POM Job Order Contracting (SATOC) 2503
SECTION TABLE OF CONTENTS
DIVISION 10 - SPECIALTIES
SECTION 10 11 00
VISUAL DISPLAY UNITS
08/20
PART 1 GENERAL
1.1 REFERENCES
1.2 DEFINITIONS
1.3 SUBMITTALS
1.4 CERTIFICATIONS
1.4.1 Indoor Air Quality
1.4.1.1 Indoor Air Quality for Visual Display Products
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 MATERIALS
2.1.1 Porcelain Enamel
2.1.2 Cork
2.1.2.1 Colored Cork
2.1.2.2 Natural Cork
2.1.3 Non-Woven Fabric
2.1.4 Vinyl Wall Covering
2.1.5 Aluminum
2.1.6 Hardwood
2.1.7 Glass
2.1.7.1 Glass with Interlayer Color Coating
2.1.7.2 Magnetic Glass
2.2 PRESENTATION BOARD
2.3 MARKERBOARD
2.3.1 Porcelain Markerboard
2.3.2 Glass Markerboards with Interlayer Color Coating
2.4 TACKBOARDS
2.4.1 Cork
2.4.2 Vinyl Covered
2.4.3 Fabric Covered
2.5 BOARD CASE
2.6 DISPLAY TRACK SYSTEM
2.7 INTERACTIVE WHITEBOARDS
2.8 PROJECTION SCREEN
2.9 COLOR
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
3.2 INSTALLATION
3.3 CLEANING
-- End of Section Table of Contents --
SECTION 10 11 00 Page 1
SECTION 10 11 00 Page 2
SECTION 10 11 00
VISUAL DISPLAY UNITS
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
ASTM INTERNATIONAL (ASTM)
ASTM B221 (2021) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials
ASTM F148 (2013) Binder Durability of Cork Composition Gasket Materials
ASTM F152 (1995; R 2009) Tension Testing of Nonmetallic Gasket Materials
ASTM F793/F793M (2020) Standard Classification of Wall Coverings by Use Characteristics
CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)
CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers
SCIENTIFIC CERTIFICATION SYSTEMS (SCS)
SCS SCS Global Services (SCS) Indoor Advantage
UNDERWRITERS LABORATORIES (UL)
UL 2818 (2013) GREENGUARD Certification Program For Chemical Emissions For Building
SECTION 10 11 00 Page 3
Materials, Finishes And Furnishings
1.2 DEFINITIONS
The term visual display unit when used herein includes presentation boards, markerboards, tackboards, board cases, display track systems, horizontal sliding units, copyboards, interactive whiteboards, and projection screens; submit manufacturer's descriptive data and catalog cuts plus manufacturer's installation instructions, and cleaning and maintenance instructions. Provide visual display units from manufacturer's standard product line. Submit certificate of compliance signed by Contractor attesting that visual display units conform to the requirements specified.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Placement Schedule; G
SD-03 Product Data
Visual Display Unit; G
Projection Screen; G
SD-04 Samples
Aluminum; G
Hardwood; G
Porcelain Enamel; G
Cork; G
Fabric; G
Vinyl Wall Covering; G
Glass; G
SD-07 Certificates
Indoor air quality for markerboards; S
Indoor air quality for tackboards; S
Indoor air quality for projection screen; S
Certificate of Compliance
SECTION 10 11 00 Page 4
SD-08 Manufacturer's Instructions
Manufacturer's Cleaning Instructions
Manufacturer's Printed Installation Instructions
SD-10 Operation and Maintenance Data
Visual Display Units, Data Package 1; G
1.4 CERTIFICATIONS
1.4.1 Indoor Air Quality
1.4.1.1 Indoor Air Quality for Visual Display Products
Provide products certified to meet indoor air quality requirements by UL 2818 (Greenguard) Gold, SCS Global Services Indoor Advantage Gold or provide certification or validation by other third-party program that products meet the requirements of this Section. Provide current product certification documentation from certification body. When product does not have certification, provide validation that product meets the indoor air quality product requirements cited herein.
1.5 DELIVERY, STORAGE, AND HANDLING
Deliver materials to the building site in the manufacturer's original unopened containers and store them in a clean dry area with temperature maintained above 50 degrees F. Stack materials according to manufacturer's recommendations. Allow visual display units to acclimate to the building temperature for 24 hours prior to installation.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective materials and workmanship for period of one year from date of final acceptance of the work.
PART 2 PRODUCTS
2.1 MATERIALS
For each type, submit a section of core material and backing showing the lamination of porcelain enamel coating on steel, colored cork, natural cork, woven fabric, non-woven fabric, or vinyl wall covering, as applicable. Submit a sample of hardwood, plastic laminate finish, or glass type, as applicable. Provide minimum 4 by 4 inch samples, or larger, showing range of color.
Submit manufacturers' descriptive product data for each type of visual display unit indicated. Include manufacturers' literature, finishes, profiles and thicknesses of materials.
Submit manufacturers' operations and maintenance data for each type of visual display unit in accordance with Section 01 78 23 OPERATIONS AND
MAINTENANCE DATA.
SECTION 10 11 00 Page 5
2.1.1 Porcelain Enamel
Provide markerboard writing surface composed of porcelain enamel fused to a nominal 28 gauge thick steel, laminated to a minimum 1/4 inch thick core material with a steel or foil backing sheet. Writing surface must be capable of supporting paper by means of magnets. Markerboard surface for display track system may be a powder paint dry erase surface adhered to a nominal 18 gauge thick steel.
2.1.2 Cork
Provide a continuous resilient sheet made from soft, clean, granulated cork relatively free from hardback and dust and bonded with a binder suitable for the purpose intended; wearing surface to be free from streaks, spots, cracks or other imperfections that would impair its usefulness or appearance. Provide seasoned material and a clean cut made not less than 1/2 inch from the edge and must show no evidence of soft sticky binder.
