This document is a comprehensive 2024 Annual Crane Inspection Report for three monorail cranes located at the Sarasota County Venice Gardens Water Treatment Facility, prepared by National Crane Services, Inc. The report covers detailed inspections of three separate cranes: VGWTF-01 (High Service Pump Building), VGWTF-02 (Building 1), and VGWTF-03 (Building 2). Each crane was evaluated for various technical and safety aspects, including electrical systems, pendant controls, hoist systems, trolley systems, monorail systems, and load testing. The inspections revealed multiple recommendations and deficiencies across the cranes, including the need for warning labels, preventative maintenance programs, load testing, internal gearcase inspections, and specific mechanical repairs.

The report identifies significant maintenance requirements for each crane, with most cranes being categorized as either "Deficient" or requiring multiple recommendations for repairs and improvements. Key issues include broken bus bar mounting clips, dirty electrical systems, dry-rotted pendant cords, lack of internal gearcase inspections, and absence of proper maintenance records. For VGWTF-01 and VGWTF-02, the cranes were deemed deficient and recommended to be removed from service until repairs are made. The inspection was conducted on 06/28/2024 by surveyor Donald O'Rourke, and the report provides a detailed certification process notice outlining the owner's responsibilities for ongoing maintenance, safety checks, and periodic examinations of the equipment.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sarasota County Venice Gardens Water Treatment Facility

1350 Jacaranda Blvd. Venice, FL 34293

2024 Annual Crane Inspections

20537 U.S. Highway 301, Dade City, FL 33523

PH: (352) 583-9996

www.natlcrane.com

Table of Contents Deficiencies Recommendations Section

Annual Inspection Report - High Service Pump Building

Monorail Crane: VGWTF-01 2 7 1.0

Annual Inspection Report - Building 1 Monorail Crane: VGWTF-02 1 5 2.0

Annual Inspection Report - Building 2 Monorail Crane: VGWTF-03 0 6 3.0

Signature Page 4.0

Summary Page 5.0

Printed on 06/29/2024

National Crane Services

Table of ContentsPowered by INSPECTALL http://www.inspectall.com/ http://www.inspectall.com/

National Crane Services, Inc.

20537 U.S. Highway 301, Dade City, FL 33523 (352) 583-9996 FAX (352) 583-9997 www.natlcrane.com

DEFICIENCY REPORT

Accredited by the U.S. Department of Labor under 29 CFR part 1919

Owner ID: VGWTF-01

Owner: Sarasota County, Venice Gardens Water Treatment Facility

Address: 1350 Jacaranda Blvd., Venice, FL 34293

Description: Crane

Type of Equipment: Monorail Crane

Manufacture: Chester Model: WDMT41S Serial Number: WC3135

Location: Remains at Worksite

Describe: High Service Pump Building

Service Status at time of survey: Lifting

Test Loads Applied:

Configuration Capacity Load Applied

Fixed Capacity 4,000 LB

Type of Proof Load: Functional Testing Only Basis of Capacities: Manufacturer's Load Rating

The undersigned, being authorized to do so, hereby tenders notification of the following listed uncorrected deficiencies, found upon test and/or examination of the described equipment in accordance with the requirements of 29 CFR part 1910, 1926, 1918, and/or 1919, as applicable, to constitute in the opinion on the undersigned a current unsatisfactory condition:

See Attached "Inspection Report" Form

Under the applicable requirements of 29 CFR part 1919, the issuance of any certification of examination is prohibited until such time as correction of deficiencies has been verified by the undersigned.

Name and address of accredited or otherwise authorized organization making this test and/or examination:

National Crane Services INC., 20537 US Highway 301, Dade City, FL 33523

Name and address of authorized person carrying out this test and/or examination:

Donald O'Rourke 20537 US Highway 301, Dade City, FL 33523

Position of signatory in the organization making the test and/or examination:

Donald O'Rourke, Chief Surveyor Signature:

Date:6/28/2024

Printed on 06/29/2024

National Crane Services

1.0Powered by INSPECTALL http://www.inspectall.com/

20537 U.S. Highway 301

Dade City, FL 33523

(352) 583-9996

Monorail Crane

Completed by: Donald O'Rourke on 06/28/2024

Location: High Service Pump Building

Equipment Number:

VGWTF-01

Status: Deficient

Description: Crane

Location: Remains at Worksite

Basis of Capacities: Manufacturer's Load Rating

Type of Service: Lifting

Power: Electrical

Control Type: Pendant

Crane Configuration: Hoist and Trolley

Lifting Medium, Hoist: Wire Rope

Manufacturer: Chester

Model Number: WDMT41S

Serial Number: WC3135

Capacity: 4,000 LB

Trolley Manufacturer: Chester

Trolley Model Number: Unknown

Trolley Serial Number: Unknown

Trolley Capacity: 4,000 LB

Periodic Inspection Report Sarasota County, Venice Gardens Water Treatment Facility 1350 Jacaranda Blvd.

