VA250-17-B-0970-0003001.pdf

PDF 3 MB Posted

Attached to
Building 26 Addition
Solicitation number
VA25017B0970
Issued by

About this file

VA250-17-B-0970 0003 538-115_Addendum_02.pdf

View the file

Other files

File Type Posted
36C25018C0186-003.docx DOCX document
VA250-17-B-0970-0004001.pdf PDF
VA250-17-B-0970-0004000.docx DOCX document
VA250-17-B-0970-0003000.docx DOCX document
VA250-17-B-0970-00002000.docx DOCX document
VA250-17-B-0970-00002001.pdf PDF
VA250-17-B-0970-00001000.docx DOCX document
VA250-17-B-0970-00001001.pdf PDF
VA250-17-B-0970-021.pdf PDF
VA250-17-B-0970-019.pdf PDF
VA250-17-B-0970-020.pdf PDF
VA250-17-B-0970-025.pdf PDF
VA250-17-B-0970-022.pdf PDF
VA250-17-B-0970-016.pdf PDF
VA250-17-B-0970-024.pdf PDF
VA250-17-B-0970-017.pdf PDF
VA250-17-B-0970-018.pdf PDF
VA250-17-B-0970-023.pdf PDF
VA250-17-B-0970-015.docx DOCX document
Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DYNAMIX ENGINEERING LTD.

855 GRANDVIEW AVENUE, 3RD FLOOR

COLUMBUS, OHIO 43215

June 01, 2018

Addendum # 2

TO THE SPECIFICATIONS & DRAWINGS FOR

Correct Privacy/Safety/Environmental Issues in Building 26

Project Number: 538-115

This Document supplements and amends the original Contract Drawings and Specifications issued pursuant to Solicitation NO. VA25017B0970 and shall become a part thereof.

Item:

DRAWING REVISIONS

1.1 SHEET AS302 WALL SECTIONS

1) Delete existing SHEET AS302 WALL SECTIONS and substitute revised 30” x 42” SHEET

AS302 WALL SECTIONS attached.

1.2 SHEET AS304 EXTERIOR DETAILS

1) Delete existing SHEET AS304 EXTERIOR DETAILS and substitute revised 30” x 42” SHEET

AS304 EXTERIOR DETAILS attached.

1.3 SHEET AS402 ENLARGED TOILET ROOMS

1) Delete existing SHEET AS402 ENLARGED TOILET ROOMS and substitute revised 30” x

42” SHEET AS402 ENLARGED TOILET ROOMS attached.

1.4 SHEET AS404 ENLARGED PATIENTT TOILETS-TYPE 1C AND 1D

1) Delete existing SHEET AS404 ENLARGED PATIENTT TOILETS-TYPE 1C AND 1D and substitute revised 30” x 42” SHEET AS404 ENLARGED PATIENTT TOILETS-TYPE 1C AND 1D attached.

1.5 SHEET AS500 CASEWORK DETAILS

1) Delete existing SHEET AS500 CASEWORK DETAILS and substitute revised 30” x 42”

SHEET AS500 CASEWORK DETAILS attached.

ATTACHMENTS

Addendum Drawing AS302 WALL SECTIONS, inclusive; 30” x42”, dated June 01, 2018.

Addendum Drawing AS304 EXTERIOR DETAILS, inclusive; 30” x42”, dated June 01, 2018.

Addendum Drawing AS402 ENLARGED TOILET ROOMS, inclusive; 30” x42”, dated June

01, 2018.

Addendum Drawing AS404 ENLARGED PATIENTT TOILETS-TYPE 1C AND 1D, inclusive;

30” x42”, dated June 01, 2018.

Addendum Drawing AS500 CASEWORK DETAILS, inclusive; 30” x42”, dated June 01, 2018.

TOP OF STEEL

720' - 10 3/4"

FIRST FLOOR

710' - 0"

BASEMENT

699' - 0"

13.0

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER MOISTURE

BARRIER ON 5/8" EXT. SHEATHING ON 6" MTL.

STUDS @ 16" O.C. WITH BATT INSULATION

5/8" TYPE "X" CEMENT BOARD ON 3-5/8"

MTL STUDS @ 16" O.C. (AT BATHROOMS)

CAST STONE BELT COURSE

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON SCHEDULE CMU

FILLED WITH MASONRY FILL INSULATION

CAST STONE COPING

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON

COVERBOARD OVER TAPERED

INSULATION OVER VAPOR RETARDER

OVER SUBSTRATE BOARD

PIPE

BASEMENT

PATIENT

BATHROOM

AS304

AS304

AS304

FACE BRICK

FUTURE BASEMENT SLAB,

SHOWN FOR REFERENCE ONLY

(TYP)

TOP OF STEEL

720' - 10 3/4"

FIRST FLOOR

710' - 0"

BASEMENT

699' - 0"

13.0

ALUMINUM WINDOW

CAST STONE SILL

CAST STONE BELT COURSE

CAST STONE SILL

ALUMINUM WINDOW

PATIENT

BEDROOM

PIPE

BASEMENT

SOLID SURFACE (SSM-1) SILL

(TYP. ALL WINDOW

LOCATIONS)

5/8" TYPE "X" GYPSUM

WALLBOARD (TYP. ALL

WINDOW LOCATIONS)

SOLID SURFACE (SSM-1) SILL

(TYP. ALL WINDOW

LOCATIONS)

EXPOSED CMU (TYP. ALL PIPE

BASEMENT WINDOW

LOCATIONS)

AS304

AS304

AS304

AS304

AS304 SIM

AS304

SIM

AS304

SIM

CAST STONE COPING

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER MOISTURE BARRIER

ON 5/8" EXT. SHEATHING ON 6" MTL. STUDS @ 16" O.C.

WITH BATT INSULATION

FACE BRICK

FUTURE BASEMENT SLAB,

SHOWN FOR REFERENCE

ONLY (TYP)

TOP OF STEEL

720' - 10 3/4"

FIRST FLOOR

710' - 0"

BASEMENT

699' - 0"

26-ATTIC SLAB

734' - 2"

R.0

EXPANSION JOINT

OFFICE

PIPE

BASEMENT

EXPANSION JOINT

EXPANSION JOINT

UNO

1' - 6" TYP.

CORRIDOR

P-6B WALL TYPE

EXPOSED EXISTING

EXTERIOR WALL

AS304

SIM.

AS304

TYP

TOP OF STEEL

720' - 10 3/4"

FIRST FLOOR

710' - 0"

BASEMENT

699' - 0"

26-ATTIC SLAB

734' - 2"

E.0

ISOLATION

ROOM

CORRIDOR

PIPE

BASEMENT

EXPANSION JOINT

(TYP)

EXPANSION JOINT

(TYP)

EXPANSION JOINT

(TYP)

EXPOSED EXISTING

EXTERIOR WALL (TYP)

AS304

AS304

SIM

P6B

P6B

5/8" TYPE "X" GYPSUM WALLBOARD

ON 1 1/2" 'Z' CHANNELS (TYP) AND

1 1/2" RIGID INSULATION

TOP OF STEEL

720' - 10 3/4"

FIRST FLOOR

710' - 0"

BASEMENT

699' - 0"

26-ATTIC SLAB

734' - 2"

R.0

PATIENT

BEDROOM

QUIET

ROOM

PIPE

BASEMENT

EXPANSION JOINT

(TYP)

EXPANSION JOINT

(TYP)

EXPANSION JOINT

(TYP)

EXPOSED EXISTING

EXTERIOR WALL (TYP)

5/8" TYPE "X" GYPSUM WALLBOARD ON

1" Z FURRING CHANNELS

(TYP)

AS304

AS304

SIM

SIM

GENERAL EXTERIOR ELEVATION /

SECTION NOTES

1. REFER TO SPECIFICATIONS SECTION 08 80 00 FOR

GLAZING TYPES.

DESIGNATIONS

W-

ALUMINUM WINDOW DESIGNATION. REFER TO

SHEET AS303 FOR ADDITIONAL INFORMATION

ROBERT

BARGA

07459

S

TA

TE

OF OH

IO

R E G I S

T E RED A RC

H

I T E C

TD.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and

Facilities Management

CONSULTANTS:

© Copyright 2014

2690 W. Dublin-Granville Rd Columbus, OH 43235 p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C U s e rs

\D e s ig n L e v e L \D o c u m e n ts

\2 -B

-A rc h -C e n tr a l1

D e s ig n L e v e L -T

K .r v t

2 Addendum # 2 June 01, 2018

BID DOCUMENTS

AS302

DLLDLL

WALL SECTIONS

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUE ON BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

3/8" = 1'-0"

WALL SECTION

3/8" = 1'-0"

WALL SECTION

3/8" = 1'-0"

WALL SECTION

3/8" = 1'-0"

WALL SECTION

3/8" = 1'-0"

WALL SECTION

ALUMINUM CURTAIN WALL

ALUMINUM COUNTER FLASHING TURN UP 1/2" VERTICAL UNDER

CURTAINWALL SILL AND EXTEND 1" ONTO CONC. SET IN MASTIC BED

EXTEND ROOFING MEMBRANE UP AND FULL DEPTH OF

CURTAIN WALL SILL OVER NEOPRENE

CONC. SLAB ON COMP. MTL. DECK

SEE STR. DWGS.

