This document provides information on an upcoming federal contract opportunity for construction services. The U.S. Army Corps of Engineers intends to issue a Request for Proposal to award a firm-fixed-price construction contract between $25 million and $100 million for an 852-day period of performance. The project involves building a new Consolidated Mission Control Center facility at Hill Air Force Base in Utah to replace outdated equipment and facilities currently used by the Utah Test and Training Range for air traffic control and post-mission test evaluation services. Interested vendors should monitor the beta.SAM.gov website for release of the RFP anticipated around September 10, 2020, with proposals due tentatively on October 12, 2020. Contractors are responsible for self-identifying as interested vendors on the website.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

09 September 2019

(This inspection is valid for three years from the inspection date regardless of Exp. Date of inspector cert. If past this date, a visual or additional assessment will then be required)

SIGNATURE:

PREPARED BY: Taylor Brimberry (ASB#-6727, PB#-2546)

DEMOLISH BUILDING

THIS REPORT IS NOT TO BE USED FOR BIDDING PURPOSES

ORGANIZATION:

REQUESTED:

6471326

RICHARD NEHRING

75 CEG

FACILITY CONSTRUCTION DATE:

WORK TASK#:

FACILITY:

REQUESTER:

DEPARTMENT OF THE AIR FORCE

75TH CIVIL ENGINEERING (CEOHA)

HILL AIR FORCE BASE, UTAH

LEAD BASED PAINT

ASBESTOS

LIMITED INSPECTION REPORT

Utah Certified State Inspector: Raudel Arteaga (ASB#-5863: Expires-30 November 2019, PB#-2244: Expires-11 January 2020)

INSPECTION DATE: 13 September 2019

Reference UDAQ R307-807-6

ASBESTOS

Assumed

Assumed

3% Chrysotile

6% Chrysotile

Assumed

Assumed

50 Linear Feet Attic

Roof Decking, Black Non-Friable Category I 60 Square

Feet Fire Riser Room

Roof Flashing, Black Non-Friable Category I 250 Linear

Feet Roof Flashings and Curbs

DEPARTMENT OF THE AIR FORCE

75 CIVIL ENGINEERING (CEOHA)

HILL AIR FORCE BASE, UTAH

The quantities within this report are estimates and are not to be used for bidding purposes.

SUMMARY OF ASBESTOS CONTAINING MATERIALS FOUND

MATERIAL TYPE

Attic, Pipe Chases and North Exterior Of Building

*RACM

*Category I *Category II

FRIABILITY QUANTITY

40 Linear Feet

Demolish Building.Statement of Work:

Non-Friable Category II 1,500 Square

Feet

Exterior Of The Building, Dock Edges and Exterior Walls Of The

Building

Thermal System Pipe Insulation Lagging, White/Yellow Friable RACM

Floor Tile/ Adhesive, Black

Non-Friable

LIMITED ASBESTOS INSPECTION REPORT INFORMATION

Category I 100 Square

Feet Gym Area

Block Filler Paint, Brown/Concrete

This inspection was performed in accordance with the Utah Division of Air Quality (DAQ) requirements as found in the Utah Air Quality Rule R307-801-10. This inspection report is required to be on site during all abatement, renovation, and demolition activities. Samples referenced in this report were analyzed by polarized light microscopy (PLM) utilizing method 600R-93-116 by The Science and Engineering Laboratory (AIHA Acc.#-

101572) at Hill Air Force Base, Utah (R307-801-10.8.a-b).

Thermal System Pipe Fittings, White

*LOCATIONS FOUND

RACMFriable

Civil Engineering personnel also reviewed previous asbestos inspection reports of suspect asbestos containing materials (ACM) that could potentially be encountered in the proposed area/areas. The information gathered from all current and previous inspections is shown below by homogenous area (R307-801-9-4).