Venice, FL 34293

FolderID: 220149 FormID: 8361891

Priorities Found: 2 7 36

Inspection Data

1. INSPECTION DATE 06/28/2024

2. TYPE OF INSPECTION Annual

3. LOAD TEST PERFORMED No

4. SURVEYOR #1 Donald O'Rourke

5. SURVEYOR #2

Safety

6. SAFETY AND MACHINE GUARDS Satisfactory

7. WARNING DEVICES Not Applicable

8. WARNING LABEL Recommendation

There is no warning label IAW ASME B30.16 installed on the unit. Install.

9. OVERLOAD DEVICE Not Applicable

10. TRAVEL LIMITS Not Applicable

11. CAPACITIES POSTED AND VISIBLE Satisfactory

12. INSPECTION, MAINTENANCE, AND REPAIR RECORDS Satisfactory

Continue to maintain reports of all repairs, maintenance, and inspections made to the unit.

13. MAINTENANCE PERFORMED IAW OEM SPECIFICATION Recommendation

There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

14. LOAD TEST RECORD Recommendation

There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Electrical System

15. MAIN DISCONNECT - FLOOR Satisfactory

Printed on 06/29/2024

National Crane Services

1.1Powered by INSPECTALL http://www.inspectall.com/

16. CONTACTORS Satisfactory

17. VARIABLE FREQUENCY DRIVES Not Applicable

18. RESISTOR BANKS Not Applicable

19. CONTROL ENCLOSURES AND J-BOXES Satisfactory

20. CONDUCTORS AND COLLECTORS - MONORAIL Deficiency

Most of the buss bar mounting clip is broken. Repair.

The buss bar system is extremely dirty. Clean.

21. MONORAIL CONDUCTOR TYPE Buss Bar System

22. WIRING Satisfactory

Pendant Controls

23. PENDANT STATION Recommendation

The pendant cord is dry rotted and cracked. Repair.

24. PUSH BUTTONS Satisfactory

25. FUNCTIONS IDENTIFIED Satisfactory

26. STRAIN RELIEF Satisfactory

27. DUST COVERS Satisfactory

28. WARNING ALARM Not Applicable

Hoist System

29. FRAME Not Applicable

30. MOTOR(S) Satisfactory

31. GEAR ASSEMBLIES AND SEALS Recommendation

During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

32. BEARING ASSEMBLIES Satisfactory

33. DRUM Satisfactory

34. DRUM ANCHOR TYPE Buttons

35. WIRE ROPE DEAD END Not Applicable

36. SHEAVE ASSEMBLIES AND EQUALIZER Satisfactory

37. BRAKE - HOLDING Satisfactory

38. BRAKE - HOLDING LINING THICKNESS Add Measurement

39. HOLDING LINING THICKNESS

MEASUREMENT

.437"

40. BRAKE - HOLDING AIR GAP Add Measurement

The air gap is .020".

41. HOLDING AIR GAP

MEASUREMENT

Adjusted to .020"

42. BRAKE - LOAD LOWERING Recommendation

During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

43. BRAKE - LOAD LOWERING TYPE Mechanical

44. BRAKE - LOAD LOWERING INTERNAL INSPECTION No

45. LOAD BLOCK ASSEMBLY Satisfactory

46. LOAD BLOCK INFORMATION - ROPE

NUMBER OF SHEAVES CAPACITY

2 4,000 LB

47. LOAD HOOK Satisfactory

Printed on 06/29/2024

National Crane Services

1.2Powered by INSPECTALL http://www.inspectall.com/

48. LOAD HOOK THROAT MEASUREMENT

THROAT

1 1/2"

