The file's text, extracted by GovTribe without its formatting.
BASE YEAR
BASE YEAR ROOFING CONTRACT
0000 BASE YEAR - SUBCLINS 0001-0037
| SF/IN=Square Foot Per Inch Of Thickness |
| VLF = Vertical Linear Feet |
ITEM NO. SUPPLIES/SERVICES UNIT QUANTITY UNIT PRICE TOTAL
0001 ASBESTOS ROOFING
| 0001AA | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 5,000 |
| ASBESTOS SHINGLE ROOFING AND FELTS | | |
| (ONE LAYER OF SHINGLES) | | |
| 0001AB | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 4,000 |
| ASBESTOS ROLL ROOFING | | |
| 0001AC | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 8,000 |
| ASBESTOS CONTAINING BASE FLASHING/CURB | | |
| FLASHING | | |
| 0001AD | REMOVE AND DISPOSE OF FRIABLE OR | SF | 25,000 |
| NON-FRIABLE ASBESTOS CORRUGATED | | |
| FIBER REINFORCED CEMENT ROOF PANELS | | |
| 0001AE | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 2,000 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | |
| STATE REGULATIONS >0' UP TO 10' | | |
| 0001AF | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 2,000 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | |
| STATE REGULATIONS >10' UP TO 20' | | |
0002 ASPHALT ROOFING
| 0002AA | REMOVE AND DISPOSE OF ASPHALT | SF | 50,000 |
| SHINGLE ROOFING AND FELT UNDERLAYMENT | | |
| (ONE LAYER OF SHINGLES) | | |
0002AB REPLACE INDIVIDUAL ASPHALT SHINGLE EA 300
| 0002AC | RENAIL SHEATHING AND INSTALL | SF | 25,000 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | |
| AND 25 YEAR ASPHALT SHINGLES ON ALL | | |
| SLOPES | | |
| 0002AD | RENAIL SHEATHING AND INSTALL | SF | 50,000 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | |
| AND 40 YEAR ASPHALT SHINGLES ON ALL | | |
| SLOPES | | |
| 0002AE | INSTALL AN ADDITIONAL PLY OF THIRTY POUND | SF | 50,000 |
| ROOFING FELT, ALL SLOPES | | |
| 0002AF | INSTALL A SINGLE LAYER OF SYNTHETIC FIBER | SF | 20,000 |
| ROOFING FELT, ALL SLOPES | | |
| 0002AG | INSTALL AN ADDITIONAL LAYER OF SYNTHETIC | SF | 5,000 |
| FIBER ROOFING FELT, ALL SLOPES | | |
| 0002AH | REMOVE AND DISPOSE OF ASPHALT | SF | 2,500 |
| ROLL ROOFING AND UNDERLAYMENTS | | |
| 0002AI | RENAIL SHEATHING AND INSTALL DOUBLE | SF | 2,500 |
| COVERAGE ASPHALT ROLL ROOFING | | |
| AND UNDERLAYMENTS | | |
0003 BUILT UP AND IRMA ROOF SYSTEMS
| 0003AA | REMOVE AND DISPOSE OF LIGHT WEIGHT | SF/IN | 7,500 |
| GYPSUM MATERIAL | | |
| 0003AB | REMOVE AND DISPOSE OF BUILT UP | SF | 100,000 |
| ROOFING, ASPHALT | | |
| 0003AC | REMOVE AND DISPOSE OF BUILT UP | SF | 100,000 |
| ROOFING, COAL TAR | | |
| 0003AD | REMOVE AND SALVAGE GRAVEL BALLAST, APPLY | SF | 100,000 |
| FLOOD COAT OF HOT ASPHALT TO ROOF | | |
| SURFACE, COVER WITH SALVAGED GRAVEL | | |
| 0003AE | REMOVE AND DISPOSE OF GRAVEL BALLAST | SF | 100,000 |
| APPLY FLOOD COAT OF HOT ASPHALT TO ROOF | | |
| SURFACE, COVER WITH NEW GRAVEL | | |
| 0003AF | REMOVE GRAVEL, APPLY FLOOD COAT OF HOT | SF | 100,000 |
| ASPHALT AND NEW PLY OF ROOFING MEMBRANE | | |
| SET IN HOT ASPHALT, COVER WITH GRAVEL | | |
| BALLAST | | |
| 0003AG | REMOVE, SALVAGE AND REINSTALL ROCK | SF | 50,000 |
| BALLAST FROM ROOF SURFACE | | |
| 0003AH | REMOVE, SALVAGE AND REINSTALL EXISTING | SF | 50,000 |
| EPS BOARD INSULATION MATERIALS | | |
| 0003AI | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 50,000 |
| MEMBRANE AND PROTECTION MAT FROM | | |
| CONCRETE ROOF DECK | | |
| 0003AJ | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 50,000 |
| MEMBRANE, PROTECTION MAT AND GYPSUM | | |
| BOARD FROM STEEL ROOF DECK | | |
| 0003AK | INSTALL NEW RUBBERIZED ASPHALT ROOFING | SF | 50,000 |
| SYSTEM AND PROTECTION MAT USING | | |
| MATERIALS COMPATIBLE WITH EXISTING ROOF | | |
| SYSTEM | | |
| 0003AL | INSTALL NEW 1/2 INCH THICK CEMENT BOARD | SF | 50,000 |
| TO STEEL ROOFING DECK | | |
| 0003AM | INSTALL NEW COLD APPLIED SBS MEMBRANE | SF | 50,000 |
| PROTECTION COURSE OVER ROOF MEMBRANE | | |
| 0003AN | INSTALL NEW DRAINAGE MAT AND GEOTEXTILE | SF | 50,000 |
| FABRIC | | |
0004 MODIFIED BITUMEN
| 0004AA | REMOVE AND DISPOSE OF BUILT UP | SF | 250,000 |
| ROOFING, MODIFIED BITUMEN | | |
| 0004AB | INSTALL 150 MIL., SBS BASE AND SBS CAP | SF | 45,000 |
| FULLY ADHERED WITH TORCH WELDING | | |
| MODIFIED BITUMEN ROOFING SYSTEM, | | |
| FOR FIFTEEN YEAR WARRANTY, IN | | |
| ACCORDANCE WITH MFG'S RECOMMEND- | | |
| ATION | | |
| 0004AC | INSTALL FULLY ADHERED TORCH APPLIED | SF | 250,000 |
| APP 180 MIL BASE AND GRANULAR COATED | | |
| CAP SHEET WITH A FIFTEEN YEAR | | |
| WARRANTY, IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S RECOMMENDATION | | |
| 0004AD | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 25,000 |
| SBS 150 MOD. BIT. ROOFING SYSTEM | | |
| CONSISTING OF AN SBS 150 BASE AND CAP | | |
| SHEET IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S REQUIRMENTS | | |
| 0004AE | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 250,000 |
| APP180 MOD. BIT. ROOFING SYSTEM | | |
| CONSISTING OF AN APP 180 BASE AND CAP | | |
| SHEET IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S REQUIREMENTS | | |
0004AF INSTALL AN SBS 150 INTERPLY SHEET SF 26,000
0004AG INSTALL AN APP 180 INTERPLY SHEET SF 44,000
| 0004AH | INSTALL A WHITE BUTYL ELASTOMERIC | SF | 200,000 |
| ROOF COATING FORMULATED FOR USE ON MOD | | |
| BIT ROOFS SYSTEMS PER MANUFACTURERS | | |
| INSTALLATION AND TEN YEAR WARRANTY | | |
| REQUIREMENTS | | |
| 0004AJ | INSTALL ASPHALT BASE, FIBERED | SF | 125,000 |
| ALUMINUM COATING | | |
0004AK REPAIR MODIFIED BITUMEN SEAMS LF 5,000
0004AL PATCH MODIFIED BITUMEN ROOFING SF 5,000
| 0004AM | INSTALL MODIFIED BITUMEN BASE | SF | 30,000 |
| FLASHING | | |
| 0004AN | INSTALL MODIFIED BITUMEN CURB | SF | 30,000 |
| FLASHING | | |
0004AP INSTALL PITCH POCKET->0 UP TO 50 SQ IN EA 20
0004AQ INSTALL PITCH POCKET->50 UP TO 300 SQ IN EA 275
0005 METAL ROOFING AND WALL PANELS
0005AA REMOVE AND DISPOSE OF METAL ROOFING SF 25,000
0005AB INSTALL COPPER SHEET ROOFING SF 1,200
| 0005AC | INSTALL PLAIN PANEL METAL (STEEL) | SF | 200 |
| ROOFING | | |
| 0005AD | INSTALL PLAIN PANEL METAL (ALUMINUM) | SF | 200 |
| ROOFING | | |
| 0005AE | INSTALL FACTORY FINISHED PANEL | SF | 25,000 |
| METAL (STEEL) ROOFING STANDARD | | |
| COLORS | | |
| 0005AF | INSTALL FACTORY FINISHED PANEL | SF | 25,000 |
| METAL (ALUMINUM) ROOFING STANDARD | | |
| COLORS | | |
| 0005AG | INSTALL FACTORY FINSHED METAL WALL | SF | 25,000 |
| PANEL (STEEL) STANDARD MANUFACTURER | | |
| COLORS, NON-INSULATED PANEL | | |
| 0005AH | INSTALL FACTORY FINISHED METAL WALL | SF | 25,000 |
| PANEL (ALUMINUM) STANDARD MANUFACTURER | | |
| COLORS, NON-INSULATED PANEL | | |
| 0005AI | INSTALL NEW METAL HAT CHANNEL, 1.25 | LF | 850 |
| INCHES DEEP | | |
| 0005AJ | INSTALL NEW METAL HAT CHANNEL 1.5 | LF | 1,250 |
| INCHES DEEP | | |
| 0005AK | INSTALL NEW TRANSULCENT POLYCARBONATE | SF | 20,000 |
| HONEYCOMB STYLE WALL PANELS IN ALUMINUM | | |
| FRAME, 1.5 INCHES IN THICKNESS TO CLERESTORY | | |
| (EXTECH SERIES 3440 OR APPROVED EQUIVALENT | | |
0006 SLATE ROOFING
| 0006AA | REMOVE AND DISPOSE SLATE ROOFING | SF | 15,000 |
| AND FELT UNDERLAYMENT | | |
| 0006AB | REPLACE INDIVIDUAL BROKEN SLATE | EA | 50 |
| SHINGLES | | |
| 0006AC | REPLACE INDIVIDUAL BROKEN SLATE | EA | 10 |
| SHINGLES WITH GOVERNMENT SUPPLIED | | |
| SLATE SHINGLES | | |
| 0006AD | RENAIL SHEATHING, INSTALL 30 LB FELT, | SF | 2,000 |
| INSTALL MANUFACTURED SLATE (NON- | | |
| ASBESTOS FIBER CEMENT) SHINGLES | | |
