TGI_38HVC60001_A02_c0v0.pdf
PDF 296 KB Posted
- Solicitation number
- N6264926RA041
About this file
This is a Task Group Instruction (TGI) for naval ship alteration work on USS BARGE (YR-85), specifically for Ship Alteration (S/A) YR-1116D to accomplish conversion of a break room in compartment 02-88-0-L. The work is prepared by Code 231A personnel and approved by Code 231A management, with a preparation date of 10 April 2026.
The scope encompasses structural work, sheet metal work, and preservation work including installation of a metal joiner bulkhead, one metal joiner door (26 inches width x 76 inches height, Type E, non-tight, right hand), furnishings, HVAC modifications with recirculating system ducting and two acoustic vent hoods, power and lighting systems, interior communication systems, cold and hot potable water piping for a service sink (copper, MIL-T-24107 specification), plumbing drain and vent piping (Cu-Ni 90/10, MIL-T-16420 specification), and patch plates for deck and bulkhead penetrations. Critical requirements include fabrication and staging of a non-flammable closure due to work affecting a fire zone boundary, cleanliness standards for piping systems (Level II and III), and classification standards for piping (P-3b and P-2). The instruction references multiple engineering drawings, requires hydrostatic testing of potable water systems at 135 PSIG, flow checks of drain piping, air hose testing of patch plates, and compliance with preservation standards. Appendices include a material list identifying over 125 line items to be furnished by the contractor, a deficiency form template, and detailed engineering instruction enclosures addressing electrical systems, patch installation specifications, and shop test records for potable water system piping.
View the file
Other files
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOUO
FOUO: Public availability to be determined under 5 USC 552
TASK GROUP INSTRUCTION
AIM REV 20.11.4.0 (OCTOBER 2020)
TGI COMPONENT NAME: TYPE: PHASE: REPEAT: CHANGE:
NO.: S/A YR-1116D AY A 1 0
SHIP/HULL NO.: SHIP/HULL NAME: SYSTEM: PROJ/WO NO: CASREP CAT:
YR-85 YR 85 HVC
CU PHASE TITLE:
F/O – SA YR-1116D, ACCOMPLISH CONVERSION OF BREAK ROOM IN 02-88-0-L
PREPARING ACTIVITY:
PREPARED BY: CODE PHONE DATE
YOSHINORI AOKI 231A 315-243-4503 10-APR-2026
APPROVED BY: CODE PHONE DATE
YUUJI NAKAMURA 231A 315-243-6041 10-APR-2026
CONCURRED BY: CODE PHONE DATE
CONCURRED BY: CODE PHONE DATE
CONCURRED BY: CODE PHONE DATE
CONCURRED BY: CODE PHONE DATE
REASON FOR WORK/NEED FOR CHANGE:
CHANGE INSTRUCTIONS:
SPECIAL REQUIREMENTS:
This work affects a fire zone boundary. Fabrication and/or staging of a non-flammable closure is required, CLEANLINESS FOR PIPING SYSTEM/EQUIPMENT LEVEL II and III, CLASS P-3b PIPING, CLASS P-2 PIPING.
WORK CERTIFICATION SIGNATURES
COMPLETION OF WORK REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:
ACCEPTANCE OF COMPLETED WORK
PHYSICAL INSPECTION PHYSICAL INSPECTION COMPLETED: BADGE NO.: SHOP/CODE: PHONE: DATE:
REQUIRED:☐YES ☒NO
RECORDS REVIEW: BADGE NO.: SHOP/CODE: PHONE: DATE:
TGI NO.: S/A YR-1116D AY A 1
FOUO
SHIP: YR-85 CHG/VER: 0/0
LIST OF EFFECTIVE PAGES
SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO. SHT NO. CHG NO.
1-7 Engrg Inst (1-2)
J1-2 QA28
(1)
M1-12 Engrg Inst (1)
1. SCOPE/PURPOSE
1.1 Title: SA YR-1116D, Conversion of Break Room in 2-88-0-L; accomplish
1.2 Location of Work:
1.2.1 03 Level Weather, Frames between 88 and 100, Port, Starboard (Stbd), and Ship’s Center Line
1.2.2 Break Room (02-88-0-L)
1.2.3 02 Level Weather, Frames between 88 and 101, Port, Stbd, and Ship’s Center Line
1.2.4 Womens Wr and Wc (02-83-1-L)
1.2.5 Mens Wr and Wc (02-83-2-L)
1.2.6 Womens Wr, Wc, and Sh (01-83-0-L)
1.2.7 Wones Locker room (Dirty Side) (01-88-0-L)
1.2.8 Mens Locker Room (Dirty Side) (01-94-0-L)
1.2.9 Mens Shower Room (01-88-1-L)
1.2.10 Passage (1-90-0-L)
1.2.11 Supervisor Office (1-92-1-Q)
1.2.12 Womens Wr and Wc (1-92-2-L)
1.2.13 Shop 86 Muster/Office (02-90-0-Q)
1.3 Identification:
1.3.1 Quantity (One Lot), Structural Work, Sheet Metal Work, and Preservation Work for S/A YR-1116D for Convert Break Room
Remarks: See 2.3 through 2.8 and Engrg Inst Enclosure-01 for material and details.
1.3.1.1 Quantity (One Lot), Metal Joiner Bulkhead
Remarks: See 2.3, 2.9, and 2.10 for material and details.
FOUO
SHIP: YR-85 CHG/VER: 0/0
1.3.1.2 Quantity (One EA), Metal Joiner Door
Door No.: 02-90-1 Size: 26 Inches Width x 76 Inches Height, Clear Opening Type: E, Non-tight, Right Hand Remarks: See 2.3 for details.
1.3.1.3 Quantity (One Lot), Furnishing in 02-90-0-Q
Remarks: See 2.4 and 2.8 for details.
