34-IT4.1.pdf

PDF 936 KB Posted

Attached to
PSXE222005 Repair Bldg 90100 for Blue Horizons
Solicitation number
W50S98-24-B-0004
Issued by

About this file

This document appears to be a technical drawing package for the "Repair Building 90100 for Blue Horizons 134th Air Refueling Wing" contract opportunity. The key details are:

The contract is for information technology (IT) and audiovisual (AV) infrastructure installation at the facility. The work includes installing a new IT rack, cable trays, outlet faceplates, and fiber optic and copper cabling. The drawings provide specifications for the IT and AV outlet configurations, cable routing, and labeling requirements. The related federal contract opportunity has a solicitation number of W50S98-24-B-0004 and is issued by the Department of the Army Tennessee Army National Guard. No specific response dates, award information, or set-asides are provided in this drawing package.

View the file

Other files

File Type Posted
OF_1419.pdf PDF
24B0004 Sign In Sheet.pdf PDF
BIA notes 28D.pdf PDF
24B0004 QA 2_Response_09.12.24.docx DOCX document
24B0004 QA_ Response_09.12.24.docx DOCX document
Wall image.jpg JPG image
INDEX_rev1_09.12.24.pdf PDF
08 44 13 Glazed Aluminum Curtain Walls.pdf PDF
35-IT4.2.pdf PDF
36-IT5.1.pdf PDF
W50S9824B0004.pdf PDF
00-COVER.pdf PDF
27.01.00 - Computer and Telephone Wiring.pdf PDF
24B0004 QA_ Response_09.03.24.docx DOCX document
33-IT2.1.pdf PDF
Blue Horizons_Hardware Specification.pdf PDF
W50S9824B0004P0002.pdf PDF
Blue Horizons_Hardware Sets.pdf PDF
Site-Visit Minutes 24B0004.pdf PDF
Pre-Bid Slides 24B0004.pptx PPTX presentation
Site Visit Sign In Sheet 24B0004.pdf PDF
W50S9824B0004P0001.pdf PDF
W50S9824B0004.pdf PDF
134th Repair Bldg 190 for Blue Horizons_Specifications_04.26.24.pdf PDF
W50S9824B0004.pdf PDF
134th Repair Building 90100 for Blue Horizons_Drawings_4-26-24.pdf PDF
Construction SOW PSXE222005 Repair Bldg 90100 for Blue Horizons rev1.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R ep ai r

B u ild in g fo r

B lu e H or iz on s

4t h A ir R ef u el in g W in g

PSXE222005

4.15.24

IT4.1

D E

TA

IL

S

I N

FO

R

M A

TI

O

N T

E C

H N

O

LO

G

IE

S

CWH

CJS

NEW RACK "03R1"

NO SCALE

A1

IT4.1

COMM LEGEND

TYPICAL COMM OUTLET DETAIL

NO SCALE

A13

IT4.1

TYP. CT FACEPLATE DETAIL

NO SCALE

H9

IT4.1

SECURE CT FACEPLATE DETAIL

NO SCALE

L9

IT4.1

TYP. AV FACEPLATE DETAIL

NO SCALE

H5

IT4.1

SECURE AV FACEPLATE DETAIL

NO SCALE

L5

IT4.1

DETAIL AT RATED WALL PENETRATION

NO SCALE

H1

IT4.1

(FRONT ELEVATION AT EQUIPMENT RACK) (FRONT ELEVATION AT EQUIPMENT RACK)

EXISTING RACK "02R1"

NO SCALE See Note #2 Sheet IT2.1

A1

IT4.1

01 A 1 F0 01

01 A 1 A 001

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

REVISIONS:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

PROJ. NO:

AutoCAD SHX Text

DRAWN:

AutoCAD SHX Text

CHECKED:

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

SHEET NO.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text N

AutoCAD SHX Text M

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text L

AutoCAD SHX Text K

AutoCAD SHX Text J

AutoCAD SHX Text H

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text C

AutoCAD SHX Text B

AutoCAD SHX Text A

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text G

AutoCAD SHX Text 240 West Bessemer St. Alcoa, TN. 37701

AutoCAD SHX Text

ph. 865 980 3500 fax. 865 980 3555

AutoCAD SHX Text H:\USPFO\47.201 - REPAIR BLDG 90100 FOR BLUE HORIZONS\02-DRAWINGS\SHEETS\IT\IT-REV.DWG PLOTTED PLOTTED ON:August 21, 2024 1:34 PM BY:CRAIG HANEYAugust 21, 2024 1:34 PM BY:CRAIG HANEY1:34 PM BY:CRAIG HANEYBY:CRAIG HANEYCRAIG HANEY

