USDA Clay Center Shade Design - IFC Drawing Set - 17 Mar 22.pdf
PDF 6 MB Posted
- Attached to
- Shade Structure building Federal contract opportunity
- Solicitation number
- 12805B22R0013
About this file
This solicitation is for the construction of shade structures at a USDA facility in Clay Center, Nebraska. The contractor shall provide all labor, equipment, materials and transportation to build the shade structures according to the plans and specifications. The project magnitude is between $1,000,000 to $5,000,000. The USDA Agricultural Research Service Plains Area office is the contracting agency. The contractor must complete all required work, including plant, labor and transportation in accordance with the provided drawings and specifications for the addition of shade structures at the USDA Meat Animal Research Center Field Research Implementation and Information Delivery facility located in Clay Center, Nebraska.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| USDA Clay Center Shade Design - Bid Schedule - Updated 05-22.docx | DOCX document | |
| RFP 12805B22R0013 Updated (6).pdf | ||
| Site Visit date.docx | DOCX document | |
| 12805B22R0013 (5).pdf | ||
| RFP Terms and Conditions.docx | DOCX document | |
| Attachment 2USDA Clay Center Shade Design - IFC Specifications - 17 Mar 22.pdf | ||
| Attachment 3 SF24 Bid Bond.pdf | ||
| Attachment 1 Wage Determination NE20220080.pdf | ||
| USDA Clay Center Shade Design - Bid Schedule - SOL.docx | DOCX document | |
| Attachment 5 Pre-Award Survey Form.doc | DOC document | |
| 12805B22R0013 (2).pdf | ||
| RFP Terms and Conditions.docx | DOCX document | |
| SF24 Bid Bond.pdf | ||
| Attachment 4 Contractor Certification Regarding EMR.docx | DOCX document | |
| Attachment 6 SAM Reps and Certs Form.docx | DOCX document |
Show all 15
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT NO.:
I, AM THE COORDINATING
PROFESSIONAL ON:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
COVER SHEET
08222.006
Checker
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
Approver
US MEAT ANIMAL RESEARCH
CENTER
SHADE STRUCTURES
08222006- 0- 0 COVER SHEET
ARCHITECTURAL
A101 LOCATION 42 EAST
A102 LOCATION 42 WEST
A103 LOCATION 25
A104 LOCATION 46
A105 LOCATION 29
A106 LOCATION 14
A107 LOCATION 18
A108 LOCATION 12
A109 SHADE STRUCTURES & FENCING
GENERAL
0 COVER SHEET
STRUCTURAL
S 01 STRUCTURAL NOTES & SCHEDULES
S101 TYPICAL STRUCTURAL DETAILS
S102 STRUCTURAL DETAILS
DRAWING INDEX
SHADE STRUCTURE DESIGN
U.S. Meat Animal Research Center Roman L. Hruska Research Center Clay Center, Nebraska
CIVIL
C000 SITE ORIENTATION PLAN
GRAND
ISLAND
KEARNEY
CLAY
CENTER
LINCOLN
NEBRASKA
KANSAS
PROJECT
SITES
INTERSTATE 80
ELECTRICAL
E 101 LOCATION 25
3/17/2022
82 72
48 38
45 35
WELL 3
WELL 1
WELL 7
WELL 5
WELL 8
USDA
ISSUED FOR
CONSTRUCTION
U
S
D
A
A-E FIRM
C000
PROJECT NO.:
08222.006
NEW SUPPORT
CABLE
NEW FABRIC
SHADE
NEW FABRIC
SHADES
2 2
EXISTING
SUPPORT
COLUMNS
NEW END COLUMN
ADJACENT TO FENCE LINE
T Y
P
NEW WIDE FLANGE END
COLUMN ADJACENT TO
FENCELINE INSIDE LAST PEN
EXISTING
SUPPORT CABLE
EXISTING
CABLE POST
S102
S102
S102
S102
EXISTING
SUPPORT
COLUMNS
CABLE BRACE TO SCREW
ANCHOR FOUNDATION
EXISTING
CABLE POST
EXISTING
SUPPORT
COLUMNS
EXISTING
SUPPORT
COLUMNS
EXISTING
SUPPORT CABLE
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A101
LOCATION 42 EAST
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A101 LOCATION 42 EAST
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
5 INTERMEDIATE COLUMN ON FENCE LINE. REMOVE AND REPLACE
FENCING IN KIND AS NEEDED TO ACCOMMODATE CONSTRUCTION
6 LOCATE NEW INTERMEDIATE COLUMN UNDER EXISTING SUPPORT CABLE
ADJACENT TO FENCE LINE.
REF. NOTES ( ):X
SCALE: 1" = 30'-0"
LOCATION 42 EAST - PLAN TRUE
NORTH
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. MATCH EXISTING GRADE WITH TOP OF FOOTING (T.O.F.) ELEVATION.
D. FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ENGINEER OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION
DOCUMENTS.
F. THE CABLE SYSTEM HAS BEEN DESIGNED BASED ON A SCHEMATIC CABLE
LAYOUT AND PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CABLE SYSTEM, INCLUDING FOUNDATIONS,
TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
2 2 2
NEW WIDE FLANGE
END COLUMN
NEW SUPPORT
CABLES
NEW FABRIC
SHADES -
SEGMENT AS
REQUIRED
NEW FABRIC
SHADES
EXISITNG
SUPPORT
CABLES
EXISTING BUILDING
EXISTING
BUILDING
END COLUMN
EXISITNG
SUPPORT
CABLES
EXISTING
CABLE POST
EXISTING
CABLE POST
EXISTING
CABLE POST
EXISTING CABLE
NEW SUPPORT
CABLE
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
NEW WIDE
FLANGE END
COLUMN
NEW WIDE
FLANGE END
COLUMN
NEW WIDE
FLANGE END
COLUMN
NEW SUPPORT
CABLES
EXISTING
CABLE POST
NEW FABRIC
SHADES
NEW FABRIC
SHADES
EXISTING
CABLE POST
EXISTING
CABLE POST
EXISITNG SUPPORT
CABLES
(F.V.)
20'-0"
(F.V.)
20'-0"
20'-0"
ALIGN WITH
EXISTING ROW
S102
S102
S102
S102
ALTERNATE #1
EXISTING CABLE
85'-6" 20'-0"
4'-6" 3'-0"
RELOCATE LINE TO
NEW COLUMN
NEW WIDE FLANGE
END COLUMN
13'-6"
5 5 5 5 5 5
(F
.V
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A102
LOCATION 42 WEST
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A102 LOCATION 42 WEST
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
5 INTERMEDIATE COLUMN ON FENCE LINE. REMOVE AND REPLACE
FENCING IN KIND AS NEEDED TO ACCOMMODATE CONSTRUCTION
REF. NOTES ( ):X
SCALE: 1" = 30'-0"
LOCATION 42 WEST - PLAN
TRUE
NORTH
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. MATCH EXISTING GRADE WITH TOP OF FOOTING (T.O.F.) ELEVATION.
D. FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ENGINEER OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION
DOCUMENTS.