1.3.1.4 Quantity (One Lot), HVAC Member including Vent Duct Assembly and Duct Hanger
System No.: Recirculating System (RS) 02-81-1 Type: Non-Watertight Remarks: See 2.5 for details.
1.3.1.5 Quantity (2 EA), Vent Hood
System No.: Natural System Size: 14 Inches Width x 6 Inches Depth x 18 Inches Height Type: Acoustic Remarks: See 2.5 for details.
1.3.1.6 Quantity (12 SF), Duct Insulation, Frames between 88 and 90, Starboard
Material: Thermal, Fiber Grass, One Inch Thickness, MIL-DTL-32585, Type I, Form 1, Facing B Remarks: See 2.5 for details.
1.3.2 Quantity (One EA), Power System
Remarks: See 2.11 for details
1.3.3 Quantity (One EA), Lighting System
Remarks: See 2.7, 2.8, 2.12, 2.13 and Engrg Inst Enclosure-01 for details
1.3.4 Quantity (One EA), Interior Communication System
Remarks: See 2.7, 2.14 and 2.15 for details
1.3.5 Quantity (One Lot), Cold Potable Water Piping for Service Sink
Size: 1-1/2 Inch IPS (1.900 Inch OD X 0.065 Inch WT) 1/2 Inch IPS (0.840 Inch OD X 0.065 Inch WT) Material: Copper Specification: MIL-T-24107 Remarks: See Sheet 2 of 2.17 and Sheet 7 (Zone 51-C and 52-C) of 2.18 for details.
1.3.6 Quantity (One Lot), Hot Potable Water Piping for Service Sink
Size: 1-1/2 Inch IPS (1.900 Inch OD X 0.065 Inch WT) 1/2 Inch IPS (0.840 Inch OD X 0.065 Inch WT) Material: Copper Specification: MIL-T-24107 Remarks: See Sheet 2 of 2.17 and Sheet 7 (Zone 51-C and 52-C) of 2.18 for details.
FOUO
SHIP: YR-85 CHG/VER: 0/0
1.3.7 Quantity (One Lot), Plumbing Drain and Vent Piping for Service Sink
Size: 1-1/2 Inch IPS (1.900 Inch OD X 0.065 Inch WT) One Inch IPS (1.315 Inch OD X 0.065 Inch WT) Material: Cu-Ni 90/10 Specification: MIL-T-16420 Remarks: See Sheet 2 of 2.19 and Sheet 8 (Zone 60-D) and Sheet 9 (Zone 67-D) of 2.20 for details.
1.3.7.1 Quantity (2 EA), Cap
Size: 1-1/2 Inch IPS and One Inch IPS Material: Bronze Specification: MIL-DTL-1183 Remarks: See Sheet 2 of 2.19 for detail.
1.3.8 Quantity (One Lot), Patch Plate for Deck and Bulkhead
Item No.: F1 of 2.17 and 2.19 Material: Steel Specification: MIL-S-22698, GR-A Remarks: See 2.17 and 2.19 and Engrg Inst Enclosure-02 for material and details.
1.4 Security Classification: None.
1.5 Initial Condition:
1.5.1 Potential Asbestos Hazard
1.6 Contractor work start date:
1.7 Contractor work completion date:
2. REFERENCES:
REF.
NO.
DOCUMENT
/DRAWING
NUMBER
DOCUMENT/DRAWING TITLE REV CHG
NO.
COPY
REQ’D
(Y/N)
SOURCE
DOC
(Y/N)
PARA SEC PG CHP
1 NSI FY26 Standard Item - 1 N 2 LI FY26 Local Standard Items - ORG N
3 DWG 604-
8894011
SHIPALT YR-1116D BREAK
ROOM TO MUSTER
CONVERSION METAL JOINER
BULKHEAD & DOOR MO
- Y AL
L
4 DWG 613-
8894013
SHIPALT YR-1116D BREAK
ROOM TO MUSTER
CONVERSION SHOP 86
MUSTER/OFFICE ARRANGEME
5 DWG 501-
8975491
SHIPALT YR-1116D HVAC
MODIFICATION (02-90-0-Q)
6 DWG 145-
8894014
SHIPALT YR-1116D BREAK
ROOM TO MUSTER AREA
COMPARTMENT & ACCESS
MODIFICATION
7 LAR
YR1116D/Y
R85/0067A
BREAKROOM TO MUSTER
DRAWING COMMENTS
8 LAR
YR1116D/Y
R85/0107A
02 Level Office/Muster Emergency Egress
FOUO
SHIP: YR-85 CHG/VER: 0/0
REF.
NO.
DOCUMENT
/DRAWING
NUMBER
DOCUMENT/DRAWING TITLE REV CHG
NO.
COPY
REQ’D
(Y/N)
SOURCE
DOC
(Y/N)
PARA SEC PG CHP
9 DWG 604-
7579459
SHIPALT (TBD) YR85 METAL
JOINER BULKHEADS
B Y AL
L
10 DWG 804-
1426382
Bulkhead, Joiner, Metal, Details N N
11 DWG 302-
8974899
SHIPALT YR-1116D Power System Modifications Breakroom to Muster
- Y AL
L
12 DWG 303-
8974900
SHIPALT YR-1116D Receptacle System Modifications Breakroom to Muster
- Y AL
L
13 DWG 303-
8974901
SHIPALT YR-1116D Lighting System Modifications Breakroom to Muster
- Y AL
L
14 DWG 401-
8893282
SHIPALT YR-1116D IC Modification Incidental Breakroom (02-88-0-L)
- Y AL
L
15 LAR
YR1116D/Y
R85/0073A
BREAKROOM TO MUSTER
DRAWING COMMENTS
A Y AL
L
16 MIL MIL-
STD-2003
Electric Plant Installation Standard Methods for Surface Ships and Submarines
B N
17 DWG 509-
8895112
SHIPALT YR-1116D POTW PIPING
REMOVAL BREAK ROOM
MUSTER 02 LEVEL, FR 86-94 (P)
