A-002.pdf
PDF 365 KB Posted
- Attached to
- 183 CES Repair CRF Building P-17
- Solicitation number
- W50S7U-21-B-0001
- Issued by
-
Department of the Army National Guard
About this file
This document contains a federal contract opportunity and related government file. The federal contract opportunity is a solicitation seeking bids for repair work on Building P-17 at the 183rd Communications Electronics Squadron in Springfield, Illinois. The solicitation number is W50S7U-21-B-0001 and was issued by the Department of the Army National Guard. Bids are due on the response date identified in the solicitation. The government file contains the code and life safety plan and continuous air barrier plan for the building, with notes on air barrier inspection requirements and joining air barrier materials.
View the file
Other files
Show all 43
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
910 11
23 24
25 26
40 41 42 43
49 50
51 52
5657 58
777879
83 8485
868788
98 99
107108
111 112
115116 a b
3A
AIR FLOW
PUMP
AIR FLOW
PUMP
MEN
OFFICE
VEST.
CORR.
SHEET
METAL SHOP
#1
METALS
TECH. #2
METALS
TECH #1
MECHANICAL
107 WOMEN
A.G.E. #1
SHEET
METAL SHOP
#2
COMM.
CLOSET
342 SF B
1:150 3 1
538 SF S1
1:500 1 1
274 SF S1
1:500 1 1
6,385 SF S1
1:500 13 1
1,457 SF S1
1:500 3 1
446 SF S1
1:500 1 1
1,505 SF S1
1:500 3 1
35 SF S1
1:500 1 1
(91'-0")
(86'-0")
(51'-0")
(46'-0")
FUTURE GFGI
SANDING BOOTH
AND MEZZANINE
(N.I.C)
FUTURE GFGI
PAINT BOOTH
AND MEZZANINE
(N.I.C)
LIFE SAFETY LEGEND
(38'-0")
TRAVEL
DISTANCE
DENOTES
EXIT ROUTE
DENOTES
BUILDING EXIT
BREAK POINT
2,560 SF B
1:150 26 1
ROOM AREA
USE AND OCCUPANCY
CLASSIFICATION
REQUIRED EXITS
NUMBER OF OCCUPANTS
OCCUPANT LOAD FACTOR
PER UFC 3-600-01, TABLE 10-1
OCCUPANT LOAD NUMBER
AT EXIT COMPONENT
EXIT COMPONENT MAXIMUM
OCCUPANT CAPACITY NUMBER
MULTI-PURPOSE TYPE FIRE EXTINGUISHER -
WALL BRACKET
MOUNTED AT 48" AFF
PLUMBING FIXTURES
FIXTURE TYPE REQ. #
BUSINESS (B) - 3 OCCUPANTS
W.C. (MEN)
W.C. (WOMEN)
LAV. (MEN)
LAV. (WOMEN)
TOTALS (ROUND UP)
W.C. (MEN) 0.06+0.11 1
W.C. (WOMEN) UNISEX
LAV. (MEN)
LAV. (WOMEN) UNISEX
D.F. 1
SERVICE SINK
STORAGE AND MECHANICAL- [(S-1)] - 23 OCCUPANTS
W.C. (MEN) 1 PER 100 0.11
W.C. (WOMEN)
LAV. (MEN)
LAV. (WOMEN)
IBC 2018 TABLE 403.1
LOAD FACTOR (LF) (OCC/LF)
1 PER 100
1 PER 100
1 PER 100
(23/100)/2
1 PER 25 FOR FIRST(50) (3/25)/2 0.06
0.04
0.17≈
(3/40)/2 0.04
ACTUAL
CALC.
0.04+0.11 1
0.15≈
1 PER 25 FOR FIRST(50)
1 PER 40 FOR FIRST(80)
1 PER 40 FOR FIRST(80)
0.06+0.11 0.17≈
0.04+0.11 0.15≈
0.11 0.11 0.11
(3/40)/2 (3/25)/2 0.06
(23/100)/2 (23/100)/2 (23/100)/2
AE-301
AE-301
AE-301
AE-301
AE-301
AE-301
AE-301
AE-301
ENVELOPE 1
ENVELOPE 2
ENVELOPE 3
ENVELOPE 4
AE
-6
AE
-6
AE-501
LEGEND INDICATES PLANE OF
CONTINUOUS AIR BARRIER
AIR BARRIER SUMMARY
ENVELOPE SURFACE AREA
ENVELOPE 1
FLOOR AREA: =6,446 SF
WALL AREA: =7,562 SF
ROOF AREA: =7,000 SF
TOTAL: =21,008 SF
ENVELOPE 2
FLOOR AREA: =1,899 SF
WALL AREA: =2,995 SF
ROOF AREA: =2,100 SF
TOTAL: =6,994 SF
ENVELOPE 3
FLOOR AREA: =1,916 SF
WALL AREA: =2,948 SF
ROOF AREA: =2,000 SF
TOTAL: =6,864 SF
ENVELOPE 4
FLOOR AREA: =1,514 SF
WALL AREA: =1,691 SF
ROOF AREA: =1,646 SF
TOTAL: =4,851 SF
LA
YO
U T
DR
AW
N
RE
VI
EW
ED
D0 sheetsof XX
R
EV
IS
IO
N D
AT
E
H an so n No
Fi le na m e
Sc al e
Da te
3d
W in g Ill in oi s Ai r N at io na l G ua rd Sp rin gf ie ld
, I llin oi s
3-
H an so n
Pr of es si on al
S er vi ce s In c.
