
MTL METAL
-N-
N NORTH
N/A NOT APPLICABLE
NIC NOT IN CONTRACT
NO NUMBER
NTS NOT TO SCALE
-O-
OC ON CENTER
OPP OPPOSITE
OTS OPEN TO STRUCTURE -
PAINTED
-P-
PL PLATE
PLMB PLUMBING
PLYWD PLYWOOD
PROJ PROJECT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
-R-
R/A RETURN AIR
RCP REFLECTIVE CEILING PLAN
REFER REFERENCE
REINF REINFORCED
REQ'D REQUIRED
REV REVISION
RO ROUGH OPENING
-S-
S SOUTH
S/A SUPPLY AIR
SCHED SCHEDULE
SECT SECTION
SF SQUARE FOOT
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE, AS IN "SQ FT"
STD STANDARD
STOR STORAGE
STRUCT STRUCTURAL
SUPP SUPPORT
SUSP SUSPENDED
SYS SYSTEM
-T-
TD TRENCH DRAIN
TECH TECHNICAL
THRU THROUGH
TLT TOILET
TO TOP OF, AS IN "TO STEEL"
TYP TYPICAL
-U-
UL UNDERWRITERS
LABORATORY
UNO UNLESS NOTED OTHERWISE
UTIL UTILITY
-V-
VENT VENTILATE, VENTILATOR
VOL VOLUME
-W-
W WEST, WIDTH
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
-A-
A/E ARCHITECT/ENGINEER
ACOUST ACOUSTICAL
ADJ ADJACENT, ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING
JURISDICTION
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURE, ARCHITECT
-B-
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF, AS IN "BO
STEEL"
BTWN BETWEEN
-C-
CJ CONTROL JOINT,
CONSTRUCTION JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONT CONTINUOUS
-D-
DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DS DOWNSPOUT
DWG DRAWING
-E-
E EAST
EA EACH
EEWS EMERGENCY EYEWASH &
SHOWER
EF EXHAUST FAN
ELEC ELECTRIC / ELECTRICAL
ELEV ELEVATION AS IN NORTH
ELEV
EQ EQUAL
EQUIP EQUIPMENT
ETC AND SO FORTH (ETCETERA)
EXH EXHAUST
EXIST EXISTING
EXT EXTERIOR
-F-
FDN FOUNDATION
FE FIRE EXTINGUISHER WITH
WALL BRACKET
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR
FIN FINISHED, FINISH
FLR FLOOR
FT FEET / FOOT
-G-
GA GAUGE
GALV GALVANIZED
GYP GYPSUM
GYP BD GYPSUM BOARD
-H-
H HIGH
HM HOLLOW METAL
HORIZ HORIZONTAL
HT HEIGHT
HVAC HEATING, VENTILATION & AIR
CONDITIONING
-I-
IN INCH
INSUL INSULATION
INT INTERIOR
-L-
L LEFT, LONG, LENGTH
LAV LAVATORY
LVR LOUVER
PLAN LEGENDCALL OUT IDENTIFICATION
1. ALL WORK SHALL COMPLY WITH ALL APPLICABLE CODES AND STANDARDS AS LISTED OR
REFERENCED ON LIFE SAFETY PLAN AND LIFE SAFETY CRITERIA OR AS REQUIRED BY THE
AUTHORITY HAVING JURISDICTION.
2. DIMENSIONS SHALL GOVERN. DETAILS SHALL GOVERN OVER PLANS AND ELEVATIONS.
LARGE SCALE DETAILS OR PLANS SHALL GOVERN OVER SMALL SCALE DETAILS OR PLANS.
DO NOT SCALE DRAWINGS.
3. ALL FLOORS SHALL BE INSPECTED FOR DAMAGE, WARPING OR OTHER NOTICEABLE
DEVIATIONS AND PATCHED AND LEVELED PRIOR TO COVERING WITH FLOOR FINISHES OR
ERECTION AND INSTALLATION OF COLD-FORMED FRAMING.
4. ANY MANUFACTURER'S OR BRAND NAME PRODUCTS INDICATED OR SPECIFIED ARE DONE
SO TO ESTABLISH A MINIMUM LEVEL OF QUALITY.
5. ALL CONSTRUCTION SHALL MEET OR EXCEED LOCAL INDUSTRY STANDARDS. DETAILS ARE
PROVIDED TO INDICATE MINIMUM QUALITY AND TO GIVE STANDARDS OF CONSTRUCTION.
IF A CONDITION IS NOT SPECIFICALLY DETAILED, SUBMIT A SIMILAR DETAIL FOR GUIDE AND
APPROVAL.
6. THE LETTERS I, O, AND Q ARE NOT USED TO INDICATE DETAILS, SECTIONS OR ELEVATIONS.
7. PROVIDE PRESERVATIVE-TREATED WOOD AT ALL LOCATIONS WHERE WOOD IS IN DIRECT
CONTACT WITH CONCRETE OR MASONRY.
8. PROVIDE FIRE-RESISTANT TREATED WOOD BLOCKING FOR SECURE ANCHORAGE OF ALL
SUSPENDED ITEMS, DOOR-STOPS, GRAB-BARS, AND OTHER SIMILAR WOODWORK,
HARDWARE, SPECIALTIES, ACCESSORIES, FIXTURES, OR EQUIPMENT.
9. PAINT, STAIN, OR COAT ALL EXPOSED SURFACES OF CONSTRUCTION UNLESS NOTED
OTHERWISE OR IF SURFACES ARE PRE-FINISHED.
10. ALL OPENING DIMENSIONS ARE NOMINAL. THE CONTRACTOR SHALL FIELD MEASURE ALL
OPENINGS AND COORDINATE WITH THE APPROPRIATE SUPPLIER FOR ALL DOORS AND
WINDOWS.
11. ALL CONDUITS, PLUMBING, PIPING, DUCTWORK, AND OTHER EQUIPMENT EXPOSED TO
VIEW SHALL BE LOCATED PARALLEL OR PERPENDICULAR TO THE STRUCTURAL FRAMING
SYSTEM.
12. PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS, WHERE REQUIRED.
13. ARCHITECTURAL DETAILS ARE APPLICABLE WHERE INDICATED BY SECTION CUT, BY NOTE, OR BY DETAIL TITLE. INCORPORATE SIMILAR DETAILS AT SIMILAR CONDITIONS UNLESS
NOTED OTHERWISE. THE CONTRACTOR MAY REQUEST A CLARIFICATION IF REQUIRED,
OTHERWISE THE MORE STRINGENT REQUIREMENTS SHALL CONTROL.
14. PROVIDE FIRE-STOPPING SYSTEMS AT TOP OF AND AT ALL PENETRATIONS THROUGH
FIRE-RATED PARTITIONS.
15. SEAL ALL EXTERIOR BUILDING JOINTS AT BOTH THE EXTERIOR AND INTERIOR SURFACES
AGAINST MOISTURE AND AIR INFILTRATION.
16. SEAL AROUND ALL DOOR AND WINDOW FRAMES, WALL-MOUNTED FIXTURES AND
EQUIPMENT TO ADJACENT WALL SURFACES.
17. THE CONTRACTOR SHALL REVIEW THE DIMENSIONS OF ALL EQUIPMENT IN THE PROJECT
REGARDLESS OF THE SOURCE AND COORDINATE ACCESS TO THE SPACE AND VERIFY
CLEAR FLOOR SPACE IS PROVIDED AS REQUIRED TO ENSURE EASE OF INSTALLATION.
18. ALL WORK MUST BE OF GOOD QUALITY, FREE FROM DEFECTS, AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CONTRACT DOCUMENTS.
19. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PENETRATIONS IN
THE STRUCTURE FOR THE PROPER INSTALLATION OF THE WORK. REFER TO STRUCTURAL
DRAWINGS FOR SECONDARY FRAMING AND OR REINFORCING REQUIRED AT
PENETRATIONS IN STEEL, CONCRETE OR MASONRY.
20. BRACE PARTITIONS, SUSPENDED CEILINGS, SOFFITS, SUSPENDED ITEMS, ETC. ONLY TO
STRUCTURAL ELEMENTS ABOVE. DO NOT ANCHOR TO ROOF DECK, PLUMBING / SPRINKLER
PIPES, DUCTWORK, ELECTRICAL CONDUIT OR SIMILAR ELEMENTS.