| 0006AE | RENAIL SHEATHING AND INSTALL NATURAL | SF | 15,000 |
| SLATE ROOOFING AND 30 LB FELT | | |
| 0007 | CORRUGATED FIBER REINFORCED |
| CEMENT ROOF DECKING (NON-ASBESTOS) |
| 0007AA | REMOVE AND DISPOSE OF INSTALLED | SF | 2,500 |
| CORRUGATED FIBER REINFORCED | | |
| CEMENT ROOF DECKING > 2" thick | | |
0008 SINGLE PLY ROOFING EPDM ROOFING
0008AA REMOVE EPDM ROOFING SF 105,000
| 0008AB | REMOVE AND DISPOSE OF CONCRETE PAVER | SF | 1,400 |
| BALLAST FROM EPDM ROOF SYSTEMS | | |
| 0008AC | REMOVE AND DISPOSE OF RIVER ROCK BALLAST | SF | 1,400 |
| FROM LOOSE LAID, GRAVEL BALLASTED EPDM | | |
| ROOF SYSTEMS | | |
| 008AD | INSTALL FULLY ADHERED EPDM | SF | 1,400 |
| ROOFING SYSTEM, INCLUDING BASE AND | | |
| STRIP FLASHING,FASTENERS AND ADHESIVE | | |
| 0008AE | INSTALL EPDM ROOFING SYSTEM WITH | SF | 1,400 |
| CONCRETE ROOF PAVER BALLAST, BASE | | |
| STRIP AND PERFORATED EDGE FLASHING | | |
0008AF REPAIR EPDM SEAMS LF 150
0008AG PATCH EPDM ROOFING SF 40
0009 ROOF COATING SYSTEMS
| 0009AA | INSTALL FLUID APPLIED ELASTOMERIC | SF | 30,000 |
| ROOFING PRIMER, COVERED WITH THREE | | |
| (3) COATS ELASTOMERIC ACRYLIC ROOF | | |
| COATING ON EPDM ROOF SYSTEMS TO INCLUDE | | |
| COVERING SEAMS WITH REINFORCING FABRIC | | |
| 0009AB | INSTALL "SEAL-O-FLEX" ELASTOMERIC | SF | 32,000 |
| WATERPROOFING SYSTEM CONSISTING OF | | |
| THREE PART SYSTEM WITH CLOTH REINFORCING | | |
| 0009AC | INSTALL A THREE PART HYBRID URETHANE/ | SF | 50,000 |
| ELASTOMERIC ROOF COATING SYSTEM TO | | |
| INCLUDE FABRIC PLUS THREE COATS | | |
| 0009AD | INSTALL A POLYMETHYLMETHACRYLATE | SF | 50,000 |
| (PMMA) ROOF COATING SYSTEM OVER A | | |
| STRUCTURAL CONCRETE DECK CONSISTING OF | | |
| THREE PARTS TO INCLUDE FABRIC | | |
| 0009AE | INSTALL A POLYMETHYLMETHACRYLATE | SF | 50,000 |
| (PMMA) ROOF COATING SYSTEM OVER A LIGHT | | |
| WEIGHT CONCRETE DECK CONSISTING OF A ONE | | |
| INCH LAYER OF ROCK WOOL INSULATION WITH | | |
| SBS MODIFIED BITUMEN COVER BOARD SET IN | | |
| LOW RISE ADHESIVE FOLLOWED BY THE THREE | | |
| PART SYSTEM INCLUSIVE OF FABRIC | | |
| 0009AF | INSTALL PMMA FLASHING TO CURBS, ROOF | SF | 25,000 |
| PENETRATIONS AND PARAPET WALLS IAW | | |
| MANUFACTURER'S REQUIREMENTS | | |
0010 THERMOPOLYOLEFIN (TPO) ROOFING
0010AA REMOVE AND DISPOSE OF TPO ROOFING SYSTEM SF 15,000
| 0010AB | INSTALL A FULLY ADHERED, FLEECE BACKED | SF | 50,000 |
| POLYESTER SCRIM REINFORCED TPO MEMBRANE | | |
| WITH A NOMINAL THICKNESS OF 060 INCHES | | |
| (TPO THICKNESS) | | |
| 1010AC | INSTALL HOOK AND LOOP (VELCRO FASTENED) | SF | 50,000 |
| FLEECE BACKED 115 MIL TPO ROOF SYSTEM | | |
| (RapidLock Membrane and Insulation or approved | | |
| Equivalent) | | |
| 0010AC | INSTALL FULLY ADHERED FLEECE BACKED | SF | 12,000 |
| TPO FLASHING 0.060 INCH THICKNESS | | |
| 0010AD | INSTALL TPO VENT PIPE FLASHING, UP TO 3 | EA | 25 |
| INCHES IN DIAMETER | | |
| 0010AE | INSTALL TPO VENT PIPE FLASHING, FROM 3.1 | EA | 45 |
| INCHES IN DIAMTER AND LARGER | | |
0010AF REPAIR TPO/PVC MEMBRANE SEAMS LF 5,250
0010AG PATCH TPO/PVC ROOFING SF 7,500
| 0010AH | INSTALL FULLY ADHERED 12 INCH WIDE | LF | 1,500 |
| PERIMETER WARNING TAPE TEN FEET FROM | | |
| ROOF EDGE | | |
0011 ROOF WALKS
| 0011AA | INSTALL COMPOSITION TYPE TRAFFIC | SF | 1,000 |
| SURFACE (MINERAL SURFACE ASPHALT | | |
| PLANK) FOR BUILT UP ROOFS | | |
| 0011AB | INSTALL ADDITIONAL PLY OF TORCHED | SF | 2,200 |
| APPLIED MODIFIED BITUMEN CAP SHEET | | |
| WITH CONTRASTING GRANULAR COATING | | |
| TO MODIFIED BITUMEN ROOFING SYSTEM | | |
| 0011AC | INSTALL ADDITIONAL PLY OF COLD APPLIED | SF | 2,200 |
| MODIFIED BITUMEN CAP SHEET WITH | | |
| CONTRASTING GRANULAR COATING TO | | |
| MODIFIED BITUMEN ROOFING SYSTEM | | |
| 0011AD | INSTALL FULLY ADHERED, TPO COMPATIBLE | SF | 3,500 |
| FLEXIBLE WALK PATH WITH EMBOSSED | | |
| DIAMOND PLATE TREAD DESIGN OF A | | |
| CONTRASTING COLOR AND HIGH VISIBILITY | | |
| EDGES ON TPO ROOF SYSTEMS | | |
| 0012 | ROOF INSULATION / SHEETS, VENTING |
| NONVENTING BASE SHEETS |
0012AA REMOVE AND DISPOSE OF ROOF INSULATION SF/IN 500,000
| 0012AB | INSTALL FLAT STOCK RIGID INSULATION | SF/IN | 420,000 |
| BOARD, POLYISOCYANURATE FOAM | | |
| 0012AC | INSTALL TAPER STOCK INSULATION TO | SF/IN | 125,000 |
| SPECIFIED TAPER | | |
| 0012AD | INSTALL EXPANDED POLYSTYRENE BOARD (EPS) | SF/IN | 50,000 |
| INSULATION (Dow Blu-Board or equivalent) | | |
| 0012AE | INSTALL MODIFIED BITUMEN ASPHALT FACED | SF/IN | 25,000 |
| ROCK WOOL INSULATION BOARD (SMART BOARD) | | |
| 0012AF | INSTALL RIGID POLYISOCYANURATE COVER | SF | 25,000 |
| BOARD, 1/2 INCH THICKNESS (SecurShield HD RL | | |
| or an approved equivalent) with attached VELCRO | | |
| 0012AF | INSTALL FIBERGLASS FACED, HIGH DENSITY | SF | 25,000 |
| GYPSUM BOARD 1/2 INCH THICKNESS OVER | | |
| INSULATION AS A COVERBOARD (DENS-DECK | | |
| PRIME OR EQUIVALENT) | | |
| 0012AG | INSTALL VENTED BASE SHEET WITH | SF | 45,000 |
| GRID WAFFLE PATTERN | | |
| 0012AH | INSTALL NONVENTED BASE SHEET WITH | SF | 38,000 |
| GRID WAFFLE PATTERN | | |
| 0012AJ | INSTALL SNOW/ICE SHIELD (WINTER | SF | 25,000 |
| GUARD WATERPROOFING SHINGLE UNDER- | | |
| LAYMENT) ON ROOF EAVES, VALLEYS | | |
| AND SLOPE ROOF AREAS. | | |
0013 SHEET METAL
| 0013AA | REMOVE, DISPOSE AND REPLACE OR | SF | 6,000 |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH ALUMINUM | | |
| 0013AB | REMOVE, DISPOSE AND REPLACE OR | SF | 200 |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH COPPER | | |
| 0013AC | REMOVE, DISPOSE AND REPLACE OR | SF | 200 |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH STAINLESS STEEL | | |
| 0013AD | REMOVE, DISPOSE, AND REPLACE OR | SF | 6,000 |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| USING ALUMINUM SIDING | | |
| 0013AE | REMOVE, DISPOSE, AND REPLACE OR | SF | 750 |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| USING VINYL SIDING AS FLASHING | | |
| GRAVEL STOP, EIGHT (8) INCH HIGH | | |
| 0013AF | REMOVE, DISPOSE AND REPLACE OR | LF | 600 |
| INSTALL NEW 8" HIGH GRAVEL STOP | | |
| ALUMINUM | | |
| 0013AG | REMOVE, DISPOSE AND REPLACE OR | LF | 300 |
| INSTALL NEW 8" HIGH GRAVEL STOP | | |
| COPPER | | |
| 0013AH | REMOVE, DISPOSE AND REPLACE OR | LF | 4,250 |
| INSTALL NEW ALUMINUM DRIP EDGE | | |
0014 BASE FLASHING
| 0014AA | REMOVE, DISPOSE AND REPLACE OR | SF | 600 |
| INSTALL NEW BASE FLASHING ALUMINUM | | |
| 0014AB | REMOVE, DISPOSE AND REPLACE OR | SF | 60 |
| INSTALL NEW BASE FLASHING COPPER | | |
| 0014AC | REMOVE, DISPOSE AND REPLACE OR | SF | 600 |
| INSTALL NEW BASE FLASHING | | |
| STAINLESS STEEL | | |
| 0015 | REMOVAL, DISPOSAL AND REPLACEMENT |
| OF REGLETS |
| 0015AA | REMOVAL, DISPOSAL AND REPLACE OR | LF | 220 |
| INSTALL NEW METAL REGLETS ALUMINUM | | |
| 0015AB | REMOVAL, DISPOSAL AND REPLACE OR | LF | 150 |
| INSTALL NEW METAL REGLETS COPPER | | |
0016 COUNTER AND VALLEY FLASHING
| 0016AA | REMOVAL, DISPOSAL AND REPLACE OR | SF | 3,500 |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH ALUMINUM | | |
| 0016AB | REMOVAL, DISPOSAL AND REPLACE OR | SF | 200 |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH COPPER | | |
| 0016AC | REMOVAL, DISPOSAL AND REPLACE OR | SF | 150 |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH STAINLESS | | |
| STEEL | | |
0017 VENT PIPE FLASHING
| 0017AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 150 |
| INSTALL NEW VENT PIPE FLASHING | | |
| ALUMINUM WITH LEAD RING > 0"UP TO | | |
| 2" PIPE | | |