A total of 81 22

Block Filler Paint, Brown/Concrete Block Filler Paint, Tan/Block Block Filler Paint, White/Block Thermal System Pipe Insulation, White/Yellow

Thermal System Pipe Insulation, Cloth/Yellow Thermal System Pipe Insulation Lagging, White/Yellow Thermal System Pipe Fitting Insulation, White/Yellow Vibration Collar, Black

Roof Sound Board, Brown Fire Caulking, Off-White/Black

2'x4' Ceiling Tile, Wormygrooves/Pinholes, White Roof Batt Insulation, Foil/Pink Wall Batt Insulation, Foil/Pink Duct Insulation, Foil/Pink

Flex Duct Insulation, Black/Pink 12" Floor Tile, Light Grey/Adhesive, Yellow 12" Floor Tile, Grey/Adhesive, Yellow Block Filler Paint, Tan/Concrete

2'x4' Ceiling Tile, Pockmarks/Pinholes, White12" Acoustical Wall Tile, Wormygrooves/Pinholes, Table 1

MATERIAL TYPE

Per Hill AFB requirements, all materials containing any detectable amount of asbestos shall be handled as Asbestos Containing Material (ACM). Table 2 shows the summary of materials containing ≤1% that were identified via "Point Counting". Per EPA/UDAQ

≤1% is not considered to be an asbestos containing material, but special handling/packaging requirements are necessary per OSHA 29CFR 1926.1101 and 29CFR

1910.1001

QUANTITY

N/A

Category I Non-Friable ACM: Asbestos-containing packings, gaskets, resilient floor coverings, or asphalt roofing products containing more than 1% asbestos as determined by using the method specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM).

The following is a list of the "Suspect Materials" that were sampled as part of this inspection:

N/A

Table 2.

ASBESTOS

suspect materials assessed as part of the inspection.samples reference the

RACM: Regulated Asbestos-Containing Material (RACM)" means friable ACM, Category I non-friable ACM that has become friable, Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading, or Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation project operations.

Locations found: Locations of building materials as described in this report indicate where they were found, but do not necessarily mean that these are the only locations where these materials may be encountered during the project.

Category II Non-Friable ACM: Any material, excluding Category I non- friable ACM, containing more than 1% asbestos as determined by using the methods specified in 40 CFR Part 763, Subpart E, Appendix E, Section 1, Polarized Light Microscopy (PLM) that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure.

*LOCATIONS FOUND

N/A N/A

Table 3.

Drywall/Joint Compound Wall System Drywall/Joint Compound Ceiling System

*Per UDAQ definition.

Per EPA requirements, all materials analyzed as containing ≤10% asbestos are point counted utilizing EPA method 600/R-93/116 this information is summarized in Table 2.

2'x4' Ceiling Tile, Wormygrooves/Pinholes Pattern, White, Multiple Locations, 7,100

Square Feet

GM192526

West Center, Hallway

Outside Room 2 None Detected

GM192527 Northeast, Room 7 None Detected

GM192528

Center, Hallway Outside

Room 7 None Detected

GM192529 South Center, Room 8 None Detected GM192530 Center, West Entry None Detected GM192531 Southwest, Room 20 None Detected

Center, Room 8A None Detected GM192523 North Center, Room 17 None Detected GM192524 Northeast, Room 20 None Detected GM192525 East Center, Room 2 None Detected

The following table summarizes the sampling data.

Homogenous Building Material, Description, Location, Quantity.