F. THE CABLE SYSTEM HAS BEEN DESIGNED BASED ON A SCHEMATIC CABLE
LAYOUT AND PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CABLE SYSTEM, INCLUDING FOUNDATIONS,
TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
2 2
2 2 2 2
NEW SUPPORT
CABLES
NEW FABRIC
SHADES
NEW SUPPORT
CABLES
NEW SUPPORT
CABLES
NEW FABRIC
SHADES
NEW FABRIC
SHADES
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
S102
S102
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
TYPICAL CABLE BRACE
TO SCREW ANCHOR
FOUNDATION
6'-0"15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0" 17'-6" 15'-0"11'-6"
S102
S102
S102
S102
S102
S102
77 777777
77 77 77 77
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
NEW WIDE FLANGE
END COLUMN
ADJACENT TO
FENCE LINE
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A103
LOCATION 25
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A103 LOCATION 25
SCALE: 1" = 40'-0"
LOCATION 25 - PLAN
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. MATCH EXISTING GRADE WITH TOP OF FOOTING (T.O.F.) ELEVATION.
D. FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ENGINEER OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION
DOCUMENTS.
F. THE CABLE SYSTEM HAS BEEN DESIGNED BASED ON A SCHEMATIC CABLE
LAYOUT AND PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CABLE SYSTEM, INCLUDING FOUNDATIONS,
TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
4 RELOCATE EXISTING OVERHEAD POWER LINE TO UNDERGROUND.
COORDINATE WITH UTILITY COMPANY - SEE ELECTRICAL
5 INTERMEDIATE COLUMN ON FENCE LINE. REMOVE AND REPLACE
FENCING IN KIND AS NEEDED TO ACCOMMODATE CONSTRUCTION
7 NEW END COLUMN ADJACENT TO FENCE LINE.
REF. NOTES ( ):X
TRUE
NORTH
4 3 2 1
4 3 2 1
46.A 46.B 46.C
60'-0"
30'-0" 30'-0"
46.1
46.2
46.3
46.4
A104
A1043
METAL ROOF SYSTEM
GUTTER AND DS EACH END
EXIST BUILDING
S102
46.A 46.B 46.C
46.1
46.2
46.3
46.4
60'-0"
30'-0" 30'-0"
F4.5 F5.5 F4.5
F4.0
F5.0
F4.0
F4.0
F4.0F4.0
F5.0
F4.0
.1
8°
3'-0"
T.O.F. = 1823.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.0'
T.O. PIER = 1830.5'
T.O.F. = 1823.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.5'
T.O. PIER = 1830.5'
F4.0
T.O.F. = 1824.5'
T.O. PIER = 1830.5'
T.O.F. = 1824.75'
T.O. PIER = 1830.5'
T.O.F. = 1824.75'
T.O. PIER = 1830.5'
T.O.F. = 1824.75'
T.O. PIER = 1830.5'
T.O.F. = 1824.25'
T.O. PIER = 1830.5'
S102
GUTTER AND DSGUTTER AND DS
PRE-FIN METAL
SIDING AND TRIM
100'-0"
28'-0" 36'-0" 36'-0"
12"
1/2" GUTTER AND DSGUTTER AND DS
100'-0"
30'-0" 35'-0" 35'-0"
WALL PANELS
GIRT AT BOTTOM
OF PANELS
CONC FOOTING -
SEE PLAN
GRADE
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A104
LOCATION 46
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A104 LOCATION 46
SCALE: 1" = 20'-0"
METAL BUILDING ROOF PLAN - LOCATION 46
SCALE: 1" = 20'-0"
LOCATION 46 - FOUNDATION PLAN
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND & S102 FOR FOOTING
SCHEDULE.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. TOP OF FOOTING (T.O.F.) ELEVATION IS MINIMUM 12" BELOW FINISHED
GRADE, TYPICAL U.N.O.
D. FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND NOTIFY
ENGINEER OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION
DOCUMENTS.
F. THE METAL BUILDING FOUNDATION HAS BEEN DESIGNED BASED ON A
SCHEMATIC METAL BUILDING LAYOUT AND PRELIMINARY COLUMN
REACTIONS. THE CONTRACTOR SHALL SUBMIT STAMPED/SIGNED PLANS OF
THE METAL BUILDING (INCLUDING ACTUAL COLUMN REACTIONS) TO THE
ENGINEER OF RECORD. THE ENGINEER OF RECORD SHALL VERIFY THE
ADEQUACY OF THE FOOTINGS AS SHOWN ON THE FOUNDATION PLAN BASED
ON THE ACTUAL COLUMN REACTIONS. IF REQUIRED, THE FOOTING DESIGNS
WILL BE ADJUSTED TO RESIST THE ACTUAL COLUMN REACTIONS.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
3 REMOVE AND REPLACE FENCING AS NEEDED TO ACCOMMODATE
CONSTRUCTION AND NEW COLUMNS AND FOOTINGS.
REF. NOTES ( ):X
TRUE
NORTH
TRUE
NORTH
SCALE: 3/32" = 1'-0"
LOCATION 46 - METAL BUILDING ELEVATION
SCALE: 3/32" = 1'-0"
LOCATION 46 - METAL BUILDING SECTION
PORTABLE SHADE
STRUCTURE - SEE
2/A109
PORTABLE SHADE
STRUCTURE - SEE
2/A109
PORTABLE SHADE
STRUCTURE -SEE
2/A109
PORTABLE SHADE
STRUCTURE - SEE
2/A109
CANTILEVER SHADE
STRUCTURE - CENTERED
ON EXISTING FENCE LINE -
SEE 1/A109
40'-0" TYP
T Y
P
CANTILEVER SHADE
STRUCTURE - CENTERED
ON EXISTING FENCE LINE -
SEE 1/A109
50'-0"
50'-0"
29.A
S102
S102
29.A
29.1
29.2
29.3
29.4
29.5
29.6
29.7
29.8
29.9
29.10
29.11
29.12
29.13
29.14
29.15
29.16
29.17
29.18
TYP.
TYP.
CENTER END COLUMN
ON FENCELINE
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A105
LOCATION 29
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A105 LOCATION 29
SCALE: 1" = 40'-0"
LOCATION 29 - PLAN
SCALE: 1" = 40'-0"
LOCATION 29 - FOUNDATION PLAN
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. TOP OF FOOTING (T.O.F.) ELEVATION IS MINIMUM 12" BELOW FINISHED
GRADE, TYPICAL U.N.O.
D. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
F. THE CANTILEVER SHADE STRUCTURE FOUNDATION HAS BEEN DESIGNED
BASED ON PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CANTILEVER SHADE STRUCTURE,
INCLUDING FOUNDATIONS, TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
9 REMOVE ENTIRE FENCELINE AND REPLACE WITH 7 BAR HEAVY FENCING.
SEE 3/A109 FOR MORE INFORMATION.
REF. NOTES ( ):X
TRUE
NORTH
TRUE
NORTH
" 50'-0"
50'-0"
PORTABLE SHADE
STRUCTURE - SEE
2/A109
CANTILEVER SHADE
STRUCTURE - CENTERED
ON EXISTING FENCE
LINE - SEE 1/A109
PORTABLE SHADE
STRUCTURE - SEE
2/A109
PORTABLE SHADE
STRUCTURE - SEE
2/A109
PORTABLE SHADE
STRUCTURE - SEE
2/A109
CANTILEVER SHADE
STRUCTURE - CENTERED
ON EXISTING FENCE
LINE - SEE 1/A109
S102
14.A
14.1
14.2
14.3
14.4
14.5
TYP
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A106
LOCATION 14
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A106 LOCATION 14
SCALE: 1" = 20'-0"
LOCATION 14 - PLAN
SCALE: 1" = 20'-0"
LOCATION 14 - FOUNDATION PLAN
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
3 REMOVE AND REPLACE FENCING AS NEEDED TO ACCOMMODATE
CONSTRUCTION AND NEW COLUMNS AND FOOTINGS.