- Y AL
L
18 DWG 509-
8354582
FRESH WATER PIPING SYSTEM
DIAGRAM
A Y 7
19 DWG 505-
8895113
SHIPALT YR-1116D DRAIN &
PLUMBING VENT REMOVAL
BREAK ROOM MUSTER 02 LEVEL
- 01 L
- Y AL
L
20 DWG 505-
8354581
PLMB DRAINS & CHT PIPING
SYSTEM DIAGRAM
A Y 8,9
3. APPENDICES:
3.1. Appendix “J” TGI Job Summary Information Sheet
3.2. Appendix "M" TGI Material List
3.3. Appendix “D” Deficiency Form
4. GENERAL REQUIREMENTS:
4.1 Not Applicable.
5. PROCEDURE:
5.1 Accomplish the structural, sheet metal, and preservation work for S/A YR-1116D listed in 1.3.1 in accordance with 2.3 through 2.8, using 2.9 and 2.10 for guidance.
5.1.1 Remove each existing duct insulation listed in 1.3.1.6.
5.1.1.1 Accomplish the requirement of 009-011 of 2.1 to install each new thermal insulation listed in 1.3.1.6.
5.1.2 Accomplish the requirements of 009-012 of 2.1, including Table 4, Column(s) A and D, Lines One through 7.
5.2 Accomplish electrical removals, modifications and installations of the system listed in 1.3.2 through 1.3.4 in accordance with 2.7, 2.8, 2.11 through 2.15 and Enclosure-01.
5.2.1 Electrical installations must be in accordance with 2.16.
------------------------------------------------------------------------------ Rose, Aaron J. C1209.4
FOUO
SHIP: YR-85 CHG/VER: 0/0
5.2.2 Accomplish the requirements of 009-012 of 2.1, including Table 4, Column(s) A, Lines One through 7.
5.3 Accomplish the piping work for S/A YR-1116D listed in 1.3.5 through 1.3.8 in accordance with 2.17, 2.19, and Enclosure-02, using 2.18 and 2.20 for guidance.
5.3.1 Accomplish the requirements of 009-087 of 2.1.
5.3.1.1 Accomplish the requirements of 009-009 of 2.1 for chlorination and bacteriological tests. Analysis and testing conducted by a qualified Japanese laboratory (accredited by ISO 17025 or equal) are authorized by the
SUPERVISOR.
5.3.1.2 Record results of chlorination and bacteriological tests on a Laboratory Analysis Record(s) and DD Form 686, and submit one legible copy, in hard copy or electronic media, of completed record(s) and form(s) to the Project Team.
5.3.2 Accomplish the requirements of 009-012 of 2.1, including Table One, Column(s) A and B Lines One through 10.
5.3.3 Accomplish the requirements of 009-012 of 2.1, including Table 4, Column(s) A, Lines One through 7.
5.3.4 Accomplish the requirements of 009-071 of 2.1 for hydrostatic test, using clean, fresh water at 135 PSIG, for new and disturbed potable water piping systems listed in 1.3.5 and 1.3.6.
5.3.4.1 Document shop hydro test results on QA Form 28 Enclosure-03-1.
5.3.5 Accomplish flow check of plumbing drain piping listed in 1.3.7, using clean, fresh water. Allowable external leakage: None.
(V) (G) "FLOW CHECK"
5.3.6 Accomplish the requirements of 009-025 of 2.1 for a local air hose test of each patch plate listed in 1.3.8.
Allowable leakage: None.
5.4 Accomplish the requirements of 009-032 on 2.1 for each new and disturbed surface.
5.5 Notes:
5.5.1 Planner: Code 231A Y. Aoki, 243-4503
Planner: Code 231A K. Yasuo, 243-1108 Planner: Code 233 K. Ono, 080-9350-1438 Planner: Code 234 S. Yamashita, 070-7787-2035 Engineer: Code 250 K. Nogi, 243-5294 Engineer: Code 270 S. Takahashi, 243-0986
5.5.2 Work Integration Manager (WIM): Code 312 Dean Vanderwage, 243-3199
5.5.3 Work per this instruction involves cutting an access (or removal of a door) through a fire zone bulkhead, through the hull of the ship above the turn of the bilge, through ventilation components (ducting, plenums, etc.), or through any air-tight, fume-tight or watertight bulkhead normally used to control air flow in the event of a shipboard fire. A non- flammable closure is required in accordance with COMNAVDEASYSCOM MSG R 261400Z JUL 12. The closure, if not continuously in use, shall be staged near the access, readily visible and accessible, so that any emergency responder can install the closure to affect proper air flow onboard the ship.
5.5.4 JCN Y852-4027 is related to this TGI.
FOUO
SHIP: YR-85 CHG/VER: 0/0
5.6 Government Furnished Material (GFM)
5.6.1 SRF-JRMC will provide GFM listed in Appendix ”M”.
5.7 SRF-JRMC will provide the following service work: (TGI No. 38HVC60001S01)
5.7.1 [C740] Crane and crane rigging service.
5.7.2 [X99E] Utility service, electrical.
5.7.3 [X99M] Utility service, including water supply, steam supply, and low pressure air supply.
5.7.4 [C106.1] Safety inspection for SRF-JRMC employees.
5.7.5 [C106.2] Gas free inspection for SRF-JRMC employees.
5.7.6 [C133] QA inspection for (G) symbol(s).
FOUO
M-1
SHIP: YR-85 CHG/VER: 0/0
APPENDIX “M”
TGI MATERIAL LIST
SYSTEM: PLANT NO.: COMPONENT NAME: TYPE: PHASE: REPEAT: CU PH
VERSION:
CASREP
CAT:
S/A YR-1116D AY A 1 0
CU PHASE TITLE:
F/O – SA YR-1116D, ACCOMPLISH CONVERSION OF BREAK ROOM IN 02-88-0-L
MATERIAL REFERENCES
REF
NO.
