Specs_DLA_Standby_Generator_Pre-Alteration_Assessment_Report_-_Vol_1.pdf
PDF 5 MB Posted
- Attached to
- FY18 DLA Standby Generator Replacement
- Solicitation number
- W911XK18R0011
About this file
Attachment - Asbestos Assessment Vol 1
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PRE-ALTERATION ASSESSMENT FOR
ASBESTOS CONTAINING MATERIAL
AND LEAD BASED PAINT
For
EXP FEDERAL, INC.
DLA STANDBY GENERTOR REPLACMENT PROJECT
CONTRACT NUMBER: W9126G-11-D-0034
TASK ORDER: 0024
At
HART-DOLE-INOUYE FEDERAL CENTER
74 N. WASHINGTON STREET
BATTLE CREEK, MICHIGAN
Building 1 (MI0501BC) Building 4 (MI0507BC)
Building 1A (MI0502BC) Building 4A (MI0508BC)
Building 1B (MI0538BC) Building 5 (MI0509BC)
Building 2 (MI0503BC) Building 8 (MI0527BC)
Building 2A (MI504BC) Building 20 (MI0528BC)
Building 2B (MI0505BC)
Survey Date:
MARCH 13 – 16, 2017
Hygieneering Project #: 2017-3589-ENV
Report Date:
April 3, 2017
Prepared For:
exp Federal, Inc.
205 North Michigan Avenue, Suite 3800
Chicago, Illinois 60601-5941
Prepared By:
Hygieneering, Inc.
7575 Plaza Court
Willowbrook, Illinois 60527
Appendix A to Specification Section 02 82 13.00 10VOL 1
This page intentionally left blank
TABLE OF CONTENTS
INTRODUCTION Section 1
SCOPE OF WORK Section 2
SUMMARY OF FINDINGS Section 3
Asbestos
Lead Paint
METHODOLOGY Section 4
General References
General Organization
Visual Inspection
Homogeneous Material Categories
Condition Assessment of Suspect Material
Method of Analysis
DISCUSSION Section 5
WARRANTY Section 6
APPENDICES
Appendix A – Summary Tables Asbestos and Lead (Arranged by Building)
Table 1 – Summary of ACM Survey Results
Asbestos Analytical Results
Table 2 – Summary of Lead Survey Results
Lead Analytical Results
Appendix B – Sample and ACM Location Drawings
Appendix C – Photographs
Appendix D – Inspector Certifications
Appendix E – GSA Alteration Assessment Worksheet
Appendix F – Prior Asbestos and Lead-Based Paint Building Inspection Reports for Reference
This page intentionally left blank
Pre-Alteration Assessment for
DLA Standby Generator Project at
Hart-Dole-Inouye Federal Center, Battle Creek, MI
Hygieneering Project #: 2017-3589-ENV
SECTION 1
Introduction
Hygieneering, Inc. was retained by exp Federal, Inc. to conduct a pre-alteration assessment of suspect asbestos containing materials and suspect lead based paint to be disturbed by planned renovation activities at the Hart-Dole-Inouye Federal Center located at 74 N. Washington Street, in Battle Creek, Michigan. The pre-alteration assessment was conducted in support of the DLA Standby Generator
Replacement project at the facility.
The scope of the project extends through various portions within several of the individual buildings at the
Hart-Dole-Inouye Federal Center. The pre-alteration assessment was performed to identify suspect asbestos containing and suspect lead based paint materials which will be disturbed by planned demolition and renovation. The assessment also identified suspect materials within the work area which are present, but may not require removal or disturbance.
The following list highlights the building information for the Buildings (Building Reference Number) impacted by renovations:
• Building 1 (MI0501BC) • Building 4 (MI0507BC)
• Building 1A (MI0502BC) • Building 4A (MI0508BC)
• Building 1B (MI0538BC) • Building 5 (MI0509BC)
• Building 2 (MI0503BC) • Building 8 (MI0527BC)
• Building 2A (MI504BC) • Building 20 (MI0528BC)
• Building 2B (MI0505BC)
The scope of the survey included a review of proposed renovation work, a visual inspection to determine the presence and location of suspect asbestos containing materials and suspect lead based paint associated with the proposed system modifications and improvements. In addition, bulk samples from suspect asbestos containing materials and suspect lead based paint were collected and submitted for analysis by an accredited laboratory. Prior asbestos and lead based paint inspections provided by exp
Federal, Inc. and GSA, had been performed by TRC of Phoenix, Arizona in 2014. The prior inspections were referenced during the current pre-alteration assessment.
The on-site field work associated with the survey was conducted by Richard Zych and Chris Gatrel, of
Hygieneering, Inc. on March 13-16, 2017. Mr. Gabriel Gorsline, of exp Federal, Inc., provided escorted access to the facility and assisted with identification of areas and materials being impacted by the renovations.
Hart-Dole-Inouye Federal Center, Battle Creek, MI
SECTION 2
Scope of Work
The scope of asbestos and lead based paint assessment included portions of buildings at the Hart-Dole-
Inouye Federal Center, where proposed renovations to equipment and building components inside the buildings would be occurring. The scope of renovation work was determined from information outlined in the interim drawings titled “Hart-Dole-Inouye Federal Center, Battle, Creek MI, DLA Standby
Generator Replacement Contract Number W9126G-11-D-0034, Task Order 0024” dated 05/16/2016 by
US Army Corps of Engineers and exp Federal, Inc. Suspect materials within the renovation areas were identified. Prior survey reports were referenced for analytical results of prior testing. Additional sampling of materials not previously identified was also performed to identify the presence of asbestos or lead in materials being disturbed. Some suspect materials were presumed to be asbestos containing.