21. EXTEND ALL FLOORING AND WALL-BASE COMPLETELY INTO RECESSES AND BEHIND ALL
EQUIPMENT.
22. ALL MATERIALS USED FOR CONSTRUCTION SHALL BE NEW AND UNDAMAGED. THE
CONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR ALL WORK SHOWN.
23. THE CONTRACTOR SHALL BECOME FULLY ACQUAINTED WITH CONDITIONS RELATED TO
THE WORK. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE ACTUAL CONDITIONS
SHALL BE REPORTED TO THE DESIGN PROFESSIONALS FOR RESOLUTION PRIOR TO
PROCEEDING WITH THE WORK.
24. DRAWINGS CONTAINED IN THIS SET SHALL NOT BE REPRODUCED FOR SHOP DRAWINGS.
COPIES OF THESE DRAWINGS SUBMITTED AS SHOP DRAWINGS WILL BE REJECTED AND
RETURNED TO THE CONTRACTOR.
25. EACH INSTALLER MUST EXAMINE SUBSTRATE AND/OR CONDITIONS UNDER WHICH THE
WORK WILL BE INSTALLED AND REPORT TO THE CONTRACTOR IN WRITING ANY
CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY EXECUTION OF THE INSTALLERS
WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS ARE CORRECTED.
INSTALLATION SHALL CONSTITUTE ACCEPTANCE OF THE SUBSTRATE AND/OR CONDITIONS.
26. "TYPICAL" (TYP) AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITIONS OR
DIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.
27. CONTROL JOINTS (CJ) SHALL BE INSTALLED AT ALL PARTITIONS. CJ AT GYPSUM
PARTITIONS SHALL BE MAXIMUM 30'-0" O.C., CJ AT CONCRETE MASONRY UNIT PARTITIONS
SHALL BE MAXIMUM 20'-0" O.C., UNLESS OTHERWISE NOTED ON DRAWINGS. REVIEW CJ
LOCATIONS WITH ARCHITECT PRIOR TO INSTALLATION.
28. NON-BEARING PARTITIONS SHALL BE ISOLATED FROM THE BUILDING STRUCTURE TO
PREVENT TRANSFER OF BUILDING LOADS FROM THE STRUCTURE TO THE PARTITIONS.
GENERAL NOTES
0 10/13/17 B-3 FINAL SUBMITTAL LS
A
A-201
B3
A-201
C1
2 3 4
B
C
D
7' - 4"
1' - 6" 24' - 0" 24' - 4" 24' - 0" 1' - 6"
16' - 8"
A3
A-311
A1
A-311
5' - 10 1/2" 11"
CONTROL ROOM
MEN'S/WOMEN'S
TOILET
MECH ROOM
STORAGE
PUMP ROOM
A2
A-311
C1
A-301
102B
102A
W1
W1
C1
A-401
P2A
P1A
P1B
A-201
B1
A-201
C3
C3
A-301
B1
A-301
2' - 4"
P2B
P3
102C
102D
1 1
TYP
75' - 4"
1' - 2"
P2B
SLOPE
1' - 1 1/2"
17' - 6"
TYP
P3
P3
TYP
GENERAL NOTES: THIS DRAWING ONLY
1.
2.
3.
4.
5.
6.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL
LEGEND, AND ABBREVIATIONS REFER TO DRAWING
A-001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE
RATED WALL LOCATIONS. ALL FIRE RATED WALLS
AND SMOKE PARTITIONS ARE CONTINUOUS ACROSS
ALL OPENINGS.
ALL INTERIOR DIMENSIONS ARE FACE OF STUD OR
FACE OF CMU, UNO.
THE FINISHED FLOOR ELEVATION OF CONTROL
ROOM IS 100'-0", UNO.
DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES
FROM FACE OF GYPSUM BOARD WALL TO DOOR
JAMB EXTERIOR EDGE.
FOR PARTITION TYPES CONSTRUCTION AND
DESCRIPTION, REFER TO PARTITION TYPES
DRAWING A-501.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:1
A
M
FJRP159073-A-101.dwg
A-101
94893
FLOOR PLAN
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 1/4" = 1'-0"A1
FLOOR PLAN
0 2' 4' 8'
N
KEY NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
PUMP FOUNDATION; RE: STRUCT DWGS.
ELECTRICAL EQUIPMENT; RE: ELEC DWGS.
CONCRETE RAMP; RE: STRUCT DWGS.
TRENCH; RE: STRUCT DWGS.
EQUIPMENT PAD; RE: STRUCT DWGS.
EDGE OF ROOF ABOVE.
CONCRETE DOOR STOOP; RE: STRUCT DWGS.
EMERGENCY EYE WASH AND SHOWER.
PIPE SUPPORT PEDESTALS; RE: STRUCT
DWGS.
X
A
B
C
D
MECH ROOM
STORAGE
MEN'S/WOMEN'S
TOILET
CONTROL ROOM
OTS
8' - 0" A.F.F.8' - 0" A.F.F.
9' - 0" A.F.F.
E Q
E Q
EQ EQ
EQ EQ
A
2 3 4
B
C
D
S L O
P E
S L O
P E
17' - 6"
A
2 3 4
B
C
D
C1
A-301
STORAGE
MECH ROOM
MEN'S/WOMEN'S
TOILET
CONTROL ROOM
PUMP ROOM
A3
A-102
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO DRAWING A-001.
ARCHITECTURAL CEILING PLANS INDICATE DIMENSIONING AND
PLACEMENT OF VARIOUS CEILING MOUNTED DEVICES. REFER TO MEP
DRAWINGS AND SPECIFICATIONS FOR ALL OTHER INFORMATION FOR MEP
SYSTEMS INCLUDING BUT NOT LIMITED TO FIRE SUPPRESSION, FIRE
ALARM DEVICES, SECURITY DEVICES, EXIT DEVICES, DIFFUSERS,
LIGHTING, LIGHTING CONTROL DEVICES, AND ACCESS PANELS.
CEILING HEIGHTS ARE SHOWN TO HEIGHT ABOVE FINISH FLOOR.
ALL CEILING GRIDS TO BE CENTERED IN ROOMS UNLESS NOTED
OTHERWISE.
ALL LIGHTS, SPEAKERS, SPRINKLERS, SIGNAGE, STROBES AND OTHER
HARDWARE INSTALLED IN TILED CEILING SYSTEMS TO BE CENTERED IN
TILES IN BOTH DIRECTIONS UNLESS NOTED OTHERWISE.
REFERENCE ROOM FINISH SCHEDULE FOR ADDITIONAL CEILING FINISH
INFORMATION.
CENTER CEILING MOUNTED EXIT SIGNS WITHIN DOOR FRAME OR
OPENING. MOUNT 4" OFF FACE OF WALL.
ALIGN ALL SPRINKLERS, JUNCTION BOXES & SMOKE DETECTORS WITH
ADJACENT LIGHT FIXTURES, UNLESS NOTED OTHERWISE.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT RESTROOM
CEILINGS.
GENERAL NOTES: THIS DRAWING ONLY
1.
2.
3.
4.
5.
6.
7.
8.
9.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:1
A
M
FJRP159073-A-102.dwg
A-102
94893
REFLECTED CEILING PLAN & ROOF PLAN
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 1/4" = 1'-0"A3
REFLECTED CEILING PARTIAL PLAN
SCALE: 1/8" = 1'-0"C1
ROOF PLAN
SCALE: 1/8" = 1'-0"A1
REFLECTED CEILING PLAN
0 4' 8' 16'
0 4' 8' 16' 0 2' 4' 8'
N
N N
ROOF DRAINAGE CALCULATIONS
ROOF AREA SLOPE
AREA
(SF)
PITCH
FACTOR
(SMACNA
TABLE 1-1)
ADDED
ROOF AREA
(SF)
TOTAL
AREA (SF)
DOWNSPOUT
QTY
TOTAL AREA
PER
DOWNSPOUT
DS
AREA/330
(SI) 100 YR
MINIMUM DOWNSPOUT
DIMENSION IPC (TABLE
1106.2(2) RAINFALL RATE: 100
YEAR FREQUENCY 3.7 IN/HR)
MINIMUM GUTTER
DIMENSION IPC (TABLE 116.6
RAINFALL RATE: 100 YEAR
FREQUENCY 3.7 IN/HR) 3/12
SLOPE
CANOPY 3/12 2,131 1.00 0 2,131 4 533 1.62 2" RECTANGULAR REQUIRED
3" X 4" PROVIDED (NOTE 2)
4" X 4" REQUIRED
5" X 5" PROVIDED
ROOF DRAINAGE NOTES:
MAIN ROOF DOWNSPOUTS TO DEPOSIT ABOVE
GRADE AT CONCRETE SPLASHBLOCKS.