| 0017AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 50 |
| INSTALL NEW VENT PIPE FLASHING | | |
| ALUMINUM WITH LEAD RING >2" UP TO | | |
| 4" PIPE | | |
0018 COPPER WITH LEAD RING
| 0018AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 2 |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING UP TO 2" PIPE | | |
| 0018AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 5 |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING >2" UP TO 3" PIPE | | |
| 0018AC | REMOVAL, DISPOSE AND REPLACE OR | EA | 30 |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING >3" UP TO 4" PIPE | | |
0019 GUTTERS AND SCUPPER LINING
| 0019AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 3,500 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| ALUMINUM | | |
| 0019AB | REMOVAL, DISPOSE AND REPLACE OR | LF | 250 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| COPPER | | |
| 0019AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 200 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| STAINLESS STEEL | | |
| 0019AD | REMOVAL, DISPOSE AND REPLACE OR | LF | 1,200 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| ALUMINUM | | |
| 0019AE | REMOVAL, DISPOSE AND REPLACE OR | LF | 500 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| COPPER | | |
| 0019AF | REMOVAL, DISPOSE AND REPLACE OR | LF | 15 |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| STAINLESS STEEL | | |
| 0019AG | REMOVAL, DISPOSE AND REPLACE OR | SF | 80 |
| INSTALL NEW BUILT IN GUTTER AND | | |
| SCUPPER LINING ALUMINUM | | |
| 0019AH | REMOVAL, DISPOSE AND REPLACE OR | SF | 50 |
| INSTALL NEW BUILT IN GUTTER AND | | |
| SCUPPER LINING COPPER | | |
| 0019AI | REMOVE DISPOSE AND REPLACE OR | LF | 250 |
| INSTALL NEW 6 INCH BOX STYLE GUTTERS | | |
| ALUMINUM | | |
0020 DOWNSPOUTS AND LEADERS
| 0020AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 2,100 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 3"x4" RECTANGULAR ALUMINUM | | |
| 0020AB | REMOVAL, DISPOSE AND REPLACE OR | LF | 220 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 3"x4" RECTANGULAR COPPER | | |
| 0020AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 1,600 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 5" X 4" RECTANGULAR ALUMINUM | | |
| 0020AD | REMOVAL, DISPOSE AND REPLACE OR | LF | 600 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 5" X 4" RECTANGULAR STAINLESS STEEL | | |
| 0020AE | REMOVAL, DISPOSE AND REPLACE OR | LF | 100 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 4" ROUND TYPE ALUMINUM | | |
| 0020AF | REMOVAL, DISPOSE AND REPLACE OR | LF | 50 |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 4" ROUND TYPE COPPER | | |
0021 ROOF DRAINS AND CONDUCTOR HEADS
| 0021AA | REMOVAL, DISPOSE AND REPLACE OR | EA | 5 |
| INSTALL NEW ROOF DRAINS AND | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | |
| >0" UP TO 3" PIPE | | |
| 0021AB | REMOVAL, DISPOSE AND REPLACE OR | EA | 30 |
| INSTALL NEW ROOF DRAINS AND | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | |
| >3" UP TO 5" PIPE | | |
| 0021AC | REMOVE, DISPOSE AND INSTALL NEW | SF | 250 |
| SHEET LEAD ON DRAIN BOWLS BEING | | |
| REPLACED UNDER CLINS AA OR AB ABOVE | | |
| 0021AD | REMOVE, DISPOSE AND INSTALL NEW | LF | 50 |
| DRAIN PIPING INTERNAL TO BUILDING, 4" TO | | |
| 6" PIPING | | |
0022 CONDUCTOR HEADS
| 0022AA | REMOVAL, DISPOSE AND REPLACE OR | SF | 4 |
| INSTALL NEW CONDUCTOR HEAD | | |
| ALUMINUM | | |
| 0022AB | REMOVAL, DISPOSE AND REPLACE OR | SF | 20 |
| INSTALL NEW CONDUCTOR HEAD | | |
| COPPER | | |
| 0023 | CLEANING DOWNSPOUTS, GUTTERS, ROOF |
| DRAINS AND CONDUCTOR HEADS |
| 0023AA | DOWNSPOUTS AND LEADER CLEANING | LF | 9,800 |
| ALL SIZES | | |
| 0023AB | GUTTER AND SCUPPER CLEANING (BUILT | LF | 17,850 |
| IN, K AND HALF ROUND) ALL SIZES | | |
| 0023AC | ROOF DRAIN CLEANING- INTERIOR TO | EA | 32 |
| BUILDING | | |
0024 MISCELLANEOUS METAL/VINYL WORK
| 0024AA | REMOVAL, DISPOSE AND REPLACE OR | LF | 50 |
| INSTALL NEW COPPER RIDGE ROLL | | |
| CAPPING | | |
| 0024AB | REMOVAL, DISPOSE AND REPLACE OR | SF | 525 |
| INSTALL NEW PREFINISHED ALUMINUM | | |
| COVERING ON RAKE AND OR FASCIA | | |
| BOARD | | |
| 0024AC | REMOVAL, DISPOSE AND REPLACE OR | LF | 300 |
| INSTALL NEW VENTED VINYL SOFFIT | | |
| 0024AD | REMOVE, DISPOSE AND REPLACE OR | LF | 300 |
| INSTALL NEW NON-VENTED VINYL SOFFIT | | |
0025 ROOF DECK REPAIR
| 0025AA | REMOVE AND DISPOSE LIGHT WEIGHT | SF/IN | 8,500 |
| CONCRETE OR GYPSUM ROOF DECK | | |
0025AB PRIME CONCRETE DECK WITH HOT ASPHALT SF 8,500
0025AC PRIME CONCRETE DECK WITH ASPHALT PRIMER SF 8,500
| 0025AD | PATCHING OF LIGHT WEIGHT CONCRETE | SF/IN | 4,000 |
| ROOF DECK | | |
| 0025AE | REMOVE AND DISPOSE ROOF DECKING | SF | 4,000 |
| (WOOD PLANKS) | | |
0025AF INSTALL ROOF DECKING (WOOD PLANKS) SF 4,000
| 0025AG | REMOVE AND DISPOSE PLYWOOD | SF | 600 |
| SHEATHING | | |
| 0025AH | INSTALL PLYWOOD SHEATHING 1/2" | SF | 55,000 |
| SCREWED IN PLACE | | |
| 0025AJ | INSTALL PLYWOOD SHEATHING 3/4" | SF | 3,500 |
| SCREWED IN PLACE | | |
| 0025AK | INSTALL PLYWOOD SHEATHING 1" | SF | 3,500 |
| SCREWED IN PLACE | | |
| 0025AL | REMOVE AND DISPOSE OF EXISITNG | SF | 1,000 |
| CORRUGATED METAL ROOF DECK | | |
| 0025AM | INSTALL NEW OPEN TYPE, GALVANIZED, | SF | 3,125 |
| 1-1/2 INCH DEEP WIDE RIB, 20 GAGE METAL | | |
| DECKING | | |
| 0025AN | PATCH CORRUGATED METAL DECKING | SF | 900 |
| WITH 20 GAGE GALVANIZED METAL | | |
| DECKING, 1-1/2 INCH DEEP WIDE RIB PANEL | | |
0026 MISCELLANEOUS WOOD
| 0026AA | REMOVE, DISPOSE AND REPLACE WOOD | BF | 2,500 |
| RAFTERS AND LOOKOUTS | | |
| 0026AB | REMOVE, DISPOSE AND REPLACE WOOD | LF | 500 |
| CANTS | | |
| 0026AC | REMOVE, DISPOSE AND REPLACE FIBER | LF | 4,000 |
| CANTS | | |
| 0026AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 4,000 |
| NEW ROCK WOOL/MINERAL WOOL CANT STRIP | | |
0026AE REMOVE, DISPOSE AND REPLACE NAILERS BF 15,000
| 0026AF | REMOVE, DISPOSE AND REPLACE WOOD | SF | 2,000 |
| SOFFIT | | |
| 0026AG | REMOVE, DISPOSE AND REPLACE CORNICE | LF | 125 |
| TRIM | | |
| 0026AH | REMOVE, DISPOSE AND REPLACE RAKE | BF | 4,500 |
| TRIM | | |
| 0026AJ | REMOVE, DISPOSE AND REPLACE FASCIA | BF | 5,000 |
| BOARD | | |
| 0026AK | REMOVE, DISPOSE AND REPLACE WOOD | BF | 500 |
| TRUSS MEMBERS | | |
| 0027 | CAULKING, BACKER ROD AND EXPANSION |
| JOINTS |
0027AA INSTALL CAULKING LF 5,000
0027AB INSTALL BACKER ROD LF 5,000
| 0027AC | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 3,000 |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | |
| EQUIVALENT) ALUMINUM | | |
| 0027AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 3,000 |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | |
| EQUIVALENT) STAINLESS STEEL | | |
| 0027AE | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | 3,000 |
| NEW CLOSED CELL RESILIENT FOAM TUBE INSIDE | | |
| ROOF EXPANSION JOINTS ( 1 INCH TO 4 | | |
| INCHES IN DIAMETER) | | |
0028 PAINTING
| 0028AA | PREPARE SURFACE, PRIME AND PAINT | SF | 250 |
| FERROUS SURFACES | | |
| 0028AB | PREPARE SURFACE, PRIME AND PAINT | SF | 120 |
| GALVANIZED SURFACES | | |
| 0028AC | PREPARE SURFACE, PRIME AND PAINT | SF | 600 |
| WOOD SURFACES | | |
| 0028AD | PREPARE SURFACE, PRIME AND PAINT | SF | 120 |
| ALUMINUM AND ALUMINUM ALLOY SURFACES | | |
0029 SPLASH BLOCKS
| 0029AA | INSTALL PRECAST CONCRETE SPLASH | EA | 100 |
| BLOCKS AT DOWNSPOUTS | | |
0030 ROOF INSPECTION AND TESTING
| 0030AA | THERMOGRAPHIC TESTING | SF | 80,000 |
