Attachment_0010_ATPD_2336D_to_ATPD_2336G_Changes.pdf

PDF 90 KB Posted

Attached to
PUMP RACK MODULE (PRM) - LUBRICATION AND FUEL DISPENSING EQUIPMENT
Solicitation number
W56HZV17R0031
Issued by

About this file

Attachment 0010 ATPD 2336D to ATPD 2336G Changes

View the file

Other files

File Type Posted
JA_-_PRM_for_PdM_PAWSv_2017-058_Redaction.pdf PDF
W56HZV17R0031-0002.pdf PDF
Attachment_0011_PRM_Fault_Indicators.pdf PDF
Attachment_0005_OBS_rev1.docx DOCX document
Attachment_0004_Special_Tools_rev1.docx DOCX document
Attachment_0003_COEI_rev1.docx DOCX document
Attachment_0002_ASL_rev_1.pdf PDF
Attachment_0001_BII_rev1.docx DOCX document
W56HZV17R0031-0001.pdf PDF
Attachment_0007_PRM_FAT_plan.pdf PDF
Pump_Rack_Module_W56HZV-17-R-0031.pdf PDF
Attachment_0007_PRM_FAT_plan.pdf PDF
Attachment_0008-_S&SI.pdf PDF
Attachment_0005_OBS.pdf PDF
Attachment_0004_Special_Tools.pdf PDF
Attachment_0003_COEI.pdf PDF
Attachment_0002_ASL.pdf PDF
Attachment_0001_BII.pdf PDF
Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FROM:

3.5.9.2 Fuel dispensing nozzle. Each TRM shall be equipped with one 1-inch fuel nozzle IAW A-A 52030 type I, class A, style 2 to refuel vehicles. The nozzle shall be provided with a caution tag to prevent confusion with other nozzles in the system. Each PRM shall be equipped with eight single point refueling, D-1 type nozzles, equipped with a 100 mesh screen, IAW SAE-AS-5877, two closed circuit refueling (CCR) nozzles for aircraft refueling IAW MIL- PRF-52747, eight 1.5-inch automatic shut-off open port nozzles, and four 1-inch automatic shut-off open port nozzles IAW A-A-52030 type 2, class A, style 2. All nozzles shall be equipped with a bonding and grounding cable assembly.

TO:

3.5.9.2 Fuel dispensing nozzle. Each TRM shall be equipped with one 1-inch (25 mm) automatic shut-off fuel nozzle IAW A-A 52030 type II, class A, style 2 to refuel vehicles. The nozzle shall be provided with a caution tag to prevent confusion with other nozzles in the MFS.

Each PRM shall be equipped with four single point refueling, D-1 type nozzles, equipped with a 100 mesh screen, IAW SAE-AS-5877, two closed circuit refueling (CCR) nozzles for aircraft refueling IAW MIL-PRF-52747, eight 1.5-inch (38 mm) automatic shut-off open port nozzles, and four 1-inch (2.54 cm) automatic shut-off open port nozzles IAW A-A-52030 type II, class A, style 2. All nozzles shall be equipped with a bonding and grounding cable assembly. The 1-inch nozzles provided for the PRM and TRM shall prevent overfilling of the vehicle’s fuel tank and shall automatically shut off when falling out of the filler neck of the vehicle’s fuel tank.

3.5.7.5 Grounding and bonding. The MFS shall have complete electrical continuity (bonding) throughout the system when in operational service configuration. This includes all electrically conductive components of the MFS that the fluid and the operator may come in contact with. All bonding and/or grounding connections shall be mechanically secure and shall measure 1 (one) ohm or less. Two manual reels each with one 15-ft grounding wire and plier-type clamps shall be provided for each TRM and each PRM.