PER SMACNA, DOWNSPOUTS OF LESS THAN 7" SQ.
CROSS SECTION SHOULD NOT BE USED.
1.
2.
KEY NOTES:
1.
2.
3.
4.
5.
6.
12" x 12" CEILING ACCESS PANEL.
STRUCTURAL FRAMING MEMBERS, TYP.
STANDING SEAM METAL ROOFING.
RIDGE FLASHING.
GUTTER.
PREFINISHED METAL DOWNSPOUT, TYP. OF 4.
X
100' - 0" AFF
FINISH FLOOR
A B C D
116' - 6" AFF
T.O. STEEL
PREFINISHED
GUTTER &
DOWNSPOUT
PREFINISHED
METAL WALL
PANEL
CONCRETE
SPLASHBLOCK
L1
PREFINISHED
METAL FASCIA
3' - 10" 5' - 4"
EXHAUST VENT;
SEE MECH
4" SPLIT FACE
CMU
EXTERIOR LIGHT,
TYP; RE: ELEC
100' - 0" AFF
FINISH FLOOR
116' - 6" AFF
T.O. STEEL
C1
A-301
PREFINISHED
STANDING SEAM
METAL ROOFING
PREFINISHED
METAL WALL PANEL
PREFINISHED METAL
DOWNSPOUT & CONCRETE
SPLASHBLOCK, TYP AT 4
CORNERS
OPEN
PREFINISHED METAL
GUTTER
EXHAUST; SEE
MECH
4" SPLIT FACE CMU
9'
10' - 0"
100' - 0" AFF
FINISH FLOOR
1 2 3 4
116' - 6" AFF
T.O. STEEL
C1
A-301PREFINISHED
STANDING SEAM
METAL ROOFING
PREFINISHED
METAL WALL PANEL
CONCRETE
SPLASHBLOCK, TYP
AT 4 CORNERS
PREFINISHED
METAL GUTTER &
DOWNSPOUT
OPEN4" SPLIT FACE
CMU
S101
100' - 0" AFF
FINISH FLOOR
ABCD
116' - 6" AFF
T.O. STEEL
PREFINISHED
METAL
GUTTER &
DOWNSPOUT
PREFINISHED
METAL WALL
PANEL
CONCRETE
SPLASHBLOCK
PREFINISHED
METAL TRIM AT
EDGE
W1 W1
102C 102D
4" GROUND
FACE CMU
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO DRAWING A-001.
SEE LOUVER AND WINDOW SCHEDULE DRAWING A-601 FOR
ADDITIONAL INFORMATION.
REFERENCE OVERALL ROOF PLAN FOR METAL DOWNSPOUT AND
GUTTER SIZING.
REFERENCE SHEET A-502 FOR PENETRATION DETAILS THRU FIRE
RATED CMU WALL.
PIPE SUPPORT PEDESTALS NOT SHOWN FOR CLARITY. REFER TO
STRUCT DWGS FOR LOCATION.
GENERAL NOTES: THIS DRAWING ONLY
1.
2.
3.
4.
5.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:2
A
M
FJRP159073-A-201.dwg
A-201
94893
EXTERIOR BUILDING ELEVATIONS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 1/8" = 1'-0"B3
WEST ELEVATION
SCALE: 1/8" = 1'-0"C1
NORTH ELEVATION
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
0 4' 8' 16'
SCALE: 1/8" = 1'-0"B1
SOUTH ELEVATION
SCALE: 1/8" = 1'-0"C3
EAST ELEVATION
* EXTERIOR MATERIAL LEGEND
DESCRIPTION MANUFACTURER /COLOR
MORTAR MATCH CMU
CONCRETE MASONRY UNITS (GROUND FACE) ADAMS: ECHELON OLDCASTLE 9364
CONCRETE MASONRY UNITS (SPLIT FACE) ADAMS: ECHELON OLDCASTLE 9364
METAL WALL / FASCIA / LINER PANELS COLOR MATCH TO CENTRIA 993 OFF-WHITE
METAL ROOF PANELS WHITE
STEEL DOORS AND DOOR FRAMES COLOR MATCH TO CENTRIA 993 OFF-WHITE
DOWNSPOUTS & GUTTERS COLOR MATCH TO CENTRIA 993 OFF-WHITE
LOUVERS COLOR MATCH TO CENTRIA 993 OFF-WHITE
* BASIS OF DESIGN OR EQUIVALENT
ABCD
116' - 6" AFF
T.O. STEEL
A1
A-311
PUMP ROOM
STANDING SEAM
METAL ROOF
GUTTER
4" GROUND FACE CMU
W1 W1
LIGHT FIXTURE; SEE ELEC
PREFINISHED METAL
WALL PANEL
A4
A-502
SIM
SIM
100' - 0" AFF
FINISH FLOOR
ABCD
116' - 6" AFF
T.O. STEEL
CONTROL ROOM
MECH ROOM
STANDING SEAM
METAL ROOF
GUTTER / DOWNSPOUT
B1
A-502
A4
A-502
SIM
A3
A-311
A3
A-311OPP SIM
HOLLOW METAL DOOR
AND FRAME
100' - 0" AFF
FINISH FLOOR
116' - 6" AFF
T.O. STEEL
C1
A-301
CONTROL ROOM
102PUMP ROOM
A2
A-311 A3
A-311 SIMSIM
LIGHT FIXTURE;
SEE ELEC
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO DRAWING A-001.
SEE LOUVER AND WINDOW SCHEDULE DRAWING A-601 FOR
ADDITIONAL INFORMATION.
REFERENCE OVERALL ROOF PLAN FOR METAL DOWNSPOUT AND
GUTTER SIZING.
REFERENCE SHEET A-502 FOR PENETRATION DETAILS THRU FIRE
RATED CMU WALL.
PIPE SUPPORT PEDESTALS NOT SHOWN FOR CLARITY. REFER TO
STRUCT DWGS FOR LOCATION.
GENERAL NOTES: THIS DRAWING ONLY
1.
2.
3.
4.
5.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:2
A
M
FJRP159073-A-301.dwg
A-301
94893
BUILDING SECTIONS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 1/8" = 1'-0"C1
BUILDING SECTION
SCALE: 1/8" = 1'-0"C3
BUILDING SECTION
SCALE: 1/8" = 1'-0"B1
BUILDING SECTION
0 4' 8' 16' 0 4' 8' 16'
0 4' 8' 16'
PREFINISHED
STANDING SEAM
METAL ROOF
STEEL STRUCTURE
PREFINISHED
METAL WALL
PANEL
CEILING AS
SCHEDULED
1" CONT POLYISO
INSULATION (R-5)
5/8" EXTERIOR GYPSUM
SHEATHING OVER 6" COLD-
FORMED METAL STUD
FLUID-APPLIED AIR
AND VAPOR BARRIER
4" SPLIT FACE
CMU
VAPOR BARRIER
FIBERGLASS BATT
INSULATION; R-19
WITH R-5 SPACER
BLOCKS AT PURLINS
WITH R-10 BETWEEN
PURLINS
CONTROL ROOM
FIBERGLASS BATT
INSULATION (R-13)
C2
A-502
B2
A-502
SIM
FIBERGLASS BATT
INSULATION; R-25
WITH R-0.375
THERMAL SPACER
BLOCK
WALL GIRT
5/8" MOISTURE RESISTANT
GWB
INTERIOR FURRING AT
LOCATIONS INDICATED
100' - 0" AFF
FINISH FLOOR
A
116' - 6" AFF
T.O. STEEL
PREFINISHED
METAL
GUTTER
PREFINISHED
METAL WALL
PANEL
WALL GIRT
EAVE STRUCTURE
SPLASHBLOCK
PREFINISHED
STANDING SEAM
METAL ROOFING
ROOF PURLIN
100' - 0" AFF
FINISH FLOOR
3 HR FIRE RATED
12" CMU WALL W/
VERT REINF; UL
U904
CEILING AS
SCHEDULED
WINDOW AS
SCHEDULED
FLUID-APPLIED AIR
AND VAPOR
BARRIER
BASE AS
SCHEDULED
1 1/2" CONT
POLYISO
INSULATION (R-7.6)
4" GROUND
FACE CMU
VAPOR BARRIER
PREFINISHED
METAL PANEL ON
Z-FURRING
INTERIOR
FURRING; SEE
PARTITION TYPES
COILING FIRE
SHUTTER AS
SCHEDULED
C1
A-502
B4
A-502
C4
A-502
FIBERGLASS BATT INSULATION;
R-19 WITH R-5 SPACER BLOCKS
AT PURLINS WITH R-10
BETWEEN PURLINS
PRECAST CONC
SILL
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND, AND
ABBREVIATIONS REFER TO DRAWING A-001.