GM192506 Northeast, Break Room

GM192517 Northwest, Room 4 None Detected

GM192518 Center, Room 2 None Detected

None Detected

GM192503 Southwest, Room 19 None Detected Northeast, Room 20 None Detected

GM192505 Southeast, Electrical Room None Detected

GM192500 Northeast, Room 7 None Detected GM192501 Southwest, Room 8

12" Acoustical Wall Tile, Wormygrooves/Pinholes Pattern, White Over Puck, Brown, Multiple Locations, 3,200 Square

Feet

GM192516 East Center, Room 6 None Detected

Drywall/Joint Wall System, Multiple Locations, 45,000 Square Feet

Drywall/Joint Compound Ceiling System, Multiple Locations, 2,000 Square Feet

None Detected

GM192508 Northwest, Main Entry None Detected GM192509 Southwest, Room 1 None Detected

GM192511

GM192513 Northwest, North Entry None Detected

GM192514

North, Garage Server

Room None Detected

GM192504

GM192507 Southwest, Main Hallway

GM192515

ResultsSample Location

South Center, Janitor's Closet

None Detected

GM192510

Northeast, Hallway Outside Restroom

None Detected

None Detected Southeast, Hallway

Outside Room 8

GM192512

GM192519

East, Hallway Outside

Room 6 None Detected

2'x4' Ceiling Tile, Pockmarks/Pinholes Pattern, White, Multiple Locations, 7,100 Square Feet

GM192520 East Center, Room 7 None Detected GM192521 Southeast, Room 8 None Detected

GM192522

None Detected

Sample #

Southeast, Room 6

None Detected GM192502 Northeast, Room 17 None Detected

GM192574 East Center None Detected

GM192567 Center 6% Chrysotile

Vibration Collar, Black, Attic Mezzanine, 75 Linear Feet

GM192571 East None Detected

GM192572 Center None Detected

Thermal System Pipe Fitting Insulation, White Over Yellow, Attic Mezzanine, 50 Linear Feet

GM192568 Center 6% Chrysotile GM192569 Center 5% Chrysotile

GM192570 Center None Detected

Thermal System Pipe Insulation Lagging, White Over Yellow, Attic, 100 Linear Feet

GM192573 Center None Detected

GM192561 South Center None Detected Block Filler Paint, White Over Block, Janitor's

Closet, 5,000 Square Feet

Thermal System Pipe Insulation, Cloth Over Yellow, Attic, 800 Linear Feet

GM192562 Center None Detected GM192563 North Center None Detected GM192564 Center None Detected

Thermal System Pipe Insulation, White Over Yellow, Attic, 1,500 Linear Feet

GM192565 North Center None Detected GM192566 South Center None Detected

GM192558 Southwest 2% Chrysotile Block Filler Paint, Tan Over Block, Exterior Of

Building, 1,000 Square Feet GM192559 East Center None Detected

GM192560 East Center None Detected

GM192551 South Center None Detected GM192552 Northeast None Detected

Block Filler Paint, Tan Over Concrete, Exterior Of Building, 65,000 Square Feet

Block Filler Paint, Brown Over Concrete, Exterior Of Building, 1,500 Square Feet

GM192553 Southeast None Detected GM192554 West Center None Detected GM192555 Southwest None Detected

12" Floor Tile, Grey Over Adhesive, Yellow, Break Room, 80 Square Feet

GM192556 East Center None Detected GM192557 West Center 3% Chrysotile

South Center None Detected GM192545 Southeast None Detected GM192546 Center None Detected

12" Floor Tile, Light Grey Over Adhesive, Yellow, Break Room, 80 Square Feet

GM192547 Northeast None Detected GM192548 Northwest None Detected GM192549 South Center None Detected

Flex Duct Insulation, Black Over Pink, Attic, 800 Linear Feet

GM192550 West Center None Detected

GM192537 Center None Detected

Duct Insulation, Foil Over Pink, Attic, 1,500 Linear Feet

GM192541 East Center None Detected GM192542 East Center None Detected GM192543 North Center None Detected

Wall Batt Insulation, Foil Over Pink, Attic, 10,000 Square Feet

GM192538 South Center None Detected GM192539 Southeast None Detected GM192540 West Center None Detected

GM192544

Roof Batt Insulation, Foil Over Pink, Attic, 14,200 Square Feet

GM192532 Center None Detected GM192533 East Center None Detected GM192534 South Center None Detected GM192535 South Center None Detected GM192536 North Center None Detected

