AE-601.pdf
PDF 167 KB Posted
- Attached to
- 183 CES Repair CRF Building P-17
- Solicitation number
- W50S7U-21-B-0001
- Issued by
-
Department of the Army National Guard
About this file
This solicitation package includes plans and specifications for repair work to Building P-17 at the 183rd Communications Squadron facility. The work includes repairs to the building envelope, doors, windows and interior finishes. The solicitation is issued by the Department of the Army National Guard under contract number W50S7U-21-B-0001. Bids are due by the date identified in the solicitation package. The successful bidder will be awarded a contract to complete the repair work in accordance with the project manual, drawings, specifications and statement of work provided. Site visits are available for bidders to inspect the building and project scope.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
D O
O R
H
EI
G H
T
DOOR WIDTH
D O
O R
H
EI
G H
T
DOOR WIDTH
SFX STEEL, EXTERIOR
SFI STEEL, INTERIOR
SLI STEEL, INTERIOR
REF DOOR
SCHEDULE
FOR SIZE
D O
O R
H
EI
G H
T
DOOR WIDTH
GLAZING
REF DOOR
SCHEDULE
FOR TYPE
SGX STEEL, EXTERIOR
D O
O R
H
EI
G H
T
DOOR WIDTH
RDX ROLLING DOOR, EXTERIOR
S2 STEEL
D O
O R
H
EI
G H
T 2"
2" 2" 2" 2"DOOR WIDTH DOOR WIDTH
D2 STEEL
D O
O R
H
EI
G H
T 2"
TYPE NOTES
HEAD
JAMB
SILL
W1
TRANSLUCENT
WALL PANEL
6'-0"
6' -0
3'
-0
GROUND FLOOR
EL 100'-0"
TYPE NOTES
HEAD
JAMB
SILL
W2
TRANSLUCENT
WALL PANEL
6'-0"
6' -0
3'
-0
GROUND FLOOR
EL 100'-0"
TRANSLUCENT
WALL PANEL
TYPE NOTES
HEAD
JAMB
SILL
W3
6'-0"
2' -0
7'
-0
GROUND FLOOR
EL 100'-0"
TYPE NOTES
HEAD
JAMB
SILL
W4
8'-0"
6" 4'
-0
EL 130'-6"
HIGH ROOF
TRANSLUCENT
WALL PANEL
TYPE NOTES
HEAD
JAMB
SILL
W5
EL 100'-0"
GROUND FLOOR
3' -2
4'
-0
'-0
4'-1 5/8"
TYPE NOTES
HEAD
JAMB
SILL
W6
EL 100'-0"
GROUND FLOOR
7' -2
'-0
4'-1 5/8"
TYPE NOTES
HEAD
JAMB
SILL
W7
EL 100'-0"
GROUND FLOOR
'-0
9'
-2
4'-4"
FINISH ABBREV LEGEND
ACOUSTICAL CEILING TILE
SEALED CONCRETE FLOOR
EXPOSED
PAINT
CERAMIC TILE BASE
CARPET TILE
RUBBER BASE
ACT
CONC
EXP
PT
CB
CPT
RB
EPOXY FLOOR COATINGEF
INTEGRAL COVE BASEICB
LINER PANELLP
TRANSITION STRIPTS
GYPSUM BOARD CEILINGGYP BD
CERAMIC FLOOR TILECFT
CERAMIC WALL TILECWT
LA
YO
U T
DR
AW
N
RE
VI
EW
ED
D0 sheetsof XX
R
EV
IS
IO
N D
AT
E
H an so n No
Fi le na m e
Sc al e
Da te
3d
W in g Ill in oi s Ai r N at io na l G ua rd Sp rin gf ie ld
, I llin oi s
3-
H an so n
Pr of es si on al
S er vi ce s In c.
S ou th
S ix th S tre et
Ph on e:
(2
) 7
-2
O kl am ho m a
C ity
, O K
8-
N G
B
ID
IQ
C on tr ac t #
W
L-
-D
B ro ad w ay E xt en si on
, S ui te
Ph on e:
(4
) 8
-2
C op yr ig ht H an so n Pr of es si on al S er vi ce s In c.