SEE LOUVER AND WINDOW SCHEDULE DRAWING A-601 FOR
ADDITIONAL INFORMATION.
REFERENCE OVERALL ROOF PLAN FOR METAL DOWNSPOUT AND
GUTTER SIZING.
REFERENCE SHEET A-502 FOR PENETRATION DETAILS THRU FIRE
RATED CMU WALL.
PIPE SUPPORT PEDESTALS NOT SHOWN FOR CLARITY. REFER TO
STRUCT DWGS FOR LOCATION.
GENERAL NOTES: THIS DRAWING ONLY
1.
2.
3.
4.
5.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:2
A
M
FJRP159073-A-311.dwg
A-311
94893
WALL SECTIONS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 3/4" = 1'-0"A3
WALL SECTION
SCALE: 3/4" = 1'-0"A1
WALL SECTION
SCALE: 3/4" = 1'-0"A2
WALL SECTION
0 1' 2' 3' 0 1' 2' 3' 0 1' 2' 3'
A-401
C3
C4
B3
MEN'S/WOMEN'S
TOILET
M A
T C
H
LI
N E
: S E
E D
R A
W
IN
G A
-1
GB-1
GB-1
MG-1
ø 5' - 0" A
BA
1'
0"
P3
P2A
P1A
P2B
TTD-1
PTD-1
100' - 0" AFF
FINISH FLOOR
GB-1
TTD-1
INTEGRAL
RESILIENT
BASE, RB-3
FIBERGLASS
REINFORCED
PANEL, FRP-1
FRP TRIM
GB-1
100' - 0" AFF
FINISH FLOOR
MG-1
TRAP INSULATION
GB-1
TTD-1
INTEGRAL RESILIENT
BASE, RB-3
FIBERGLASS
REINFORCED PANEL,
FRP-1
FRP TRIM
PTD-1
100' - 0" AFF
FINISH FLOOR
PTD-1
INTEGRAL RESILIENT
BASE, RB-3
FIBERGLASS REINFORCED
PANEL, FRP-1
FRP TRIM
NOTE: PROVIDE BLOCKING FOR ALL TOILET ACCESSORIES AS NEEDED.
FFL
T O
IL
E
T P
A P
E R
D
IS
P E
N S
E R
P A
P E
R T
O W
E L
D
IS
P E
N S
E R
G
F G
I
" 40
(4 0"
M A
X
M
IR
R O
R A
B O
V E
L A
V A
T O
R Y
(1 5"
-4 8"
H E
IG
H
T M
O U
N T
IN
G
(A D
A R
E Q
U
IR
E D
R A
N G
E
F
IX
T U
R E
/E Q
U
IP
M E
N T
T Y
P E
ADA
COMPLIANT
INDICATOR
LEGEND
FFL
NOTE: FLUSH VALVE SHALL BE
LOCATED ON WIDE SIDE OF
STALLS
12" MIN.
36" MIN.
TOILET
PAPER
54" MIN.
42" MIN.
A
7.
M
IN
IC
C /A
N S
I
12" MAX.
TRANSFER
SIDE
39" - 41"
M
IN
7"- 9"
A B
A /A
D A
M
IN
24" MIN.
CLEAR
FLOOR
SPACE
48" MIN.
19" MAX.
17"-25"
M
IN
KNEE
CLEARANCE
8" MIN.
17" MIN.
11" MIN.
M A
X
B .O
. M
IR
R O
R
M A
X
M
IN
9" M
IN
6" MIN
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:3
A
M
FJRP159073-A-401.dwg
A-401
94893
ENLARGED TOILET PLAN & ELEVATIONS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 1/2" = 1'-0"C1
ENLARGED MEN'S/WOMEN'S TOILET
SCALE: 1/2" = 1'-0"C3
MEN'S/WOMEN'S TOILET
NORTH ELEVATION
SCALE: 1/2" = 1'-0"C4
MEN'S/WOMEN'S TOILET
WEST ELEVATION
0 1' 2' 4'
SCALE: 1/2" = 1'-0"B3
MEN'S/WOMEN'S TOILET
SOUTH ELEVATION
0 1' 2' 4'
0 1' 2' 4'
0 1' 2' 4'
NTSSCALE:A1
STANDARD ADA MOUNTING HEIGHTS
NTSSCALE:A3
GRAB BARS
NTSSCALE:B4
LAVATORIES
TOILET ACCESSORY SCHEDULE
TYPE DESCRIPTION
GB-1 PAIR OF GRAB BARS 36" LONG AND 42" LONG
MG-1 MIRROR - SURFACE MOUNTED, 24" X 36"
PTD-1 PAPER TOWEL DISPENSER; GFGI
TTD-1 TOILET TISSUE DISPENSER
N
TYPICAL PARTITION TYPES
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
SCHEDULED CEILING
HEAD
CEILING
PLAN
BASE
1 LAYER OF 5/8" TYPE "X"
GYPSUM BOARD EACH SIDE OF
3 5/8" METAL STUDS @ 16" O.C.
INSULATION
SEE BASE DETAIL B4/A-501
HEAD DETAIL PER
SCHEDULE BELOW
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
SCHEDULED CEILING
CEILING
PLAN
BASE
1 LAYER OF 5/8" MOISTURE
RESISTANT GYPSUM
BOARD ON 3 5/8" METAL
FURRING
FACE OF COLUMN, WALL,
OR SUBSTRATE
SEE BASE DETAIL A4/A-501
P3
SEE ROOM FINISH SCHEDULE
FOR FINISH MATERIALS OVER
GYPSUM BOARD
CEILING
PLAN
BASE
1 LAYER OF 5/8" GYPSUM BOARD
ON 3 5/8" METAL STUDS
SEE BASE DETAIL A4/A-501
METAL STUD BRACE @ 48" O.C. MAX.
EXTEND BRACE AND SECURE TO
ADJACENT STUD WALL
SCHEDULED CEILING
HEAD DETAIL PER
SCHEDULE BELOW
SEE HEAD DETAIL A3/A-501
INSULATION
GENERAL NOTES: PARTITION TYPES
WHERE STRUCTURAL MEMBERS PENETRATE FIRE-RATED CMU OR
CONCRETE WALLS, SEAL WITH FIRE STOPPING SEALANT.
PROVIDE MINIMUM 20 GAUGE METAL BACKING AS REQUIRED FOR
INSTALLATION OF EXTINGUISHER CABINETS, TOILET ACCESSORIES, ACCESS
PANELS, ELECTRICAL AND FIRE PROTECTION SYSTEM PANELS, UNLESS
NOTED OTHERWISE.
ALL METAL STUDS AND BRACING SHALL BE 20 GAUGE UNLESS NOTED
OTHERWISE. REFERENCE SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
REFERENCE DRAWING A-101 FOR PARTITION TYPE LOCATIONS.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT ALL RESTROOM WALLS
ON WET SIDE WALL.
PROVIDE MOISTURE RESISTANT GYPSUM BOARD AT INTERIOR SURFACE OF
ALL EXTERIOR WALLS.
1.
2.
3.
4.
5.
6.
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
5/8" GYPSUM BOARD ON
METAL STUDS OR METAL
FURRING, SEE FLOOR PLANS
FOR PARTITION TYPE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
RE: STRUCTURAL
EACH LAYER OF GYPSUM
BOARD SET IN CONTINUOUS
BEAD OF SEALANT (TYP.)
METAL BOTTOM
RUNNER SET IN
SEALANT
SCHEDULED BASE
RE: ROOM FINISH
SCHEDULE
5/8" GYPSUM BOARD ON
METAL STUDS @ 16" O.C.,
SEE FLOOR PLANS FOR
PARTITION TYPE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
FLOOR SLAB
RE: STRUCTURAL
EACH LAYER OF GYPSUM
BOARD SET IN CONTINUOUS
BEAD OF SEALANT (TYP.)