49. LOAD HOOK LATCH Satisfactory

50. LOAD HOOK SWIVEL Satisfactory

51. SUPPORT HOOK Not Applicable

52. PRIMARY UPPER LIMIT SWITCH Satisfactory

53. SECONDARY UPPER LIMIT SWITCH Not Applicable

54. LOWER LIMIT SWITCH Not Applicable

Trolley System

55. SIDE FRAMES AND LOAD BRACKETS Satisfactory

56. SUSPENSION BOLTS AND NUTS Satisfactory

57. TROLLEY WHEEL SPACING Satisfactory

58. HOIST MOUNTING LUG Satisfactory

59. MOTOR(S) Satisfactory

60. GEAR ASSEMBLIES AND SEALS Recommendation

During this inspection, there was no internal inspection of the trolley gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the trolley gearcase for internal inspection.

61. BEARING ASSEMBLIES Satisfactory

62. DRIVE Satisfactory

63. DRIVE TYPE Electrical

64. BRAKE Not Applicable

65. WHEELS Satisfactory

66. WHEEL INFORMATION

DRIVES IDLERS

2 4

67. DROP LUGS Not Applicable

68. BUMPERS Not Applicable

69. END STOPS Satisfactory

Monorail System

70. SUPPORTS AND BRACKETS Satisfactory

71. WELDS Satisfactory

72. BOLTS, NUTS, AND/OR WEDGE WASHERS Satisfactory

73. TRACK GAP Satisfactory

74. INTERLOCKS Not Applicable

75. TRACK SWITCHES Not Applicable

76. MONORAIL BEAM Satisfactory

Wire Rope

77. HOIST - WIRE ROPE CONDITION Satisfactory

78. HOIST - WIRE ROPE INFORMATION

DIAMETER PARTS

.257" 4

Load Testing

79. LOAD TEST RESULTS Not Applicable

80. TYPE OF WEIGHT USED FOR LOAD TESTING

DESCRIPTION

Functional Testing Only

Printed on 06/29/2024

National Crane Services

1.3Powered by INSPECTALL http://www.inspectall.com/

81. TEST #1

CONFIGURATION CAPACITY LOAD APPLIED

Fixed Capacity 4,000 LB

82. TEST #2

CONFIGURATION CAPACITY LOAD APPLIED

Status

83. INSPECTION RESULTS Deficient

The crane is deficient and should be removed from service until repairs are made.

84. REMARKS AND LIMITATIONS

Please refer to the signature page at the end of the inspection report for the "Certification Process Notice to Owner" for your scheduled maintenance responsibilities. The summary follows the signature page if any items were noted that need attention.

85. ANY LIMITATIONS No

86. REMARKS

87. REMARKS (CONTINUE)

Printed on 06/29/2024

National Crane Services

1.4Powered by INSPECTALL http://www.inspectall.com/

DEFICIENCY REPORT

Accredited by the U.S. Department of Labor under 29 CFR part 1919

Owner ID: VGWTF-02

Owner: Sarasota County, Venice Gardens Water Treatment Facility

Address: 1350 Jacaranda Blvd., Venice, FL 34293

Description: Crane

Type of Equipment: Monorail Crane

Manufacture: Coffing Model: EC-2008-3 Serial Number: EC1-C-383-NDD

Location: Remains at Worksite

Describe: Building 1

Service Status at time of survey: Lifting

Test Loads Applied:

Configuration Capacity Load Applied

Fixed Capacity 2,000 LB

Type of Proof Load: Functional Testing Only Basis of Capacities: Manufacturer's Load Rating

The undersigned, being authorized to do so, hereby tenders notification of the following listed uncorrected deficiencies, found upon test and/or examination of the described equipment in accordance with the requirements of 29 CFR part 1910, 1926, 1918, and/or 1919, as applicable, to constitute in the opinion on the undersigned a current unsatisfactory condition:

See Attached "Inspection Report" Form

Under the applicable requirements of 29 CFR part 1919, the issuance of any certification of examination is prohibited until such time as correction of deficiencies has been verified by the undersigned.