REF. NOTES ( ):X
TRUE
NORTH
TRUE
NORTH
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. TOP OF FOOTING (T.O.F.) ELEVATION IS MINIMUM 12" BELOW FINISHED
GRADE, TYPICAL U.N.O.
D. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
F. THE CANTILEVER SHADE STRUCTURE FOUNDATION HAS BEEN DESIGNED
BASED ON PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CANTILEVER SHADE STRUCTURE,
INCLUDING FOUNDATIONS, TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
HOOP BARN - CENTERED IN PEN
60'-0"
S102
18.A 18.B 60'-0"
18.1
18.2
18.3
18.4
18.5
18.6
18.7
18.8
18.9
62'-0"
10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0" 10'-0"
FABRIC HOOP BARN ROOF SYSTEM
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A107
LOCATION 18
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A107 LOCATION 18
SCALE: 1" = 20'-0"
LOCATION 18 - PLAN
SCALE: 1" = 20'-0"
LOCATION 18 - FOUNDATION PLAN
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. TOP OF FOOTING (T.O.F.) ELEVATION IS MINIMUM 12" BELOW FINISHED
GRADE, TYPICAL U.N.O.
D. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
F. THE HOOP BARN STRUCTURE FOUNDATION HAS BEEN DESIGNED BASED ON
PRELIMINARY COLUMN REACTIONS. THE APPLICABLE FOUNDATION DESIGN
& DETAILS ARE PRELIMINARY AND TO BE USED FOR PRICING PURPOSES
ONLY. THE CONTRACTOR SHALL SUBMIT STAMPED/SIGNED PLANS OF THE
HOOP BARN STRUCTURE, INCLUDING FOUNDATIONS, TO THE ENGINEER OF
RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
3 REMOVE AND REPLACE FENCING AS NEEDED TO ACCOMMODATE
CONSTRUCTION AND NEW COLUMNS AND FOOTINGS.
9 REMOVE ENTIRE FENCELINE AND REPLACE WITH 7 BAR HEAVY FENCING.
SEE 3/A109 FOR MORE INFORMATION.
REF. NOTES ( ):X
TRUE
NORTH
TRUE
NORTH
SCALE: 1/8" = 1'-0"
LOCATION 18 - SECTION
SCALE: 1/8" = 1'-0"
LOCATION 18 - ELEVATION
EXISTING BUILDING STRUCTURE
100' WIDE OVERHEAD
POWER EASEMENT
50'-0"
50'-0"
CANTILEVER SHADE
STRUCTURE - SEE
1/A109
50'-0"
A108
100' WIDE OVERHEAD
POWER EASEMENT
CANTILEVER SHADE
STRUCTURE - SEE
1/A109
A108
A108
62'-6" (F.V.)
S102
12.C
12.1
12.2
12.3
12.4
12.5
12.6
12.7
TYP
EXISTING BUILDING
STRUCTURE
CENTER ON EXISTING
FENCE LINE
S102
12.B
12.1
TYP
12.2
12.3
12.4
CENTER ON EXISTING
FENCE LINE
EXISTING BUILDING
S102
12.A
12.8
12.9
12.10
12.11
TYP
EXISTING
FENCE LINE
50'-0"
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A108
LOCATION 12
08222.006
TJS
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A108 LOCATION 12
SCALE: 1" = 30'-0"
LOCATION 12 - PLAN
SCALE: 1" = 20'-0"
LOCATION 12 - EAST STRUCTURE FOUNDATION PLAN
SCALE: 1" = 20'-0"
LOCATION 12 - NORTH STRUCTURE FOUNDATION PLAN
FOUNDATION PLAN NOTES:
A. REFERENCE SHEET S01 FOR STRUCTURAL NOTES AND SCHEDULES.
B. REFERENCE SHEET S101 FOR TYPICAL FOUNDATION DETAILS NOT
NECESSARILY INDICATED ON PLAN.
C. TOP OF FOOTING (T.O.F.) ELEVATION IS MINIMUM 12" BELOW FINISHED
GRADE, TYPICAL U.N.O.
D. PAD FOOTINGS ARE REQUIRED BELOW ALL STRUCTURAL COLUMNS.
E. CONTRACTOR FIELD VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER
OF RECORD OF ANY DISCREPANCIES WITH CONSTRUCTION DOCUMENTS.
F. THE CANTILEVER SHADE STRUCTURE FOUNDATION HAS BEEN DESIGNED
BASED ON PRELIMINARY COLUMN REACTIONS. THE APPLICABLE
FOUNDATION DESIGN & DETAILS ARE PRELIMINARY AND TO BE USED FOR
PRICING PURPOSES ONLY. THE CONTRACTOR SHALL SUBMIT
STAMPED/SIGNED PLANS OF THE CANTILEVER SHADE STRUCTURE,
INCLUDING FOUNDATIONS, TO THE ENGINEER OF RECORD FOR REVIEW.
G. ALL UNDERGROUND UTILITIES WERE PROVIDED FROM DOCUMENTS
SUPPLIED OR MARKED BY THE USDA. SCHEMMER MAKES NO GUARANTEES
ON THE ACCURACY OF THE LOCATIONS OF THESE UTILITIES. THE
CONTRACTOR IS RESPONSIBLE FOR LOCATING BY NECESSARY MEANS ANY
UTILITIES THAT MAY CONFLICT WITH THE WORK.
H. ALL WELDING BURRS AND SPATTER, AND ROUGH EDGES SHALL BE GROUND
SMOOTH IN AREAS WHERE ANIMALS CAN TOUCH STRUCTURE
COMPONENTS.
1 TEMPORARY STAGING AREA, RESTORE TO ORIGINAL CONDITION AFTER
CONSTRUCTION.
2 PROTECT EXISTING UTILITIES. PROVIDE SLEEVE THROUGH FOOTING AS
REQUIRED PER TYPICAL DETAIL 2/S101.
8 CONTRACTOR SHALL BE RESPONSIBLE FOR RETAINING A LAND
SURVEYOR REGISTERED IN THE STATE OF NEBRASKA TO OBTAIN A TITLE
COMMITMENT AND ACCURATELY LOCATE THE LIMITS OF THE EXISTING
OVERHEAD ELECTRICAL LINE EASEMENT. THE CONTRACTOR SHALL
VERIFY THAT THE PROPOSED STRUCTURE IS OUTSIDE OF THE EASEMENT
LIMITS. IF ENCROACHING ON THE EASEMENT, THE CONTRACTOR SHALL
HALT WORK IN THE AREA AND NOTIFY THE OWNER AND A/E IMMEDIATELY
FOR FURTHER DIRECTION
9 REMOVE ENTIRE FENCELINE AND REPLACE WITH 7 BAR HEAVY FENCING.
SEE 3/A109 FOR MORE INFORMATION.