Areas outside of the intended scope were not assessed, and further assessment may be required, if the scope of renovations should change. The survey included identification of suspect materials that were accessible and visible. Exploratory demolition or the disassembly of active equipment was not performed as part of the inspection.
Bulk asbestos sampling was performed by an EPA accredited and State of Michigan Licensed asbestos building inspector and the samples collected were submitted to an accredited laboratory for analysis by polarized light microscopy (PLM). The building was occupied at the time of the surveys, and therefor energized equipment and systems were not dismantled. Analysis of bulk samples was performed by
EMSL Analytical, Inc.’s laboratory located at 4140 Litt Drive, in Hillside, Illinois, in accordance with the EPA Method 600/R-93/116, July 1993 utilizing polarized light microscopy (PLM) with a dispersion staining objective and by stereobinocular examination. These methods are based on the refractive index, optical properties and overall morphology of crystalline and non-crystalline substances. Additional analysis utilizing 400-point count method via PLM was also performed by EMSL Analytical, Inc.
laboratory where applicable.
The determination of lead present within paint on surfaces was completed by paint chip sampling of painted surfaces by an EPA accredited lead inspector/risk assessor and the submission of the paint chip samples to an accredited lab for analysis. Analysis of paint chip samples for lead was performed by
EMSL Analytical, Inc. located at 4140 Litt Drive, in Hillside, Illinois in accordance with the EPA
Method 3050B*/7000B, utilizing flame atomic absorption spectroscopy.
Hart-Dole-Inouye Federal Center, Battle Creek, MI
SECTION 3
Summary of Findings
Asbestos
Various forms of asbestos containing materials were found to be present within areas of proposed renovation. The attached Table 1 - Summary of ACM Survey Results summarizes the suspect asbestos materials identified within the affected renovation areas of the buildings at the Hart-Dole-Inouye Federal
Center, their location, analytical results and quantity of asbestos materials present.
Those materials which will be physically disturbed or removed during renovation included thermal duct insulation, thermal pipe insulation (various types), floor tile, flooring mastics, plaster ceilings, cement board panels, caulks and sealants. The attached summary tables and drawings highlight the locations of asbestos containing materials present within the work area., including those which may not be disturbed.
Limited internal components of electrical systems were visually inspected but not sampled. Electrical component arc chutes, circuit breaker housings and some wiring may be non-friable asbestos containing materials. These materials should be presumed to be asbestos containing. Following de-energization and removal of service, sampling may be performed prior to disposal to determine if asbestos is present.
The presence of asbestos containing materials within the affected work areas may require removal by trained and licensed asbestos workers in accordance with applicable federal, state and local regulations related to asbestos.
Lead Based Paint
Paint chip analysis utilizing flame atomic absorption for the sample collected inside the buildings was reported to have lead concentrations varying from below the analytical detection limit of 100 ppm up to
260,000 ppm lead. The attached Table 2 - Summary of Lead Paint Sampling Results summarizes the suspect lead based paint identified within the affected renovation areas of the buildings at the Hart-Dole-
Inouye Federal Center, their location, analytical results and condition. The majority of painted surfaces were in good condition. However, localized areas of painted surfaces exhibited visible signs of cracking, peeling and flaking paint.
The presence of lead within paint applied to surfaces being disturbed, may require removal, mitigation or disturbance of the painted surfaces be performed by licensed and/or properly trained lead workers in accordance with EPA and OSHA regulations for lead.
Hart-Dole-Inouye Federal Center, Battle Creek, MI
SECTION 3
Asbestos Survey Methodology
The purpose of this inspection was to identify, assess, inventory and provide approximate quantities of suspect ACM throughout each structure, facility component, or piece of equipment that is scheduled for potential renovation/demolition by exp Federal, Inc. and the building owner. The assessment and sampling procedures for asbestos were performed in general accordance with the guidelines published by the EPA in 40 CFR Part 763 Subpart E, October 30, 1987 (Asbestos Hazard Emergency Response Act -
AHERA). The U.S. EPA Guidance document 700/B-92/001, February 1992 and the OSHA Construction
Standard 1926.1101, August 10, 1994, requires an AHERA sampling scheme be followed for non-school buildings. Bulk sampling was also conducted and analysis performed by NVLAP accredited laboratory utilizing Polarized Light Microscopy to determine the presence or absence of asbestos in the identified suspect ACM.
General Organization
Before beginning the actual assessment, the inspector contacted the exp Federal, Inc. representative(s) to discuss the facility inspection, including access, preferred inspection and sampling times, sampling procedures, a review of construction drawings, and other access/safety issues.
The study itself consisted of three major activities - visual inspection, sampling and quantification.
Although these activities are listed separately, they are integrated tasks.
Visual Inspection
The visual inspection was performed by EPA accredited and State of Michigan licensed inspectors. An initial building walk-through was conducted to determine the presence and condition of suspect materials which were accessible and/or exposed. Materials which were similar in general appearance were grouped into homogeneous sampling areas based upon the period of construction or installation.
Homogeneous Material Categories (ACM)
A preliminary walk-through of the building was conducted to determine areas of materials which were visually similar in color, texture and general appearance, and which appeared to be installed at the same time. Such materials are deemed “homogeneous materials” by the EPA. During this walk-through, the locations of these homogeneous materials were also noted. Only materials which were accessible and/or exposed and suspected to contain asbestos were identified.
Following the EPA asbestos inspection protocol, each identified suspect homogeneous material was placed into one of the following EPA categories.
Surfacing: Any material sprayed or troweled onto building members.
Thermal System Insulation (TSI): Materials generally applied to various mechanical systems.
Miscellaneous: Any materials that do not fit either of the above categories.
Hart-Dole-Inouye Federal Center, Battle Creek, MI
Sampling Of Suspect Material (Asbestos)
Once the suspect ACM’s were categorized into one of the EPA ACM categories, the materials were sampled.
