Attachment_0018_-_RCIS_Type_I_Test_Summary.xlsx

XLSX spreadsheet 229 KB Posted

Attached to
Route Clearance Interrogation System (RCIS)
Solicitation number
W56HZV15R0156
Issued by

About this file

Draft RCIS Attachment A0018

View the file

Other files

File Type Posted
FCL_Sponsorship_Letter_OCT15.pdf PDF
FCL_Notice.docx DOCX document
FCL_Orientation_Handbook_18FEB15.pdf PDF
Q&A_Tracker_2-23-17.pdf PDF
Q&A_Tracker_12-29-16.pdf PDF
RCIS_Vehicle_Viewing_Pictures__HMEE_CAD_Models_and_Data_Information.pdf PDF
RCIS_Acq_Strategy_Notice_Revision_2.pdf PDF
Attachment_0037_-_Small_Business_Participation_Workbook_10-13-16.xlsx XLSX spreadsheet
Attachment_0054_-_Certification_of_Small_Business_Size_and_Socioeconomic_Status_for_Subcontractors.docx.pdf PDF
Attachment_0036_-_Small_Business_Participation_Workbook_Instructions__R2.pdf PDF
RCIS_Type_I_Vehicle_Viewing_Participants.pdf PDF
Q A_Tracker_Batch_1.pdf PDF
RCIS_Type_I_Vehicle_Viewing_Invitation_Revision_1.docx DOCX document
Questions_and_Comments_from_Industry_on_the_Route_Clearance__Interrogation_System_(RCIS)_Program.pdf PDF
JCB_Organizational_Conflict_of_Interest.pdf PDF
Pre-Solicitation_Conference_List_of_Attendees.pdf PDF
RCIS_Pre-Solicitation_Conf_Slides.pdf PDF
One-on-One_Questions.pdf PDF
Attachment_0044_-_Soldier_Workload_Instructions.docx DOCX document
Attachment_0043_-_HFEA_Instructions.docx DOCX document
Attachment_0045_-_HSIP_Instructions.docx DOCX document
Attachment_0039_-_TM_Crosswalk.xls XLS spreadsheet
Attachment_0046_-_DOORS_DPA_Format.docx DOCX document
Attachment_0032_-_SSv_Severity_Scale.ppt PPT presentation
Attachment_0048_-_HSI_Event_Report_Instructions.docx DOCX document
Attachment_0038_-_Equipment_Publications_Defects_List.doc DOC document
Attachment_0036_-_Small_Business_Participation_Workbook_Instructions.docx DOCX document
Attachment_0023_-_Production_Government_Format_Technical_Data_Package_(TDP).docx DOCX document
Attachment_0021_-_Developmental_Contractor_Format_Technical_Data_Package_(TDP).docx DOCX document
Attachment_0006_-_RCIS_Type_I_Work_Breakdown_Structure_(WBS).xlsx XLSX spreadsheet
Attachment_0011_-_Performance_Work_Statement_Applicable_Documents.docx DOCX document
Attachment_0007_-_Performance_Work_Statement_Acronyms.docx DOCX document
RCIS_Type_I_PWS.pdf PDF
RCIS_Type_I_CDRL.pdf PDF
Attachment_0014_-_UGV_Interoperability_Profile_(IOP).pdf PDF
Attachment_0024_-_DD_254_RCIS_Type_I_W56HZV-15-R-0156.pdf PDF
Attachment_0008_-_Government_Furnished_Property_(GFP)_List.pdf PDF
RCIS_Acq_Strategy_Notice_Revised.pdf PDF
Postponed_Announcement_-_RCIS_Pre-Solicitation_Conference.docx DOCX document
Postponed_Announcement_-_RCIS_Pre-Solicitation_Conference.docx DOCX document
RCIS_Pre-Solicitation_Conf_Invitation_(Revision_1).docx DOCX document
RCIS_Acq_Strategy_Notice_2016.docx DOCX document
RCIS_Pre-Solicitation_Conf_Invitation.docx DOCX document
attach0006.XLSX XLSX spreadsheet
attach0010.docx DOCX document
EMD-SOW.pdf PDF
attach0008.pdf PDF
attach0018.docx DOCX document
attach0012.xlsx XLSX spreadsheet
attach0016.pdf PDF
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

