A-11_MATOC_Exhibits_A_-C_-_1_May.docx

DOCX document 43 KB Posted

Attached to
Multiple Award Task Order Contract (MATOC), Utah National Guard Federal contract opportunity
Solicitation number
W911YP-13-R-2202
Issued by
Department of the Army National Guard

About this file

Utah National Guard MATOC Exhibits A-C

View the file

Other files for this federal contract opportunity

Other files attached to Multiple Award Task Order Contract (MATOC), Utah National Guard, newest first.
File Type Posted
RFI_5-05June2013.pdf PDF
RFI_4-22May2013.pdf PDF
Sign_In_Sheet.pdf PDF
Pre-Proposal_Meeting_Minutes_-_13-R-2202_-_Signed.pdf PDF
Utah_NG_MATOC_Preproposal_Conference_21_May_2013.pdf PDF
RFI__3_-_16_May_2013.pdf PDF
Prototypical_Proj_B55_100percent_Half_Size_Dwgs.pdf PDF
Utah_Prototypical_Proj-B55_100_percent_Specs.pdf PDF
A-11_MATOC_Exhibit_D_-_1_May.docx DOCX document
RFI__1_-_08_May_2013.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IDIQ MATOC RFP W911YP-13-R-2202

EXHIBIT A PERFORMANCE RELEVANCY QUESTIONNAIRE

PART 1: Prepare not more than six (6) Part 1 forms for general construction.

Provide the following information requested in this format for each of the projects/contracts being described. Contractors should select their projects carefully because the quality of the contractor’s relevant performance is more important than the quantity of projects submitted. Projects may be on going, if complete to 70 % and cannot have been completed any earlier than 5 years prior to the solicitation issue date. . Provide frank, concise comments regarding YOUR PERFORMANCE on the contracts you identify. Use as much space as required.

A. Offeror (Your) Name (Company/Division):_______________________________________

B. Project/Contract Title:________________________________________________________

C. Contract Specifics:

1. Description of Effort as ___________Prime Contractor or _________Subcontractor

2. Contract Number__________________________________________________________

3. Original Contract $ Value _____________ Current/Final Contract $ Value ____________

4. If amounts in 3 above are different, provide a brief description of the reason:

5. Award and Completion

i. Award date: __________________Original Completion Date:_____________________

ii. Current Scheduled Completion Date( if ongoing): _____________ % complete: _____
iii. Estimate/Final Completion Date:_________________________________________
iv. If IDIQ Number of Task Orders issued:____________________________________

**If reference is for an IDIQ Contract provide items 1-3 above, contract completion date and number of task/delivery orders issued. The Basic Contract will not count as one of 6 contracts/projects. The basic contract alone will not be considered for relevancy. The proposal must discuss relevant task order(s) complete to 90%. Count each TO that is discussed as a single project/contract**

Task Order Number _____________________________________________________ Title__________________________________________________________________ Original TO $ Value _____________ Current/Final $ Value _____________________ If amounts above are different, provide a brief description of the reason:

Task Order Completion Date:

1. Original Date: _____________________________________________

2. Current Schedule if ongoing _________________________________% complete: _____

3. Estimate/Final Completion Date: _______________________________

4. Primary cause for Contract Modifications________________________

D. Provide detailed description of the work performed under the contract and describe why you believe the work is very relevant, relevant or somewhat-relevant to this solicited contract. Also discuss similarity of the client type, United States Green Building Council (USGBC) (LEED®) or similar sustainability requirements. Use as much space below as necessary to provide this description.

Exhibit A Part I continues on Next Page… Additionally, please address the following items:

1. Describe the specific elements of the work performed by your firm.

2. Indicate what elements of work were performed by your major subcontractors and indicate if those same subcontractors will be used on MATOC projects.

3. Address any technical areas about this project you consider uniquely relevant to this solicitation.

4. Point of Contact for Owner/Government agency Contracting Officer and or inspector; include a current phone number and facsimile number. Email address is also desired.

End of Part 1- Questionnaire Requirements – Prepare and send Exhibit C Package to the reference(s) for each of the six (6) General Construction projects. A “Final” Performance Evaluation (Construction) (also referred to as CCASS Evaluation) issued for a project may be included in lieu of sending out reference package for the project. If providing a Performance Evaluation (Construction) place the document directly behind the project it applies to.

