Trail_Edge_Detail.pdf

PDF 192 KB Posted

Attached to
Master Services Agreement for Trail Edge Restoration and Repairs
Solicitation number
CC-5888-24/HSM
Issued by
Seminole County, Florida

About this file

The document is a detailed Trail Edge Detail engineering drawing prepared for Seminole County, Florida's Leisure Services Greenways & Natural Lands Department, located at 100 E 1st Street in Sanford. The drawing provides a comprehensive technical specification for constructing a concrete trail edge, including precise layering requirements such as 12" minimum subbase compacted to 98% maximum density, 6" thick limerock base compacted to 98%, and 2" asphalt surface. The drawing specifies using 3,000 PSI concrete with control joints and a tooled edge, and includes structural design criteria referencing multiple building and engineering codes including the Florida Building Code 2020 Edition.

The drawing includes structural design parameters such as a design wind speed of 140 MPH, an assumed safe bearing pressure of 2,000 PSF, and guidelines for soil preparation, including removing unsuitable soil and replacing it with clean structural fill compacted in 8-inch layers to 95% density. The document is stamped with a registration number (0001764) and prepared by landscape architect Carl J. Kelly Jr., RLA, and represents technical specifications that would likely be used in the context of the related Seminole County Master Services Agreement for Trail Edge Restoration and Repairs project, which has an engineer's estimated project cost of $328,750.00.

View the file

Other files

Show all 13

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

12" MIN. SUBBASE COM-

PACTED TO 98% MAX.

6" THICK LIMEROCK BASE

COMPACTED TO 98%

2" ASPHALT

DENSITY (AASHTO-T180)

DENSITY AASHTO T-180

@ 10' O.C.

- PROVIDE 3,000 PSI CONCRETE

- PROVIDE CONTROL JOINTS

NOTE:

TOOLED EDGE

Concrete Trail Edge Detail

SCALE: 1/2" = 1'-0" HS-01

VERIFIED BY OWNER PRIOR TO INSTALLATION.

ALL DIMENSIONS AND PLACEMENTS SPECIFIED WITHIN THIS DRAWING ARE TO BE

THE GENERAL CONTRACTOR SHALL FIELD MEASURE ALL DIMENSIONS PRIOR

TO FABRICATION OR START OF CONSTRUCTION.

AWS D1.2 STRUCTURAL WELDING CODE - ALUMINUM

SPECIFICATIONS FOR ALUMINUM STRUCTURES, FOURTH EDITION.

AWS D1.1 STRUCTURAL WELDING CODE - STEEL.

AISC SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS, A.S.D., NINTH EDITION.

REQUIREMENTS STIPULATED IN GEOTECHNICAL REPORT.

CONTRACTOR SHALL PREPARE THE SUBSURFACE SOILS PER THE GEOTECHNICAL

22 PSF

ASSUMED SAFE BEARING PRESSURE = 2,000 PSF.

FLORIDA BUILDING CODE - 2020 EDITION

CODES, STANDARDS AND SPECIFICATIONS.

STRUCTURAL DESIGN CRITERIA:

INSURE POSITIVE DRAINAGE IN ALL AREAS.

CONTRACTOR TO VERIFY ALL UTILITIES PRIOR TO CONSTRUCTION.

ACI 530-99, BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES

ACI 318-02, BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE.

ASCE 7-02 MIN. DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES.

STRUCTURAL DESIGN IS IN ACCORDANCE WITH THE GOVERNING PROVISIONS OF THE FOLLOWING

AND COMPACTED TO 95% (ASTM D698 - STANDARD PROCTOR) OF MAX. DRY

STRUCTURAL FILL PLACED IN LOOSE LAYERS NOT EXCEEDING EIGHT (8") INCHES

ALL UNSUITABLE SOIL SHALL BE REMOVED AND REPLACED WITH CLEAN

A.

D.

C.

B.

1.

GENERAL:

3.

2.

DENSITY.

DESIGN WIND PRESSURE:

WIND LOADS:

SUPERIMPOSED DESIGN LOADS:

LIVE LOADS (MIN):

FOUNDATIONS:C.

B.

GENERAL: 20 PSF

8.

7.

6.

5.

4.

A.

3.

2.

1.

DEAD WEIGHT

DEAD LOADS:

DESIGN WIND SPEED: 140 MPH

MEAN ROOF HEIGHT: =15 FEET

STRUCTURE: SIGN, CF=1.2, G=.85

EXPOSURE = B

TRAIL EDGE DETAIL

Seminole County, Florida

Leisure Services Greenways & Natural Lands 100 E 1st Street Sanford, FL 32771

PH: (407) 665-2001

AutoCAD SHX Text

LANDSCAPE ARCHITECT

AutoCAD SHX Text

CARL J. KELLY JR., RLA

AutoCAD SHX Text

REG.#: 0001764

Sheets and Views
HS-01

File details come from the government source that posted it. Updated .