About this file

Quantico-Dahlgren Facilities List REV1

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SECTION J-1 FACILITIES 1 2 3 4

FACILITY NAME: Crossroads ES Community Superintendent's

Office (formerly Burrows ES) Quantico MHS Dahlgren EMS

INSTALLATION: Quantico, VA Quantico, VA Quantico, VA Dahlgren VA

LOCATION: BLDG 3315 BLDG 3308 BLDG 3307 BLDG 0193

ADDRESS:

3315 Purvis Road

Quantico, VA 22134-1702

3308 John Quick Rd, Quantico, VA 22134

3307 Purvis Rd, Quantico, VA

22134

6117 Sampson Rd, Suite 206

BLDG 193, Dahlgren VA 22448

COUNTY: Prince William Prince William Prince William King George FACILITY USE (Grades): Grades PreK - 5 Grade 4-5 Grades 6-12 Grades PreK - 8

GROSS SQUARE FOOTAGE: 129,570 42,495 81,407 43,369

KITCHEN/CAFETERIA? Yes No Yes No

MULTIPURPOSE ROOM/AUDITORIUM? Commons/Multipurpose No No Auditorium

GYMNASIUM? Yes Yes yes yes

MAJOR MECHANICAL SYSTEMS:

geothermal heat pump system with cooling tower, reversed chiller hot water re-heat system

4 pipe single duct vav system.

Air cooled chillers and gas fired boilers provide water to air handling units located on roof.

VAV bozes do not contain reheat coils.

geothermal heat pump system hydronic radiant heater units.

Water heaters (electric/oil).

Unit heaters. Air

Compressors/condensors.

Water cooled chillers

PRIMARY TYPE OF CONSTRUCTION:

CMU exterior and interior walls with partial standing seam metal roof and partial low-slope roof.

CMU exterior and interior walls with pitched shingle roof

CMU interior and exterior walls with membrance roofing system

CMU interior and brick veneer over concreate masonry exterior walls with a modified bitumen roofing system.

YEAR OF CONSTRUCTION: 2014 1987 1960 1942-1966

MAINTENANCE SECTIONS

Section C-3 (Mech) Yes Yes Yes Yes

Section C-4 (DDC) Yes Yes Yes Yes

Section C-5 (Plumbing) Yes Yes Yes Yes

Section C-6 (Electrical) Yes Yes Yes Yes

Section C-7 (Kitchen Equipment) Yes No Yes No

Section C-8 (Roof Systems & Site) Yes Yes Yes Yes

Section C-9 (Building Systems) Yes * Yes * Yes * Yes

Section C-10 (Fire Alarm & Suppression) No No No Yes

Section C-11 (Playgrounds) Yes No No Yes

* Elevators only