Suspect ACM’s were sampled by EPA accredited and State of Michigan licensed asbestos building inspectors. Representative samples of each type of major category of homogenous material were collected following EPA Purple Book protocol.
Historical data from prior building inspection was referenced during the asbestos assessment for analytical results. Not all suspect materials were sampled, and have been assumed to be asbestos containing.
Condition Assessment of Suspect Material (Asbestos)
An assessment of each suspect ACM was performed to provide the necessary information to develop appropriate response actions/recommendations. The condition, quantity, location, type and extent of damage was evaluated to prioritize each ACM into one of the three following priorities for response:
• (SD) Significantly Damaged - ACM shows damage or high potential for damage and should be removed or repaired as soon as possible to prevent exposure to asbestos.
• (D) Damaged - ACM shows signs of damage due to age, deterioration, or physical contact with potential for further damage. The ACM should be repaired or removed if the physical condition changes or if renovation or building operations will disturb the material.
• (PD) Potential for Damage - ACM shows little to no damage with a low potential for additional damage. Maintain the ACM in its current condition through an Operations and Maintenance
Program. Periodically monitor the ACM for damage.
• (G) Good Condition – ACM shows little to no damage and is in generally good condition, maintain
ACM in its current condition through the Operations and Maintenance Program. Periodically monitor the ACM for damage.
Quantification
Quantities of accessible and/or exposed building materials that were suspected of containing asbestos were estimated. This estimation was performed by taking approximate measurements in the field and reviewing available drawings. Suspect materials applied to surfaces such as floors, walls and ceilings were expressed in total square footage. All measurements should be quantified by qualified abatement contractors prior to submitting any bids for abatement and/or repair.
The quantification of identified concealed asbestos containing materials (i.e. flange gaskets) was based upon the presumption that the same construction materials and applications were utilized throughout the structure.
Method of Analysis
Analysis was performed via macroscopic observation and slide preparation(s) for microscopic examination and identification purposes. The samples were mounted on slides and then analyzed for asbestos (chrysotile, amosite, crocidolite, anthophyllite and actinolite/ tremolite), fibrous non-asbestos
Hart-Dole-Inouye Federal Center, Battle Creek, MI constituents (mineral wool, paper, etc.) and nonfibrous constituents. Asbestos was identified by refractive indices, morphology, color, pleochroism, birefringence, extinction characteristics and signs of elongation. The same characteristics were used to identify the non-asbestos constituents. The microscopist visually estimated relative amounts of each constituent by determining the volume of each constituent in proportion to the total volume of the sample, using a stereoscope.
Bulk samples were analyzed by Polarized Light Microscopy (PLM) with dispersion staining as described by the interim method of analysis in optical mineralogy and the currently accepted methods for the determination of asbestos in bulk samples. A suspect material is immersed in a solution of known refractive index and subjected to illumination by polarized light. The characteristic color displays which result enable mineral identification.
Further analysis of friable asbestos containing materials reported to contain less than 10% asbestos was conducted in accordance with EPA guidelines. EPA recommended PLM analysis with quantification by
400-point count was performed.
It should be noted that some asbestos containing building materials may not be accurately identified and/or quantified by PLM. As an example, the original fabrication of vinyl floor tiles routinely involved milling of asbestos fibers to extremely small sizes. As a result, these fibers may go undetected under the standard polarized light microscopy method. The EPA recommends Transmission Electron Microscopy
(TEM) for a more definitive analysis of these materials (Federal Register Vol. 59. No. 146/August 1, 1994).
Multi-layered materials, such as plasters and floor tiles with mastic, were analyzed and reported by layers
(Federal Register Vol. 59. No. 3, January 5, 1994).
Lead Paint Survey Methodology
Note that, the survey conducted at the building was not a comprehensive HUD survey for the presence of lead based paint within the facility. Where applicable, representative sampling of suspected lead based paints or coatings was performed to determine the presence and concentration of lead in paints/coatings that will be disturbed during renovation and/or surfaces that had paint in poor condition within the proposed work area. During the inspection, a visual assessment of general condition of the painted surface was also conducted.
Historical data from prior building inspection was referenced during the lead paint assessment. The assessment was performed by EPA accredited lead inspector/risk assessor.
Appendix A – Summary Tables Asbestos and Lead (Arranged by Building)
Table 1 – Summary of ACM Survey Results
Asbestos Analytical Results
Table 2 – Summary of Lead Survey Results
Lead Analytical Results
Table 1
Summary of ACM Survey Results
Client: exp Federal, Inc. Building Name: Building 1 at Hart-Dole-Inouye Federal Center
Location: 74 N. Washington Ave., Battle Creek, Michigan Hygieneering Project #: 2017-3589-ENV
Material Type Legend: Material Condition Assessment Legend:
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Material Description Material Location Homogeneous
Area
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
Corrugated Paper Pipe
Length Insulation
Miscellaneous Pipes within
Mechanical Room 1-B-1A
1-TPA PD F
Y
Assumed
35 LF T
Mudded Fittings on
Corrugated Paper Pipe
Length Insulation
Miscellaneous Pipes within
Mechanical Room 1-B-1A
1-TJA
(HA:68)
PD F
Y
Previously
Identified
60% chrysotile
6 LF T
Cementitious Block Pipe
Length Insulation
Steam Header and
Miscellaneous Pipes within
Mechanical Room 1-B-1A
1-TPB
(HA:42 & 70)
PD F
Y
Previously
Identified
40-45% chrysotile
120 LF T
Mudded Fittings on
Cementitious Block Pipe
Length Insulation
Steam Header and
Miscellaneous Pipes within
Mechanical Room 1-B-1A
1-TJB
(HA:68)
D F
Y
Previously
Identified
60% chrysotile
~30 LF T
Table 2
Summary of Lead Sampling Results
Client: exp Federal, Inc. Building Name: Building 1 – Hart-Dole-Inouye
Federal Center
Location:
74 N. Washington Ave., Battle Creek, Michigan
Hygieneering Project #:
2017-3589-ENV
ppm = Parts Per Million (mg/Kg = ppm) HUD Guidelines (1996 Revision) = 5000 ppm Reporting Limit = 100 ppm
CPSC Level = 600 ppm (100 ppm = 0.01 % by wt.)