EXHIBIT A PERFORMANCE RELEVANCY QUESTIONNAIRE

PART 2: Provide the following information one time.

Additional offeror information required, but not project specific. This information need only be provided once in your submission package.

2A: Applicable to all offerors - Describe your Compliance with the requirements of FAR clause 52.219-8, Utilization of Small Business Concerns (May 2004). Describe below the methods you have used to comply with this policy on prior federal contracts. Include any evidence, or a point of contact to verify this information, if available.

Even if you are a Small or Small Disadvantaged Business, this clause in Federal Contracts applies. It is the policy of the United States that small business concerns, veteran-owned small business concerns, service-disabled veteran-owned small business concerns, HUBZone small business concerns, small disadvantaged business concerns, and women-owned small business concerns shall have the maximum practicable opportunity to participate in performing contracts let by any Federal agency, including contracts and subcontracts for subsystems, assemblies, components, and related services for major systems.) It is also policy to establish procedures to ensure the timely payment of amounts due pursuant to the terms of their subcontracts.

2B: Name subcontractors and/or Teaming Partners to be utilized on this contract. Multiple subcontractors may be named for the same discipline, but are limited to a maximum of three (3) subcontractors per discipline. As a minimum, provide the name(s) of subcontractors to be utilized in the following areas:

Electrical:

Mechanical:

Roofing:

Horizontal disciplines: (include paving and civil site work)

Each major subcontractor and/or Teaming Partner must also complete an Exhibit B, “Subcontractor Information and Consent Form” to be considered. Offerors shall have major subcontractors identify on the Exhibit B three references, owners (if they were the Prime) or other Prime contractors they have worked for. References for subcontractors from the proposing offeror are not acceptable. See Exhibit “B” format for information to be provided. Written references for subcontractors may be included and are encouraged. However, subcontractors do not need to send out Exhibit C questionnaires.

2C: Discuss assessment of liquidated damages on any contracts within the last five years. (frequency, circumstances, severity of problem, etc.)

2D: Offerors are strongly encouraged to include with their proposals information on problems encountered on relevant projects and the specific corrective actions taken to remedy the problems.

2E: (OPTIONAL) Other Past Performance Considerations. Information, if provided, shall be limited to the period starting 5 years prior to the solicitation release date. Page limit on this question is 8 pages.

Effectiveness of value engineering (VEC) proposals you submitted on prior contracts. (Provide a brief description; impact on cost, schedule, efficiency or quality; contract number; name and phone number of customer benefiting from the VEC).

Limit of five (5) of the following: Professional/Industry awards (Identify award type, date of award and copy of certificate if applicable), Letters of appreciation, recognition or commendations.

Discuss unique skills and accomplishments (Explain unique skills and/or accomplishments and provide supporting information for verification).

IDIQ MATOC RFP W91YP-13-R-2202

EXHIBIT B – SUBCONTRACTOR INFORMATION AND CONSENT FORM

Subcontractor and/or Teaming Partner Consent for the Release of Past Performance Information to the Prime Contractor and Reference Information

Past performance information concerning subcontractors and teaming partners cannot be disclosed to a private party without the subcontractor’s or teaming partner’s consent. Because a prime contractor is a private party, the Government will need that consent before disclosing subcontractor/teaming partner past and present performance information to the prime during exchanges. In an effort to assist the Government in assessing your past performance we request that the following consent form be completed by the major subcontractors/teaming partners identified in your proposal. The completed consent forms should be submitted to the offering contractor for submission with past performance volume.

___________________(Name of Firm) is currently planning on participating as a (subcontractor and or a teaming partner) with ___________________(prime contractor or name of entity providing proposal) in responding to the Request for Proposal No. W911YP-13-R-2202 for IDIQ Multiple Award Task Order Contract (MATOC) for construction projects issued by the Utah Air National Guard for multiple Air and Army National Guard locations in the State of Utah.

We understand that the Government is placing increased emphasis on past performance in order to obtain best value in source selections. In order to facilitate the performance confidence assessment process we are signing this consent form to allow you to discuss our past and present performance information with the prime contractor during the source selection process.