GM192580 West Center None Detected

Fire Caulking, Off-White Over Black, Attic Mezzanine, 10 Square Feet

GM192576 Center None Detected GM192577 South Center None Detected GM192578 West Center None Detected

Roof Sound Board Insulation, Brown, Attic, 1,000 Square Feet

GM192575 Center None Detected

GM192579 West Center None Detected

Cell: (801)430-3976 Supervisor: Traver Andreasen: DSN: (801)586-7094

Asbestos/LBP Shop 75 CES(CEOHA)

Asbestos/LBP Shop Personnel

DSN:(801)777-8006

CONTACT INFORMATION

Table 4.

POTENTIAL FOR ADDITIONAL MATERIALS:

This inspection report only encompasses the areas/materials designated within the scope of work that was provided at the date of inspection (see title page for inspection date). Should the scope of the project be altered in any way or any materials found that are not identified in this report shall require additional assessment. This report cannot be used for any other projects within the building.

Any questions or concerns regarding this inspection report or if any new suspect asbestos containing material (ACM) is encountered, stop work and contact the personnel listed below for further assistance/assessment.

SCOPE OF WORK:

XL Number Substrate Component Color Lead Reading Paint

Condition 1520 Metal Handrail Brown 5.19 Fair 1566 Ceramic 4" Wall Tile Yellow 6.66 Good 1572 Ceramic 4" Wall Tile Yellow 5.46 Good 1580 Ceramic 4" Floor Tile Yellow 4.89 Poor 1582 Metal Handrail Brown 2.70 Fair 1593 Metal Handrail Brown 2.07 Poor 1594 Metal Dock Post Brown 3.08 Poor

5-This inspection report only encompasses the areas/materials designated within the scope of work that was provided at the date of the inspection (see title page for date). This report must be modified should the scope of the project be altered in any way or additional materials not previously identified within this report are encountered. This report may not be used for any other projects within the building.

LIMITED LEAD-BASED PAINT IDENTIFICATION REPORT INFORMATION

Table 1.

DEPARTMENT OF THE AIR FORCE

75TH CIVIL ENGINEERING (CEOHA)

HILL AIR FORCE BASE, UTAH

1-Table 1 below, summarizes the painted/coated building components that tested positive for Lead Based Paint/Coating. These components should be segregated or abated prior to renovation or demolition, and a composite TCLP taken of the waste before disposal.

2-The condition column is the condition only of the painted/coated component (See final page for all readings/samples).

Demolish Building.

3-The U.S. Department of Housing and Urban Development defines Lead-based paint as any paint, varnish, stain, or other applied coating that has 1 mg/cm² as measured by an X-ray Fluorescence (XRF) Analyzer or laboratory analysis or 0.5 percent by weight (5,000 µg/g by dry weight) by laboratory analysis, or more of lead.

All other components tested were less than 0.80 mg/cm².

4-Any effort to disturb lead paint can create lead dust. Ensure that appropriate abatement, cleanup, and disposal will be accomplished and that appropriate safety measures are taken IAW 29 CFR 1926.62. If you have any questions concerning this report, contact the Asbestos/LBP Shop: Traver Andreasen at 586-7094.

Building: 1276 WT/CP# 6471326 Date: 13 September 2019

1481 1.02 1607 0.89 1482 1.16 1608 0.87

1483 0.95 POS 1609 0.94

Range: .8 to 1.2 Paint Range: .8 to 1.2 Side Condition Color PbL(mg/cm2) NEG/POS

Center Fair Silver 0.01 NEG Center Poor Brown 0.03 NEG Center Poor Silver 0.01 NEG Center Fair Silver 0.02 NEG Center Fair Red 0.71 NEG Center Fair Green 0.02 NEG Center Good Blue 0.04 NEG South Good Brown 0.01 NEG South Good Tan 0.07 NEG South Good Green 0.03 NEG South Good Green 0.02 NEG West Good Brown 0.01 NEG West Good Brown 0.01 NEG East Good Tan 0.01 NEG West Good Brown 0.01 NEG West Good Green 0.01 NEG East Good White 0.10 NEG East Good Grey 0.01 NEG East Good Brown 0.01 NEG