* According to OSHA there are no threshold levels for lead content.
Material Description Location Sample
Number
Analytical
Result (ppm)
Condition
Light Blue Paint on Walls Basement Machine Room in Building #1 1B-W-01 31,000 ppm Intact
EMSL Analytical, Inc.
4140 Litt Drive Hillside, IL 60162
Tel/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
261702172EMSL Order:
Customer ID: HYGI55
Customer PO:
Project ID:
Attention: Phone:Rich Zych (630) 742-1545
Fax:Hygieneering, Inc. (630) 789-3813
Received Date:7575 Plaza Court 03/17/2017 4:40 PM
Analysis Date:Willowbrook, IL 60527 03/21/2017
Collected Date:
Project: 2017-3589-ENV/ HDI BLDG # 1B
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1B-MMA-1
261702172-0001
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMA-2
261702172-0002
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMA-3
261702172-0003
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMB-1
261702172-0004
5% ChrysotileNon-fibrous (Other)95%Tan
Non-Fibrous
Homogeneous
CREAM /BEIGE
HARD CAULK
1B-MMB-2
261702172-0005
Positive Stop (Not Analyzed)CREAM /BEIGE
HARD CAULK
1B-MMB-3
261702172-0006
Positive Stop (Not Analyzed)CREAM /BEIGE
HARD CAULK
Analyst(s)
Christine Stouffer (4) James Hahn, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Hillside, IL NVLAP Lab Code 200399-0
Initial report from: 03/21/2017 11:34:03
Page 1 of 1ASB_PLM_0008_0001 - 1.78 Printed: 3/21/2017 10:34 AM
Client: exp Federal, Inc. Building Name: Building 1A – Hart-Dole-Inouye Federal Center
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
4” Black Basecove &
Adhesive
Walls in Room 1A-SB-13 and 1A-SB-14
1A-MBA
(HA: 25)
G NF
N
Previously Identified N/A M
2’ x 4’ Dot and Fissure
Ceiling Tile with Pattern
(Labeled with “Danger”-
Asbestos Warning Labels)
Ceiling in Basement Level
Former Data Center Rooms
1A-B-9, and Presumed in
Rooms 1A-B-11 & 1A-B-13
(Secured Areas - Restricted
Access)
1A-MCA G F N N/A M
2’ x 2’ Dot and Gouge
Recessed Ceiling Tile
Ceiling in Storage Room
1A-SB-14
1A-MCB
(HA: 09)
G F
N
Previously Identified N/A M
Brown and Black Adhesive on Terrazzo
On Terrazzo Beneath
Raised Floor of Data
Center Room 1A-B-9, and
Presumed in Rooms 1A-B-
11 & 1A-B-13 (Secured
Areas - Restricted Access)
1A-MFA G NF
Y
2% Chrysotile
5,500 SF M
Dark Brown Fibrous Pipe
Sleeve Backer
Wall Sleeve Between Rooms
1A-SB 13 and 1A-SB-14
1A-MGA PD F N N/A M
Black Tar Sealant on Wall
Overhead on Wall Above
Lower Ceiling Line in
Room 1A-SB-13
1A-MMA G NF
Y
4% Chrysotile
2 SF M
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
Tan Pedestal Adhesive
On Terrazzo Beneath Raised
Floor of Data Center Room
1A-B-9, and Presumed in
Rooms 1A-B-11 & 1A-B-13
(Secured Areas - Restricted
Access)
1A-MMB G NF N N/A M
Tan Over Black Residual
Pedestal Adhesive
On Terrazzo Beneath Raised
Floor of Data Center Room
1A-B-9, and Presumed in
Rooms 1A-B-11 & 1A-B-13
(Secured Areas - Restricted
Access)
1A-MMC G NF N N/A M
Flex Cement Board Panels
(Transite)
Sub-Basement Corridor on
Plaster Above Chilled
Water Piping South of
Stair #1
1A-MTA G NF Assumed 30 SF M
Drywall Tape and Joint
Compound
Walls of Storage Area in
Room 1A-SB-14
1A-MWA D F
Y
Assumed
120 SF M
1’ x 1’ Large Fissure
Acoustic Wall Tile and
Brown Mastic
Wall in Room 1A-G-18 &
1A-G-20
1A-MWB
(HA: 68)
G F/NF
N
Previously Defined N/A M
White Paint Over Gray
Coating on Concrete
Foundation Walls of Rooms
1A-SB-13 & 1A-SB-14
1A-SCA G F N N/A S
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
White Plaster Over Gray
Scratch Coat
Ceilings in Sub-Basement
Corridor and Rooms 1A-SB-
01, 1A-SB-02 & 1A-SB-04
1A-SPA G F N N/A S
Cementitious Block
Compound and Wire Mesh
Duct Insulation
Ductwork Along Est Side of Room 1A-SB-01; and
Section of Ductwork in
Corridor at Wall North of
Room 1A-SB-03