DOCUMENT/DRAWING
NUMBER
DOCUMENT/DRAWING TITLE REV
1 401-8893282 - 2 303-8974901 - 3 123-8894012 - 4 509-8895112 - 5 145-8894014 - 6 501-8975491 - 7 613-8894013 - 8 604-8894011 - 9 505-8895113 - 10 303-8974900 -
11 LAR YR1116D/YR85/0073
12 145-8894014-PC3
JOB ORDER: KEY OP:
38HVC60001 A02
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
500 18 1 M NUT,SELF, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 002416604 NA 4 N 50105288 5/EA
501 11 2 M CIRCUIT BREAKER, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5925 002047488 NA 4 N 50935541 2/EA
NOTES:
FOUO
M-2
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
502 12 2 M YOKE,CIR, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5925 002020938 NA 4 N 50105216 1/EA
503 1 3 M SCUTTLE,MARINE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
3B 2040 007254519 NA 4 N 50105620 1/EA
504 3 3 M PIPE,METAL, PIPE, METAL,
SEAMLESS, SPEC: MIL-P-
24691/1, GRADE A, SIZE: 2" IPS
SCHEDULE 40, MATL: CARBON
STEEL,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4710 LL4599429 NA 4 N 50167543 2/FT
505 F4 4 M INSULATI, INSULATION, PIPE,
BRAND: K-FLEX ECO,
SPECIFICATION COMPLIANCE:
EB 4013,
FOR SIZE: 2-1/8" OD TUBE,
SIZE: 2-1/8" ID X 3/4" THK X 6
FT LG,
UI: EA/6 FT(ONE CONTINUOUS
LENGTH REQUIRED),
MATL: NON-HALOGEN,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5640 LL9607843 NA 4 N 50137466 2/EA
506 14 2 M CABLE,POWER,ELECTRI,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012023509 NA 4 N 50105598 250/FT
507 P1 4 M TUBE,METALLIC, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4710 002774624 NA 4 N 50105311 12/FT
508 F2 4 M COUPLING, COUPLING, 1-
1/2"IPS, SLIP, SILVER
BRAZING,
BRONZE, 400PSI, WITH RING,
MIL-F-1183, M1183/3-27A,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9C 4730 LL4465246 NA 4 N 50137464 3/EA
509 34 1 M CABLE,SPECIAL PURPO,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012029528 NA 4 N 50105576 30/FT
510 2 5 M TAPE,LUMINOUS, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9390 014626832 NA 4 N 50105339 1/RO
511 7 3 M BAR,METAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 001891556 NA 4 N 50105364 10/FT
512 5 6 M SHEET,ME, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9535 002326869 NA 4 N 50105234 2/SH
513 15 2 M CABLE,POWER,ELECTRI,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012028463 NA 4 N 50105605 400/FT
FOUO
M-3
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
514 2 6 M DIFFUSER, DIFFUSER, ONE-
PIECE CORE, NO-MARGIN,
WITH OPTIONAL SHOCK &
VIRATION CONSTRUCTION,
STYLE: 31, SIZE: 12” X 9",
MARGIN: NONE, MODULE:
NONE, ACCESSORIES: NONE,
ROUND NECK SIZE: 00, MATL:
ALUMINUM, FINISH: WHITE,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4220 LL9813887 NA 4 N 50167508 2/EA
515 3 6 M SHEET,ME, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9535 002326866 NA 4 N 50105220 2/SH
516 F3 4 M COUPLING,PIPE, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
3B 4730 012145200 NA 4 N 50105316 1/EA
517 9 7 M SCREW,CA, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5305 015329137 SX NA 4 N 50105248 1/HD
518 12 7 M ANGLE,ST, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002774911 NA 4 N 50105256 10/FT
519 13 7 M RIVET,BLIND, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5320 015332197 NA 4 N 50105349 1/PG
520 14 7 M BAR,METAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 001891558 NA 4 N 50105351 5/FT
521 3 7 M PRINTER STAND, PRINTER
STAND, SIZE: 36" W X 30" D X
27" H, MATL: STEEL, COLOR:
BLACK, TOP LAMINATE:
WILSONART, AMBER CHERRY
7919, ***** APPROVED FOR
SHIPBOARD USE AS DEFINED
NAVSEA DWG: 613-8894013.