EMD Test Schedule

TBD

LRIP Test Schedule

TBD

RCIS I EMD LRIP Test Articles

RCIS Type I EMD/LRIP Test Matrix
GFE to SAC ContractorSAC Contractor RoleTest Article QtyGOV Test site LocationDelivery DateTest Article RefurbishmentComments
EMD Contract Award1 QTY HMEE-I + 1 QTY MPCVUtilize GFE vehicles to support PDRContractor will deliver a total of 7 QTY SAC systems, of which 6 QTY (SAC systems) will be integrated on RCIS Type I Systems or RCIS Type I Systems w/SCVs
GOV SILContractor ships 1 QTY SAC system to support Government SIL1 QTY RCIS Type I SystemTACOM WarrenPrior to CDRThis does not include any vehicles, Contractor is only providing SAC B-Kit, laboratory cables and other necessary equipment/components
Design & Integration5 QTY HMEE-I + 2 QTY MPCV + 3 QTY SCVContractor integrates 6 QTY SAC Systems to yield 3 QTY RCIS Type I System + 3 QTY RCIS Type I System w/SCVControl Vehicle Mitigation Plan is to utilize surrogate (M1114/RG-31) control vehicles (SCV) incase MPCVs are not available.
Contractor Shakedown Test3 QTY RCIS Type I System + 3 QTY RCIS Type I System w/SCVAll vehicle sets will undergo Contractor shakedown testing prior to Government delivery to (Government) test sites
Contractor Facility VehicleContractor maintains 1 QTY RCIS Type I System w/SCV per approved baseline configurationContractor Facility vehicle will be used for troubleshooting, Logistics support and maintenance of approved baseline configuration.
RAMContractor ships vehicles to Government test site location with FSR support1 QTY RCIS Type I System + 1 QTY RCIS Type I System w/SCVAberdeen Test Center (ATC), Aberdeen Proving Ground (APG), MD
PPQTContractor ships vehicles to Government test site locations with FSR support2 QTY RCIS Type I System + 1 QTY RCIS Type I System w/SCV1) Performance - ATC, APG, MD
2) Electromagnetic Environmental Effects (E3) - White Sands Test Center, White Sands, NM
3) Option A: Environmental Effects - Yuma Proving Ground, AZ
3) Option B: Environmental Effects - Cold Region Test Center, Ford Greely, AK
4) Dugway Proving Ground (CBDRN Decontamination and Compatibility Paper Study), Dugway Proving Ground, UT
LUTContractor refurbishes 2 QTY RCIS Type I System to 10/20 Standard prior to LUT2 QTY RCIS Type I SystemTBD; potentially FT. Hood2 QTY RCIS Type I prior to LUTLUT requires 2 QTY RCIS Type I System System per OMS-MP. 2 QTY Husky Mounted Detected Systems required per MSCoE.
Total EMD Shipment for GOV testing3 QTY RCIS Type I System + 2 QTY RCIS Type I System w/SCVContractor facility vehicle excluded from total, but can be repurposed for government performed testing if needed
LRIP Contract AwardContractor produces and delivers LRIP versions of the RCIS Type I Systems
Contractor Facility VehicleContractor maintains 1 QTY RCIS Type I System w/SCV per approved baseline configurationContractor Facility vehicle will be used for troubleshooting and Logistics support.
PQT2 QTY RCIS Type I System1) Performance - ATC, APG, MDAssumes that PQT vehicle cannot be repurposed for IOT (no refurbishment)
2) E3 - White Sands Test Center, White Sands, NM
3) Environmental Effects - Yuma Test Center, Yuma Proving Ground, AZ
RAM4 QTY RCIS Type I SystemATC, APG, MDLRIP RAM test articles increased to 4 HMEE-Is and 4 MPCVs w/SAC system based off the following: (1) The limited availability of MPCVs during EMD testing may not generate sufficient RAM test runs (2) Having 4 test articles may be necessary due to the short length of our PQT phase (per RCIS Type I program schedule on 19MAR2015) or else RAM will parellel PQT, LOG Demo and IOT
LOG Demo1 QTY RCIS Type I SystemNeed to confirm vehicle qty and configuration with ALUGS LOG
IOTContractor shall refurbish 11 QTY RCIS Type I Systems to 10/20 Standard after competion of IOT4 QTY RCIS Type I SystemTBD; potentially Ft. HoodYes, after completion of IOTBased off OTC estimate from Cathy Miller; used HMDS as reference. Need to cross-check OMS/MP for test article quantity.
Total LRIP Shipment to Gov test site locations11 QTY RCIS Type I SystemContractor facility vehicle excluded from total, but can be repurposed for government performed testing if needed
Key
NomenclatureDefinition
RCIS Type I System
SAC System
RCIS Type I System w/SCVA Surrogate Control Vehicle (SCV) can be any military vehicle (i.e., HMMWV M1114, RG-31, FMTV, etc).