Name and address of accredited or otherwise authorized organization making this test and/or examination:

National Crane Services INC., 20537 US Highway 301, Dade City, FL 33523

Name and address of authorized person carrying out this test and/or examination:

Donald O'Rourke 20537 US Highway 301, Dade City, FL 33523

Position of signatory in the organization making the test and/or examination:

Donald O'Rourke, Chief Surveyor Signature:

Date:6/28/2024

Printed on 06/29/2024

National Crane Services

2.0Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

Dade City, FL 33523

(352) 583-9996

Monorail Crane

Completed by: Donald O'Rourke on 06/28/2024

Location: Building 1

Equipment Number:

VGWTF-02

Status: Deficient

Description: Crane

Location: Remains at Worksite

Basis of Capacities: Manufacturer's Load Rating

Type of Service: Lifting

Power: Electrical

Control Type: Pendant

Crane Configuration: Hoist and Trolley

Lifting Medium, Hoist: Load Chain

Manufacturer: Coffing

Model Number: EC-2008-3

Serial Number: EC1-C-383-NDD

Capacity: 2,000 LB

Trolley Manufacturer: Coffing

Trolley Model Number: Unknown

Trolley Serial Number: Unknown

Trolley Capacity: 2,000 LB

Periodic Inspection Report Sarasota County, Venice Gardens Water Treatment Facility 1350 Jacaranda Blvd.

Venice, FL 34293

FolderID: 220149 FormID: 8361892

Priorities Found: 1 5 38

Inspection Data

1. INSPECTION DATE 06/28/2024

2. TYPE OF INSPECTION Annual

3. LOAD TEST PERFORMED No

4. SURVEYOR #1 Donald O'Rourke

5. SURVEYOR #2

Safety

6. SAFETY AND MACHINE GUARDS Satisfactory

7. WARNING DEVICES Not Applicable

8. WARNING LABEL Satisfactory

9. OVERLOAD DEVICE Not Applicable

10. TRAVEL LIMITS Not Applicable

11. CAPACITIES POSTED AND VISIBLE Satisfactory

12. INSPECTION, MAINTENANCE, AND REPAIR RECORDS Satisfactory

Continue to maintain reports of all repairs, maintenance, and inspections made to the unit.

13. MAINTENANCE PERFORMED IAW OEM SPECIFICATION Recommendation

There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

14. LOAD TEST RECORD Recommendation

There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Electrical System

15. MAIN DISCONNECT - FLOOR Satisfactory

16. CONTACTORS Satisfactory

Printed on 06/29/2024

National Crane Services

2.1Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

17. VARIABLE FREQUENCY DRIVES Not Applicable

18. RESISTOR BANKS Not Applicable

19. CONTROL ENCLOSURES AND J-BOXES Satisfactory

20. CONDUCTORS AND COLLECTORS - MONORAIL Satisfactory

21. MONORAIL CONDUCTOR TYPE Buss Bar System

22. WIRING Satisfactory

Pendant Controls

23. PENDANT STATION Satisfactory

24. PUSH BUTTONS Satisfactory

25. FUNCTIONS IDENTIFIED Satisfactory

26. STRAIN RELIEF Satisfactory

27. DUST COVERS Satisfactory

28. WARNING ALARM Not Applicable

Hoist System

29. FRAME Not Applicable

30. MOTOR(S) Satisfactory

31. GEAR ASSEMBLIES AND SEALS Recommendation

During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

32. BEARING ASSEMBLIES Satisfactory

33. SPROCKETS Satisfactory

34. CHAIN OVER TRAVEL RESTRAINT Satisfactory

35. BRAKE - HOLDING Satisfactory

36. BRAKE - HOLDING LINING THICKNESS Inaccessible Without Disassembly

The minimum allowable disc thickness is .162".

37. BRAKE - HOLDING AIR GAP Add Measurement

The air gap is between .015" and .040".

38. HOLDING AIR GAP

MEASUREMENT

.025"

39. BRAKE - LOAD LOWERING Recommendation

During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

40. BRAKE - LOAD LOWERING TYPE Mechanical

41. BRAKE - LOAD LOWERING INTERNAL INSPECTION No

42. LOAD BLOCK ASSEMBLY Satisfactory

43. LOAD BLOCK INFORMATION - CHAIN

NUMBER OF SPROCKETS CAPACITY

1 2,000 LB

44. LOAD HOOK Satisfactory

45. LOAD HOOK THROAT MEASUREMENT

THROAT

1 1/8"