METAL BOTTOM RUNNER
SET IN SEALANT
GYPSUM BOARD ON
METAL STUDS, SEE
FLOOR PLANS FOR
PARTITION TYPE
SCHEDULED
CEILING
5/8" GYPSUM BOARD ON
METAL FURRING
UNDERSIDE FLOOR DECK
(METAL DECK OR CONC
SLAB)
6"
METAL STUD DIAGONAL
BRACING @ 4'-0" O.C.
(ALTERNATE DIRECTIONS) TO
UNDERSIDE OF METAL DECK
SCHEDULED CEILING
UNDERSIDE OF
METAL DECK OR
STRUCTURE ABOVE
6"
5/8" GYPSUM BOARD ON
METAL STUDS @ 16" O.C.
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:3
A
M
FJRP159073-A-501.dwg
A-501
94893
PARTITION TYPES
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
0 3" 6" 9"
SCALE: 3" = 1'-0"A4
INTERIOR PARTITION DETAILS
SCALE: 3" = 1'-0"B4
INTERIOR PARTITION DETAIL
SCALE: 3" = 1'-0"A3
INTERIOR PARTITION DETAIL
0 3" 6" 9"
0 3" 6" 9"
SCALE: 3" = 1'-0"B3
INTERIOR PARTITION DETAILS
0 3" 6" 9"
TYPE HEAD DETAIL
BASE
DETAIL TYPE COMMENTS
P1A B3/A-501 B4/A-501 3 5/8" METAL STUDS, PARTIAL HEIGHT WALL WITH
BLANKET INSULATION.
P1B B2/A-502 B4/A-501 3 5/8" METAL STUDS WITH BLANKET INSULATION.
TYPE HEAD DETAIL
BASE
DETAIL TYPE COMMENTS
P2A B3/A-501 SIM (GYP ONE SIDE ONLY) A4/A-501 3 5/8" METAL STUDS WITH BLANKET INSULATION.
P2B B3/A-501 SIM (GYP ONE SIDE ONLY) A4/A-501 3 5/8" METAL STUDS WITHOUT BLANKET INSULATION.
PANEL CLIP
STANDING SEAM METAL
ROOF
BEARING PLATE PER
ROOF INSTALLER
CONTINUOUS CLEAT
RIVET
FIELD PAN PANEL ENDS AS REQUIRED
WEBBED MASTIC
FOAM AND METAL
CLOSURE
RIDGE
FLASHING
MYLAR COATED TAPE
WEBBED MASTIC
ROOF PURLIN
RE: STRUCTURAL INTERIOR RIDGE TRIM AND
CONT INSULATION
BENT PLATE W/ VERTICAL
SLOT WELD TO ROOF
PURLIN AT VERTICAL
STUDS
STANDING SEAM
METAL ROOF
ROOF PURLIN
FIBERGLASS BATT
INSULATION
PARTITION TYPE
AS INDICATED
VERIFY DIMENSION BY
DISTANCE BETWEEN
FACE OF GWB TO
ROOF PURLIN 16" MAX.
3/
4"
4"
3 HR FIRE RATED 12" CMU W/
VERT REINF; GROUT SOLID
ALL CELLS; UL U904
STL ANGLE; SEE STRUCT
CUT BLOCK FILL W/ GROUT
CMU BOND BEAM
RIGID INSULATION
PREFINISHED METAL PANEL
ON Z-FURRING
PREFINISHED STANDING
SEAM METAL ROOF
FLUID-APPLIED AIR / VAPOR
BARRIER
THE DISTANCE BETWEEN THE TOP OF
WALL AND METAL DECK SHALL NOT
BE LESS THAN A 1/2 INCH OR
GREATER THAN 2 INCHES
PROVIDE 3 HOUR
FIRE STOPPING
ASSEMBLY SIMILAR
TO UL HW-D-0403
FILL VOID WITH MIN 4 PCF MINERAL
WOOL BATT INSULATION
COMPRESSED TO 50%
MINIMUM 1/2" THICK FLEXIBLE
FIRESTOP SEALANT BOTH SIDES
OF JOINT
1" CONT POLYISO INSULATION (R-5)
5/8" EXTERIOR GYPSUM SHEATHING
OVER 6" METAL STUD
FLUID-APPLIED AIR AND VAPOR BARRIER
4" SPLIT FACE CMU
FIBERGLASS BATT INSULATION (R-13)
PREFINISHED METAL WALL PANEL
WALL GIRT
CLOSURE STRIP
5/8" GYPSUM
BOARD
PREFINISHED "J" TRIM
SEALANT
PREFINISHED METAL FLASHING
TO MATCH METAL WALL PANELS
THERMAL SPACER BLOCK
1" CONT POLYISO INSULATION (R-5)
5/8" EXTERIOR
GYPSUM SHEATHING
OVER 6" METAL
STUD
FLUID-APPLIED AIR AND VAPOR
BARRIER
4" SPLIT FACE CMU
FIBERGLASS BATT
INSULATION (R-13)
5/8" GYPSUM
BOARD
CONCRETE SLAB; RE:
STRUCTURAL THRU-WALL FLASHING, EXTEND
MIN 8" VERTICAL ABOVE CAVITY
DRAINAGE MATERIAL
FLASHING TERMINATION
BAR WITH FASTENERS
CAVITY DRAINAGE MATERIAL
VENTED WEEPS @ 32" O.C.
3 HR RATED 12"
CMU WALL W/
VERT REINF;
GROUT SOLID
FLUID-APPLIED AIR AND
VAPOR BARRIER
BASE AS
SCHEDULED
1 1/2" CONT POLYISO
INSULATION (R-7.6)
4" GROUND FACE CMU
INTERIOR
FURRING; SEE
PARTITION TYPES
THRU-WALL FLASHING,
EXTEND MIN 8" VERTICAL
ABOVE CAVITY DRAINAGE
MATERIAL
VENTED WEEPS @
32" O.C.
CAVITY DRAINAGE
MATERIAL
FLASHING TERMINATION
BAR WITH FASTENERS
PREFINISHED METAL
WALL PANEL
CLOSURE STRIP
PREFINISHED
"J" TRIM
SEALANT
PREFINISHED METAL
FLASHING
FLUID-APPLIED AIR AND
VAPOR BARRIER
1 1/2" CONT POLYISO
INSULATION (R-7.6)
4" GROUND FACE CMU
3 HR RATED 12" CMU
W/ VERT REINF;
GROUT SOLID
METAL ROOFING
FILL SPACE ALL AROUND
STRUCTURAL MEMBER
WITH FIRESTOP SYSTEM
(UL SYSTEM NO. EQUAL
TO C-AJ-8210 OR C-
AJ-1022 FOR PIPE.)
SHEET METAL
FLASHING
CMU WALL
ROOF PURLIN
ROOF PURLIN THROUGH MASONRY
WALL
2" M
IN
D E
P T
H
P U
R
LI
N
1"
WIDTH
PURLIN 1"
FIRESTOP SEALANT
ALL AROUND BOTH
SIDES
(3 HOUR RATING) EQUAL TO UL SYSTEM
NUMBER W-J-1040 PIPE OR CONDUIT
PENETRATING CMU WALL w/o STEEL
SLEEVE DETAIL
CMU WALL
RE: WALL SECTIONS
FOR TYPE
MECHANICAL PIPE OR
ELECTRICAL CONDUIT
RE: MECH. AND ELEC. DWGS
FOR LOCATIONS AND SIZES
FIRESTOP SEALANT,
BOTH SIDES; MIN 1/2"
DIA BEAD AT CONTACT
POINT
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:3
A
M
FJRP159073-A-502.dwg
A-502
94893
DETAILS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
P. GREGORY
SCALE: 1 1/2" = 1'-0"A4
RIDGE DETAIL
0 1/2' 1' 1 1/2'
SCALE: 1" = 1'-0"B1
HEAD DETAIL AT METAL STUD WALL
0 1/2' 1' 2'
SCALE: 1 1/2" = 1'-0"C1
HEAD DETAIL AT CMU WALL
0 1/2' 1' 1 1/2'
SCALE: 3" = 1'-0"C2
METAL PANEL AT STUD WALL DETAIL
0 3" 6" 9"
SCALE: 3" = 1'-0"B2
STUD WALL BASE DETAIL
0 3" 6" 9"
SCALE: 3" = 1'-0"B4
CMU WALL BASE DETAIL
SCALE: 3" = 1'-0"C4
METAL PANEL AT CMU WALL DETAIL
0 3" 6" 9"
0 3" 6" 9"
NTSSCALE:A1
ROOF PURLIN THROUGH CMU DETAIL
NTSSCALE:A2
PIPE THROUGH CMU DETAIL
2"
SCHEDULE
DOOR PER 2"
4"
S C
H E
D U
LE
D O
O R
P E
R
2"
SCHEDULE
DOOR PER 2"
2"
S C
H E
D U
LE
D O
O R
P E
R
1.1 1.2NL-IN
D O
O R
P E
R S
C H
E D
U
LE
SCHEDULE
DOOR PER
D O
O R
P E
R S
C H
E D
U
LE
2'
1"
6"
6" 8"
SCHEDULE
DOOR PER
F
F-IN OH-S
S C
H E
D U
LE
D O
O R
P E
R
SCHEDULE
DOOR PER
3'
4'
3' - 4"
W1
2" TYP.
