Solicitation Q A.docx

DOCX document 17 KB Posted

Attached to
Local Telecommunication Service (LTS) and Long Distance Services (LDS)
Solicitation number
W50S8025QA012
Issued by

About this file

This document is a Questions and Answers (Q&A) file for Solicitation W50S8025QA012, relating to Local Telecommunication Service (LTS) and Long Distance Services (LDS) for the Massachusetts Air National Guard 102nd Intelligence Wing. The Q&A provides critical clarifications about the telecommunication service requirements, including specific details about equipment and installation. Key clarifications include confirming the installation address as 104 James A. Giammalvo Rd in Buzzards Bay, MA, adjusting the project start date to 30 days after award, and specifying the current telecommunications infrastructure as 2 SIP trunks converted to 4 PRIs through Adtran flex routers and Adtrans. The solicitation is structured as a Full and Open Competition using Simplified Acquisition Procedures, targeting small businesses under NAICS Code 517111 with a size standard of 1,500 employees, and intends to issue a single Firm Fixed Price purchase order with a performance start date no later than April 1st, 2025.

View the file

Other files

File Type Posted
SolicitationQA_R2_2025.03.20.docx DOCX document
Solicitation QA_R2_2025.03.20.docx DOCX document
Solicitation Q A_R1.docx DOCX document
Solicitation - W50S8025QA012.pdf PDF
PWS_Otis ANG LTS.v1.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W50S8025QA012 Q & A

Q1. In the PWS, 5.1 you list the switch is install at Grate Falls Montana. Can you please provide the correct address?

A1. 104 James A. Giammalvo Rd, Buzzards Bay, MA 02542

Q2. In the PWS, 4.3.1 you have the acceptable time frame to complete the cutover is 30-days, but 1.3 period of performance listed the start date at 1-April-2025. Can the start date be adjusted to be 30-days after award?

A2. Yes.

Q3. In the PWS, 1.1 you state that the current service is SIP with and emulated TDM handoff. Is this a T1 or PRI circuit? How many T1 or PRI circuits are required? If this is for SIP trunks, how many call paths are you requesting?

A3. We have 2 SIP trunks that run through flex routers and into Adtrans that convert to 4 PRIs

Q4. In the Solicitation CLIN 0001 you have listed an Adtran 908. Is this the device that you are currently using to take the SIP dial tone and emulating the T1/PRI circuits with?

A4. Yes

Q5. The Adtran 908 can deliver 8-analog POTs lines, are you using any analog POTs lines, if so how many?

A5. We are using POTS but our Phone switch provides the Analog tone/connection.

Q6. What is the address of the demarcation location?

A6. 104 James A. Giammalvo Rd Buzzards Bay MA 02542