Attachment_0018_-_RCIS_Type_I_Test_Summary.xlsx
XLSX spreadsheet 229 KB Posted
- Attached to
- Route Clearance Interrogation System (RCIS)
- Solicitation number
- W56HZV15R0156
About this file
Draft RCIS Attachment A0018
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EMD Test Schedule
TBD
LRIP Test Schedule
TBD
RCIS I EMD LRIP Test Articles
| RCIS Type I EMD/LRIP Test Matrix | |||||||
| GFE to SAC Contractor | SAC Contractor Role | Test Article Qty | GOV Test site Location | Delivery Date | Test Article Refurbishment | Comments | |
| EMD Contract Award | 1 QTY HMEE-I + 1 QTY MPCV | Utilize GFE vehicles to support PDR | Contractor will deliver a total of 7 QTY SAC systems, of which 6 QTY (SAC systems) will be integrated on RCIS Type I Systems or RCIS Type I Systems w/SCVs | ||||
| GOV SIL | Contractor ships 1 QTY SAC system to support Government SIL | 1 QTY RCIS Type I System | TACOM Warren | Prior to CDR | This does not include any vehicles, Contractor is only providing SAC B-Kit, laboratory cables and other necessary equipment/components | ||
| Design & Integration | 5 QTY HMEE-I + 2 QTY MPCV + 3 QTY SCV | Contractor integrates 6 QTY SAC Systems to yield 3 QTY RCIS Type I System + 3 QTY RCIS Type I System w/SCV | Control Vehicle Mitigation Plan is to utilize surrogate (M1114/RG-31) control vehicles (SCV) incase MPCVs are not available. | ||||
| Contractor Shakedown Test | 3 QTY RCIS Type I System + 3 QTY RCIS Type I System w/SCV | All vehicle sets will undergo Contractor shakedown testing prior to Government delivery to (Government) test sites | |||||
| Contractor Facility Vehicle | Contractor maintains 1 QTY RCIS Type I System w/SCV per approved baseline configuration | Contractor Facility vehicle will be used for troubleshooting, Logistics support and maintenance of approved baseline configuration. | |||||
| RAM | Contractor ships vehicles to Government test site location with FSR support | 1 QTY RCIS Type I System + 1 QTY RCIS Type I System w/SCV | Aberdeen Test Center (ATC), Aberdeen Proving Ground (APG), MD | ||||
| PPQT | Contractor ships vehicles to Government test site locations with FSR support | 2 QTY RCIS Type I System + 1 QTY RCIS Type I System w/SCV | 1) Performance - ATC, APG, MD | ||||
| 2) Electromagnetic Environmental Effects (E3) - White Sands Test Center, White Sands, NM | |||||||
| 3) Option A: Environmental Effects - Yuma Proving Ground, AZ | |||||||
| 3) Option B: Environmental Effects - Cold Region Test Center, Ford Greely, AK | |||||||
| 4) Dugway Proving Ground (CBDRN Decontamination and Compatibility Paper Study), Dugway Proving Ground, UT | |||||||
| LUT | Contractor refurbishes 2 QTY RCIS Type I System to 10/20 Standard prior to LUT | 2 QTY RCIS Type I System | TBD; potentially FT. Hood | 2 QTY RCIS Type I prior to LUT | LUT requires 2 QTY RCIS Type I System System per OMS-MP. 2 QTY Husky Mounted Detected Systems required per MSCoE. | ||
| Total EMD Shipment for GOV testing | 3 QTY RCIS Type I System + 2 QTY RCIS Type I System w/SCV | Contractor facility vehicle excluded from total, but can be repurposed for government performed testing if needed |
| LRIP Contract Award | Contractor produces and delivers LRIP versions of the RCIS Type I Systems | ||||
| Contractor Facility Vehicle | Contractor maintains 1 QTY RCIS Type I System w/SCV per approved baseline configuration | Contractor Facility vehicle will be used for troubleshooting and Logistics support. | |||
| PQT | 2 QTY RCIS Type I System | 1) Performance - ATC, APG, MD | Assumes that PQT vehicle cannot be repurposed for IOT (no refurbishment) | ||
| 2) E3 - White Sands Test Center, White Sands, NM | |||||
| 3) Environmental Effects - Yuma Test Center, Yuma Proving Ground, AZ | |||||