1A-TDA PD F
Y
2.25% Amosite
160 SF T
Mudded Fittings on White and Gray Cementitious
Block Pipe Length
Insulation
Piping in Rooms 1A-SB-04, 1A-SB-13, 1A-SB-14, 1A-
SB-15 and Sub-Basement
Corridors and Basement
Tunnel
1A-TJA
(HA: 106)
D F
Y Previously Identified
30% Chrysotile, 5% Amosite
25 LF T
Cementitious Fittings on
Fiberglass Pipe Length
Miscellaneous Piping in
Rooms 1A-SB-01, 1A-SB-
04, 1A-SB-14, 1A-SB-15
and Sub-Basement
Corridors and Basement
Tunnel
1A-TJB G F
Y
Assumed
~20 LF T
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
Mudded Fittings on
Layered Paper Pipe
Length Insulation
Miscellaneous Pipes in
Room 1A-SB-01 and
Extending into Corridor;
Pips Along ceiling in
Corridor South of Stair #1 in Sub-Basement; Pipes in
Ceiling Cavity of Data
Center Room 1-B-9
1A-TJE PD F
Y
5% Amosite
3% Chrysotile
~30 LF T
Woven Canvas Wrapped
Mudded Fitting
Compound on Fiberglass
Pipe Insulation
Chilled Water Piping in
Sub-Basement in Sub-
Basement Mechanical
Rooms, Corridors, and
Tunnel in Basement
1A-TJF PD F
Y
Assumed
~20 LF T
White and Gray
Cementitious Block Pipe
Length Insulation
Piping in Rooms 1A-SB-04, 1A-SB-13, 1A-SB-14, 1A-
SB-15 and Miscellaneous
Corridors and Basement
Tunnel
1A-TPA
PD F
Y
Assumed
150 LF T
Cork Pipe Length Insulation
Pipes Along Ceiling and in
Walls of Rooms 1A-SB-13 and 1A-SB-14, Water Piping in Corridor and Room 1A-
SB-01
1A-TPC D F N N/A T
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
Corrugated Paper Pipe
Length Insulation
Pipes Along Ceiling of
Room 1A-SB-14; at North
Wall of Room 1A-SB-04;
and in Mechanical Rooms
1A-Sb-01 & 1A-SB-15
1A-TPD PD F
Y
Previously Identified
30% Chrysotile
120 LF T
Layered Paper Pipe
Insulation
Miscellaneous Pipes in
Room 1A-SB-01 and
Extending into Corridor;
Pipes Along ceiling in
Corridor South of Stair #1 ibn Sub-Basement; Pipes in
Ceiling Cavity of Data
Center Room 1-B-9
1A-TPE D F
Y
6.25% Chrysotile
200 LF T
Tel/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
261702166EMSL Order:
Customer ID: HYGI55
Customer PO:
Project ID:
Attention: Phone:Rich Zych (630) 742-1545
Fax:Hygieneering, Inc. (630) 789-3813
Received Date:7575 Plaza Court 03/17/2017 4:40 PM
Analysis Date:Willowbrook, IL 60527 03/21/2017
Collected Date:
Project: 2017-3589-ENV/ HDI BLDG # 1A
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1A-MCA-1
261702166-0001
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
30%
60%
White
Non-Fibrous
Homogeneous
SUSP. CT 2X4 DOT
& FISSURE
1A-MCA-2
261702166-0002
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
30%
60%
White
Fibrous
Homogeneous
SUSP. CT 2X4 DOT
& FISSURE
1A-MCA-3
261702166-0003
None DetectedNon-fibrous (Other)10%Cellulose
Min. Wool
30%
60%
Tan/White
Fibrous
Homogeneous
SUSP. CT 2X4 DOT
& FISSURE
1A-MFA-1
261702166-0004
2% ChrysotileNon-fibrous (Other)98%Black
Non-Fibrous
Homogeneous
BLACK MASTIC
(RESIDUAL)
1A-MFA-2
261702166-0005
Positive Stop (Not Analyzed)BLACK MASTIC
(RESIDUAL)
1A-MFA-3
261702166-0006
Positive Stop (Not Analyzed)BLACK MASTIC
(RESIDUAL)
1A-MGA-1
261702166-0007
None DetectedNon-fibrous (Other)10%Cellulose90%Brown
Fibrous
Homogeneous
BROWN FIBROUS
MATERIAL
1A-MMA-1
261702166-0008
4% ChrysotileNon-fibrous (Other)96%Black
Non-Fibrous
Homogeneous
BLACK SEALANT
1A-MMA-2
261702166-0009
Positive Stop (Not Analyzed)BLACK SEALANT
1A-MMA-3
261702166-0010
Positive Stop (Not Analyzed)BLACK SEALANT
1A-MMB-1
261702166-0011
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
TAN ADHESIVE
1A-MMB-2
261702166-0012
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
TAN ADHESIVE
1A-MMB-3
261702166-0013
None DetectedNon-fibrous (Other)100%Tan
Non-Fibrous
Homogeneous
TAN ADHESIVE
1A-MMC-1
261702166-0014
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
TAN/CREAM OVER
BLACK ADHESIVE
Materials are inseperable.