STR. STL. SEE STR. DWG.

FIREPROOFING

FIRST FLOOR

710' - 0"

STAMPED CONC. SLAB SEE STR. DWGS.

BACKER ROD AND SEALANT

CONTINUOUS COMPRESSIBLE NEOPRENE

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON COVERBOARD OVER 5"

INSULATION (SLOPE TO DRAIN) OVER VAPOR BARRIER

ROOM BASE AS SCHEDULED

CURTAIN WALL WIDTH

MEMBRANE ROOFING BASE TIE-IN

(ADHERED UP WALL TURN OVER

FRONT EDGE OF 2 X PTW BLOCKING).

SEAL ALL FASTENERS

COMPRESSIBLE

FILLER

ALUMINUM

COPING BY

CURTAIN WALL

MFR.

PTW 2 X WOOD BLOCKING

SLOPE 1/4"/FT.

ALUMINUM

CURTAIN WALL

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING

MEMBRANE ON

COVERBOARD OVER

TAPERED INSULATION

OVER VAPOR RETARDER

OVER SUBSTRATE BOARD

4 1/2" 8 1/4"

BACKER

ROD & SEALANT

5/8" TYPE "X" GYPSUM WALL

BOARD ON 3 5/8" METAL

STUDS @ 16" O.C.

5/8" EXT. GRADE PLYWD SHEATHING

724' - 4"

TOP OF STEEL

720' - 10 3/4"

MOISTURE

BARRIER

ON 5/8" EXT.

SHEATHING

SAFING

INSULATION

SCHEDULED

SPANDREL

GLAZING W/

FACTORY

INSTALLED R-10

RIGID

INSULATION

STR. STL. SEE STR. DWG.

FIREPROOFING

MTL. DECK SEE STR. DWGS.

CONT. 2 X FTW (TYP.)

3 5/8" METAL STUD

@ 16" O.C.

3 5/8" METAL STUD

@ 48" O.C.

PARAPET WALL CONSTRUCTION -

SEE STR. DWG.

R-19 BATT INSULATION

SIDE CLIP PER

STR. DWG.

SEE REFLECTED

CEILING PLAN

ALUMINUM COUNTER FLASHING TURN UP 1/2" VERTICAL UNDER THRESHOLD

AND EXTEND 1" ONTO CONC. SET IN MASTIC BED

METAL THRESHOLD

STAMPED CONC. SLAB SEE STR. DWGS.

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON COVERBOARD OVER 5" INSULATION

(SLOPE TO DRAIN)

OVER VAPOR BARRIER (BELOW)

EXTEND ROOFING MEMBRANE UP AND FULL DEPTH OF THRESHOLD OVER

NEOPRENE

ALUMINUM CURTAIN WALL

/4

SEE 14/AS304 FOR ADDITIONAL INFORMATION

2 X PTW BLOCKING

CUT/SHIM AS

REQUIRED (TYP.)

5/8" TYPE "X" GYPSUM

WALL BOARD

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE

ON COVERBOARD OVER

TAPERED INSULATION OVER

VAPOR RETARDER OVER

SUBSTRATE BOARD

5/8" EXT. GRADE PLYWD

SHEATHING

PTW 2x WOOD

BLOCKING

TOP OF STEEL

720' - 10 3/4"

TYPICAL METAL STUD

CAVITY WALL

2" CAVITY WALL INSULATION

OVER MOISTURE BARRIER

ON 5/8" EXT. SHEATHING ON

6" MTL. STUDS @16" O.C.

WITH BATT INSULATION

2 HR. SAFING INSULATION ON

CONT. RETAINING CLIP

WEEP VENTS @ 36" OC

SLOPE 1/4"/FT

PIN STRIP

SEAL AROUND

PENETRATIONS IN

FLASHING W/

COMPATIBLE SEALANT

SS FLASHING

WEATHERSEAL

SIDE CLIP SEE STR. DWG.

FACE BRICK

/2

1" (TYP.)

MEMBRANE ROOFING BASE TIE-IN

(ADHERED UP WALL TURN OVER

FRONT EDGE OF 2 X PTW

BLOCKING). SEAL ALL FASTENERS

MTL. DECK

SEE STR. DWGS.

FIREPROOFING

STR. STL. SEE STR. DWG.

CAST STONE COPING

DRIP (TYP.)

COMPRESSIBLE FILLER

1-1/2" EMBED BACKER ROD AND SEALANT

TOP OF STEEL

720' - 10 3/4"

ALUMINUM

REGLET

COUNTER-

FLASHING WITH

LOCK SEAM

ALUMINUM

SPRINGLOK

FLASHING

(4" MIN. FACE)

FACE OF

EXISTING

BRICK

2 HR. FIRE

SAFING ON

CONT.

RETAINING

CLIP

MTL. DECK SEE

STR. DWGS.

CONT. 2 X

PTW (TYP.)

2 X PTW

BLOCKING

CUT/SHIM AS

REQUIRED

(TYP.)

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON

COVERBOARD OVER TAPERED INSULATION OVER

VAPOR RETARDER OVER SUBSTRATE BOARD

HOLD 2" CLEAR

EXPANSION

FILL WITH

FIBERGLASS

INSULATION

MEMBRANE

ROOFING BASE

TIE-IN

(ADHERED UP

WALL WITH

ELASTOMETRIC

BELLOWS)

M

IN

A B

O V

E H

P

O

F R

O O

F I N

S U

L A

T

IO

N

FIRE PROOFING

STR. STL. SEE

STR. DWG.

HOLD LEVEL AROUND

ROOF/EXIST. WALL

JUNCTURE

SHADED

EXISTING WALL

FIRST FLOOR

710' - 0"

CAST STONE BELT

COURSE WITH (2) #8

REBARS

DRIP

(MATCH EXISTING)

1 1/2"

CONC. SLAB ON COMP. MTL.

DECK SEE STR. DWGS.

FIREPROOFING

STR. STL. SEE STR. DWG.

FACE BRICK

(2) STRAP/PIN

ANCHOR AT JOINT

2 HR SAFING INSULATION ON

CONT. RETAINING CLIP

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION

OVER MOISTURE BARRIER

ON SCHEDULE CMU FILLED

WITH MASONRY FILL

INSULATION

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON 5/8" EXT.

SHEATHING ON 6" MTL. STUDS @ 16"

O.C. WITH BATT INSULATION

BOND BEAM - SEE STR. DWG.

FIRST FLOOR

710' - 0"

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON 5/8" EXT.

SHEATHING ON 6" MTL STUDS @ 16"

O.C. WITH BATT INSULATION

PEA GRAVEL 8" ABOVE WEEP HOLE

LAP AND ADHESIVE SEAL MOISTURE

BARRIER OVER FLASHING 1 1/2"

2 HR SAFING INSULATION ON CONT.

RETAINING CLIP

ALUMINIUM COPING TURN

UP BEHIND THROUGH WALL

FLASHING

LAP MOISTURE

BARRIER OVER 2X PTW

WEEP HOLE WICK @ 24" O.C.

THROUGH WALL FLASHING

GROUT SOLID

TURN COPING DOWN 1" IN

SAW CUT REGLET -PACK

CON'T. LEAD WEDGE

PTW WEDGE SHIM

2 X PTW

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION OVER MOISTURE

BARRIER ON SCHEDULE CMU FILLED WITH

MASONRY FILL INSULATION

BOND BEAM AND HALF

COURSE BELOW - SEE STR

DWG

FIRE PROOFING

STR. STL. SEE STR.

DWG.

CONC. SLAB ON

COMP.

MTL. DECK. SEE STR.

DWGS.

3/4"

(2) STRAP/PIN ANCHOR

AT JOINT

FACE BRICK

BRICK FACE BEYOND

SLOPE COPING 1/4"/FT

6" 1' - 2 1/2" 1' - 4"

DRIP

(MATCH EXISTING)

CAST STONE BELT

COURSE WITH (2) #8

REBARS

ALUMINIUM COPING TURN

UP EACH END BEHIND

THROUGH WALL FLASHING

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION

OVER MOISTURE BARRIER ON

SCHEDULE CMU FILLED WITH

MASONRY FILL INSULATION

BASEMENT

699' - 0"

FACE BRICK

THROUGH

WALL FLASHING

GROUT SOLID

PEA GRAVEL 8" ABOVE WEEP HOLE

WEEP HOLE WICK @24" O.C.

LAP AND ADHESIVE SEAL

MOISTURE BARRIER OVER FLASHING 1-1/2"

PERIMETER INSULATION

(2" X 2' - 0" HORIZONTAL)

FUTURE BASEMENT SLAB

ASSEMBLY (SHADED), SHOWN FOR

REFERENCE ONLY (TYP)

EXISTING WALL SYSTEM

5/8" TYPE "X" GYPSUM WALLBOARD

FIBERGLASS INSULATION FILL

WALL PARTITION TYPE P6B

FEATHER JOINT COMPOUND MIN OF 24" EACH

WAY

INTERIOR WALLBOARD EXPANSION JOINT

COVER

3/4"

COMPRESSIBLE FILLER (ADHERE TO EXIST.

CONSTRUCTION

A L

IG

N

H O

L D

E X

P A

N S

IO

N

C L E

A R

EXTERIOR EXPANSION JOINT COVER

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER MOISTURE BARRIER

ON 5/8" EXT. SHEATHING ON 6" MTL STUDS @ 16" O.C.