(Signature)(Title of Individual with authority to sign for and
Legally bind the company)

Company Name: ________________________ Telephone #____________________

Address: ______________________________

City/State/Zip Code:______________________ Date:_____________________

Reference List (required):

1. Contract No. And Title___________________________________________________________ Describe your role (Prime/Sub) and work Performed ___________________________________ Reference POC Name____________________________ Phone___________ Fax____________ Email address: _________________________________________________________________

2. Contract No. And Title___________________________________________________________ Describe your role (Prime/Sub) and work Performed ___________________________________ Reference POC Name____________________________ Phone___________ Fax____________ Email address: _________________________________________________________________

3. Contract No. And Title___________________________________________________________ Describe your role (Prime/Sub) and work Performed ___________________________________ Reference POC Name____________________________ Phone___________ Fax____________ Email address: _________________________________________________________________

EXHIBIT C PACKAGE INFORMATION AND FORMS - A “Final” Performance Evaluation (Construction) ( also referred to as CCASS Evaluation ) issued for a project may be included in your proposal in lieu of sending out reference package for the project. Place the Evaluation directly behind the Exhibit A it is for.

Instructions to Offeror for sending Reference Questionnaire Forms: Prepare and send a reference questionnaire package for each project listed on your Exhibit A, Performance Relevancy Questionnaires. For Government contracts, send to Contracting Officer or Technical Representative. For commercial references send to personnel with duties similar to those for Government contracts. It is your responsibility to follow-up and to encourage your references to send in their questionnaire. If you have multiple references at one location (Base etc.), Send one cover letter and questionnaire for each contract you want a reference for. Your questionnaire package should contain the following.

Cover Letter (See SAMPLE) (Exhibit C1) Respondent Info Rating Sheets (Exhibit C2) (the next 4 pages) Offeror should put name in spaces indicated and ensure it is on every page for identification purposes Suggested - Pre Addressed stamped envelope to return to Contracting Officer.

OFFEROR SHOULD PLACE THEIR NAME ON TOP OF EACH QUESTIONNAIRE PAGE!!!

OFFEROR SHOULD DELETE THESE INSTRUCTIONS BEFORE SENDING OUT QUESTIONNAIRES

EXHIBIT C1

SAMPLE TRANSMITTAL LETTER

AND

PAST PERFORMANCE EVALUATION QUESTIONNAIRE

Your Company Letterhead

Date: _________________ To: ______________________________________

We have listed your firm/agency as a reference for the work we have performed for you as listed below. Our firm is submitting a proposal for a Multiple Award Construction Task Order Contract advertised by the 151st ARW, Utah Air National Guard, Salt Lake City, Utah. In accordance with Federal Acquisition Regulations (FAR), they will evaluate our firm's past performance. Your candid response to the attached questionnaire will assist the evaluation team in this process. We understand that you have a busy schedule and your participation in this evaluation is greatly appreciated. Please complete the enclosed questionnaire as thoroughly as possible. A “Final” Performance Evaluation (Construction) (also referred to as CCASS Evaluation) issued for a project may be included in lieu of completing the reference package for the project. Space is provided for comments. Understand that while the responses to this questionnaire may be released to the offeror, FAR 15.306 (e) (4) prohibits the release of the names of the persons providing the responses. Complete confidentiality will be maintained. Only one response from each office is required.

Please send your completed questionnaire to the following address to arrive NOT LATER THAN 11 June 2013. Do not return them to our company.

151st ARW, Utah ANG Base Contracting Office 765 North 2200 West Salt Lake City, Utah 84116-2926

Or shelley.schrader@ang.af.mil and chad.heard@ang.af.mil or Fax (801) 245-2339

If you have questions regarding the attached questionnaire, or require assistance, please contact Ms. Shelley Schrader, (801) 245-2105, shelley.schrader@ang.af.mil or MSgt Chad Heard, (801) 245-2338, chad.heard@ang.af.mil. Thank you for your assistance. E-Mail is preferred.

Signature and Title

EXHIBIT C2

SOURCE SELECTION SENSITIVE WHEN COMPLETED*****NOT TO BE RELEASED OUTSIDE GOVERNMENT CHANNELS***** RETURN THIS PAGE WITH QUESTIONNAIRE

RATING DESCRIPTIONS: Use the following descriptions as guidance in providing ratings.