1A-MMC-2
261702166-0015
None DetectedNon-fibrous (Other)100%Tan/Black
Non-Fibrous
Homogeneous
TAN/CREAM OVER
BLACK ADHESIVE
1A-MMC-3
261702166-0016
None DetectedNon-fibrous (Other)100%Black/Yellow
Non-Fibrous
Homogeneous
TAN/CREAM OVER
BLACK ADHESIVE
Initial report from: 03/21/2017 16:03:22
Page 1 of 3ASB_PLM_0008_0001 - 1.78 Printed: 3/21/2017 3:03 PM
Tel/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
261702166EMSL Order:
Customer ID: HYGI55
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1A-SCA-1
261702166-0017
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE OVER GRAY
COATING
1A-SCA-2
261702166-0018
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE OVER GRAY
COATING
1A-SCA-3
261702166-0019
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE OVER GRAY
COATING
1A-SPA-1-Skim Coat
261702166-0020
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-1-Base Coat
261702166-0020A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-2-Skim Coat
261702166-0021
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-2-Base Coat
261702166-0021A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-3-Skim Coat
261702166-0022
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-3-Base Coat
261702166-0022A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-4-Skim Coat
261702166-0023
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-4-Base Coat
261702166-0023A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-5-Skim Coat
261702166-0024
None DetectedNon-fibrous (Other)100%White
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-SPA-5-Base Coat
261702166-0024A
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
WHITE PLASTER &
GRAY SCRATCH
COAT
1A-TDA-1
261702166-0025
5% AmositeNon-fibrous (Other)95%White
Non-Fibrous
Homogeneous
OFF-WHITE
CEMENTITIOUS
INSULATION CMPD
1A-TDA-2
261702166-0026
Positive Stop (Not Analyzed)OFF-WHITE
CEMENTITIOUS
INSULATION CMPD
1A-TDA-3
261702166-0027
Positive Stop (Not Analyzed)OFF-WHITE
CEMENTITIOUS
INSULATION CMPD
1A-TJE-1
261702166-0028
5%
3%
Amosite
Chrysotile
Non-fibrous (Other)92%Brown/Gray
Fibrous
Homogeneous
CEMENTITIOUS
FITTING CMPD
1A-TJE-2
261702166-0029
Positive Stop (Not Analyzed)CEMENTITIOUS
FITTING CMPD
1A-TJE-3
261702166-0030
Positive Stop (Not Analyzed)CEMENTITIOUS
FITTING CMPD
Page 2 of 3ASB_PLM_0008_0001 - 1.78 Printed: 3/21/2017 3:03 PM
Tel/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
261702166EMSL Order:
Customer ID: HYGI55
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1A-TPC-1
261702166-0031
None DetectedNon-fibrous (Other)40%Cellulose60%Brown
Fibrous
Homogeneous
BLACK TAR COATED
CORK INSULATION
1A-TPC-2
261702166-0032
None DetectedNon-fibrous (Other)40%Cellulose60%Brown
Non-Fibrous
Homogeneous
BLACK TAR COATED
CORK INSULATION
1A-TPC-3
261702166-0033
None DetectedNon-fibrous (Other)40%Cellulose60%Brown/Black
Fibrous
Homogeneous
BLACK TAR COATED
CORK INSULATION
1A-TPE-1
261702166-0034
3% ChrysotileNon-fibrous (Other)97%Brown
Fibrous
Homogeneous
MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
1A-TPE-2
261702166-0035
Positive Stop (Not Analyzed)MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
1A-TPE-3
261702166-0036
Positive Stop (Not Analyzed)MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
Analyst(s)
Brian Jolly (22)
Christine Stouffer (9)
James Hahn, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Hillside, IL NVLAP Lab Code 200399-0
Page 3 of 3ASB_PLM_0008_0001 - 1.78 Printed: 3/21/2017 3:03 PM
Phone/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
EMSL Order: 261702166
Customer ID: HYGI55
Customer PO:
Project ID:
Attention: Rich Zych Phone: (630) 742-1545
Hygieneering, Inc. Fax: (630) 789-3813
7575 Plaza Court Received: 03/17/2017 4:40 PM
Willowbrook, IL 60527 Analysis Date: 03/27/2017 - 03/28/2017
Collected:
Project: 2017-3589-ENV/ HDI BLDG # 1A
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using
Polarized Light Microscopy. Quantitation using 400 Point Count Procedure
Sample Description Appearance % Fibrous % Non-Fibrous % Type
Non-Asbestos Asbestos
White
Non-Fibrous
Homogeneous
OFF-WHITE
CEMENTITIOUS
INSULATION CMPD
1A-TDA-1
261702166-0025
Non-fibrous (Other)97.75% 2.25%Amosite
Brown
Non-Fibrous
Homogeneous
MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
1A-TPE-1
261702166-0034
Non-fibrous (Other)99.25% 0.75%Chrysotile
Brown
Fibrous
Homogeneous
MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
1A-TPE-2
261702166-0035
Non-fibrous (Other)93.75% 6.25%Chrysotile
MULTI-TAN & BLACK
LAYERED PIPE
INSULATION
1A-TPE-3
261702166-0036
Positive Stop
(Not Analyzed)
Analyst(s)
Brian Jolly (3) James Hahn, Laboratory Manager or other approved signatory
Disclaimer:Some samples may contain asbestos fibers present in dimensions below PLM resolution limits. The limit of detection as stated in the method is 0.25%. EMSL Analytical Inc suggests that samples reported as <0.25% or none detected undergo additional analysis via TEM . The above test report relates only to the items tested. This report may not be reproduced, except in full, without written approval of EMSL Analytical Inc. This test report must not be used by the client to claim product endorsement by NVLAP or any agency of the United States Government . EMSL
Analytical Inc., bears no responsibility for sample collection activities, analytical method limitations, or the accuracy of results when requested to separate layered samples. EMSL Analytical
Inc., liability is limited to the cost of sample analysis.The test results contained within this report meet the requirements of NELAC unless otherwise noted. Samples received in good condition unless otherwise noted. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Samples analyzed by EMSL Analytical, Inc. Hillside, IL NVLAP Lab Code 200399-0
Report amended: 03/28/2017 08:56:44 Replaces amended report from: 03/28/2017 08:52:30 Reason Code: Client-Samples Added
ASB_PLMPC_0006_0002 Printed 3/28/2017 10:10:07AM Page 1 of 1
Client: exp Federal, Inc. Building Name: Building 1A – Hart-Dole-Inouye
CPSC Level = 600 ppm (100 ppm = 0.01 % by wt.)