R
EP
A
IR
N D
I B U
IL
D
IN
G
P -1
SP
R
IN
G
FI
EL
D , I
L
TYPE B3 SUBMITTAL 12/12/2019
Si gn ed
/1
2/
Ex pi re s:
1/
/2
C :\U se rs
\a am
\D oc um en ts \M y R ev it\
0_ Ar ch _ a m er zT D
ZY
W
.rv t
4/ 1/
:5
5:
5 3
P M
/1
2/
R O
O M
F
IN
IS
H
S C
H
ED
UL
E, D O
O R
S C
H
ED
U
LE
G
LA
ZI
N G
E
LE
VA
TI
O N
S
AE-601
AA
M
JB
C
DOOR SCHEDULE
MARK
DOOR FRAME
NOTES
SIZE DOOR
TYPE TYPE
DETAIL
WD HGT THK HEAD JAMB SILL
100A 3'-8" 7'-0" 1 3/4" SGX S2 NEW KEYPAD ACCESS CONTROL AND MAGNETIC LOCK REQUIRED
100C 10'-0" 10'-0" 3/4" RDX STL
100D 10'-0" 10'-0" 3/4" RDX STL
100F 12'-0" 12'-0" 3/4" RDX STL
100M 3'-0" 7'-0" 1 3/4" SGX
100O 3'-0" 7'-0" S2
101A 3'-0" 7'-0" 1 3/4" SFI S2
102A 3'-0" 7'-0" 1 3/4" SFI S2
102B 3'-0" 7'-0" 1 3/4" SFGX S2 EXISTING KEYPAD ACCESS CONTROL AND MAG LOCK TO REMAIN 103A 3'-0" 7'-0" S2
104A 3'-0" 7'-0" 1 3/4" SFGI S2
105A 3'-0" 7'-0" 1 3/4" SFGX S2
107A 6'-0" 7'-0" 1 3/4" (2)SFGX D2
107B 3'-0" 7'-0" 1 3/4" SFI S2
108A 6'-0" 7'-0" 1 3/4" (2)SFGX D2
108B 6'-0" 7'-0" 1 3/4" (2)SFGX D2
109A 6'-0" 7'-0" 1 3/4" (2)SFI D2
110A 3'-0" 7'-0" 1 3/4" SFI S2
110B 3'-0" 7'-0" 1 3/4" SFGX S2
110C 8'-0" 10'-0" 3/4" RDX STL
110E 8'-0" 10'-0" 3/4" RDX STL
ROOM FINISH SCHEDULE
ROOM
NUMBER. ROOM NAME FLOOR FINISH BASE FINISH
WALL FINISHES CEILING
FINISH
CEILING
HEIGHT NOTESNORTH SOUTH EAST WEST
100 SHEET METAL SHOP EF-1 ICB-1 LP-1, PT-1 LP-1, PT-1 LP-1, PT-1 LP-1, PT-1 EXP EXPOSED TO STRUCTURE
101 OFFICE CPT-1 RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
102 VEST. CONC RB-1 PT-1 PT-1 PT-1 PT-1 GYP BD/
PT-1
9'-0"
103 CORR. CONC RB-1 PT-1 PT-1 PT-1 PT-1 ACT-1 9'-0"
104 WOMEN CFT-1 CB-1 CWT-1 CWT-1, PT-1 PT-1 CWT-1 GYP BD/
PT-1
9'-0"
105 MEN CFT-1 CB-1 CWT-1 CWT-1, PT-1 CWT-1, PT-1 CWT-1, PT-1 GYP BD/
PT-1
9'-0"
106 SHEET METAL SHOP #1 EF-1 ICB-1 LP-1 PT-1 PT-1 PT-1 EXP EXPOSED TO STRUCTURE
107 MECHANICAL EF-1 ICB-1 LP-1 PT-1 PT-1 LP-1 EXP EXPOSED TO STRUCTURE
108 METALS TECH. #2 EF-1 ICB-1 PT-1 LP-1 PT-1 LP-1 EXP EXPOSED TO STRUCTURE
109 METALS TECH #1 EF-1 ICB-1 PT-1 LP-1 PT-1 PT-1 EXP EXPOSED TO STRUCTURE
110 A.G.E. #1 EF-1 ICB-1 LP-1 LP-1 LP-1 PT-1 EXP EXPOSED TO STRUCTURE
111 COMM. CLOSET EF-1 ICB-1 PT-1 PT-1 PT-1 PT-1 EXP EXPOSED TO STRUCTURE
SCALE:NTS
DOOR TYPES
SCALE:NTS
FRAME TYPES
SCALE:NTS
GLAZING ELEVATIONS2
SCALE:NTS
GLAZING ELEVATIONS1
ROOM FINISH SCHEDULE NOTES:
1. PAINT THE FIVE (5) EXISTING MAIN FRAME COLUMNS AND BEAMS PT-1.
2. PAINT THE NEW COLUMNS AND FRAMING AT THE WEST CURTAINWALL INFILL PT-1.
3. PAINT THE REINSTALLED GUARDRAIL AT THE MEZZANINE SAFETY YELLOW.