| (INFRARED SCANNING)-INITIAL OR DIAGNOSTIC | | |
| INSEPCTION FOR WATER INFILTRATION | | |
| 0030AB | THERMOGRAPHIC TESTING (IR SCAN) EIGHT | SF | 50,000 |
| MONTH WARRANTY INSPECTION | | |
| 0030AC | INSULATION INSPECTION | EA | 25 |
| (CORE SAMPLES) | | |
| 0030AD | TEST FOR ASBESTOS CONTAINING | EA | 15 |
| ROOFING MATERIALS | | |
| 0030AE | TCLP TESTING FOR LEAD-48 HR | EA | 1 |
| TURNAROUND | | |
| 0030AF | TCLP TESTING FOR LEAD-96 HR | EA | 5 |
| TURNAROUND | | |
| 0030AG | TCLP TESTING FOR LEAD-120 HR | EA | 15 |
| TURNAROUND | | |
| 0030AH | CONDUCT LOW VOLTAGE ELECTRONIC LEAK | SF | 50,000 |
| DETECTION TESTING ON MEMBRANE ROOF | | |
| SYSTEMS | | |
0031 MISCELLANEOUS
0031AA DRYVIT CUT/PATCH SF 1,000
| 0031AB | CUT AND REPOINT MASONRY (BRICK | LF | 950 |
| AND BLOCK) | | |
0031AC CUT AND REPOINT MASONRY (STONE) LF 500
| 0031AD | CUT AND PATCH COATED FOAM ROOF TO 1" | SF | 1,250 |
| DEEP | | |
| 0031AE | INSTALL "RIDGE-IT" ANCHOR SYSTEM ON | EA | 250 |
| SLOPED ROOF SYSTEMS | | |
0032 TEMPORARY SCAFFOLDING
| 0032AA | CONSTRUCT FREE STANDING TEMPORARY | VLF | 100 |
| SCAFFOLDING STAIR TOWER TO PROVIDE SAFE | | |
| ACCESS TO ROOF (Vertical linear feet) | | |
| UP TO 25 VERTICAL LINEAR FEET | | |
| 0032AB | CONSTRUCT FREE STANDING TEMPORARY | VLF | 100 |
| SCAFFOLDING STAIR TOWER FOR ROOF | | |
| ACCESS 26 TO 35 VERTICAL LINEAR FEET | | |
| 0032AC | CONSTRUCT FREE STANDING TEMPORARY | VLF | 100 |
| SCAFFOLDING STAIR TOWER FOR ROOF | | |
| ACCESS 36 TO 45 VERTICAL LINEAR FEET | | |
| 0032AD | CONSTRUCT FREE STANDING TEMPORARY | VLF | 100 |
| SCAFFOLDING STAIR TOWER FOR ROOF ACCESS | | |
| ACCESS 46 VLF AND GREATER | | |
| 0032AE | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 100 |
| STAIR TOWER FOR ROOF ACCESS | | |
| UP TO 25 VERTICAL LINEAR FEET | | |
| 0032AF | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 100 |
| STAIR TOWER FOR ROOF ACCESS | | |
| 26 VLF TO 35 VLF | | |
| 0032AG | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 100 |
| STAIR TOWER FOR ROOF ACCESS | | |
| 36 VLF TO 45 VLF | | |
| 0032AH | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | 100 |
| STAIR TOWER FOR ROOF ACCESS | | |
| 46 VLF AND GREATER | | |
| 0032AI | CONSTRUCT FREE STANDING, TEMPORARY | CSF | 100 |
| SCAFFOLDING AROUND BUILDING PERIMETER | | |
| TO SUPPORT ROOF WORK. Price to include | | |
| walk boards, rails, toe boards and outriggers (as | | |
| required) | | |
| 0032AJ | CONSTRUCT FIXED (ATTACHED TO BUILDING ) | CSF | 100 |
| TEMPORARY SCAFFOLDING AROUND BUILDING | | |
| PERIMETER TO SUPPORT ROOF WORK. Price to | | |
| include walk boards, rails, toe boards and out riggers | | |
| (as required) | | |
0033 SNOW GUARDS & VENTILATORS
| 0033AA | COPPER SNOW GUARD, NO. 100 BB | EA | 100 |
| INSTALLED IN CONJUNCTION WITH | | |
| INSTALLATION OF NEW SLATE OR | | |
| MANUFACTURED SLATE 630 LBS. EA, | | |
| BRASS CLEAT .O80 THICK 1/2 HARD | | |
| COPPER CLEAT (SHOE) .050 THICK | | |
| 0033AB | INSTALL MECHANICALLY FASTENED, CLEAR | EA | 700 |
| POLYCARBONATE SNOW AND ICE GUARDS ON | | |
| SLOPED ROOF SYSTEMS (SNO-BLX™ , SNO-JAX™ | | |
| OR AN APPROVED EQUIVALENT) | | |
| 0033AC | INSTALL MECHANICALLY FASTENED ALUMINUM | EA | 300 |
| SNOW AND ICE GUARDS ON SLOPED ROOF | | |
| SYSTEMS | | |
| 0033AD | INSTALL MECHANICALLY FASTENED STAINLESS | EA | 300 |
| STEEL SNOW AND ICE GUARDS ON SLOPED ROOF | | |
| SYSTEMS | | |
| 0033AE | INSTALL DOUBLE RAIL SNOW FENCE WITH ICE | LF | 2,000 |
| CLIPS TO METAL ROOF SYSTEMS 3/12 PITCH OR | | |
| GREATER (S-5! CLIPS ANF TWO RAIL SNOW-FENCE | | |
| ™ WITH SNO-CLIPS ™ OR APPROVED EQUIVALENT) | | |
| 0033AF | INSTALL S-5! BRACKET (OR EQUIVALENT) WITH | EA | 2,000 |
| RAM-GUARD ™ SNOW RETENTION DEVICE (OR | | |
| EQUIVALENT) TO METAL ROOF SYSTEMS 3/12 | | |
| PITCH OR GREATER | | |
| 0033AG | REMOVAL, DISPOSE AND REPLACE OR | LF | 3,250 |
| INSTALL NEW ROOF RIDGE VENTILATOR | | |
| 0033AH | REMOVE AND DISPOSE OF METAL ROOF | CF | 1,000 |
| VENTILATORS. REMOVE VENTILATOR | | |
| AND ALL ASSOCIATED HARDWARE. TURN | | |
| ALL METAL INTO METAL SALVAGE | | |
| 0033AJ | DISCONNECT AND RECONNECT HVAC UNIT | EA | 50 |
| (1-3 TON) TO RAISE 18" MINIMUM TO | | |
| INCLUDE ALL PIPING, ELECTRICAL, | | |
| CURBING AND STEEL | | |
| 0033AK | PROVIDE GALVANIZED RAIN HOOD | SF | 100 |
| AROUND STACKS | | |
0033AL 8" TURBINE VENTILATOR EA 20
0033AM 14" TURBINE VENTILATOR EA 45
| 0033AN | REMOVE AND DISPOSE OF ABANDONED ROOF | CF | 500 |
| MOUNTED EQUIPMENT AND CURBS TO INCLUDE | | |
| ELECTRICAL ISOLATION AND DISCONNECT FROM | | |
| SOURCE PANEL AS APPLICABLE. | | |
0034 LIGHTENING PROTECTION SYSTEMS
| 0034AA | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 500 |
| PROTECTION SYSTEM (LPS) AIR TERMINAL | | |
| COPPER AND/OR ALUMINUM | | |
| 0034AB | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 750 |
| PROTECTION SYSTEM (LPS) MOUNTING BRACKET | | |
| COPPER AND/OR ALUMINUM | | |
| 0034AC | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | 1,250 |
| PROTECTION SYSTEM (LPS) COMPONENTS AND | | |
| CONDUCTORS, COPPER AND/OR ALUMINUM | | |
| 0034AD | PERFORM CONTINUITY AND ACCEPTANCE | EA | 5 |
| TESTING FOR LIGHTENING PROTECTION SYSTEM | | |
| AFTER REINSTALLATION | | |
0035 ROOF HATCHES AND LADDERS
| 0035AA | REMOVE, DISPOSE AND REPLACE OR INSTALL | EA | 5 |
| NEW LOCKABLE, INSULATED ALUMINUM ROOF | | |
| ACCESS HATCH, (BILCO TYPE "S", TYPE "E", | | |
| VERSA-MOUNT ™ OR EQUIVALENT), | | |
| 2.5 FT BY 3 FT OPENING | | |
| 0035AB | INSTALL NEW BILCO LADDER-UP ™ SAFETY POST | EA | 8 |
| ON NEW OR EXISTING ROOF ACCESS HATCH | | |
| LADDERS | | |
| 0035AC | INSTALL OSHA COMPLIANT GUARD RAIL | EA | 10 |
| SYSTEM TO NEW AND/OR EXISTING ROOF ACCESS | | |
| HATCHES (BILCO BIL-GUARD ™ OR EQUIVALENT) | | |
| 0035AD | INSTALL OSHA COMPLIANT FALL PROTECTION | LF | 100 |
| CAGE ON EXISTING VERTICAL ROOF ACCESS | | |
| LADDERS | | |
| 0035AE | INSTALL NEW FIXED, ROOF ACCESS LADDER | LF | 100 |
| ALUMINUM | | |
| 0035AF | INSTALL NEW FIXED, ROOF ACCESS LADDER | LF | 100 |
| STEEL | | |
| 0035AG | PROCURE AND INSTALL NEW STAIRS (INCLUSIVE | Riser | 100 |
| OF RISERS, TREADS AND SIDE RAILS FOR ACCESS | | |
| TO ROOF MOUNTED EQUIPMENT/PENTHOUSES | | |
| 3 FT WIDE, GRATED TREADS, 2 LINE PIPE RAIL | | |
0036 ROOF SAFETY RAIL SYSTEMS
| 0036AA | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, WALL | | |
| MOUNT, MASONRY WALL (BRICK), 42 INCH HGT | | |
| 0036AB | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, WALL | | |
| MOUNT, MASONRY WALL (CMU), 42 INCH HGT | | |
| 0036AC | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, WALL | | |
| MOUNT, CONCRETE WALL, 42 INCH HGT | | |
| 0036AD | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, PARAPET | | |
| MOUNT, BRICK PARAPET, 15-30 INCH POST HGT | | |
| 0036AE | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW,PARAPET | | |
| MOUNT, BRICK PARAPET, 31-42 INCH POST HGT | | |
| 0036AF | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, PARAPET | | |
| MOUNT, CMU PARAPET, 15-30 INCH POST HGT | | |
| 0036AG | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, PARAPET | | |
| MOUNT, CMU PARAPET, 31-42 INCH POST HGT | | |
| 0036AH | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, PARAPET | | |
| MOUNT, CONCRETE PARAPET, 15-30 INCH POST | | |
| HEIGHT | | |
| 0036AI | POST, PERMANENT RAIL SYSTEM, STEEL TUBE | EA | 50 |
| POWDER COATED SAFETY YELLOW, PARAPET | | |
| MOUNT, CONCRETE PARAPET, 31-42 INCH POST | | |