2.1.2.1 Colored Cork
Provide colored cork composed of pure cork and natural color pigments that are combined under heat and pressure with linseed oil. Colored cork must be colored throughout and be washable. The burlap backing must be deeply imbedded and keyed to the work sheet being partially concealed in it and meeting the requirements of ASTM F148.
2.1.2.2 Natural Cork
Provide a light tan natural cork composed of a single layer of pure grain natural cork without backing or facing. Cork sheets must have a tensile strength of not less than 40 psi when tested in accordance with ASTM F152.
2.1.3 Non-Woven Fabric
Provide a non-woven, hooktape compatible fabric with a backed 100 percent polyester fiber content and 11 oz. plus or minus 0.5 oz. per lineal yard for 60 inch wide fabric minimum total weight. Fabric must have a Class A flame spread rating of 0-50 and smoke development rating of 0-450 in accordance with ASTM E84.
2.1.4 Vinyl Wall Covering
Provide vinyl wall covering conforming to ASTM F793/F793M , Category V with a Class A flame spread rating of 0-50 and smoke development rating of 0-450 in accordance with ASTM E84.
2.1.5 Aluminum
Provide a minimum 0.06 inch thick, 6063-T5 or 6063-T6 aluminum alloy frame extrusion conforming to ASTM B221. Exposed aluminum must have anodized, satin finish. Use straight, single lengths wherever possible and keep joints to a minimum. Provide mitered corners with a hairline closure.
Submit sections of frame, map rail, and marker rail, and two map hooks.
2.1.6 Hardwood
Provide exposed oak, walnut or mahogany hardwood with manufacturer's standard durable factory-applied stain and lacquer finish for frames, SECTION 10 11 00 Page 6 cabinets, and cases.
2.1.7 Glass
Provide tempered glass in accordance with ANSI Z97.1 and ASTM C1048, Kind FT (fully tempered), Condition A (uncoated), Type I, Class I (clear), thickness as specified.
2.1.7.1 Glass with Interlayer Color Coating
Provide glass markerboard writing surface composed of tempered, low-iron, extra clear, safety writing glass with polished edges. Provide glass with an interlayer color coating with a durable paint/glass bond that is fade resistant, water resistant, and heat resistant.
2.1.7.2 Magnetic Glass
Provide magnetic glass markerboard writing surface composed of tempered, low-iron, extra clear, safety writing glass with polished edges and steel backing permanently adhered to the back of the glass.
2.2 PRESENTATION BOARD
Provide wall hung cabinet presentation board with lockable double doors a projection screen that pulls down over the markerboard writing surface in the cabinet interior. Attach doors to cabinet with piano hinges and include a catch or closure to keep doors closed when not in use. Provide a porcelain enamel markerboard writing surface on the interior of the cabinet with marker rail, a flip chart that can be hung on an interior door panel, and fabric covered tack surface on the interior door panels.
Provide cabinet of plastic laminate , with rectilinear edge detailing.
Dry erase markings must be removable with a felt eraser or dry cloth without ghosting. Provide each unit with an eraser and four different color compatible dry erase markers, and two keys.
2.3 MARKERBOARD
2.3.1 Porcelain Markerboard
Provide a factory assembled markerboard with a porcelain enamel, magnetic writing surface. Unit to be comprised of one piece, without joints whenever possible. When markerboard dimensions require delivery in separate sections, components must be prefit at the factory, disassembled for delivery and jointed at the site. Provide aluminum frame with marker rail constructed of the same material as the frame . The markerboard includes a map rail with a tackable insert extending the full length of the markerboard, map hooks and clips for holding sheets of paper. Provide two map hooks for each 4 feet of map rail. Dry erase markings must be removable with a felt eraser or dry cloth without ghosting. Supply each unit with an eraser and four different color compatible dry erase markers. Provide magnetic glass markerboard with 10 rare each magnets.
2.3.2 Glass Markerboards with Interlayer Color Coating
Provide markerboard with a smooth finish, magnetic glass writing surface units to be comprised of one piece, without joints whenever possible.
When markerboard dimensions require delivery in separate sections, components must be prefit at the factory, disassembled for delivery and jointed at the site. Extend marker rail the full length of the
SECTION 10 11 00 Page 7 markerboard. Marker rail is 4 inches long. The markerboard includes a map rail with a tackable insert extending the full length of the markerboard, map hooks and clips for holding sheets of paper. Provide two map hooks for each 4 feet of map rail. Dry erase markings must be removable with a felt eraser or dry erase cloth without ghosting. Supply each unit with an eraser and four different color compatible dry erase markers. Provide magnetic glass markerboard with rare earth magnets.
2.4 TACKBOARDS
Provide tackboards that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type). Provide certification or validation of indoor air quality for tackboards.
2.4.1 Cork
Provide tackboard consisting of a minimum 1/4 inch thick colored cork with burlap backing laminated to a minimum 1/4 inch thick hardboard , and aluminum frame.
2.4.2 Vinyl Covered
Provide tackboard consisting of vinyl wall covering laminated to a minimum 1/4 inch thick cork laminated to a minimum 1/4 inch thick hardboard or particleboard , and aluminum frame.
2.4.3 Fabric Covered
Provide tackboard consisting of a non-woven fabric covering laminated to a minimum 1/4 inch thick cork laminated to a minimum 1/4 inch thick hardboard or particleboard , and an aluminum frame.
2.5 BOARD CASE
Provide surface mounted board case with hinged minimum 3/16 inch thick tempered glass doors that are lockable. Provide an aluminum case with mitered corners reinforced for rigidity. Provide doors sliding aluminum "H" molding at top and bottom of case. The interior side of the back panel is tackable and composed of a minimum 1/4 inch natural cork .
Provide two keys for each unit.
2.6 DISPLAY TRACK SYSTEM
Method of display is a flexible and interchangeable system that consists of lightweight presentation components suspended from a wall mounted, linear, horizontal track. Track has two levels to attach components.
