About this file
This document appears to be a floor plan drawing (A-101) for a security upgrade project (WST Security Upgrades) at the 121st Air Refueling Wing of the Rickenbacker Air National Guard Base in Columbus, Ohio. The project involves upgrading the security arrangement for the Aircrew Training System (ATS) Facility to allow for a secure training interface. Key requirements include:
Upgrading the existing door and frame to accommodate Advantor access controls, constructing a separate classified briefing area in the Maintenance/Parts Storage Area, adding HVAC, fire strobe, and 120VAC power for the MAF DMO equipment in the Computer Room. The project has an anticipated construction duration of 120 calendar days. This is a competitive Small Business Set-aside with a NAICS code of 236220 and a size standard of $45 million average annual revenue. The magnitude of the project is between $25,000 and $100,000. The solicitation and associated information will only be available through the SAM.gov website.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Absract of Offers - OF_1419.pdf | ||
| ATTACHMENT 1 SOW for NLZG242009 WST Security Upgrades REV1 4_16_24.docx | DOCX document | |
| Site Walk Sign-In 9-Apr-2024.pdf | ||
| Pre-Award RFIs 24-2009 WST.docx | DOCX document | |
| W50S8P24B00020001_Amend.pdf | ||
| ATTACHMENT 1 SOW for NLZG242009 WST Security Upgrades.docx | DOCX document | |
| ATTACHMENT 2.1 WST 1 A-101.pdf | ||
| ATTACHMENT 2.3 WST 1 M-102.pdf | ||
| ATTACHMENT 3 RFI.docx | DOCX document | |
| ATTACHMENT 4 SFS Form 3_EAL Request.pdf | ||
| W50S8P24B0002.pdf | ||
| ATTACHMENT 2.2 WST 1 M-101.pdf |
Show all 12
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
INSTRUCTORS
DEBRIEF B
DEBRIEF A
SIM BAY
COMM
BREAK AREA
CORRIDOR
SITE MANAGER
TOILET
MAINT / PARTS STORAGE
COMPUTER ROOM
HPU ROOM
VESTIBULE
BRIEF / DEBRIEF
181B
UPS
1,3,5
12' - 7"
A
FINISH CEILING
WHERE OCCURS @
9'-0"
MTL. STUD
FRAMING @ 1'-4"
O.C.
RUNNER TRACK
(1) LAYER 5/8"
GWB (EACH SIDE)
6" MTL. STUD PARTITION
BRACING
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
I T
T E
D
B
Y
C H
E C
K E
D
B
Y
D R
A W
N
B
Y
D E
S I G
N E
D
B
Y
C O
N T
R A
C T
N
O
S O
L I C
I T
A T
I O
N
N
O
I S
S U
E
D
A T
E
S I Z
E
M A
R K
D E
S C
R I P
T I O
N D
A T
E
SHEET ID
S
T
C
I V
I L
E
N G
I N
E E
R
S
Q U
A D
R O
N
S
T
A
I R
E F
U E
L I N
G
W
I N
G
R I C
K E
N B
A C
K E
R
A
A T
I O
N A
L
G
U A
D
B
S
E
M
I N
U T
E M
W
Y
C
L U
M B
U S
O
H
X X
X
X X
X X
X
A N
S I
D
R I C
K E
N B
A C
K E
R
A
T
I O
N A
L
G
U A
D
B
S
E
O
H I O
N L Z
G
W
T S
S
E C
U R
I T
Y
U
P G
R A
D E
S
B U
I L D
I N
G
M
H
I S
S O
M
S
P
R I C
E
M
H
I S
S O
M
S
P
R I C
E
F L O
P
L A
N
M
U L T
I D
I S
C I P
L I N
E
A-101
A
T
I O
N A
L
G
U A
R D
SCALE: 3/16" = 1'-0 '
MULTIDISCIPLINE FLOOR PLAN
D1
PLAN
NORTH
1. VERIFY EXISTING CONDITIONS. COORDINATE THE EXTENT OF DEMOLITION
WORK AND EXISTING WORK TO REMAIN, WITH NEW WORK.
2. EXISTING FLOOR PLANS ARE BASED ON COPIES OF ARCHIVE DRAWINGS
PROVIDED BY THE GOVERNMENT. ACTUAL EXISTING WALL LOCATION/
ASSEMBLY MAY VARY. REPORT DISCREPANCIES, CONFLICTS OR
UNEXPECTED CONDITIONS TO THE CONTRACTING OFFICER.
3. REPAIR / PATCH NEW OPENINGS IN WALLS, PARTITIONS, FLOORS AND
CEILINGS WHERE DEMOLITION OCCURS. MATCH EXISTING ADJACENT
SURFACE FINISHES.
4. IN-SERVICE EQUIPMENT SHALL BE PROTECTED FROM CONSTRUCTION
ACTIVITIES AT ALL TIMES.
5. MAINTAIN AN UNOBSTRUCTED EXIT PATH TO THE PRIMARY EXITS FOR THE
DURATION OF CONSTRUCTION.
6. NEW BRIEF / DEBRIEF ROOM DIMENSION ARE SET TO APPROXIMATELY 12' - 7"
X 12' ON THE INTERIOR, AT APPROXIMATELY 151.5 SQFT.
7. ALL FINISH CEILINGS AT 9'-0" ABOVE FINISH FLOOR UNLESS NOTED
OTHERWISE.
8. 2'X2' SUSPENDED ACOUSTICAL CEILING - CENTER GRID IN ROOM OR SPACE
UNLESS OTHERWISE INDICATED.
9. WORK AREA SHALL BE KEPT CLEAN OF DEBRIS AND DUST AT THE END OF
EACH WORK DAY.
GENERAL ARCHITECTUAL NOTES
ARCHITECTURAL KEYNOTES
1. REMOVE AND REPLACE INTERIOR DOOR AND FRAME, INSTALLATION OF NEW
METAL HOLLOW DOOR AND FRAME SHALL BE A MODEL AND TYPE
COMPATIBLE WITH ADVANTOR EQUIPMENT.
2. ADD 120V SINGLE PHASE 20AMP FEED, POWER FEED FROM UPS PANEL 1,3,5
THROUGH RAISED FLOOR TO IN FLOOR OUTLET AS SHOWN IN ROOM 182.
CONTRACTOR TO FIELD VERIFY OUTLET CONDUIT ROUTING AND LOCATION
WITH CUSTOMER.
3. ADD A NEW 24" X 12" RETURN DUCT, AREA TO BE FIELD VERIFIED. TIE INTO
EXISTING RETURN LINE.
4. ADD NEW FIRE STROBE, CEILING MOUNTED. POWER FEED TO EXISTING
CONTROL PANEL.
5. RELOCATE EXISTING AIR DEVICE 24" X 24" SUPPLY DUCT TO NEW LOCATION,
AREA TO BE FIELD VERIFIED.
6. ADD SINGLE DOOR AND FRAME OPENING MATCHING EXISTING STUD
INTERVALS, INSTALL
GDW ON BOTH SIDES, MATCH OVERHEAD SHEETING
LINE.
0 2' 4'1'