| HEIGHT | | |
| 0036AJ | BASE PLATE FOR NON-PENETRATING SAFETY | EA | 50 |
| RAIL SYSTEM | | |
| 0036AK | POST FOR BASE PLATES, STEEL POWDER COATED | EA | 50 |
| SAFETY YELLOW, 42 INCH HGT | | |
| 0036AL | TOP AND MID RAILS, STEEL POWDER COATED | PR | 50 |
| SAFETY YELLOW, 10 FT FIXED LENGTH | | |
| 0036AM | TOP AND MID RAILS, STEEL POWDER COATED | PR | 50 |
| SAFETY YELLOW, 8 FT FIXED LENGTH | | |
| 0036AN | TOP AND MID RAILS, STEEL POWDER COATED | PR | 50 |
| SAFETY YELLOW, ADJUSTABLE LENGTH 70-43 | | |
| INCHES | | |
| 0036AO | TOP AND MID RAILS, STEEL POWDER COATED | PR | 50 |
| SAFETY YELLOW, ADJUSTABLE LENGTH 43-29 | | |
| INCHES | | |
| 0036AP | OUTSIDE CORNER RAILS, 20.5 INCH O.C., POWDER | EA | 25 |
| COATED STEEL, SAFETY YELLOW | | |
| 0036AQ | INSIDE CORNER RAILS, 12.5 INCH O.C, POWDER | EA | 25 |
| COATED STEEL, SAFETY YELLOW. | | |
| 0037 | PAYMENT AND PERFORMANCE BOND | LS | 1 |
| THIS COST IS FOR PERFORMANCE AND | | |
| PAYMENT BONDS ONLY - NO OVERHEAD | | |
| OR OTHER COSTS. THE PERFORMANCE | | |
| AND PAYMENT BOND COST IS A DIRECT | | |
| COST REIMBURSEABLE ITEM. THE | | |
| CONTRACTOR WILL BE PAID THE ACTUAL | | |
| BOND COSTS UPON RECEIPT OF PROOF | | |
| OF PAYMENT OF THE BOND COSTS | | |
BASE YEAR TOTAL
&P &F
OPTION YR 1
ROOFING CONTRACT OPTION YEAR ONE
| SF/IN=Square Foot Per Inch Of Thickness |
| VLF = Vertical Linear Feet |
1000 OPTION YEAR 1 - SUBCLINS 1001-1037
ITEM NO. SUPPLIES/SERVICES UNIT QUANTITY UNIT PRICE TOTAL
1001 ASBESTOS ROOFING
| 1001AA | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 5,000 |
| ASBESTOS SHINGLE ROOFING AND FELTS | | |
| (ONE LAYER OF SHINGLES) | | |
| 1001AB | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 4,000 |
| ASBESTOS ROLL ROOFING | | |
| 1001AC | REMOVE AND DISPOSE OF NON-FRIABLE | SF | 8,000 |
| ASBESTOS CONTAINING BASE FLASHING/CURB | | |
| FLASHING | | |
| 1001AD | REMOVE AND DISPOSE OF FRIABLE OR | SF | 25,000 |
| NON-FRIABLE ASBESTOS CORRUGATED | | |
| FIBER REINFORCED CEMENT ROOF PANELS | | |
| 1001AE | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 2,000 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | |
| STATE REGULATIONS >0' UP TO 10' | | |
| 1001AF | TRANSITE REMOVAL (WALLS, CEILINGS, | SF | 2,000 |
| SOFFITS) COMPLY WITH ALL FEDERAL AND | | |
| STATE REGULATIONS >10' UP TO 20' | | |
1002 ASPHALT ROOFING
| 1002AA | REMOVE AND DISPOSE OF ASPHALT | SF | 50,000 |
| SHINGLE ROOFING AND FELT UNDERLAYMENT | | |
| (ONE LAYER OF SHINGLES) | | |
1002AB REPLACE INDIVIDUAL ASPHALT SHINGLE EA 300
| 1002AC | RENAIL SHEATHING AND INSTALL | SF | 25,000 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | |
| AND 25 YEAR ASPHALT SHINGLES ON ALL | | |
| SLOPES | | |
| 1002AD | RENAIL SHEATHING AND INSTALL | SF | 50,000 |
| ASPHALT SHINGLE ROOFING, 30 LB FELT | | |
| AND 40 YEAR ASPHALT SHINGLES ON ALL | | |
| SLOPES | | |
| 1002AE | INSTALL AN ADDITIONAL PLY OF THIRTY POUND | SF | 50,000 |
| ROOFING FELT, ALL SLOPES | | |
| 1002AF | INSTALL A SINGLE LAYER OF SYNTHETIC FIBER | SF | 20,000 |
| ROOFING FELT, ALL SLOPES | | |
| 1002AG | INSTALL AN ADDITIONAL LAYER OF SYNTHETIC | SF | 5,000 |
| FIBER ROOFING FELT, ALL SLOPES | | |
| 1002AH | REMOVE AND DISPOSE OF ASPHALT | SF | 2,500 |
| ROLL ROOFING AND UNDERLAYMENTS | | |
| 1002AI | RENAIL SHEATHING AND INSTALL DOUBLE | SF | 2,500 |
| COVERAGE ASPHALT ROLL ROOFING | | |
| AND UNDERLAYMENTS | | |
1003 BUILT UP AND IRMA ROOF SYSTEMS
| 1003AA | REMOVE AND DISPOSE OF LIGHT WEIGHT | SF/IN | 7,500 |
| GYPSUM MATERIAL | | |
| 1003AB | REMOVE AND DISPOSE OF BUILT UP | SF | 100,000 |
| ROOFING, ASPHALT | | |
| 1003AC | REMOVE AND DISPOSE OF BUILT UP | SF | 100,000 |
| ROOFING, COAL TAR | | |
| 1003AD | REMOVE AND SALVAGE GRAVEL BALLAST, APPLY | SF | 100,000 |
| FLOOD COAT OF HOT ASPHALT TO ROOF | | |
| SURFACE, COVER WITH SALVAGED GRAVEL | | |
| 1003AE | REMOVE AND DISPOSE OF GRAVEL BALLAST | SF | 100,000 |
| APPLY FLOOD COAT OF HOT ASPHALT TO ROOF | | |
| SURFACE, COVER WITH NEW GRAVEL | | |
| 1003 | REMOVE GRAVEL, APPLY FLOOD COAT OF HOT | SF | 100,000 |
| ASPHALT AND NEW PLY OF ROOFING MEMBRANE | | |
| SET IN HOT ASPHALT, COVER WITH GRAVEL | | |
| BALLAST | | |
| 1003AG | REMOVE, SALVAGE AND REINSTALL ROCK | SF | 50,000 |
| BALLAST FROM ROOF SURFACE | | |
| 1003AH | REMOVE, SALVAGE AND REINSTALL EXISTING | SF | 50,000 |
| EPS BOARD INSULATION MATERIALS | | |
| 1003AI | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 50,000 |
| MEMBRANE AND PROTECTION MAT FROM | | |
| CONCRETE ROOF DECK | | |
| 1003AJ | REMOVE AND DISPOSE OF THE EXISTING ROOF | SF | 50,000 |
| MEMBRANE, PROTECTION MAT AND GYPSUM | | |
| BOARD FROM STEEL ROOF DECK | | |
| 1003AK | INSTALL NEW RUBBERIZED ASPHALT ROOFING | SF | 50,000 |
| SYSTEM AND PROTECTION MAT USING | | |
| MATERIALS COMPATIBLE WITH EXISTING ROOF | | |
| SYSTEM | | |
| 1003AL | INSTALL NEW 1/2 INCH THICK CEMENT BOARD | SF | 50,000 |
| TO STEEL ROOFING DECK | | |
| 1003AM | INSTALL NEW COLD APPLIED SBS MEMBRANE | SF | 50,000 |
| PROTECTION COURSE OVER ROOF MEMBRANE | | |
| 1003AN | INSTALL NEW DRAINAGE MAT AND GEOTEXTILE | SF | 50,000 |
| FABRIC | | |
1004 MODIFIED BITUMEN
| 1004AA | REMOVE AND DISPOSE OF BUILT UP | SF | 250,000 |
| ROOFING, MODIFIED BITUMEN | | |
| 1004AB | INSTALL 150 MIL., SBS BASE AND SBS CAP | SF | 45,000 |
| FULLY ADHERED WITH TORCH WELDING | | |
| MODIFIED BITUMEN ROOFING SYSTEM, | | |
| FOR FIFTEEN YEAR WARRANTY, IN | | |
| ACCORDANCE WITH MFG'S RECOMMEND- | | |
| ATION | | |
| 1004AC | INSTALL FULLY ADHERED TORCH APPLIED | SF | 250,000 |
| APP 180 MIL BASE AND GRANULAR COATED | | |
| CAP SHEET WITH A FIFTEEN YEAR | | |
| WARRANTY, IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S RECOMMENDATION | | |
| 1004AD | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 25,000 |
| SBS 150 MOD. BIT. ROOFING SYSTEM | | |
| CONSISTING OF AN SBS 150 BASE AND CAP | | |
| SHEET IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S REQUIRMENTS | | |
| 1004AE | INSTALL A FULLY ADHERED, COLD APPLIED | SF | 250,000 |
| APP180 MOD. BIT. ROOFING SYSTEM | | |
| CONSISTING OF AN APP 180 BASE AND CAP | | |
| SHEET IN ACCORDANCE WITH THE | | |
| MANUFACTURER'S REQUIREMENTS | | |
1004AF INSTALL AN SBS 150 INTERPLY SHEET SF 26,000
1004AG INSTALL AN APP 180 INTERPLY SHEET SF 44,000
| 1004AH | INSTALL WHITE BUTYL ELASTOMERIC | SF | 200,000 |
| ROOF COATING FORMULATED FOR USE ON MOD | | |
| BIT ROOF SYSTEMS PER MANUFACTURER'S | | |
| INSTALLATION AND TEN YEAR WARRANTY | | |
| REQUIREMENTS | | |
| 1004AJ | INSTALL ASPHALT BASE, FIBERED | SF | 125,000 |
| ALUMINUM COATING | | |
1004AK REPAIR MODIFIED BITUMEN SEAMS LF 5,000
1004AL PATCH MODIFIED BITUMEN ROOFING SF 5,000
| 1004AM | INSTALL MODIFIED BITUMEN BASE | SF | 30,000 |
| FLASHING | | |
| 1004AN | INSTALL MODIFIED BITUMEN CURB | SF | 30,000 |
| FLASHING | | |
1004AP INSTALL PITCH POCKET->0 UP TO 50 SQ IN EA 20
1004AQ INSTALL PITCH POCKET->50 UP TO 300 SQ IN EA 275
1005 METAL ROOFING AND WALL PANELS
1005AA REMOVE AND DISPOSE OF METAL ROOFING SF 25,000
1005AB INSTALL COPPER SHEET ROOFING SF 1,200
| 1005AC | INSTALL PLAIN PANEL METAL (STEEL) | SF | 200 |
| ROOFING | | |
| 1005AD | INSTALL PLAIN PANEL METAL (ALUMINUM) | SF | 200 |
| ROOFING | | |
| | | 25,000 |
| 1005AE | INSTALL FACTORY FINISHED PANEL | SF | |
| METAL (STEEL) ROOFING STANDARD | | |
| COLORS | | |
| | | 25,000 |
| 1005AF | INSTALL FACTORY FINISHED PANEL | SF | |
| METAL (ALUMINUM) ROOFING STANDARD | | |