WITH BATT INSULATION.

FACE BRICK

HOLD 1" CLEAR EXPANSION

WITH 2 HR. FIRE SAFING ON

CON'T RETAINING CLIP

CONC. SLAB

ON COMP. MTL.

DECK SEE

STR. DWGS.

FIRE PROOFING

STR. STL. SEE

STR. DWG.

VARIES. SEE PLAN FOR

SCHEDULED WALL PARTITION.

SHADED

EXISTING WALL

FIRST FLOOR

710' - 0"

7.0

G.1

EXISTING WALL SYSTEM

AND WINDOW

1/4 "BACKER ROD AND

SEALANT (EA. SIDE)

PTW/FRTW SHIM SPACE

SPRAY APPLIED FOAM

INSULATING AIR SEAL,

SURROUND FRAME

ALUMINIUM CURTAIN WALL

1"

ALUMINUM

FLASHING BELOW

FACE BRICK

1/4" BACKER ROD AND SEALANT (EA. SIDE)

ALUMINIUM CURTAINWALL SYSTEM

5/8" TYPE "X" GYPSUM WALLBOARD

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON 5/8" EXT.

SHEATHING ON 6" MTL. STUDS @ 16" O.C.

WITH BATT INSULATION

1/4" BACKER ROD AND SEALANT

2X PTW/FRTW

PTW/ FRTW SHIM SPACE

SPRAY APPLIED FOAM INSULATION AIR

SEAL SURROUND FRAME

/4

5/8" TYPE "X" GYPSUM WALLBOARD

2X PTW/FRTW

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON 5/8" EXT.

SHEATHING ON 6" MTL. STUDS @ 16"

O.C. WITH BATT INSULATION.

X FACE BRICK

LAP ADHESIVE SEAL MOISTURE

BARRIER OVER FLASHING 1 1/2"

INTEGRAL BLIND

INSULATED GLASS UNIT

GUARDIAN SASH

PLASTIC GLAZING

ALUMINUM WINDOW SYSTEM

MATCH EXG

2 1/2" +/-

7/8"

1"

DRIP (MATCH EXISTING)

/4

/8

CAST STONE SILL

1/2" SOLID SURFACE

SILL

BACKER ROD AND

SEALANT

WALL PARTITION

AS SCHEDULED 3 1/2" X 3 1/2" X 1/4" STEEL ANGLE

SEALANT

SPRAY APPLIED FOAM INSULATION

AIRSEAL AROUND FRAME

EXISTING WALL SYSTEM

FACE BRICK

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON SCHEDULE CMU

FILLED WITH MASONRY FILL INSULATION

BACKER ROD AND SEALANT

COMPRESSIBLE FILLER (ADHERE TO EXIST.

CONSTRUCTION

H O

L D

E X

P A

N S

IO

N

C L E

A R

EXTERIOR EXPANSION JOINT COVER

3/4"

1/8"

SOLID CMU

EXISTING SITE WALL

2X PTW/FRTW

TYPICAL METAL STUD CAVITY WALL

2" CAVITY WALL INSULATION OVER

MOISTURE BARRIER ON 5/8" EXT.

SHEATHING ON 6" MTL. STUDS @ 16"

O.C. WITH BATT INSULATION.

X

THROUGH WALL FLASHING

5 1/4" 1

/8

FACE BRICK

LAP ADHESIVE SEAL MOISTURE

BARRIER OVER FLASHING 1 1/2"

PEA GRAVEL 8" ABOVE WEEP HOLE

WEEP HOLE WICK @ 24" O.C.

INTEGRAL BLIND

INSULATED GLASS UNITGUARDIAN SASH

PLASTIC GLAZING ALUMINUM WINDOW SYSTEM

MATCH EXG.

2 1/4" +/-

3 1/2" X 3 1/2" X 1/4" STEEL ANGLE

SEALANT

SPRAY APPLIED FOAM

INSULATION AIRSEAL

SURROUND FRAME

R.0

3'-5 1/4"

VIF

SHIM AS REQUIRED

TO LEVEL SILL

1/2" SOLID SURFACE

SILL (EASE THE EDGES)

EXISTING STONE

SILL TO REMAIN

SEALANT

TYPICAL CMU CAVITY WALL

2" CAVITY WALL INSULATION

OVER MOISTURE BARRIER ON

SCHEDULE CMU FILLED WITH

MASONRY FILL INSULATION

FACE BRICK

BACKER ROD

AND SEALANT

WALL PARTITION

AS SCHEDULED

1/2"

3/8"

FIRST FLOOR

710' - 0"

7.0

/4

ALUMINIUM FLASHING TURN UP TO REGLET AND

EXTEND 1" ONTO CONC. SET IN MASTIC BED

STAMPED CONC. SLAB SEE DWGS.

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON

COVERBOARD OVER 5" INSULATION OVER

VAPOR BARRIER

2 HR FIRE SAFING ON CONT. RETAINING CLIP

CONT. L SEE STR. DWG.

1/4" CONT. RIGID NEOPRENE

VARIES SEE PLAN

FOR SCHEDULED

WALL PARTITION

1/2" EMBED BACKER

ROD AND SEALANT

ALUM. REGLET

COUNTERFLASHING

WITH 1/2"

VERTICAL CRIMP

RETURN

SHADED

EXISTING WALL

CONC. SLAB ON COMP. MTL.

DECK SEE STR. DWGS.

FIREPROOFING

STR. STL. SEE STR. DWG.

HOLD 1" EXPANSION CLEAR

G.9

MEMBRANE ROOFING BASE TIE-IN

(ADHERED UP WALL TURN OVER

FRONT EDGE OF 2 X PTW BLOCKING).

SEAL ALL FASTENERS

2 X PTW

METAL COPING

PREFINISHED METAL DRIP EDGE

3/4" EXT. GRADE PLYWD

SHEATHING ON 3 5/8" METAL STUD

@ 16" O.C.

TYPICAL ROOF SYSTEM

SINGLE PLY ROOFING MEMBRANE ON

COVERBOARD OVER TAPERED INSULATION

OVER VAPOR RETARDER OVER SUBSTRATE

BOARD

ROBERT

BARGA

07459

S

TA

TE

OF OH

IO

R E G I S

T E RED A RC

H

I T E C

TD.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and

Facilities Management

CONSULTANTS:

© Copyright 2014

2690 W. Dublin-Granville Rd Columbus, OH 43235 p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C U s e rs

\D e s ig n L e v e L \D o c u m e n ts

\2 -B

-A rc h -C e n tr a l1

D e s ig n L e v e L -T

K .r v t

2 Addendum # 2 June 01, 2018

BID DOCUMENTS

AS304

DLLDLL

EXTERIOR DETAILS

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUE ON BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

1 1/2" = 1'-0"

CURTAINWALL SILL

1 1/2" = 1'-0"

CURTAINWALL PARAPET

1 1/2" = 1'-0"

CURTAINWALL SILL AT DOOR

1" = 1'-0"

PARAPET AT PATIENT ROOMS

1 1/2" = 1'-0"

ROOF FLASHING AT EXISTING

1" = 1'-0"

BELT COURSE AT PATIENT BATHROOMS

1" = 1'-0"

BELT COURSE AT PATIENT ROOMS

1" = 1'-0"

FOUNDATION & GRADING DETAIL

1" = 1'-0"

PLAN DETAIL-NEW FIRST FLOOR WALL

AT EXISTING

1 1/2" = 1'-0"

FLOOR EXPANSION JOINT AT EXISTING

EXTERIOR WALL

1 1/2" = 1'-0"

PLAN DETAIL - CURTAIN WALL @

EXISTING EXTERIOR WALL 1 1/2" = 1'-0"

PLAN DETAIL - CURTAINWALL @

BALCONY

1 1/2" = 1'-0"

TYPICAL WINDOW SILL

1" = 1'-0"

PLAN DETAIL-NEW BASEMENT WALL AT

EXISTING

1 1/2" = 1'-0"

WINDOW HEAD AT PATIENT ROOMS

1 1/2" = 1'-0"

DETAIL - TYPICAL SILL AT EXISTING

WINDOWS

1 1/2" = 1'-0"

EXT DETAIL-COURTYARD@ EXT WALL

1 1/2" = 1'-0"

TYPICAL COLUMN WRAP AT ROOF

S

G.8 G.9

TD

METAL TOP CAP

ACCENT TILE

1/2" METAL COVE

FIELD TILE

FIELD TILE

7.0 7.2

CH-1

AS604

AS604 TYP.

TYP.

METAL TOP CAP

ACCENT TILE

1/2" METAL COVE

FIELD TILE

FIELD TILE

H.0 G.9

GB-1-E TPD

METAL TOP CAP

ACCENT TILE

1/2" METAL COVE

FIELD TILE

FIELD TILE

7.07.2

GB-1-D

SD

SB2434

AS500

TYP

WALL TILE WITH

METAL TOP CAP

ACCENT TILE

1/2" METAL COVE

FIELD TILE

FIELD TILE FE

P4B

METAL TOP TRIM

TD

ACCENT TILE

FIELD TILE

FIELD TILE

1/2" METAL COVE

10.0 10.1

METAL TOP CAP

CH-1

ACCENT TILE

AS604

TYP.

