This document is a Questions & Responses #3 addendum for the Alert GOV Parking Shelter solicitation (W50S9F-26-B-A011), posted to SAM.Gov on September 26, 2026. It clarifies three technical specifications related to asphalt paving work for the parking shelter project.
The responses confirm critical construction requirements: (1) the contractor must submit an asphalt mix design for approval that meets the specification criteria outlined in the solicitation; (2) a prime coat of cutback asphalt conforming to ASTM D2027/D2027M, Grade MC-30, is required over the gravel base, despite the specification section being blank; and (3) both coring tests to verify in-place density and straightedge testing for surface smoothness are mandatory quality assurance measures, notwithstanding these tests being atypical for standard projects. These clarifications address contractor concerns about ambiguous or incomplete specification language and establish definitive performance standards for the paving work.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Alert GOV Parking Shelter, Solicitation # W50S9F-26-B-A011 Posted to SAM.Gov 09 Sep 26
Questions & Responses #3
Question Response
1.
Please indicate what asphalt mix design should be used, the specs are not very descriptive
A mix design shall be submitted for review and approval by the awarded contractor that meets the various criteria outlined in the specifications.
2.
Please confirm if a prime coat on the gravel is required. The prime coat section in the specs (32 12 13, 2.1) is blank
Yes. Prime Coat shall be cutback asphalt conforming to ASTM D2027/D2027M, Grade MC-30.
3.
The spec includes coring testing and smoothness testing. This isn't common, can you confirm if it is required.
Yes, cores will be required to confirm in-place density and straightedge testing will be required for smoothness testing.