Track allows attached components to slide horizontally. Presentation components are capable of being lifted from the track and being relocated to allow for reconfiguration. Components must be capable of being installed on the track without the use of tools for installation, removal, and reconfiguration. The presentation components consist of a retractable projection screen, and display rail for setting presentation materials or a holder for displaying maps, presentation boards, drawings and other paper display materials up to a 1/4 inch thickness. Install and locate components on track in accordance with manufacturer's written recommendations. Provide markerboards with a marker rail Markerboard surface accepts magnets. Dry erase markings are removable with a felt eraser or dry cloth without ghosting. Provide each unit with an eraser
SECTION 10 11 00 Page 8 and four different color compatible dry erase markers.
2.7 INTERACTIVE WHITEBOARDS
Provide interactive whiteboards are composed of a wall mounted interactive touch screen/panel with infrared touch technology. System includes keyboard, conference camera, short throw projector , remote control, pen, and audio. Provide a system compatible with Government furnished and Government installed PC and printer. Interactive whiteboards have an electrical cord that plugs into an electrical wall outlet. Comply with electrical work requirements in Section 26 20 00 INTERIOR DISTRIBUTION
SYSTEM.
2.8 PROJECTION SCREEN
Provide wall mounted and ceiling mounted,see scope of work requirements motorized projection screen with 120V motor that is lubricated for life, quick reversal type, has overload protector, integral gears, and preset accessible limit switches. Provide recessed mounted projection screens with an operable closure door and access panel.Provide flame retardant, mildew resistant, white matte screen with white masking borders . Bottom of screen fabric is weighted with a metal rod. Provide roller of rigid metal at least 5 inches in diameter mounted on sound absorbing supports.
Motor is motor-in-roller design. Provide screen with a 3 position control switch to stop or reverse screen at any point. Install the switch in a flush electrical box with cover plate, location(s) as shown on the Electrical drawings. All conduit and wiring from the control switch to the projection screen is furnished and installed by the Contractor.
Provide ceiling recessed case of extruded aluminum . Provide wall and ceiling mounted case of aluminum . Screen is UL listed. Comply with electrical work requirements in Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Provide projection screens that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type).
2.9 COLOR
Provide finish colors for required items as specified in Section 09 06 00
SCHEDULES FOR FINISHES.
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
Location, size and mounting height of visual display units as shown on the drawings.
Mounting height is defined as distance from finished floor to top of the visual display unit frame.
3.2 INSTALLATION
Do not install items that show visual evidence of biological growth.
Perform installation and assembly in accordance with manufacturer's printed installation instructions. Use concealed fasteners. Attach visual display units to the walls with suitable devices to anchor each unit. Furnish and install trim items, accessories and miscellaneous items in total, including but not limited to hardware, grounds, clips, backing materials, adhesives, brackets, and anchorages incidental to or necessary for a sound, secure, complete and finished installation. Do not initiate
SECTION 10 11 00 Page 9 installation until completion of room painting and finishing operations.
Install visual display units in locations and at mounting heights indicated. Install visual display units level and plumb, and if applicable align doors and adjust hardware. Repair or replace damaged units as directed by the Contracting Officer.
3.3 CLEANING
Clean writing surfaces in accordance with manufacturer's cleaning instructions.
-- End of Section --
SECTION 10 11 00 Page 10
DIVISION 10 - SPECIALTIES
SECTION 10 14 00.10
EXTERIOR SIGNAGE
08/ 17, CHG 1: 11/ 18
PART 1 GENERAL
1.1 REFERENCES
1.2 GENERAL REQUIREMENTS
1.2.1 Wind Load Requirements
1.2.2 Character Proportions and Heights
1.3 SUBMITTALS
1.4 QUALIFICATIONS
1.5 DELIVERY AND STORAGE
1.6 WARRANTY
1.7 EXTRA STOCK
PART 2 PRODUCTS
2.1 MODULAR EXTERIOR SIGNAGE SYSTEM
2.1.1 Free-Standing Base Mount Pylon/Monolith Type Signs
2.1.1.1 Framing
2.1.1.2 Exterior Sheeting Panels
2.1.1.3 Mounting
2.1.1.4 Finishes
2.1.2 Panel And Post/Panel Type Signs
2.1.2.1 Posts
2.1.2.2 Panel Framing System
2.1.2.3 Panels
2.1.2.4 Finishes
2.1.2.5 Mounting
2.1.3 Changeable Letter Directories
2.1.3.1 Frame and Trim
2.1.3.2 Header Plates
2.1.3.3 Door Glazing
2.1.3.4 Door Construction
2.1.3.5 Door Locks
2.1.3.6 Fabrication
2.1.3.7 Finishes
2.1.3.8 Mounting
2.1.3.9 Changeable Letters
2.2 ILLUMINATION
2.3 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS
2.3.1 Graphics
2.3.2 Messages
2.4 METAL PLAQUES
2.4.1 Cast Metal Plaques
2.4.1.1 Fabrication
2.4.1.2 Size
2.4.1.3 Border
2.4.1.4 Background
SECTION 10 14 00.10 Page 1
2.4.1.5 Mounting
2.4.1.6 Finish
2.4.2 Chemically Etched Metal Plaques
2.4.2.1 Fabrication
2.4.2.2 Size
2.4.2.3 Finish
2.4.3 Frost and Surface Oxidized Plaques
2.4.3.1 Fabrication
2.4.3.2 Size
2.4.3.3 Finish
2.5 DIMENSIONAL BUILDING LETTERS
2.5.1 Fabrication
2.5.2 Typeface
2.5.3 Size
2.5.4 Finish
2.5.5 Mounting
2.6 ALUMINUM ALLOY PRODUCTS
2.7 ANODIC COATING
2.8 ORGANIC COATING
2.9 STEEL PRODUCTS
2.10 CAST BRONZE
2.11 VINYL SHEETING FOR GRAPHICS
2.12 GLASS
2.13 FIBER-REINFORCED POLYESTER (FRP) PANELS
2.14 ACRYLIC SHEET
2.15 POLYCARBONATE SHEET
2.16 ANCHORS AND FASTENERS
2.17 SHOP FABRICATION AND MANUFACTURE
2.17.1 Factory Workmanship
2.17.2 Dissimilar Materials
2.17.3 Shop Painting
2.18 COLOR, FINISH, AND CONTRAST
PART 3 EXECUTION
3.1 INSTALLATION
3.1.1 Anchorage
3.1.2 Protection and Cleaning
3.2 FIELD PAINTED FINISH
SECTION 10 14 00.10 Page 2
SECTION 10 14 00.10
EXTERIOR SIGNAGE
