TE H- Government Furnished Facilites_27Jan2026.xlsx
XLSX spreadsheet 17 MB Posted
- Solicitation number
- W51EW726RA004
- Issued by
-
Department of the Army
About this file
This is a Government Furnished Facilities (GFF) inventory document that catalogs real property and buildings available to contractors supporting the US Army Operational Evaluation Command (OEC), formerly known as Operational Test Command. The document lists approximately 119,270 square feet of total real property across multiple facilities located at the test site, including administrative buildings, maintenance shops, warehouses, storage bunkers, motor pool complexes, and instrumentation yards. Key facilities include Building 91002 (36,867 sq ft headquarters/admin building constructed in 1969), Motor Pool Building 94010 (16,452 sq ft vehicle maintenance shop from 1995), Motor Pool Building 94020 (23,936 sq ft warehouse for tests from 1995), Motor Pool Building 94015 (26,055 sq ft instrumentation/electronics warehouse from 1995), and Forward Test Center (FTC) facilities with multiple test support buildings. The facilities are categorized by function using CAT codes and designated as either contractor-operated or government-maintained spaces.
The document provides a comprehensive mapping of available infrastructure for the Base Test Support Services (BTSS) follow-on contract (Solicitation W51EW726RA004), which is currently in pre-solicitation phase as a Draft RFP. The facilities support various operational test and evaluation activities including vehicle maintenance, equipment storage, hazmat storage, instrumentation installation, and test team operations. The inventory includes specific square footage, building numbers, construction years, and facility classifications to enable potential contractors to understand the physical plant available for support operations. RFI submissions regarding the DRFP are due by February 6, 2026, to the Army contracting team.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| BTSS DRFP Follow Up_Government Responses_posted 02Mar2026.xlsx | XLSX spreadsheet | |
| DRFP W51EW726RA004_RFI Responses_Posted 13Feb2026.xlsx | XLSX spreadsheet | |
| Attachment 5_Historical Data_Apr 2021-Mar 2025.xlsx | XLSX spreadsheet | |
| RFI Template_DRFP W51EW726RA004.xlsx | XLSX spreadsheet | |
| DRAFT_RFP W51EW726RA004_posted 02Feb2026.pdf | ||
| Attachment 4_Pricing Matrix_29Jan2026.xlsx | XLSX spreadsheet | |
| TE E _BTSS_DD254.pdf | ||
| TE C DD1423 A001 Block 16 Continuation Sheet.pdf | ||
| TE F-IML Listing.XLSX | XLSX spreadsheet | |
| TE D GFP_as of 27Jan2026.xlsx | XLSX spreadsheet | |
| Attachment 2_Sample Test_SOW-M10_BCV_IOT.pdf | ||
| Attachment 6_WGDs_as of 03Dec2025.pdf | ||
| Attachment 3_PPQ_13Jan2026.docx | DOCX document | |
| TE H- Government Furnished Facilites_27Jan2026.xlsx | XLSX spreadsheet | |
| Attachment 1_BTSS PWS_30Jan2026.pdf | ||
| TE G OTC BTSS Military Test Locations List.pdf | ||
| Attachment 5_Historical Data_Apr 2021-Mar 2025.xlsx | XLSX spreadsheet | |
| TE C DD1423_BTSS_27Jan2026.pdf |
Show all 18
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Fac. Log