REF. NOTES ( ):X
TRUE
NORTH
SCALE: 1" = 20'-0"
LOCATION 12 - SOUTH STRUCTURE FOUNDATION
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U
S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:0
P
M
A109
SHADE STRUCTURES & FENCING
08222.006
Checker
Author
JSO
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 2- A109 SHADE STRUCTURES & FENCING
SCALE: 1/4" = 1'-0"
CANTILEVER SHADE STRUCTURE
SCALE: 1/4" = 1'-0"
PORTABLE SHADE STRUCTURE
• NOMINAL 40' X 40'
• 7000 LB CONCRETE BASE WITH FORKLIFT POCKETS
• SELF-STORING 70% MESH UV RESISTANT POLYETHYLENE ROOF PANELS
• RATCHET STRAP TENSION STRAPS
• 50 FOOT WIDE STRUCTURE WITH CENTER POST DESIGN
• 24 FOOT WIDE INDIVIDUAL FABRIC PANELS
• 14 FOOT EDGE CLEARANCE
• INTERWOVEN LOW DENSITY COATED HIGH DENSITY POLYEHTYLENE ROOF PANELS
• LENGTH AS SHOWN ON DRAWINGS
SCALE: 1/4" = 1'-0"
7 BAR HEAVY CONTINUOUS FENCE
• PROVIDE 7 BAR HEAVY CONTINUOUS FENCING AT ALL LOCATIONS NEEDING REPLACEMENT
• SEE TYPICAL DETAILS 4/S101 FOR TYPICAL FENCE POST FOOTING
• ATTACH FENCE DIRECTLY TO CONCRETE OR STEEL AT NEW STRUCTURE LOCATIONS
WHERE STRUCTURE FOOTINGS PREVENT FENCELINE FOOTINGS FROM BEING INSTALLED
• PROVIDE 3"Ø STEEL POSTS AT MAXIMUM 8'-0" O.C. ALONG LENGTH OF FENCE
• PROVIDE 6"Ø STEEL POSTS AT CORNER AND GATE LOCATIONS
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:1
P
M
S 01
STRUCTURAL NOTES & SCHEDULES
08222.006
KMW
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 3- S 01 STRUCTURAL NOTES & SCHEDULES
APPLICABLE CODES AND STANDARDS
1. 2018 INTERNATIONAL BUILDING CODE
2. ACI 318-14 - BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE
3. TAISC 360-16 - SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS
4. AISI S100-16 - NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-
FORMED STEEL STRUCTURAL MEMBERS
DESIGN CRITERIA
ROOF LIVE LOAD PSF
1. ROOF LIVE LOAD (MINIMUM, NON-REDUCIBLE) 20
ROOF SNOW LOAD
1. GROUND SNOW LOAD (Pg): 25 PSF
2. FLAT-ROOF SNOW LOAD (Pf): 20 PSF
3. DRIFT SNOW LOAD PER ASCE 7-16
4. SNOW EXPOSURE FACTOR (Ce): 0.9
5. SNOW LOAD IMPORTANCE FACTOR (I): 0.8
6. THERMAL FACTOR (Ct): 1.2
WIND DESIGN DATA
1. ULTIMATE DESIGN WIND SPEED (Vult): 115 MPH
2. NOMINAL DESIGN WIND SPEED (Vasd): 90 MPH
3. RISK CATEGORY: I
4. WIND EXPOSURE: CATEGORY C
5. INTERNAL PRESSURE COEFFICIENT (GCpi): +/-0.18
6. COMPONENTS AND CLADDING DESIGN WIND PRESSURE:
A. ROOF - ZONE 1 21.04 PSF
B. ROOF - ZONE 2 17.54 PSF
C. ROOF - ZONE 3 17.54 PSF
EARTHQUAKE DESIGN DATA
1. SEISMIC IMPORTANCE FACTOR (I): 1.0
2. RISK CATEGORY: II
3. 0.2 SEC SPECTRAL RESPONSE ACCELERATION (SS): 0.0967
4. 1.0 SEC SPECTRAL RESPONSE ACCELERATION (S1): 0.0427
5. SITE CLASS: D
6. 0.2 SEC SPECTRAL RESPONSE COEFFICIENT (SDS): 0.103
7. 1.0 SEC SPECTRAL RESPONSE COEFFICIENT (SD1): 0.068
8. SEISMIC DESIGN CATEGORY: B
9. BASIC SEISMIC-FORCE-RESISTING SYSTEM:
A. STEEL MOMENT FRAMES
B. STEEL BRACED FRAMES
C. CANTILEVERED STEEL COLUMNS
10. DESIGN BASE SHEAR (V): VARIES
11. SEISMIC RESPONSE COEFFICIENT (CS): 0.0825
12. RESPONSE MODIFICATION FACTOR (R): VARIES
13. ANALYSIS PROCEDURE USED:
A. EQUIVALENT LATERAL FORCE PROCEDURE
STRUCTURAL NOTES
1. ALL WORK SHALL CONFORM TO THE REQUIREMENTS OF THE APPLICABLE
BUILDING CODE.
2. THE STRUCTURE HAS BEEN DESIGNED TO RESIST DESIGN LOADS ONLY AS
A COMPLETED STRUCTURE
A. APPLICATION OF ANY LOADS TO THE PARTIALLY COMPLETED
STRUCTURE SHALL BE CONSIDERED BY THE CONTRACTOR AND SO
INCLUDED IN THE DESIGN OF THE SHORING, BRACING, FORMWORK,
AND ANY OTHER SUPPORTING ELEMENTS PROVIDED FOR
CONSTRUCTION OF THE STRUCTURE.
B. WHERE CONSTRUCTION MATERIAL AND EQUIPMENT ARE TEMPORARILY
STORED ON THE ROOF OR FLOOR FRAMING, THEY SHALL BE
DISTRIBUTED SO THAT THE DESIGN LIVE LOAD AT THE LOADED AREA IS
NOT EXCEEDED.
C. DO NOT BACKFILL AGAINST WALLS OR OTHER STRUCTURAL ELEMENTS
UNTIL SUCH ELEMENTS HAVE REACHED THEIR INTENDED STRENGTH,
HAVE BEEN ADEQUATELY BRACED, AND/OR HAVE OTHER INTEGRAL
STRUCTURAL ELEMENTS IN PLACE WHICH ARE INTENDED TO RESIST
THE LATERAL EARTH LOADS.
3. DETAILS ON THE DRAWINGS INDICATED AS "TYPICAL" APPLY IN ALL AREAS
WHERE CONDITIONS SIMILAR TO THE DETAIL OCCUR.
4. THE STRUCTURAL DRAWINGS ARE NOT INTENDED FOR USE AS SHOP
ERECTION DRAWINGS. REPRODUCTION OF THESE DRAWINGS IN LIEU OF
PREPARATION OF SHOP ERECTION DRAWINGS SIGNIFIES THE USERS'
ACCEPTANCE THAT ALL INFORMATION SHOWN IS CORRECT AND
APPROPRIATE FOR SHOP DRAWINGS AND THAT THE USER WILL BE FULLY
RESPONSIBLE FOR EXPENSES THAT MAY OCCUR FROM SAID ACCEPTANCE.
5. UNLESS SPECIFICALLY NOTED, THERE ARE NO PROVISIONS MADE FOR
FUTURE FLOORS, ROOFS, OR OTHER LOADS.
MATERIAL DATA
CONCRETE AND REINFORCING
1. CONCRETE STRENGTH (f'c @ 28 DAYS)
A. FOOTINGS 3,000 PSI
B. COLUMNS 5,000 PSI
C. CONCRETE NOT SPECIFIED 3,000 PSI
2. ALL CONCRETE EXPOSED TO FREEZE-THAW CONDITIONS SHALL HAVE A
MINIMUM STRENGTH (f'c @ 28 DAYS) OF 4,500 PSI. THIS DOES NOT INCLUDE
FOOTINGS/GRADE BEAMS THAT ARE COVERED BY SOIL.