08/ 17, CHG 1: 11/ 18
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
AMERICAN WELDING SOCIETY (AWS)
AWS C1.1M/C1.1 (2012) Recommended Practices for Resistance Welding
AWS D1.1/D1.1M (2020; Errata 1 2021) Structural Welding Code - Steel
AWS D1.2/D1.2M (2014; Errata 1 2014; Errata 2 2020) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM A36/A36M (2019) Standard Specification for Carbon Structural Steel
ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products
ASTM A653/A653M (2020) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process
ASTM A924/A924M (2022) Standard Specification for General Requirements for Steel Sheet, Metallic-Coated by the Hot-Dip Process
ASTM A1011/A1011M (2018a) Standard Specification for Steel Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength Low-Alloy, High-Strength Low-Alloy with Improved
SECTION 10 14 00.10 Page 3
Formability, and Ultra-High Strength
ASTM B26/B26M (2018; E 2018) Standard Specification for Aluminum-Alloy Sand Castings
ASTM B62 (2017) Standard Specification for Composition Bronze or Ounce Metal Castings
ASTM B108/B108M (2019) Standard Specification for Aluminum-Alloy Permanent Mold Castings
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B221 (2021) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM C1036 (2021) Standard Specification for Flat Glass
ASTM D3841 (2016) Standard Specification for Glass Fiber-Reinforced Polyester Plastic Panels
ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials
NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)
NAAMM AMP 500 (2006) Metal Finishes Manual
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2020; ERTA 20-1 2020; ERTA 20-2 2020;
ERTA 20-3 2020; TIA 20-1; TIA 20-2; TIA
20-3; TIA 20-4; TIA 20-5; TIA 20-6; TIA
20-7; TIA 20-8; TIA 20-9; TIA 20-10; TIA
20-11; TIA 20-12; TIA 20-13; TIA 20-14;
TIA 20-15; TIA 20-16; ERTA 20-4 2022)
National Electrical Code
SOCIETY OF AUTOMOTIVE ENGINEERS INTERNATIONAL (SAE)
SAE AMS3611 (2011; Rev E; Stabilized (S) 2011) Plastic Sheet, Polycarbonate General Purpose
1.2 GENERAL REQUIREMENTS
All exterior signage must be provided by a single manufacturer. Exterior signage must be of the design, detail, sizes, types, and message content shown on the drawings, must conform to the requirements specified, and must be provided at the locations indicated. Submit exterior signage schedule in electronic media with spread sheet format. Spread sheet must include sign location, sign type, and message. Signs must be complete with lettering, framing as detailed, and related components for a complete installation. Each sample must consist of a complete sign panel with letters and symbols. Samples may be installed in the work, provided each sample is identified and location recorded. Submit three color samples
SECTION 10 14 00.10 Page 4 for each material requiring color and 12 inch square sample of sign face color sample.
1.2.1 Wind Load Requirements
Exterior signage must be designed to withstand ,as stated in the scop of work, mph windload. Submit design analysis and supporting calculations performed in support of specified signage.
1.2.2 Character Proportions and Heights
Letters and numbers on indicated signs for handicapped-accessible buildings must have a width-to-height ratio between 3:5 and 1:1 and a stroke-width-to-height ratio between 1:5 and 1:10. Characters and numbers on indicated signs must be sized according to the viewing distance from which they are to be read. The minimum height is measured using an upper case letter "X". Lower case characters are permitted.
1.3 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
Approved Detail Drawings; G
SD-03 Product Data
Modular Exterior Signage System
Installation
Exterior Signage; G
Wind Load Requirements
SD-04 Samples
Exterior Signage; G
SD-10 Operation and Maintenance Data
Protection and Cleaning; G
1.4 QUALIFICATIONS
Signs, plaques, and dimensional letters must be the standard product of a manufacturer regularly engaged in the manufacture of the products. Items of equipment must essentially duplicate equipment that has been in satisfactory use at least 2 years prior to bid opening.
1.5 DELIVERY AND STORAGE
Materials must be wrapped for shipment and storage, delivered to the
SECTION 10 14 00.10 Page 5 jobsite in manufacturer's original packaging, and stored in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Manufacturer's standard performance guarantees or warranties that extend beyond a one year period must be provided.
1.7 EXTRA STOCK
Provide extra interchangeable message panels and extra stock of the following: message bars of each color and size for sign types as stated in the scope of work. pressure-sensitive letters in each color and size for sign type as stated in the scope of work. changeable message strips for sign type as specified in the scope of work.
PART 2 PRODUCTS
2.1 MODULAR EXTERIOR SIGNAGE SYSTEM
Exterior signage must consist of a system of coordinated directional, identification, and regulatory type signs located where shown.
Dimensions, details, materials, message content, and design of signage must be as shown. Submit manufacturer's descriptive data and catalog cuts.
2.1.1 Free-Standing Base Mount Pylon/Monolith Type Signs
2.1.1.1 Framing
Interior framing must consist of aluminum tube columns welded to companion plates. Perimeter framing must consist of aluminum angle framing welded to the post and plate system as designed. Framing members must be designed to permit access to electrical equipment and panel removal.
Mounting must be provided as shown. Framing members of steel must be finished with semi-gloss baked enamel or two-component acrylic polyurethane. Openings must be sealed from moisture and made tamper-proof.
2.1.1.2 Exterior Sheeting Panels
Modular panels must be provided in sizes shown on drawings. Panels must be fabricated a minimum of 0.090 inch thick aluminum . Panels must be heliarc welded to framing system . Top and end panels must be removable and must be secured by 3/16 inch socket head jack nuts. Finish for metal panels must be semi-gloss baked enamel .