AS604

TYP

(T Y

P

(T Y

P

(T Y

P

/2

1/2" METAL COVE

FIELD TILE

FIELD TILE

3' - 0"

GB-1-E

TPD

SD

METAL TOP TRIM

ACCENT TILE

FIELD TILE

FIELD TILE

1/2" METAL COVE

10.010.1

TD

M-1-A

GB-1-D

SB2434

AS500

TYP

METAL TOP CAP

ACCENT TILE

1/2" METAL COVE

FIELD TILE

FIELD TILE FE

P4B

7.0

G.8 H.0

7.2

G.9

AS4026

TD

SD

M

-1 -A

GB-1-E

G B

-1 -D

TPD

CH-1

1' - 9"

2' - 2"

"1

P8

P8

P9B

P9B

P6B P4B

P4B

P6B

P9B

P4A P4B

P9B

VISITOR

TOILET

105A

FD

1' - 0"

P8

P8

P9B

(SIM)(CEMENT BOARD)

(TYP)

7.0

G.8 H.0

7.2

G.9

VISITOR

TOILET

105A

2' - 9"

3' - 8"

8' - 0"

GWB

10.0

C.0 C.1

10.1

AS40212

M -1

-A

CH-1

G B

-1 -D

TOILET

P4B

P4B

P6B GB-1-E

TPD

SD

TD

FD 3

1' - 0" P4B

1' - 6"

/4

P9B P9B

P9B

P9B

P9B

10.0

C.1

10.1

TOILET

8' - 0"

GWB

E Q

E Q

2' - 3"

1' - 10"

FLUSH

(FL)

DOOR TYPES

FLUSH WITH

HALF GLAZED

PANEL

(FLHG)

6" 10"

FLUSH WITH

WIDE VISION

PANEL

(FLWVP)

10"6"

FLUSH WITH

FULL GLAZED

PANEL

(FLFG)

ALUMINUM

AND GLASS

(ALGL)

DOOR LEGEND

TYP.

4"

DOOR MARK

PAIR DUAL

EGRESS

PAIR

1. PLAN INDICATION

2. ALL DOORS TO BE 1 3/4" THICK, UNO

3. DOOR FRAME NOTES: ALL FRAMES TO BE DOUBLE RABITTED WITH 2" FACE AND

1/2" RETURN EACH. SEE AS4-00 FOR DETAILS.

4. LABELED, LEAD LINED DOORS WITH GLASS SHALL BE GLAZED WITH FRG AND

LEADED GLASS

NOTE: REFER TO SHEET AS400 FOR DOOR SCHEDULE

DESIGNATIONS

EXISTING TO REMAIN

NEW CONSTRUCTION

ROOM NAME

ROOM NUMBER

FLOOR PLAN CODED NOTES

VA PROVIDED, VA INSTALLED (VV) OR VA

FURNISHED, CONTRACTOR INSTALLED (VC)

EQUIPMENT/FURNISHINGS

CONTRACTOR FURNISHED,

CONTRACTOR INSTALLED (CC)

NOTE: DIMENSIONS ARE FROM FINISHED FLOOR TO BOTTOM OF VISION GLASS PANEL

8" 10"

1. MOP RECEPTOR

2. BEDSIDE TABLE - VV

3. PATIENT BED - VV

4. PATIENT CHAIR - VV

5. TASK CHAIR - VV

6. SIDE CHAIR - VV

7. WASTE RECEPTACLE - VV

8. COMPUTER WORK STATION - VV

9. WALL MOUNTED SHARPS CONTAINER -VC

10. WALL MOUNTED GLOVE BOX - VC

11. MEDICAL RAIL -VC

12. SYPHGMOMANOMETER (RAIL MOUNTED) - VV

13. EXAM TABLE - VV

14. OTOSCOPE (RAIL MOUNTED) - VV

15. PHYSICIAN STOOL - VV

16. CUSTOM VIRTUAL FIREPLACE

17. WALL MOUNTED CLOCK - SHOWN FOR COORDINATION

ONLY - COR TO PROVIDE FINAL LOCATIONS

18. COFFEE MACHINE - PLUMBED -VV

19. WALL MOUNTED TELEVISION (VV) AND BRACKET (VV)

20. PHONE (W = WALL PHONE, D = DESK PHONE)

21. OVERHEAD BIN FOR CHARTS - VC

22. WALL MOUNTED BIN SYSTEM - VC. INSTALL TOP OF

PANELS @ 72" UNO

23. MEDICATION CART - VV

24. MEDICATION DISTRIBUTION SYSTEM - VV

25. TREADMILL- VV

26. ELLIPTICAL MACHINE - VV

27. ICE MACHINE - VV

28. HOSTESS CART - VV

29. CRASH CART - VV

30. SIGNAGE - VV. REFER TO SIGNAGE SCHEDULE ON

AS705 FOR REFERENCE ONLY.

31. COILING DOOR - VV

32. LINEN CART - VV

33. SMART BOARD - VV

34. COUNTERTOP - REFER TO DETAIL12/AS500, PS-2.

35. SUPPLY CART - VV

36. SHELVING - VV

37. COMMERCIAL WASHER/DRYER COMBO - VV

38. MAGAZINE RACK - VV

39. PAMPHLET RACK - VV

40. ABA FIXED LOCKER BENCH

41. FOOD DISTRIBUTION CART - VV

42. UTILITY TUB - SEE P-SERIES DRAWINGS

43. INSTALL WINDOW FILM ON EXISTING WINDOW, A =

OPAQUE, B = 70% TRANSLUCENCY, C= OPAQUE BLACK

44. INTUMESCENT COATING AT EXPOSED COLUMNS

45. ALIGN

46. CONSTRUCT MTL. STUD TIGHT TO EXISTING COLUMN

47. ALIGN NEW TYPE "X" GYPSUM WALLBOARD WITH

FINISH FACE OF WINDOW OPENING. REFER TO

16/AS602

48. WINDOW SHADES (WS-1). MOUNT TIGHT TO WINDOW

FRAME. PROVIDE 2X6 IN WALL FRTW SURROUND FOR

HEAD/TRACK SECUREMENT.

49. MOVABLE WALL PARTITION - VV

50. FURNITURE-VV

CABINET DESIGNATIONS / ABBREVIATIONS

AG

BP

C

CB

CCT

D

DD

DF

DO

DS

ED

EP

F

FE

FV

HD

KBT

KS

MC

MF

MKBD

MW

O

OSC

PL/PLAM

PS

PTR

REF/FRZ

S

SA

SB

SC

SD

SH

SS

TD

TS

TL

TKBD

UCR

ACCESS GROMMET

BLANK PANEL

CART

COUNTERTOP BRACE

CUBICLE CURTAIN TRACK

DOOR BASE CABINET

DRAWER/DOOR BASE CABINET

DRAWER/FILE BASE CABINET

DRAWER/OPEN

DOOR(S) SLIDING

EQUAL DRAWERS

EMERGENCY POWER

FILLER PIECE 3/4" MIN - 2 1/2" MAX

FINISHED END OR FIXED EQUIPMENT

FIELD VERIFY

DOOR WALL CABINET

KEYBOARD TRAY

KNEE SPACE

MICROWAVE CABINET

MOBILE DRAWER/FILE CABINET

MARKERBOARD

MICROWAVE

OPEN FACE CABINET

OPEN SINK CABINET

PLASTIC LAMINATE

PEDESTAL SUPPORT PANEL

PRINTER

REFRIGERATOR/FREEZER

SINK

HAND SANITIZER

SINK BASE

STORAGE CABINET

SOAP DISPENSER

SHELF

STAINLESS STEEL

TOWEL DISPENSER

TACK SURFACE

TASK LIGHT

TACKBOARD

UNDER COUNTER REFRIGERATOR

W-

WINDOW DESIGNATION. REFER TO SHEET

AS303 FOR SIZE, STYLE, AND TYPE

SEE SHEET AS000 FOR OTHER LEGEND ABBREVIATIONS

LEGEND

GENERAL REFLECTED CEILING

PLAN NOTES

REFLECTED CEILING PLAN

CODED NOTES

RECESSED LIGHT FIXTURE

RECESSED LIGHT FIXTURE (EMERGENCY)

SMOKE DETECTOR

CAN LIGHT (DIAGONAL HATCH =

EMERGENCY)

1 X 4 UTILITY LIGHT

WALL MOUNTED LIGHT (DIAGONAL HATCH =

EMERGENCY)

EXIT LIGHT (WALL MOUNTED)

EXIT SIGN

SUPPLY AIR (ACOUSTIC CEILING SYSTEM)

RETURN AIR (ACOUSTIC CEILING SYSTEM)

SUPPLY/RETURN AIR (GYPSUM BOARD

CEILING SYSTEM)

NURSE CALL (WALL MOUNTED)

CAMERA (CEILING/WALL)

CUBICLE CURTAIN TRACK (CCT)

ACCESS PANEL

SPRINKLER (EXPOSED)

SPRINKLER (CONCEALED)

1. REFER TO THE MECHANICAL, ELECTRICAL, PLUMBING,

TECHNOLOGY AND FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION.

2. REFER TO THE PROJECT MANUAL FOR DETAILED

PRODUCT INFORMATION.

3. SPRINKLER HEADS IN CEILING TILES / PANELS SHALL BE

CENTERED IN THE CEILNG TILES / PANELS.