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 2090 LL9813888 NA 4 N 50167478 1/EA
522 6 7 M EXTINGUISHER,FIRE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4210 013882636 NA 4 Y 50105342 1/EA
523 7 8 M BAR, METAL, FLAT, BAR,
METAL, FLAT, SPEC: ASTM
A1011 CS TYPE B, THK: 1/8",
WIDE: 3", MATL: STEEL,
QTY: 10 FT (ONE
CONTINUOUS LENGTH
REQUIRED) X 1 EA,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 LL9813889 NA 4 N 50167482 10/FT
524 4 8 M SHEET,METAL, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9B 9515 008274474 NA 4 N 50105629 2/SH
FOUO
M-4
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
525 5 8 M BLIND RIVET, BLIND RIVET,
SIZE: 3/16" DIA, HEAD TYPE:
DOME, HEAD SIZE: 0.65" DIA X
0.092" H, GRIP RANGE: 0.126" -
0.25", RIVET & MANDREL MATL:
ALUMINUM, UI: PACKAGE (100
EA),
DO NOT CROSS NSN: 5320-01-
498-8497 (DIRECTION BY DWG
604-8894011, REMARKS OF
ITEM NO.5),
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-14
9B 5320 LL9310088 NA 4 N 50167487 3/PG
526 8 7 M ANGLE,STRUCTURAL, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002774912 NA 4 N 50105344 10/FT
527 10 7 M NUT,SELF-LOCKING,HE,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 015353265 NA 4 N 50105346 1/HD
528 11 7 M LOCKER,CLOTHING, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9Q 7125 016665404 NA 4 N 50105608 6/EA
529 F5 4 M CLOTH,PL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 8305 001487363 NA 4 N 50105131 1/RO
530 F1 9 M PLATE,ME, SIZE: 1 FT X 1 FT,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9515 001533184 NA 4 N 50105297 1/SF
531 F2 9 M CAP,PIPE, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4730 005951281 NA 4 N 50105319 1/EA
532 F3 9 M CAP,PIPE, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4730 005951279 NA 4 N 50105321 1/EA
533 5 10 M CONNECTO, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5935 010123080 NA 4 N 50105161 2/EA
534 9 10 M CABLE,POWER,ELECTRI,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012022796 NA 4 N 50105325 40/FT
535 6 8 M DOOR,METAL JOINER, DOOR,
METAL JOINER, HONEYCOMB
CORE, RIGHT HAND, WITH
LOCK SET, CLOSER & KICK
OUT PANEL, WITHOUT FIXED
LIGHT & MOUNT HOLE,
DWG: 804-4629248 REV.B
TYPE-E ELEVATION 4-D,
CLEAR OPENING SIZE: 26” W X
74" H, 1” SILL
HINGE: CONTINUOUS HINGE,
9B 2040 LL9813908 NA 4 N 50397424 1/EA
536 2 1 M ROPE,FIBROUS, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4020 011876317 NA 4 N 50105367 1/EA
537 3 1 M JUNCTION, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 5975 001948877 NA 4 N 50105275 1/EA
FOUO
M-5
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
538 29 1 M HEAT DETECTOR, HEAT
DETECTOR, 302 SERIES,
MOISTURE/DUST PROOF,
TOTAL LENGTH: 4-1/8", BASE
DIAMETER: 2", TEMPARATURE
ACCURACY: 135 DEGF,
MODEL NO. KF302AW135,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6340 LL9813427 NA 4 N 50167483 1/EA
539 29 1 M ADAPTER PLATE, ADAPTER
PLATE FOR RATE
COMPENSATING, VERTICAL
MOUNT DETECTORS, MODEL
NO. KF-APP,
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6350 LL9813428 NA 4 N 50167484 1/EA
540 31 1 M COVER,JUNCTION BOX,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001536775 NA 4 N 50105376 1/EA
541 F1 4 M PLATE,ME, SIZE: 1 FT X 1 FT,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9515 001533184 NA 4 N 50105292 1/SF
542 10 10 M CABLE,POWER,ELECTRI,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012019499 NA 4 N 50105329 40/FT
543 2 2 M LIGHT,WARNING,EXIT S,
LIGHT, WARNING, EXIT SIGN,
ILLUMINATED, LED, WITH
WHITE CASE, RED
LETTERING, HIGH-OUTPUT NI-
CAD BATTERY, LESS LAMP
HEADS, HFPA 101.
DO NOT CROSS NSN6210-01-
686-5194(OPTIONAL BATTERY
& LESS LAMP
HEADSREQUIRED).
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6210 LL9812481 NA 4 N 51067564 1/EA
544 4 2 M SWITCH,TOGGLE, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5930 008930034 NA 4 N 50105332 2/EA
545 7 7 M MOUNTING BRACKET, FIRE
EXTINGUISHER MOUNTING
BRACKET, HEAVY DUTY, WITH
METAL RETENTION STRAP,
FOR 7.0" THRU 8.0" DIA
EXTINGUISHER BOTLE,
MODEL NO: 811, SIZE: 8" W X
12" D X 18" H, MATL: STEEL,
COLOR: BLACK,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 4210 LL9813883 NA 4 N 50167506 1/EA
FOUO
M-6
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
546 5 3 M BAR,METAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 005962323 NA 4 N 50105362 10/FT
547 6 3 M BEAM,STRUCTURAL, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002780935 NA 4 N 50105627 20/FT
548 4 6 M INSULATI, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9Q 5640 008096312 NA 4 N 50105227 4/EA
549 6 6 M SHEET,METAL, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9535 002042286 NA 4 N 50105337 1/SH
550 10 2 M TERMINAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5940 002155959 NA 4 N 50105195 1/EA
551 16 2 M CABLE,POWER,ELECTRI,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012019495 NA 4 N 50105336 15/FT
552 15 7 M BAR,META, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 001891565 NA 4 N 50105263 10/FT
553 17 7 M WELD STUD, WELD STUD,
FULLY THREADED, OVERALL
LG: 1/2", HREAD SIZE: NO.10-
24UNC-2A, BASE SIZE: 0.448"
DIA X 0.068" THK,
MATL: STEEL, UI: PACKAGE
(100 EA),
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5307 LL9813886 NA 4 N 50167489 1/PG
554 6 2 M SWITCH,TOGGLE, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5930 009849971 NA 4 N 50105335 2/EA
555 7 2 M PLATE,WA, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002807921 NA 4 N 50105181 2/EA
556 5 1 M COVER,JU, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002810056 NA 4 N 50105280 1/EA
557 6 1 M CONNECTOR, EMT,
CONNECTOR, INSULATED,
WITH SET SCREW, USE FOR
ELECTRICAL METALLIC
TUBING (EMT) CONDUIT,
CONDUIT SIZE: 3/4", MATL:
STEEL, FINISH: ZINC PLATED,
50EA/PG (INNER), 100EA/PG
(GSA).