* According to OSHA there are no threshold levels for lead content.
Material Description Location Sample
Number
Analytical
Result (ppm)
Condition
White Paint on Plaster
Ceiling 1A Sub-Basement Corridor 1A-C-01 520 ppm
Localized
Peeling
White Paint on Plaster
Ceiling 1A-SB-01 Ceilings 1A-C-02 120 ppm Peeling
Cream Paint on Ductwork 1A-SB-14 Duct at Ceiling 1A-D-01 1,400 ppm Cracking, Peeling
Brown and Red Paint on
Concrete Floor
Floor in Room 1A-SB-01 by
Switchgear 1A-FLR-1 950 ppm Intact
Gray Epoxy Over Red Paint on Concrete
Bldg. 1A Tunnel Corridor
Floor 1A-FLR-2 1,200 ppm
Localized
Moisture
Damage, Peeling
Gray Epoxy Over Red Floor
Paint
Bldg. 1A Tunnel Corridor
Floor 1A-FLR-3 450 ppm
Localized
Moisture
Damage, Peeling
Silver Paint on Conduit Pipe 1A-SB-14 North Wall 1A-P-01 650 ppm Minor Corrosion
Red Over White Paint on
Sprinkler
Corridor Outside 1A-SB-
1A-P-02 6,100 ppm Intact
Cream Paint on Brick Wall Walls in Room 1A-SB-14 1A-W-01 440 ppm Cracking, Water
Damage
Cream Paint on Concrete North Wall and Columns of Room 1A-SB-14 1A-W-02 66,000 ppm
Cracking, Peeling, Water
Damage
White Over Gray Coating on Concrete Wall
North and East Walls of
Room 1A-SB-14 1A-W-03 140 ppm Intact
Light Blue Green Paint on
Concrete and CMU Walls of Room 1A-SB-01 1A-W-04 200 ppm Intact
Client Sample Description ConcentrationLab ID Analyzed Lead
Collected
EMSL Analytical, Inc.
4140 Litt Drive, Hillside, IL 60162 Phone/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com chicagolab@emsl.com
Attn: Rich Zych Hygieneering, Inc.
7575 Plaza Court Willowbrook, IL 60527
Received: 03/17/17 4:40 PM
2017-3589-ENV/ HDI BLDG # 1A
Fax: (630) 789-3813 Phone: (630) 654-2550
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
261702145 CustomerID: HYGI55 CustomerPO:
ProjectID:
EMSL Order:
Site: WHITE & TAN PAINT ON CEILING 261702145-00011A-C-01 520 ppm3/21/2017
Site: WHITE PAINT ON CEILING 261702145-00021A-C-02 120 ppm3/21/2017
Site: OFF WHITE & TAN PAINT ON DUCT WORK 261702145-00031A-D-01 1400 ppm3/21/2017
Site: SILVER GRAY PAINT ON PIPE 261702145-00041A-P-01 650 ppm3/21/2017
Site: RED OVER WHITE ON SPRINKLER PIPE 261702145-00051A-P-02 6100 ppm3/21/2017
Site: LAYERED OFF WHITE PAINT 261702145-00061A-W-01 440 ppm3/21/2017
Site: WHITE OVER GRAY PAINT ON WALL 261702145-00071A-W-02 66000 ppm3/21/2017
Site: WHITE PAINT FROM WALL 261702145-00081A-W-03 140 ppm3/21/2017
Site: LIGHT BLUE OVER WHITE PAINT ON WALL 261702145-00091A-W-04 200 ppm3/21/2017
Site: LIGHT GRAY & RED FLOOR COATING 261702145-00101A-FLR-1 950 ppm3/21/2017
Site: GRAY OVER RED FLOOR COATING 261702145-00111A-FLR-2 1200 ppm3/21/2017
Site: GRA EPOXY RED FLOOR PAINT 261702145-00121A-FLR-3 450 ppm3/21/2017
Lisa Odeshoo, Lead Lab Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 3/21/2017 3:37:24 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Hillside, IL AIHA-LAP, LLC--ELLAP Accredited #102992
Initial report from 03/21/2017 15:37:24 http://www.EMSL.com mailto:chicagolab@emsl.com
Client: exp Federal, Inc. Building Name: Building 1B – Hart-Dole-Inouye Federal Center
S = Surfacing Materials (spray or trowel applied building members) (G) Good Condition, Monitor Condition T = Thermal System Insulation (materials generally applied to various mechanical systems) (PD) Potential for Damage, Monitor Condition, Repair or Remove as Necessary
M = Miscellaneous Materials (any materials which do not fit either of the above categories) (D) Damage Material, Remove or Repair as Necessary, Monitor Condition
Friability: (F) = Friable (NF) = Non-Friable (SD) Significantly Damaged, Removal or Replacement Recommended
Designation
Material
Condition
F/
NF
Analytical Result
(Asbestos Present
Y or N)
Estimated
Quantity
Material
Type
Mudded Fittings Associated with Fiberglass Pipe Length
Insulation
Heating Supply Piping along
Ceiling and Feeding AHUs in
Tunnel and Fan Room 1B-
SB-15
1B-TJA
(HA: 23)
G F
N
Previously Reported
None Detect
N/A T
Red Rubberized Vibration
Pads
Mounting Pads from Former
AHU on Concrete Slab in
Room 1B-SB-15
1B-MMA G NF N N/A M
Hard Tan Sealant
Residual on Concrete Pad and on Wall at Former
AHU Room 1B-SB-15
1B-MMB G NF
Y
5% Chrysotile
4 SF M
Tel/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com / chicagolab@emsl.com
261702172EMSL Order:
Customer ID: HYGI55
Customer PO:
Project ID:
Attention: Phone:Rich Zych (630) 742-1545
Fax:Hygieneering, Inc. (630) 789-3813
Received Date:7575 Plaza Court 03/17/2017 4:40 PM
Analysis Date:Willowbrook, IL 60527 03/21/2017
Collected Date:
Project: 2017-3589-ENV/ HDI BLDG # 1B
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
1B-MMA-1
261702172-0001
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMA-2
261702172-0002