4. ALL FIXTURES AND DEVICES SHALL BE CENTERED IN

CEILING TILES / PANELS UNO.

5. THE MINIMUM CEILING TILE / PANEL IS TO BE 6" WIDE.

WHERE THIS IS NOT POSSIBLE, CONTRACTOR TO

CONSULT COR FOR CLARIFICATION.

6. LIGHTING FIXTURES ARE DIMENSIONED TO CENTER, UNO.

7. THE ARCHITECTURAL REFLECTED CEILING PLANS ARE TO

BE USED FOR COORDINATION OF ALL CEILING MOUNTED

ELEMENTS. WHERE DISCREPENCIES OCCUR BETWEEN

THE ARCHITECTURAL AND ENGINEERING DRAWINGS,

CONSULT THE COR FOR CLARIFICATION.

8. ALL CEILING GRID SYSTEMS SHALL BE CENTERED IN

ROOM EACH DIRECTION, UNO.

9. COORDINATE THE REQUIRED DIMENSIONS FOR ANY

LARGE EQUIPMENT

MATERIAL OR HEIGHT TRANSITION

SPEAKER

1. CEILING MOUNTED PROJECTOR - VV

2. GWB CEILING - COORDINATE HEIGHT WITH TOP OF

LOCKERS

SP

START GRID INDICATOR

CEILING TYPE

CEILING HEIGHT

X

X

DD2434 - FIRST TWO LETTERS-CABINET TYPE

DD2434 - FIRST TWO DIGITS-CABINET WIDTH

DD2434 - SECOND TWO DIGITS-CABINET HEIGHT

SEE MATERIAL FINISH SCHEDULE ON

AS705 FOR MATERIAL

CABINET DESIGNATIONS LEGEND

NOTE: NOT ALL CODED NOTES ARE NECESSARILY USED ON THIS SHEET.

UTILITIES LEGEND

- PANIC BUTTON

- ELECTRICAL DUPLEX

RECPTACLE

- LIGHT SWITCH

P

P

TV

NC

- TELEPHONE

- DATA

- TELEVISION CABLE

- NURSE CALL

ROBERT

BARGA

07459

S

TA

TE

OF OH

IO

R E G I S

T E RED A RC

H

I T E C

TD.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and

Facilities Management

CONSULTANTS:

© Copyright 2014

2690 W. Dublin-Granville Rd Columbus, OH 43235 p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C U s e rs

\D e s ig n L e v e L \D o c u m e n ts

\2 -B

-A rc h -C e n tr a l1

D e s ig n L e v e L -T

K .r v t

2 Addendum # 2 June 01, 2018

BID DOCUMENTS

AS402

DLLDLL

ENLARGED TOILET ROOMS

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUE ON BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

1/2" = 1'-0"

NORTH ELEVATION - TOILET

1/2" = 1'-0"

EAST ELEVATION - TOILET

1/2" = 1'-0"

SOUTH ELEVATION - TOILET

1/2" = 1'-0"

WEST ELEVATION - TOILET

1/2" = 1'-0"

NORTH ELEVATION - TOILET

1/2" = 1'-0"

EAST ELEVATION - TOILET

1/2" = 1'-0"

SOUTH ELEVATION - TOILET

1/2" = 1'-0"

WEST ELEVATION - TOILET

1/2" = 1'-0"

ENLARGED FLOOR PLAN - TOILET

1/2" = 1'-0"

ENLARGED CEILING PLAN - TOILET

1/2" = 1'-0"

ENLARGED FLOOR PLAN - TOILET

1/2" = 1'-0"

ENLARGED CEILING PLAN - TOILET

6.0

P.0 P.2

PATIENT

BATHROOM

TYPE 1C

147A

AS4046

G B

-1 -C

M -1

-B

CH-1

GB-1-E

TPD

SD

TD

SE-1GB

/8

/2

/2

5' - 4 7/8"

1' - 9 5/8"

AS604

FD

1' - 0"

P6B

P9B P4B

P6B

P7B

P4B

P9B

P9B

7' - 2 1/2"

/8

P4B

P4B

P7B

P6B

P9B

(SIM)

1' - 11 5/8" +/-5'-0" MIN. INSIDE CLEAR

IN

S

ID

E

C L E

A R

6.0

P.0 P.2

PATIENT

BATHROOM

TYPE

1C

147A

8' - 0"

GWB

8' - 4"

GWB

7' - 6"

GWB

CCT

C C

T

/2

AS602

AS602

AS602

AS602

SIM.

1 1/2"

/2

E Q

E Q

EQ EQ

E Q

E Q

1' - 10"

1' - 7"

P.0 P.2

SD

GB-1-E

TPD1/2" METAL

COVE

ACCENT TILE

FIELD TILE

FIELD TILE

METAL TOP CAP

(T Y

P

/2

(T Y

P

(T Y

P

AS604

6.0

GB-1-C

METAL TOP CAP

GB

SE-1

SD

M-1-B

TD

1/2" METAL

COVE

AS500

ACCENT TILE

AS604

TYP.

FIELD TILE

FIELD TILE

AS604

SB2434

FE

P.0P.2

CH-1

METAL TOP CAP

TD

SE-1

GB

CCT

ACCENT TILE

FIELD TILE

FIELD TILE

1/2" METAL COVE

AS604

SIM

6.0

METAL TOP CAP

OPEN

GB

SE-1

ACCENT TILE

AS604

AS604

TYP.

TYP.

1/2" METAL COVE

FIELD TILE

FIELD TILE

AS604

C.5

PATIENT

BATHROOM

TYPE

1D

128A

AS40412

P9B

P9B

P9B

P9B

SD

M -1

-B

G B

-1 -C

SE-1

GB-2

TD

GB-1-E

TPD

CH-1

P4B

P4B

P4B

P6B

7' - 3 1/8"

1' - 9 5/8" +/-

1' - 9 5/8"

/8

/4

AS604

FD

1' - 0"3

5' - 0 5/8"

P9B

IN

S

ID

E

C L E

A R

3'-0" INSIDE CLEAR

C.5

PATIENT

BATHROOM

TYPE

1D

128A

8' - 0"

GWB

7' - 0"

GWB

C C

T

CCT

ALIGN

AS602

AS602

AS602

3"

8' - 4"

GWB

AS602

EQ

EQ

1' - 10"

C.5C.1

GB-1-E

TPD

METAL TOP CAP

1/2" METAL COVE

CCT

ACCENT TILE

FIELD TILE

FIELD TILE

AS604

AS604

M-1-B

SE-1

GB-1-C

METAL TOP CAP

1/2" METAL

COVE

GB

AS500

ACCENT TILE

AS500

TYP.

FIELD TILE

FIELD TILE

FE2

C.5 C.1

TD

GB

SE-1

1/2" METAL

COVE

METAL TOP CAP

ACCENT TILE

FIELD TILE

FIELD TILE

OPEN

METAL TOP CAP

1/2" METAL

COVE

SE-1

GB

FIELD TILE

ACCENT TILE

FIELD TILE

AS604

AS604

FLUSH

(FL)

DOOR TYPES

FLUSH WITH

HALF GLAZED

PANEL

(FLHG)

6" 10"

FLUSH WITH

WIDE VISION

PANEL

(FLWVP)

10"6"

FLUSH WITH

FULL GLAZED

PANEL

(FLFG)

ALUMINUM

AND GLASS

(ALGL)

DOOR LEGEND

TYP.

4"

DOOR MARK

PAIR DUAL

EGRESS

PAIR

1. PLAN INDICATION

2. ALL DOORS TO BE 1 3/4" THICK, UNO

3. DOOR FRAME NOTES: ALL FRAMES TO BE DOUBLE RABITTED WITH 2" FACE AND

1/2" RETURN EACH. SEE AS4-00 FOR DETAILS.

4. LABELED, LEAD LINED DOORS WITH GLASS SHALL BE GLAZED WITH FRG AND

LEADED GLASS

NOTE: REFER TO SHEET AS400 FOR DOOR SCHEDULE

DESIGNATIONS

EXISTING TO REMAIN

NEW CONSTRUCTION

ROOM NAME

ROOM NUMBER

FLOOR PLAN CODED NOTES

VA PROVIDED, VA INSTALLED (VV) OR VA

FURNISHED, CONTRACTOR INSTALLED (VC)

EQUIPMENT/FURNISHINGS

CONTRACTOR FURNISHED,

CONTRACTOR INSTALLED (CC)

NOTE: DIMENSIONS ARE FROM FINISHED FLOOR TO BOTTOM OF VISION GLASS PANEL

8" 10"

1. MOP RECEPTOR

2. BEDSIDE TABLE - VV

3. PATIENT BED - VV

4. PATIENT CHAIR - VV

5. TASK CHAIR - VV

6. SIDE CHAIR - VV

7. WASTE RECEPTACLE - VV

8. COMPUTER WORK STATION - VV

9. WALL MOUNTED SHARPS CONTAINER -VC

10. WALL MOUNTED GLOVE BOX - VC

11. MEDICAL RAIL -VC

12. SYPHGMOMANOMETER (RAIL MOUNTED) - VV

13. EXAM TABLE - VV

14. OTOSCOPE (RAIL MOUNTED) - VV

15. PHYSICIAN STOOL - VV

16. CUSTOM VIRTUAL FIREPLACE

17. WALL MOUNTED CLOCK - SHOWN FOR COORDINATION

ONLY - COR TO PROVIDE FINAL LOCATIONS

18. COFFEE MACHINE - PLUMBED -VV

19. WALL MOUNTED TELEVISION (VV) AND BRACKET (VV)

20. PHONE (W = WALL PHONE, D = DESK PHONE)

21. OVERHEAD BIN FOR CHARTS - VC

22. WALL MOUNTED BIN SYSTEM - VC. INSTALL TOP OF

PANELS @ 72" UNO

23. MEDICATION CART - VV

24. MEDICATION DISTRIBUTION SYSTEM - VV

25. TREADMILL- VV

26. ELLIPTICAL MACHINE - VV

27. ICE MACHINE - VV

28. HOSTESS CART - VV

29. CRASH CART - VV

30. SIGNAGE - VV. REFER TO SIGNAGE SCHEDULE ON

AS705 FOR REFERENCE ONLY.

