This is a unit price form for tank and soil removal services across eleven Michigan districts: Detroit, Warren, Jackson, Kalamazoo, Lansing, Grand Rapids, Bay City, Cadillac, Gaylord, Western UP, and Eastern UP for 2025. The scope includes professional services such as site visits, excavation planning, UST removal oversight, construction reporting, monitoring well installation and abandonment, soil vapor monitoring, and various tank-related services. The work encompasses UST system closure and removal for tanks ranging from 0-1,000 gallons up to 15,001-20,000 gallons, along with associated excavation, transportation, and disposal of hazardous and non-hazardous materials.
The pricing structure is organized into nine major categories: Project Administration, Professional Services, UST System Close in Place, UST System Removal and Disposal, Excavation/Transportation/Disposal, Waste Characterization and Disposal, Miscellaneous Services, Site Restoration, and Mobilization/Demobilization. Each district has identical line items but allows for different unit pricing based on location. A standard provisionary allowance of $10,000 is included for each district. Pricing is requested in various units including percentage of design and construction, lump sum, per day, linear foot, ton, gallon, drum, square foot, and cubic yard measurements.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Detroit District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: DETROIT DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Warren District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: WARREN DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Jackson District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: JACKSON DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Kalamazoo District Unit Prices
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: KALAMAZOO DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Lansing District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: LANSING DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Grd Rpds District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: GRAND RAPIDS DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Bay City District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: BAY CITY DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Cadillac District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: CADILLAC DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Gaylord District Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: GAYLORD DISTRICT - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Western UP Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: WESTERN UP - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |
Eastern UP Unit Pricing
| 2025 Tank & Soil Removal ISID Unit Pricing | |||
| BIDDER NAME: | |||
| DISTRICT: EASTERN U.P. - UNIT PRICING | |||
| Line Item | Description | Units | Unit Price |
| 1a | Project Administration | % of D&C | |
| 2 | Professional Services | ||
| 2a | Site Visit (Maximum of 3) | Each | |
| 2b | Excavation Plans/Drawings | Lump Sum | |
| 2c | UST Removal/Excavation Oversight | Day | |
| 2d | Construction/Removal Report | Lump Sum | |
| 2d1 | Test Pitting Tech Memo | Lump Sum | |
| 2e | Notification to Remove and UST registration | Lump Sum | |
| 2f | UST Removal (Part 211) Site Assessment and Reporting | Lump Sum | |
| 2g | Monitoring Well Abandonment | Lineal Foot | |
| 2h | Monitor Well Installation - Hollow Stem Auger | Lineal Foot | |
| 2i | Mobilization and Demobilization - Hollow Stem Auger Drilling Equipment | Lump Sum | |
| 2j | Monitor Well Installation – Geoprobe | Lineal Foot | |
| 2k | Mobilization and Demobilization - Geoprobe Equipment for Monitoring Well and Soil Vapor Monitoring Point Installation | Lump Sum | |
| 2l | Groundwater Monitoring and Reporting | Event | |
| 2m | Soil Vapor Monitoring Points Installation- Geoprobe | Lineal Foot | |
| 2n | Sub Slab Soil Gas Vapor Pin Installation | Each | |
| 2o | Soil Vapor Monitoring and Reporting | Event | |
| 3 | UST System Close in Place (includes removing liquids and sludges, cleaning and filling with an inert solid material) | ||
| 3a | 0 - 1000 gallon | Tank | |
| 3b | 1001 - 4000 gallon | Tank | |
| 3c | 4001 - 6000 gallon | Tank | |
| 3d | 6001 - 8000 gallon | Tank | |
| 3e | 8001 - 10,000 gallon | Tank | |
| 3f | 10,001 - 12,000 gallon | Tank | |
| 3g | 12, 001 - 15,000 gallon | Tank | |
| 3h | 15,001 - 20,000 gallon | Tank | |
| 4 | UST System Removal and Disposal (includes purging, cleaning and all associated piping) | ||
| 4a | 0 - 1000 gallon | Tank | |
| 4b | 1001 - 4000 gallon | Tank | |
| 4c | 4001 - 6000 gallon | Tank | |
| 4d | 6001 - 8000 gallon | Tank | |
| 4e | 8001 - 10,000 gallon | Tank | |
| 4f | 10,001 - 12,000 gallon | Tank | |
| 4g | 12, 001 - 15,000 gallon | Tank | |
| 4h | 15,001 - 20,000 gallon | Tank | |
| 5 | Excavation, Transportation, and Disposal of Non-Hazardous Soil and Excavation Backfill | ||
| 5a | 0- 250 tons | Ton | |
| 5b | 251 - 500 tons | Ton | |
| 5c | 501 - 1000 tons | Ton | |
| 5d | 1001 - 2000 tons | Ton | |
| 5e | > 2000 tons | Ton | |
| 6 | Waste Characterization and Disposal | Units | |
| 6a | Non- Hazardous Liquid | Gallon | |
| 6b | Hazardous Liquid | Gallon | |
| 6c | Hazardous Solid / Sludge | Gallon | |
| 6d | 55-gallon drum removal - Non-Hazardous Solid/Sludge | Drum | |
| 6e | 55-gallon drum removal - Hazardous Solid/Sludge | Drum | |
| 7 | Miscellaneous | ||
| 7a | Vac Truck and Operator | Day | |
| 7b | Site Preparation Including Excavation Sloping and Overburden Stockpiling | Cubic yard | |
| 7c | Clearing and Chipping Dense & Woody Vegetation | Day | |
| 7d | Provisionary Allowance | Allowance | $10,000.00 |
| 7e | Concrete Disposal/Recycling | Sq. Foot | |
| 7f | Asphalt Disposal/Recycling | Sq. Foot | |
| 7g | 5,000-gallon Frac Tank | Day | |
| 7h | Air Monitoring | Day | |
| 7i | Test Pitting Services | Day | |
| 7i1 | Mobilization Fee for Test Pitting Services ONLY | Lump Sum | |
| 7i2 | Saw Cut Concrete (<6 inches) | Lump Sum | |
| 7i3 | Saw Cut Concrete (>6 inches) | Lump Sum | |
| 7i4 | Saw Cut Asphalt | Lump Sum | |
| 8 | Site Restoration | ||
| 8a | 22a Gravel | Ton | |
| 8b | Crushed Limestone | Ton | |
| 8c | Asphalt Paving (4" Thick) | Sq. Foot | |
| 8d | Concrete | cubic yard | |
| 8e | 2" Topsoil and Seeding | Sq. Foot | |
| Subtotal Construction | |||
| 9 | Mobilization, Demobilization and General Conditions | % of construction | |
| Subtotal Design & Construction (D&C) |