ATT_3_Requirements_Matrix_26JUN2019.xlsx
XLSX spreadsheet 33 KB Posted
- Attached to
- Battlefield Effects Simulator (BES-III)
- Solicitation number
- W900KK-19-R-0038
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amend_0002_BES-III.pdf | ||
| Amend_0002_Conformed_Copy_BES_III.pdf | ||
| ATT_4_Pricing_Workbook_Revised_22JULY2019.xlsx | XLSX spreadsheet | |
| ATT_7_RFP_QuestionsAndAnswers_Rev_22JUL2019.pdf | ||
| Amend_0001_BES-III_Conformed_Copy.pdf | ||
| Amend_0001_BES-III.pdf | ||
| ATT_6_CDRL_Form_1423_26JUN2019.doc | DOC document | |
| ATT_4_Pricing_Workbook_26JUN2019.xlsx | XLSX spreadsheet | |
| ATT_2_BES_III_Spec_v1.1_26JUN2019.pdf | ||
| Exhibits_ABC_26JUN2019.pdf | ||
| ATT_5_Range_Data_Information_26JUN2019.pdf | ||
| RFP_BESIII_28JUN2019.pdf | ||
| ATT_1_SOW_v1.1_28JUN2019.pdf |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DO2 SPEC
This document is intended to verify that all contractors are meeting the specificaiton requirements
| Delivery Order # | Paragraph | Section Name | Are all requirements in this section being met by the Proposed Technical Solution? (Y/N) | If partially, How will the requirement be met in the future? | If partially, When will full requirement be met? | Proposed Technical Solution is Priced (Y/N) | If No, What is being Priced? |
| BES III SPEC | 3 | Requirements | |||||
| BES III SPEC | 3.1 | BES Devices | |||||
| BES III SPEC | 1 | Three Independent device types | |||||
| BES III SPEC | 2 | 60 Shot Capability | |||||
| BES III SPEC | 3 | 36 Shot Capability | |||||
| BES III SPEC | 4 | 6 Shot Capability | |||||
| BES III SPEC | 5 | Operate with current Government M34/M35 pyrotechnic cartridges | |||||
| BES III SPEC | 6 | Upgradeable to IPv6 without physical H/W mods or additions to launcher or range control system | |||||
| BES III SPEC | 7 | Physically/electronically interface with the FASIT system ICD.FASIT.SYS and ICD.FASIT.RED | |||||
| BES III SPEC | 8 | Capable of updating system S/W and firmware via FASIT interface without physically opening system H/W | |||||
| BES III SPEC | 9 | Capable of updating system S/W and firmware via FASIT interface through range infrastructure | |||||
| BES III SPEC | 10 | Operate using 120 V power connection as identified in ICD.FASIT.SYS | |||||
| BES III SPEC | 11 | Operate using a secondary connection from a 12 VDC power source as identified in ICD.FASIT.SYST and a 12V battery | |||||
| BES III SPEC | 12 | Initiate Built in Test (BIT) when powered on | |||||
| BES III SPEC | 13 | System shall provide visual cues for power on BIT status | |||||
| BES III SPEC | 14 | When power is lost or turned off, BES shall resume the firing sequence at the same round firing position as it was prior to power loss as well as after safety time delay requirement | |||||
| BES III SPEC | 15 | System BIT shall provide "Go" or "No Go" fault detection capabilities to identify operational readiness and failures | |||||
| BES III SPEC | 16 | System shall report BIT status to FASIT system in accordance with FASIT ICDs | |||||
| BES III SPEC | 17 | System shall mount on moving, stationary and ground platforms | |||||
| BES III SPEC | 18 | When mounted system shall be oriented to fire cartridges vertically | |||||
| BES III SPEC | 19 | System shall use the moving systems existing, attached mounting brackets | |||||
| BES III SPEC | 20 | System shall provide a secondary support mechanism when the existing mounting bracket doesn't fully support the BES | |||||
| BES III SPEC | 21 | System shall provide a means to mount the system to the target pit walls. | |||||
| BES III SPEC | 22 | Mounting means shall be offset from target silhouette and not interfere with target system's normal operation (USACE Open Range Design Guide - CEHNC 1110-1-23) | |||||
| BES III SPEC | 23 | System shall provide a ground mounting stand, that provides a stable platform and raises the system 12 inches from the ground to avoid environmental conditions i.e. standing water | |||||
| BES III SPEC | 24 | System set up and take down shall be completed within 10 minutes without the use of any special tools | |||||
| BES III SPEC | 25 | System shall provide a power connector in accordance with FASIT system ICD (ICD.FASIT.SYS) | |||||
| BES III SPEC | 26 | System shall use 13kV to 20kV negative peak voltage output signal for a duration of 900 +- 10 ms at a frequency of 1600 Hz to activate the M34 AND m35 CARTRIDGES | |||||
| BES III SPEC | 27 | System shall group pyrotechnic device chambers into firing zones | |||||
| BES III SPEC | 28 | System shall have a maximum of 6 firing zones | |||||
| BES III SPEC | 29 | Six Shot system shall not have a firing zone rqmt | |||||
| BES III SPEC | 30 | Table 2 has an example of the zone configuration rqmt | |||||
