Drawing C-122-A (REV) Amendment 0001.pdf

PDF 563 KB Posted

Attached to
Tionesta Dam Gate Operating Machinery Replacement Federal contract opportunity
Solicitation number
W911WN20B8002
Issued by
Department of the Army Corps of Engineers Engineering District Pittsburgh

About this file

This document provides details for a federal solicitation seeking replacement of gate operating machinery. The U.S. Army Corps of Engineers, Pittsburgh District is soliciting proposals to replace existing vertical lift gate machinery with new round wire rope machinery at Tionesta Dam in Pennsylvania under solicitation number W911WN20B8002. The work includes removing the current machinery and installing new 115-ton capacity machinery that weighs less than 20 tons, replacing associated grating and power receptacles, and repairing concrete. The base contract includes one new machine plus options to replace up to three additional machines. The performance period is 720 days from notice to proceed and cost is estimated between $1 million to $5 million. The procurement is a 100% small business set-aside for a firm fixed price contract. The NAICS code is 237990. The IFB will be issued on March 23, 2020 via beta.sam.gov and proposals are due by the specified date.

View the file

Other files for this federal contract opportunity

Show all 16

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WELL NO. 1

EMERGENCY GATE

WELL NO. 2

EMERGENCY GATE

WELL NO. 3

EMERGENCY GATE

DRAIN (TYP)

ACCESS WELL

WELL NO. 2

SERVICE GATE

WELL NO. 3

SERVICE GATE

SERVICE BRIDGE

SLUICE GATE

OPENING

HOIST

GATE

OPENING

HOIST

GATE

WELL

ACCESS

WELL

ACCESS

OPENING

HOIST

GATE

OPENING

HOIST

GATE

TOWER

INTAKE

WELL NO. 1

SERVICE GATE

PIPING WELL

LOW DISCHARGE

PIPING WELL

LOW DISCHARGE

INTAKE TOWER

BOILER ROOM

D O

W N

LC

U P

F L

O W

C R

E E

K L

A K

E

T

IO

N E

S T

A

X

EL 1195.0

OPERATING FLOOR

A

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

D E

S

IG

N E

D B

Y

D R

A W

N B

Y

C H

E C

K E

D B

Y

S U

B M

IT

T E

D B

Y

S

IZ

E

IS

S

U E D

A T

E

S O

L

IC

IT

A T

IO

N N

O

C O

N T

R A

C T N

O

M A

R K

D E

S C

R

IP

T

IO

N D

A T

E

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R S

®of Engineers

US Army Corps

-M

A Y -2

:3

P

IT

T S

B U

R G

H D

IS

T R

IC

T

A N

S I

D

L

IB

E R

T Y A

V E

N U

E

P

IT

T S

B U

R G

H P

A

W

W N

B

P L

O T D

A T

E

A L L E

G H

E N

Y R

IV

E R B

A S

IN

R E

P L

A C

E G

A T

E O

P E

R A

T

IN

G M

A C

H

IN

E R

Y

T

IO

N E

S T

A C

R E

E K L

A K

E

CERTIFIED FINAL DOCUMENTS

A

B S

A K

M A

R

J

R U

S N

A K

KEY ELEVATION

3 3 22

1 1

44 5511

B

C R

A T

T Y

G A

T E O

P E

R A

T

IN

G M

A C

H

IN

E R

Y W

O R

K P

L A

T F

O R

M

L

U M

IN

U M P

L A

N K

IN

G P

L A

N

A1

WORK PLATFORM ALUMINUM PLANKING PLAN

0 4' 8'2'

NORTH

PLAN

SCALE: 1/4"=1'

1 1

T R

U E N

NOTES

SHEET KEYNOTES

OPTION NO. 1.

REPLACE PLANKING PANELS WITH GATE HOIST OPENING AS PART OF

OPTION NO. 2.

REPLACE PLANKING PANELS WITH GATE HOIST OPENING AS PART OF

OPTION NO. 3.

REPLACE PLANKING PANELS WITH GATE HOIST OPENING AS PART OF

BASE CONTRACT.

REPLACE PLANKING PANELS WITH GATE HOIST OPENING AS PART OF

CONTRACT. SEE NOTE 2, SHEET C-523 FOR ADDITIONAL INFORMATION.

WITH PLANKING PANELS WITHOUT OPENING AS PART OF BASE

EXISTING PLANKING PANELS (WITH HOIST OPENING) TO BE REPLACED

DRAWINGS O38e-U1-4/9 AND O38e-U1-4/10.

FOR EXISTING WORK PLATFORM PLANKING PLAN, REFER TO REFERENCE5.

OF THIS SHEET.

TOWER, SEE THE INTAKE TOWER KEY ELEVATION AT THE BOTTOM RIGHT

FOR GENERAL LOCATION OF THE WORK PLATFORM WITHIN THE INTAKE4.

WORK PLATFORM ALUMINUM GRATING BY THE CONTRACTOR.

INSTALLATION), EQUIPMENT, ETC., SHALL BE STORED ON THE EXISTING

NO MATERIALS (INCLUDING NEW ALUMINUM PLANKING PANELS PRIOR TO3.

PANELS (TYPICAL FOR ALL BOLD PANELS).

REMOVE EXISTING PLANKING PANELS AND REPLACE WITH NEW PLANKING2.

ARRANGEMENT PLAN AND DETAILS, SEE SHEETS C-523 AND C-524.

ALUMINUM PLANKING PANELS. FOR GATE WELL PLANKING PANEL

PLANKING OVER EACH GATE WELL IS COMPRISED OF SIX (6) INDIVIDUAL1.

LEGEND

X

ASSOCIATED SHEET KEYNOTE

NEW SLOTTED ALUMINUM PLANKING PANEL WITH

INTAKE TOWER CONCRETE WALLS

EL 1173.0

WORK PLATFORM

/S

M A

T T

H E

W P

R O

T H

E R P .E

F

E B

C-122-A

-0

-2

R E

V

IS

E D P

E R A

M E

N D

M E

N T

A1

C-523

A

AO38e_C-122-A
References
PW_WORKDIR:d0110017
_LRP_TitleBlock_FY18.dgn
LHTCH, PW_WORKDIR:d0110015
AO38e_NewPlnkngPln_C-PL01.dgn
XKEL1-SCRN30, PW_WORKDIR:d0110015
AO38e-SCTOWE.dgn
LHTCH-SCRN20, PW_WORKDIR:d0110017
AO38e_C-122-A.dgn
XKEL4-SCRN30, PW_WORKDIR:d0110015
AO38E_Gate Machinery_MY-3.dgn

File details come from the government source that posted it. Updated .