NSN: 5975-01-408-0240 (NO
MANAGEMENT DATA),
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 LL9813880 NA 4 N 50997495 1/EA
558 9 1 M STRAP,RETAINING, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 5340 009646279 NA 4 N 50105369 25/EA
FOUO
M-7
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
559 11 1 M STUD,WELDING, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5307 012650519 NA 4 N 50105370 10/EA
560 17 1 M STUD,WELDING, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5307 002571530 NA 4 N 50105372 30/EA
561 28 1 M CONDUIT,METAL,RIGID,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001781217 NA 4 N 50105373 10/LG
562 31 1 M JUNCTION BOX, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001536397 NA 4 N 50105375 1/EA
563 34 1 M CABLE,SPECIAL PURPO,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6145 012029528 NA 4 N 50105378 30/FT
564 3 2 M JUNCTION, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002845827 NA 4 N 50105175 4/EA
565 5 2 M PLATE,WALL,ELECTRIC,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 005014924 NA 4 N 50105334 1/BX
566 8 2 M JUNCTION, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001948877 NA 4 N 50105185 8/EA
567 9 2 M COVER,JU, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002810056 NA 4 N 50105191 8/EA
568 7 6 M SOUND CO, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9Q 5640 013837815 NA 4 N 50105243 3/SH
569 6 10 M JUNCTION, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002845827 NA 4 N 50105166 2/EA
570 7 10 M PLATE,WA, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001881164 NA 4 N 50105170 2/EA
571 3 5 M SIGNS,REFLECTIVE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 7690 014626269 NA 4 N 50105340 1/PG
572 16 7 M HOOK RACK, HEAVY DUTY
HOOK RACK, OVERALL SIZE:
48" W X 7-3/4" H X 2-7/8" D, NUMBER OF HOOKS: 5,
CAPACITY: 300 LBS,
MATL: ZINC PLATED STEEL,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 7195 LL9813885 NA 4 N 50167488 2/EA
573 18 7 M NUT,SELF-LOCKING,HE,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 012902196 NA 4 N 50105357 25/EA
574 2 3 M BAR,METAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 9510 001891590 NA 4 N 50105361 1/FT
FOUO
M-8
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
575 4 3 M SHEET, M, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9515 002375413 NA 4 N 50105302 1/SH
576 6 3 M BEAM,STRUCTURAL, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002780935 NA 4 N 50105628 20/FT
577 1 8 M SHEET,ME, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9535 002326869 NA 4 N 50105268 5/SH
578 2 8 M SHEET, M, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9515 002375413 NA 4 N 50105306 1/SH
579 3 8 M SHEET,METAL, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9515 012659078 NA 4 N 50105365 1/SH
580 1 10 M JUNCTION, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001948877 NA 4 N 50105138 8/EA
581 2 10 M COVER,JU, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 002810056 NA 4 N 50105143 8/EA
582 3 10 M CIRCUIT BREAKER, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5925 005015051 NA 4 N 50935570 2/EA
583 4 10 M YOKE,CIR, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5925 002020938 NA 4 N 50105154 1/EA
584 8 6 M WOVEN WIRE CLOTH, WOVEN
WIRE CLOTH. LIGHTWEIGHT
ALUMINUM WIRE CLOTH 2 X 2
MESH, .063" WIRE DIAMETER,
24" X 24", OPENING SIZE:
0.437".
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5335 LL6978309 NA 4 N 51327479 1/EA
585 25 11 M EMT CONDUIT,STL, EMT
CONDUIT, TRADE SIZE: 1",
SIZE: 1.163" OD X 0.057" WALL
THK X 10 FT LG, MATL:
ELECTROPLATED STEEL,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 LL9814048 NA 4 N 50717538 4/EA
586 26 11 M CONNETOR BOX, CONNETOR
BOX, SINGLE GANG OUTLET
BOX, WITH MOUNTING STUD,
2" X 4", STEEL, 6 KNOCKOUTS,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 5935 LL9601606 NA 4 N 50917511 2/EA
FOUO
M-9
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
587 36 11 M CABLE TRAY SUPPORT,
CABLOFIL WIRE MESH CABLE
TRAY SUPPORT, CENTER
HANGER, SIZE: 6" (5.66") LG,
MATL: STEEL, FINISH: PRE-
GLAVANIZED,
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5340 LL9814050 NA 4 N 50747417 10/EA
588 M COUPLING,TUBE, 1-1/2", CU-NI
90/10, SW
ORIG: C234 S. YAMASHITA
070-7787-2035
ODERED FOR KTR
9B 4730 014645439 NA 4 N 50805174 3/EA
589 M COUPLING, REDUCING,
COUPLING, REDUCING,
SOCKET WELD, SIZE: 1-1/2" X
1/2" IPS, MATL: CU-NI 90/10,
PRESSURE: 400 PSI, DWG:
803-6397430, PREMIER COPPER P/N:
99150296
ORIG: C234 S. YAMASHITA
070-7787-2035
ODERED FOR KTR
9B 4730 LL4739080 NA 4 N 50807418 1/EA
590 6 11 M CONNECTOR,EMT,
CONNECTOR, INSULATED,
WITH SET SCREW, USE FOR
ELECTRICAL METALLIC
TUBING (EMT) CONDUIT,
CONDUIT SIZE: 3/4", MATL:
STEEL, FINISH: ZINC PLATED,
50EA/PG (INNER), 100EA/PG
(GSA).
NSN: 5975-01-408-0240 (NO
MANAGEMENT DATA),
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 LL9813880 NA 4 N 50997496 1/EA
591 14 11 M COUPLING, NUT, THD,
COUPLING NUT, THREADED,
FEMALE, 3/8 INCH, STEEL,
ELECTRO ZINC, 100 EA/PG,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5325 LL4598837 NA 4 N 50747420 1/PG
592 16 11 M SPLICE WASHER KIT, H,
SPLICE WASHER KIT,
HANGER, STEEL, BX = 50 EA,
NSN: 5340-01-665-9126 (NO
MANAGEMENT DATA),
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5340 LL4598885 NA 4 N 50747421 1/BX
593 15- B
11 M BAR,METAL, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9510 002615729 NA 4 N 50845091 2/FT
594 15- B
11 M NUT,SELF, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 5310 002416604 NA 4 N 50845094 10/EA
FOUO
M-10
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
595 20 11 M BRACKET,MOUNTING,
BRACKET, MOUNTING,
CENTER HANGER, CABLE
TRAY SUPPORT, 2 INCH
WIDTH, ASTM A 653,
PREGALVANIZED.