| BES III SPEC | 31 | System shall have capability to fire two pyrotechnic cartridges at the same time within the same firing zone. | |||||
| BES III SPEC | 32 | System shall fire in sequential order | |||||
| BES III SPEC | 33 | System shall resume firing from the next position in the designated sequence when there is a break in the firing sequence. | |||||
| BES III SPEC | 34 | System firing sequence shall no longer increment or process firing commands for a zone after all chambers have been fired within the specified firing zone. | |||||
| BES III SPEC | 35 | System shall allow the operator to reset the firing zone sequence of any firing zone to its initial position. | |||||
| BES III SPEC | 36 | System shall have a fail-safe shutoff device. | |||||
| BES III SPEC | 37 | System fail-safe shutoff device shall be clearly labeled "Safe" for when power is disconnected from the device and "armed" when power is connected to the device. | |||||
| BES III SPEC | 38 | System fail-safe device shall preclude inadvertent launcher activation during loading and unloading operations. | |||||
| BES III SPEC | 39 | System shall have two intentional human-in-the-loop procedures required to arm the launcher. | |||||
| BES III SPEC | 40 | All system safety labeling shall be in accordance with MIL-STD-1472. | |||||
| BES III SPEC | 41 | When the system assembly is opened to load and unload pyrotechnic cartridges the launcher will employ an electromechanical interlock that makes the system incapable of firing pyrotechnic cartridges. | |||||
| BES III SPEC | 42 | When System electromechanical interlock is closed it shall return the system to its operational state. | |||||
| BES III SPEC | 43 | System shall have status light(s) that indicate when the launcher is armed (red) and the unit is safe (green) | |||||
| BES III SPEC | 44 | System status light(s) shall be clearly visible to operator and maintenance personnel from a minimum distance of 15 ft. when personnel are directly facing the launcher without obstruction in direct sunlight and at night. | |||||
| BES III SPEC | 45 | System shall have a 60 second safety delay after the launcher is armed, before the launcher can fire pyrotechnic cartridges. System shall not process fire commands during the safety delay. | |||||
| BES III SPEC | 46 | The operator shall be able to load and unload launcher by hand without the use of tools. | |||||
| BES III SPEC | 47 | System load and unload procedures shall be completed in a maximum of 5 minutes. | |||||
| BES III SPEC | 48 | 60 Shot launcher assembly shall not exceed a two-person lift weight rqmt , as defined in MIL-STD-1472, in an unloaded configuration. | |||||
| BES III SPEC | 49 | 36 and 6 Shot launcher assembly shall not exceed a one-person lift weight rqmt , as defined in MIL-STD-1472, in an unloaded configuration. | |||||
| BES III SPEC | 50 | 60 shot launcher assembly shall not exceed the following dimensions: 34.5 inches (length) x 18.5 inches (width) x 12 inches (height). | |||||
| BES III SPEC | 51 | 36 shot launcher assembly shall not exceed the following dimensions: 26.5 inches (length) x 18.5 inches (width) x 12.5 inches (height). | |||||
| BES III SPEC | 52 | 6 shot launcher assembly shall not exceed the following dimensions: 20 inches (length) x 10 inches (width) x 10 inches (height). | |||||
| BES III SPEC | 53 | Launcher surfaces shall be painted with low visibility lusterless, non-reflective type FED-STD-595, color 33105(Field Drab, color 34082 (Dark Green) or color 33798 (Desert Sand). | |||||
| BES III SPEC | 54 | Non-standard colors (other than above) maybe used only where necessary for proper device operation; for safety (warning labels), component identification (ID labels and reference designators), electromagnetic transmission surfaces, or small mechanical fasteners (rivets, nuts, bolts, cable lanyards, cable tie downs). | |||||
| BES III SPEC | 55 | System exempted items shall not exhibit a highly reflective or polished surface and in no case shall the area of non-standard color exceed 1 square inch on the same reflective plane. | |||||
| BES III SPEC | 56 | System shall have a removable environmental cover to protect the launcher from debris and natural elements , such as rain and snow when not in use. | |||||
| BES III SPEC | 57 | System shall have a maximum Mean Time to Repair (MTTR) of 60 minutes with supplied documentation, tools and test equipment. | |||||
| BES III SPEC | 58 | System shall have a minimum Mean Time Between Failure (MTBF) of 1056 hrs (44 days). | |||||
| BES III SPEC | 59 | All exposed system components, including connectors, cables, systems and subsystems shall be capable of full functionality without degradation in performance when operated and/or stored in the identified environmental conditions and as tested in MIL-STD-810 | |||||
