ATTACHMENT 2.1 WST 1 A-101.pdf

PDF 147 KB Posted

Attached to
WST Security Upgrades Federal contract opportunity
Solicitation number
W50S8P24B0002
Issued by
Department of the Army National Guard

About this file

This document appears to be a set of architectural floor plans for a security upgrade project at the Rickenbacker Air National Guard Base in Columbus, Ohio. The project, titled "WST Security Upgrades Building 888", includes the following key details:

The 121st Air Refueling Wing is integrating the KC-135R Aircrew Training System (ATS) into the Distributed Training Center Network, which requires upgrading the security arrangement for the ATS Facility. Specific upgrades include: installing a controlled access door and frame to accommodate Advantor controls, constructing a separate classified briefing area in the Maintenance/Parts Storage Area, adding HVAC supply and return, and a new fire strobe. The project also includes installing the MAF DMO Equipment in the Computer Room and providing a dedicated 20-amp 120VAC power circuit. Ductwork larger than 96 sq. in. will have grille systems installed to prevent intrusion. The anticipated construction/contract duration is 120 calendar days. This project will be solicited as a competitive Small Business Set-aside with a NAICS code of 236220 and a size standard of $45 million average annual revenue. The magnitude of the project is between $25,000 and $100,000.

View the file

Other files for this federal contract opportunity

Other files attached to WST Security Upgrades, newest first.
File Type Posted
Absract of Offers - OF_1419.pdf PDF
ATTACHMENT 1 SOW for NLZG242009 WST Security Upgrades REV1 4_16_24.docx DOCX document
ATTACHMENT 2.1 WST 1 A-101 REV1 4_10_24.pdf PDF
Site Walk Sign-In 9-Apr-2024.pdf PDF
Pre-Award RFIs 24-2009 WST.docx DOCX document
W50S8P24B00020001_Amend.pdf PDF
ATTACHMENT 1 SOW for NLZG242009 WST Security Upgrades.docx DOCX document
ATTACHMENT 2.3 WST 1 M-102.pdf PDF
ATTACHMENT 3 RFI.docx DOCX document
ATTACHMENT 4 SFS Form 3_EAL Request.pdf PDF
W50S8P24B0002.pdf PDF
ATTACHMENT 2.2 WST 1 M-101.pdf PDF
Show all 12

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTRUCTORS

DEBRIEF B

DEBRIEF A

SIM BAY

COMM

BREAK AREA

CORRIDOR

SITE MANAGER

TOILET

MAINT / PARTS STORAGE

COMPUTER ROOM

HPU ROOM

VESTIBULE

BRIEF / DEBRIEF

181B

UPS

1,3,5

A

FINISH CEILING

WHERE OCCURS

MTL. STUD

FRAMING @ 1'-4"

O.C.

RUNNER TRACK

(1) LAYER 5/8"

GWB (EACH SIDE)

6" MTL. STUD PARTITION

BRACING

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20

A

B

C

D

E

F

G

H

J

K

L

M

N

P

S U

B M

I T

T E

D

B

Y

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

D E

S I G

N E

D

B

Y

C O

N T

R A

C T

N

O

S O

L I C

I T

A T

I O

N

N

O

I S

S U

E

D

A T

E

S I Z

E

M A

R K

D E

S C

R I P

T I O

N D

A T

E

SHEET ID

S

T

C

I V

I L

E

N G

I N

E E

R

S

Q U

A D

R O

N

S

T

A

I R

E F

U E

L I N

G

W

I N

G

R I C

K E

N B

A C

K E

R

A

A T

I O

N A

L

G

U A

D

B

S

E

M

I N

U T

E M

W

Y

C

L U

M B

U S

O

H

X X

X

X X

X X

X

A N

S I

D

R I C

K E

N B

A C

K E

R

A

T

I O

N A

L

G

U A

D

B

S

E

O

H I O

N L Z

G

W

T S

S

E C

U R

I T

Y

U

P G

R A

D E

S

B U

I L D

I N

G

M

H

I S

S O

M

S

P

R I C

E

M

H

I S

S O

M

S

P

R I C

E

F L O

P

L A

N

M

U L T

I D

I S

C I P

L I N

E

A-101

A

T

I O

N A

L

G

U A

R D

SCALE: 3/16" = 1'-0 '

MULTIDISCIPLINE FLOOR PLAN

D1

PLAN

NORTH

1. VERIFY EXISTING CONDITIONS. COORDINATE THE EXTENT OF DEMOLITION

WORK AND EXISTING WORK TO REMAIN, WITH NEW WORK.

2. EXISTING FLOOR PLANS ARE BASED ON COPIES OF ARCHIVE DRAWINGS

PROVIDED BY THE GOVERNMENT. ACTUAL EXISTING WALL LOCATION/

ASSEMBLY MAY VARY. REPORT DISCREPANCIES, CONFLICTS OR

UNEXPECTED CONDITIONS TO THE CONTRACTING OFFICER.

3. REPAIR / PATCH NEW OPENINGS IN WALLS, PARTITIONS, FLOORS AND

CEILINGS WHERE DEMOLITION OCCURS. MATCH EXISTING ADJACENT

SURFACE FINISHES.

4. IN-SERVICE EQUIPMENT SHALL BE PROTECTED FROM CONSTRUCTION

ACTIVITIES AT ALL TIMES.

5. MAINTAIN AN UNOBSTRUCTED EXIT PATH TO THE PRIMARY EXITS FOR THE

DURATION OF CONSTRUCTION.

6. WORK AREA SHALL BE KEPT CLEAN OF DEBRIS AND DUST AT THE END OF

EACH WORK DAY.

GENERAL ARCHITECTUAL NOTES

ARCHITECTURAL KEYNOTES

1. REMOVE AND REPLACE INTERIOR DOOR AND FRAME, INSTALLATION OF NEW

METAL HOLLOW DOOR AND FRAME SHALL BE A MODEL AND TYPE

COMPATIBLE WITH ADVANTOR EQUIPMENT.

2. ADD 120V SINGLE PHASE 20AMP FEED, POWER FEED FROM UPS PANEL 1,3,5

THROUGH RAISED FLOOR TO IN FLOOR OUTLET AS SHOWN IN ROOM 182.

CONTRACTOR TO FIELD VERIFY OUTLET CONDUIT ROUTING AND LOCATION

WITH CUSTOMER.

3. ADD A NEW 24" X 12" RETURN DUCT, AREA TO BE FIELD VERIFIED. TIE INTO

EXISTING RETURN LINE.

4. ADD NEW FIRE STROBE, CEILING MOUNTED. POWER FEED TO EXISTING

CONTROL PANEL.

5. RELOCATE EXISTING AIR DEVICE 24" X 24" SUPPLY DUCT TO NEW LOCATION,

AREA TO BE FIELD VERIFIED.

6. ADD SINGLE DOOR AND FRAME OPENING MATCHING EXISTING STUD

INTERVALS, INSTALL

GDW ON BOTH SIDES, MATCH OVERHEAD SHEETING

LINE.

0 2' 4'1'

Sheets and Views
A-101

File details come from the government source that posted it. Updated .