USED FOR CABLE TRAY
CF54/50EZ,
***GSA ADVANTAGE
AVAILABLE***
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5340 LL9601603 NA 4 N 50747416 15/EA
596 M RUBBER S, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5330 013717183 NA 4 N 50625057 20/FT
597 1 3 M SCUTTLE,MARINE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
3B 2040 007254519 NA 4 N 51575233 1/EA
598 M TAPE,TEX, MATERIAL ORDER
FOR CONTRACTOR
ORIG: C231A Y. AOKI, 243-4503
9B 8315 002671633 NA 4 N 50785089 15/RO
599 M CAP, ORDERED FOR
CONTRACTOR
ORIG: C231A Y. AOKI, 243-4503
9B 5340 LL4601470 NA 4 N 50787449
1100/E
A
600 M ADHESIVE, ORDER FOR
COTRACTOR
ORIG: C231A Y. AOKI, 243-4503
9B 8040 002738708 NA 4 Y 50785093 8/GL
601 21 11 M CABLE TRAY, CABLE TRAY, 2"
H X 2" W X 10 FEET LONG,
STEEL, ELECTRO ZINC,
***GSA ADVANTAGE
AVAILABLE***
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5340 LL4598886 NA 4 N 50747415 7/EA
602 30 11 M EMT CONDUIT COUPLING,
EMT CONDUIT COUPLING,
DWG: 302-7583920 REV. A
ITEM NO. 47, TRADE SIZE: 1",
MATL: STEEL, 15EA/BX,
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 LL9814015 NA 4 N 50717537 1/BX
603 1 11 M POLY LINE, POLY LINE, 240 LB
BREAKING STRENGTH, BOX =
5200 FEET (1585M), READY-
TO-USE, PRE-PUNCHED HOLE
IN LID WITH RESEALABLE
CAP.USE WITH POWER
FISHING SYSTEMS DIRECTLY
FROM THE CONTAINER.
RESISTS TANGLING WHEN
DISPENSING. ROT AND
MILDEW RESISTANT,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9B 4020 LL4651086 NA 4 N 50717535 1/BX
FOUO
M-11
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
604 15- B
11 M SHEET,ME, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9535 002326865 NA 4 N 50845090 1/SH
605 10 11 M WASHER,FLAT, WASHER,
FLAT, 3/8 INCH, STEEL,
ELECTRO ZINC, 100 EA/PG,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 LL4598834 NA 4 N 50747419 1/PG
606 12 11 M THREADED ROD, THREADED
ROD, 3/8 INCH, THREAD
PITCH: 16, STEEL, ELECTRO
ZINC, 6 FEET LONG.
NSN: 5306-01-674-5954 (NO
MANAGEMENT DATA),
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5306 LL4598835 NA 4 N 50747413 22/EA
607 15 11 M SPLICE, HANGER WITH ,
SPLICE, HANGER WITH TOOL,
STEEL, BX = 50 EA, NSN: 5975-
01-657-2644 (NO
MANAGEMENT DATA),
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 LL4598884 NA 4 N 50747414 1/BX
608 18 11 M NUT,SELF, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 002416604 NA 4 N 50585138 20/EA
609 M INSULATION BLOCK,TH,
ORDERED FOR CONTRACTOR
ORIG:C231A Y. AOKI, 243-4503
9Q 5640 008096312 NA 4 N 50935826 5/BX
610 M INSULATION BLOCK,TH,
ORDER FOR CONTRACTOR
ORIG: C231A Y. AOKI, 243-4503
9Q 5640 008096315 NA 4 N 50935637 9/BX
611 M TAPE,TEX, MATERIAL ORDER
FOR CONTRACTOR
ORIG: C231A Y. AOKI, 243-4503
9B 8315 002671632 NA 4 N 50785087 15/RO
612 32 11 M PIPE HANGER, KEY LOCK PIPE
HANGER, WELD MOUNT, WITH
GROMMET/LINER, PIPE SIZE:
1" IPS, WELD MOUNT SIZE: 1-
1/2" W X 1/4" THK X 18” LG,
HANGER MATL: STEEL, LOCK
KEY MATL: STAINLESS,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4730 LL9814266 NA 4 N 51907418 4/EA
613 8 1 M COUPLING,ELECTRICAL,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5975 001008827 NA 4 N 50725011 25/EA
614 4 11 M PIPE,METALLIC, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9B 4710 008925913 NA 4 N 50585136 5/FT
FOUO
M-12
SHIP: YR-85 CHG/VER: 0/0
MATERIAL LIST
ITEM
NO.
PC
NO.
REF
NO.
M
C DESCRIPTION
STOCK
NUMBER
GENERIC
MATL
TYPE LVL QA
HAZ
MAT
DOC
NO.
