Demolition Plan - 101.pdf
PDF 927 KB Posted
- Attached to
- Construct Wall Bldg . 150 and 101 Federal contract opportunity
- Solicitation number
- W50S8S23B0001
- Issued by
- Department of the Army National Guard
About this file
This demolition plan outlines work to be performed at Building 101 in preparation for the Construct Wall Bldg . 150 and 101 solicitation. The plan calls for removing an existing wall to the bottom of the second floor, repairing an existing ceiling, soffit and wall, removing a minimum of 16 feet of hoist rail just below the ceiling, and removing a compressed air outlet and associated piping to a point above the ceiling, capping the unused end.
The related solicitation, number W50S8S23B0001, is for construction work at Building 101 and Building 150 issued by the Department of the Army National Guard. The solicitation seeks offers to construct walls at the two buildings following demolition in accordance with the plan. Responses are due based on the specified solicitation number.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| W50S8S23B0001 Construct Walls.pdf | ||
| W50S8S23B0001 00001 Conform.pdf | ||
| Attendance Site Visit Agenda.pdf | ||
| Floor plan - Bldg. 101.pdf | ||
| Electrical Demolition Plan - 101.pdf | ||
| W50S8S23B0001 0001 Amendment.pdf | ||
| PWSWYTD232003.docx | DOCX document | |
| Reflected ceiling plan - 101.pdf | ||
| Lighting plan - 101.pdf | ||
| Electrical Plan - Bldg. 101.pdf | ||
| Bldg-150 Partial Floor Plan.pdf | ||
| PWS WYTD232003 Const walls 150 Rev 1.docx | DOCX document | |
| Existing lighting plan - 150.pdf | ||
| W50S8S23B0001 Construct Wall.pdf |
Show all 14
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1075445152E Text Box Demoliton Plan - 101 No scale
1075445152E Callout Remove existing wall to bottom of 2nd floor above. Repair existing ceiling, soffit and wall.
1075445152E Callout Remove a minimum of 16' +/- of the existing hoist rail which is mounted just below the ceiling and supported by the structure above the ceiling. There is a picture of a typical piece of the rail on the Electrical Demolition Plan.
1075445152E Polygon
1075445152E Callout Remove compressed air outlet, and associated piping to a point above the ceiling. Cap unused end and make air tight.