46. LOAD HOOK LATCH Satisfactory

47. LOAD HOOK SWIVEL Satisfactory

48. SUPPORT HOOK Not Applicable

49. PRIMARY UPPER LIMIT SWITCH Satisfactory

Printed on 06/29/2024

National Crane Services

2.2Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

50. SECONDARY UPPER LIMIT SWITCH Not Applicable

51. LOWER LIMIT SWITCH Satisfactory

52. CHAIN BUCKET Satisfactory

Trolley System

53. SIDE FRAMES AND LOAD BRACKETS Satisfactory

54. SUSPENSION BOLTS AND NUTS Satisfactory

55. TROLLEY WHEEL SPACING Satisfactory

56. HOIST MOUNTING LUG Satisfactory

57. MOTOR(S) Not Applicable

58. GEAR ASSEMBLIES AND SEALS Not Applicable

59. BEARING ASSEMBLIES Satisfactory

60. DRIVE Not Applicable

61. BRAKE Not Applicable

62. WHEELS Satisfactory

63. WHEEL INFORMATION

DRIVES IDLERS

0 4

64. DROP LUGS Satisfactory

65. BUMPERS Not Applicable

66. END STOPS Satisfactory

Monorail System

67. SUPPORTS AND BRACKETS Satisfactory

68. WELDS Satisfactory

69. BOLTS, NUTS, AND/OR WEDGE WASHERS Satisfactory

70. TRACK GAP Not Applicable

71. INTERLOCKS Not Applicable

72. TRACK SWITCHES Not Applicable

73. MONORAIL BEAM Satisfactory

Load Chain

74. HOIST - CHAIN CONDITION Recommendation

The load chain is dry and rusty. ASME B30 states that the lubricant applied shall be of the type that does not hinder the visual inspection. Lubricate.

75. HOIST - CHAIN INFORMATION

DIAMETER PARTS

.247" 2

76. HOIST - CHAIN PITCH

DIMENSION

13 1/4"

17 Links - Outside to Outside - Replace @ 13 7/16"

Load Testing

77. LOAD TEST RESULTS Not Applicable

78. TYPE OF WEIGHT USED FOR LOAD TESTING

DESCRIPTION

Functional Testing Only

79. TEST #1

CONFIGURATION CAPACITY LOAD APPLIED

Fixed Capacity 2,000 LB

Printed on 06/29/2024

National Crane Services

2.3Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

80. TEST #2

Status

81. INSPECTION RESULTS Deficient

The crane is not connected to power at the time of inspection. It is the owner's responsibility to properly connect the crane to power and to inspect it prior to use to ensure the safe operation of the crane.

82. REMARKS AND LIMITATIONS

Please refer to the signature page at the end of the inspection report for the "Certification Process Notice to Owner" for your scheduled maintenance responsibilities. The summary follows the signature page if any items were noted that need attention.

83. ANY LIMITATIONS No

84. REMARKS

85. REMARKS (CONTINUE)

Printed on 06/29/2024

National Crane Services

2.4Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

EQUIPMENT CERTIFICATION OF EXAMINATION

Accredited by the U.S. Department of Labor under 29 CFR part 1919

Certification Number: SCV-VGWTF03-0624 Owner ID: VGWTF-03

Owner: Sarasota County, Venice Gardens Water Treatment Facility

Address: 1350 Jacaranda Blvd., Venice, FL 34293

Description: Crane

Type of Equipment: Monorail Crane

Manufacture: Harrington Model: ES3-573 Serial Number: 3660

Location: Remains at Worksite

Describe: Building 2

Service Status at time of survey: Lifting

Test Loads Applied:

Configuration Capacity Load Applied

Fixed Capacity 2,000 LB

Type of Proof Load: Functional Testing Only Basis of Capacities: Manufacturer's Load Rating

Remarks and/or Limitations Imposed: Please refer to the signature page at the end of the inspection report for the "Certification Process Notice to Owner" for your scheduled maintenance responsibilities. The summary follows the signature page if any items were noted that need attention.

