A-001.pdf

PDF 199 KB Posted

Attached to
183 CES Repair CRF Building P-17
Solicitation number
W50S7U-21-B-0001
Issued by

About this file

This solicitation package seeks bids for repair work on Building P-17 at the 183rd Communications Squadron facility in Springfield, Illinois. The work includes repair and renovation of the existing Consolidated Repair Facility building. Bidders must submit bids in accordance with the specifications, plans, addendums, statement of work, and SF 1705 form included with Solicitation Number W50S7U-21-B-0001. A site visit is scheduled for potential bidders to inspect the building. The solicitation is issued by the Department of the Army National Guard for repair and construction services. Bids are due by the date specified in the solicitation package. The solicitation provides the relevant details needed for contractors to understand the scope of work and submit a responsive bid to repair Building P-17.

View the file

Other files

File Type Posted
Bid Opening Sign in.pdf PDF
Bid Opening Report- Repair CRF Building 17 W50S7U-21-B-0001.pdf PDF
W50S7U-21-B-0001-0001 Amendment 0001.pdf PDF
SECTION 074213.13 - FORMED METAL WALL PANELS.pdf PDF
DCFT 102008 RFI Repsonse 4 Roof and Wall Panels Sec 07413.13.docx DOCX document
DCFT 102008 RFI Response 3.docx DOCX document
DS Boot 2.jpg JPG image
DS Boot 3.jpg JPG image
DCFT 102008 RFI Response 3 - Door Hardware Sets.docx DOCX document
DS Boot 1.jpg JPG image
009113_1 fl - addenda_No1.pdf PDF
61650_Arch_amerzTDZYW-183WG-2090209.png PNG image
009113_2 fl - addenda_No2.pdf PDF
61650_Arch_amerzTDZYW-4-1309292.JPG JPG image
61650_Arch_amerzTDZYW-fsb-fdg-jv-logo-2ver-2090207.png PNG image
61650_Arch_amerzTDZYW-3-1309490.JPG JPG image
DCFT 102008 - RFI-RESPONSE 2.docx DOCX document
61650_Arch_amerzTDZYW-2-1309322.JPG JPG image
61650_Arch_amerzTDZYW-6-1309001.JPG JPG image
61650_Arch_amerzTDZYW-5-1307452.jpg JPG image
61650_Arch_amerzTDZYW-1-1151913.JPG JPG image
123661.16 - SOLID SURFACING COUNTERTOPS.pdf PDF
RFI Response 1 W50S7U-21-B-0001.pdf PDF
AD-101.pdf PDF
AE-310.pdf PDF
AE-103.pdf PDF
AE-311.pdf PDF
AE-601.pdf PDF
102800 - TOILET_ BATH_ AND LAUNDRY ACCESSORIES.pdf PDF
AE-301.pdf PDF
AE-401.pdf PDF
105113 - METAL LOCKERS.pdf PDF
090690 - COLOR SCHEDULE.pdf PDF
009113_3 fl - addenda_No3.pdf PDF
A-002.pdf PDF
P17 Reference Civil_Struct_Arch Dwgs Binder.zip ZIP file
Site Visit Sign-In Sheet CES Repair CRF P-17.pdf PDF
Site Visit Slides - CES Repair CRF P-17.pdf PDF
P17 Reference Canopy Door Dwgs Binder.zip ZIP file
P17 Reference Mech_Elect Dwgs Binder.zip ZIP file
SF 1705.pdf PDF
W50S7U-21-B-0001 -Solicitation - Repair Centralized Repair Facility Building P-17.pdf PDF
SOW - 102008 Final.pdf PDF
Show all 43

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

3'-0" 6"

2'-0" 1'-0"

1'-6"

7"

3"

WATER CLOSET

GRAB BAR

SANITARY

NAPKIN

DISPOSAL

TOILET TISSUE

DISPENSER

TOILET SEAT

COVER

DISPENSER

TYPICAL ACCESSIBLE WATER CLOSET BACK WALL TYPICAL ACCESSIBLE WATER CLOSET SIDE WALL

1'-4"

3' -4

LAVATORY

SOAP DISPENSER

MIRROR (ALIGN W/

LAVATORY

CENTERLINE UNO)

WALL MOUNTED LAVATORY

TO

S

PO

U

T 2'

-8

TO

S

PO

U

T 3'

-2

/2

ELECTRIC

WATER

COOLERS

SU

R

FA

C

E

3' -4

" M

AX

TO

R

EF

LE

C

TI

VE

1'-0" 3'-6"