RATING
DEFINITION
Outstanding (O)
Indicates the contractor’s performance record within the area of evaluation Exceeded that required by the contract.
Above Average (A)
Indicates the contractor’s performance record within the area of evaluation Met All contractual requirements.
Satisfactory (S)
Indicates the contractor’s performance record within the area of evaluation Met Essentially All contractual requirements.
Marginal (M)
Indicates the contractor’s performance record within the area of evaluation Met Some of the contractual requirements. However, changes to the contractor’s existing processes may be necessary in order to achieve contract requirements.
Unsatisfactory (U)
Indicates the contractor’s performance record within the area of evaluation Failed to Meet the minimum Government requirements.
Unknown or Not Applicable (N/A)
The question does not apply. No performance record identifiable within the area of evaluation.

RESPONDENT IDENTIFICATION AND RATINGS

(Part 1 Contractor submitting Proposal fill-in) Reference is provided for:

Contract Number:

Project Title:

Date of Award:

Project Completion Date:

Project Location:

Dollar Value:
$

Brief Description of Proj:

Your role in referenced contract:

(Part 2 Person providing Reference) Reference is provided by:

Company/Agency:

Business Address:

Telephone Number:

Email Address:

Project Completion Date:

Relationship to Contract:

If information in Part I is not accurate please indicate.

To obtain an electronic version of the form please contact: Ms. Shelley Schrader, (801) 245-2105, shelley.schrader@ang.af.mil or MSgt Chad Heard, (801) 245-2338, chad.heard@ang.af.mil.

THE QUESTIONNAIRE SHOULD BE SUBMITTED BY THE FOLLOWING MEANS: Return via FAX Commercial (801) 245-2339 or DSN 245-2339 or via email to the email address shown above. Forms may be mailed to 151st ARW, Base Contracting Office, 765 North 2200 West, Salt Lake City, Utah 84116-2926.

Mark cover sheet: (Attention: RFP W911YP-13-R-2202 “Source Selection Sensitive Information”)

IDIQ MATOC, RFP W911YP-13-R-2202

Please provide evaluation of the following Performance Elements by placing an X in the appropriate column that corresponds to the rating definitions on the previous page.

QUALITY CONTROL

Outstanding
Above Average
Satisfactory
Marginal
Unsatisfactory
Not Applicable
(O)
(A)
(S)
(M)
(U)
(N/A)

Quality of Workmanship

Adequacy of the quality control plan

Implementation of the Quality Control Plan

Quality of the Quality Control Documentation

Storage of Materials

Adequacy of Materials

Adequacy of Submittals

Adequacy of Quality Control Testing

Adequacy of As-Builts

Use of Specified Materials

Identification/Correction of Deficient work in a timely manner

Comments on Quality Control:

TIMELY PERFORMANCE

(O)
(A)
(S)
(M)
(U)
(N/A)

Adequacy of Initial Progress Schedule

Adherence to Approved Schedule

Resolution of Delays

Submission of Required Documentation

Completion of Punchlist Items

Submission of Updated and Revised Progress Schedules

Warranty Response

Comments on Timely Performance:

EFFECTIVENESS OF MANAGEMENT

(O)
(A)
(S)
(M)
(U)
(N/A)

Cooperation and Responsiveness

Management of Resources/Personnel

Coordination and Control of Subcontractors

Adequacy of Site Clean Up

Effectiveness of Job-Site Supervision

Compliance with Laws and Regulations

Professional Conduct

Review/Resolution of Subcontractor Issues

Implementation of Subcontracting Plan

Comments on Effectiveness of Management:

COMPLIANCE WITH LABOR STANDARDS

(O)
(A)
(S)
(M)
(U)
(N/A)

Correction of Noted Deficiencies

Payrolls Properly Completed and Submitted

Compliance with Labor Laws and Regulations with Specific Attention to the Davis-Bacon Act and EEO Requirements

Comments on Compliance With Labor Standards:

COMPLIANCE WITH SAFETY STANDARDS

(O)
(A)
(S)
(M)
(U)
(N/A)

Adequacy of Safety Plan

Implementation of Safety Plan

Correction of Noted Deficiencies

Comments on Compliance With Safety Standards:

OVERALL RATING of PERFORMANCE
(O)
(A)
(S)
(M)
(U)
(N/A)

Please provide any additional information you feel is important and not covered elsewhere in this evaluation:

Thank you for your remarks. Be sure to return to the Contracting Agency and not to the Contractor you are providing a reference for.

OFFEROR NAME___________________________

Respondent Signature ______________________________________Date Completed:_______________

File details come from the government source that posted it. Updated .