| BES III SPEC | 60 | System environmental exposure shall not cause binding, blistering or system deformation, cause degraded, partial, unsafe or failed operations. | |||||
| BES III SPEC | 61 | All system components shall be designed and configured to withstand the typical stresses and environments associated with handling, transportation and system reconfiguration | |||||
| BES III SPEC | 62 | The following are the minimum environmental test and procedures applicable for the system: | |||||
| BES III SPEC | 63 | High Temperature - Method 505.5 Solar Radiation (Sunshine), Procedure I (Cycling for Thermal effects), Method 501.5 High Temperature, Procedure I (Storage) and Procedure II (Operation). | |||||
| BES III SPEC | 64 | Low Temperature - Method 502.5 Low Temperature, Procedure I (Storage) and Procedure II (Operation). | |||||
| BES III SPEC | 65 | Humidity - Method 507.5 Humidity Procedure III (Aggravated Cycle). | |||||
| BES III SPEC | 66 | Salt/Fog - Method 509.5 Salt Fog. | |||||
| BES III SPEC | 67 | Sand and Dust - 510.5 Sand and Dust, Procedure I (Blowing Dust) and Procedure III (Blowing Sand). | |||||
| BES III SPEC | 68 | Rain - Method 506.5 Rain, Procedure I (Rain and blowing rain). | |||||
| BES III SPEC | 69 | Immersion - Method 512.5 Procedure I - Immersion | |||||
| BES III SPEC | 70 | Transportability - Loose transport (Cargo truck vibration profiles). | |||||
| BES III SPEC | 71 | System shall be safe to operate and maintain and shall not present safety, health or environmental hazards to operators and maintainers throughout the system life cycle | |||||
| BES III SPEC | 72 | System shall comply with 29 Code of Federal Regulation (CFR) 1910, National Fire Protection Association Codes. | |||||
| BES III SPEC | 73 | COTS equipment shall be certified as meeting the requirements of a nationally accredited safety-testing laboratory for its intended use (i.e. Underwriters Laboratories, Canadian Standards Association) or host nation equivalent. | |||||
| BES III SPEC | 74 | System electrical circuitry and installation shall comply with the requirements of the National Electric Code (ANSI/NFPA 70). | |||||
| BES III SPEC | 75 | Applicable system danger, caution and warning signs shall be designed and installed in accordance with ANSI Z535.3 and ANSI Z535.4 to warn user personnel of specific hazards such as voltage, current and thermal. | |||||
| BES III SPEC | 76 | System batteries shall be sufficiently separated from electronic components to prevent damage from corrosion. | |||||
| BES III SPEC | 77 | System shall not incorporate hazardous material, such as asbestos; glass fiber materials (as the outer surface or covering on cables, wire or other items where they may cause skin irritation to operating personnel); Halon or other Ozone-deleting substance; or Polyvinyl Chloride (PVC) materials. | |||||
| BES III SPEC | 78 | When system maintenance procedures require access to glass fibers, such as insulation, a caution note alerting maintenance personnel shall be visible. | |||||
| BES III SPEC | 79 | System shall preclude personnel or environment exposure to excessive levels of toxic, carcinogenic or otherwise hazardous materials as defined by the Occupational Health and Safety Administration (OSHA) and Environmental Protection Agency (EPA). | |||||
| BES III SPEC | 80 | System shall provide maximum safety to personnel and system equipment when installing, operating, adjusting and maintaining the equipment. | |||||
| BES III SPEC | 81 | The system shall provide fail-safe features for safety of personnel during installation, operation, maintenance, testing, support activities and disposal. | |||||
| BES III SPEC | 82 | System cables shall be minimized and located to preclude tripping hazards or cable damage. | |||||
| BES III SPEC | 83 | System equipment design shall provide maximum access and safety for user personnel while operating and maintaining the equipment | |||||
| BES III SPEC | 84 | Training equipment that can be mistaken for tactical equipment shall be marked "FOR TRAINING USE ONLY". | |||||
| BES III SPEC | 85 | System equipment and launcher housing shall be designed, installed and labeled so that it can be removed, handled and safely lifted. | |||||
| BES III SPEC | 86 | All system equipment labeling shall be in accordance with MIL-STD-1472 | |||||
| BES III SPEC | 87 | System moving parts shall have guards or provided with a safety system to prevent mechanical injury to operator and maintenance personnel. All edges and corners shall be rounded and free from burrs. | |||||
| BES III SPEC | 88 | If applicable to system design, battery enclosures shall prevent electrolyte from being expelled in the event of battery leakage or venting. | |||||
| BES III SPEC | 89 | System battery box venting will be provided to minimize gas build-up | |||||