QTY
REQD/
UNIT
QTY
USED/
UNIT
615 7 11 M NUT, NUT, 3/8 INCH STEEL,
ELECTRO ZINC, 100 EA/PG,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5310 LL4598833 NA 4 N 50747418 1/PG
616 6 3 M BEAM,STRUCTURAL, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002780935 NA 4 N 51575165 20/FT
617 6 3 M BEAM,STRUCTURAL, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 9520 002780935 NA 4 N 51575169 20/FT
618 15- B
11 M INSULATI, ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5970 002957658 NA 4 Y 50845089 1/GL
619 37 11 M ADAPTER PLATE, ADAPTER
PLATE FOR RATE
COMPENSATING, VERTICAL
MOUNT DETECTORS, MODEL
NO. KF-APP,
**GSA ADVANTAGE
AVAILABLE**
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 6350 LL9813428 NA 4 N 50717525 1/EA
620 1 3 M SCUTTLE,MARINE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
3B 2040 007254519 NA 4 N 51575234 1/EA
621 15- B
11 M SCREW,MACHINE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 5305 000711318 NA 4 N 50845093 10/EA
622 35 11 M PIPE HANGER, KEY LOCK PIPE
HANGER, WELD MOUNT, WITH
GROMMET/LINER, PIPE SIZE:
3/4" IPS, WELD MOUNT SIZE:
3/4" W X 1/4" THK X 18” LG,
HANGER MATL: STEEL, LOCK
KEY MATL: STAINLESS,
ORDER FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 4730 LL9814265 NA 4 N 51907417 6/EA
623 3 5 M SIGNS,REFLECTIVE, ORDER
FOR KTR
ORIG: C226 H.SHIMIZU, 080-
9350-1431
9B 7690 014626269 NA 4 N 60295228 1/PG
624 145-
12 M SIGNS,RE, MAT JML 9B 7690 014626269 NA 4 N 60295220 1/PG
625 2 5 M TAPE,LUMINOUS, ORDER FOR
KTR
ORIG: C226 H.SHIMIZU, 080-
9B 9390 014626832 NA 4 N 60655291 1/RO
FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____
☐ NUCLEAR APPENDIX "D"
DEFICIENCY FORM
☐ NON-NUCLEAR
1. SHIP/HULL NO.: 2a. DL or DR No.
(Circle One)
2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:
YR-85 S/A YR-1116D AY A 1
4a. ICN: 4b. KEY OP: 5. LOC SPACE/LVL: FRAME: P/S/C: 6. CAUSED BY:
38HVC60001 A02
7. DESCRIPTION:
8. ORIGINATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:
9. CORRECTIVE ACTION:
10. EVALUATOR: NAME: BADGE: SHOP/CODE: DATE: PHONE NO.:
FOR NON-NUCLEAR USE ONLY
11. RFD/RFW REQ’D ☐ LAR REQ'D ☐
ILS MOD REQ’D ☐
SRD/PLAN REV REQ'D ☐
DWG NO.: _____________________ S/A NO.: ___________________
12. ISOLATION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.:
SATISFACTORY:
13. SUBSAFE OQE RECORD? SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.
YES ☐ NO ☐
14. CORRECTIVE ACTION SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.
COMPLETE:
15. INSPECTION REQ’D? INSPECTION COMPLETE/SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.
_________:YES ☐ NO ☐
16. RECORDS REVIEW SIGN: BADGE: SHOP/CODE: DATE: PHONE NO.
COMPLETE (DR ONLY)
DL’s ISSUED
(DR ONLY)
FOUO: Public availability to be determined under 5 USC 552 SHEET_____OF_____
☐ NUCLEAR Deficiency Form Continuation Sheet ☐ NON-NUCLEAR
1. SHIP/HULL NO.: 2a. DL or DR No.
(Circle One) 2b. REVISION: 3a. COMPONENT NAME: 3b. TYPE: 3c. PHASE: 3d. REPEAT:
YR-85 S/A YR-1116D AY A 1
DELETED
38HVC60001A02
ENGRG INST
ENCLOSURE-01 Sheet 1 of 1
38HVC60001A02 ENCLOSURE-02
38HVC60001A02 ENCLOSURE-02
COMUSFLTFORCOMINST 4790.3 REV D CHG 5
13 JUN 2025
38HVC60001A02 ENCLOSURE-03-1 TOTAL 1
SHOP TEST RECORD Page 1 of 1
QA FORM 28 Planning must fill in blocks identified by a prior to issuing
1. SHIP HULL NO. 2. JCN 3. LWC/SHOP 4. CWP/REC SER NO. 5. SYSTEM/COMPONENT/ROTATABLE POOL SER NO.
USS BARGE YR85 Y852-4027 KTR N/A Potable Water System Piping
6. REFERENCES: TEST REF (E.G., MS, TECH MAN) & OTHER REFS (E.G., VLV DWG) 7. TEST GAGE RANGE /INSTRUMENT USED SERIAL NO. CAL DUE DATE 8. RELIEF VLV SET POINT
A. S9086-RK-STM-010/CH-505 Rev. 6
B. DWG 509-8895112 Rev. “-’’
C.
D.
9. TEST REQUIREMENTS & RESULTS
TEST TYPE KEY H = STRENGTH AND POROSITY/ELEVATED PRESSURE TEST J = MECHANICAL JOINT TIGHTNESS ST = SEAT TIGHTNESS OP = OPERATIONAL O = OTHER
(SPECIFY): ______________________
TE
ST
T Y
PE
(S
EE
K
EY
) PARAGRAPH
DESCRIBING
VALVE POSITION
AND POINT OF
ENTRY
REF
LTR
GAGE
USED
(LTR
FROM
BLK 7)
REQUIRED
MEDIUM
MEDIUM
USED
REQUIRED
PRESSURE
ACTUAL
PRESSURE
MINIMUM
DURATION
ACTUAL
DURATION
ALLOWED
LEAKAGE
ACTUAL
LEAKAGE SAT/UNSAT SIGNATURE, BADGE NO. & DATE
H 5.3.4 for 1.3.5 A,B Clean Fresh Water 135 PSIG 30 minutes None
H 5.3.4 for 1.3.6 A,B Clean Fresh Water 135 PSIG 30 minutes None
10. REMARKS. (CRAFTSMAN/QAI SUBMIT A DF TO RESOLVE UNSAT DATA)
11. QA INSPECTOR/SHOP SUPERVISOR SIGNATURE/BADGE NO. (RECORD
REVIEWED FOR FINAL ACCEPTANCE)
DATE 12. QAS SIGNATURE/BADGE NO. (RECORD HAS BEEN REVIEWED FOR
COMPLETENESS)
DATE
File details come from the government source that posted it. Updated .