This is a Contract Line Item Number (CLIN) schedule for water testing services at Success Lake for the U.S. Army Corps of Engineers Sacramento District. The document covers a multi-year contract from June 2025 to May 2030 (4 option years), detailing monthly water testing requirements across multiple locations including Tule Day Use Pump Houses, Rocky Hill Day Use Area, Administration Area Pump House, and Tule Oxidation Pond.
The water testing schedule includes consistent monthly testing for coliform (5 tests per month), nitrates, dissolved oxygen, field pH, electrical conductivity, and an annual test for formaldehyde, zinc, phenol, and nitrogen. The contract allows for up to 48 coliform retests and 24 trip fees per contract year. Each year's testing protocol remains identical, with line item numbers incrementing (0001, 1001, 2001, 3001, 4001) to denote successive option years. The testing sites are located near Porterville, California, with the primary objective of monitoring water quality at Success Lake.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Base
| Base Year: 01 June 2025 - 31 May 2026 | |||||||
| P/A | QT 100 | FC | |||||
| Water Testing | Amount of Contract | $ - 0 | |||||
| Month | Line Item | Description | Qty | Total Used to Date | $ - 0 |
| Jun-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | TOTAL LEFT IN CONTRACT | $ - 0 | ||||||
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Description | Line Items | Max Amt | Qty Used | Qty left | Line Item Price | Total | |||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||||||||||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||||||||||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | P/A | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | QT 100 | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | Field Chlorine | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | Coliform Retest | 0001AB | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| 0001AF | Trip Fee | Not to exceed 24 in contract year | Nitrates | 0001AC | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| Dissolved Oxygen | 0001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||||
| Jul-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | Field pH | 0001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Electrical Conductivity (EC) | 0001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | Formaldehyde, Zinc, Phenol, Nitrogen | 0001AE | 1 | 0 | 1 | $ - 0 | $ - 0 | |||
| 0001AA | Coliform x 1 - Administration Area Pump House | Trip Fee | 0001AF | 24 | 0 | 24 | $ - 0 | $ - 0 | |||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | $ - 0 | ||||||||
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |||||||||
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |||||||||
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Aug-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Sep-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Oct-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Nov-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Dec-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Jan-26 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Feb-25 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Mar-26 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| Apr-26 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
| May-26 | 0001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 0001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 0001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 0001AA | Coliform x 1 - Administration Area Pump House | ||
| 0001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 0001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 0001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 0001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 0001AF | Trip Fee | Not to exceed 24 in contract year |
OY1
| OY1: 01 June 2026 - 31 May 2027 | |||||||
| P/A | QT 100 | FC | |||||
| Water Testing | Amount of Contract | $ - 0 | |||||
| Month | Line Item | Description | Qty | Total Used to Date | $ - 0 |
| Jun-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | TOTAL LEFT IN CONTRACT | $ - 0 | ||||||
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Description | Line Items | Max Amt | Qty Used | Qty left | Line Item Price | Total | |||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||||||||||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||||||||||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | P/A | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | QT 100 | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | Field Chlorine | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | Coliform Retest | 1001AB | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| 1001AF | Trip Fee | Not to exceed 24 in contract year | Nitrates | 1001AC | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| Dissolved Oxygen | 1001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||||
| Jul-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | Field pH | 1001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Electrical Conductivity (EC) | 1001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | Formaldehyde, Zinc, Phenol, Nitrogen | 1001AE | 1 | 0 | 1 | $ - 0 | $ - 0 | |||
| 1001AA | Coliform x 1 - Administration Area Pump House | Trip Fee | 1001AF | 24 | 0 | 24 | $ - 0 | $ - 0 | |||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | $ - 0 | ||||||||
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |||||||||
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |||||||||
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Aug-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Sep-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Oct-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Nov-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Dec-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Jan-26 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Feb-25 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Mar-26 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| Apr-26 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
| May-26 | 1001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 1001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 1001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 1001AA | Coliform x 1 - Administration Area Pump House | ||
| 1001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 1001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 1001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 1001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 1001AF | Trip Fee | Not to exceed 24 in contract year |
OY2
| OY2: 01 June 2027 - 31 May 2028 | |||||||
| P/A | QT 100 | FC | |||||
| Water Testing | Amount of Contract | $ - 0 | |||||
| Month | Line Item | Description | Qty | Total Used to Date | $ - 0 |
| Jun-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | TOTAL LEFT IN CONTRACT | $ - 0 | ||||||
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Description | Line Items | Max Amt | Qty Used | Qty left | Line Item Price | Total | |||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||||||||||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||||||||||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | P/A | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | QT 100 | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | Field Chlorine | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | Coliform Retest | 2001AB | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| 2001AF | Trip Fee | Not to exceed 24 in contract year | Nitrates | 2001AC | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| Dissolved Oxygen | 2001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||||