3'-4"

3' -4

1'

-6

3"

FINISH FLOOR

FINISH FLOOR

DESCRIPTION MOUNTING HEIGHT

WATER CLOSET 15" AFF TO RIM

WATER CLOSET - ACCESSIBLE 17" AFF TO RIM

URINAL 24" AFF TO RIM

URINAL - ACCESSIBLE 17" AFF TO RIM

LAVATORY 34" AFF TO TOP

PAPER TOWEL DISPENSER 46" AFF TO BOTTOM/DISPENSER

SANITARY NAPKIN DISPOSAL 28" AFF TO TOP

TOILET PAPER DISPENSER 28" AFF TO TOP

GRAB BAR 34.5" AFF TO CENTER

ROBE HOOK/TOWEL BAR 60" AFF TO TOP

ROBE HOOK/TOWEL BAR -

ACCESSIBLE

48" AFF TO TOP

TOILET SEAT COVER DISPENSER 28" AFF TO TOP

TYPICAL ACCESSIBILITY, PLUMBING FIXTURE AND TOILET

ACCESSORY CLEARANCES, MOUNTING HEIGHTS AND DIMENSIONS

T.

O

. R

IM

2' -1

0" M

AX

TOILET ACCESSORY MOUNTING HEIGHT SCHEDULE

EDGE OF WALL

INSULATED PIPE

COVERING

WHERE

EXPOSED

MIN

1'-3"

MIN

1'-3"

PLUMBING FIXTURE

MINIMUM CLEARANCES

FLUSH VALVE

1- 1/

2" M

IN

ELECTRIC WATER COOLERS

ACCESSIBLE

STANDARD

5'-0" MIN CLR

HAND DRYER

BABY CHANGING STATION 48" AFF TO TOP

15" AFF TO BOTTOM

3' -4

COMBINATION

TOWEL

/ RECEPTACLE

PAPER TOWEL

DISPENSER/DISPOSAL

NOTE: ALL TOILET ACCESSORIES LISTED ABOVE MAY NOT BE IN CONTRACT.

MINIMUM CLEARANCE FOR STANDARD PLUMBING FIXTURE ACCESS

SHALL BE 15" TO CENTERLINE FROM BOTH SIDES ADJACENT WALL OR

OBSTRUCTION.

COAT HOOK 60" AFF TO TOP

COAT HOOK - ACCESSIBLE 48" AFF TO TOP

1/

2" M

IN MIN

1'-3"

MIN

1'-3"

PLUMBING FIXTURE

MINIMUM

CLEARANCES

PLUMBING FIXTURE

(URINAL AND WATER

CLOSET SIMILAR)

FLUSH VALVE

TYPICAL ACCESSIBLE URINAL MOUNTING

HEIGHT AND CLEARANCES

MIN

1'-3"

MIN

1'-3"1'-6 3/4"

6" 8"

1' -0

2' -3

1'-6 3/4"

AC

C

ES

SI

BL

E

2' -9

/2

ST

AN

D

AR

D

3' -4

NON-ADA

COMPLIANT

HEAD

ADA

COMPLIANT

WAND

GRAB BAR

FOLDING

BENCH

SHOWER

1' -6

3' -0

" M

AX

3' -1

0"

3' -0

" M

AX

TYPICAL ACCESSIBILITY

SIGNAGE MOUNTING HEIGHTS

TO

C

EN

TE

R O

F

SI

G N

5' -0

TYPICAL ACCESSIBILITY

SIGNAGE MOUNTING HEIGHTS

MAX

8"

TO

C

EN

TE

R O

F

SI

G N

5' -0

REFERENCE AG101 FOR AMERICAN AIRLINES

SIGNAGE STANDARDS

AD

J.

S H

EL

F

1' -3

" A

FF

AD

J.

S H

EL

F

4' -0

" A

FF

TO

H

O O

K

3' -1

0" A

FF

ACCESSIBLE

LOCKER

C U

R B

6"