GLASS TYPES:
REFERENCE SPECIFICATION FOR GLASS TYPES
1 LOW-E INSULATED SAFETY GLAZING (1")
2 INSULATED LAMINATED (1")
GENERAL NOTES: ROOM FINISH SCHEDULE
REFER TO SPECIFICATIONS FOR THE BASIS OF DESIGN OR
EQUIVALENT MANUFACTURER TECHNICAL REQUIREMENTS.
REFER TO INTERIOR ELEVATIONS, REFLECTED CEILING
DRAWINGS, AND ENLARGED PLAN DRAWINGS FOR ADDITIONAL
FINISH PLACEMENT INFORMATION.
REFER TO ELECTRICAL DRAWINGS, MECHANICAL DRAWINGS,
STRUCTURAL DRAWINGS AND COMMUNICATION DRAWINGS
FOR COORDINATION OF BUILDING FINISHES TO BUILDING
SYSTEMS.
REFER TO REFLECTED CEILING DRAWINGS FOR CEILING
HEIGHTS AND CEILING MATERIAL EXTENTS.
PROVIDE BLOCKING AS REQUIRED TO SECURE ALL WALL
MOUNTED ITEMS INCLUDING TOILET FIXTURES, TOILET
ACCESSORIES, MILLWORK, AND ANY OTHER WALL MOUNTED
OBJECT.
UNLESS NOTED OTHERWISE, ALL EXPOSED STRUCTURAL
STEEL TO BE PAINTED PE-1.
1.
2.
3.
4.
5.
6.
ALL INTERIOR DOORS/FRAMES AND INTERIOR SURFACE OF
EXTERIOR DOORS/FRAMES TO BE PA-2.
INTERIOR CAULKING TO MATCH ADJACENT WALL FINISH COLOR.
ALL EXPOSED CONCRETE FLOORS SHALL BE SEALED.
PAINT ALL EXPOSED STRUCTURAL STEEL ELEMENTS,
MISCELLANEOUS STEEL, PIPING, HANGERS, VALVES AND CONDUITS
EXCEPT PRE-FINISHED LINER PANELS AND FOAM GENERATORS.
THE PAINT COLOR SHALL BE AS INDICATED ON SCHEDULE. ALL FIRE
PROTECTION PIPING COLOR SHALL BE SAFETY RED.
ALL EXPOSED MECHANICAL AND ELECTRICAL EQUIPMENT AND
ASSOCIATED SUPPORTING EQUIPMENT TO BE PAINTED TO MATCH
ADJOINING SURFACE UNLESS OTHERWISE REQUIRED BY CODE.
COORDINATE WITH MECHANICAL / ELECTRICAL FOR FINISHES ON
MECHANICAL OR ELECTRICAL EQUIPMENT.
DO NOT PAINT PRE-FINISHED ITEMS, FINISHED METAL SURFACES,
OPERATING PARTS, LABELS OR WARNINGS.
7.
8.
9.
10.
11.
12.
GENERAL NOTES: THIS SHEET ONLY
DIMENSIONS GIVEN IN DOOR, WINDOW AND LOUVER
SIZE COLUMN ARE FINISHED OPENING DIMENSIONS.
REFERENCE DRAWING A-611 FOR EXTERIOR DOOR,
WINDOW AND LOUVER DETAILS.
1.
2.
DOOR FRAME
RE: DOOR
SCHEDULE
DOOR
RE: DOOR SCHEDULE
FINISH FLOOR
RE: ROOM FINISH
SCHEDULE
SEALANT
D O
O R
H E
IG
H
T S
E E
D O
O R
S C
H E
D U
LE
FRAME WIDTH
SEALANT TYP.
BOTH SIDES
DOOR FRAME
RE: SCHEDULE
DOOR
RE: DOOR SCHEDULE
BATT INSULATION
2" D
O O
R W
ID
T
H S
E E
D O
O R
S C
H E
D U
LE
JAMB ANCHORS
3 PER JAMB MIN.
1/2" 1/2"
FRAME WIDTH
METAL STUD WALL
RE: FLOOR PLANS FOR
WALL TYPE
SEALANT TYP. BOTH
SIDES
DOOR FRAME
RE: DOOR SCHEDULE
DOOR
RE: DOOR SCHEDULE
METAL STUD WALL
RE: FLOOR PLANS FOR
WALL TYPE
BATT INSULATION
1/2"1/2"
2" D
O O
R H
E
IG
H T
S E
E D
O O
R S
C H
E D
U
LE
FRAME WIDTH
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:3
A
M
FJRP159073-A-601.dwg
A-601
94893
DOOR, WINDOW, LOUVER & ROOM FINISH
SCHEDULES
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
DOOR SCHEDULE
DOOR
NUMBER
DOOR FRAME
ASSEMBLY
RATING
DETAIL
HARDWARE
SET REMARKS
SIZE
TYPE MATERIAL FINISH TYPE MATERIAL FINISH HEAD JAMB SILLWIDTH HEIGHT
102A PR. 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 1.0
102B - 3' - 0" 7' - 0" NL-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 2.0
102C - 3' - 4" 4' - 10" OH-S STL PREFIN STL PREFIN 3 HR C2/A-611 B2/A-611 A2/A-611 - 1
102D - 3' - 4" 4' - 10" OH-S STL PREFIN STL PREFIN 3 HR C2/A-611 B2/A-611 A2/A-611 - 1
103 - 3' - 0" 7' - 0" F HM PE-1 1.1 HM PE-1 - B2/A-601 B3/A-601 B5/A-601 3.0
104 PR. 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 4.0
105 - 3' - 0" 7' - 0" F-IN HM PE-1 1.2 HM PE-1 - C1/A-611 B1/A-611 A1/A-611 5.0
DOOR AND FRAME LEGEND
FINISH
FINISH PE-1* PAINT-EPOXY
FINISH PREFIN PREFINISHED
MATERIAL
MATERIAL HM HOLLOW METAL
SIZE
SIZE - SINGLE DOOR
SIZE PR PAIR OF DOORS
TYPE
TYPE F FLUSH
TYPE F-IN FLUSH INSULATED
TYPE NL-IN NARROW LITE INSULATED
TYPE OH-S COILING FIRE SHUTTER
* FIELD APPLY PER PAINT SPECIFICATION FOR APPLICABLE
SUBSTRATE AND EXPOSURE.
WINDOW SCHEDULE
QUANTITY TYPE
SIZE SILL
HEIGHT
DETAIL
WIDTH HEIGHT HEAD JAMB SILL
2 W1 3' - 4" 4' - 0" 3' - 4" C3/A-611 B3/A-611 A3/A-611
LOUVER SCHEDULE
QUANTITY TYPE
SIZE SILL
HEIGHT
DETAILS
WIDTH HEIGHT HEAD JAMB SILL
1 L1 3' - 0" 2' - 0" 8' - 0" C4/A-611 B4/A-611 A4/A-611
NTSSCALE:C2
FRAME TYPES
NTSSCALE:C1
DOOR TYPES
SCALE: 1/4" = 1'-0"
WINDOW TYPE
0 2' 4' 8'
FINISH LEGEND - BASIS OF DESIGN OR EQUIVALENT
MATERIAL DESCRIPTION MANUF.