2.1.1.3 Mounting
Mount by securing to concrete foundation as indicated.
2.1.1.4 Finishes
Base finish must be semi-gloss baked enamel . Metal panel system finish must be baked enamel or two-component acrylic polyurethane .
2.1.2 Panel And Post/Panel Type Signs
2.1.2.1 Posts
One-piece aluminum posts must be provided with minimum 0.125 inch wall
SECTION 10 14 00.10 Page 6 thickness. Posts must be designed to accept panel framing system described. The post must be designed to permit attachment of panel framing system without exposed fasteners. Caps must be provided for each post.
2.1.2.2 Panel Framing System
Panel framing consisting of aluminum sections and interlocking track components must be designed to interlock with posts with concealed fasteners.
2.1.2.3 Panels
Modular message panels must be provided in sizes shown on drawings.
Panels must be fabricated a minimum of 0.125 inch aluminum . Panels must be designed to be interchangeable. Panels with metal return sheeting must have welded corners, ground smooth. Panels must be heliarc welded to framing system. Face panels must be removable to provide access to electrical components.
2.1.2.4 Finishes
Post finish must be semi-gloss baked enamel . Metal panel system finish must be baked enamel or two-component acrylic polyurethane .
2.1.2.5 Mounting
Provide permanent mounting by embedding posts in concrete foundation as indicated.
2.1.3 Changeable Letter Directories
2.1.3.1 Frame and Trim
Aluminum alloy finish must be anodize.
2.1.3.2 Header Plates
Header plate must consist of background metal matching frame and having raised letters attached through the back.
2.1.3.3 Door Glazing
Door glazing must be clear safety or tempered glass minimum 1/4 inch thick.
2.1.3.4 Door Construction
Door frame must be of same material and finish as surrounding frame.
Corners must be mitered , welded, and assembled with concealed fasteners.
Hinges must be standard with manufacturer, in finish to match frames and trim. Glazing must be set in frame with resilient glazing channels.
2.1.3.5 Door Locks
Door locks must be manufacturer's standard and must be keyed alike.
SECTION 10 14 00.10 Page 7
2.1.3.6 Fabrication
Frames and trim must be assembled with corners welded and mitered to hairline fit, with no exposed fasteners. Removable changeable directory panel must consist of aluminum back with vinyl covering backgrooved 1/4 inch on centers to receive letters.
2.1.3.7 Finishes
Post finish must be anodized conforming to AA DAF45 . Metal panel system finish must be anodized conforming to AA DAF45 sees scope of work, as shown.
2.1.3.8 Mounting
Directories must be mounted to supporting structures with concealed fasteners in accordance with manufacturer's instructions.
2.1.3.9 Changeable Letters
Changeable letters must be upper-case or upper and lower-case helvetica medium . Tabbed vinyl letters and numbers must be furnished in accordance with the drawings and schedule.
2.2 ILLUMINATION
Concealed lighting must be provided within panel framing members.
Lighting must be controlled by a photocell device. Top lighting must be provided by T-12 slimline lamps, 120 volt, 60-hertz, single-phase, Type 1, or Type 2 ballast . Ballast must be integrally mounted, high power factor and rated for use down to minus 20 degrees F ambient starting temperature. Ballast and wiring within the sign must be in metal raceways. Electrical equipment must be UL or FM listed and comply with NFPA 70 . Illumination must be evenly distributed. A switch on the interior of the sign must be provided to turn off power in the sign.
Switch must be readily accessible when sign is open.
2.3 GRAPHICS FOR EXTERIOR SIGNAGE SYSTEMS
2.3.1 Graphics
Signage graphics must conform to the following:
a. Custom fabricated aluminum letters, 1/4 inch thick must be provided and fastened to the message panel with concealed fasteners. Letters must project inches from face of panel.
b. Pressure sensitive precision cut vinyl letters must be provided.
2.3.2 Messages
See drawings for message content. Typeface: Helvetica medium . Type size as indicated.
SECTION 10 14 00.10 Page 8
2.4 METAL PLAQUES
Design and location of plaques must be as indicated.
2.4.1 Cast Metal Plaques
2.4.1.1 Fabrication
Cast metal plaques must have the logo, emblem and artwork cast in the flat relief technique. Plaques must be fabricated from prime aluminum .
2.4.1.2 Size
Plaque size must be as indicated.
2.4.1.3 Border
Border must be flat band .
2.4.1.4 Background
Background texture must be fine pebble .
2.4.1.5 Mounting
Mounting must be concealed .
2.4.1.6 Finish
Finishes must consist of aluminum with background sprayed dark gunmetal colored lacquer. Letters must be satin polished and entire plaque sprayed with two coats clear lacquer.
2.4.2 Chemically Etched Metal Plaques
2.4.2.1 Fabrication
Plaque must be chemically double- etched one-piece bronze 0.032 inch thick.
2.4.2.2 Size
Plaque size must be as shown.
2.4.2.3 Finish
Double-etched raised areas must be silver-tone and recessed textured areas must be silver-tone colorfilled.
2.4.3 Frost and Surface Oxidized Plaques
2.4.3.1 Fabrication
Plaque must be frosted and surface oxidized one - piece anodized aluminum inch thick.
2.4.3.2 Size
Plaque size must be as shown.
SECTION 10 14 00.10 Page 9
2.4.3.3 Finish
Material finish must be satin .
2.5 DIMENSIONAL BUILDING LETTERS
2.5.1 Fabrication
Letters must be fabricated from cast aluminum 0.090 inch aluminum sheet .
Letters must be cleaned by chemical etching or cleaned ultrasonically in a special degreasing bath. Letters must be packaged for protection until installation.
2.5.2 Typeface
Typeface must be as indicated.
2.5.3 Size
Letter size must be as indicated.
2.5.4 Finish
Baked enamel or two-component acrylic polyurethane finish must be provided.