Center Fair Grey 0.12 NEG West Good Off-White 0.01 NEG South Good Off-White 0.01 NEG North Good Off-White 0.01 NEG North Good Off-White 0.01 NEG North Good Brown 0.01 NEG North Good Brown 0.01 NEG South Good Grey 0.01 NEG South Good White 0.01 NEG East Good Brown 0.01 NEG East Good Brown 0.01 NEG

Per 20 Second Reading

Calibration Range

Substrate

North Garage Restroom Wood Wood

Door CasingNorth Garage Restroom

Attic Pipe Support Bracket Metal

1513 Door Jamb

Post Calibration

PbL (mg/cm²)XRF Analyzer XL3t 300 (Serial #96588)

Per 20 Second Reading

1485 Attic Handrail Metal 1484 Attic Expansion Tank Metal

Pre Calibration PbL (mg/cm²) Calibration

Range Model# Serial #

XL Number Room/Area Structure

1486 Attic Landing Structural Steel Angle Metal

1489 Attic Pump Motor Metal 1488 Attic Pump Metal

1491 Room 4 Door Frame Metal 1490 Attic Pump Motor Metal

1493 Room 4 Suspended Floor Stand Metal 1492 Room 4 Door Metal

1495 Room 4 Door Jamb Metal 1494 Room 4 Suspended Floor Plate Metal

1497 Room 4 Wall Drywall 1496 Room 4 Door Metal

1499 Room 4 Equipment Metal 1498 Room 4 Equipment Metal

1501 Room 4 East Room Door Jamb Metal 1500 Room 4 East Room Wall Concrete

1503 North Garage Floor Concrete 1502 Room 4 East Room Door Jamb Metal

1505 North Garage Server Room Wall Concrete 1504 North Garage Server Room Wall Block

1506 North Garage Server Room Ceiling Drywall

1509 North Garage Server Room Door Metal 1508 North Garage Server Room Door Jamb Metal

1511 North Garage Restroom Wall Drywall 1510 North Garage Restroom Wall Drywall

1507 North Garage Server Room Trim Wood

1481 1.02 1607 0.89 1482 1.16 1608 0.87

1483 0.95 POS 1609 0.94

Range: .8 to 1.2 Paint Range: .8 to 1.2 Side Condition Color PbL(mg/cm2) NEG/POS East Good Brown 0.01 NEG

South Good Brown 0.01 NEG North Good Grey 0.02 NEG North Good Grey 0.34 NEG North Good White 0.13 NEG North Good Brown 0.01 NEG East Fair Brown 5.19 POS East Fair Grey 0.02 NEG East Fair Grey 0.49 NEG East Good Grey 0.01 NEG

South Poor Red 0.01 NEG South Poor Black 0.01 NEG West Good Grey 0.01 NEG West Good Grey 0.01 NEG South Good White 0.01 NEG West Good Off-White 0.01 NEG West Good Grey 0.01 NEG West Good Varnish 0.01 NEG West Good Tan 0.01 NEG East Good Tan 0.01 NEG East Good Varnish 0.01 NEG East Good Brown 0.01 NEG East Good Brown 0.02 NEG East Good Grey 0.01 NEG East Good White 0.01 NEG East Good Green 0.01 NEG East Good Grey 0.01 NEG East Good Tan 0.01 NEG West Good Blue 0.02 NEG South Good Green 0.01 NEG