31. COILING DOOR - VV

32. LINEN CART - VV

33. SMART BOARD - VV

34. COUNTERTOP - REFER TO DETAIL12/AS500, PS-2.

35. SUPPLY CART - VV

36. SHELVING - VV

37. COMMERCIAL WASHER/DRYER COMBO - VV

38. MAGAZINE RACK - VV

39. PAMPHLET RACK - VV

40. ABA FIXED LOCKER BENCH

41. FOOD DISTRIBUTION CART - VV

42. UTILITY TUB - SEE P-SERIES DRAWINGS

43. INSTALL WINDOW FILM ON EXISTING WINDOW, A =

OPAQUE, B = 70% TRANSLUCENCY, C= OPAQUE BLACK

44. INTUMESCENT COATING AT EXPOSED COLUMNS

45. ALIGN

46. CONSTRUCT MTL. STUD TIGHT TO EXISTING COLUMN

47. ALIGN NEW TYPE "X" GYPSUM WALLBOARD WITH

FINISH FACE OF WINDOW OPENING. REFER TO

16/AS602

48. WINDOW SHADES (WS-1). MOUNT TIGHT TO WINDOW

FRAME. PROVIDE 2X6 IN WALL FRTW SURROUND FOR

HEAD/TRACK SECUREMENT.

49. MOVABLE WALL PARTITION - VV

50. FURNITURE-VV

CABINET DESIGNATIONS / ABBREVIATIONS

AG

BP

C

CB

CCT

D

DD

DF

DO

DS

ED

EP

F

FE

FV

HD

KBT

KS

MC

MF

MKBD

MW

O

OSC

PL/PLAM

PS

PTR

REF/FRZ

S

SA

SB

SC

SD

SH

SS

TD

TS

TL

TKBD

UCR

ACCESS GROMMET

BLANK PANEL

CART

COUNTERTOP BRACE

CUBICLE CURTAIN TRACK

DOOR BASE CABINET

DRAWER/DOOR BASE CABINET

DRAWER/FILE BASE CABINET

DRAWER/OPEN

DOOR(S) SLIDING

EQUAL DRAWERS

EMERGENCY POWER

FILLER PIECE 3/4" MIN - 2 1/2" MAX

FINISHED END OR FIXED EQUIPMENT

FIELD VERIFY

DOOR WALL CABINET

KEYBOARD TRAY

KNEE SPACE

MICROWAVE CABINET

MOBILE DRAWER/FILE CABINET

MARKERBOARD

MICROWAVE

OPEN FACE CABINET

OPEN SINK CABINET

PLASTIC LAMINATE

PEDESTAL SUPPORT PANEL

PRINTER

REFRIGERATOR/FREEZER

SINK

HAND SANITIZER

SINK BASE

STORAGE CABINET

SOAP DISPENSER

SHELF

STAINLESS STEEL

TOWEL DISPENSER

TACK SURFACE

TASK LIGHT

TACKBOARD

UNDER COUNTER REFRIGERATOR

W-

WINDOW DESIGNATION. REFER TO SHEET

AS303 FOR SIZE, STYLE, AND TYPE

SEE SHEET AS000 FOR OTHER LEGEND ABBREVIATIONS

LEGEND

GENERAL REFLECTED CEILING

PLAN NOTES

REFLECTED CEILING PLAN

CODED NOTES

RECESSED LIGHT FIXTURE

RECESSED LIGHT FIXTURE (EMERGENCY)

SMOKE DETECTOR

CAN LIGHT (DIAGONAL HATCH =

EMERGENCY)

1 X 4 UTILITY LIGHT

WALL MOUNTED LIGHT (DIAGONAL HATCH =

EMERGENCY)

EXIT LIGHT (WALL MOUNTED)

EXIT SIGN

SUPPLY AIR (ACOUSTIC CEILING SYSTEM)

RETURN AIR (ACOUSTIC CEILING SYSTEM)

SUPPLY/RETURN AIR (GYPSUM BOARD

CEILING SYSTEM)

NURSE CALL (WALL MOUNTED)

CAMERA (CEILING/WALL)

CUBICLE CURTAIN TRACK (CCT)

ACCESS PANEL

SPRINKLER (EXPOSED)

SPRINKLER (CONCEALED)

1. REFER TO THE MECHANICAL, ELECTRICAL, PLUMBING,

TECHNOLOGY AND FIRE PROTECTION DRAWINGS FOR

ADDITIONAL INFORMATION.

2. REFER TO THE PROJECT MANUAL FOR DETAILED

PRODUCT INFORMATION.

3. SPRINKLER HEADS IN CEILING TILES / PANELS SHALL BE

CENTERED IN THE CEILNG TILES / PANELS.

4. ALL FIXTURES AND DEVICES SHALL BE CENTERED IN

CEILING TILES / PANELS UNO.

5. THE MINIMUM CEILING TILE / PANEL IS TO BE 6" WIDE.

WHERE THIS IS NOT POSSIBLE, CONTRACTOR TO

CONSULT COR FOR CLARIFICATION.

6. LIGHTING FIXTURES ARE DIMENSIONED TO CENTER, UNO.

7. THE ARCHITECTURAL REFLECTED CEILING PLANS ARE TO

BE USED FOR COORDINATION OF ALL CEILING MOUNTED

ELEMENTS. WHERE DISCREPENCIES OCCUR BETWEEN

THE ARCHITECTURAL AND ENGINEERING DRAWINGS,

CONSULT THE COR FOR CLARIFICATION.

8. ALL CEILING GRID SYSTEMS SHALL BE CENTERED IN

ROOM EACH DIRECTION, UNO.

9. COORDINATE THE REQUIRED DIMENSIONS FOR ANY

LARGE EQUIPMENT

MATERIAL OR HEIGHT TRANSITION

SPEAKER

1. CEILING MOUNTED PROJECTOR - VV

2. GWB CEILING - COORDINATE HEIGHT WITH TOP OF

LOCKERS

SP

START GRID INDICATOR

CEILING TYPE

CEILING HEIGHT

X

X

DD2434 - FIRST TWO LETTERS-CABINET TYPE

DD2434 - FIRST TWO DIGITS-CABINET WIDTH

DD2434 - SECOND TWO DIGITS-CABINET HEIGHT

SEE MATERIAL FINISH SCHEDULE ON

AS705 FOR MATERIAL

CABINET DESIGNATIONS LEGEND

NOTE: NOT ALL CODED NOTES ARE NECESSARILY USED ON THIS SHEET.

UTILITIES LEGEND

- PANIC BUTTON

- ELECTRICAL DUPLEX

RECPTACLE

- LIGHT SWITCH

P

P

TV

NC

- TELEPHONE

- DATA

- TELEVISION CABLE

- NURSE CALL

ROBERT

BARGA

07459

S

TA

TE

OF OH

IO

R E G I S

T E RED A RC

H

I T E C

TD.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and

Facilities Management

CONSULTANTS:

© Copyright 2014

2690 W. Dublin-Granville Rd Columbus, OH 43235 p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C U s e rs

\D e s ig n L e v e L \D o c u m e n ts

\2 -B

-A rc h -C e n tr a l1

D e s ig n L e v e L -T

K .r v t

2 Addendum # 2 June 01, 2018

BID DOCUMENTS

AS404

DLLDLL

ENLARGED PATIENT TOILETS -

TYPE 1C AND 1D

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUE ON BUILDING 26

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

1/2" = 1'-0"

ENLARGED FLOOR PLAN - PATIENT

TOILET TYPE 1C

1/2" = 1'-0"

ENLARGED CEILING PLAN - PATIENT

TOILET TYPE 1C

1/2" = 1'-0"

NORTH ELEVATION - PATIENT

BATHROOM TYPE 1B

1/2" = 1'-0"

EAST ELEVATION - PATIENT BATHROOM

TYPE 1C

1/2" = 1'-0"

SOUTH ELEVATION - PATIENT

BATHROOM TYPE 1C

1/2" = 1'-0"

WEST ELEVATION - PATIENT BATHROOM

TYPE 1C

1/2" = 1'-0"

ENLARGED FLOOR PLAN - PATIENT

TOILET TYPE 1D

1/2" = 1'-0"

ENLARGED CEILING PLAN - PATIENT

TOILET TYPE 1D

1/2" = 1'-0"

NORTH ELEVATION

1/2" = 1'-0"

EAST ELEVATION

1/2" = 1'-0"

SOUTH ELEVATION

1/2" = 1'-0"

WEST ELEVATION

2'-1" UNO

1/2" SOLID SURFACE

COUNTERTOP

R 1/8"

R 1/8"

(2) 1/2" CONTINUOUS

PLYWOOD, TYP

NOTE:

COORDINATE SIZE

AND LOCATION

WITH OWNER

BACKSPLASH

PROVIDE REMOVABLE

GROMMET COVER.

