This is a technical manual for the Grease Interceptor Gaylord Hood, a naval shipboard ventilation and grease extraction system manufactured by Gaylord Industries, Inc. and distributed by Halter Marine Inc. The document, classified as T6161-DX-FSE-010 and dated 15 July 1990, serves as the official equipment manual for installation, operation, maintenance, and repair of the system.

The Gaylord Grease Interceptor Hood is designed to extract 95% of grease, dust, and lint particles from air streams without filters or moving parts, eliminating fire hazards and maintenance problems associated with duct accumulation. The system operates at 250 CFM per linear foot of ventilator (or 150 CFM for Custom Air Series) and requires 115 Volt, 60 Hertz, single-phase electrical service. Hot water requirements are 140°F to 180°F at 40-80 PSI, with consumption of 0.80 GPM per foot at 40 PSI. The hood measures 7'6" long by 36" deep by 47" high, weighs 375 lbs, and includes a Model CG-NAB-24 hood, Model N66/115 Damper Control Switch, Model NGPC-200/115/75 Ventilation Control Cabinet, and Model 222-2062-NHZ Fail-Safe Thermostat set to open at 250°F ±5°F. The manual contains detailed chapters on operation, functional description, scheduled maintenance, troubleshooting, corrective maintenance procedures (including solenoid replacement), illustrated parts breakdowns, and installation engineering data. The system includes automatic cleaning via detergent pump cycle (3-10 minutes adjustable) and automatic fire protection through fail-safe thermostat activation that closes the fire damper and shuts off the exhaust fan at 250°F.

View the file

Other files for this federal contract opportunity

Other files attached to MO FY27 Thomas Jefferson Drydock REFERENCES and ATTACHMENTS, newest first.
File Type Posted
NOAA Standard Specification 000-1H General Requirements for Ship Repair Contract Work.pdf PDF
NOAA Standard Specification 630-1 Preservation of Ship Structures.pdf PDF
NOAA Standard Specification AMC-533-1 Potable Water Tank System Disinfection.pdf PDF
NOAA Standard Specification MOC-510-1B HVAC Cleaning.pdf PDF
NOAA Standard Specification MOC-631-2D Coatings for Steel Surfaces.pdf PDF
NOAA Standard Specification MOC-635-1 Thermal Insulation for Piping.pdf PDF
NOAA Standard Specification AMC-573-1C Testing of Davits and Weight Handling Gear.pdf PDF
NOAA Standard Specification AMC-581-A Inspection and Preservation of Ground Tackle.pdf PDF
631-6634619 Paint Schedule.pdf PDF
ABS Steel Vessel Rules.pdf PDF
1102-13 - Gangway Handling (public).docx DOCX document
NOAA Form 57-17-09 - Hot Work Permit.pdf PDF
TJ-311-01 EDG Engine.pdf PDF
TJ-583-02A_Davit Rescue Boat.pdf PDF
TJ-436-01A - Consilium Salwico CS4000 Operations Manual.pdf PDF
ClearFlo Manual v1103.pdf PDF
TJ-436-02 FireBoy - Owners Manual and Install Instructions.pdf PDF
Electro-Motive MI 1722_Maintenance Instruction.pdf PDF
TJ-233-03 EMD Engine_Maintenance Instruction_1722 Rev I.pdf PDF
514-3275003-12 Rev A AC PP INSTALL FCSLE DK and ABV.pdf PDF
633-67635_Installation Drawing ICCP Equipment.pdf PDF
601-6634924 Joiner Arrangement Bridge Deck.pdf PDF
601-6634922 Joiner Arrangement Forecastle Deck.pdf PDF
601-6634923 Joiner Arrangement Upper Deck.pdf PDF
528-6634786D Plumbing and Deck Drain Arrangement.pdf PDF
301-001B_Electrical One Line Dia.pdf PDF
556-6634805C Hydraulic Systems Info.pdf PDF
320-6634677 Cableway Routing and Penetrations - redline.pdf PDF
THOMAS JEFFERSON Diamond System Builder 1-30-1.pdf PDF
N61-T52-01064-1 Rev C - Sensor Alignment Survey.pdf PDF
436-6634706 Rev C_ACCU elementary wiring diagram - redline.pdf PDF
512-004_-_HVAC Makeup Air Modifications.pdf PDF
TJ_85_TJ-085-003_RevA_DOCKING PLANS.pdf PDF
437-6634704 Tank Level Indicating Sys EWD - redline.pdf PDF
101-6634870 Structural Module 11.pdf PDF
101-6634873 Structural Module 14.pdf PDF
320-6634691 Cable Wtrtight Penetrations.pdf PDF
TJ-437-003 TLI Installation Modifications.pdf PDF
514-3275003-11 REV A AC PIPING INSTL MN DK.pdf PDF
101-6634874_Structural Module Assembly No 15.pdf PDF
512-3275003-8 HVAC MODS MN DECK REV B.pdf PDF
581-6634884_Anchor Handling Details.pdf PDF
TJ-551-003C SSDG UPGRADES COMPRESSED AIR MODS.pdf PDF
243-6634745 Shaft Brake Arrngmnt.pdf PDF
512-6634841_ HVAC Diagram.pdf PDF
261-6634755D Fuel Oil Service Diagram.pdf PDF
601-6634920 Joiner Arrangement Lower Deck and Flat.pdf PDF
633-6634726A_Cathodic Protection Elementary Wiring Diagram.pdf PDF
TJ-635-6634624_Insulation Layout and Details.pdf PDF
801-6634640_Hull Lines.pdf PDF
Show all 50

