This is a Questions and Answers document related to maintenance and testing requirements for Self-Contained Breathing Apparatus (SCBA) equipment at Letterkenny Army Depot Fire and Emergency Services. The document clarifies the specific quantities and equipment specifications that require service: 78 total cylinders (48 45-minute 5500psi, 16 75-minute 5500psi, and 14 15-minute 4500psi cylinders), 40 SCBA units (34 Scott Air packs, 4 ska packs, and 2 Rit packs), and two compressor systems.
The equipment details include 3M Scott X3 PRO SCBA packs that meet NFPA 2018 standards, a Scott Revolve Air compressor (Model AC0404362110, Serial #02W-2506) located in the firehouse, and a Scott Liberty Series Air Trailer (Model ABL18016, Serial #45T6F-1429). The document explicitly states that SCBA Functional Flow Testing is not included in the scope of work.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Questions & Answers
Q1. Could you please provide the quantities of cylinders, air packs, and compressors that will require maintenance and testing over the course of a year?
A1. 1. Cylinders - 48(ea) 45min 5500psi, 16(ea) 75min 5500psi, 14(ea) 15min 4500psi SCBA - 34 Scott Air packs, 4 ska packs, 2 Rit packs
Q2. For each item, can you share the model number and pressure rating for the air packs?
A2. Pressure rating included above. No specific model number identified – 3M™ Scott™ Cylinders. SCBA packs are X3 PRO Scott 3m NFPA 2018
Q3. If applicable, could you also provide the model and serial number of the compressor and fill station?
A3. Compressor in firehouse is a Scott Revolve Air, Model AC0404362110, Serial #02W-2506.
Air Trailer Scott Liberty Series Model ABL18016, Serial #45T6F-1429
Q4. In reading the Scope of Work, I did not see any SCBA Functional Flow Testing. Is that correct? No Air-PAKs to be Flow Tested?
A4. That is correct, SCBA Flow testing should not be included.