COORDINATE 3"±

OPENING W/COVER

3 5/8" METAL

STUDS AT 16" O.C.

ACOUSTIC CEILING

5/8" TYPE "X"

GYPSUM

WALLBOARD

FACE OF CABINET

A L

IG

N W

IT

H

T O

P O

F D

O O

R F

R A

M E

T Y

P

CAB. DEPTH1"

CONTINUOUS

3/4" PLYWOOD

SUB-BASE

NOTE: REFER TO PROJECT

MANUAL FOR DETAILED

CONSTRUCTION INFORMATION

DUST PANEL

FACTORY

INSTALLED

STIFFENER OR

3/4" SOLID BACK

SCRIBE TO WALL

UNO

2' - 1"

H E

IG

H

T V

A R

IE

S

S E

E E

L E

V A

T

IO

N S

3"

ADJUSTABLE

SHELF

SOLID SURFACE

COUNTERTOP

PL-1 ALL EXPOSED

SURFACES, UNO

NOTE: REFER

TO PROJECT

MANUAL FOR

DETAILED

CONSTRUCTION

INFORMATION

FILLER TO MATCH

CABINETS

REFER TO DETAIL

1/AS500 FOR SOFFIT

CONSTRUCTION

A L

IG

N W

/T O

P O

F D

O O

R F

R A

M E

U N

O

FINISHED END

PANEL BOTH SIDES

FACTORY INSTALLED

CONTINUOUS 2" DEEP

RECESS FOR UNDER

CABINET LIGHTING. TYP.

ALL WALL CABINETS

ADJUSTABLE SHELVES:

(1) PER CABINET 2'-0" (2)

PER CABINET MORE

THAN 2'-0" H.

3 FACTORY

INSTALLED

STIFFENERS

FOR UNITS

30" H. OR HIGHER

1' - 2 1/4"

/4

S

E E

E L E

V A

T

IO

N S

H E

IG

H

T V

A R

IE

S

PL-1 ALL EXPOSED

SURFACES, UNO

SEAL AROUND GYPSUM BOARD

PENETRATION WITH JOINT

COMPOUND

SPOT WELD TO STEEL STUD

FRAMING

2" X 2" X 1/4" BRACE AT 2'-8" OC UNO

WELDED TO STRUCTURAL STEEL

STUDS. PROVIDE CONTINUOUS FRTW

ANTI-LIGATURE SHIM AT UNDER SIDE

OF COUNTERTOP AS REQUIRED

V A

R

IE

S S

E E

E L E

V A

T

IO

N S

EASE ALL

EDGES

OUTLINE OF SHELF/ SOLID SURFACE

COUNTERTOP

BACKSPLASH

PROVIDE STRUCTURAL STEEL STUDS AT 2'-8"

OC FOR BRACE SUPPORT. REFER TO PLANS

AND ELEVATIONS FOR LOCATIONS.

PAINT TO MATCH ADJACENT WALL

MTL CLEAT

3" 4"

2' - 1" , UNO

APRON WHERE

SHOWN

V A

R

IE

S S

E E

E L E

V A

T

IO

N S

OUTLINE OF SHELF/SOLID

SURFACE COUNTERTOP

BACKSPLASH

2' - 1" , UNO

APRON WHERE

SHOWN

COUNTERTOP BRACE (CB) 1 1/2" THICK PLAM PANEL SUPPORT (PS-1)

V A

R

IE

S S

E E

E L E

V A

T

IO

N S

OUTLINE OF SHELF/ SOLID

SURFACE COUNTERTOP

BACKSPLASH

2' - 1" , UNO

APRON

WHERE

SHOWN

1 1/2" THICK PLAM PANEL SUPPORT (PS-2)

UNO

1"

1' - 0" 3"

/2

NOTE: TO BE USED AT NURSE STATION

100, NURSE STATION 120, NURSE

STATION,158 AND MED ROOM 100A

NOTE: TO BE USED AT ALL LOCATIONS

WHERE INDICATED AS PS-1 IN ELEVATION

NOTE: TO BE USED AT ALL LOCATIONS

WHERE INDICATED AS PS-2 IN ELEVATION

1 1/2" PLAM (PL-1) PANEL

SUPPORT (PS-1) AT 2'-8" O.C.,

UNO

1 1/2" PLAM (PL-1) PANEL

SUPPORT (PS-2) AT 2'-8" O.C.,

UNO

CONT

SUB-BASE

FACTORY

INSTALLED

STIFFENERS

(TYP)

/4

FIXED SHELF -

PROVIDE (5)

PER CABINET

3"

1' - 6"

PL-1 ALL EXPOSED

SURFACES, UNO

GENERAL INTERIOR ARCHITECTURAL CASEWORK

NOTES

DD2434 - FIRST TWO LETTERS-CABINET TYPE

DD2434 - FIRST TWO DIGITS-CABINET WIDTH

DD2434 - SECOND TWO DIGITS-CABINET HEIGHT

SEE MATERIAL FINISH

SCHEDULE FOR MATERIAL

CABINET DESIGNATIONS LEGEND

1. CASEWORK AND INTERIOR ELEVATIONS ARE FOR DESIGN INTENT ONLY. FIELD

MEASURE ALL AREAS THAT RECEIVE CASEWORK AFTER CONSTRUCTION OF WALLS.

NOTIFY COR OF ANY DISCREPANCIES BETWEEN DRAWINGS AND FIELD CONDITIONS.

2. DO NOT SCALE THE DRAWINGS.

3. COORDINATE CASEWORK AND INTERIOR ELEVATIONS WITH MECHANICAL,

ELECTRICAL, PLUMBING, TECHNOLOGY AND FIRE PROTECTION DRAWINGS FOR

ADDITIONAL DEVICES. CONTRACTOR IS RESPONSIBLE FOR ALL DEVICES, WHETHER

SHOWN ON ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, TECHNOLOGY

OR FIRE PROTECTION DRAWINGS. BRING ANY QUESTIONS TO THE ATTENTION OF

THE COR.

4. REFER TO OTHER DRAWINGS AND PROJECT MANUAL FOR ADDITIONAL INFORMATION.

NOT ALL EQUIPMENT IS SHOWN ON THE CASEWORK DRAWINGS. COORDINATE

REQUIRED CLEARANCE DIMENSIONS FOR ALL EQUIPMENT.

5. ALL CABINETRY SHOWN HEREIN IS DESIGNED AS IF STOCK CASEWORK (WITH

MODIFICATIONS IF NOTED). CERTAIN NOTATIONS, SUCH AS "FILLER" ETC. MAY NOT BE

APPLICABLE WITH PREMIUM GRADE CASEWORK AS SPECIFIED.

6. WALL CABINETS 24" HIGH AND SHORTER SHALL HAVE ONE ADJUSTABLE SHELF. WALL

CABINETS TALLER THAN 24" SHALL HAVE TWO ADJUSTABLE SHELVES. ALL BASE

CABINETS (EXCLUDING SINK BASE) SHALL HAVE ONE ADJUSTABLE SHELF.

7. BASE CABINETS AT COUNTERTOPS DEEPER THAN STANDARD 25" SHALL HAVE

EXTENDED FINISHED ENDS. CABINET BODIES FOR DRAWER UNITS CAN REMAIN

STANDARD DEPTH. CABINET BODIES FOR DOOR OR OPEN CABINET UNITS SHALL BE

FULL DEPTH.

8. PROVIDE CONTINUOUS CLEAT ALONG COUNTERTOP BACKS AND ENDS. FASTEN

COUNTERTOP TO CLEAT AND COUNTER BRACES. DO NOT PROVIDE CLEAT AT

UNDERCOUNTER REFRIGERATORS, FREEZERS, FILE CABINETS, ETC.

9. PROVIDE 1" RADIUS, IN PLAN, AT ALL EXPOSED COUNTERTOP CORNERS. U.N.O.

10. ALL COUNTERTOPS SHALL BE 34" TO TOP A.F.F (UNO).

11. PROVIDE LOCKS FOR ALL DRAWERS AND DOORS.

12. VERIFY SIZE OF ALL GROMMETS WITH COR PRIOR TO CASEWORK FABRICATION. ALL

GROMMETS TO HAVE FINISH PIECE.

NOTE: REFER TO

PROJECT

MANUAL FOR

DETAILED

CONSTRUCTION

INFORMATION

FILLER TO MATCH

CABINETS

REFER TO DETAIL

1/AS500 FOR SOFFIT

CONSTRUCTION

A L

IG

N W

/T O

P O

F D

O O

R F

R A

M E

U N

O

FINISHED

END PANEL

BOTH SIDES

FACTORY INSTALLED

CONTINUOUS 2" DEEP

RECESS FOR UNDER

CABINET LIGHTING. TYP.

ALL WALL CABINETS.