MO FY27 Thomas Jefferson Drydock REFERENCES and ATTACHMENTS has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

COVER

TOC
LOT
TAB 1-1
TAB 2-1
TAB 5-1
TAB 8-1
TAB 8-2
TAB 8-3
LOI
FIG 1-1
FIG 1-2
FIG 1-3
FIG 1-4
FIG 1-5
FIG 2-1
FIG 2-2
FIG 2-3
FIG 3-1
FIG 3-2
FIG 3-3
FIG 3-4
FIG 3-5
FIG 3-6
FIG 5-1
FIG 5-2
FIG 6-1
FIG 7-1
FIG 7-2
FIG 7-3
FIG 7-4
FIG 7-5
FIG 8-1
FIG 8-2
SECTIONS
-CHAPTER 1
-PARA 1-1
-PARA 1-1.1
-PARA 1-1.2
-PARA 1-2
-PARA 1-3
-CHAPTER 2
-PARA 2-1
-PARA 2-2
-PARA 2-2.1
-PARA 2-2.2
-PARA 2-3
-PARA 2-3.1
-PARA 2-3.2
-PARA 2-3.3
-PARA 2-3.4
-PARA 2-3.5
-CHAPTER 3
-PARA 3-1
-PARA 3-2
-PARA 3-2.1
-PARA 3-2.2
-PARA 3-2.3
-PARA 3-2.4
-PARA 3-3
-CHAPTER 4
-PARA 4-1
-PARA 4-2
-PARA 4-2.1
-PARA 4-2.2
-PARA 4-2.3
-PARA 4-2.4
-PARA 4-2.5
-PARA 4-3
-CHAPTER 5
-PARA 5-1
-PARA 5-2
-PARA 5-2.1
-PARA 5-2.2
-PARA 5-2.4
-PARA 5-2.5
-PARA 5-2.6
-CHAPTER 6
-PARA 6-1
-PARA 6-2
-PARA 6-2.1
-PARA 6-2.2
-CHAPTER 7
-PARA 7-1
-PARA 7-2
-CHAPTER 8
-PARA 8-1
-PARA 8-2
-PARA 8-2.1
-PARA 8-2.2
-PARA 8-2.3
-PARA 8-2.4
-PARA 8-2.5
-PARA 8-2.6
-PARA 8-2.7
-PARA 8-3
-PARA 8-4
-PARA 8-5

File details come from the government source that posted it. Updated .