3.5.7.5 Grounding and bonding. The MFS shall have complete electrical continuity (bonding) throughout the system when in operational service configuration. This includes all electrically conductive components of the MFS which the fluid and the operator may come in contact with. All bonding and/or grounding connections shall be mechanically secure and electrical resistance between the pumping assembly, the tank, lower frame, dispensing ports, 2-inch (5.1 cm) dispensing hoses, grounding reels, and grounding rods shall measure 10 (ten) ohms or less. A minimum of one self-retracting reel with one 15-foot (4.57 m) grounding wire and plier-type clamps shall be provided for each TRM and each PRM. In addition, four 25-foot (7.62 m) grounding cable assemblies shall be provided for each PRM.

3.5.7.2.1.1 PRM Adapters/Reducers.

(2) 2-inch unisex to 2-inch female cam-lock adapter

(2) 2-inch unisex to 2-inch male cam-lock adapter

(2) 4-inch female to 2-inch male cam-lock reducer

(1) 4-inch female to 3-inch male cam-lock reducer

(1) 6-inch male to 4-inch female cam-lock reducer

3.5.7.2.1.1 PRM adapters/reducers/dust caps.

(2 each) 2-inch (5.1 cm) dry quick-disconnect, sexless to 2-inch (5.1 cm) female cam-lock adapter (2 each) 2-inch (5.1 cm) dry quick-disconnect, sexless to 2-inch (5.1 cm) male cam-lock adapter (2 each) 4-inch (10.2 cm) female to 2-inch (5.1 cm) male cam-lock reducer (1 each) 4-inch (10.2 cm) female to 3-inch (7.6 cm) male cam-lock reducer (1 each) 4-inch (10.2 cm) male to 4-inch (10.2 cm) male cam-lock adapter (1 each) 6-inch (15.2 cm) male to 4-inch (10.2 cm) female cam-lock reducer (1 each) 3-inch (7.62 cm) to 2-inch (5.1 cm) dry quick-disconnect, sexless reducer.

(2 each) 4-inch (10.2 cm) female cam-lock dust caps.

3.5.6.2.1 Pumping assembly. The pumping assembly shall consist of a self-priming pump and a power source. The pumping assembly shall be easily removable from its module for maintenance purposes.

3.5.6.2.1 Pumping assembly. The pumping assembly shall consist of a self-priming pump and an engine. The pumping assembly shall be easily removable from its module for maintenance purposes. The pumping assembly shall be provided with a funnel for the purpose of manually priming the pump.

3.10.2 Markings. Markings shall be black lusterless paint, conforming to MIL-DTL- 53039 or MIL-DTL-53072. The following markings shall be applied to the MFS:

a. "NO STEP", read from walking surface on top of the tank, shall be stenciled on the top of the tank adjacent to the catwalk, in black 4-inch block letters.

b. Each side of the TRM and the operator's end shall be stenciled with the following in an area of unobstructed visibility: "FLAMMABLE" in 4-inch block letters and "NO SMOKING WITHIN 50 FEET" in 2-inch block letters.

c. The following messages shall be stenciled in 2-inch block letters adjacent to the forklift pockets: "FORK LIFT EMPTY ONLY" and "USE 8 FOOT TINES

ONLY".

d. The following shall be stenciled in plain view on or near the manhole cover:

"DANGER - Confined Space, Do Not Enter" "Refer to Technical Manual"

3.10.2 Markings. Markings shall be black lusterless paint, conforming to MIL-DTL- 53039 or MIL-DTL-53072. The following markings shall be applied to the MFS:

a. "NO STEP", read from walking surface on top of the tank, shall be stenciled on the top of the tank adjacent to the catwalk, in black 4-inch block letters.

b. Each side of the TRM and the operator's end shall be stenciled with the following in an area of unobstructed visibility: "FLAMMABLE" in 4-inch block letters and "NO SMOKING WITHIN 50 FEET" in 2-inch block letters.

c. The following messages shall be stenciled in 2-inch block letters adjacent to the forklift pockets: "FORK LIFT EMPTY ONLY".

d. The following shall be stenciled in plain view on or near the manhole cover:

"DANGER - Confined Space, Do Not Enter" "Refer to Technical Manual"

File details come from the government source that posted it.