1542 Room 16 Chair Rail Wood 1543 Room 16 Wall Wall Paper

1539 Room 19 Wall Drywall 1540 Room 19 Door Jamb Metal 1541 Room 19 Door Jamb Metal

1536 Room 21 Door Jamb Metal 1537 Room 19 Wall Drywall 1538 Room 19 Chair Rail Wood

1533 Room 21 Drywall Drywall 1534 Room 21 Chair Rail Wood 1535 Room 21 Wall Drywall

1530 Room 20A Door Jamb Metal 1531 Room 20A Door Wood 1532 Room 20A Door Jamb Metal

1527 West Entry Door Metal 1528 West Entry Wall Drywall 1529 Room 20A Wall Drywall

1524 Southeast Storage Room Floor Line Concrete 1525 Southeast Storage Room Floor Line Concrete 1526 West Entry Door Jamb Metal

1521 Southeast Storage Room Rollup Door Channel Metal 1522 Southeast Storage Room Rollup Door Metal 1523 Southeast Storage Room Wall Casing Metal

1518 Northeast Gym Wall Drywall 1519 Northeast Gym Chair Rail Wood 1520 Exterior Handrail Metal

1515 North Garage Wall Concrete 1516 North Garage Rollup Door Frame Metal 1517 North Garage Rollup Door Metal

Per 20 Second Reading

Per 20 Second Reading

XL Number Room/Area Structure Substrate 1514 North Garage Restroom Door Wood

Pre Calibration PbL (mg/cm²) Calibration

Range Model# Serial # Post

Calibration PbL

(mg/cm²) Calibration

RangeXRF Analyzer XL3t 300 (Serial #96588)

1481 1.02 1607 0.89 1482 1.16 1608 0.87

1483 0.95 POS 1609 0.94

Range: .8 to 1.2 Paint Range: .8 to 1.2 Side Condition Color PbL(mg/cm2) NEG/POS East Good Lacquer 0.06 NEG West Good Blue 0.08 NEG West Good Lacquer 0.01 NEG West Good White 0.03 NEG

Center Good White 0.08 NEG West Good Grey 0.01 NEG North Good White 0.06 NEG North Good White 0.12 NEG West Good White 0.20 NEG West Good White 0.27 NEG West Good White 0.29 NEG West Good White 0.01 NEG West Good White 0.01 NEG South Good Grey 0.01 NEG West Good Red 0.34 NEG West Good White 0.60 NEG South Good White 0.01 NEG West Good Tan 0.01 NEG

Center Good Tan 0.01 NEG North Good Tan 0.01 NEG East Good White 0.01 NEG East Good White 0.01 NEG

South Good Yellow 6.66 POS Center Good Yellow 0.01 NEG Center Good Yellow 0.01 NEG South Good Tan 0.01 NEG South Good White 0.01 NEG Center Good Light Yellow 0.01 NEG South Good Yellow 5.46 POS Center Good Yellow 0.01 NEG

1571 Men's Restroom Ceiling Drywall 1572 Men's Restroom 4" Wall Tile Ceramic 1573 Men's Restroom 2" Floor Tile Ceramic

1568 Janitor's Closet 2" Floor Tile Ceramic 1569 Janitor's Closet 4" Wall Tile Ceramic 1570 Janitor's Closet Wall Ceramic

1565 Women's Restroom Ceiling Drywall 1566 Janitor's Closet 4" Wall Tile Ceramic 1567 Janitor's Closet 1" Floor Tile Ceramic

1562 Women's Restroom 12" Floor Tile Ceramic 1563 Women's Restroom Partition Metal 1564 Women's Restroom Wall Drywall

1559 Electrical Room Wall Board Wood 1560 Electrical Room Wall Board Wood 1561 Women's Restroom 4" Wall Tile Ceramic

1556 Storage Closet Header Wood 1557 Room 2 Wall Drywall 1558 Electrical Room Wall Board Wood

1553 Storage Closet Door Wood 1554 Storage Closet Door Jamb Wood 1555 Storage Closet Header Wood

1550 Break Room Wall Drywall 1551 Break Room Chair Rail Wood 1552 Storage Closet Casing Wood

1547 Hall Wall Block 1548 Hall Ceiling Drywall 1549 Room 8A Wall Drywall

1544 Room 12 Hall Chair Rail Wood 1545 Room 14 Wall Drywall 1546 Room 14 Chair Rail Wood

PbL (mg/cm²)