3. CEMENT TYPE: PORTLAND TYPE I
4. AGGREGATES
A. NORMAL WEIGHT, 1 1/2" MAX. SIZE - ASTM C33
B. PROVIDE AGGREGATES FREE OF MATERIALS WITH DELETERIOUS
REACTIVITY TO ALKALI IN CEMENT, FROM A SINGLE SOURCE WITH
DOCUMENTED SERVICE RECORD DATA OF AT LEAST 10 YEARS
SATISFACTORY SERVICE IN SIMILAR APPLICATIONS AND SERVICE
CONDITIONS USING SIMILAR AGGREGATES AND CEMENTITIOUS
MATERIALS.
5. REINFORCING STEEL ASTM A615, GRADE 60
6. REINFORCING STEEL ASTM A706, WELDABLE
7. WELDED WIRE FABRIC ASTM A185
8. PREFORMED EXPANSION JOINT (1/2") ASTM D1751
STEEL
1. STRUCTURAL STEEL (WIDE FLANGES) ASTM A992, GRADE 50
2. STRUCTURAL STEEL (ALL OTHER TYPES) ASTM A36
3. STRUCTURAL STEEL PIPE ASTM A53, GRADE B,
SCH. 40
4. STRUCTURAL TUBE ASTM A500, GRADE C
5. ANCHOR RODS ASTM F1554, GRADE 55
WITH WELDING
SUPPLEMENT S1
6. BOLTED CONNECTIONS ASTM F3125, GRADE A325N
7. WELDED CONNECTIONS E70XX ELECTRODES
8. WELDED CONNECTIONS (GALVANIZED) E6010 OR E6011
ELECTRODES
9. HEADED CONCRETE ANCHORS (HCA) ASTM A108 GRADES
C1010 THROUGH C1020
(Fu=55 KSI)
10. DEFORMED BAR ANCHORS (DBA) ASTM A108 & A496
(Fy=70 KSI)
11. METAL DECKING ASTM A611 OR
ASTM A653-94
12. LIGHT GAUGE STEEL STUDS/JOISTS
A. 12 TO 16 GAUGE (G60 GALV.) ASTM A1003 GRADE ST50H
(Fy=50 KSI)
B. 18+ GAUGE (G60 GALV.) ASTM A1003 GRADE ST33H
(Fy=33 KSI)
COORDINATION/VERIFICATION
1. CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND EXISTING
CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ENGINEER BEFORE
PROCEEDING WITH ANY PHASE OF THE WORK.
2. ANY PROPRIETARY STRUCTURAL SYSTEMS THAT ARE COMPOSED OF
COMPONENTS TO BE FIELD ERECTED SHALL BE SUPERVISED BY THE
SUPPLIER DURING MANUFACTURING, DELIVERY, HANDLING, STORAGE, AND
ERECTION IN ACCORDANCE WITH THE INSTRUCTIONS PREPARED BY THE
SUPPLIER.
GEOTECHNICAL
1. BASIS OF DESIGN: THE FOUNDATION SYSTEM DESIGN IS BASED ON THE
RECOMMENDATIONS OF GEOTECHNICAL REPORT NO. 08222.006 DATED
1/20/2022 PREPARED BY SCHEMMER.
2. FOUNDATION SYSTEM: SHALLOW FOOTINGS
3. MAXIMUM ALLOWABLE SOIL BEARING CAPACITY
A. AREA 25 3,000 PSF
B. AREA 42 2,500 PSF
C. AREA 46 3,500 PSF
D. AREA 29 2,000 PSF
E. AREA 18 2,500 PSF
F. AREA 14 2,500 PSF
G. AREA 12 2,500 PSF
4. LATERAL EARTH PRESSURE:
A. PASSIVE RESISTANCE 180 PCF
B. ACTIVE PRESSURE 50 PCF
C. AT-REST PRESSURE 65 PCF
5. SUBGRADE PREPARATION:
A. HEAVILY ORGANIC OR ROOT INFESTED TOPSOIL SHALL BE EXCAVATED
AND DISCARDED OR STOCKPILED FOR LATER USE IN COVERING
FINISHED LANDSCAPED AREAS AFTER CONSTRUCTION. REMOVE
TOPSOIL TO A MINIMUM DEPTH OF 8 INCHES. DEEPER STRIPPING SHALL
BE DONE IF ORGANIC MATERIALS REMAIN BELOW A DEPTH OF 8
INCHES.
B. REMOVE ALL EXISTING STRUCTURES TO BE DEMOLISHED PRIOR TO
GRADING. THIS INCLUDES PAVING, SIDEWALKS, AND OTHER
MISCELLANEOUS SMALL STRUCTURES.
6. STRUCTURAL FILL REQUIREMENTS:
A. CLEAN, INORGANIC, LOW TO MEDIUM PLASTICITY LEAN CLAY (CL) OR
SILT (ML), OR A COMBINATION OF THESE TWO MATERIALS
B. MAXIMUM LIQUID LIMIT (LL) 45
C. MAXIMUM PLASTICITY INDEX 22
D. WATER CONTENT (% OF OPTIMUM) +/-3%
E. MAXIMUM LOOSE LIFT 8"
F. MINIMUM COMPACTION 95% (STANDARD
PROCTOR TEST
ASTM D-698)
7. SPREAD FOOTINGS SHALL BE PLACED ON NEAT, CLEAN AND DRY
EXCAVATIONS. EXTREME CARE SHALL BE TAKEN WHEN EXCAVATING NEAR
THE BEARING SURFACE. FOOT TRAFFIC SHALL BE KEPT TO A MINIMUM
NECESSARY TO PLACE THE FOOTING REINFORCEMENT AND CONCRETE.
8. CONTRACTOR SHALL PROVIDE FOR ADEQUATE DRAINAGE OF SURFACE
WATER AWAY FROM THE STRUCTURE AND EXCAVATED AREAS DURING
CONSTRUCTION. THIS INCLUDES NECESSARY PUMPING, TRENCHING,
BACKFILL AND/OR DIKE CONSTRUCTION.
9. GRANULAR SUBBASE UNDER SLAB ON GRADE:
A. MINIMUM THICKNESS SEE PLAN
B. MINIMUM COMPACTION 95% (STANDARD
PROCTOR TEST
ASTM D-698)
C. GRADATION REQUIREMENTS
a. 100% PASSING THE 3/4" SIEVE
b. LESS THAN 15% PASSING THE 100 SIEVE
c. LESS THAN 2% PASSING THE 200 SIEVE
CAST-IN-PLACE CONCRETE
(REFERENCE SPECIFICATION SECTION 033000 IN PROJECT MANUAL)
GENERAL CONCRETE REQUIREMENTS
1. CONCRETE BATCH DESIGN(S) SHALL BE PROPORTIONED AND PRODUCED IN
ACCORDANCE WITH ACI 318, IN PARTICULAR CHAPTER 5, AND ACI 301. MIX
AND DELIVER IN ACCORDANCE WITH ASTM C94.
2. CONCRETE STRENGTH: SEE MATERIAL DATA NOTES & SPECIFICATION
SECTION 033000
3. SLUMP LIMITS: SEE SPECIFICATION SECTION 033000
4. MAXIMUM W/C RATIO: SEE SPECIFICATION SECTION 033000
5. AIR ENTRAINMENT: SEE SPECIFICATION SECTION 033000
6. ADMIXTURES: SEE SPECIFICATION SECTION 033000
7. FLY ASH: SEE SPECIFICATION SECTION 033000
8. CONCRETE TO CONCRETE COLD JOINTS - PROVIDE 1/4" INTENTIONALLY
ROUGHENED SURFACE AT ALL HORIZONTAL JOINTS.