I certify that on 06/28/2024, the above described device was examined by the undersigned or his authorized representative;

that said examination met all respects with the requirements of 29 CFR part 1910, 1926, 1918, and/or 1919 or with requirements declared compatible under the provision of 29 CFR 1918.13(B)(2); that if any deficiencies considered to constitute an unsatisfactory condition have been corrected; and that the device has been found to be in compliance in all applicable respect with governing requirements

Name and address of accredited or otherwise authorized organization making this test and/or examination:

National Crane Services INC., 20537 US Highway 301, Dade City, FL 33523

Name and address of authorized person carrying out this test and/or examination:

Donald O'Rourke 20537 US Highway 301, Dade City, FL 33523

Position of signatory in the organization making the test and/or examination:

Donald O'Rourke, Chief Surveyor Signature:

Date:6/28/2024

Printed on 06/29/2024

National Crane Services

3.0Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

Dade City, FL 33523

(352) 583-9996

Monorail Crane

Completed by: Donald O'Rourke on 06/28/2024

Location: Building 2

Equipment Number:

VGWTF-03

Status: In Service

Certification Number: SCV-VGWTF03-0624

Description: Crane

Location: Remains at Worksite

Basis of Capacities: Manufacturer's Load Rating

Type of Service: Lifting

Power: Electrical

Control Type: Pendant

Crane Configuration: Hoist and Trolley

Lifting Medium, Hoist: Load Chain

Manufacturer: Harrington

Model Number: ES3-573

Serial Number: 3660

Capacity: 2,000 LB

Trolley Manufacturer: Harrington

Trolley Model Number: TF-673

Trolley Serial Number: 3550

Trolley Capacity: 2,000 LB

Periodic Inspection Report Sarasota County, Venice Gardens Water Treatment Facility 1350 Jacaranda Blvd.

Venice, FL 34293

FolderID: 220149 FormID: 8361893

Priorities Found: 6 40

Inspection Data

1. INSPECTION DATE 06/28/2024

2. TYPE OF INSPECTION Annual

3. LOAD TEST PERFORMED No

4. SURVEYOR #1 Donald O'Rourke

5. SURVEYOR #2

Safety

6. SAFETY AND MACHINE GUARDS Satisfactory

7. WARNING DEVICES Not Applicable

8. WARNING LABEL Satisfactory

9. OVERLOAD DEVICE Not Applicable

10. TRAVEL LIMITS Not Applicable

11. CAPACITIES POSTED AND VISIBLE Recommendation

The capacity of the monorail beam is not marked on the monorail beam. Mark.

12. INSPECTION, MAINTENANCE, AND REPAIR RECORDS Satisfactory

Continue to maintain reports of all repairs, maintenance, and inspections made to the unit.

13. MAINTENANCE PERFORMED IAW OEM SPECIFICATION Recommendation

There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

14. LOAD TEST RECORD Recommendation

There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Electrical System

Printed on 06/29/2024

National Crane Services

3.1Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

15. MAIN DISCONNECT - FLOOR Satisfactory

16. CONTACTORS Satisfactory

17. VARIABLE FREQUENCY DRIVES Not Applicable

18. RESISTOR BANKS Not Applicable

19. CONTROL ENCLOSURES AND J-BOXES Satisfactory

20. CONDUCTORS AND COLLECTORS - MONORAIL Satisfactory

21. MONORAIL CONDUCTOR TYPE Festoon System

22. WIRING Satisfactory

Pendant Controls

23. PENDANT STATION Satisfactory

24. PUSH BUTTONS Satisfactory

25. FUNCTIONS IDENTIFIED Satisfactory

26. STRAIN RELIEF Satisfactory

27. DUST COVERS Satisfactory

28. WARNING ALARM Not Applicable

Hoist System

29. FRAME Not Applicable

30. MOTOR(S) Satisfactory

31. GEAR ASSEMBLIES AND SEALS Recommendation

During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

32. BEARING ASSEMBLIES Satisfactory

33. SPROCKETS Satisfactory

34. CHAIN OVER TRAVEL RESTRAINT Satisfactory

35. BRAKE - HOLDING Satisfactory

36. BRAKE - HOLDING LINING THICKNESS Satisfactory

Replace the brake if the "A" measurement is smaller than 41 mm.