MODEL
NUMBER
PRODUCT
NUMBER COLOR REMARKS
BASE
RB-1 RESILIENT RUBBER BASE, 4" HIGH ROPPE - - DARK GRAY 150 STANDARD TOE PROFILE
RB-2 INTEGRAL RESILIENT RUBBER BASE,
4" HIGH
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD INTEGRAL TO RESILIENT SHEET
FLOORING
RB-3 INTEGRAL RESILIENT RUBBER BASE,
6" HIGH
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD INTEGRAL TO RESILIENT SHEET
FLOORING
CEILINGS
ACT-1 ACOUSTICAL CEILING TILE, 24" x 24" ARMSTRONG CIRRUS
TEGULAR
584 WHITE
EXP EXPOSED - - - - PAINT PE-1
GWB GYPSUM WALL BOARD - - - - PAINT PE-1
MR GWB MOISTURE RESISTANT GYPSUM
WALL BOARD
- - - - PAINT PE-1
PE-1 PAINT - EPOXY - CEILING SHERWIN WILLIAMS - - WHITE
FLOORING
CS-1 CONCRETE - SEALED - - - -
PE-2 EPOXY - HIGH PERFORMANCE
COATING
- - - - SLIP-RESISTANT
RF-1 RESILIENT FLOORING -
HOMOGENEOUS VINYL SHEET
JOHNSONITE IQ OPTIMA - 853 THUNDERHEAD
WALLS
FRP-1 FIBERGLASS REINFORCED PANEL MARLITE INDURO FRP - D381 FASHION GREY
PA-1 PAINT SHERWIN WILLIAMS - - AGREEABLE GRAY
SW7029
PA-2 PAINT SHERWIN WILLIAMS - - DOVETAIL SW7018 METAL DOORS & FRAMES
ROOM FINISH SCHEDULE
ROOM
NUMBER ROOM NAME FLOOR
BASE WALLS
CEILINGMATERIAL NORTH EAST SOUTH WEST
101 PUMP ROOM PE-2 - - - - - EXP
102 CONTROL ROOM RF-1 RB-2 PA-1 PA-1 PA-1 PA-1 ACT-1
103 MEN'S/WOMEN'S TOILET RF-1 RB-3 FRP-1 FRP-1 FRP-1 FRP-1 MR GWB
104 MECH ROOM CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 EXP
105 STORAGE CS-1 RB-1 PA-1 PA-1 PA-1 PA-1 GWB
B1
0 3" 6" 9"SCALE: 3" = 1'-0"B5
DOOR SILL
SCALE: 3" = 1'-0"B3
DOOR JAMB
SCALE: 3" = 1'-0"B2
DOOR HEAD
0 3" 6" 9"0 3" 6" 9"
1. MANUALLY OPERATED COILING FIRE SHUTTER W/ FUSIBLE
LINK BOTH SIDES OF WALL. LOCATE FUSIBLE LINK 12 INCHES
FROM THE CEILING.
DOOR SCHEDULE REMARKS:
RIGID INSULATION
6" METAL STUDS
HM FRAME,
GROUT SOLID
CONTINUOUS
VAPOR BARRIER
CONTINUOUS
SEALANT WITH
BACKER ROD, BOTH
SIDES
4" SPLIT FACE
CMU
MTL FLASHING
CONT. GALV
STEEL ANGLE
PAINT TO
MATCH DOOR
FRAME
5/8" GYPSUM
BOARD
1" AIR SPACE
5/8" GYPSUM
SHEATHING
FLASHING
TERMINATION BAR
WITH FASTENERS
MORTAR NET
WEEPS @ 32" O.C.
DOOR FRAME
RE: DOOR
SCHEDULE
DOOR
RE: DOOR
SCHEDULE
SEALANT TYP.
BOTH SIDES
GROUT JAMB FULL
FRAME WIDTH
RIGID INSULATION
6" METAL STUDS
CONTINUOUS
VAPOR BARRIER
4" SPLIT FACE
CMU
1" AIR SPACE
5/8" GYPSUM
BOARD
5/8" GYPSUM
SHEATHING
SEE WINDOW
SCHEDULE
SEALANT TYP.
BOTH SIDES
CMU WALL
RE: STRUCTURAL
FOR REINFORCING
RIGID INSULATION
CONTINUOUS VAPOR
BARRIER
4" SPLIT FACE CMU
REINFORCED
PRECAST CONCRETE
SILL BELOW
OVERHEAD
COILING DOOR
AND TRACK
PRECAST SILL
PROVIDE
BULLNOSE
CORNER
PAINT CMU TO
MATCH WALL
RIGID INSULATION
8" CMU BOND
BEAMS
SEE WINDOW SCHEDULE
CONT VAPOR
BARRIER
CONTINUOUS SEALANT WITH
BACKER ROD, BOTH SIDES
4" GROUND FACE
CMU
CONT. GALV.
STEEL ANGLE
PAINT TO MATCH
WINDOW FRAME
MORTAR NET
WEEPS @ 32" O.C.
OVERHEAD COILING
DOOR HOOD, VERIFY
INSTALLATION W/
DOOR MANUF'S
WARRANTY AND
RECOMMENDATIONS
FOR ATTACHMENT
PAINT CMU TO MATCH
INTERIOR WALL
RIGID INSULATION
SEE WINDOW SCHEDULE
CONT VAPOR
BARRIER
4" SPLIT FACE CMU
CONT. JOINT SEALANT AND
BACKING, TYP.
SHIM AS REQUIRED
PRECAST
CONCRETE SILL
1" AIR SPACE
OVERHEAD COILING
DOOR
CONT GALV STL
ANGLE
THRU WALL
METAL
FLASHING
5"
REINFORCED PRECAST
CONCRETE SILL; 3 HR
FIRE RATING BASED ON
IBC TABLE 721.1(2) ITEM
4-1.1; PAINT TO MATCH
WALL
5/
8"
RIGID INSULATION
6" METAL STUDS
CONTINUOUS
VAPOR BARRIER
CONTINUOUS
SEALANT WITH
BACKER ROD, BOTH
SIDES
4" SPLIT FACE
CMU
MTL FLASHING
CONT. GALV
STEEL ANGLE
PAINT TO
MATCH DOOR
FRAME
5/8" GYPSUM
BOARD
1" AIR SPACE
5/8" GYPSUM
SHEATHING
4" LONG ALUMINUM
CLIP ANGLES WITH
SELF-DRILLING
SCREWS (2 PER CLIP
AT 18" O.C MAX.
ALUMINUM LOUVER
BIRD SCREEN
FLASHING
TERMINATION BAR
WITH FASTENERS
WEEPS @ 32" O.C.
MORTAR NET
SEALANT TYP.
BOTH SIDES
RIGID INSULATION
6" METAL STUDS
CONTINUOUS
VAPOR BARRIER
4" SPLIT FACE
CMU
1" AIR SPACE
5/8" GYPSUM
BOARD
5/8" GYPSUM
SHEATHING
CONTINUOUS
SEALANT WITH
BACKER ROD, BOTH
SIDES
4" LONG ALUMINUM
CLIP ANGLES WITH
SELF-DRILLING
SCREWS (2 PER CLIP
AT 18" O.C MAX.