9. EXPOSED CORNERS: PROVIDE A 3/4" CHAMFER AT ALL EXPOSED
CONCRETE CORNERS.
10. CURING: SEE SPECIFICATION SECTION 033000
11. REINFORCING BAR WELDING: ABSOLUTELY NO WELDING OF REINFORCING
BARS OR TORCHING TO BEND REINFORCING BARS SHALL BE ALLOWED
WITHOUT THE SPECIFIC APPROVAL OF THE ENGINEER.
12. MINIMUM CONCRETE CLEAR COVER:
A. FOOTINGS
a. TOP 2"
b. BOTTOM 3"
c. SIDES 3"
B. OTHER COVER REQUIREMENTS SHALL BE AS NOTED IN APPLICABLE
DETAILS.
13. NON-METALLIC, SHRINKAGE-RESISTANT GROUT: SEE SPECIFICATION
SECTION 051200
ANCHORAGE REQUIREMENTS
1. HEADED CONCRETE ANCHORS (HCA): AUTOMATICALLY END WELDED IN THE
SHOP OR FIELD IN ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS. ANCHOR WELDS SHALL BE TESTED PER AWS
SECTION 7.7.
2. POST-INSTALLED MECHANICAL ANCHORS: INSTALL USING MINIMUM
TORQUE, EMBEDMENTS, EDGE DISTANCES AND SPACING (UNLESS
OTHERWISE NOTED) AS RECOMMENDED BY THE ANCHOR MANUFACTURER.
3. POST-INSTALLED ADHESIVE ANCHORS: INSTALLATION TO MEET
MANUFACTURER'S RECOMMENDATIONS (UNLESS NOTED OTHERWISE)
INCLUDING MINIMUM EMBEDMENTS, EDGE DISTANCES, SPACING,
PROCEDURES, AND CURING TIME PRIOR TO LOADING.
4. POST-INSTALLED ANCHORS SHALL BE LOCATED PER THE DETAILS.
5. AVOID CUTTING OR DAMAGING EXISTING REINFORCING. SHOULD
LOCATIONS OF DRILLED HOLES BE FOUND DIRECTLY ALIGNED WITH
REINFORCING BARS, NOTIFY ENGINEER FOR NECESSARY ADJUSTMENTS TO
THE DESIGN.
SPECIAL INSPECTIONS (IBC 2018)
SPECIAL INSPECTIONS SHALL BE PROVIDED BY THE OWNER FOR THE WORK IN
ACCORDANCE WITH IBC CHAPTER 17. CONTRACTOR SHALL NOTIFY AND
ACCOMMODATE THE APPLICABLE INSPECTOR DURING APPROPRIATE PHASES
OF THE WORK AS REQUIRED FOR EACH TYPE OF INSPECTION.
STEEL CONSTRUCTION - GENERAL
1. SHOP CUT AND FINISHED SURFACES IN ACCORDANCE WITH SECTION M2 OF
AISC 360-16.
2. SHOP HEATING FOR STRAIGHTENING, CAMBERING AND CURVING IN
ACCORDANCE WITH SECTION M2.1 OF AISC 360-16.
3. TOLERANCES FOR SHOP FABRICATION IN ACCORDANCE WITH SECTION 6.4
OF AISC 303-16.
4. STEEL DECK IN ACCORDANCE WITH SDI-QA/QC-2017
5. FIELD CUT SURFACES IN ACCORDANCE WITH SECTION M2.2 OF AISC 360-16.
6. FIELD HEATING FOR STRAIGHTENING IN ACCORDANCE WITH SECTION M2.1
OF AISC 360-16.
7. TOLERANCES FOR FIELD ERECTION IN ACCORDANCE WITH SECTION 7.13 OF
AISC 303-16.
STEEL INSPECTION DEFINITIONS
O - OBSERVE THESE ITEMS ON A RANDOM BASIS. OPERATIONS NEED NOT
BE DELAYED PENDING THESE INSPECTIONS.
P - PERFORM THESE TASKS FOR EACH WELDED JOINT OR MEMBER, EACH
BOLTED CONNECTION, OR EACH STEEL ELEMENT.
STEEL CONSTRUCTIION - PRIOR TO WELDING
1. WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS
(QC - P; QA - O)
2. WELDING PROCEDURE SPECIFICATIONS (WPSs) AVAILABLE.
(QC - P; QA - P)
3. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES
AVAILABLE. (QC - P; QA - P)
4. MATERIAL IDENTIFICATION (TYPE/GRADE). (QC - O; QA - O)
5. WELDER IDENTIFICATION SYSTEM. (QC - O; QA - O)
6. FIT-UP GROOVE WELDS (INCLUDING JOINT GEOMETRY). (QC - O; QA - O)
A. JOINT PREPARATION.
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL).
C. CLEANLINESS (CONDITION OF STEEL SURFACES).
D. TACKING (TACK WELD QUALITY AND LOCATION).
E. BACKING TYPE AND FIT (IF APPLICABLE).
7. FIT-UP OF CJP GROOVE WELDS OF HSS T-, Y- AND K-JOINTS WITHOUT
BACKING (INCLUDING JOINT GEOMETRY) (QC - P; QA - O)
A. JOINT PREPARATION.
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL).
C. CLEANLINESS (CONDITION OF STEEL SURFACES).
D. TACKING (TACK WELD QUALITY AND LOCATION).
8. CONFIGURATION AND FINISH OF ACCESS HOLES. (QC - O; QA - O)
9. FIT-UP FILLET WELDS. (QC - O; QA - O)
A. DIMENSIONS (ALIGNMENT, GAPS AT ROOT).
B. CLEANLINESS (CONDITION OF STEEL SURFACES).
C. TACKING (TACK WELD QUALITY AND LOCATION).
10. CHECK WELDING EQUIPMENT. (QC - O; QA - N/A)
STEEL CONSTRUCTION - DURING WELDING
1. USE OF QUALIFIED WELDERS. (QC - O; QA - O)
2. CONTROL AND HANDLING OF WELDING CONSUMABLES. (QC - O; QA - O)
A. PACKAGING.
B. EXPOSURE CONTROL.
3. NO WELDING OVER CRACKED TACK WELDS. (QC - O; QA - O)
4. ENVIRONMENTAL CONDITIONS.
A. WIND SPEED WITHIN LIMITS.
B. PRECIPITATION AND TEMPERATURE.
5. WPS FOLLOWED. (QC - O; QA - O)
A. SETTINGS ON WELDING EQUIPMENT.
B. TRAVEL SPEED.
C. SELECTING WELDING MATERIALS.
D. SHIELDING GAS TYPE/FLOW RATE.
E. PREHEAT APPLIED.
F. INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.).
G. PROPER POSITION (F, V, H, OH).
6. WELDING TECHNIQUES. (QC - O; QA - O)
A. INTERPASS AND FINAL CLEANING.
B. EACH PASS WITH PROFILE LIMITATIONS.
C. EACH PASS MEETS QUALITY REQUIREMENTS.
7. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
(QC - P; QA - P)
STEEL CONSTRUCTION - AFTER WELDING
1. WELDS CLEANED. (QC - O; QA - O)
2. SIZE, LENGTH AND LOCATION OF WELDS. (QC - P; QA - P)
3. WELD MEET VISUAL ACCEPTANCE CRITERIA. (QC - P; QA - P)
A. CRACK PROHIBITION.
B. WELD/BASE-METAL FUSION.
C. CRATER CROSS SECTION.
D. WELD PROFILES.
E. WELD SIZE.
F. UNDERCUT.
G. POROSITY.
4. ARC STRIKES. (QC - P; QA - P)
5. K-AREA. (QC - P; QA - P)
6. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY
SHAPES. (QC - P; QA - P)
7. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED).