| COLORS | | |
| | | 25,000 |
| 1005AG | INSTALL FACTORY FINSHED METAL WALL | SF | |
| PANEL (STEEL) STANDARD MANUFACTURER | | |
| COLORS, NON-INSULATED PANEL | | |
| | | 25,000 |
| 1005AH | INSTALL FACTORY FINISHED METAL WALL | SF | |
| PANEL (ALUMINUM) STANDARD MANUFACTURER | | |
| COLORS, NON-INSULATED PANEL | | |
| | | 850 |
| 1005AI | INSTALL NEW METAL HAT CHANNEL, 1.25 | LF | |
| INCHES DEEP | | |
| | | 1,250 |
| 1005AJ | INSTALL NEW METAL HAT CHANNEL 1.5 | LF | |
| INCHES DEEP | | |
| | | 20,000 |
| 1005AK | INSTALL NEW TRANSULCENT POLYCARBONATE | SF | |
| HONEYCOMB STYLE WALL PANELS IN ALUMINUM | | |
| FRAME, 1.5 INCHES IN THICKNESS TO CLERESTORY | | |
| (EXTECH SERIES 3440 OR APPROVED EQUIVALENT | | |
| 1006 | SLATE ROOFING | | |
| | | 15,000 |
| 1006AA | REMOVE AND DISPOSE SLATE ROOFING | SF | |
| AND FELT UNDERLAYMENT | | |
| | | 50 |
| 1006AB | REPLACE INDIVIDUAL BROKEN SLATE | EA | |
| SHINGLES | | |
| | | 10 |
| 1006AC | REPLACE INDIVIDUAL BROKEN SLATE | EA | |
| SHINGLES WITH GOVERNMENT SUPPLIED | | |
| SLATE SHINGLES | | |
| | | 2,000 |
| 1006AD | RENAIL SHEATHING, INSTALL 30 LB FELT, | SF | |
| INSTALL MANUFACTURED SLATE (NON- | | |
| ASBESTOS FIBER CEMENT) SHINGLES | | |
| | | 15,000 |
| 1006AE | RENAIL SHEATHING AND INSTALL NATURAL | SF | |
| SLATE ROOOFING AND 30 LB FELT | | |
| 1007 | CORRUGATED FIBER REINFORCED | | |
| CEMENT ROOF DECKING | | |
| | | 2,500 |
| 1007AA | REMOVE AND DISPOSE OF INSTALLED | SF | |
| CORRUGATED FIBER REINFORCED | | |
| CEMENT ROOF DECKING > 2" thick | | |
| 1008 | SINGLE PLY ROOFING EPDM ROOFING | | |
| | | 105,000 |
| 1008AA | REMOVE EPDM ROOFING | SF | |
| | | 1,400 |
| 1008AB | REMOVE AND DISPOSE OF CONCRETE PAVER | SF | |
| BALLAST FROM EPDM ROOF SYSTEMS | | |
| | | 1,400 |
| 1008AC | REMOVE AND DISPOSE OF RIVER ROCK BALLAST | SF | |
| FROM LOOSE LAID, GRAVEL BALLASTED EPDM | | |
| ROOF SYSTEMS | | |
| | | 1,400 |
| 1008AD | INSTALL FULLY ADHERED EPDM | SF | |
| ROOFING SYSTEM, INCLUDING BASE AND | | |
| STRIP FLASHING,FASTENERS AND ADHESIVE | | |
| | | 1,400 |
| 1008AE | INSTALL EPDM ROOFING SYSTEM WITH | SF | |
| CONCRETE ROOF PAVER BALLAST, BASE | | |
| STRIP AND PERFORATED EDGE FLASHING | | |
| | | 150 |
| 1008AF | REPAIR EPDM SEAMS | LF | |
| | | 40 |
| 1008AG | PATCH EPDM ROOFING | SF | |
| 1009 | ELASTOMERIC ROOFING | | |
| | | 30,000 |
| 1009AA | INSTALL FLUID APPLIED ELASTOMERIC | SF | |
| ROOFING PRIMER, COVERED WITH THREE | | |
| (3) COATS ELASTOMERIC AND PROTECTIVE | | |
| GRANULES, NO URETHANE FOAM | | |
| INSULATION | | |
| | | 32,000 |
| 1009AB | INSTALL "SEAL-O-FLEX" ELASTOMERIC | SF | |
| WATERPROOFING SYSTEM CONSISTING OF | | |
| THREE PART SYSTEM WITH CLOTH | | |
| | | 50,000 |
| 1009AC | INSTALL A THREE PART HYBRID URETHANE/ | SF | |
| ELASTOMERIC ROOF COATING SYSTEM TO | | |
| INCLUDE FABRIC PLUS THREE COATS | | |
| | | 50,000 |
| 1009AD | INSTALL A POLYMETHYLMETHACRYLATE | SF | |
| (PMMA) ROOF COATING SYSTEM OVER A | | |
| STRUCTURAL CONCRETE DECK CONSISTING OF | | |
| THREE PARTS TO INCLUDE FABRIC | | |
| | | 50,000 |
| 1009AE | INSTALL A POLYMETHYLMETHACRYLATE | SF | |
| (PMMA) ROOF COATING SYSTEM OVER A LIGHT | | |
| WEIGHT CONCRETE DECK CONSISTING OF A ONE | | |
| INCH LAYER OF ROCK WOOL INSULATION WITH | | |
| SBS MODIFIED BITUMEN COVER BOARD SET IN | | |
| LOW RISE ADHESIVE FOLLOWED BY THE THREE | | |
| PART SYSTEM INCLUSIVE OF FABRIC | | |
| | | 25,000 |
| 1009AF | INSTALL PMMA FLASHING TO CURBS, ROOF | SF | |
| PENETRATIONS AND PARAPET WALLS IAW | | |
| MANUFACTURER'S REQUIREMENTS | | |
| 1010 | THERMOPOLYOLEFIN (TPO) ROOFING | | |
| | | 15,000 |
| 1010AA | REMOVE AND DISPOSE OF TPO ROOFING SYSTEM | SF | |
| | | 50,000 |
| 1010AB | INSTALL A FULLY ADHERED, FLEECE BACKED | SF | |
| POLYESTER SCRIM REINFORCED TPO MEMBRANE | | |
| WITH A NOMINAL THICKNESS OF 060 INCHES | | |
| (TPO THICKNESS) | | |
| | | 50,000 |
| 1010AC | INSTALL HOOK AND LOOP (VELCRO FASTENED) | SF | |
| FLEECE BACKED 115 MIL TPO ROOF SYSTEM | | |
| (RapidLock Membrane and Insulation or approved | | |
| Equivalent) | | |
| | | 12,000 |
| 1010AD | INSTALL FULLY ADHERED FLEECE BACKED | SF | |
| TPO FLASHING 0.060 INCH THICKNESS | | |
| | | 25 |
| 1010AE | INSTALL TPO VENT PIPE FLASHING, UP TO 3 | EA | |
| INCHES IN DIAMETER | | |
| | | 45 |
| 1010AF | INSTALL TPO VENT PIPE FLASHING, FROM 3.1 | EA | |
| INCHES IN DIAMETER AND LARGER | | |
| | | 5,250 |
| 1010AG | REPAIR TPO/PVC MEMBRANE SEAMS | LF | |
| | | 7,500 |
| 1010AH | PATCH TPO/PVC ROOFING | SF | |
| | | 1,500 |
| 1010AJ | INSTALL FULLY ADHERED 12 INCH WIDE | LF | |
| PERIMETER WARNING TAPE TEN FEET FROM | | |
| ROOF EDGE | | |
| 1011 | ROOF WALKS | | |
| | | 1,000 |
| 1011AA | INSTALL COMPOSITION TYPE TRAFFIC | SF | |
| SURFACE (MINERAL SURFACE ASPHALT | | |
| PLANK) FOR BUILT UP ROOFS | | |
| | | 2,200 |
| 1011AB | INSTALL ADDITIONAL PLY OF TORCHED | SF | |
| APPLIED MODIFIED BITUMEN CAP SHEET | | |
| WITH CONTRASTING GRANULAR COATING | | |
| TO MODIFIED BITUMEN ROOFING SYSTEM | | |
| | | 2,200 |
| 1011AC | INSTALL ADDITIONAL PLY OF COLD APPLIED | SF | |
| MODIFIED BITUMEN CAP SHEET WITH | | |
| CONTRASTING GRANULAR COATING TO | | |
| MODIFIED BITUMEN ROOFING SYSTEM | | |
| | | 3,500 |
| 1011AD | INSTALL FULLY ADHERED, TPO COMPATIBLE | SF | |
| FLEXIBLE WALK PATH WITH EMBOSSED | | |
| DIAMOND PLATE TREAD DESIGN OF A | | |
| CONTRASTING COLOR AND HIGH VISIBILITY | | |
| EDGES ON TPO ROOF SYSTEMS | | |
| 1012 | ROOF INSULATION / SHEETS, VENTING | | |
| NONVENTING BASE SHEETS | | |
| | | 500,000 |
| 1012AA | REMOVE AND DISPOSE OF ROOF INSULATION | SF/IN | |
| | | 420,000 |
| 1012AB | INSTALL FLAT STOCK RIGID INSULATION | SF/IN | |
| BOARD, POLYISOCYANURATE FOAM | | |
| | | 125,000 |
| 1012AC | INSTALL TAPER STOCK INSULATION TO | SF/IN | |
| SPECIFED TAPER | | |
| | | 50,000 |
| 1012AD | INSTALL EXPANDED POLYSTYRENE BOARD (EPS) | SF/IN | |
| INSULATION (DOW Blu-Board or equivalent) | | |
| | | 25,000 |
| 1012AE | INSTALL MODIFIED BITUMEN ASPHALT FACED | SF/IN | |
| ROCK WOOL INSULATION BOARD (SMART BOARD) | | |
| | | 25,000 |
| 1012AF | INSTALL RIGID POLYISOCYANURATE COVER | SF | |
| BOARD, 1/2 INCH THICKNESS (SecurShield HD RL | | |
| or an approved equivalent) with attached VELCRO | | |
| | | 25,000 |
| 1012AG | INSTALL FIBERGLASS FACED, HIGH DENSITY | SF | |
| GYPSUM BOARD 1/2 INCH THICKNESS OVER | | |
| INSULATION AS A COVERBOARD (DENS-DECK | | |
| PRIME OR EQUIVALENT) | | |
| | | 45,000 |
| 1012AH | INSTALL VENTED BASE SHEET WITH | SF | |
| GRID WAFFLE PATTERN | | |
| | | 38,000 |
| 1012AI | INSTALL NONVENTED BASE SHEET WITH | SF | |
| GRID WAFFLE PATTERN | | |
| | | 25,000 |
| 1012AJ | INSTALL SNOW/ICE SHIELD (WINTER | SF | |
| GUARD WATERPROOFING SHINGLE UNDER- | | |
| LAYMENT) ON ROOF EAVES, VALLEYS | | |
| AND SLOPE ROOF AREAS. | | |
| 1013 | SHEET METAL | | |
| | | 6,000 |
| 1013AA | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH ALUMINUM | | |
| | | 200 |
| 1013AB | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH COPPER | | |
| | | 200 |
| 1013AC | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| WITH STAINLESS STEEL | | |
| | | 6,000 |
| 1013AD | REMOVE, DISPOSE, AND REPLACE OR | SF | |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT, OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| USING ALUMINUM SIDING | | |
| | | 750 |
| 1013AE | REMOVE, DISPOSE, AND REPLACE OR | SF | |
| INSTALL NEW FLASHING, FASCIA, | | |
| SOFFIT OR GRAVEL STOP ON MINOR | | |