| BES III SPEC | 90 | Explosive or harmful system battery gases shall not leak into the equipment or to another ignition source. | |||||
| BES III SPEC | 91 | System lithium battery enclosures shall be designed to preclude major system damage or serious personnel in the event of violent gas venting or battery cell ruptures causing high pressure with in the box. | |||||
| BES III SPEC | 92 | All system equipment shall be install and ground in accordance with applicable local and national electrical codes (i.e. NFPA 70 - National Electrical Code (NEC)) | |||||
| BES III SPEC | 93 | The pre-existence of GFE power, grounds or lightning protection at a range or facility shall not be a basis for non compliance to NEC. | |||||
| BES III SPEC | 94 | All down range BES launcher equipment and associated exposed cables shall be shielded and sealed to preclude damage by range wild life /vermin. | |||||
| BES III SPEC | 95 | All system equipment and enclosures shall be designed to prevent damage or intrusion from vermin found on a range such as deer, raccoons, beaver, rodents, snakes, insects, etc. | |||||
| BES III SPEC | 96 | All system hardware and subsystems shall be electromagnetically compatible. | |||||
| BES III SPEC | 97 | All system equipment shall operate in the electromagnetic environment described below without being a source of electromagnetic interference or a victim of site/location generated electromagnetic emissions, whether radiated or conducted. | |||||
| BES III SPEC | 98 | The electromagnetic environment expected at the utilization sites is a high electromagnetic noise environment for radiated energy. | |||||
| BES III SPEC | 99 | The system equipment site may be an active military training range with an active airfield operation. | |||||
| BES III SPEC | 100 | The system equipment site contains electromagnetic effects from licensed/authorized radio frequency emitters, lightning storms, power line transients, and electrostatic fields generated by human operators and maintainers; It is expected that considerable electromagnetic emissions from numerous radio both fixed and mobile and unintentional (i.e. ignition noise) will be adjacent to the system equipment. | |||||
| BES III SPEC | 101 | Mobile system elements shall not exceed electric field values specified in MIL-STD-464 Table 1D for operation on or non-interference with automotive systems | |||||
| BES III SPEC | 102 | All system components shall not be a source of Electromagnetic Interference (EMI) or a victim of E3 in the intended operational environment in which it is installed or at its operational locations and shall be able to operate within the EME such that the operational performance requirements are met. | |||||
| BES III SPEC | 103 | All system components shall not electronically interfere with its defined Electromagnetic Environment (EME) such that the system's operational performance requirements can be met. | |||||
| BES III SPEC | 104 | The expected EME at the operational site is 50 V/m (RMS) in the frequency range of 10 KHz to 10 GHz. | |||||
| BES III SPEC | 105 | Inter-system Electromagnetic Compatability (EMC) covers compatibility with, but is not limited to, the operational site EME, adjacent equipment, and friendly emitters (CB, UHF, VHF, cellular, etc.). | |||||
| BES III SPEC | 106 | Commercial system equipment shall be installed with adequate shielding, bonding, grounding and filtering to ensure electromagnetic compatibility with surrounding electrical and electronic equipment. | |||||
| BES III SPEC | 107 | System design shall protect personnel, fuels and ordinance from hazardous effects of electromagnetic radiation. | |||||
| BES III SPEC | 108 | Antennas and other devices that carry sufficient RF voltage to burn or injure personnel shall be protected from accidental contact in the same manner as AC voltages. | |||||
| BES III SPEC | 109 | Microwave or RF radiation signs shall be permanently affixed to warn personnel of danger zones. | |||||
| BES III SPEC | 110 | System transmitters shall comply with the maximum permissible exposure (MPE) limits for General Public/Uncontrolled Environments as contained in IEEE C95.1-2005. | |||||
| BES III SPEC | 111 | Microwave and antenna in controlled locations will need to be addressed separately with regard to MPE limits. | |||||
| BES III SPEC | 112 | The BES III shall pass the following tests from MIL-STD-461, Conducted Emissions (CE) 102, Conducted Susceptibility (CS) 101, CS 116, Radiated Emissions (RE) 102 and Radiated Susceptibility (RS) 103. | |||||
| BES III SPEC | 113 | The BES III shall be designed to be protected to survive or be able to endure lightning and Electromagnetic/Electrostatic Discharge. |
File details come from the government source that posted it.