2.5.5 Mounting
Threaded studs of number and size as recommended by manufacturer, must be used for concealed anchorage. Letters which project from the building line must have stud spacer sleeves. Letters, studs, and sleeves must be of the same material. Supply templates for mounting.
2.6 ALUMINUM ALLOY PRODUCTS
Aluminum alloy products must conform to ASTM B209 for sheet or plate, ASTM B221 for extrusions and ASTM B26/B26M or ASTM B108/B108M for castings. Aluminum extrusions must be provided at least 1/8 inch thick and aluminum plate or sheet at least 16 gauge thick. Welding for aluminum products must conform to AWS C1.1M/C1.1 .
2.7 ANODIC COATING
Anodized finish must conform to AA DAF45 as follows:
Clear (natural) designation AA-M10-C22-A31, Architectural Class II 0.4 mil or thicker.
2.8 ORGANIC COATING
Clean, prime and give surfaces a semi-gloss baked enamel finish in accordance with NAAMM AMP 500, AMP 505, with total dry film thickness not less than 1.2 mils.
2.9 STEEL PRODUCTS
Structural steel products must conform to ASTM A36/A36M. Sheet and strip steel products must conform to ASTM A1011/A1011M . Welding for steel
SECTION 10 14 00.10 Page 10 products must conform to AWS D1.2/D1.2M .
2.10 CAST BRONZE
Fabricate components with sharp corners, flat faces, and accurate profiles. Remove and polish burrs and rough spots. Finish faces to a uniform high luster. Cast bronze must be in accordance with ASTM B62.
2.11 VINYL SHEETING FOR GRAPHICS
Vinyl sheeting must be 5 to 7 year premium type and must be in accordance with the flammability requirements of ASTM E84 and must be a minimum 0.003 inch film thickness. Film must include a precoated pressure sensitive adhesive backing, Class 1, or positionable pressure sensitive adhesive backing, Class 3.
2.12 GLASS
Glass must be in accordance with ASTM C1036, Type I, Class 1, Quality q3 and ANSI Z97.1 .
2.13 FIBER-REINFORCED POLYESTER (FRP) PANELS
Fiber-reinforced polyester (FRP) must be in accordance with ASTM D3841, Type II, Grade 1, Class 124, as indicated.
2.14 ACRYLIC SHEET
Acrylic sheet must be in accordance with the flammability requirements of ASTM E84 and must conform to ANSI Z97.1 .
2.15 POLYCARBONATE SHEET
Polycarbonate sheet must conform to SAE AMS3611.
2.16 ANCHORS AND FASTENERS
Exposed anchor and fastener materials must be compatible with metal to which applied and must match in color and finish and must be non-rusting, non-corroding, and non-staining. Exposed fasteners must be tamper-proof.
2.17 SHOP FABRICATION AND MANUFACTURE
2.17.1 Factory Workmanship
Work must be assembled in the shop, as far as practical, ready for installation at the site. Work that cannot be shop assembled must be given a trial fit in the shop to ensure proper field assembly. Holes for bolts and screws must be drilled or punched. Drilling and punching must produce clean, true lines and surfaces. Welding to or on structural steel must be in accordance with AWS D1.1/D1.1M . Welding must be continuous along the entire area of contact. Exposed welds must be ground smooth.
Exposed surfaces of work must have a smooth finish and exposed riveting must be flush. Fastenings must be concealed where practical. Items specified to be galvanized must be by hot-dip process after fabrication if practical. Galvanization must be in accordance with ASTM A123/A123M and ASTM A653/A653M , as applicable. Other metallic coatings of steel sheet must be in accordance with ASTM A924/A924M . Joints exposed to the weather must be formed to exclude water. Drainage and weep holes must be included
SECTION 10 14 00.10 Page 11 as required to prevent condensation buildup.
2.17.2 Dissimilar Materials
Where dissimilar metals are in contact, or where aluminum is in contact with concrete, mortar, masonry, wet or pressure-treated wood, or absorptive materials subject to wetting, the surfaces must be protected with a coat of asphalt varnish or a coat of zinc-molybdate primer to prevent galvanic or corrosive action.
2.17.3 Shop Painting
Surfaces of miscellaneous metal work, except nonferrous metal, corrosion resisting steel, and zinc-coated work, must be given one coat of zinc-molybdate primer or an approved rust-resisting treatment and metallic primer in accordance with manufacturer's standard practice. Surfaces of items to be embedded in concrete must not be painted. Upon completion of work, damaged surfaces must be recoated.
2.18 COLOR, FINISH, AND CONTRAST
Color must be as indicated on the drawings. For buildings required to be handicapped-accessible, the characters and background of signs must be eggshell, matte, or other non-glare finish. Characters and symbols must contrast with their background - either light characters on a dark background or dark characters on a light background.
PART 3 EXECUTION
3.1 INSTALLATION
Signs, plaques, or dimensional letters must be installed in accordance with approved manufacturer's instructions at locations shown on the approved detail drawings; submit drawings showing elevations of each type of sign; dimensions, details, and methods of mounting or anchoring; shape and thickness of materials; and details of construction. A schedule showing the location, each sign type, and message must be included.
Circuits installed underground must conform to the requirements of Section 33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION. Steel conduits installed underground and illuminated signage mounted directly on buildings must be in conformance with the requirements of Section 26 20 00 INTERIOR DISTRIBUTION SYSTEM. Signs must be installed plumb and true at mounting heights indicated, and by method shown or specified. Signs mounted on other surfaces must not be installed until finishes on such surfaces have been completed. Submit manufacturer's installation instructions and cleaning instructions.
3.1.1 Anchorage
Anchorage and fastener materials must be in accordance with approved manufacturer's instructions for the indicated substrate. Anchorage not otherwise specified or indicated must include slotted inserts, expansion shields, and powder-driven fasteners when approved for concrete; toggle bolts and through bolts for masonry; machine carriage bolts for steel; lag bolts and screws for wood.