S ou th
S ix th S tre et
Ph on e:
(2
) 7
-2
O kl am ho m a
C ity
, O K
8-
N G
B
ID
IQ
C on tr ac t #
W
L-
-D
B ro ad w ay E xt en si on
, S ui te
Ph on e:
(4
) 8
-2
C op yr ig ht H an so n Pr of es si on al S er vi ce s In c.
R
EP
A
IR
N D
I B U
IL
D
IN
G
P -1
SP
R
IN
G
FI
EL
D , I
L
TYPE B3 SUBMITTAL 12/12/2019
Si gn ed
/1
2/
Ex pi re s:
1/
/2
C :\U se rs
\a am
\D oc um en ts \M y R ev it\
0_ Ar ch _ a m er zT D
ZY
W
.rv t
4/ 1/
:5
6:
4 2
P M
/1
2/
C O
D E
AN
D
L
IF
E
SA
FE
TY
P
LA
N
C O
N
TI
N U
O U
S
AI
R B
AR
R
IE
R
P
LA
N
A-002
AA
M
JB
C
SCALE: 1/8" = 1'-0"
1 CODE AND LIFE SAFETY PLAN
CODE SUMMARY
USE AND OCCUPANCY: (IBC 2015)
INDIVIDUAL CLASSIFICATION OF OCCUPANCY
BUSINESS: GROUP B (SECTION 304.1)
STORAGE: GROUP S-1 (SECTION 311.1)
PRELIMINARY CODE ANALYSIS BASED ON
NONSEPERATED MIXED USE OCCUPANCY USING THE
MOST RESTRICTIVE OCCUPANCY CLASSIFICATION S-1
(508.3.2)
OCCUPANCY GROUP(S) (NFPA 101-2018):
INDIVIDUAL CLASSIFICATION OF OCCUPANCIES:
BUSINESS (SECTION 6.1.11)
STORAGE- ORDINARY HAZARD (SECTION 6.1.13)
TYPE OF CONTRUCTION (IBC 2018 TABLE 601):
TYPE II-B WITH SPRINKLER SYSTEM
ALLOWABLE HEIGHT (IBC 2018):
55 FT PER TABLE 504.3
ACTUAL HEIGHT: 34 FT
ALLOWABLE AREA (IBC 2018):
PER SECTION 507.4 UNLIMITED AREA FOR ONE STORY
SPRINKLERED OF GROUP B AND S.
ACTUAL AREA: 12,433 GSF
*ACTUAL NUMBER OF OCCUPANTS WILL BE A TOTAL
OF 6.
SCALE: 1/8" = 1'-0"
2 CONTINUOUS AIR BARRIER PLAN
GENERAL NOTES
A. ACCORDING TO UFC 3-101-01 PARAGRAPH 3-6.3,
HANGAR BAYS AND MAINTENANCE BAY FACILITIES
REQUIRE AIR BARRIER INSPECTION ONLY.
CONTRACTOR SHALL NOTIFY CONTRACTING
OFFICER WHEN INSPECTION IS SCHEDULED.
B. THE CONTRACTOR SHALL REFERENCE WALL
SECTIONS AND DETAILS THAT GRAPHICALLY
INDICATE THE VISUAL PLANE OF THE INTENDED
CONTINUOUS AIR BARRIERS. THE CONTRACTOR
SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL
INTENDED CONTINUOUS AIR BARRIERS ARE IN
PLACE PRIOR TO TESTING.
C. THE CONTRACTOR SHALL JOIN AND SEAL THE AIR
BARRIER MATERIAL OF EACH ASSEMBLY IN A
FLEXIBLE MANNER TO THE AIR BARRIER MATERIAL
OF ADJACENT ASSEMBLIES ALLOWING FOR THE
RELATIVE MOVEMENT OF THESE ASSEMBLIES AND
COMPONENTS.
D. THE CONTRACTOR SHALL MAKE ALL PENETRATIONS
AIRTIGHT INCLUDING INCIDENTAL OPENINGS AT OR
AROUND ELECTRICAL BOXES, CONDUIT, PLUMBING,
AND OTHER ASSEMBLIES.
0 4' 8' 16'
1/8" = 1'-0"
N
PLAN NORTH
/0
7/
Ad de nd um
File details come from the government source that posted it. Updated .