| Building Name | Building Number | Square Feet | CAT CODE | Facility Class: | Address | Year Built | Used For |
| AVTD, MTD, SCIF | 91002 | 36867 | 31920-LAB/TST GP | 533 W HEADQUARTERS AVE | 1969 | ADMIN/MTD/AVTD/SCIF | |
| Westech Admin | 91024 | 4093 | 31920-LAB/TST GP | 388 W HEADQUARTERS AVE | 2007 | ADMIN- PM TSC | |
| Gardner Shop/Maintenance | 91059 | 4086 | 21885- MNT GP | Multi-use bldg: 21885 (Main. Gen.)1345 sq. ft. 31920 lab/test 2741 sq. ft. | 424 MUSTANG RD | 1969 | A/C REPAIR/ LAB LAB/TST-TSC |
| Wash Station | 91064 | 1 | 14955- WASH PLAT ORG | Wash platform @ 91065 | 1969 | WASHRACK- FAC DIV. | |
| Old Gardner Shop | 91065 | 1003 | 31410- GND TRAN EQP | 320 MUSTANG RD | 1969 | GROUNDS SHOP- FAC DIV. | |
| Bunker | 92161 | 2857 | 31720- DETECT EQ | 1241 SUPPLY RD | 1969 | STORAGE BUNKER | |
| Motor Pool | 94010 | 16452 | 31410- GND TRAN EQP | 439 OUTER FENCE RD | 1995 | GND TRAN EQP-TSC | |
| Motor Pool | 94012 | 36 | 14113- ACCESS CNT | 439 OUTER FENCE RD | 1995 | GUARDHOUSE- TSC | |
| Motor Pool | 94014 | 356 | 44228- HAZ MAT STR INS | 439 OUTER FENCE RD | 1995 | HAZMAT STORAGE- TSC | |
| Motor Pool | 94015 | 26055 | 21885- MNT GP | 439 OUTER FENCE RD | 1995 | INST/ELEC WAREHOUSE-TSC | |
| Motor Pool | 94016 | 1 | 89520-POLL CATCH BAS | Paved parking @ 94010 | 1995 | USED ANTIFREEZE BAS-TSC | |
| Motor Pool | 94017 | 1 | 89520-POLL CATCH BAS | Pollutant catch basin @ 94010 | 1995 | USED OIL BASE- TSC | |
| Motor Pool | 94020 | 23936 | 44220- STORAGE GP INST | 439 OUTER FENCE RD | 1995 | TSC WAREHOUSE- TSC | |
| Motor Pool Storage | 94035 | 3526 | 44220- STORAGE GP INST | 439 OUTER FENCE RD | 2001 | INSTR INSTALL YARD-TSC | |
| Aprox.Total Square Footage of Real Property (RP) | 119270 |
238540
UIC:
WFH Footprint
91012-OEC HQ
TSC_Motor Pool
92003 OEC Resilency Building
Radio Hill
TURNED-IN
FTC
image1.png image2.png image3.svg Contract Facilities US Army Operational Test Command 94010 VEH MAINT Shop Bldg. Const. 1995. Approx. 16,500 Sq. Ft . 94020 Warehouse for Tests GFP Bldg. Const. 1995. Approx. 24,000 Sq. Ft. 94035 Instrumentation Install Yard Bldg. Const. 2001. Approx. 3,500 Sq. Ft. 94015 Instrumentation/Electronics Warehouse - Bldg. Const. 1995. Approx. 26,000 Sq. Ft. TSC - Contractor Operated Motor Pool Complex 92003 OTC Resiliency Bldg.
image4.png image5.svg US Army Operational Test Command Test Support/G6 Contractor – Radio Hill CA013 Test Teams Support 92074 A/B/C/D/E G6 Electronics Warehouse Shipping/Receiving Wing Legend A: G6 Contractors B: G6 Contractors C: TSD D: G6 Contractor Warehouse E: G6 warehouse & TTD Contractor Storage A B C D E image6.png image7.svg US Army Operational Test Command 53400 53405 Turned - in FTC 23 FTC 21 Turned - in Turned - in Turned - in Turned - in Turned - in FTC 14 FTC 13 Turned - in Turned - in FTC 10 FTC 09 FTC 08 FTC 07 FTC 06 FTC 05 FTC 04 FTC 03 Turned - In FTC 01 53404 53406 Forward Test Center (FTC) Test Test Divested Test Test Turned - in Turned - in Depicts FTC facilities Turned in Relocatable Photo and numbers inaccurat e
File details come from the government source that posted it. Updated .