| RAM | 4 QTY RCIS Type I System | ATC, APG, MD | LRIP RAM test articles increased to 4 HMEE-Is and 4 MPCVs w/SAC system based off the following: (1) The limited availability of MPCVs during EMD testing may not generate sufficient RAM test runs (2) Having 4 test articles may be necessary due to the short length of our PQT phase (per RCIS Type I program schedule on 19MAR2015) or else RAM will parellel PQT, LOG Demo and IOT | ||
| LOG Demo | 1 QTY RCIS Type I System | Need to confirm vehicle qty and configuration with ALUGS LOG | |||
| IOT | Contractor shall refurbish 11 QTY RCIS Type I Systems to 10/20 Standard after competion of IOT | 4 QTY RCIS Type I System | TBD; potentially Ft. Hood | Yes, after completion of IOT | Based off OTC estimate from Cathy Miller; used HMDS as reference. Need to cross-check OMS/MP for test article quantity. |
| Total LRIP Shipment to Gov test site locations | 11 QTY RCIS Type I System | Contractor facility vehicle excluded from total, but can be repurposed for government performed testing if needed |
| Key | |
| Nomenclature | Definition |
| RCIS Type I System | |
| SAC System | |
| RCIS Type I System w/SCV | A Surrogate Control Vehicle (SCV) can be any military vehicle (i.e., HMMWV M1114, RG-31, FMTV, etc). |
EMD Test Assumptions
TBD
LUT Activities
TBD
IOT Activities
TBD
Contractor Test Support
| Contractor Test Support | |
| Contractor System Support Package (SSP) required all test phase | Spare and Repair Parts |
| Technical Manuals | |
| Test Site Personnel operator and maintenance training | |
| Field Service Representative (FSR) | |
| Vehicle Deprocessing | |
| SSP established at Aberdeen Test Center, MD and Yuma Test Center, AZ | |
| Support of Western Test Sites (Electronic Proving Ground, AZ, White Sands Missle Range, NM and Dugway Proving Ground) out of Yuma | |
| XXXXX Cold Regions Test Center, AK, and Tropic Regions Test Center | |
| Operational Test Support | Operator and New Equipment (NET) provided to Soldier test participants for LUT during EMD |
| Spare and Repair Parts package provided to test site for LUT and IOT (location TBD) | |
| Maintenance of all RCIS Type I System & RCIS Type I System w/SCV during LUT. Organic unit Maintenance during IOT. | |
| Operator and Field Level Maintenance NET provided to Soldier test participants for IOT during LRIP | |
| Other Contractor Support | Safety Assessment Report (SAR) on RCIS Type I system ---what about SCV? |
| Tranportability analysis and report on RCIS Type I system and RCIS Type I system w/SCV | |
| Support to all Test IPT meetings and Test Readiness Reviews | |
| Test Incident Report (TIR) response and Failure Analysis Corrective Action Report development. | |
| Refurbish 2 QTY RCIS Type I System to 10/20 Standard prior to LUT | |
| Refurbish all RCIS Type I systems after IOT |
Test Site Shipping Address
| Test Site | Shipping Address |
| Aberdeen Test Center (APG) | US ARMY Aberdeen Test Center (XXXXXX) |
| ATTN: TEDT-AT-ADF | |
| 400 Colleran Road | |
| Aberdeen Proving Ground, MD 21005-5059 | |
| Yuma Test Center (YPG) | Commander (XXXXXX) |
| US ARMY Yuma Proving Grounds | |
| Transportation Office, BLDG 2660 | |
| ATTN: TEDT-YPY-CAC | |
| Yuma, AZ 85365 | |
| White Sands Missle Range (WSMR) | Commander US Army White Sands Missle Range (XXXXX) |
| ATTN: TEDT-WSV-N | |
| BLDG 21225 | |
| White Sands Missile Range, NM 88002-5158 | |
| Electronic Proving Ground (EPG(EPG)) | Electronic Proving Ground |
| E3 Facility | |
| ATTN: TEDT-EP-SEA | |
| Ft. Huachuca, AZ 85613-7063 | |
| FT Hood | PdM ALUGS Fielding Team (XXXXX) |
| UMFP Warehouse Bldg 88004 Clark Road & Logistics Lane | |
| Ft. Hood, TX 76544-6000 |
image1.png image2.png
File details come from the government source that posted it. Updated .