8. REPAIR ACTIVITIES. (QC - P; QA - P)
9. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER.
(QC - P; QA - P)
10. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF
THE EOR. (QC - O; QA - O)
STEEL CONSTRUCTION - PRIOR TO BOLTING
1. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS.
(QC - O; QA - P)
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS.
(QC - O; QA - O)
3. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE,
BOLT LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE).
(QC - O; QA - O)
4. CORRECT BOLTING PROCEDURE SELECTOR FOR JOINT DETAIL.
(QC - O; QA - O)
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE
CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE
REQUIREMENTS. (QC - O; QA - O)
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL
OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS
USED. (QC - P; QA - O)
7. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND
OTHER FASTENER COMPONENTS. (QC - O; QA - O)
SPECIAL INSPECTIONS CONTINUED (IBC 2018)
STEEL CONSTRUCTION - DURING BOLTING
1. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS ARE
POSITIONED AS REQUIRED. (QC - O; QA - O)
2. JOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE
PRETENSIONING OPERATION. (QC - O; QA - O)
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM
ROTATING. (QC - O; QA - O)
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC
SPECIFICATION, PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID
POINT TOWARD THE FREE EDGES. (QC - O; QA - O)
STEEL CONSTRUCTION - AFTER BOLTING
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS.
(QC - P; QA - P)
COLD-FORMED STEEL DECK
1. SPECIAL INSPECTIONS AND QUALIFICATION OF WELDING SPECIAL
INSPECTORS FOR COLD-FORMED STEEL FLOOR AND ROOF DECK SHALL BE
IN ACCORDANCE WITH THE QUALITY ASSURANCE INSPECTION
REQUIREMENTS OF SDI-QA/QC-2017.
CONCRETE CONSTRUCTION
1. INSPECTION OF REINFORCEMENT AND VERIFY PLACEMENT. (PERIODIC)
2. REINFORCING BAR WELDING:
A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706.
(PERIODIC)
B. INSPECT SINGLE-PASS FIILLET WELDS, MAXIMUM 5/16". (PERIODIC)
C. INSPECT ALL OTHER WELDS. (CONTINUOUS)
3. INSPECT ANCHORS CAST IN CONCRETE. (PERIODIC)
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE MEMBERS.
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY
INCLINED ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS.
(CONTINUOUS)
B. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4.A.
(PERIODIC)
5. VERIFY USE OF REQUIRED DESIGN MIX. (PERIODIC)
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH
TESTS, PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE
TEMPERATURE OF THE CONCRETE. (CONTINUOUS)
7. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND
TECHNIQUES. (PERIODIC)
8. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS. (PERIODIC)
9. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF THE
CONCRETE MEMBER BEING FORMED. (PERIODIC)
SOILS
1. VERIFY MATERIALS BELOW SHALLOW FOOTINGS ARE ADEQUATE TO
ACHIEVE THE DESIGN BEARING CAPACITY. (PERIODIC)
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND HAVE
REACHED PROPER MATERIAL. (PERIODIC)
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
(PERIODIC)
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES
DURING PLACEMENT AND COMPACTION OF COMPACTED FILL.
(CONTINUOUS)
5. PRIOR TO PLACEMENT OF COMPACTED FILL, OBSERVE SUBGRADE AND
VERIFY THAT SITE HAS BEEN PREPARED PROPERLY. (PERIODIC)
EL. = MATCH EXISTING
FIN. GRADE
STANDARD BEND
D = 6d #3 THRU #7 D = 8d #8 THRU #9 D = 10d #10 THRU #11 d = BAR DIAMETER
STANDARD HOOK
TYPICAL CLOSED TIE
TYPICAL LAP SPLICE
2 1/2" MIN.
6d d
D d
6d b (2'-0" MIN.) WIRED TOGETHER
TABLE APPLIES TO CIP CONCRETE
SPLICE LENGTH IS FOR TYPE B SPLICES PER ACI 318.
BARS ARE ASSUMED TO BE TOP BARS & NOT EPOXY COATED.
f'c = 3,000 PSI (NORMAL WEIGHT) BAR COVER > db fy = 60,000 PSI db = BAR DIAMETER
TENSION BAR LAP LENGTH (b)
(FOR LENGTH b - SEE REINF. BAR DETAIL AND KEY NOTES)
BAR SIZE BARS SPACED > 2db BARS SPACED < 2db
(OTHER)
28"
37"
46"
56"
81"
93"
105"
118"
131"
42"
56"
70"
83"
122"
139"
157"
176"
196"
M
A X
M
IN
MIN.
6"
M
IN
PIPE
CONDITION NO. 1
CONDITION NO. 3
PIPE SLEEVE AS SPECIFIED
CONDITION NO. 2
LEAN CONCRETE TO BE PLACED
BEFORE FOOTING - MAKE SAME
WIDTH AS FOOTING AND FULL
WIDTH OF PIPE TRENCH
WHERE PIPE IS LAID
BELOW THE 2:1 SLOPE
LINE, FILL PIPE TRENCH
W/ LEAN CONCRETE TO
SLOPE LINE
NOTES:
THIS DETAIL COVERS THREE POSSIBLE CONDITIONS THAT MAY OCCUR
AND ARE DESCRIBED AS FOLLOWS:
CONDITION NO. 1: PIPE PASSING THROUGH FOOTING.
CONDITION NO. 2: PIPE PASSING PERPENDICULAR BENEATH FOOTING.
CONDITION NO. 3: PIPE RUNNING PARALLEL TO FOOTINGS.
DIA.
(IN.)
MIN. L (IN.)
U.N.O.
3/4
12 L
/2
ANCHOR ROD
1 1/8 14
7/8 10
A563 HEAVY
HEX NUTS
TACK WELDED
F436 FLAT
WASHER
1 1/4 16
1 3/8 18
1 1/2 20
CENTERLINE OF POST =
CENTERLINE OF FOOTING
3"Ø FENCE POST AT TYP, 6"Ø FENCE
POST AT CORNER, INTERSECTIONS,
& GATE LOCATIONS
ROUND CONCRETE
FOOTING, *D = 12" FOR 3"Ø
POST & 16" FOR 6"Ø POST
*D
ROUND AND SLOPE TOP OF
CONCRETE AWAY FROM POST
P O
S T
E M
B E
D
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:1
P
M
S101
TYPICAL STRUCTURAL DETAILS
08222.006
KMW
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 3- S101 TYPICAL STRUCTURAL DETAILS
SCALE: 3/4" = 1'-0"
TYPICAL REINFORCING DETAILS
SCALE: 3/4" = 1'-0"
TYPICAL CONCRETE FOOTING AT ADJACENT UTILITIES
SCALE: 3/4" = 1'-0"
TYPICAL ANCHOR ROD DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL FENCE POST FOOTING
EL. = MATCH EXISTING
FIN. GRADE
EL. = 42" BELOW
B.O.F.
EL. = 4' MIN ABOVE FIN GRADE
T.O. PIER
X
EL. = MATCH EXISTING
FIN. GRADE
EL. = 4' MIN ABOVE FIN GRADE
T.O. PIER
EL. = 42" BELOW
B.O.F.