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMA-3
261702172-0003
None DetectedNon-fibrous (Other)100%Red
Non-Fibrous
Homogeneous
RED/ORANGE
RUBBER CMPD
1B-MMB-1
261702172-0004
5% ChrysotileNon-fibrous (Other)95%Tan
Non-Fibrous
Homogeneous
CREAM /BEIGE
HARD CAULK
1B-MMB-2
261702172-0005
Positive Stop (Not Analyzed)CREAM /BEIGE
HARD CAULK
1B-MMB-3
261702172-0006
Positive Stop (Not Analyzed)CREAM /BEIGE
HARD CAULK
Analyst(s)
Christine Stouffer (4) James Hahn, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . This report relates only to the samples reported and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. Interpretation and use of test results are the responsibility of the client. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government . Non-friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis. Samples received in good condition unless otherwise noted. Estimated accuracy, precision and uncertainty data available upon request. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Reporting limit is 1%
Samples analyzed by EMSL Analytical, Inc. Hillside, IL NVLAP Lab Code 200399-0
Initial report from: 03/21/2017 11:34:03
Page 1 of 1ASB_PLM_0008_0001 - 1.78 Printed: 3/21/2017 10:34 AM
Client: exp Federal, Inc. Building Name: Building 1B – Hart-Dole-Inouye
Analytical
Result (ppm)
Condition
White Paint on Ceiling Mechanical Room 1B-SB-
15 Ceiling 1B-C-01 <120 ppm Intact
Greenish Gray Over Gray
Paint
Mechanical Room 1B-SB-
15 Floor 1B-FLR-01 <100 ppm Intact
Light Blue Paint on Walls
Machine Room in Building
#1 Basement
(Room 1-B-14)
1B-W-01 31,000 ppm Intact
Beige Over Light Green
Olive on Yellow Over
White on Plaster
Corridor 1B-W-02 210 ppm Minor Contact
Damage
Collected
EMSL Analytical, Inc.
4140 Litt Drive, Hillside, IL 60162 Phone/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com chicagolab@emsl.com
Attn: Rich Zych Hygieneering, Inc.
7575 Plaza Court Willowbrook, IL 60527
Received: 03/17/17 4:40 PM
2017-3589-ENV/ HDI-BLDG # 1B
Fax: (630) 789-3813 Phone: (630) 654-2550
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
261702141 CustomerID: HYGI55 CustomerPO:
ProjectID:
EMSL Order:
Site: WHITE OVER TAN CEILING PAINT 261702141-00011B-C-01* <120 ppm3/21/2017
Site: LIGHT GRAY FLOOR FINISH 261702141-00021B-FLR-01 <100 ppm3/21/2017
Site: BEIGE, LIGHT GREEN, GRAY & TAN LAYERED PAINT 261702141-00031B-W-02 210 ppm3/21/2017
Site: LIGHT BLUE PAINT 261702141-00041B-W-01 31000 ppm3/21/2017
Data reported may not reach applicable analytical sensitivity due to insufficient sample weights submitted. Suggested weight for analysis is 0.2 g.
Lisa Odeshoo, Lead Lab Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 3/21/2017 3:20:31 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.010 % wt based on the minimum sample weight per our SOP. Unless noted, results in this report are not blank corrected. This report relates only to the samples reported above and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities. Samples received in good condition unless otherwise noted. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. The QC data associated with the sample results included in this report meet the recovery and precision requirements unless specifically indicated otherwise.
Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Hillside, IL AIHA-LAP, LLC--ELLAP Accredited #102992
Initial report from 03/21/2017 15:20:31
Client: exp Federal, Inc. Building Name: Building 1C – Hart-Dole-Inouye
74 N. Washington Ave., Battle
Creek, Michigan
Analytical
Result (ppm)
Condition
Cream Paint on Ceiling and
Conduit Basement Vault Ceiling 1C-C-1 2,000 ppm
Ceiling Good, Conduit Cracked
Shiny Gray Epoxy Over
Light Gray Paint Basement Vault Floor 1C-FLR-1 <100 ppm Floor Peeling
Greenish Gray Paint on
Wall Basement Vault Walls 1C-W-1 1,800 ppm
Good, Localized
Peeling
Collected
EMSL Analytical, Inc.
4140 Litt Drive, Hillside, IL 60162 Phone/Fax: (773) 313-0099 / (773) 313-0139 http://www.EMSL.com chicagolab@emsl.com
Attn: Rich Zych Hygieneering, Inc.
7575 Plaza Court Willowbrook, IL 60527
Received: 03/17/17 4:40 PM
2017-3589-ENV/ HDI BLDG # 1C
Fax: (630) 789-3813 Phone: (630) 654-2550
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
261702143 CustomerID: HYGI55 CustomerPO:
ProjectID:
EMSL Order:
Site: WHITE PAINT ON CEILING 261702143-00011C-C-1 2000 ppm3/21/2017
Site: GRAY EPOXY FLOOR COATING 261702143-00021C-FLR-1 <100 ppm3/21/2017
Site: GREENISH GRAY OVER WHITE PAINT ON WALL 261702143-00031C-W-1 1800 ppm3/21/2017
Lisa Odeshoo, Lead Lab Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 3/21/2017 3:23:48 PM
*Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA.
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it.