STANDARD

LOCKER

ACT ACOUSTICAL CEILING TILE

ADA AMERICANS WITH DISABILITIES ACT

ADAAG ADA ACCESSIBILITY GUIDELINES

AFF ABOVE FINISH FLOOR

AHU AIR HANDLING UNIT

ALT ALTERNATE

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS

INSTITUTE

BO BOTTOM OF

BOT BOTTOM

BRG BEARING

BS BOTH SIDES

BTWN BETWEEN

CAB CABINET

CFMF COLD-FORMED METAL FRAMING

CG CORNER GUARD

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUOUS

CORR CORRIDOR

CPT CARPET

CTB CERAMIC TILE BASE

CFT CERAMIC FLOOR TILE

CWT CERAMIC WALL TILE

CTR CENTER

DBL DOUBLE

DEG DEGREE

DEMO DEMOLITION

DEPT DEPARTMENT

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DISP DISPENSER

DN DOWN

DR DOOR

DS DOWNSPOUT

DET DETAIL

DWG DRAWING

EA EACH

EIFS EXTERIOR INSULATION &

FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRIC (OR) ELECTRICAL

ELEV ELEVATOR

EQ EQUAL

EQUIP EQUIPMENT

EW EACH WAY

EXIST EXISTING

EXT EXTERIOR

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FF EL FINISH FLOOR ELEVATION

FG FINISHED GRADE

FLR FLOOR

FLUOR FLUORESCENT

FR FIRE RESISTIVE

FT FOOT (OR) FEET

FURG FURRING

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GC GENERAL CONTRACTOR

GDR GUARD RAIL

GEN GENERAL

GFCI GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GFGI GOVERNMENT FURNISHED

GOVERNMENT INSTALLED

GL GLASS

GRD GRADE

GYP BD GYPSUM BOARD

HM HOLLOW METAL

HORIZ HORIZONTAL

HT HEIGHT

HVAC HEATING, VENTILATING, &

AIR CONDITIONING

ICB INTEGRAL COVE BASE

ID INSIDE DIAMETER

INSUL INSULATE (OR) INSULATION

INT INTERIOR

JAN JANITOR

LAM LAMINATE

LAV LAVATORY

LIN LINEAR

LOC LOCATION

LTG LIGHTING

LVR LOUVER

MATL MATERIAL

MAX MAXIMUM

MECH MECHANICAL

MFR MANUFACTURER

MIN MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MO MASONRY OPENING

MTD MOUNTED

MTL METAL

NA NOT APPLICABLE

NIC NOT IN CONTRACT

NOM NOMINAL

NRC NOISE REDUCTION COEFFICIENT

NTS NOT TO SCALE

OA OVERALL

OC ON CENTER

OD OUTSIDE DIAMETER

OH OPPOSITE HAND

ORD OVERFLOW ROOF DRAIN

OVHD OVERHEAD

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATED

PT PAINT (INTERIOR)

PVC POLYVINYL CHLORIDE

QTF QUARRY TILE FLOOR

QTB QUARRY TILE BASE

QTY QUANTITY

R RADIUS (OR) RISER

RB RESILIENT BASE

RD ROOF DRAIN

REC RECESSED

REF REFERENCE (OR) REFRIGERATOR

REQD REQUIRED

REV REVISION

RF RESILIENT FLOORING

RM ROOM

RO ROUGH OPENING

SECT SECTION

SF SQUARE FOOT

SHTHG SHEATHING

SIM SIMILAR

SPEC SPECIFICATION(S)

SST STAINLESS STEEL

STC SOUND TRANSMISSION CLASSIFICATION

STD STANDARD

STL STEEL

STRUCT STRUCTURAL (OR) STRUCTURE

T TREAD

T&B TOP AND BOTTOM

TBD TO BE DETERMINED

TD TOWEL DISPENSER

TO TOP OF

TOC TOP OF CONCRETE

TOJ TOP OF JOIST

TOM TOP OF MASONRY

TOS TOP OF STEEL

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

WH WALL HYDRANT (OR) WATER HEATER

XFMR TRANSFORMER

Y NOT USED

Z NOT USED

ARCHITECTURAL ABBREVIATIONS

GROUND FLOOR PLAN

SCALE:1/8"=1'-0"

A401

A - 101

DRAWING TYPES LEGEND

0- GENERAL INFORMATION

1 - PLANS (HORIZONTAL VIEWS)

2 - ELEVATIONS (VERTICAL VIEWS)

3 - SECTIONS (SECTIONAL VIEWS)

4 - ENLARGED VIEWS (PLANS, ELEVATIONS OR SECTIONS)

5 - DETAILS

6 - SCHEDULES & DIAGRAMS

DISCIPLINE TYPE (ARCHITECTURE SHOWN)

DRAWING TYPE (PLAN, ELEVATION, ETC.)