AutoCAD SHX Text McGhee Tyson ANGB, Tennessee

AutoCAD SHX Text McGhee Tyson ANGB, Tennessee

AutoCAD SHX Text

1. MOUNT 4"X4" JUCNTION BOXES AT SAME HEIGHT AS ELECTICAL

AutoCAD SHX Text

UNLESS NOTED OTHERWISE

AutoCAD SHX Text

2. OUTLET CONFIGURATION SHALL BE AS INDICATED ON PLANS

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

4"X4" DEEP SET

AutoCAD SHX Text

JUNCTION BOX

AutoCAD SHX Text

SINGLE GANG

AutoCAD SHX Text

EXTENSION

AutoCAD SHX Text

ROUTE ALL CABLE TO

AutoCAD SHX Text

CORRESPONDING PATCH

AutoCAD SHX Text

PANEL AS INDICATED.

AutoCAD SHX Text

1" EMT CONDUIT TO CABLETRAY ATTACH WITH

AutoCAD SHX Text

TERMINATE W/ BUSHING.

AutoCAD SHX Text

SELF GROUNDING CONDUIT CLAMP AND

AutoCAD SHX Text

DEVICE PLATE AND

AutoCAD SHX Text

OUTLETS, SEE DETAILS

AutoCAD SHX Text

THIS SHEET.

AutoCAD SHX Text

NEATLY BUNDLE CAT6 CABLES AND

AutoCAD SHX Text

SECURE TO CABLE RACK (PATHWAY)

AutoCAD SHX Text

EACH BUNDLE TO HAVE MAX 48 CABLES

AutoCAD SHX Text

AND SHOULD CORRESPOND TO A SINGLE

AutoCAD SHX Text

PATCH PANEL WHERE POSSIBLE.

AutoCAD SHX Text %%U"B"

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text ELECTRICAL PANEL "B" INDICATES PANEL DESIGNATION. SHOWN FOR REFERENCE ONLY. REFER TO ELECTRICAL PLANS FOR EXACT LOCATIONS. DO NOT RUN COMM WIRING OR CONDUIT THRU REQUIRED CLEAR SPACE ABOVE AND IN FRONT OF PANELBOARD.

AutoCAD SHX Text "CTS" COMMUNICATIONS TERMINAL SPACE. 3/4" VOID FREE SANDED A/C PLYWOOD. PAINT WITH TWO COATS OF WHITE FIRE RETARDANT PAINT. SECURELY FASTENED TO WALL STRUCTURE. SIZE AS INDICATED.

AutoCAD SHX Text

%%U"CTS"

AutoCAD SHX Text

%%U"BEP"

AutoCAD SHX Text "BEP" BUILDING ENTRANCE PROTECTION MOUNT ON WALL AS DIRECTED AND CONNECT TO GROUND BUS. SEE SPECIFICATIONS FOR MORE INFORMATION.

AutoCAD SHX Text

AV

AutoCAD SHX Text

INFORMATION OUTLET, SEE DETAIL H9 FOR MORE INFORMATION.

AutoCAD SHX Text

CT

AutoCAD SHX Text EXISTING 12" / 18" BASKET TRAY BELOW ACCESSIBLE FLOOR, SEE PLANS FOR CABLE TYPE. PROVIDE SEPARATION OF CABLE TYPES. PROVIDE "J" HOOKS AND SLEEVES AS REQUIRED TO NEATLY ROUTE CABLE TO DESTINATION. BUNDLE CABLES NEATLY WITH VELCRO FASTENERS EVERY 4'.

AutoCAD SHX Text CONDUIT ROUTED UNDER FLOOR. TURN UP CONCEALED IN WALLS AND STUB-OUT ABOVE CEILING UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text CABLE TRAY 12" MIN. OR AS INDICATED ON DRAWINGS. HOME RUN TO COMM ROOM. SEE FLOOR PLANS FOR ROUTING. ONLY SCS CABLING ALLOWED INSIDE TRAY AND NO OTHER SYSTEM WIRING ALLOWED TO ATTACH TO TRAY.

AutoCAD SHX Text CONDUIT ABOVE CEILING OR IN WALLS. ROUTE ALL CONDUIT CONCEALED IN WALLS, FLOORS OR ABOVE CEILING UNLESS OTHERWISE INDICATED.

