Wayfinding Sign Fabrication and Installation Location Plans
This file comprises design intent location plans for the Town of Farragut wayfinding signage fabrication and installation project, prepared by Guide Studio, Inc., dated September 26, 2024. The document establishes the visual design framework for Phase 1 of a comprehensive town-wide wayfinding program intended to enhance aesthetic qualities, attract visitors, support business owners, and increase community connectivity. The location plans delineate multiple zones (A through I, TC-1 through TC-4) across Farragut where various sign types will be installed, including post-mounted street signs (L1a), mast arm street signs (L1b/Lb.1), permanent banners (Q1), gateway signs, and a plaza arch. The selected sign contractor must be responsible for final design engineering, material selection, fabrication, and installation methodologies. Specific locations for certain sign types remain to be determined (TBD), with final quantities outlined in an accompanying message schedule.
The general notes establish comprehensive responsibilities for the sign contractor, including structural engineering design and stamped drawings for all gateway signs and plaza arch structures, with the contractor's structural engineer required to be licensed in Tennessee. The contractor must conduct field verification of all sign locations prior to fabrication, coordinate with the Town regarding utility locations and permit acquisition, obtain all required field inspection approvals, and verify and adjust masonry dimensions as needed. The contractor assumes responsibility for material selection, cleaning and sealing of masonry, and submission of brick, stone, and mortar samples for approval. All sign messages and spellings shown in the design intent drawings are not final and require submission for Town review and approval. The electronic files provided are design intent documents only and are not construction documents; the contractor bears all risk associated with their use and must adhere to performance specifications and design intent documents provided separately.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Wayfinding Signs - Phase 1
Town of Farragut
DESIGN INTENT LOCATION PLANS | TFT1842 | SEPTEMBER 26, 2024
©Guide Studio, Inc. guidestudio.com
A
B
I
E
F G
D
TC-4
TC-2 TC-3
TC-1
C
H date 09.26.24 contact project TFT1842 phase Design Intent - Phase 1 NOT FOR CONSTRUCTION These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 1design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Location Plans Overall Town Reference
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the attached Performance Specifications and Design Intent Documents.
date 09.26.24 contact project TFT1842 phase Design Intent - Phase 1 NOT FOR CONSTRUCTION These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 2design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Location Plans
Zone B
Zone A
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 3design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Location Plans
Zone DZone C
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 4design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone E
Zone F
Location Plans
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 5design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone H
Location Plans
Zone G
Zone I
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
Sign Type L1a (post-mounted street sign) & L1b/Lb.1 (mast arm street sign) are represented by (1) symbol each. See Message Schedule for quantities. Locations TBD.
Sign Type Q1 is a series of permanent banners represented by
(1) symbol. See Message Schedule for quantities. Locations TBD.
Sign Type Q1 is a series of permanent banners represented by
(1) symbol. See Message Schedule for quantities. Locations TBD.
date 09.26.24 contact project TFT1842 phase Design Intent - Phase 1 NOT FOR CONSTRUCTION These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 6design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone TC-1
Location Plans
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
Sign Type Q1 is a series of permanent banners represented by
(1) symbol. See Message Schedule for quantities. Locations TBD.
date 09.26.24 contact project TFT1842 phase Design Intent - Phase 1 NOT FOR CONSTRUCTION These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 7design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone TC-2
Location Plans
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
Sign Type Q1 is a series of permanent banners represented by
(1) symbol. See Message Schedule for quantities. Locations TBD.
date 09.26.24 contact project TFT1842 phase Design Intent - Phase 1 NOT FOR CONSTRUCTION These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 8design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone TC-3
Location Plans
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the
These drawings and notes are for the sole purpose of expressing visual design intent and are not intended for actual fabrication purposes. Sign Contractor accepts total responsibility for final material selection, fabrication and installation methods. Sign messages and spellings shown within the these drawings are not to be relied upon for fabrication. Sign Contractor must submit final messages and sign face layouts for review and approval by the user. Electronic files are not construction documents and cannot be relied upon as identical to construction documents because of changes or errors induced by translation, transmission, or alterations while under the control of others. Use of information contained in the electronic files is at the user’s sole risk and without liability to Design Professional and its consultants. Refer to provided performance specifications for details on designer expectations of the Sign Contractor and fabrication process. Copyright © Guide Studio, Inc. All rights reserved.
sheet pm G. Gerken Town of Farragut 9design K. Fromet/J. Wilhelm Sign Systemguidestudio.com
Zone TC-4
Location Plans
GENERAL NOTES
1. Sign contractor shall be responsible for design and engineering of supports, anchors and miscellaneous steel or metal required� for installation.
2. The sign contractor must submit stamped engineering drawings for all gateway signs and plaza arch, plus any additional signs deemed necessary by Town requirements. The sign contractor’s structural engineer shall be licensed in� the state of Tennessee and certify all connections and support details.
3. Isolate dissimilar materials as required.
4. Field dimensions shall be taken by the sign contractor �prior to preparation of shop drawings and fabrication where� possible. It is the responsibility of the sign contractor to site �verify all sign locations for accuracy, fit, and potential �obstacles. Sign contractor shall notify appropriate person(s) �of any issues, discrepancies and potential obstacles per the� attached Performance Specifications, contract or specified� communication process.
5. It is the responsibility of the sign contractor to verify the locations of underground utilities before digging.
6. Sign contractor must obtain all permits and field inspection �approvals necessary to complete work per Town requirements. All sign locations need to be located and staked by sign contractor and approved by city prior to installation.
7. Masonry dimensions are approximate; sign contractor to verify� and adjust as needed. Final dimensions must appear on shop �drawings for review and approval.
8. Sign contractor must clean and seal masonry to prevent moisture, discoloration and other defects due to weather and environmental conditions.
9. Sign contractor must submit brick, stone, and mortar samples �for review and approval.
10. Sign contractor shall follow any additional requirements presented in the