37. BRAKE - HOLDING AIR GAP Self Adjusting

38. BRAKE - LOAD LOWERING Recommendation

During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

39. BRAKE - LOAD LOWERING TYPE Mechanical

40. BRAKE - LOAD LOWERING INTERNAL INSPECTION No

41. LOAD BLOCK ASSEMBLY Satisfactory

42. LOAD BLOCK INFORMATION - CHAIN

NUMBER OF SPROCKETS CAPACITY

1 2,000 LB

43. LOAD HOOK Satisfactory

44. LOAD HOOK THROAT MEASUREMENT

THROAT

1 3/8"

45. LOAD HOOK LATCH Satisfactory

46. LOAD HOOK SWIVEL Satisfactory

47. SUPPORT HOOK Satisfactory

48. SUPPORT HOOK THROAT MEASUREMENT

THROAT

1 3/8"

Printed on 06/29/2024

National Crane Services

3.2Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

49. SUPPORT HOOK LATCH Satisfactory

50. SUPPORT HOOK SWIVEL Satisfactory

51. PRIMARY UPPER LIMIT SWITCH Satisfactory

52. SECONDARY UPPER LIMIT SWITCH Not Applicable

53. LOWER LIMIT SWITCH Satisfactory

54. CHAIN BUCKET Satisfactory

Trolley System

55. SIDE FRAMES AND LOAD BRACKETS Satisfactory

56. SUSPENSION BOLTS AND NUTS Satisfactory

57. TROLLEY WHEEL SPACING Recommendation

The trolley wheel spacing is not set IAW OEM specifications. Repair.

58. HOIST MOUNTING LUG Satisfactory

59. MOTOR(S) Not Applicable

60. GEAR ASSEMBLIES AND SEALS Not Applicable

61. BEARING ASSEMBLIES Satisfactory

62. DRIVE Not Applicable

63. BRAKE Not Applicable

64. WHEELS Satisfactory

65. WHEEL INFORMATION

DRIVES IDLERS

0 4

66. DROP LUGS Not Applicable

67. BUMPERS Not Applicable

68. END STOPS Satisfactory

Monorail System

69. SUPPORTS AND BRACKETS Satisfactory

70. WELDS Satisfactory

71. BOLTS, NUTS, AND/OR WEDGE WASHERS Satisfactory

72. TRACK GAP Not Applicable

73. INTERLOCKS Not Applicable

74. TRACK SWITCHES Not Applicable

75. MONORAIL BEAM Satisfactory

Load Chain

76. HOIST - CHAIN CONDITION Satisfactory

77. HOIST - CHAIN INFORMATION

DIAMETER PARTS

.244" 2

78. HOIST - CHAIN PITCH

DIMENSION

3.76"

5 Links - Inside to Inside - Replace @ 3.86"

Load Testing

79. LOAD TEST RESULTS Not Applicable

80. TYPE OF WEIGHT USED FOR LOAD TESTING

DESCRIPTION

Functional Testing Only

Printed on 06/29/2024

National Crane Services

3.3Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

81. TEST #1

Fixed Capacity 2,000 LB

82. TEST #2

CONFIGURATION CAPACITY LOAD APPLIED

Status

83. INSPECTION RESULTS Certified

84. REMARKS AND LIMITATIONS

Please refer to the signature page at the end of the inspection report for the "Certification Process Notice to Owner" for your scheduled maintenance responsibilities. The summary follows the signature page if any items were noted that need attention.

85. ANY LIMITATIONS No

86. REMARKS

87. REMARKS (CONTINUE)

Printed on 06/29/2024

National Crane Services

3.4Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

Summary Page Equipment Number: VGWTF-01

Recommendation: There is no warning label IAW ASME B30.16 installed on the unit. Install.

Recommendation: There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

Recommendation: There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Deficiency: Most of the buss bar mounting clip is broken. Repair.

The buss bar system is extremely dirty. Clean.

Recommendation: The pendant cord is dry rotted and cracked. Repair.

Recommendation: During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: During this inspection, there was no internal inspection of the trolley gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the trolley gearcase for internal inspection.

Deficient: The crane is deficient and should be removed from service until repairs are made.

Equipment Number: VGWTF-02

Recommendation: There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

Recommendation: There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Printed on 06/29/2024

National Crane Services

5.0Powered by INSPECTALL

EXCLUDED

http://www.inspectall.com/

Recommendation: During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: The load chain is dry and rusty. ASME B30 states that the lubricant applied shall be of the type that does not hinder the visual inspection. Lubricate.

Deficient: The crane is not connected to power at the time of inspection. It is the owner's responsibility to properly connect the crane to power and to inspect it prior to use to ensure the safe operation of the crane.

Equipment Number: VGWTF-03

Recommendation: The capacity of the monorail beam is not marked on the monorail beam. Mark.