| FLAT, PITCHED OR CURVED SURFACES | | |
| USING VINYL SIDING AS FLASHING | | |
| GRAVEL STOP, EIGHT (8) INCH HIGH | | |
| | | 600 |
| 1013AF | REMOVE, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW 8" HIGH GRAVEL STOP | | |
| ALUMINUM | | |
| | | 300 |
| 1013AG | REMOVE, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW 8" HIGH GRAVEL STOP | | |
| COPPER | | |
| | | 4,250 |
| 1013AH | REMOVE, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW ALUMINUM DRIP EDGE | | |
| 1014 | BASE FLASHING | | |
| | | 600 |
| 1014AA | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW BASE FLASHING ALUMINUM | | |
| | | 60 |
| 1014AB | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW BASE FLASHING COPPER | | |
| | | 600 |
| 1014AC | REMOVE, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW BASE FLASHING | | |
| STAINLESS STEEL | | |
| 1015 | REMOVAL, DISPOSAL AND REPLACEMENT | | |
| OF REGLETS | | |
| | | 220 |
| 1015AA | REMOVAL, DISPOSAL AND REPLACE OR | LF | |
| INSTALL NEW METAL REGLETS ALUMINUM | | |
| | | 150 |
| 1015AB | REMOVAL, DISPOSAL AND REPLACE OR | LF | |
| INSTALL NEW METAL REGLETS COPPER | | |
| 1016 | COUNTER AND VALLEY FLASHING | | |
| | | 3,500 |
| 1016AA | REMOVAL, DISPOSAL AND REPLACE OR | SF | |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH ALUMINUM | | |
| | | 200 |
| 1016AB | REMOVAL, DISPOSAL AND REPLACE OR | SF | |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH COPPER | | |
| | | 150 |
| 1016AC | REMOVAL, DISPOSAL AND REPLACE OR | SF | |
| INSTALL NEW STEPPED, CAP, COUNTER | | |
| OR VALLEY FLASHING WITH STAINLESS | | |
| STEEL | | |
| 1017 | VENT PIPE FLASHING | | |
| | | 150 |
| 1017AA | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW VENT PIPE FLASHING | | |
| ALUMINUM WITH LEAD RING > 0"UP TO | | |
| 2" PIPE | | |
| | | 50 |
| 1017AB | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW VENT PIPE FLASHING | | |
| ALUMINUM WITH LEAD RING >2" UP TO | | |
| 4" PIPE | | |
| 1018 | COPPER WITH LEAD RING | | |
| | | 2 |
| 1018AA | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING UP TO 2" PIPE | | |
| | | 5 |
| 1018AB | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING >2" UP TO 3" PIPE | | |
| | | 30 |
| 1018AC | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW VENT PIPE FLASHING | | |
| COPPER WITH LEAD RING >3" UP TO 4" PIPE | | |
| 1019 | GUTTERS AND SCUPPER LINING | | |
| | | 3,500 |
| 1019AA | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| ALUMINUM | | |
| | | 250 |
| 1019AB | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| COPPER | | |
| | | 200 |
| 1019AC | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 21" TO 25" GIRTH | | |
| STAINLESS STEEL | | |
| | | 1,200 |
| 1019AD | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| ALUMINUM | | |
| | | 500 |
| 1019AE | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| COPPER | | |
| | | 15 |
| 1019AF | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW "K" TYPE OR HALF ROUND | | |
| GUTTERS, 26" TO 30" GIRTH | | |
| STAINLESS STEEL | | |
| | | 80 |
| 1019AG | REMOVAL, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW BUILT IN GUTTER AND | | |
| SCUPPER LINING ALUMINUM | | |
| | | 50 |
| 1019AH | REMOVAL, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW BUILT IN GUTTER AND | | |
| SCUPPER LINING COPPER | | |
| | | 250 |
| 1019AI | REMOVE DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW 6 INCH BOX STYLE GUTTERS | | |
| ALUMINUM | | |
| 1020 | DOWNSPOUTS AND LEADERS | | |
| | | 2,100 |
| 1020AA | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 3"x4" RECTANGULAR ALUMINUM | | |
| | | 220 |
| 1020AB | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 3"x4" RECTANGULAR COPPER | | |
| | | 1,600 |
| 1020AC | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 5" X 4" RECTANGULAR ALUMINUM | | |
| | | 600 |
| 1020AD | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 5" X 4" RECTANGULAR STAINLESS | | |
| | | 100 |
| 1020AE | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 4" ROUND TYPE ALUMINUM | | |
| | | 50 |
| 1020AF | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW DOWNSPOUTS OR LEADERS; | | |
| 4" ROUND TYPE COPPER | | |
| 1021 | ROOF DRAINS AND CONDUCTOR HEADS | | |
| | | 5 |
| 1021AA | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW ROOF DRAINS AND | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | |
| >0" UP TO 3" PIPE | | |
| | | 30 |
| 1021AB | REMOVAL, DISPOSE AND REPLACE OR | EA | |
| INSTALL NEW ROOF DRAINS AND | | |
| CONDUCTOR HEAD, CAST IRON 10" TOP | | |
| >3" UP TO 5" PIPE | | |
| | | 250 |
| 1021AC | REMOVE, DISPOSE AN DINSTALL NEW SHEET | SF | |
| LEAD ON DRAIN BOWLS BEING REPLACCED | | |
| UNDER CLINS AA AND AB ABOVE | | |
| | | 50 |
| 1021AD | REMOVE DISPOSE AND INSTALL NEW | LF | |
| DRAIN PIPING INTERNAL TO BUILDING, 4 IN. TO | | |
| 6 INCH PIPING, | | |
| 1022 | CONDUCTOR HEADS | | |
| | | 4 |
| 1022AA | REMOVAL, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW CONDUCTOR HEAD | | |
| ALUMINUM | | |
| | | 20 |
| 1022AB | REMOVAL, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW CONDUCTOR HEAD | | |
| COPPER | | |
| 1023 | CLEANING DOWNSPOUTS, GUTTERS, ROOF | | |
| DRAINS AND CONDUCTOR HEADS | | |
| | | 9,800 |
| 1023AA | DOWNSPOUTS AND LEADER CLEANING | LF | |
| ALL SIZES | | |
| | | 17,850 |
| 1023AB | GUTTER AND SCUPPER CLEANING (BUILT | LF | |
| IN, K AND HALF ROUND) ALL SIZES | | |
| | | 32 |
| 1023AC | ROOF DRAIN CLEANING- INTERIOR TO | EA | |
| BUILDING | | |
| 1024 | MISCELLANEOUS METAL/VINYL WORK | | |
| | | 50 |
| 1024AA | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW COPPER RIDGE ROLL | | |
| CAPPING | | |
| | | 525 |
| 1024AB | REMOVAL, DISPOSE AND REPLACE OR | SF | |
| INSTALL NEW PREFINISHED ALUMINUM | | |
| COVERING ON RAKE AND OR FASCIA | | |
| BOARD | | |
| | | 300 |
| 1024AC | REMOVE, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW VENTED VINYL SOFFIT | | |
| | | 300 |
| 1024AD | REMOVE, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW NON-VENTED VINYL SOFFIT | | |
| 1025 | ROOF DECK REPAIR | | |
| | | 8,500 |
| 1025AA | REMOVE AND DISPOSE LIGHT WEIGHT | SF/IN | |
| CONCRETE OR GYPSUM ROOF DECK | | |
| | | 8,500 |
| 1025AB | PRIME CONCRETE DECK WITH HOT ASPHALT | SF | |
| | | 8,500 |
| 1025AC | PRIME CONCRETE DECK WITH ASPHALT PRIMER | SF | |
| | | 4,000 |
| 1025AD | PATCHING OF LIGHT WEIGHT CONCRETE | SF/IN | |
| ROOF DECK | | |
| | | 4,000 |
| 1025AE | REMOVE AND DISPOSE ROOF DECKING | SF | |
| (WOOD PLANKS) | | |
| | | 4,000 |
| 1025AF | INSTALL ROOF DECKING (WOOD PLANKS) | SF | |
| | | 600 |
| 1025AG | REMOVE AND DISPOSE PLYWOOD | SF | |
| SHEATHING | | |
| | | 55,000 |
| 1025AH | INSTALL PLYWOOD SHEATHING 1/2" | SF | |
| SCREWED IN PLACE | | |
| | | 3,500 |
| 1025AJ | INSTALL PLYWOOD SHEATHING 3/4" | SF | |
| SCREWED IN PLACE | | |
| | | 3,500 |
| 1025AK | INSTALL PLYWOOD SHEATHING 1" | SF | |
| SCREWED IN PLACE | | |
| | | 1,000 |
| 1025AL | REMOVE AND DISPOSE OF EXISITNG | SF | |
| CORRUGATED METAL ROOF DECK | | |
| | | 3,125 |
| 1025AM | INSTALL NEW OPEN TYPE, GALVANIZED, | SF | |
| 1 1/2 INCH DEEP WIDE RIB, 20 GAGE METAL | | |
| DECKING | | |
| | | 900 |
| 1025AN | PATCH CORRUGATED METAL DECKING | SF | |
| WITH 20 GAGE GALVANIZED METAL | | |
| DECKING, 1 1/2 INCH DEEP WIDE RIB PANEL | | |
| 1026 | MISCELLANEOUS WOOD | | |
| | | 2,500 |
| 1026AA | REMOVE, DISPOSE AND REPLACE WOOD | BF | |
| RAFTERS AND LOOKOUTS | | |
| | | 500 |