SERIES/ FLOOR DESIGNATION

DETAIL CALLOUT

ENLARGED PLAN OR DETAIL

ON SHEET INDICATED

A201

INTERIOR ELEVATION CALLOUT

ARROWS INDICATE INTERIOR

ELEVATION ON SHEET

INDICATED

STRUCTURAL GRIDS

AS INDICATED ON

DRAWINGS

A

BUILDING SECTION CALLOUT

ARROWS INDICATE BUILDING

SECTION ON SHEET INDICATED

A301

SECTION CALLOUT

ARROW INDICATE WALL SECTION ON

SHEET INDICATED

A302

ROOM NAME

ROOM NAME & NUMBER SYMBOL

REFER TO ROOM FINISH SCHEDULE

101A

DOOR NUMBER SYMBOL

REFER TO DOOR SCHEDULE

DOOR NUMBER WITH *

INDICATES ACCESS CONTROL

HARDWARE

PARTITION TYPE SYMBOL

REFER TO PARTITION TYPES

GLAZING TYPE SYMBOL

REFER TO GLAZING TYPES

A

AL1

REVISION SYMBOL

REFER TO SHEET BORDER FOR

REVISION HISTORY

ELEVATION DATUM SYMBOL

INDICATES DATUM ELEVATION AS

INDICATED

Bottom Text Top Text

DISCIPLINE MODIFIER (ELEMENTS SHOWN)

ARCHITECTURAL SYMBOLS LEGEND

DRAWING TITLE

0 4' 8' 16'

1/8" = 1'-0"

NORTH ARROW AND SCALE

A301

EXTERIOR ELEVATION CALLOUT

ARROW INDICATE ELEVATION ON

SHEET INDICATED

A201

N

FLOOR LEVEL

KEYNOTE SYMBOL

INDICATES INFORMATION FOUND IN

KEYNOTES ON PLAN

3 DIGIT ROOM NUMERAL

LOCATED IN THE

BOTTOM RIGHT

SHEET CORNER

0 2' 4' 8'

1/4" = 1'-0"

FINISH

FLOOR

DECK

SCHEDULED

CLG8" CMU

A2

5/8" GYP BD

(BOTH SIDES)

FINISH

FLOOR

DECK

SLOTTED

DEFL TRACK

SCHEDULED

CLG

STEEL RUNNER

CHANNEL

BASE AS

SCHEDULED

6" STUDS

AT 16" OC

NON-RATED PARTITION AS

SHOWN

F1

NON-RATED PARTITION

AS SHOWN ABOVE

FINISHED FLOOR

BASE AS

SCHEDULED

6" M

IN

UNFACED

ACO BATTS

A3

NON-RATED PARTITION

AS SHOWN ABOVE WITH

GYP BD ONE SIDE ONLY

A4

NON-RATED PARTITION

AS SHOWN ABOVE WITH

2 1/2" STUDS AND GYP BD

ONE SIDE ONLY

NON-RATED PARTITION AS

SHOWN WITH MASONRY CELL

INSULATION

F2

LA

YO

U T

DR

AW

N

RE

VI

EW

ED

D0 sheetsof XX

R

EV

IS

IO

N D

AT

E

H an so n No

Fi le na m e

Sc al e

Da te

3d

W in g Ill in oi s Ai r N at io na l G ua rd Sp rin gf ie ld

, I llin oi s

3-

H an so n

Pr of es si on al

S er vi ce s In c.

S ou th

S ix th S tre et

Ph on e:

(2

) 7

-2

O kl am ho m a

C ity

, O K

8-

N G

B

ID

IQ

C on tr ac t #

W

L-

-D

B ro ad w ay E xt en si on

, S ui te

Ph on e:

(4

) 8

-2

C op yr ig ht H an so n Pr of es si on al S er vi ce s In c.

R

EP

A

IR

N D

I B U

IL

D

IN

G

P -1

SP

R

IN

G

FI

EL

D , I

L

TYPE B3 SUBMITTAL 12/12/2019

Si gn ed

/1

2/

Ex pi re s:

1/

/2

C :\U se rs

\a am

\D oc um en ts \M y R ev it\

0_ Ar ch _ a m er zT D

ZY

W

.rv t

4/ 1/

:5

5:

2 1

P M

/1

2/

AR

C

H

IT

EC

TU

R

AL

A B

B

RE

VI

AT

IO

N

S, T

YP

IC

AL

AC

C

ES

SI

B

IL

IT

Y M

O U

NT

IN

G H

EI

G

H

TS

S

YM

B

O

LS

LE

G

EN

D

A-001

AA

M

JB

C

SCALE:NTS

PARTITION TYPES1

/0

7/

Ad de nd um

File details come from the government source that posted it. Updated .