Recommendation: There appears to be no preventative maintenance program being performed. The crane is in need of maintenance. Develop program IAW OEM specifications and initiate.

Recommendation: There is no record of a load test being performed on the crane after it was installed IAW OSHA and ASME standards. Obtain records or load test the crane IAW OSHA and ASME standards.

Recommendation: During this inspection, there was no internal inspection of the hoist gearcase. The gearcase operated adequately, but the condition of the gears and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: During this inspection, there was no internal inspection of the hoist mechanical brake. The mechanical brake operated adequately, but the condition of the discs, pawls, ratchets, and shafts is unknown. Recommend developing a program for regular oil analysis and disassembly of the hoist gearcase for internal inspection.

Recommendation: The trolley wheel spacing is not set IAW OEM specifications. Repair.

Printed on 06/29/2024

National Crane Services

5.1Powered by INSPECTALL

EXCLU

DED

http://www.inspectall.com/

Signature

As of this date, 06/28/2024, the unit(s) described in the above sheets have been found to be in this current condition. It is understood that these inspections do not preclude the necessity to perform frequent and periodic inspection in conjunction with a regular maintenance program in accordance with manufacturer's specifications and/or federal, state, and local guidelines, as applicable. These inspections do not constitute a warranty or guaranty of performance of the above equipment.

Customer Signature - Frank DeRosa

Surveyor Signature - Donald O'Rourke

Certification Process Notice to Owner Certification procedures shall not be construed as a substitute for, or cause for elimination of normal operational inspection and maintenance routine throughout the year.

The manufacturers service manual for your specific crane has specific safety and maintenance items that shall be checked daily, weekly, and monthly as a part of the owners regular maintenance program.

The owners periodic examinations shall cover, but not limited to, the following points as applicable:

1. All functional operating mechanisms shall be checked for proper function, adjustment, and excessive components wear, pay particular attention to the sheaves, pins, and drums. This shall include operation with partial load, in which all functions and movements, including, where, applicable, maximum possible rotation in both directions are performed.

2. All safety devices for proper function.

3. Deterioration or leakage in lines, tanks, valves, drains, pumps, and other parts of air or hydraulic systems.

4. Loose gear components (i.e. hooks, etc.) including wire rope and wire rope terminals and connections, pay particular attention to sections of wire rope exposed to abnormal wear and sections not normally exposed for examination. Cracked or deformed hooks shall be discarded.

5. Wire rope reeving for compliance with manufacturers recommendations.

6. Deformed, cracked, or excessively corroded members in crane structure and boom.

7. Bolts, rivets, or other connections.

8. Worn, cracked, or distorted parts affecting safe operation.

9. Excessive wear on the free operation of brake and clutch system parts, linings, pawls, and ratchets.

10. Load, boom angle, or other indicators shall be checked for accuracy.

11. The presence of a legible rating chart visible to the operator, covering the complete range of the capacity ratings at all operating radii, for all permissible boom lengths and jib lengths, with alternate ratings for operation of equipment affecting such ratings. Precautions or warnings shall be included and operating controls marked or an explanation of controls shall be posted at the operators position to indicate functions.

12. Careful examination of the junction areas of removable boom sections, particularly for proper seating, cracks, deformities, or other defects in securing bolts and in the vicinity of such bolts.

13. That the counterweights conform to manufacturers specifications.

14. Such other examinations deemed necessary under applicable circumstances.

Owner shall contact the certifying agent after important alterations and renewals and after repairs due to failure of, or damage to major components for proof testing requirements.

Members of the Crane Certification Association of America

Printed on 06/29/2024

National Crane Services

4.0Powered by INSPECTALL http://www.inspectall.com/ http://www.inspectall.com/ http://www.inspectall.com/

Venice Gardens WTP Annual Inspection - Revised.pdf
Sarasota County, Venice Gardens Water Treatment Facility Annual Inspection 06-2024.pdf
Cover Page
Table of Contents
1.0: Monorail Crane: #VGWTF-01
Annual Inspection Report

4.0: Signature Page

Pages from Sarasota County, Venice Gardens Water Treatment Facility Annual Inspection 06-2024.pdf

Pages from Venice Gardens WTP Annual Inspection - Revised.pdf
Pages from Pages from Venice Gardens WTP Annual Inspection - Revised.pdf

File details come from the government source that posted it. Updated .