| Jul-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | Field pH | 2001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Electrical Conductivity (EC) | 2001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | Formaldehyde, Zinc, Phenol, Nitrogen | 2001AE | 1 | 0 | 1 | $ - 0 | $ - 0 | |||
| 2001AA | Coliform x 1 - Administration Area Pump House | Trip Fee | 2001AF | 24 | 0 | 24 | $ - 0 | $ - 0 | |||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | $ - 0 | ||||||||
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |||||||||
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |||||||||
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Aug-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Sep-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Oct-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Nov-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Dec-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Jan-26 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Feb-25 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Mar-26 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| Apr-26 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
| May-26 | 2001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 2001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 2001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 2001AA | Coliform x 1 - Administration Area Pump House | ||
| 2001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 2001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 2001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 2001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 2001AF | Trip Fee | Not to exceed 24 in contract year |
OY3
| OY3: 01 June 2028 - 31 May 2029 | |||||||
| P/A | QT 100 | FC | |||||
| Water Testing | Amount of Contract | $ - 0 | |||||
| Month | Line Item | Description | Qty | Total Used to Date | $ - 0 |
| Jun-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | TOTAL LEFT IN CONTRACT | $ - 0 | ||||||
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Description | Line Items | Max Amt | Qty Used | Qty left | Line Item Price | Total | |||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||||||||||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||||||||||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | P/A | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | QT 100 | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | Field Chlorine | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | Coliform Retest | 3001AB | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| 3001AF | Trip Fee | Not to exceed 24 in contract year | Nitrates | 3001AC | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| Dissolved Oxygen | 3001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||||
| Jul-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | Field pH | 3001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Electrical Conductivity (EC) | 3001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | Formaldehyde, Zinc, Phenol, Nitrogen | 3001AE | 1 | 0 | 1 | $ - 0 | $ - 0 | |||
| 3001AA | Coliform x 1 - Administration Area Pump House | Trip Fee | 3001AF | 24 | 0 | 24 | $ - 0 | $ - 0 | |||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | $ - 0 | ||||||||
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |||||||||
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |||||||||
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Aug-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Sep-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Oct-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Nov-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Dec-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Jan-26 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Feb-25 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Mar-26 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| Apr-26 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
| May-26 | 3001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 3001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 3001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 3001AA | Coliform x 1 - Administration Area Pump House | ||
| 3001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 3001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 3001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 3001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 3001AF | Trip Fee | Not to exceed 24 in contract year |
OY4
| OY4: 01 June 2029 - 31 May 2030 | |||||||
| P/A | QT 100 | FC | |||||
| Water Testing | Amount of Contract | $ - 0 | |||||
| Month | Line Item | Description | Qty | Total Used to Date | $ - 0 |
| Jun-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | TOTAL LEFT IN CONTRACT | $ - 0 | ||||||
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Description | Line Items | Max Amt | Qty Used | Qty left | Line Item Price | Total | |||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||||||||||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||||||||||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | P/A | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | QT 100 | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | Field Chlorine | 48 | 0 | 48 | $ - 0 | $ - 0 | |||
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | Coliform Retest | 4001AB | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| 4001AF | Trip Fee | Not to exceed 24 in contract year | Nitrates | 4001AC | 48 | 0 | 48 | $ - 0 | $ - 0 | ||
| Dissolved Oxygen | 4001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||||
| Jul-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | Field pH | 4001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | Electrical Conductivity (EC) | 4001AD | 12 | 0 | 12 | $ - 0 | $ - 0 | |||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | Formaldehyde, Zinc, Phenol, Nitrogen | 4001AE | 1 | 0 | 1 | $ - 0 | $ - 0 | |||
| 4001AA | Coliform x 1 - Administration Area Pump House | Trip Fee | 4001AF | 24 | 0 | 24 | $ - 0 | $ - 0 | |||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | $ - 0 | ||||||||
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |||||||||
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |||||||||
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |||||||||
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Aug-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Sep-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Oct-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Nov-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Dec-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Jan-26 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Feb-25 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House | ||
| 4001AB | Coliform Re-Test | Not to exceed 60 in contract year | |
| 4001AC | Nitrates | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) | |
| 4001AD | Dissolved Oxygen | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Field pH | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AD | Electrical Conductivity (EC) | First Week Every Month - (1 Test - Tule Oxidation Pond) | |
| 4001AE | Formaldehyde, Zinc, Phenol, Nitrogen | First Week in January ONLY - (1 Test Tule Oxidation Pond) | |
| 4001AF | Trip Fee | Not to exceed 24 in contract year |
| Mar-26 | 4001AA | Coliform x 1 - Tule Day Use (3-1 Pump House) | First Week Every Month - (5 Tests: 3-1, 3-2, 4-2, RH, Admin) |
| 4001AA | Coliform x 1 - Tule Day Use (3-2 Pump House) | ||
| 4001AA | Coliform x 1 - Rocky Hill Day Use Area | ||
| 4001AA | Coliform x 1 - Administration Area Pump House |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .