1 Technical Exhibit H 3/27/19

TECHNICAL EXHIBIT H - ROOF DESCRIPTIONS

113- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access.

The Contractor will require a ladder to access the roof.

333- This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

1937- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access.

The Contractor will require a ladder to access the roof.

4612- This facility has a flat roof with gravel and has no parapet walls. There are not any permanent anchor points on the roof. This building has roof access by ladder.

5764- This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof. The building has roof access from mezzanine area.

7081- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access.

The Contractor will require a ladder to access the roof.

9205- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

12005- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

12007- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

20114- Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof.

20137- Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof.

20139- Sloped shingled roof, no parapet walls. There are not any permanent anchor points on the roof. The Contractor will require a ladder to access the roof.

2 Technical Exhibit H 3/27/19

21020- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

23025- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

34002- This facility has a flat roof with gravel and has parapet walls that are 42 inches in height or greater. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

39041- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

41015- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

48303- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

49010- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

52024- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

52940- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

52943- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

56425- - This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

3 Technical Exhibit H 3/27/19

56447- - This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

56471- - This facility has a sloped shingled roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

56519- Flat roof with gravel, has parapet walls less than 42 inches tall. No permanent anchor points on roof. The Contractor will require a ladder to access the roof.

70004- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

70020- - This facility has a standing seam sloped metal roof with no parapet walls. There are not any permanent anchor points on the roof or pre-designed roof access. The Contractor will require a ladder to access the roof.

90145- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof or pre-designed roof access.

The Contractor will require a ladder to access the roof.

91226- This facility has a flat roof with gravel and has parapet walls that are less than 42 inches in height. There are not any permanent anchor points on the roof. The building has a roof access ladder inside mechanical room.

EXAMPLES OF APPROVED FALL PROTECTION METHODS:

Flat roofs- Warning lines system, Water filled neoprene counterweight fall arrest anchor system, weighted temporary anchor point, guardrail systems.

Standing seam sloped metal roofs- Standing seam roof clamps with self retracting lifeline, mobile fall protection cart.

Sloped shingled roofs- Mobile fall protection cart.