INSTALL PLLAM ON ALL

EXPOSED FACES

3 FACTORY INSTALLED

STIFFENERS FOR UNITS

30" H. OR HIGHER

1' - 2 1/4"

/4

S

E E

E L E

V A

T

IO

N S

H E

IG

H

T V

A R

IE

S

/8

/4

PL-1 ALL EXPOSED

SURFACES, UNO

NOTE: REFER TO PROJECT MANUAL FOR

DETAILED CONSTRUCTION INFORMATION

3 FACTORY

INSTALLED

STIFFENERS FOR

UNITS 30" H OR

HIGHER

6"

T/O 7'-2"

UNO

PL-1 ON ALL

EXPOSED SIDES

POWER, DATA OR

CABLE OUTLET.

INSTALL FLUSH WITH

INSIDE FACE OF

CABINET

TELEVISION AND

WALL MOUNT (VV)

3" 3"

3' - 8"

A - SECTION

B - ELEVATION

5'-6"

UNO

6'-0"

UNO

4A

1" X SOLID WOOD

STOP, STAINED

(PERIMETER OF

OPENING)

TOP HINGED ACRYLIC

SCREEN WITH METAL TRIM

CLEAR

5"

CONTINUOUS

3/4" PLYWOOD

SUB-BASE

NOTE: REFER

TO PROJECT

MANUAL FOR

DETAILED

CONSTRUCTION

INFORMATION

FACTORY

INSTALLED

STIFFENER

OR 3/4" SOLID

BACK

H E

IG

H

T V

A R

IE

S

S E

E E

L E

V A

T

IO

N S

3"

FIXED SHELF

PL-1 ALL EXPOSED

SURFACES, UNO

LINE OF FINSHED

END BEYOND

2' - 0"

SOLID SURFACE COUNTERTOP

CONTINUOUS

3/4" PLYWOOD

SUB-BASE

NOTE: REFER

TO PROJECT

MANUAL FOR

DETAILED

CONSTRUCTION

INFORMATION

FACTORY

INSTALLED

STIFFENER OR

3/4" SOLID

BACK

SCRIBE TO WALL

UNO

2' - 1"

H E

IG

H

T V

A R

IE

S

S E

E E

L E

V A

T

IO

N S

3"

ADJUSTABLE

SHELF

SOLID SURFACE

COUNTERTOP

PL-1 ALL EXPOSED

SURFACES, UNO

CONTINUOUS

3/4" PLYWOOD

SUB-BASE

NOTE: REFER

TO PROJECT

MANUAL FOR

DETAILED

CONSTRUCTION

INFORMATION

FACTORY

INSTALLED

STIFFENER OR

3/4" SOLID

BACK

SCRIBE TO WALL

UNO

2' - 1"

H E

IG

H

T V

A R

IE

S

S E

E E

L E

V A

T

IO

N S

3"

E Q

E

Q

E Q

E

Q

SOLID SURFACE

COUNTERTOP

PL-1 ALL EXPOSED

SURFACES, UNO

11"

REFER TO PLANS

1' - 9" MIN., UNO

8"

10"

1/2" SOLID SURFACE

COUNTERTOP AND

BACKSPLASH, SSM-2

INTEGRAL SINK

INSIDE FACE OF FINISHED

END PANEL (WHERE

SHOWN). PROVIDE FULL

HEIGHT STRUCTURAL STUD

BEHIND END PANEL.

ANGLE BRACKET - INSTALL

TO INSIDE OF REMOVABLE

PANEL.

INSTALL TO WALL WITH

TAMPER PROOF

FASTENERS

ANGLE BRACKET - INSTALL

TO INSIDE OF REMOVABLE

PANEL. ROUT OUT RECESS

FOR BRACKET IN SOLID

SURFACE MATERIAL,

INSTALL WITH TAMPER

PROOF FASTENERS

4 1/4"

PL-1 ALL EXPOSED

SURFACES, UNO

FACTORY

INSTALLED

STIFFENERS

(TYP)

/4

FIXED SHELF -

PROVIDE (4)

PER CABINET

VARIES - SEE PLAN

PROVIDE FLOOR

STOP CENTER

OF DOORS

PL-1 ALL EXPOSED

SURFACES, UNO

CONTINUOUS

3/4" PLYWOOD

SUB-BASE

NOTE: REFER TO

PROJECT MANUAL

FOR DETAILED

CONSTRUCTION

INFORMATION

FACTORY

INSTALLED

STIFFENER

OR 3/4" SOLID

BACK

H E

IG

H

T V

A R

IE

S

S E

E E

L E

V A

T

IO

N S

FIXED SHELF

PL-1 ALL EXPOSED

SURFACES, UNO

LINE OF

FINSHED END

BEYOND

VARIES - SEE PLAN

3"

1' - 0"

/8

/4

/8

/4

SOLID BACK

SOLID WOOD

TOP

3 X 3 TUBE STEEL

BOLTED TO FLOOR

1 LAYER 5/8" TYPE "X"

GYPSUM WALLBOARD ON 3

5/8" METAL STUDS EA. SIDE

W/ SOUND ATTENUTATION

FRTW

ROBERT

BARGA

07459

S

TA

TE

OF OH

IO

R E G I S

T E RED A RC

H

I T E C

TD.

Drawing Title

Approved:

Project Title

Date

Location

Checked By:

Building Number

Project Number

Drawing Number

Drawn By:

Revisions: Date

ARCHITECT/ENGINEERS:

CHILLICOTHE VA MEDICAL CENTER

o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

B

A

C

D

E

F

1 2 3 4 5 6 7 9

F

E

D

C

B

A

97 8654321

Office of Construction and

Facilities Management

CONSULTANTS:

© Copyright 2014

2690 W. Dublin-Granville Rd Columbus, OH 43235 p. 614.267.6603 www.DesignLeveLarchitecture.com

DesignLeveL planning interior design architecture

C U s e rs

\D e s ig n L e v e L \D o c u m e n ts

\2 -B

-A rc h -C e n tr a l1

D e s ig n L e v e L -T

K .r v t

2 Addendum # 2 June 01, 2018

BID DOCUMENTS

AS500

DLLDLL

CASEWORK DETAILS

5/22/2017

538-115CORRECT PRIVACY/

SAFETY/ENVIRONMENTAL

ISSUE ON BUILDING 26

6" = 1'-0"

DETAIL - COUNTERTOP EDGE

3" = 1'-0"

TYPICAL ACCESS GROMMET

1 1/2" = 1'-0"

TYPICAL SOFFIT OVER CABINET

1 1/2" = 1'-0"

TYPICAL BASE CABINET -

DRAWER/DOOR

1 1/2" = 1'-0"

TYPICAL WALL CABINET

1 1/2" = 1'-0"

TYPICAL COUNTERTOP SUPPORT

1 1/2" = 1'-0"

TYPICAL TALL CABINET WITH FIXED

SHELVES

855 Grandview Avenue, 3rd Floor Columbus, OH 43215

Phone: (614) 443-1178 Fax: (614) 443-1594

Email: dynamix@dynamix-ltd.com

Facility Engineering Consultants

Engineering Ltd.

DEL # 140120

1 1/2" = 1'-0"

MICROWAVE WALL CABINET

1 1/2" = 1'-0"

WALL MOUNTED TELEVISION HOUSING

1 1/2" = 1'-0"

TYPICAL BASE CABINET - MICROWAVE /

DOOR

1 1/2" = 1'-0"

TYPICAL BASE CABINET - DOOR

1 1/2" = 1'-0"

TYPICAL BASE CABINET - EQUAL

DRAWERS

1 1/2" = 1'-0"

TYPICAL SINK BASE CABINET

1 1/2" = 1'-0"

TYPICAL TALL CABINET WITH FIXED

SHELVES W/O TOE KICK

1 1/2" = 1'-0"

NOT USED

1 1/2" = 1'-0"

TYPICAL BASE CABINET - OPEN

SHELVES

3" = 1'-0"

SECTION DETAIL - LOW WALL END

CONITION

538-115 2018-05-11 Addendum #2_0
201410-B26-AS302 - WALL SECTIONS
Sheets
AS302 - WALL SECTIONS
AS304 - EXTERIOR DETAILS
AS402 - ENLARGED TOILET ROOMS
AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
AS500 - CASEWORK DETAILS
201410-B26-AS304 - EXTERIOR DETAILS
Sheets
AS302 - WALL SECTIONS
AS304 - EXTERIOR DETAILS
AS402 - ENLARGED TOILET ROOMS
AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
AS500 - CASEWORK DETAILS
201410-B26-AS402 - ENLARGED TOILET ROOMS
Sheets
AS302 - WALL SECTIONS
AS304 - EXTERIOR DETAILS
AS402 - ENLARGED TOILET ROOMS
AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
AS500 - CASEWORK DETAILS
201410-B26-AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
Sheets
AS302 - WALL SECTIONS
AS304 - EXTERIOR DETAILS
AS402 - ENLARGED TOILET ROOMS
AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
AS500 - CASEWORK DETAILS
201410-B26-AS500 - CASEWORK DETAILS
Sheets
AS302 - WALL SECTIONS
AS304 - EXTERIOR DETAILS
AS402 - ENLARGED TOILET ROOMS
AS404 - ENLARGED PATIENT TOILETS - TYPE 1C AND 1D
AS500 - CASEWORK DETAILS