AutoCAD SHX Text

TYPICAL WORK AREA OUTLET ON EACH 8P8C (RJ-45) CENTER KEYED JACK

AutoCAD SHX Text

TERMINATE ALL CONDUCTORS OF ALL FOUR CAT-6A UTP CABLES TO PATCH

AutoCAD SHX Text

PANEL PER PROJECT PLAN

AutoCAD SHX Text

TYPICAL NOTE:

AutoCAD SHX Text

VIA EXTERNAL

AutoCAD SHX Text

AND INTERNAL

AutoCAD SHX Text

LABELS AND (TYP)

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (GREEN)

AutoCAD SHX Text

CONNECTORS #1 & #3

AutoCAD SHX Text

FACEPLATE PER

AutoCAD SHX Text

SPECIFICATIONS

AutoCAD SHX Text

CT

AutoCAD SHX Text

SYMBOL:

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (GREEN)

AutoCAD SHX Text

CONNECTOR #2

AutoCAD SHX Text

IDENTIFICATION

AutoCAD SHX Text STRUCTURED AV OUTLET, SEE DETAIL H5 FOR MORE INFORMATION. TWO OUTLETS INDICATED BY ONE SYMBOL. INTERCONNECT YELLOW ETHERNET OUTLETS WITH 500 MHZ SHIELDED CAT SIX CABLE, AND HDMI OUTLETS WITH 4K HDMI CABLE RATED FOR IN WALL INSTALLATION.

AutoCAD SHX Text

LC OM3 MULTIMODE KEYSTONE

AutoCAD SHX Text

CONNECTOR #4

AutoCAD SHX Text

TYPICAL WORK AREA OUTLET ON EACH 8P8C (RJ-45) CENTER KEYED JACK

AutoCAD SHX Text

TERMINATE ALL CONDUCTORS OF ALL FOUR CAT-6A UTP CABLES TO PATCH

AutoCAD SHX Text

PANEL PER PROJECT PLAN

AutoCAD SHX Text

TYPICAL NOTE:

AutoCAD SHX Text

RED FACEPLATE PER

AutoCAD SHX Text

SPECIFICATIONS

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

CONNECTOR #2

AutoCAD SHX Text

LC OM3 MULTIMODE KEYSTONE

AutoCAD SHX Text

CONNECTOR #4 (UNKEYED)

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (RED)

AutoCAD SHX Text

CONNECTOR #1

AutoCAD SHX Text

LC OM3 MULTIMODE KEYSTONE

AutoCAD SHX Text

CONNECTOR #3 (UNKEYED)

AutoCAD SHX Text

IDENTIFICATION VIA EXTERNAL AND INTERNAL LABELS AND (TYP)

AutoCAD SHX Text

CT

AutoCAD SHX Text

SYMBOL:

AutoCAD SHX Text

(8P8C) (RJ-45) (RED)

AutoCAD SHX Text

VIA EXTERNAL

AutoCAD SHX Text

AND INTERNAL

AutoCAD SHX Text

LABELS AND (TYP)

AutoCAD SHX Text

CONNECTORS #1

AutoCAD SHX Text

FACEPLATE PER

AutoCAD SHX Text

SPECIFICATIONS

AutoCAD SHX Text

AV

AutoCAD SHX Text

SYMBOL:

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (YELLOW)

AutoCAD SHX Text

CONNECTOR #2

AutoCAD SHX Text

IDENTIFICATION

AutoCAD SHX Text

LC OM3 MULTIMODE KEYSTONE

AutoCAD SHX Text

CONNECTOR #4

AutoCAD SHX Text

IDENTIFICATION

AutoCAD SHX Text

AV

AutoCAD SHX Text

SYMBOL:

AutoCAD SHX Text

MOUNT 18" AFF

AutoCAD SHX Text

MOUNT 18" AFF

AutoCAD SHX Text

UL SYSTEM #202

AutoCAD SHX Text

METAL PIPE/CONDUIT

AutoCAD SHX Text

THE WALL.

AutoCAD SHX Text

BOTH SURFACES OF

AutoCAD SHX Text

INSTALLED FLUSH TO

AutoCAD SHX Text

3 M FIRE BARRIER

AutoCAD SHX Text

MOLDABLE PUTTY

AutoCAD SHX Text

MINIMUM

AutoCAD SHX Text

PUTTY THICKNESS

AutoCAD SHX Text 1/2" (13mm)

AutoCAD SHX Text 1" (25mm)

AutoCAD SHX Text

A) MAXIMUM ANNULAR SPACE BETWEET PIPE AND OPENING NOT TO EXCEED 3/4 INCH.