3.1.2 Protection and Cleaning
The work must be protected against damage during construction. Hardware
SECTION 10 14 00.10 Page 12 and electrical equipment must be adjusted for proper operation. Glass, frames, and other sign surfaces must be cleaned in accordance with manufacturer's instructions. After signs are completed and inspected, cover all project identification, directional, and other signs which may mislead the public. Covering must be maintained until instructed to be removed by the Contracting Officer or until the facility is to be opened for business. Submit six copies of maintenance instructions listing routine maintenance procedures, possible breakdowns and repairs, and troubleshooting guides. The instructions must include simplified diagrams for the equipment as installed. Signs must be cleaned, as required, at time of cover removal.
3.2 FIELD PAINTED FINISH
Miscellaneous metals and frames must be field painted in accordance with Section 09 90 00 PAINTS AND COATINGS. Anodized metals, masonry, and glass must be protected from paint. Finish must be free of scratches or other blemishes.
SECTION 10 14 00.10 Page 13
DIVISION 10 - SPECIALTIES
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/20
PART 1 GENERAL
1.1 REFERENCES
1.2 SUBMITTALS
1.3 EXTRA MATERIALS
1.4 QUALITY ASSURANCE
1.4.1 Samples
1.4.2 Detail Drawings
1.4.3 Sign Fabricator
1.4.4 Cybersecurity
1.5 DELIVERY, STORAGE, AND HANDLING
1.6 WARRANTY
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM
2.1.1 Panel Sign Systems
2.1.2 Modular Sign Systems
2.1.3 Standard Room Signs
2.1.3.1 Tactile Letters, Symbols and Braille
2.1.4 Directional Signs
2.1.5 Message Inserts
2.1.6 Type of Mounting for Signs
2.1.7 Character Proportions and Heights
2.2 ROOM IDENTIFICATION SIGN WITH PATIENT INFORMATION
2.2.1 Sign Faces
2.2.2 Sign Backs
2.2.3 Room Identification Tactile Letters
2.2.4 Risk Management Alert Inserts (RM)
2.2.5 Isolation Precaution Signage Inserts (IP)
2.3 STAIR SIGNAGE
2.4 EXIT DOOR TACTILE SIGN
2.5 BUILDING DIRECTORIES
2.5.1 Header Panel
2.5.2 Directory Graphics
2.5.2.1 Orientation Map
2.5.3 Doors
2.5.3.1 Door Glazing
2.5.3.2 Door Construction
2.5.3.3 Door Locks
2.5.4 Fabrication
2.5.5 Illuminated Units
2.5.5.1 Construction
2.5.5.2 Message Strips
2.5.6 Non-Illuminated Unit
2.5.6.1 Construction
SECTION 10 14 00.20 Page 1
2.5.6.2 Message Strips
2.5.7 Electronic Directory System
2.5.7.1 Hardware Requirements
2.5.7.2 Accessibility Requirements
2.5.7.3 Wayfinding Requirements
2.5.7.4 Management and Support Requirements
2.6 DOOR TAGS
2.6.1 Engraved Copy
2.7 METAL PLAQUES
2.7.1 Cast Metal Plaques
2.7.1.1 Fabrication
2.7.1.2 Border
2.7.1.3 Finish
2.7.1.4 Mounting
2.7.2 Chemically Etched Metal Plaques
2.7.2.1 Fabrication
2.7.2.2 Finish
2.8 DIMENSIONAL BUILDING LETTERS
2.8.1 Fabrication
2.8.2 Size
2.8.3 Finish
2.8.4 Mounting
2.9 PRESSURE SENSITIVE LETTERS
2.9.1 Fabrication
2.9.2 Size
2.10 MATERIALS
2.10.1 Aluminum Alloy Products
2.10.2 Anodic Coating
2.10.3 Organic Coating
2.10.4 Plastic Laminate Sheet
2.10.5 Fabrication and Manufacture
2.10.5.1 Factory Workmanship
2.10.5.2 Dissimilar Materials
2.10.6 Typeface
2.11 GRAPHICS
2.11.1 Subsurface Copy
2.12 COLOR, FINISH, AND CONTRAST
PART 3 EXECUTION
3.1 PLACEMENT SCHEDULE
3.2 INSTALLATION
3.2.1 Anchorage
3.2.2 Protection and Cleaning
SECTION 10 14 00.20 Page 2
SECTION 10 14 00.20
INTERIOR SIGNAGE
08/20
PART 1 GENERAL
1.1 REFERENCES
The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only.
ALUMINUM ASSOCIATION (AA)
AA DAF45 (2003; Reaffirmed 2009) Designation System for Aluminum Finishes
AA PK-1 (2015) Pink Sheets: Designations and Chemical Composition Limits for Aluminum Alloys in the Form of Castings & Ingot
AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
AAMA 2604 (2017a) Voluntary Specification, Performance Requirements and Test Procedures for High Performance Organic Coatings on Aluminum Extrusions and Panels
AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)
ANSI Z97.1 (2015) Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test
AMERICAN WELDING SOCIETY (AWS)
AWS D1.2/D1.2M (2014; Errata 1 2014; Errata 2 2020) Structural Welding Code - Aluminum
ASTM INTERNATIONAL (ASTM)
ASTM B209 (2014) Standard Specification for Aluminum and Aluminum-Alloy Sheet and Plate
ASTM B221 (2021) Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes
ASTM C1048 (2018) Standard Specification for Heat-Strengthened and Fully Tempered Flat Glass
ASTM D635 (2018) Standard Test Method for Rate of Burning and/or Extent and Time of Burning of Plastics in a Horizontal Position
SECTION 10 14 00.20 Page 3
INTERNATIONAL CODE COUNCIL (ICC)
ICC A117.1 (2017) Standard And Commentary Accessible and Usable Buildings and Facilities
ICC/ANSI A117.1 (2009) Accessible and Usable Buildings and Facilities
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 70 (2020; ERTA 20-1 2020; ERTA 20-2 2020;
ERTA 20-3 2020; TIA 20-1; TIA 20-2; TIA
20-3; TIA 20-4; TIA 20-5; TIA 20-6; TIA
20-7; TIA 20-8; TIA 20-9; TIA 20-10; TIA
20-11; TIA 20-12; TIA 20-13; TIA 20-14;
TIA 20-15; TIA 20-16; ERTA 20-4 2022)
National Electrical Code
NFPA 101 (2021) Life Safety Code
NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NIST)
NIST SP 800-82 (2015; Rev 2) Guide to Industrial Control Systems (ICS) Security
U.S. DEPARTMENT OF DEFENSE (DOD)
DOD 8510.01 (2020; Change 1-2020) Risk Management Framework (RMF) for DoD Information Technology (IT)
DODI 8500.01 (2014) Cybersecurity
UFC 4-010-06 (2016; with Change 1, 2017) Cybersecurity of Facility-Related Control Systems
U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA)
36 CFR 1191 Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines
1.2 SUBMITTALS
Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for information only. When used, a code following the "G" classification identifies the office that will review the submittal for the Government.