Calibration RangeXRF Analyzer XL3t 300 (Serial #96588)

Per 20 Second Reading

Per 20 Second Reading

XL Number Room/Area Structure Substrate

Pre Calibration PbL (mg/cm²) Calibration

Range Model# Serial # Post

1481 1.02 1607 0.89 1482 1.16 1608 0.87

1483 0.95 POS 1609 0.94

Range: .8 to 1.2 Paint Range: .8 to 1.2 Side Condition Color PbL(mg/cm2) NEG/POS

Center Good Yellow 0.01 NEG North Good Yellow 0.01 NEG North Good Brown 0.01 NEG South Good White 0.01 NEG South Good White 0.05 NEG East Good Grey 0.03 NEG

North Poor Yellow 4.89 POS North Poor White 0.40 NEG West Fair Brown 2.70 POS West Fair Tan 0.01 NEG West Fair Tan 0.07 NEG West Poor Brown 0.01 NEG West Poor Brown 0.01 NEG West Good Brown 0.01 NEG West Good Brown 0.01 NEG West Fair Tan 0.61 NEG West Poor Brown 0.01 NEG West Poor Yellow 0.01 NEG South Poor Brown 0.17 NEG South Poor Brown 2.07 POS South Poor Brown 3.08 POS East Poor Brown 0.02 NEG East Poor Brown 0.02 NEG North Fair Black 0.09 NEG North Poor Brown 0.01 NEG North Brown 0.01 NEG1599 Fire Riser Room FDC Connection Metal

1596 Exterior Stair Handrail Metal 1597 Exterior Gate Metal 1598 Exterior Tank Bollard Metal

1593 Exterior Handrail Metal 1594 Exterior Dock Post Metal 1595 Exterior Stair Stringer Metal

1590 Exterior Dock Edge Concrete 1591 Exterior Dock Edge Concrete 1592 Exterior Handrail Metal

1587 Exterior Door Jamb Metal 1588 Exterior Door Metal 1589 Exterior Down Spout Metal

1584 Exterior Wall Concrete 1585 Exterior Wall Concrete 1586 Exterior Wall Block

1581 Room 23 4" Floor Tile Concrete 1582 Exterior Handrail Metal 1583 Exterior Wall Stucco

1578 Men's Restroom Sink Ceramic 1579 Men's Restroom Dispenser Metal 1580 Room 23 4" Floor Tile Concrete

1575 Men's Restroom Partition Metal 1576 Men's Restroom Partition Metal 1577 Men's Restroom Urinal Ceramic

Per 20 Second Reading

Per 20 Second Reading

XL Number Room/Area Structure Substrate 1574 Men's Restroom 1" Floor Tile Ceramic

Pre Calibration PbL (mg/cm²) Calibration

Range Model# Serial # Post

Calibration PbL

(mg/cm²)

RangeXRF Analyzer XL3t 300 (Serial #96588)

Title Page
Asbestos
LBP
Readings
2019-10-16T12:19:23-0600
BRIMBERRY.TAYLOR.MIKE.1543589558
GM192505:
Southeast Electrical Room:
None Detected:
GM192507:
Southwest Main Hallway:
None Detected_2:
GM192510:
None Detected_3:
GM192512:
None Detected_4:
GM192514:
None Detected_5:
GM192519:
None Detected_6:
GM192526:
None Detected_7:
GM192528:
None Detected_8:
GM192559:
East Center:
None Detected_9:
Range 8 to 12:
Range 8 to 12_2:
Range 8 to 12_3:
Range 8 to 12_4:
PoorFDC Connection: