W911XK-09-B-0006 Amendment 0001 - Project Sign & Safety Sign.pdf

PDF 183 KB Posted

Attached to
RECOVERY--Z--Sturgeon Bay South Revetment Repair, Section N, Sturgeon Bay, Wisconsin
Solicitation number
W911XK-09-B-0006
Issued by

About this file

Project Sign & Safety Sign requirements

View the file

Other files

File Type Posted
W911XK-09-B-0006 Sturgeon Bay Repair - Bid Abstract.pdf PDF
W911XK-09-B-0006 Amendment 0005 conform.pdf PDF
W911XK-09-B-0006 Amendment 0005 SF30.pdf PDF
W911XK-09-B-0006 Questions & Answers 12 June.pdf PDF
W911XK-09-B-0006 Amendment 0005 SF30.pdf PDF
W911XK-09-B-0006 Amendment 0005 conform.pdf PDF
14stbay_AMEND_5JUN09.pdf PDF
03stbay_AMEND_5JUN09.pdf PDF
09stbayAMEND_5JUN09.pdf PDF
16STBAY_AMEND_5JUN09.pdf PDF
W911XK-09-B-0006 Questions & Answers 9 June.pdf PDF
W911XK-09-B-0006 Amendment 0004 SF 30.pdf PDF
W911XK-09-B-0006 Amendment 0004 Conform.pdf PDF
W911XK-09-B-0006 Questions & Answers 2 June.pdf PDF
W911XK-09-B-0006 Questions & Answers 29 May.pdf PDF
W911XK-09-B-0006 Amendment 0003 SF30.pdf PDF
W911XK-09-B-0006 Amendment 0003 conform.pdf PDF
W911XK-09-B-0006 Questions & Answers 27 May.pdf PDF
W911XK-09-B-0006 Amendment 0002.pdf PDF
W911XK-09-B-0006 Questions & Answers 22 May.pdf PDF
AMEND0001.maxFR —
W911XK-09-B-0006 Amendment 0001.pdf PDF
09stbayAMEND0001.cal —
09stbayAMEND0001.maxTK —
12stbay.cal —
W911XK-09-B-0006 Solicitation.pdf PDF
14stbay.cal —
09stbay.cal —
02stbay.cal —
16STBAY.cal —
13stbay.cal —
01stbay.cal —
05stbay.cal —
11stbay.cal —
08stbay.cal —
10stbay.cal —
07stbay.cal —
SVDTITLE.CAL —
W911XK-09-B-0006 Specifications.pdf PDF
06stbay.cal —
04stbay.cal —
entry.maxFR —
plans.maxfr.maxFR —
03stbay.cal —
15STBAY.cal —
Show all 45

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADD SECTION 01 58 01 PROJECT SIGN AND SAFETY SIGN

SECTION 01 58 01

PROJECT SIGN AND SAFETY SIGN

05/09

PART 1 GENERAL

1.1 SCOPE

The work covered by this Section consists of providing the fabrication, erection and maintenance of one (1) Project Identification Sign and one

(1) Safety Performance Sign. The items furnished in accordance with this Section shall be furnished within 10 calendar days after Notice to Proceed and shall be maintained in good condition throughout the construction period. All items will remain the property of the Contractor and shall be removed at the end of the contract.

1.2 SUBMITTALS

Government approval is required for submittals with a "G" designation;

submittals not having a "G" designation are for information only or as otherwise designated. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. The following shall be submitted in accordance with Section

01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Sign Layouts; G-AOF.

Submit the proposed layouts before production.

1.3 APPLICABLE PUBLICATIONS

The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.

U.S. ARMY CORPS OF ENGINEERS (USACE)

EP 310-1-6 Graphic Standards Manual

EP 310-6a Sign Standards Manual

EP 310-6b Sign Standards Manual

1.4 PAYMENT

No separate or direct payment will be made for the items listed in this Section, and such work will be considered as a subsidiary obligation of the Contractor.

PART 2 PRODUCTS

2.1 CONSTRUCTION PROJECT SIGNS

a. Construction project signs shall be coordinated with the Contracting Officer. The signs include one (1) Project Identification Sign and one

(1) Safety Performance Sign.

b. The construction project sign panels will each be electronically printed as a single decal and mounted on single sided vinyl faced

White Board as described in Paragraph "MATERIALS" below.

c. The layout of all signs shall be in accordance with the standards specified in the USACE graphics and sign standards manuals referenced above. Relevant portions of the manuals will be provided to the Contractor upon request. Examples of generic signs are shown on Plates 01 58 00.00 03-1 and 01 58 00.00 03-2 included at the end of this specification section.

2.1.1 Project Identification Sign

One (1) project identification sign constructed in accordance with Plate 01 58 00.00 03-1 and EP 310-6a shall be provided by the Contractor.

2.1.2 Safety Performance Sign

a. One (1) safety performance sign constructed in accordance with Plate 01 58 00.00 03-2 and EP 310-6a shall be provided by the Contractor.

b. The safety performance record shall be updated daily.

2.1.3 Project Identification Label

FOR LINE 1, Project Name FOR LINE 2, Brief Project Description FOR LINE 3, ARRA Signage

2.1.4 American Recovery and Reinvestment Act (ARRA) Emblem (If Applicable)

All construction projects funded by the American Recovery and Reinvestment Act (ARRA) shall display signage that features the Primary Emblem throughout the construction phase. The signage shall be displayed in a prominent location on site. The Primary Emblem should not be displayed at a size less than 6 inches in diameter. Images of the emblem are attached at the end of this Section and can also be downloaded at the following website:

http://www.recovery.gov/?q=content/president-and-vice-president-unveil-new-recovery-emble

2.1.5 Materials

The following are requirements for all of the construction project signs.

a. The sign faces shall be electronically printed on white non-reflective vinyl decals four (4) mil thick.

b. The sign face decals shall be mounted on panels of 1/2" thick White Board with single-sided vinyl facing. The entire circumference of the sign panels will be sealed and protected with white vinyl trim cap.

c. A protective over-laminate film shall be applied over the sign face decals capable of minimizing the deteriorating effects of ultraviolet radiation and providing additional protection against weathering and application of graffiti.

d. 2"x4" struts will be installed between the 4"x4" support posts to reinforce the top and bottom edges of the sign panels.

e. Wood material for the posts shall be preservative treated, structural grade Douglas Fir or No. 1 Southern Pine, or better.

All other wood members shall be of well seasoned, kiln dried, clear http://www.recovery.gov/?q=content/president-and-vice-president-unveil-new-recovery-emble http://www.recovery.gov/?q=content/president-and-vice-president-unveil-new-recovery-emble redwood, bald cypress, red cedar, Douglas fir, spruce, tulip poplar, or white pine. The lumber materials shall be free of splits, wane, and loose knots or pitch pockets. All members of the sign shall be fastened with screws or bolts of type, size, number, and spacing to provide rigid construction and neat appearance. If the vertical supports system does not rigidly support the sign due to local soil conditions and/or wind loading additional bracing of the sign supports shall be provided. This additional bracing shall be composed of 2"X4" bracing bolted to the inside face of each 4"x4" support post and firmly anchored to the ground behind the sign. This additional bracing is not required to be treated lumber.

f. All bolts shall be 0.375" diameter and 4" long Allen head bolts, threaded to match T-nuts.

PART 3 EXECUTION

3.1 INSTALLATION

The Contractor shall affix the panels to the posts with the Allen head bolts prior to erection of the signs, including drilling counter-sunk

0.375 inch diameter holes in the posts to match the T-nut locations. The Contractor shall take all precautions necessary to protect the faces of the signs from damage during assembly and construction. The signs shall be installed upon commencement of the work under this contract. The location in which each sign is to be installed shall be cleared and leveled to facilitate the installation of, and provide easy visual contact with, the signs. Installation and positioning of the sign plate and posts shall be as indicated on Plates 01 58 00.00 03-1 and 01 58

00.00 03-2, found at the end of this section. Excavation and backfilling of the holes for posts and installation of the posts, braces, and stakes shall be such that signs are installed plumb and level.

3.2 MAINTENANCE

The Contractor shall maintain the signs in good condition and the sign site in a neat condition throughout the construction period.

3.3 QUALITY CONTROL

The Contractor shall establish and maintain a quality control system for all operations performed under this section to assure compliance with contract requirements. The Contractor shall maintain records of his quality control for all operations performed, including, but not limited to, the following:

a. Quality of materials and workmanship

b. Overall appearance of signs and site

c. Observance of safety regulations

3.3.1 Records

A copy of the record of inspections, as well as records of any corrective action taken, shall be furnished to Contracting Officer in accordance with SECTION 01 45 04.00 10 CONTRACTOR QUALITY CONTROL.

-- End of Section --

Design and Construction

Supervised by:

4’-0"

4"X4" POST

4"X4" POST

4.5"

2.25"

1" 2"21"

3"3"

2"

4.5"

6.25"

10.5"

3"

4’-0"

4’-0"

6’-0" of Engineers

7.75"

21"3"

6"

1"x6"x4’

Contractor:

Information

U.S. Army Corps

NOT TO SCALE

1.25"

1.875"

1.875"

1.875"

1.875"

42"(max.)19"(max.) 2"

4.5"

9.5"

6"

LINE 1

LINE 2

LINE 3}

GENERIC PROJECT IDENTIFICATION SIGN

Refer to

Section 01 58 00.00 03 for Project

Identification Label

PLATE 01 58 00.00 03-1

NOTE:

FOR SIDE VIEW, SEE PLATE 01 58 00.00 03-2

3"

DETROIT DISTRICT

(313) 226-6766 www.lre.usace.army.mil

The White House // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 1

American Recovery and Reinvestment Act General Guidelines for Emblem and Logo Applications Version 1.0 03 / 20 / 09

Projects funded by the American Recovery and Reinvestment Act (ARRA) will bear a newly-designed emblem. The emblem is a symbol of President Obama’s commitment to the American People to invest their tax dollars wisely to put Americans back to work.

The purpose of this document is to provide general guidelines and specifications for using the ARRA emblem and corresponding logomark.

The White House // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 2

Variations and Usage There are two approved “marks” associated with the ARRA. To preserve the integrity of the ARRA emblem and logomark, make sure to apply them correctly. Altering, distorting or recreating the “marks” in any way weaken the power of the image and what it represents.

Layout and design of signs and communication materials will vary, so care must be taken when applying the emblem or logomark.

All projects which are funded by the ARRA should display signage that features the Primary Emblem throughout the construction phase. The signage should be displayed in a prominent location on site. Some exclusions may apply. The Primary Emblem can also be displayed on signs at events or conferences associated with the ARRA or the individual projects funded by the ARRA.

The Primary Emblem should not be displayed at a size less than 6 inches in diameter.

Primary Emblem

Horizontal Logomark

An alternate variation of the emblem exists for use in press releases and other online or offline communications. It should be used to brand the communications piece, but not in reference to the Primary Emblem usage.

The White House // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 3

Color All colors in the ARRA logos have precise color references, shown in the color specifications chart below. Always use the exact color values listed. Do not use screens or tints of any of the colors for any part of the logo. The CMYK values should be used for print applications. The RGB and HEX# values should be used for on-screen applications.

COLOR CMYK RGB HEX#

Navy 00 / 00 / 00 / 00 0 / 51 / 102 003366

Red 30 / 100 / 100 / 50 102 / 0 / 0 660000

Green 65 / 25 / 100 / 7 103 / 144 / 62 67903E

Light Blue 67 / 37 / 6 / 00 89 / 141 / 192 598DC0

Clear Space The clear space is shown as the value “X” in this exhibit. The minimum clear space must always be at least “X” on all sides of the logo. Whenever possible, increase the amount of clear space.

X = 1/2 Circle Radius

X

X

X

X

Primary Emblem

Horizontal Logomark

X = Character Height

X

X

X

X

The White House // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 4

For information regarding this document, please email:

recoveryquestions@gsa.gov

Please refer to this document as:

General Guidelines for Emblem and Logo Applications, Version 1.0

Contact Information

END OF AMENDMENT

File details come from the government source that posted it. Updated .