AutoCAD SHX Text %%uNOTES:

AutoCAD SHX Text

MAXIMUM

AutoCAD SHX Text

PIPE SIZES

AutoCAD SHX Text 5" (127mm)

AutoCAD SHX Text 10" (254mm)

AutoCAD SHX Text

OPENING SIZE

AutoCAD SHX Text

MAXIMUM

AutoCAD SHX Text 6 1/4" (159mm)

AutoCAD SHX Text 12 1/4" (311mm)

AutoCAD SHX Text %%uSIDE VIEW

AutoCAD SHX Text

TABLES BELOW

AutoCAD SHX Text

OPENING SIZE SEE

AutoCAD SHX Text

RATING

AutoCAD SHX Text

2 HOUR

AutoCAD SHX Text

3 HOUR

AutoCAD SHX Text "F"

AutoCAD SHX Text %%uCROSS-SECTION VIEW

AutoCAD SHX Text

FIRE RATED CONCRETE OR CONCRETE BLOCK WALL

AutoCAD SHX Text

AV

AutoCAD SHX Text

SECURE INFORMATION OUTLET, SEE DETAIL L9 FOR MORE INFORMATION.

AutoCAD SHX Text

CT

AutoCAD SHX Text NEW 12" ALUMINUM LADDER TYPE CABLE TRAY 10'-6" ABOVE FINISHED CEILING, SEE PLANS FOR CABLE TYPE. PROVIDE SEPARATION OF CABLE TYPES. PROVIDE "J" HOOKS AND SLEEVES AS REQUIRED TO NEATLY ROUTE CABLE TO DESTINATION. BUNDLE CABLES NEATLY WITH VELCRO FASTENERS EVERY 4'.

AutoCAD SHX Text

%%UNOTE:

AutoCAD SHX Text

SEE DETAIL H1 SHEET IT4.1 FOR CONNECTION TO UNDER FLOOR BASKET TYPE CABLE TRAY.

AutoCAD SHX Text

IN COMM. CONTRACT

AutoCAD SHX Text

RACK SPACE FOR USE

AutoCAD SHX Text

BY GOVERNMENT

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

CABLE MANAGER WMPH2E

AutoCAD SHX Text

(TYPICAL)

AutoCAD SHX Text VERTICAL CABLE MANAGERS, AND POWER DISTRIBUTION UNITS PROVIDED AND INSTALLED IN THIS CONTRACT.

AutoCAD SHX Text

12 MODULE FIBER SHELF PANEL "03RF1"

AutoCAD SHX Text

48 PORT PATCH

AutoCAD SHX Text

PANEL "C" NOTE #1

AutoCAD SHX Text

48 PORT PATCH

AutoCAD SHX Text

PANEL "A" NOTE #1

AutoCAD SHX Text

48 PORT PATCH

AutoCAD SHX Text

PANEL "B" NOTE #1

AutoCAD SHX Text

48 PORT PATCH

AutoCAD SHX Text

PANEL "D" NOTE #1

AutoCAD SHX Text RACK NOTES: 1. 48 PORT PATCH PANEL SEE SPECS. 48 PORT PATCH PANEL SEE SPECS. 2U PATCH PANEL.

AutoCAD SHX Text

48 PORT PATCH

AutoCAD SHX Text

PANEL "E" NOTE #1

AutoCAD SHX Text 6 MODULE FIBER SHELF PANEL "03RF2" EXTEND 24 STRAND OM3 FEEDER TO COMM ROOM "A" AND TERMINATE AS DIRECTED.

AutoCAD SHX Text

IN COMM. CONTRACT

AutoCAD SHX Text

RACK SPACE FOR USE

AutoCAD SHX Text

BY GOVERNMENT

AutoCAD SHX Text

FLOOR

AutoCAD SHX Text

CABLE MANAGER WMPH2E

AutoCAD SHX Text

(TYPICAL)

AutoCAD SHX Text VERTICAL CABLE MANAGERS, AND POWER DISTRIBUTION UNITS PROVIDED AND INSTALLED IN THIS CONTRACT.