ALUMINUM LOUVER
BIRD SCREEN
RIGID INSULATION
6" METAL STUDS
CONTINUOUS
VAPOR BARRIER
CONTINUOUS
SEALANT WITH
BACKER ROD, BOTH
SIDES
4" SPLIT FACE CMU
CONT. GALV
STEEL ANGLE
5/8" GYPSUM
BOARD
1" AIR SPACE
3/4" PLYWOOD
SHEATHING
4" LONG ALUMINUM
CLIP ANGLES WITH
SELF-DRILLING
SCREWS (2 PER CLIP
AT 18" O.C MAX. FLASHING
WALL BEYOND
SEE DOOR
SCHEDULE
CONCRETE
STOOP
FINISH FLOOR -
SEE ROOM FINISH
SCHEDULE
METAL
THRESHOLD
CMU WALL
BEYOND
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:4
A
M
FJRP159073-A-611.dwg
A-611
94893
DOOR, WINDOW & LOUVER DETAILS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
SCALE: 3" = 1'-0"C1
DOOR HEAD
SCALE: 3" = 1'-0"B1
DOOR JAMB
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
0 3" 6" 9"
SCALE: 3" = 1'-0"B2
WINDOW JAMB
SCALE: 3" = 1'-0"C2
WINDOW HEAD
SCALE: 3" = 1'-0"A2
WINDOW SILL
SCALE: 3" = 1'-0"C4
LOUVER HEAD
SCALE: 3" = 1'-0"B4
LOUVER JAMB
SCALE: 3" = 1'-0"A4
LOUVER SILL
SCALE: 3" = 1'-0"A1
DOOR SILL
4' -0
T
O
'-0
BASE LINE OF HIGHEST COPY MOUNTED
NO HIGHER THAN 60" AFF
BASELINE OF LOWEST COPY MOUNTED
NO LOWER THAN 48" AFF
MOUNT SIGN ON LATCH SIDE OF DOOR
MIN. TO CENTER
9"
4' -0
T
O
'-0
EQ EQ
E Q
E Q
BASE LINE OF HIGHEST COPY MOUNTED
NO HIGHER THAN 60" AFF,
BASELINE OF LOWEST COPY MOUNTED
NO LOWER THAN 48" AFF
MOUNT SIGN ON CENTER OF DOOR.
MECHANICAL
ROOM
6"
6"
PERMANENT TEXT 1 1/4"
HIGH HELVETICA NEUE
65 MEDIUM & BRAILLE;
SEE SCHEDULE FOR
MESSAGE AND NUMBER
EXTERIOR GRADE
PREFINISHED SIGN
SUBSTRATE
NO SMOKING WITHIN
25' OF BUILDING
6"
6"
PERMANENT TEXT
HELVETICA NEUE 65
MEDIUM
EXTERIOR GRADE
PREFINISHED
ALUMINUM SIGN
SUBSTRATE
GENERAL NOTES: SIGNAGE
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
REFER TO SIGNAGE PLAN FOR LOCATION OF INTERIOR AND
EXTERIOR SIGNAGE.
REFER TO SIGNAGE DETAILS FOR SIGNAGE CONSTRUCTION
AND MOUNTING ELEVATION.
REFER TO ARCHITECTURAL DRAWINGS FOR COORDINATION
OF SIGNAGE INSTALLATION TO WALL CONSTRUCTION.
SIGNAGE MUST BE ANCHORED THRU THE SURFACE APPLIED
WALL FINISHES TO THE SUBSTRATE WALL.
ALL HARDWARE/MOUNTING ATTACHMENTS TO BE CONCEALED
AND APPROPRIATE FOR THE RECEIVING BUILDING SURFACE.
ALL SIGNAGE SHALL COMPLY WITH THE MOST CURRENT
VERSION OF THE AMERICANS WITH DISABILITIES ACT (ADA).
INSTALL FIRE EXTINGUISHER IDENTIFICATION SIGN ABOVE ALL
FIRE EXTINGUISHER CABINETS AND WALL BRACKET MOUNTED
EXTINGUISHERS. SEE LIFE SAFETY PLANS FOR FIRE
EXTINGUISHER LOCATIONS.
CONSTRUCT EXTERIOR GRADE SIGNAGE WITH MATERIAL
APPROPRIATE FOR EXTERIOR USAGE.
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATING WITH SIGNAGE MANUFACTURER(S) TO
PROVIDE ANY ADDITIONAL SIGNAGE AS REQUIRED BY
GOVERNING MUNICIPALITY AT THE SITE LOCATION.
ALL MESSAGE TEXT AS SHOWN ON THE SIGN SCHEDULE IS A
PLACE HOLDER ONLY AND IS NOT THE FINAL TEXT MESSAGE.
ALL MESSAGE TEXT SHALL BE CONFIRMED BY GOVERNMENT
END USER PRIOR TO SIGNAGE SHOP DRAWINGS. ALLOW FOR
MAXIMUM 4 DIGIT ROOM NUMBERS AND MINIMUM 25
CHARACTER ROOM NAMES TYPICAL FOR ALL SIGNS.
PROVIDE EXTERIOR BUILDING NUMBER SIGN PER BASE
STANDARDS AND IN ACCORDANCE WITH SIGN STANDARDS
UFC 3-120-1.
A
2 3 4
B
C
D
CONTROL ROOM
PUMP ROOM
MECH ROOM
MEN'S/WOMEN'S
TOILET
STORAGE
S102A
S102B
S105A
S104
S102C
S103
S105B
S101
SEE ELEVATIONS
6"
8"
3/4" HIGH PERMANENT
RAISED TEXT & BRAILLE
3/8" THICK MATTE ACRYLIC
BACKGROUND
4" PICTOGRAM BASED ON SIGN
LOCATION. WHITE PICTOGRAM.
RESTROOM
1' - 0"
1'
1" TYP.
10" HIGH PERMANENT TEXT
HELVETICA NEUE 65 MEDIUM
EXTERIOR GRADE
PREFINISHED ALUMINUM
SIGN SUBSTRATE
NO CHEMICAL OR
USED FILTER
STORAGE
ALLOWED IN THIS
AREA
6"
6"
PERMANENT TEXT
HELVETICA NEUE 65
MEDIUM
EXTERIOR GRADE
PREFINISHED SIGN
SUBSTRATE
date detailed checkeddesigned ofsheet sheets project contract rev.drawing file
DESCRIPTION
1 5432
A
B
C
D
C O
P Y
R
IG
H T
R
N S
M
C D
O N
N E
L L E
N G
IN
E
E R
IN
G
C O
M P
A N
Y
IN
C
C-17 TYPE III HYDRANT
REFUELING SYSTEM/
RAMP EXPANSION
KANSAS CITY, MISSOURI
INITDATEREV.
REVISIONS
ENGINEERS ARCHITECTS & CONSULTANTS
NORTH CAROLINA AIR NATIONAL GUARD
DOUGLAS INTERNATIONAL AIRPORT
CHARLOTTE, NORTH CAROLINA
Project No. - FJRP159073
/6
/2
:0
:4
A
M
FJRP159073-A-701.dwg
A-701
94893
SIGNAGE SCHEDULE & DETAILS
OCTOBER 2017
L. SUNDERLAND E. VELAZQUEZ
A. CANTORIA
NTSSCALE:D1
TYPICAL SIGN INSTALLATION -TYPE 1
NTSSCALE:D2
SIGN INSTALLATION - TYPE 2
SCALE: 6" = 1'-0"D3
SIGN TYPE A
SCALE: 6" = 1'-0"C2
SIGN TYPE C
SIGNAGE SCHEDULE
SIGN TAG SIGN TYPE
SIGNAGE MESSAGE
SIGN INSTALLATION (SEE
DETAILS D1 & D2/A-701)
ROOM
NUMBER TEXT
S101 D - - SEE BUILDING ELEVATION
S102A A 102 CONTROL ROOM TYPE 1
S102B A 102 CONTROL ROOM TYPE 1
S102C C - - TYPE 2
S103 B - RESTROOM TYPE 1
S104 A 104 MECHANICAL ROOM TYPE 1
S105A A 105 STORAGE ROOM TYPE 1
S105B E - - TYPE 2
SCALE: 1/8" = 1'-0"A1
SIGNAGE PLAN
0 4' 8' 16'
N
SCALE: 6" = 1'-0"C1
SIGN TYPE B
0 1" 2" 4"3" 0 1" 2" 4"3"
0 1" 2" 4"3"
SCALE: 3" = 1'-0"C3
SIGN TYPE D
0 3" 6" 9"
SCALE: 6" = 1'-0"A3
SIGN TYPE E
0 3" 6" 9"
| A-001 - ARCHITECTURAL LEGEND & ABBREVIATIONS |
| A-101 - FLOOR PLAN |
| A-102 - REFLECTED CEILING PLAN & ROOF PLAN |
| A-201 - EXTERIOR BUILDING ELEVATIONS |
| A-301 - BUILDING SECTIONS |
| A-311 - WALL SECTIONS |
| A-401 - ENLARGED TOILET PLAN & ELEVATIONS |
| A-501 - PARTITION TYPES |
| A-502 - DETAILS |
| A-601 - DOOR, WINDOW, LOUVER & ROOM FINISH SCHEDULES |
| A-611 - DOOR, WINDOW & LOUVER DETAILS |
| A-701 - SIGNAGE SCHEDULE & DETAILS |
File details come from the government source that posted it.