X
EL. = MATCH EXISTING
FIN. GRADE
EL. = MATCH EXISTING
FIN. GRADE
EL. = MATCH EXISTING
FIN. GRADE
EL. = MATCH EXISTING
FIN. GRADE
EL. = 4' MIN ABOVE FIN GRADE
T.O. PIER
EL. = 12" BELOW FIN
T.O.F.
X
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
1" STEEL EMBED PLATE W/
(8) #6 BENT BARS
STEEL COLUMN - BY
SHADE MANUF.
3/4" CHAMFER AT ALL
EXPOSED CORNERS, TYP
24"x24" CONC PIER W/ (12) #7 VERT
BARS W/ #4 TIES @ 12" O.C., (2) @
TOP @ 2" O.C., TYP.
FINISHED GRADE
FIN GRADE, MIN
20"
E M
B E
D
6"
6'-6"x6'-6"x2'-0" CONCRETE
FOOTING W/ #6 BARS @ 12"
O.C. EA. WAY TOP & BOT
2" 8" 8" 2"
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
METAL COLUMN - BY
HOOP BLDG MANUF
STEEL BASE PLATE AND
ANCHORS - BY OTHERS
3/4" CHAMFER ALL SIDES, TYP
18"x18" CONCRETE PIER W/ (8) #
6 VERT BARS W/ #3 TIES @ 12"
O.C., (3) @ TOP @ 2" O.C., TYP.
T Y
P D
E T
A
IL
E M
B E
D P
E R
PROVIDE STEEL BOLT
CAPS FOR ALL
EXPOSED BOLTS, TYP.
6'-0"x6'-0"x2'-0" CONCRETE
FOOTING W/ #6 BARS @ 12"
O.C. EA. WAY TOP & BOT
FIN GRADE, MIN.
FINISHED GRADE
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
STEEL PIPE COLUMN BY
CABLE SYSTEM MANUF.
3/4" CHAMFER ALL SIDES, TYP
3'-0"x3'-0"x3'-6" CONC PAD
FOOTING W/ (4) #5 BARS
EA. WAY, TOP & BOT.
3'-0"
ROUND AND SLOPE TOP OF
CONCRETE AWAY FROM COLUMN
COLUMN
EMBEDMENT/ANCHORAGE
BY CABLE SYSTEM MANUF.
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
STEEL PIPE COLUMN BY
CABLE SYSTEM MANUF.
3/4" CHAMFER ALL SIDES, TYP
24"Ø SONOTUBE W/ (6) #6 VERT
BARS W/ #3 TIES @ 12" O.C., (3)
@ TOP @ 2" O.C., TYP.
ROUND AND SLOPE TOP OF
CONCRETE AWAY FROM COLUMN
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
WF STEEL COLUMN BY
CABLE SYSTEM MANUF.
3/4" CHAMFER ALL SIDES, TYP
36"Ø SONOTUBE W/ (10) #8 VERT
BARS W/ #5 TIES @ 12" O.C., (2)
@ TOP @ 2" O.C., TYP.
EMBEDMENT/ANCHORAGE
BY CABLE SYSTEM MANUF.
CENTERLINE OF COLUMN =
CENTERLINE OF FOOTING
METAL COLUMN - BY
HOOP BLDG MANUF
STEEL BASE PLATE AND
ANCHORS - BY OTHERS
3/4" CHAMFER ALL SIDES, TYP
18"x18" CONCRETE PIER W/ (8) #
6 VERT BARS W/ #3 TIES @ 12"
O.C., (3) @ TOP @ 2" O.C., TYP.
T Y
P D
E T
A
IL
E M
B E
D P
E R
PROVIDE STEEL BOLT
CAPS FOR ALL
EXPOSED BOLTS, TYP.
CONCRETE FOOTING -
SEE PLAN & SCHED
FOR SIZE AND REINF.
GRADE, MIN.
FINISHED GRADE
PROJECT NO.:
NO. DATE BY DESCRIPTION
REVISIONS
L BAETE
S Henk
USDAA-E FIRM
TJS
B DEAN
B DEAN
USDA
REAL PROPERTY
SAFETY & HEALTH
AREA ENGINEER
DRAWN BY
CHECKED BY
DESIGNER
PROJECT MANAGER
EPM
PROJECT NO.
DATE
SHEET
Service Research Agricultural
FACILITIES ENGINEERING SECTION
PLAINS AREA
2150 CENTRE AVE., BLDG D, SUITE 330
FT. COLLINS, CO 89526-8119
U S D A
CA
D
DH
DS
G
PM
C
U s e r s
\s o g le s b y \D o c u m e n ts \R e v it te m p
\0 -A
R C
H R s o g le s b y S
B E
J .r v t
/1
/2
:3
:1
P
M
S102
STRUCTURAL DETAILS
08222.006
KMW
MJN
MJN
3/17/2022
SHADE STRUCTURES
US MEAT ANIMAL RESEARCH CENTER
CLAY CENTER, NEBRASKA
ISSUED FOR
CONSTRUCTION
08222006- 3- S102 STRUCTURAL DETAILS
SCALE: 3/4" = 1'-0"
TYPICAL CANTILEVERED SHADE STRUCTURE FOOTING DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL HOOP BARN FOOTING DETAIL
SCALE: 3/4" = 1'-0"
TYPICAL END CABLE COLUMN FOOTING
SCALE: 3/4" = 1'-0"
TYPICAL INTERIOR CABLE COLUMN FOOTING
SCALE: 3/4" = 1'-0"
TYPICAL WIDE FLANGE CABLE COLUMN FOOTING
PAD FOOTING SCHEDULE
MARK PLAN SIZE DEPTH REINFORCING
F4.0 4'-0" X 4'-0" 3' - 0" (5) #6 BARS EA. WAY, TOP & BOT.
F4.5 4'-6" X 4'-6" 3' - 0" (5) #6 BARS EA. WAY, TOP & BOT.
F5.0 5'-0" X 5'-0" 3' - 0" (6) #6 BARS EA. WAY, TOP & BOT.
F5.5 5'-6" X 5'-6" 3' - 0" (6) #6 BARS EA. WAY, TOP & BOT.
NOTE:
ALL STEEL SHALL BE GALVANIZED AND
ALL WELDING BURRS AND SPATTER
SHALL BE GROUND SMOOTH
SCALE: 3/4" = 1'-0"
TYPICAL METAL BUILDING FOOTING DETAIL
USDA
ISSUED FOR
CONSTRUCTION
U
S
D
A
A-E FIRM
LEGEND
- WOVEN-WIRE FENCE
- FENCE GATE
- IRON PIPE FENCE
- UNDERGROUND TELEPHONE LINE
- WATER LINE
PROJECT NO.:
- POWER POLE
08222.006
| 08222006-0-COVER SHEET |
| 08222006-1-C000 |
| C000 |
| 08222006-2-A101-LOCATION 42 EAST |
| 08222006-2-A102-LOCATION 42 WEST |
| 08222006-2-A103-LOCATION 25 |
| 08222006-2-A104-LOCATION 46 |
| 08222006-2-A105-LOCATION 29 |
| 08222006-2-A106-LOCATION 14 |
| 08222006-2-A107-LOCATION 18 |
| 08222006-2-A108-LOCATION 12 |
| 08222006-2-A109-SHADE STRUCTURES & FENCING |
| 08222006-3-S 01 |
| 08222006-3-S101 |
| 08222006-3-S102 |
| 08222006-7-E101 |
| E101 |