| 1026AB | REMOVE, DISPOSE AND REPLACE WOOD | LF | |
| CANTS | | |
| | | 4,000 |
| 1026AC | REMOVE, DISPOSE AND REPLACE FIBER | LF | |
| CANTS | | |
| | | 4,000 |
| 1026AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | |
| NEW ROCK WOOL/MINERAL WOOL CANT STRIP | | |
| | | 15,000 |
| 1026AE | REMOVE, DISPOSE AND REPLACE NAILERS | BF | |
| | | 2,000 |
| 1026AF | REMOVE, DISPOSE AND REPLACE WOOD | SF | |
| SOFFIT | | |
| | | 125 |
| 1026AG | REMOVE, DISPOSE AND REPLACE CORNICE | LF | |
| TRIM | | |
| | | 4,500 |
| 1026AH | REMOVE, DISPOSE AND REPLACE RAKE | BF | |
| TRIM | | |
| | | 5,000 |
| 1026AJ | REMOVE, DISPOSE AND REPLACE FASCIA | BF | |
| BOARD | | |
| | | 500 |
| 1026AK | REMOVE, DISPOSE AND REPLACE WOOD | BF | |
| TRUSS MEMBERS | | |
| 1027 | CAULKING, BACKER ROD AND EXPANSION | | |
| JOINTS | | |
| | | 5,000 |
| 1027AA | INSTALL CAULKING | LF | |
| | | 5,000 |
| 1027AB | INSTALL BACKER ROD | LF | |
| | | 3,000 |
| 1027AC | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | |
| EQUIVALENT) ALUMINUM | | |
| | | 3,000 |
| 1027AD | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | |
| NEW PRE-MANUFACTURED EXPANSION JOINT | | |
| COVERS (EXPANDA-FLASH OR APPROVED | | |
| EQUIVALENT) STAINLESS STEEL | | |
| | | 3,000 |
| 1027AE | REMOVE, DISPOSE, AND REPLACE OR INSTALL | LF | |
| NEW CLOSED CELL RESILIENT FOAM TUBE INSIDE | | |
| ROOF EXPANSION JOINTS ( 1 INCH TO 4 | | |
| INCHES IN DIAMETER) | | |
| 1028 | PAINTING | | |
| | | 250 |
| 1028AA | PREPARE SURFACE, PRIME AND PAINT | SF | |
| FERROUS SURFACES | | |
| | | 120 |
| 1028AB | PREPARE SURFACE, PRIME AND PAINT | SF | |
| GALVANIZED SURFACES | | |
| | | 600 |
| 1028AC | PREPARE SURFACE, PRIME AND PAINT | SF | |
| WOOD SURFACES | | |
| | | 120 |
| 1028AD | PREPARE SURFACE, PRIME AND PAINT | SF | |
| ALUMINUM AND ALUMINUM ALLOY SURFACES | | |
| 1029 | SPLASH BLOCKS | | |
| | | 100 |
| 1029AA | INSTALL PRECAST CONCRETE SPLASH | EA | |
| BLOCKS AT DOWNSPOUTS | | |
| 1030 | ROOF INSPECTION AND TESTING | | |
| | | 80,000 |
| 1030AA | THERMOGRAPHIC TESTING | SF | |
| (INFRARED SCANNING) - INITIAL OR DIAGNOSTIC | | |
| INSPECTION FOR WATER INFILTRATION | | |
| | | 50,000 |
| 1030AB | THERMOGRAPHIC TESTING (IR SCAN) EIGHT | SF | |
| WARRANTY INSPECTION | | |
| | | 25 |
| 1030AC | INSULATION INSPECTION | EA | |
| (CORE SAMPLES) | | |
| | | 15 |
| 1030AD | TEST FOR ASBESTOS CONTAINING | EA | |
| ROOFING MATERIALS | | |
| | | 1 |
| 1030AE | TCLP TESTING FOR LEAD-48 HR | EA | |
| TURNAROUND | | |
| | | 5 |
| 1030AF | TCLP TESTING FOR LEAD-96 HR | EA | |
| TURNAROUND | | |
| | | 15 |
| 1030AG | TCLP TESTING FOR LEAD-120 HR | EA | |
| TURNAROUND | | |
| | | 50,000 |
| 1030AH | CONDUCT LOW VOLTAGE ELECTRONIC LEAK | SF | |
| DETECTION TESTING ON MEMBRANE ROOF | | |
| SYSTEMS | | |
1031 MISCELLANEOUS 1,000
1031AA DRYVIT CUT/PATCH SF 950
| 1031AB | CUT AND REPOINT MASONRY (BRICK | LF | |
| AND BLOCK) | | 500 |
1031AC CUT AND REPOINT MASONRY (STONE) LF 1,250
| 1031AD | CUT AND PATCH COATED FOAM ROOF TO 1" | SF | |
| DEEP | | 250 |
| 1031AE | INSTALL "RIDGE IT" ANCHOR SYSTEM ON | EA |
| SLOPED ROOF SYSTEMS | |
1032 TEMPORARY SCAFFOLDING 100
| 1032AA | CONSTRUCT FREE STANDING TEMPORARY | VLF | |
| SCAFFOLDING STAIR TOWER TO PROVIDE SAFE | | |
| ACCESS TO ROOF (Vertical linear feet) | | |
| UP TO 25 VERTICAL LINEAR FEET | | 100 |
| 1032AB | CONSTRUCT FREE STANDING TEMPORARY | VLF | |
| SCAFFOLDING STAIR TOWER FOR ROOF | | |
| ACCESS 26 TO 35 VERTICAL LINEAR FEET | | 100 |
| 1032AC | CONSTRUCT FREE STANDING TEMPORARY | VLF | |
| SCAFFOLDING STAIR TOWER FOR ROOF | | |
| ACCESS 36 TO 45 VERTICAL LINEAR FEET | | 100 |
| 1032AD | CONSTRUCT FREE STANDING TEMPORARY | VLF | |
| SCAFFOLDING STAIR TOWER FOR ROOF ACCESS | | |
| ACCESS 46 VLF AND GREATER | | 100 |
| 1032AE | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | |
| STAIR TOWER FOR ROOF ACCESS | | |
| UP TO 25 VERTICAL LINEAR FEET | | 100 |
| 1032AF | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | |
| STAIR TOWER FOR ROOF ACCESS | | |
| 26 VLF TO 35 VLF | | 100 |
| 1032AG | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | |
| STAIR TOWER FOR ROOF ACCESS | | |
| 36 VLF TO 45 VLF | | 100 |
| 1032AH | CONSTRUCT FIXED TEMPORARY SCAFFOLDING | VLF | |
| STAIR TOWER FOR ROOF ACCESS | | |
| 46 VLF AND GREATER | | 100 |
| 1032AI | CONSTRUCT FREE STANDING, TEMPORARY | CSF | |
| SCAFFOLDING AROUND BUILDING PERIMETER | | |
| TO SUPPORT ROOF WORK. Price to include | | |
| walk boards, rails, toe boards and outriggers (as | | |
| required) | | 100 |
| 1032AJ | CONSTRUCT FIXED (ATTACHED TO BUILDING ) | CSF |
| TEMPORARY SCAFFOLDING AROUND BUILDING | |
| PERIMETER TO SUPPORT ROOF WORK. Price to | |
| include walk boards, rails, toe boards and out riggers | |
| (as required) | |
1033 SNOW GUARDS & VENTILATORS 100
| 1033AA | COPPER SNOW GUARD, NO. 100 BB | EA | |
| INSTALLED IN CONJUNCTION WITH | | |
| INSTALLATION OF NEW SLATE OR | | |
| MANUFACTURED SLATE 630 LBS. EA, | | |
| BRASS CLEAT .O80 THICK 1/2 HARD | | |
| COPPER CLEAT (SHOE) .050 THICK | | 700 |
| 1033AB | INSTALL MECHANICALLY FASTENED, CLEAR | EA | |
| POLYCARBONATE SNOW AND ICE GUARDS ON | | |
| SLOPED ROOF SYSTEMS (SNO-BLX™ , SNO-JAX™ | | |
| OR AN APPROVED EQUIVALENT) | | 300 |
| 1033AC | INSTALL MECHANICALLY FASTENED ALUMINUM | EA | |
| SNOW AND ICE GUARDS ON SLOPED ROOF | | |
| SYSTEMS | | 300 |
| 1033AD | INSTALL MECHANICALLY FASTENED STAINLESS | EA | |
| STEEL SNOW AND ICE GUARDS ON SLOPED ROOF | | |
| SYSTEMS | | 2,000 |
| 1033AE | INSTALL DOUBLE RAIL SNOW FENCE WITH ICE | LF | |
| CLIPS TO METAL ROOF SYSTEMS 3/12 PITCH OR | | |
| GREATER (S-5! CLIPS ANF TWO RAIL SNOW-FENCE | | |
| ™ WITH SNO-CLIPS ™ OR APPROVED EQUIVALENT) | | 2,000 |
| 1033AF | INSTALL S-5! BRACKET (OR EQUIVALENT) WITH | EA | |
| RAM-GUARD ™ SNOW RETENTION DEVICE (OR | | |
| EQUIVALENT) TO METAL ROOF SYSTEMS 3/12 | | |
| PITCH OR GREATER | | 3,250 |
| 1033AG | REMOVAL, DISPOSE AND REPLACE OR | LF | |
| INSTALL NEW ROOF RIDGE VENTILATOR | | 1,000 |
| 1033AH | REMOVE AND DISPOSE OF METAL ROOF | CF | |
| VENTILATORS. REMOVE VENTILATOR | | |
| AND ALL ASSOCIATED HARDWARE. TURN | | |
| ALL METAL INTO METAL SALVAGE | | 50 |
| 1033AJ | DISCONNECT AND RECONNECT HVAC UNIT | EA | |
| (1-3 TON) TO RAISE 18" MINIMUM TO | | |
| INCLUDE ALL PIPING, ELECTRICAL, | | |
| CURBING AND STEEL | | 100 |
| 1033AK | PROVIDE GALVANIZED RAIN HOOD | SF | |
| AROUND STACKS | | 20 |
1033AL 8" TURBINE VENTILATOR EA 45
1033AM 14" TURBINE VENTILATOR EA 500
| 1033AN | REMOVE AND DISPOSE OF ABANDONED ROOF | CF |
| MOUNTED EQUIPMENT AND CURBS TO INCLUDE | |
| ELECTRICAL ISOLATION AND DISCONNECT FROM | |
| SOURCE PANEL AS APPLICABLE. | |
1034 LIGHTENING PROTECTION SYSTEMS 500
| 1034AA | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | |
| PROTECTION SYSTEM (LPS) AIR TERMINAL | | |
| COPPER AND/OR ALUMINUM | | 750 |
| 1034AB | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | |
| PROTECTION SYSTEM (LPS) MOUNTING BRACKET | | |
| COPPER AND/OR ALUMINUM | | 1,250 |
| 1034AC | REMOVE, SALVAGE AND REINSTALL LIGHTENING | EA | |
| PROTECTION SYSTEM (LPS) COMPONENTS AND | | |
| CONDUCTORS, COPPER AND/OR ALUMINUM | | 5 |
| 1034AD | PERFORM CONTINUITY AND ACCEPTANCE |
| TESTING FOR LIGHTENING PROTECTION SYSTEM |
| AFTER REINSTALLATION |
1035 MISCELLANEOUS SAFETY EQUIPMENT 5
| 1035AA | REMOVE, DISPOSE AND REPLACE OR INSTALL | EA | |
This is the start of the file's text. The full file is on GovTribe.