EMD Test Assumptions

TBD

LUT Activities

TBD

IOT Activities

TBD

Contractor Test Support

Contractor Test Support
Contractor System Support Package (SSP) required all test phaseSpare and Repair Parts
Technical Manuals
Test Site Personnel operator and maintenance training
Field Service Representative (FSR)
Vehicle Deprocessing
SSP established at Aberdeen Test Center, MD and Yuma Test Center, AZ
Support of Western Test Sites (Electronic Proving Ground, AZ, White Sands Missle Range, NM and Dugway Proving Ground) out of Yuma
XXXXX Cold Regions Test Center, AK, and Tropic Regions Test Center
Operational Test SupportOperator and New Equipment (NET) provided to Soldier test participants for LUT during EMD
Spare and Repair Parts package provided to test site for LUT and IOT (location TBD)
Maintenance of all RCIS Type I System & RCIS Type I System w/SCV during LUT. Organic unit Maintenance during IOT.
Operator and Field Level Maintenance NET provided to Soldier test participants for IOT during LRIP
Other Contractor SupportSafety Assessment Report (SAR) on RCIS Type I system ---what about SCV?
Tranportability analysis and report on RCIS Type I system and RCIS Type I system w/SCV
Support to all Test IPT meetings and Test Readiness Reviews
Test Incident Report (TIR) response and Failure Analysis Corrective Action Report development.
Refurbish 2 QTY RCIS Type I System to 10/20 Standard prior to LUT
Refurbish all RCIS Type I systems after IOT

Test Site Shipping Address

Test SiteShipping Address
Aberdeen Test Center (APG)US ARMY Aberdeen Test Center (XXXXXX)
ATTN: TEDT-AT-ADF
400 Colleran Road
Aberdeen Proving Ground, MD 21005-5059
Yuma Test Center (YPG)Commander (XXXXXX)
US ARMY Yuma Proving Grounds
Transportation Office, BLDG 2660
ATTN: TEDT-YPY-CAC
Yuma, AZ 85365
White Sands Missle Range (WSMR)Commander US Army White Sands Missle Range (XXXXX)
ATTN: TEDT-WSV-N
BLDG 21225
White Sands Missile Range, NM 88002-5158
Electronic Proving Ground (EPG(EPG))Electronic Proving Ground
E3 Facility
ATTN: TEDT-EP-SEA
Ft. Huachuca, AZ 85613-7063
FT HoodPdM ALUGS Fielding Team (XXXXX)
UMFP Warehouse Bldg 88004 Clark Road & Logistics Lane
Ft. Hood, TX 76544-6000

image1.png image2.png

File details come from the government source that posted it. Updated .