AutoCAD SHX Text

NEW 12 MODULE FIBER SHELF PANEL "02RF1"

AutoCAD SHX Text

NEW 48 PORT PATCH

AutoCAD SHX Text

PANEL "A" NOTE #1

AutoCAD SHX Text RACK NOTES: 1. 48 PORT PATCH PANEL SEE SPECS. 48 PORT PATCH PANEL SEE SPECS. 2U PATCH PANEL.

AutoCAD SHX Text INFORMATION OUTLET IN SYSTEMS FURNITURE, PROVIDE FLEXIBLE WHIP CONNECTION TO FURNITURE RACEWAY ROUTE CABLES THEREIN AND INSTALL INFORMATION OUTLET IN FURNITURE.

AutoCAD SHX Text

FC

AutoCAD SHX Text

FC

AutoCAD SHX Text SECURE INFORMATION OUTLET IN SYSTEMS FURNITURE, PROVIDE FLEXIBLE WHIP CONNECTION TO FURNITURE RACEWAY ROUTE CABLES THEREIN AND INSTALL SECURE INFORMATION OUTLET IN FURNITURE.

AutoCAD SHX Text

(EXAMPLE)

AutoCAD SHX Text

FLOOR NUMBER

AutoCAD SHX Text

CLOSET DESIGNATION

AutoCAD SHX Text

RACK DESIGNATION

AutoCAD SHX Text

FIBER CABLE LABELING NOTE:

AutoCAD SHX Text

CAT6 CABLE LABELING NOTE:

AutoCAD SHX Text

(EXAMPLE)

AutoCAD SHX Text

PORT NUMBER IN PATCH PANEL (CABLE)

AutoCAD SHX Text

PATCH PANEL DESIGNATION

AutoCAD SHX Text

FLOOR NUMBER

AutoCAD SHX Text

CLOSET DESIGNATION

AutoCAD SHX Text

RACK DESIGNATION

AutoCAD SHX Text

PORT NUMBER IN PATCH PANEL (CABLE)

AutoCAD SHX Text

FIBER PATCH PANEL DESIGNATION

AutoCAD SHX Text

(TO JACK ABOVE/BELOW)

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (BLUE)

AutoCAD SHX Text

CONNECTORS #3

AutoCAD SHX Text

HDMI

AutoCAD SHX Text

VANCO #820490 HDMI KEYSTONE JACK WITH F-F PIGTAIL. TO TV2 TO TV1

AutoCAD SHX Text

NOTE: ONE SYMBOL INDICATES TWO INTERCONNECTED OUTLETS MOUNT 18"/80" AFF

AutoCAD SHX Text

VIA EXTERNAL

AutoCAD SHX Text

AND INTERNAL

AutoCAD SHX Text

LABELS AND (TYP)

AutoCAD SHX Text

CONNECTORS #1

AutoCAD SHX Text

FACEPLATE PER

AutoCAD SHX Text

SPECIFICATIONS

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (YELLOW)

AutoCAD SHX Text

CONNECTOR #2

AutoCAD SHX Text

IDENTIFICATION

AutoCAD SHX Text

LC OM3 MULTIMODE KEYSTONE

AutoCAD SHX Text

CONNECTOR #4

AutoCAD SHX Text

IDENTIFICATION

AutoCAD SHX Text

(TO JACK ABOVE/BELOW)

AutoCAD SHX Text

8-PIN 8-CONDUCTOR

AutoCAD SHX Text

(8P8C) (RJ-45) (RED)

AutoCAD SHX Text

CONNECTORS #3

AutoCAD SHX Text

HDMI

AutoCAD SHX Text

VANCO #820490 HDMI KEYSTONE JACK WITH F-F PIGTAIL. TO TV2 TO TV1

AutoCAD SHX Text

NOTE: ONE SYMBOL INDICATES TWO INTERCONNECTED OUTLETS MOUNT 18"/80" AFF

AutoCAD SHX Text SECURE STRUCTURED AV OUTLET, SEE DETAIL L5 FOR MORE INFORMATION. TWO OUTLETS INDICATED BY ONE SYMBOL. INTERCONNECT YELLOW ETHERNET OUTLETS WITH 500 MHZ SHIELDED CAT SIX CABLE, AND HDMI OUTLETS WITH 4K HDMI CABLE RATED FOR IN WALL INSTALLATION.

AutoCAD SHX Text 6 MODULE FIBER SHELF PANEL "02RF2" TETMINATE CABLE FROM "03RF2" HERE AS DIRECTED.

Sheets and Views
IT4.1

File details come from the government source that posted it. Updated .