Submit the following in accordance with Section 01 33 00 SUBMITTAL
PROCEDURES:
SD-02 Shop Drawings
SECTION 10 14 00.20 Page 4
Detail Drawings; G
SD-03 Product Data
Room Identification And Directional Signage System; G
Room Identification Sign with Patient Information; G
Stair Signage; G
Exit Door Tactile Sign; G
Building Directories; G
Door Tags; G
SD-04 Samples
Interior Signage; G
Software; G
Room Identification And Directional Signage System; G
Stair Signage; G
Exit Door Tactile Sign; G
Building Directories; G
Door Tags; G
SD-10 Operation and Maintenance Data
Approved Manufacturer's Instructions; G
Protection and Cleaning; G
1.3 EXTRA MATERIALS
Provide 6 extra frames and extra stock of the following: ___6__ blank plates of each color and size for all sign types included in project_____.
Provide __6___ paper inserts and laser print templates to support end-user printing copy one___2__ copy of the software for user produced signs and inserts after project completion
1.4 QUALITY ASSURANCE
1.4.1 Samples
Submit interior signage samples of each of the following sign types showing typical quality, workmanship and color: all sign types included in project Room Identification and Directional Signage System , Stair Signage, Exit Door Tactile Sign, Door Tags, Building Directories, Metal Plaques, Dimensional Building Letters, Pressure Sensitive Letters.
Approved samples may be installed in the work, provided each sample is identified and location recorded.
SECTION 10 14 00.20 Page 5
1.4.2 Detail Drawings
Submit detail drawings showing elevations of each type of sign, dimensions, details and methods of mounting or anchoring, mounting height, shape and thickness of materials, and details of construction. Include a schedule showing the location, each sign type, and message.
1.4.3 Sign Fabricator
Sign Fabricator to follow room number strategies created by designer. The room numbering system to be reviewed and approved by the Contracting Officer and command end users during the shop drawing phase, and prior to fabrication.
1.4.4 Cybersecurity
a. The Risk Management Framework (RMF) is the process by which information systems are accredited for operation by a designated official from the Using Military Department. It is the standard process under which all DoD information systems achieve and maintain their Authority To Operate. The cybersecurity process is documented in DOD 8510.01 and NIST SP 800-82 . Refer to UFC 4-010-06 and DODI 8500.01 for additional requirements.
b. All systems that are IP addressable or interface with the Assured Network required certification to operate. Coordinate with the Government to initiate and complete the accreditation process.
c. Cybersecurity requires input from the system vendor or provider and support from the local IMD. The local IMD-IA office is the point of contact for all Cyber Security requirements. The local CMIO is the point of contact for all clinical and functional system requirements.
1.5 DELIVERY, STORAGE, AND HANDLING
Package materials to prevent damage and deterioration during shipment, handling, storage and installation. Deliver products to the jobsite in manufacturer's original packaging and store in a clean, dry area in accordance with manufacturer's instructions.
1.6 WARRANTY
Provide manufacturer's warranty to repair or replace defective interior signage materials and workmanship for a period of 2 years from date of final acceptance of the work.
PART 2 PRODUCTS
2.1 ROOM IDENTIFICATION AND DIRECTIONAL SIGNAGE SYSTEM
Provide signs, plaques, directories, and dimensional building letters that are standard products of manufacturers regularly engaged in the manufacture of such products that essentially duplicate signs that have been in satisfactory use at least 2 years prior to bid opening. Obtain signage from a single manufacturer with edges and corners of finished letter forms and graphics true and clean.
SECTION 10 14 00.20 Page 6
2.1.1 Panel Sign Systems
Provide direct print acrylic with applied tactile second surface graphics, sign is fabricated of 0.375 inch acrylic in two layers with smooth edge conforming to ANSI Z97.1 . Provide signs that can accept raised copy and Braille with printable message inserts printable message inserts. Provide paper or acetate inserts with a 0.080 inch thick non glare acrylic window to allow sign to be updated.
2.1.2 Modular Sign Systems
Provide manufactured pre-engineered component-based sign system, consisting of a combination of aluminum extrusions and injection molded parts, pre-engineered and designed to create an updatable sign system that allows for easy and inexpensive updates and changes. Provide system with incremental widths and heights that permit the assembly of multiple inserts of variable size to create a single sign. Provide a tamper-resistant sign which requires a special tool to change inserts composed of extruded aluminum for applied graphics rigid plastic for applied graphics extruded aluminum with slots for secondary inserts.
Provide continuous extruded aluminum endcaps in radius 1/8 inch thick profile. Sign inserts are required to be front loading.
2.1.3 Standard Room Signs
Provide signs that include tactile letters, symbols and Braille for interior rooms or spaces where the sign is not likely to change over time. Tactile text descriptions are required for pictograms that are provided to identify a permanent room. Examples include interior signs that label restrooms, stairs, room numbers or letters, and room names.
These permanent room signs can include paper inserts for updatable information.
2.1.3.1 Tactile Letters, Symbols and Braille
Provide ADA compliant material per 36 CFR 1191 which is raised 1/32 inch from the first…